Operating and Maintenance Instructions. VAG LIMU-STOP Non-Return Valve

Similar documents
Installation and Operating Instructions. VAG AW Non-Return Valve

Operating and maintenance instructions VAG RETO-STOP Non-Return Valve

Operating and maintenance instructions. VAG SKR Slanted Seat Tilting Disk Check Valve

VAG CEREX 300 Butterfly Valve

VAG EKN Butterfly Valve

VAG CEREX M300 Butterfly Valve

VAG RIKO Plunger Valve

Installation and Operation Instructions. VAG ROTOP Portable Electric Drive

VAG KSSplus Hollow-Jet Discharge Valve

Operating Guide SBFV (PN16/25) ENGLISH Steel butterfly valve SBFV Page 2. Danfoss VI.IX.A1.02 1

Danfoss Butterfly Valve

VAG HYsec (F / E) Hydraulic Brake and Lift Unit

VAG Non-Return Valves

Mounting and Operating Instructions EB 5868/5869 EN

Operating manual Separator

Mounting and Operating Instructions EB 8135/8136 EN. Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil

Operating Instructions Ball Valves

Mounting and Operating Instructions EB 8222 EN. Type 3310/AT and Type 3310/3278 Pneumatic Control Valves. Type 3310 Segmented Ball Valve

Operating Instructions Garlock Butterfly Valves DN : mm / 2-24

Operating Instructions

Storage, operating and maintenance instructions for AZ plug valves and Standard valves

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

KLINGER Piston Valves KVN DN PN 16 I/III with valve ring KX-GT Modul

Keystone Figure 85/86 Check valves Installation and Maintenance Instructions

TABLE OF CONTENT. 7-Operating mechanisms of Non-return valve with hydraulic damping cylinder

series BUTTERFLY VALVE DOUBLE ECCENTRIC FLANGED FAF 3800 PRODUCTION STANDARDS DN100 DN2000 PN Design EN 593 EN ISO Flanged

Operating and installation instructions

KEYSTONE. Check valves Figure 85/86 Installation & Maintenance Instructions. Figure 85. Figure 86.

TSCHAN - TORMAX VSG. Installation and Operation Manual TSCHAN Highly flexible shaft coupling BAWE 009-GBR-0 05/2004

Flow Control. Before installation or maintenance, these instructions must be fully read and understood.

Mounting and Operating Instructions EB 8111/8112 EN. Valve Series V2001 Globe Valve Type 3321

Operating Instruction

Installation and Operating Instructions

Installation and Operating Instructions DDM-DS11 DDM-DS11-MS1 DDM-DS11-MS2

KEYSTONE OPTISEAL F14/16-15/17 AND BREWSEAL BUTTERFLY VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

INSTALLATION INSTRUCTION & TECHNICAL MANUAL FLOWMETER

Standard Valves Series Globe Valves Series Angle Valves Series Way-Valves

Globe Valve Type Fig. 1 Type 3241 Globe Valve. Mounting and Operating Instructions EB EN

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

BUTTERFLY VALVE WITH WELDED ENDS INSTALLATION AND MAINTENANCE MANUAL

Wafer and Globe Style Silent Check Valve. Operation, Maintenance and Installation Manual

KEYSTONE Figure 990/991 Butterfly valves Installation, operation and maintenance instructions

Operating and installation instructions

Operating Instructions

GT-200 GATE VALVES PN16, Screwed end

KEYSTONE SERIES 320 BUTTERFLY VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Installation, Operating & Maintenance Instructions. All-metal gate valve with compact or extended pneumatic actuator

Operating instructions GEFA / DOMINO valves series AT 200F ATEX II 1D/2DG c

Company Standard Mounting Instructions for Type Valves with Type AT Actuator

Installation, Operation, and Maintenance Manual

Operating & Maintenance Manual For Steam Conditioning Valve

USERS MA UAL Bellow sealed valve Fig.229, 230, 234, 235 Edition: 1/2008

Operating Instructions ROCO Butterfly Valve with SKG Slider-crank Mechanism, with Electric Multi-turn Actuator

back to main page Type: Butterfly valves Instructions and Operation Manual Warning! Warning! Danger for life! 1. Intended use Danger for life!

