Flow Measurement SITRANS F C

Similar documents
Flow Measurement SITRANS F C

SITRANS FC. Flowmeter SITRANS FC410

Flow Measurement SITRANS F M

Flow Measurement SITRANS F C. Flow sensor MASS 2100 DI 3 to DI 40. 4/180 Siemens FI

Flow Measurement SITRANS F M

Level Measurement Continuous level measurement Ultrasonic transmitters

Flow Measurement SITRANS F C

SITRANS F M. Flow sensor MAG 1100 F 3/59

7000 Series OPTIMASS Mass Flowmeters. Titanium Hastelloy Stainless Steel

Micro Motion F-Series Coriolis Flow and Density Meters

Flow Measurement SITRANS F M. Flow sensor MAG 1100 F 4/57

VersaFlow Coriolis 100 Mass Flow Sensor Specifications

VersaFlow Vortex 100 Vortex Flow Meter Specifications

Level Measurement Point level measurement - RF Capacitance switches

OPTIMASS 2000 Technical Datasheet

Level Measurement Point level measurement - RF Capacitance switches

OPTIMASS 3000 Technical Datasheet

Level Measurement Continuous level measurement - Capacitance transmitters

Micro Motion T-Series Coriolis Flow and Density Meters

Micro Motion ELITE Coriolis Flow and Density Meters

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application

Flow Measurement SITRANS F M. Flow sensor MAG /85. Overview

SITRANS F flowmeters SITRANS F C

Level Measurement. Continuous level measurement - Capacitance transmitters SITRANS LC500. 5/282 Siemens FI Overview.

Micro Motion F-Series Coriolis Flow and Density Meters

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.

SITRANS F C. Flow sensor MC2 4/193. Overview

SITRANS F X SITRANS FX300 3/355

Micro Motion F-Series Flow and Density Meters

Micro Motion Model D and DL Coriolis Flow and Density Meters

JUMO DELOS SI. Precision pressure transmitter with switching contacts and display. Application. Brief description. Key features.

Continuous level measurement Capacitance transmitters

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

Flow Measurement SITRANS F C

SITRANS F flowmeters SITRANS F C SITRANS F C MC2 4/169. Overview

Micro Motion R-Series Coriolis Flow and Density Meters

Micro Motion T-Series Straight-Tube Mass Flow and Density Meters. Product Data Sheet PS July 2001

SATRON VVFe Pressure Transmitter

JUMO dtrans p20. Process pressure transmitter. Brief description. Special features. Block diagram. Approvals/approval marks (see "Technical data")

LCMass Series Mass Flow Sensor

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF)

TORRIX Magnetostrictive level sensor

Micro Motion F-Series Flow and Density Meters

Flow Measurement SITRANS F C

VersaFlow Vortex 100 Vortex Flow Meter Specifications

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

Level Limit Switch liquiphant FTL 365 / FTL 366

BGN. All Metal Variable Area Flow Meter. Technical Data Sheet

Metal tube variable area flowmeter for gases, liquids and steam

RHM 12 - Standard 1 inch Coriolis Mass Flowmeter

SITRANS F C MASSFLO Practical examples of ordering. MASS2100 & MASS6000 IP67 Compact mounted

Micro Motion Model CNG050 Compressed Natural Gas Flowmeters

SITRANS T measuring instruments for temperature

Point level measurement Capacitance switches

KROHNE 10/ Optimass 70 & 71 Single Tube Coriolis Mass Flowmeters for the Pharmaceutical Industry

Level Measurement Point level measurement - RF Capacitance switches

SITRANS P measuring instruments for pressure

SITRANS P measuring instruments for pressure

Rosemount 3051T In-Line Pressure Transmitter

Rosemount 3051CFA Annubar Flowmeter

SITRANS F flowmeters SITRANS F C MASSFLO MASS MC1. 4/146 Siemens FI Overview

Level Measurement Point level measurement - Vibrating switches

RHM 04 - Universal Coriolis Mass Flowmeter with particular Fast Response

Micro Motion ELITE High Capacity Coriolis Flow and Density Meters

JUMO dtrans p20 DELTA

Ultimate Low Flow Coriolis Mass Flowmeter

A Higher Level of Performance. Data Sheet. Centurion. Guided Radar. CGR Series. For more information, please visit >

Level Measurement Continuous level measurement - Guided wave radar transmitters

Micro Motion ELITE Coriolis Flow and Density Meters

A Higher Level of Performance. Data Sheet. Centurion. Guided Radar. CGR Series. For more information, please visit >