Mounting and Operating Instructions EB 5894 EN. Electric control valves with jet pump. Flanged version of valve with jet pump

Keystone Series GR resilient seated butterfly valves GRW/GRL Installation and operation manual

VAG Butterfly Valves

Technical Description Edition 2007 Mounting, maintenance and repair of propshafts with flanged universal joints

Ideal Installation. I & M Mark 67 (1/2 6 ) Control Line. Installation & Maintenance Instructions for Mark 67 Pressure Regulators

NEOTECHA NTB-NTC BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Pressure relief valve

These installation and maintenance instructions must be read in full and completely understood before the installation!

Type 2000, Operating Instructions. Bedienungsanleitung Manuel d utilisation

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Mounting and Operating Instructions EB 8039 EN. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve. Type 3351 Pneumatic On/off Valve

Installation, Operation, and Maintenance Manual

Operating and installation instructions

Medium and high pressure pumps

Mounting and Operating Instructions EB 8227 EN. Pneumatic Control Valve Type 3331/BR 31a Special version Type 3331/3278. Type 3331 Butterfly Valve

Keystone Butterfly valves ParaSeal Installation and maintenance instructions

Butterfly valves Figure 56 Installation & Maintenance Instructions

Installation and operating manual Quick closing valve (Bellow sealed) LK product no:

OPW Emergency Safety Disconnector. Safety Breakaway Coupling Type NTS-PU Series (Pull-Away) Sizes 1-4 (DN25 DN100) Page 1

Crispin Valves Operating Guide. Crispin

Installation and operating manual

Split Body Valves with Bellows Seal Series Globe Valves Series Angle Valves Series Way-Valves

Operating Instructions

Declaration of Conformity as per Directive 97/23/EC

HST -LS Interlocking device (Translation of Original Manual)

Val-Matic 3-Way Tapered Plug Valve

Operating Instructions for Elevator Buffers type LP

Mounting and Operating Instructions EB 8097 EN. Pneumatic Control Valves Type and Type

KEYSTONE. Butterfly valves Figure 9 Installation & Maintenance Instructions. Please read these instructions carefully

Mounting and Operating Instructions EB 8111/8112 EN. Series V2001 Valves Type 3321 Globe Valve

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

ACTUATOR HON

Pressure chlorine changeover unit C 7520

Mounting and Operating Instructions EB 8048 EN. Type and Type Pneumatic Control Valves Type 3249 Aseptic Angle Valve

FUNDAMENTAL SAFETY OVERVIEW VOLUME 2: DESIGN AND SAFETY CHAPTER E: THE REACTOR COOLANT SYSTEM AND RELATED SYSTEMS

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

DeZURIK 2 20" BOS BUTTERFLY VALVES

MAXIMATOR Compressors DLE 5

T R A N S L A T I O N Declaration of Conformity as per Directive 2014/68/EU

VARICOOL - V901. Injection Nozzle Valve Fig. 1

HV angle valve with single acting pneumatic actuator and closing spring (NC)

GATE VALVES. Type P (Standard: Plug) Type S (Soft Seal) Contents. (1) Be sure to read the following warranty clauses of our product 1

Installation, Operating & Maintenance Instructions. HV gate valve with pneumatic actuator. Series 110 DN mm (I. D.

2.- HANDLING OF VALVES BEFORE ASSEMBLY 3.- FITTING THE VALVE TO THE REST OF THE ASSEMBLY 5.- PERIODICAL INSPECTION OF THE VALVE AND MAINTENANCE

FPO 80 FPOC FPOS FPON, FPOS Tank truck vane pump

Diaphragm Valves Type 15

Transcription:

Operating and Maintenance Instructions VAG LIMU-STOP Non-Return Valve KAT-B 1547 Edition 1-01/2018

Table of contents 1 General 3 1.1 Safety 3 1.2 Proper use 3 1.3 Identification 3 VAG reserves the right to make technical changes and use materials of similar or better quality without express notice. The pictures used are typical and non-binding. 2 Transportation and storage 3 2.1 Transportation 3 2.2 Storage 4 3 Product and function description 4 3.1 Features, function description 4 3.1.1 LIMU-STOP IL with internal shaft 4 3.1.2 LIMU-STOP AL+HG with external shaft, lever and weight 4 3.1.3 LIMU-STOP AL+HG with external shaft, lever and weight and wire guard 4 3.2 Fields of application 4 3.3 Permissible and impermissible modes of operation 5 4 Installation into the pipeline 5 4.1 On-site requirements 5 4.2 Place of installation 5 4.2.1 Stable flow 5 4.2.2 Flow velocity 6 4.3 Installation position 6 4.4 Assembly instructions, connection fittings 7 5 Putting the valve into operation 8 5.1 Visual inspection 8 5.2 Function check and pressure test 8 6 Maintenance, servicing 8 6.1 General safety instructions 8 6.2 Inspection and operation intervals 8 6.3 Maintenance work and replacement of parts 8 6.3.1 Inspection of the disk 10 6.3.2 Leaks on the body seals 10 6.3.3 Cleaning, lubrication 10 6.3.4 Recommendations for the replacement of parts 10 7 Trouble-shooting 10 8 How to contact us 11

1 General 1.1 Safety These Operation and Maintenance Instructions must be observed and applied at all times along with the general VAG Installation and Operation Instructions for Valves (see www.vag-group.com / Category: Installation and Operation Instructions). Arbitrary alterations of this product and the parts supplied with it are not allowed. VAG will not assume any warranty or liability for consequential damage due to non-compliance with these instructions. When using this valve, the generally acknowledged rules of technology have to be observed (e.g. DIN standards, DVGW technical rules, etc.). The installation must only be carried out by qualified staff (see also Section 7.1 General safety instructions). For further technical information such as dimensions, materials or applications, please refer to the respective documentation (KAT-A 1547). VAG valves are designed and manufactured to the highest standards and their safety of operation is generally ensured. However, valves may be potentially dangerous if they are operated improperly or are not installed for their intended use. All personnel dealing with the assembly, disassembly, operation, maintenance and repair of the valves must have read and understood the complete Operating and Maintenance Instructions (Accident Prevention Regulations, regulations issued by the Trade Associations and ANSI Z535). Before removing any protective devices and/or performing work on the valves, depressurise the pipeline section and ensure it is free of hazards. Unauthorised, unintentional and unexpected actuation as well as any hazardous movements caused by stored energy (pressurised air, water under pressure etc.) must be prevented. In case of equipment that must be monitored and inspected, all relevant laws and regulations, such as the Industrial Code, the Accident Prevention Regulations, the Ordinance of Steam Boilers and instructional pamphlets issued by the Pressure Vessels Study Group must be complied with. In addition, the local accident prevention regulations must be observed. When a valve needs to be dismantled from a pipeline, fluid may emerge from the pipeline or the valve. The pipeline must be emptied completely before the valve is dismantled. Special care needs to be taken in case of residue which may continue flowing. 1.2 Proper use The VAG LIMU-STOP Non-Return Valve is a valve designed for installation into pipelines. These Installation and Operation Instructions contain important information on the safe and reliable operation of the VAG LIMU- Stop Non-Return Valve. Observing these Installation and Operation Instruction helps you to: Prevent hazards Reduce repair costs and down-times of the valve and/or the entire plant Improve the operational safety and useful life of the plant. 1.3 Identification According to DIN EN 19, all valves bear an identification label specifying the nominal diameter (DN), nominal pressure (PN) and the manufacturer s logo. A rating plate is attached to the body and contains at least the following information: VAG DN PN Manufacturer s name Nominal diameter of the valve Nominal pressure of the valve Date of manufacture 2 Transportation and storage 2.1 Transportation To transport the valve to its installation site, it must be packed in a stable, properly sized container. Ensure that the valve is protected against atmospheric influences and external damage. When the valve is shipped under specific climatic conditions (e.g. overseas transport), it must be specially protected and wrapped in plastic film and a desiccant must be added. The VAG LIMU-STOP Non-Return Valve must be transported with the disk in closed position. Preferably the valve should be placed on its inlet-side flange (see Fig. 1). The factory-applied corrosion protection and all mounted parts (e.g. lever and weight, wire guard, sensors etc.) must be specially protected. Lifting-eye nut for transportation The standard model is suitable to permit the flow of the medium in pressurised pipelines in one direction and to prevent the return flow of the medium automatically. Its technology is based on the principle of the freely swinging valve disk. For the respective technical application ranges (e.g. operating pressure, medium, temperature) please refer to the product-related documentation (KAT-A 1547). For any deviating operating conditions and applications, the manufacturer s written approval must be obtained! Picture 1: Transport position For transportation purposes and also to support assembly, lifting devices such as cables and belts must always only be attached to the lifting-eye nuts provided for transportation. The lever, weight, wire guard and sensors are not suitable for this purpose. The length and positioning of the cables/belts must ensure that the valve is in a horizontal position during the entire lifting procedure. VAG Operating and Maintenance Instructions 3