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

Promass Q for the process industry

Magnetic-inductive flow meter EPS / UMF2. Technical data sheet

MASSMAX 1000 Series Straight twin tube Coriolis Mass Flowmeter

Flow Measurement SITRANS F M. Flow sensor MAG 5100 W. 4/68 Siemens FI Overview

Level Measurement Continuous level measurement Guided wave radar transmitters

Process Protection Motion sensors

Level Measurement Continuous level measurement - Radar transmitters

Resistance thermometer For sanitary applications Model TR22-B, for orbital welding

... PureLine PQ. Technical Specification. PureLine PQ (Disinfection) Models PQ PQ UV Chamber. Cabinet

KROHNE 10/ Optimass 70 & 71 Single Tube Coriolis Mass Flowmeters for Food & Beverage Processing

Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases

Measuring insert for resistance thermometer Model TR10-A

Micro Motion ELITE Coriolis Flow and Density Meters

Level limit switch Series RF 3000 Selection list

Process Protection Motion sensors

Micro Motion ELITE High Capacity Coriolis Flow and Density Meters

Differential pressure transmitter PASCAL Ci4 Delta P

Miniature resistance thermometer For sanitary applications Model TR21-A, with flange connection

SATRON VT Pressure Transmitter

VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries.

KROHNE 10/ Optimass 70 & 71 Single Tube Coriolis Mass Flowmeters for the Chemical Industry

CoriolisMaster FCB430, FCB450, FCH430, FCH450 Coriolis Mass Flowmeter

Micro Motion Model CNG050 Compressed Natural Gas Flowmeters

RHM40. Coriolis Mass Flow Meter for Demanding Applications. Features. Applications. Benefits

RHM 80 - Coriolis Mass Flowmeter for large flow applications optional heavy duty version

Level Probes multicap T DC 12 TE multicap T DC 11/16/21/26 TEN/TES

mass flowmeter for compressed air

Belt Scales Speed sensors

Transcription:

Overview The complete flowmeter system SITRANS FC40 can be ordered for standard, hygienic or NAMUR service. All versions can be ordered for CT service, according to OIML R 117 (Liquids other than water) and NTEP. SIL specified compact variants can be validated and configured for SIL 2 or SIL operation. SIL operation requires two flowmeters in series and monitored by a SIL-rated control system. Series mounting must not introduce cross-talk between the sensors. Refer to installation guidelines. The flowmeter is based on the latest developments within digital signal processing technology engineered for high measuring performance: Fast response to rapid changes in flow Fast dosing applications High immunity against process noise High turndown ratio of flowrates Suitable for liquid and gas service Easy to install, commission and maintain FC40 is available as standard with 4 to 20 ma analog output with HART 7.2. Additional functions can be freely configured for analog, pulse, frequency, relay or status output or binary input. The transmitter comes with a user-configurable graphical display and SensorFlash, a micro SD card for configuration backup, firmware update and data storage. The SITRANS FC40 flowmeter system consists of a SITRANS FCS400 sensor and a SITRANS FCT00 transmitter. Benefits It is compact and light, fitting neatly into dense piping arrangements Easy maintenance because modules can be exchanged rapidly Effective separation of measurement from plant vibration Highly secure operation in safety critical applications Non-volatile memory of all setup and operation data Reliable measurements due to high signal to noise ratio Secure, digital transfer of measurement data from the sensor Short overall length; easy drop-in replacement into most existing installations Functional Safety (SIL X). Device suitable for use in accordance with IEC 61508 and IEC 61511. Technical specifications Sizes DN 15 (½"), DN 25 (1"), DN 50 (2"), DN 80 (") Accuracy ±0.10% Repeatability ±0.05% Flow range (water @ 1 bar pressure loss) Architecture Display DN 15: 700 kg/h (8 157 lb/h) DN 25: 11 500 kg/h (25 5 lb/h) DN 50: 52 000 kg/h (114 640 lb/h) DN 80: 16 000 kg/h (00 000 lb/h) Compact or remote configuration Full graphical display, 240 x 160 pixels with selection of twelve languages including Chinese and Russian Power supply 20... 27 V DC ± 10%; 100... 240 V AC ± 10 %, 47... 6 Hz ± 10% Weight 4.6... 50 kg Material Sensor - Wetted parts 16L stainless steel or Hastelloy C22 - Enclosure 04 stainless steel Transmitter Aluminum with corrosion-resistant coating Enclosure rating IP67 Pressure ratings Measuring tubes -16L 100 bar (1450 psi) - Hastelloy C22 160 bar (221 psi) Sensor enclosure 20 bar (DN15, DN 25) 17 bar (DN 50, DN 80) Sensor enclosure burst pressure >160 bar (all sizes) Temperature ratings Process medium -50... +200 C (-58... +92 F) Ambient -40... +60 C (-40... +140 F) Display -20... +60 C (-4... +140 F) Process connections Flanges EN 1092-1 B1, EN 1092-1 D, ANSI/ASME B16.5, JIS B 2220, DIN 11864-2 Pipe threads ASME B1.20 (NPT), ISO228-1 G (BSPP), VCO Quick-connect Hygienic threads DIN 11851, DIN 11864-1A, ISO 285, SMS 1145 Hygienic clamps DIN 11864-A, DIN 2676, ISO 2852 Approvals Hazardous area ATEX, IECEx, EAC Ex, FM, NEPSI, CSA, INMETRO Pressure equipment PED, CRN Hygienic A, EHEDG Custody transfer OIML R 117, NTEP Operational safety (compact system only) SIL 2 Single SIL Redundant system NAMUR NAMUR-compliant (e.g. NE 21, NE 41, NE 107 and NE 12) I/O Up to 4 channels combining analog, relay or digital outputs and binary input Communication HART 7.2 EMC performance Emission EN 55011/CISPR-11 (Class A) Immunity EN/IEC 6126-1 (Industry) Mechanical load 18 to 400 Hz random The flow meter will mechanically tolerate.17 g RMS in all directions. Flow accuracy cannot be guaranteed under all conditions. /161

Ord. code SITRANS FC40 Digital coriolis flowmeter 7 ME 4 6 1 - with SITRANS FCS400 Standard flow sensor with hygienic and flange/pipe thread 7777 7-7 7 7 7 7 7 7 connections and compact or remote mounting with FCT00 transmitter Click on the for the online configuration in the PIA Life Cycle Portal. Sensor size, connection size DN 15, DN 10 (½", /8") F DN 15, DN 15 (½", ½") G DN 15, DN 20 (½", ¾") H DN 15, DN 25 (½", 1") J DN 25, DN 15 (1", ½") DN 25, DN 25 (1", 1") DN 25, DN 40 (1", 1½") DN 50, DN 40 (2", 1½") DN 50, DN 50 (2", 2") DN 80, DN 65 (", 2½") DN 80, DN 80 (", ") DN 80, DN 100 (", 4") K L N 4 B 4 C 4 J 4 K 4 L Process connection EN 1092-1 B1, PN 16 A 0 EN 1092-1 B1, PN 40 A 1 EN 1092-1 B1, PN 6 A 2 EN 1092-1 B1, PN 100 A EN 1092-1 B1, PN 160 B 1 EN 1092-1 D NUT, PN 40 A 5 EN 1092-1 D NUT, PN 6 A 6 EN 1092-1 D NUT, PN 100 A 7 EN 1092-1 D NUT, PN 160 A 8 ANSI B16.5-2009, class 150 D 1 ANSI B16.5-2009, class 00 D 2 ANSI B16.5-2009, class 600 D ANSI B16.5-2009, class 900 D 4 ISO228-1 G pipe thread E 1 ASME B1.20.1 NPT pipe thread E DIN 11851 hygienic screwed F 1 DIN 2676 hygienic Tri-Clamp G 1 DIN 11864-1A asceptic screwed H 1 DIN 11864-2A asceptic flanged H 2 DIN 11864-A clamped H ISO 2852 hygienic clamped J 1 ISO 285 hygienic screwed J 5 SMS 1145 hygienic screwed K 1 12-VCO-4 quick connect K 5 JIS B2200:2004/10K L 2 JIS B2220:2004/20K L 4 JIS B2220:2004/40K L 6 JIS B2220:2004/6K L 7 Wetted parts material AISI 16L/W1.445/W1.4404 (100 barg max.) 1 Hastelloy C22 (only for 7ME461) Calibration/Accuracy class 0.1 % flow, 5 kg/m³ density 1 0.1 % flow, 0.5 kg/m³ density 4 Standard fraction calibration 8 Transmitter/DSL material & mounting style Compact, IP67, aluminum D Remote, IP67, aluminum, M12 G Remote, IP67, aluminum, T/Box K Ord. code SITRANS FC40 Digital coriolis flowmeter 7 ME 4 6 1 - with SITRANS FCS400 Standard flow sensor with hygienic and flange/pipe thread connections and compact or remote mounting with FCT00 transmitter 7777 7-7 7 7 7 7 7 7 Ex approval Non-Ex A ATEX C IECEx F FM H CSA M NEPSI N INMETRO P KCs Q EAC U Local User Interface Blind 1 Graphical, 240 x 160 pxl Further designs Cable glands Metric, no glands Metric, plastic Metric, brass/ni plated Metric, stainless steel NPT, no glands NPT, Plastic NPT, brass/ni plated NPT, stainless steel Sofware functions and CT approvals Standard CT standard CT with NTEP I/O configuration Ch1 Ca 4... 20 ma HART active SIL certified Cp 4... 20 ma HART passive SIL certified Ca 4... 20 ma HART active Cp 4... 20 ma HART passive Options for Ex ATEX + IECEx + EAC Ex Only compact versions can be used in SIL applications. A01 A02 A05 A06 A11 A12 A15 A16 B11 B1 B52 E04 E05 E06 E07 Q0B /162