For valves that have been factory-packed in transport crates (wooden crates), the centre of gravity of the entire unit must be taken into account. The centre of gravity is marked on each side of the crate at our factory and must be considered for all lifting operations. 2.2 Storage The VAG LIMU-STOP Non-Return Valve must be stored with the disk in closed position. Preferably the valve should be placed on its inlet-side flange (see Fig. 1). The elastomeric parts (seals) must be protected against direct sunlight and/or UV light as otherwise their long-term sealing function cannot be guaranteed. Store the valve in a dry and well-aerated place. Avoid direct radiator heat. Protect any assembly units important for proper function, such as the disk or bearing, against dust and other dirt by flange protection caps or other adequate covering. Do not remove the protective caps of the connections / flanges and the packaging materials until immediately prior to assembly into the pipeline. The valve can be stored in ambient temperatures ranging from -20 C to + 50 C (protected by adequate covers). If the valve is stored at temperatures below 0 C, it should be warmed up to at least +5 C before it is installed and before it is put into operation. 3 Product and function description 3.1 Features, function description The VAG LIMU-STOP is a non-return valve in fully flanged design and can thus be installed between two flanges or used as an endof-line valve without counter-flange. 3.1.1 LIMU-STOP IL with internal shaft The non-return valve works according to the principle of function of a swing check valve operated by the medium conveyed. The disk runs on a flexible double-bearing on the lever, via a keyway connection on the disk shaft, rotatable in two bearings in the body. The entire shaft is located on the inside and pressure-tight encapsulated. 3.1.2 LIMU-STOP AL+HG with external shaft, lever and weight The non-return valve works according to the principle of function of a swing check valve operated by the medium conveyed. The disk runs on a flexible double-bearing on the lever, via a featherkey connection on the disk shaft, is rotatable iand runs on two bearings. The shaft is guided out of the body on the right in flow direction. The lever and weight unit is connected to the shaft via a featherkey connection. When the valve is delivered, it is factoryassembled for vertical installation (Figure 2); the lever with weight is positioned turned by 90 to the flow direction. 3.1.3 LIMU-STOP AL+HG with external shaft, lever and weight and wire guard The LIMU-STOP AL+HG version can be completed by a preassembled stainless-steel wire guard. All other features are the same as those of the AL+HG version. The wire guard can easily be opened via a lock and opened 180 for maintenance and inspection purposes. The cover of the wire guard is perforated so that the position of the lever is visible from the outside. 3.2 Fields of application Due to the NBR sealing materials used, the VAG LIMU-STOP Non-Return Valve is suitable for the following media: Drinking water, raw- and cooling water, domestic sewage, weak acids and alkaline solutions Oil-containing media For the respective technical application ranges (e.g. operating pressure, medium, temperature) please refer to the product-related documentation (KAT-A 1547). In case of differing operating conditions and applications, please consult the manufacturer. LIMU-STOP IL with internal shaft LIMU-STOP AL + HG with external shaft, lever and weight LIMU-STOP AL + HG + S with external shaft, lever and weight and wire guard Picture 2: Type varieties VAG Operating and Maintenance Instructions 4