I/O configuration Ch2, Ch and Ch4 asignal,, asignal, asignal, asignal, asignal, asignal asignal, asignal, Ia asignal, asignal, R asignal, Ia, asignal, Ia, Ia asignal, Ia, R asignal, R, asignal, R, R psignal,, psignal, psignal, psignal, psignal, psignal psignal, psignal, Ip psignal, psignal, R psignal, Ip, psignal, Ip, Ip psignal, Ip, R psignal, R, psignal, R, R asignal, asignal, psignal asignal, asignal, Ip asignal, psignal, asignal, psignal, psignal asignal, psignal, Ia asignal, psignal, Ip asignal, psignal, R asignal, Ia, Ip asignal, Ip, asignal, Ip, Ip asignal, Ip, R psignal, psignal, Ia psignal, Ia, psignal, Ia, Ia psignal, Ia, Ip psignal, Ia, R Notes on I/O configurations: a or p suffix: The I/O module is selected at ordering with either active or passive function. Signal: The output can be selected for Current (0 or 4 to 20 ma), frequency or pulse function in the menu. I: Discrete status input to the flowmeter. Functions are selected in the menu including 'Freeze output', Reset totalizer'. R: Relay output for discrete status reporting. Function is selected in the menu, including 'Error', 'High flow warning'. The MLFB structure for FC40 systems must be filled to this level, including "-Z" options A.., B.., E.. and F.. F00 F40 F41 F42 F4 F44 F45 F46 F47 F50 F51 F60 F61 F62 F6 F64 F65 F66 F67 F70 F71 F80 F81 F82 F8 F84 F85 F86 F87 F90 F91 F92 F9 F94 F95 F96 F97 Add-on options and accessories Certificates Pressure test certificate CRN Pressure test certificate PED Material certificate EN 10204-.1 Welding inspection report Factory certificate to EN 10204 2.1 Factory certificate to EN 10204 2.2 Cleaning for oil and grease Cable Operating instructions for SITRANS FC40 C01 C02 C05 C07 C10 C11 C50 L50 5 m (16.4 ft), standard with M12 plugs fitted L51 5m (16.4ft), standard L52 10 m (2.8 ft) standard with M12 plugs fitted L55 10 m (2.8 ft), standard L56 25 m (82 ft), standard with M12 plugs fitted L59 25 m (82 ft), standard L60 50 m (164 ft), standard with M12 plugs fitted L6 50 m (164 ft), standard L64 75 m (246 ft), standard with M12 plugs fitted L67 75 m (246 ft), standard L68 150 m (492 ft), standard with M12 plugs fitted L71 150 m (492 ft), standard L72 Region-specific approvals and certificates South Korea (KCC) Additional data code(s) and plain text. Tag name Tag name plate, stainless steel English German A5E061511 A5E065114 W28 Y17 This device is shipped with a Quick Start guide and a CD containing further literature. All literature is available to download for free, in a range of languages, at www.siemens.com/processinstrumentation/documentation /16

Ord. code SITRANS FC40 Digital coriolis flowmeter 7 ME 4 6 2 - with SITRANS FCS400 Flow sensor 7777 7-7 7 7 7 7 7 7 Hygienic version with Ra < 0.8 m, electropolished, A approved, and compact or remote mounting with FCT00 transmitter Click on the for the online configuration in the PIA Life Cycle Portal. Sensor size, connection size DN 15, DN 10 (½", /8") F DN 15, DN 15 (½", ½") G DN 15, DN 20 (½", ¾") H DN 15, DN 25 (½", 1") J DN 25, DN 25 (1", 1") DN 25, DN 2 (1", 1¼") DN 25, DN 40 (1", 1½") DN 50, DN 40 (2", 1½") DN 50, DN 50 (2", 2") DN 80, DN 65 (", 2½") DN 80, DN 80 (", ") Process connection L M N 4 B 4 C 4 J 4 K DIN 11851 0.8 µm hygienic screwed F 1 DIN 2676 0.8 µm hygienic Tri-Clamp G 1 DIN 11864-1 0.8 µm hygienic screwed H 1 DIN 11864-2A BF-A 0.8 µm hygienic H 2 screwed (metric) DIN 11864-A BF-A 0.8 µm hygienic H clamped DIN 11864-2B BF-A 0.8 µm hygienic flanged H 4 (NPS) ISO 2852 0.8 µm hygienic clamped J 1 ISO 285 0.8 µm hygienic screwed J 5 Wetted parts material AISI 16L/1.445 (40 bar max.) 1 Calibration/Accuracy class 0.1 % flow, 5 kg/m³ density 1 0.1 % flow, 0.5 kg/m³ density 4 Standard fraction calibration 8 Transmitter/DSL material and mounting style Compact, IP67, aluminum D Remote, IP67, aluminum, M12 G Remote, IP67, aluminum, T/Box K Ex approval Non-Ex A ATEX II 2GD C IECEx GDb F FM, Class 1, Div 1 H CSA, Class 1, Zone 1 M NEPSI N INMETRO P KCs Q EAC U Local User Interface Blind 1 Graphical, 240 x 160 pxl Further designs Cable glands Metric, no glands Metric, plastic Metric, brass/ni plated Metric, stainless steel NPT, no glands NPT, plastic NPT, brass/ni plated NPT, stainless steel Sofware functions and CT approvals Standard CT standard CT with NTEP I/O configuration Ch1 Ca 4... 20 ma HART active SIL certified Cp 4... 20 ma HART passive SIL certified Ca 4... 20 ma HART active Cp 4... 20 ma HART passive Options for Ex ATEX + IECEx + EAC Ex Only compact versions can be used in SIL applications. A01 A02 A05 A06 A11 A12 A15 A16 B11 B1 B52 E04 E05 E06 E07 Q0B /164 Update 08/2016

I/O configuration Ch2, Ch and Ch4 asignal,, asignal, asignal, asignal, asignal, asignal asignal, asignal, Ia asignal, asignal, R asignal, Ia, asignal, Ia, Ia asignal, Ia, R asignal, R, asignal, R, R psignal,, psignal, psignal, psignal, psignal, psignal psignal, psignal, Ip psignal, psignal, R psignal, Ip, psignal, Ip, Ip psignal, Ip, R psignal, R, psignal, R, R asignal, asignal, psignal asignal, asignal, Ip asignal, psignal, asignal, psignal, psignal asignal, psignal, Ia asignal, psignal, Ip asignal, psignal, R asignal, Ia, Ip asignal, Ip, asignal, Ip, Ip asignal, Ip, R psignal, psignal, Ia psignal, Ia, psignal, Ia, Ia psignal, Ia, Ip psignal, Ia, R Notes on I/O configurations: a or p suffix: The I/O module is selected at ordering with either active or passive function. Signal: The output can be selected for Current (0 or 4 to 20 ma), frequency or pulse function in the menu. I: Discrete status input to the flowmeter. Functions are selected in the menu including 'Freeze output', Reset totalizer'. R: Relay output for discrete status reporting. Function is selected in the menu, including 'Error', 'High flow warning'. The MLFB structure for FC40 systems must be filled to this level, including "-Z" options A.., B.., E.. and F.. F00 F40 F41 F42 F4 F44 F45 F46 F47 F50 F51 F60 F61 F62 F6 F64 F65 F66 F67 F70 F71 F80 F81 F82 F8 F84 F85 F86 F87 F90 F91 F92 F9 F94 F95 F96 F97 Add-on options and accessories Certificates Pressure test certificate CRN Pressure test certificate PED Material certificate EN 10204-.1 Welding inspection report Factory certificate to EN 10204 2.1 Factory certificate to EN 10204 2.2 Cleaning for oil and grease Cable Operating instructions for SITRANS FC40 C01 C02 C05 C07 C10 C11 C50 L50 5 m (16.4 ft), standard with M12 plugs fitted L51 5m (16.4ft), standard L52 10 m (2.8 ft) standard with M12 plugs fitted L55 10 m (2.8 ft), standard L56 25 m (82 ft), standard with M12 plugs fitted L59 25 m (82 ft), standard L60 50 m (164 ft), standard with M12 plugs fitted L6 50 m (164 ft), standard L64 75 m (246 ft), standard with M12 plugs fitted L67 75 m (246 ft), standard L68 150 m (492 ft), standard with M12 plugs fitted L71 150 m (492 ft), standard L72 Region-specific approvals and certificates South Korea (KCC) Additional data code(s) and plain text. Tag name Tag name plate, stainless steel English German A5E061511 A5E065114 W28 Y17 This device is shipped with a Quick Start guide and a CD containing further literature. All literature is available to download for free, in a range of languages, at www.siemens.com/processinstrumentation/documentation /165