3.3 Permissible and impermissible modes of operation The maximum operating temperatures and operating pressures specified in the technical documentation (KAT-A 1547) must not be exceeded. The pressure applied to the closed non-return valve must not exceed its nominal pressure. The maximum permissible flow velocity (stable flow) is that specified in the EN 1074-1 standard: For valves with a nominal pressure of PN 16, the maximum flow velocity is 4 m/s. Turbulent flow (e.g. if the valve is installed downstream of elbows) causes asymmetric flow which may lead to heavy one-sided stress acting on the bearings in the valve. For this reason, the flow velocity must be reduced accordingly (see Section 4). If this is not possible, maintenance intervals must be shorter (see Section 6). 4 Installation into the pipeline 4.1 On-site requirements When installing the valve between two pipeline flanges, these must be coplanar and in true alignment. If the pipes are not in true alignment, they must be aligned before installation of the valve, as otherwise this may result in impermissibly high loads acting on the valve body during operation, which may eventually even lead to fracture. When installing the valve into the pipeline, make sure it is tension-free. No pipeline forces must be transmitted to the valve. The space between the flanges should be wide enough to prevent damage to the coating of the raised faces of the flanges during installation. In case of works around the valve causing dirt (e.g. painting, masonry or working with concrete), the valve must be protected by adequate covering. Before putting the valve into operation, clean and purge the corresponding pipeline sections. For use with drinking water, DVGW Technical Rules W 291 and W 346 must be observed. 4.2 Place of installation The installation location of the valve must be selected so that sufficient space is provided for operation (lever and weight), later function checks and maintenance works (e.g. cleaning of the valve). If the valve is installed in the open, it must be protected against extreme atmospheric influences, such as the formation of ice, by adequate covers. To ensure the trouble-free function and long service life of the nonreturn valve, several factors have to be taken into account when positioning the valve. 4.2.1 Stable flow Subcritical and even flow ensures the vibration-free position of the disk in the flow even at higher flow velocities (see Section 3.3). To achieve subcritical flow, a straight damping zone of 5 x DN should be provided upstream of the non-return valve (Picture 3a). Should this be impossible, an installation position as shown in Picture 3b or 3c is to be preferred. If the damping zone according to Picture 3a cannot be observed, turbulences in the flow may cause the disk and bearings to vibrate and reduce their useful life. To prevent this from happening, the flow velocity should be reduced to 2 m/s max. (e.g. by choosing 5 x DN Picture 3a: Stable flow Picture 3b Picture 3c Picture 3: Stable flow VAG Operating and Maintenance Instructions 5