Ord. code SITRANS FC40 Digital coriolis flowmeter 7 ME 4 7 1 - with SITRANS FCS400 NAMUR complient 7777 7-7 7 7 7 7 7 7 flow sensor with flange/pipe thread connections and compact or remote mounting with FCT00 transmitter Click on the for the online configuration in the PIA Life Cycle Portal. Sensor size, Connection size DN 15, DN 6 (½", ¼") E DN 15, DN 10 (½", /8") F DN 15, DN 15 (½", ½") G DN 15, DN 20 (½", ¾") H DN 15, DN 25 (½", 1") J DN 25, DN 25 (1", 1") DN 25, DN 2 (1", 1¼") DN 25, DN 40 (1", 1½") DN 50, DN 40 (2", 1½") DN 50, DN 50 (2", 2") DN 80, DN 65 (", 2½") DN 80, DN 80 (", ") DN 80, DN 100 (", 4") L M N 4 B 4 C 4 J 4 K 4 L Process connection EN 1092-1 B1, PN 16 A 0 EN 1092-1 B1, PN 40 A 1 EN 1092-1 B1, PN 6 A 2 EN 1092-1 B1, PN 100 A EN 1092-1 B1, PN 160 B 1 EN 1092-1 D, PN 40 A 5 EN 1092-1 D, PN 6 A 6 EN 1092-1 D, PN 100 A 7 EN 1092-1 D, PN 160 A 8 ANSI B16.5, RF, class 150 D 1 ANSI B16.5, RF, class 00 D 2 ANSI B16.5, RF, class 600 D ANSI B16.5, RF, class 900 D 4 ISO228-1 G pipe thread E 1 ASME B1.20.1 NPT pipe thread E DIN 11851 Hygienic screwed F 1 DIN 2676-C (inch) Hygienic clamped G 1 DIN 11864-1 Hygienic screwed H 1 DIN 11864-2A BF-A Hygienic flanged metric H 2 DIN 11864-A Hygienic clamped H DIN 11864-2B BF-A Hygienic flanged NPS H 4 ISO 2852 Hygienic clamped J 1 ISO 285 Hygienic screwed J 5 SMS 1145 Hygienic screwed K 1 Swagelok Quick Connect K 5 JIS B2200/10K L 2 JIS B2200/20K L 4 JIS B2200/40K L 6 JIS B2200/6K L 7 Wetted parts material AISI 16L/W1.445/W1.4404 (100 barg max.) 1 Hastelloy C22 Calibration/Accuracy class 0.1 % flow, 5 kg/m³ density 1 0.1 % flow, 0.5 kg/m³ density 4 Standard fraction calibration 8 Transmitter/DSL material & mounting style Compact, IP67, aluminum D Remote, IP67, aluminum, M12 G Remote, IP67, aluminum, T/Box K Ord. code SITRANS FC40 Digital coriolis flowmeter 7 ME 4 7 1 - with SITRANS FCS400 NAMUR complient flow sensor with flange/pipe thread connections and compact or remote mounting with FCT00 transmitter 7777 7-7 7 7 7 7 7 7 Ex approval Non-Ex A ATEX II 2GD C IECEx GDb F FM, Class 1, Div 1 H CSA, Class 1, Zone 1 M NEPSI N INMETRO P KCs Q EAC U Local User Interface Blind 1 Graphical, 240 x 160 pxl Further designs Cable glands Metric, no glands Metric, plastic Metric, brass/ni plated Metric, stainless steel NPT, no glands NPT, plastic NPT, brass/ni plated NPT, stainless steel Sofware functions and CT approvals Standard CT standard CT with NTEP I/O configuration Ch1 Ca 4... 20 ma HART active, SIL certified Cp 4... 20 ma HART passive, SIL certified Ca 4... 20 ma HART active Cp 4... 20 ma HART passive Options for Ex ATEX + IECEx + EAC Ex Only compact versions can be used in SIL applications. A01 A02 A05 A06 A11 A12 A15 A16 B11 B1 B52 E04 E05 E06 E07 Q0B /166

I/O configuration Ch2, Ch and Ch4 asignal,, asignal, asignal, asignal, asignal, asignal asignal, asignal, Ia asignal, asignal, R asignal, Ia, asignal, Ia, Ia asignal, Ia, R asignal, R, asignal, R, R psignal,, psignal, psignal, psignal, psignal, psignal psignal, psignal, Ip psignal, psignal, R psignal, Ip, psignal, Ip, Ip psignal, Ip, R psignal, R, psignal, R, R asignal, asignal, psignal asignal, asignal, Ip asignal, psignal, asignal, psignal, psignal asignal, psignal, Ia asignal, psignal, Ip asignal, psignal, R asignal, Ia, Ip asignal, Ip, asignal, Ip, Ip asignal, Ip, R psignal, psignal, Ia psignal, Ia, psignal, Ia, Ia psignal, Ia, Ip psignal, Ia, R Notes on I/O configurations: a or p suffix: The I/O module is selected at ordering with either active or passive function. Signal: The output can be selected for Current (0 or 4 to 20 ma), frequency or pulse function in the menu. I: Discrete status input to the flowmeter. Functions are selected in the menu including 'Freeze output', Reset totalizer'. R: Relay output for discrete status reporting. Function is selected in the menu, including 'Error', 'High flow warning'. The MLFB structure for FC40 systems must be filled to this level, including "-Z" options A..., B..., E... and F... F00 F40 F41 F42 F4 F44 F45 F46 F47 F50 F51 F60 F61 F62 F6 F64 F65 F66 F67 F70 F71 F80 F81 F82 F8 F84 F85 F86 F87 F90 F91 F92 F9 F94 F95 F96 F97 Add-on options and accessories Certificates Pressure test certificate CRN Pressure test certificate PED Material certificate EN 10204-.1 Welding inspection report Factory certificate to EN 10204 2.1 Factory certificate to EN 10204 2.2 Cleaning for oil and grease Cable Operating instructions for SITRANS FC40 C01 C02 C05 C07 C10 C11 C50 L50 5 m (16.4 ft), standard with M12 plugs fitted L51 5m (16.4ft), standard L52 10 m (2.8 ft) standard with M12 plugs fitted L55 10 m (2.8 ft), standard L56 25 m (82 ft), standard with M12 plugs fitted L59 25 m (82 ft), standard L60 50 m (164 ft), standard with M12 plugs fitted L6 50 m (164 ft), standard L64 75 m (246 ft), standard with M12 plugs fitted L67 75 m (246 ft), standard L68 150 m (492 ft), standard with M12 plugs fitted L71 150 m (492 ft), standard L72 Region-specific approvals and certificates South Korea (KCC) Additional data code(s) and plain text. Tag name Tag name plate, stainless steel English German A5E061511 A5E065114 W28 Y17 This device is shipped with a Quick Start guide and a CD containing further literature. All literature is available to download for free, in a range of languages, at www.siemens.com/processinstrumentation/documentation /167

Flowmeter - Accessories/Spare parts Accessories CT plug Tamper cover for CT locking. Fits over the M12 plug at both sensor and transmitter ends of the remote system cable (2 pcs.) A5E1478498 Standard cable (Ex) with M12 plugs, PO insulation and PUR sleeve, blue, -40... +80 C (-40... +176 F) 5 m A5E0914929 Bag of glands (metric) in black plastic 1) A5E0907414 10 m 25 m 50 m 75 m A5E0914962 A5E0914995 A5E0915004 A5E0915074 Bag of glands, (metric) in gray plastic Ex e/i 1) A5E0907424 150 m Standard cable (Ex) for termination, PO insulation and PUR sleeve, blue, -40... +80 C (-40... +176 F) A5E0915088 Bag of glands (metric) in AISI 16 SS Ex e/i 1) Bag of glands (metric) in Ni-plated brass Ex e/i 1) A5E0907429 A5E090740 5 m A5E0914945 10 m A5E091497 25 m A5E0914984 50 m A5E0915015 Bag of glands (NPT) in black plastic 2) Bag of glands (NPT) in gray plastic Ex e/i 2) A5E090745 A5E0907451 75 m 150 m Suitcase for comprehensive sales support and training for FC40 It comes in a special suitcase with a fan implemented that allows the flowmeter to demonstrate airflow. A5E0915057 A5E0915100 A5E1467598 Bag of glands (NPT) in AISI 16 SS Ex e/i 2) Bag of glands (NPT) in Ni-plated brass Ex e/i 2) A5E0907467 A5E090747 Standard cable (non-ex) with M12 plugs, PO insulation and PUR sleeve, gray, -40...+80 C (-40... +176 F) 5 m (16.4 ft) A5E0914805 10 m (2.8 ft) A5E0914850 25 m (82ft) A5E091485 50 m (164 ft) A5E0914859 75 m (246 ft) A5E0914861 150 m (492 ft) A5E0914874 Standard cable (non-ex) for termination, PO insulation and PUR sleeve, gray, -40...+80 C (-40... +176 F) 5 m (16.4 ft) A5E09148 10 m (2.8 ft) A5E0914849 25 m (82ft) A5E0914854 50 m (164 ft) A5E0914856 75 m (246 ft) A5E0914864 150 m (492 ft) A5E091487 Suitcase for comprehensive sales support and training for FC410. It comes in a special suitcase with an S7-1200 PLC and HMI touch-screen display. The operating code is open-source and can be copied to customers to assist with system integration. Service toolkit for field maintenance of transmitter and sensor components. Contains all hand tools necessary for maintenance. Other tools may be required for installation. A5E219071 A5E0722877 /179