a valve with a larger nominal diameter) or maintenance intervals should be shortened. 4.2.2 Flow velocity The VAG LIMU-STOP Non-Return Valve is suitable for operation at the maximum flow velocity according to EN 1074-1 (see Section 3.3). This requires installation with an upstream damping zone (see Section 4.2.1, Picture 3a). weight (and optionally also the wire guard) is to be turned counterclockwise by 90 (see Picture 4.2) at the place of installation. To turn the lever with weight, only open the nut (30), pull off the lever in axial direction, turn it counter-clockwise by 90 and then reassemble it. Reassemble the nut (30) and washer (31). For the version with additional wire guard, also unfasten the cheese head screws (40), turn the wire guard (36) counter-clockwise by 90 and then reassemble it. If installation without a damping zone is inevitable, increased wear of the disk and bearings may be expected. To prevent this from happening, the flow velocity should be reduced to 2 m/s max. (e.g. by choosing a valve with a larger nominal diameter) or maintenance intervals should be shortened. If the valve is operated in sewage water containing solids and in vertical pipelines, the flow velocity selected should be as high as possible within the operation limits to prevent the valve from being clogged by deposits (see ATV-A 134). The flow velocity in vertical rising pipelines should not fall below 2 m/s. 4.3 Installation position The VAG LIMU-STOP Non-Return Valve can be installed in horizontal or rising pipelines with an angle of slope of 90 maximum (observe the flow arrow on the body of the valve!). In all other installation positions the valve is not capable of functioning (Picture 5). When the valve is delivered, it is factory-assembled for vertical installation; the lever with weight (and optionally also the wire guard) is positioned turned by 90 to the flow direction (Pictures 4.1 and 4.2). When the valve is installed in horizontal position, the lever with Picture 4.2: Reassembling the wire guard horizontal vertical When the valve is used in sewage water containing solids, the horizontal installation position should be preferred as this prevents the valve from being clogged by deposits. If the valve is operated in sewage water containing solids and in vertical pipelines, the flow velocity selected should be as high as possible within the operation limits to prevent the valve from being clogged by deposits (see ATV-A 134). The flow velocity in vertical rising pipelines should not fall below 2 m/s. horizontal vertical Picture 4.1: Installation position of the valve and position of the lever and weight VAG Operating and Maintenance Instructions 6

permissible impermissible impermissible Picture 5: Permissible and impermissible installation positions 4.4 Assembly instructions, connection fittings Check the valve for any damage that it may have suffered during transportation and storage. Protect the valve against dirt caused on the construction site by adequate covering until installation. The assembly units important for proper function, such as the disk or bearing are protected against dust and other dirt by flange protection caps. These must not be removed before the valve is installed. Prior to installation all components essential for proper function, such as the disk and bearings must be thoroughly cleaned to remove all dirt particles. VAG does not assume any liability for consequential damage caused by dirt, shot-blasting gravel residues etc. The functional parts should be checked for proper operation prior to installation. Should the valves be repainted later on, it must be ensured that no paint is applied to the functional parts. The identification plates must not be painted over either. If the equipment is sand-blasted to clean it prior to installation, these parts must be adequately covered. If solvents are used for cleaning, you should ensure that they do not destroy the seals of the pipeline or the valve. For the assembly of the VAG LIMU-STOP Non-Return Valve, it must be ensured that suitable load suspension devices as well as transportation and lifting equipment are available. To make its assembly easier, the valve is equipped with liftingeye nuts to which the transportation and lifting equipment can be attached. Fastening lifting equipment to the lever or to any other components is impermissible and may lead to damage. When connecting the valve with the pipeline flanges, hexagon bolts and nuts with washers from flange to flange must be used in the through holes. VAG Operating and Maintenance Instructions 7