Flowmeter - Accessories/Spare parts Dimension Heating Jacket, indoor use, Mating parts for hygienic fittings 0... 200 C (2... 92 F) DIN 11851 max. temperature. Complete with 5 m (16.4 ft) high temperature cable fitted. Dedi- 2 unions Includes: cated plug connection to 2 mating parts (for welding in) included controller 2 EPDM gaskets 20 V AC - DN 15 electric A5E05287 DN 10 FDK:085U1016 - DN 25 electric A5E0524 DN 15 FDK:085U1017 - DN 50 electric A5E0525 DN 25 FDK:085U1019 - DN 80 electric A5E056 DN 2 FDK:085U1020 115 V AC - DN 15 electric A5E2877520 DN 40 DN 50 FDK:085U1021 FDK:085U1022 - DN 25 electric A5E2877556 DN 65 FDK:085U102 - DN 50 electric A5E2877557 Mating parts for hygienic clamp - DN 80 electric A5E2877561 ISO 2852 Heating jacket controller, IP65. Digital display for 0...200 C (2.. 92 F) control setpoint Includes: 2 clamps 2 mating parts 2 EPDM gaskets 20 V AC A5E08919 115 V AC A5E089194 1) 2 pcs M20; 1 pce M25 with single and dual cable inserts 2) 2 pcs ½" NPT; 1 pce ½" NPT with single and dual cable inserts 2 EPDM gaskets with collar for mounting set DIN 11851 25 mm FDK:085U1029 40 mm FDK:085U101 50 mm FDK:085U102 DN 10 DN 15 DN 25 DN 2 DN 40 DN 50 DN 65 FDK:085U1006 FDK:085U1007 FDK:085U1009 FDK:085U1010 FDK:085U1011 FDK:085U1012 FDK:085U101 /180

Spare parts - transmitter FCT00 Display and keypad assembly with firewire connection to the transmitter module 1) A5E0548971 Mounting bracket - FCT00; in painted aluminum for pipe or wall mounting of transmitter FCT00 remote version. Including lock ring, pressure pads and seal cap Flowmeter - Accessories/Spare parts A5E0906091 Sensor interface (Compact). Front end flow calculator and process detection. SIL approved 1) A5E0549142 M12 option for sensor housing in stainless steel. Prewired and potted to replace M12 socket in DSL housing A5E0906095 Sensor interface (Remote); barrier unit for high speed digital communication and Ex ib power supply to remote front end DSL module Display lid in painted aluminum with Ex glass plate and silicone o-ring seal Display lid in painted aluminum with FCM approved PETG polymer window (Food Contact Material) and silicone o-ring seal Transmitter cassette (active) with SIL approved 4... 20 ma output and HART 7.2 1) Transmitter cassette (passive) with SIL approved 4... 20 ma output and HART 7.2 1) Bag of loose spare parts; including cable strain relief components, mounting tool, seals and gasket, assorted screws and washers, hex cap nut, blind plugs, and o-rings Power supply 240 V AC, 47... 6 Hz 24... 90 V DC A5E0549098 A5E054944 A5E851078 A5E054957 A5E05498 A5E054996 A5E054941 M12 option - remote - in painted aluminum. Prewired and potted replacement M12 connection for FCT00 transmitter remote version Remote terminal house - M20 Remote terminal house - NPT - in painted aluminum for sensor cable termination at FCT00 transmitter remote version. Pre-wired and potted A5E0906104 A5E0906112 A5E090610 Spare parts - sensor FCS400 Blind lid in painted aluminum with o-ring A5E0549295 seal Frontend cassette Spare part frontend cassette for remote version of FC40 and cassette for FC410 1) Sensor housing metric Sensor housing NPT in painted aluminum A5E0549191 A5E05491 A5E0906080 Blind lid in painted aluminum with silicone o-ring seal I/O assembly Advise F00 to F97 from Selection and Ordering data 2) SensorFlash (micro SD card) A5E0549429 A5E099114 A5E0915258 Bag of loose parts for sensor; including cable strain A5E054924 relief components, washer, seals, o-rings, and assorted screws 1) The system firmware bundle must be stated in the "Remark" field when ordering, to ensure compatibility of the system. The FW revision is found on the product label for FC40 and FC410. Further for FC40 the firmware bundle can be found in the local display in the menu items.1.10. e.g. "2.02.01-02" 2) The I/O configuration must be stated in the "Remark" field. The I/O configuration is found in the F option of the ordering code. e.g. code F40 for ordering Ch2 Active Current/Freq/Pulse, Ch Active Current/Freq/Pulse, Ch4 Active Input Update 08/2016 /181