Fasten the bolts evenly and crosswise to prevent unnecessary tension that may result in cracks or breaks in the flange. The pipeline must not be pulled towards the valve. Should the gap between valve and flange be too wide, this should be compensated by thicker seals. The pipeline forces transmitted to the valve must not exceed those specified by EN 1074-3. We recommend using steel-reinforced rubber seals to DIN EN 1514-1 Shape IBC. If you use raised face flanges, the use of IBC seals is mandatory. While the valve is being installed, it must be ensured that the flanges of the pipeline it is connected to are aligned and level with each other. Welding works on the pipeline must be performed before the valves are installed to prevent damage to the seals and the corrosion protection. Welding residue must be removed before the equipment is put into operation. The pipeline must be laid in a way that prevents harmful pipeline forces from being transmitted to the valve body. Should construction works near or above the valve not be completed yet, the valve must be covered to protect it from dirt. 5 Putting the valve into operation 5.1 Visual inspection Before putting the valve and the equipment into operation, perform a visual inspection of all functional parts. Check whether all bolted connections have been properly fastened. 5.2 Function check and pressure test Prior to the installation of the valve, all functional parts (disk, lever and weight) should be opened and closed completely at least once and they should be checked for ease of operation. The ease of operation of the bearing (version AL+HG) should be checked by verifying the rotation range of about 70 on the valve (Picture 6). For this purpose, lift the weight until it reaches the limit stop in open position and then drop it. The disk must fall into the seat without pressure. Caution!! The pressure exerted on the closed valve must not exceed its nominal pressure (see technical data sheet KAT-A 1547). For the pressure test of the pipeline with a test pressure exceeding the permissible nominal pressure in the closing direction of the non-return valve, slightly open the disk to prevent excessive stress from acting on the elastomeric parts. For opening the disk, e.g. a lever and weight may be used. 6 Maintenance, servicing 6.1 General safety instructions Prior to the performance of inspection and maintenance work on the valve or its assemblies, shut off the pressurised pipeline, depressurise it and secure it against inadvertent activation. During operation, the lever and weight are moved in dependence of the flow velocity and may cause injuries. Depending on the type and risk of the fluid conveyed, comply with all the necessary safety regulations! After completing the maintenance works and before resuming operation, check all connections for tightness. Perform the steps described for initial set-up specified in Section 5. 6.2 Inspection and operation intervals The condition and function of the valve should be checked at least once per year (DVGW Technical Rules W 392). In case of extreme operating conditions or heavily polluted media, the valve should be operated more frequently. The following elements should be checked: Corrosion of visible components (repair or replacement) Tightness of the shaft bushing or bearing seal towards the body Ease of operation of the disk (if necessary, disassemble it and clean and lubricate the moving parts) Seal on the disk (replace sealing ring, if necessary) 6.3 Maintenance work and replacement of parts The spare parts and wearing parts needed can be found in the KAT 1547-E spare parts list. circa 70 Picture 6: Rotation range of the disk VAG Operating and Maintenance Instructions 8

Picture 7: Single parts and item number Item Designation Material Item Designation Material 1 Body EN-JS 1030 (DCI 40) 20 O-ring NBR 2 Cover EN-JS 1030 (DCI 40) 21 O-ring NBR 3 Disk Stainless steel 1.4308 (CF8) 4 Lever Stainless steel 1.4308 (CF8) 22 Damping elements NBR 24 Stud bolt Stainless steel A4 5 Bolt Stainless steel 1.4057 25 Washer DIN 125 Stainless steel A4 7 Shaft Stainless steel 1.4057 26 Hexagon nut ISO 4032 Stainless steel A4 8 Bearing Bronze 27 Lifting-eye nut DIN 582 Stainless steel A4 9 Bearing Bronze 28 Featherkey DIN 6885 Stainless steel A4 11 Weight EN-JL 1040 (grey cast iron 25) 30 Hexagon nut ISO 4032 Stainless steel A4 13 Retaining ring Stainless steel A4 31 Washer DIN 125 Stainless steel A4 14 Sleeve Plastic 32 Cheese head screw ISO 4762 Stainless steel A4 15 O-ring NBR 33 Washer DIN 125 Stainless steel A4 16 O-ring NBR 36 Wire guard Stainless steel 1.4541 17 O-ring NBR 38 Screw plug Plastic 18 O-ring NBR 39 Flange protection cap Plastic 19 O-ring NBR 40 Cheese head screw ISO 4762 Stainless steel A4 VAG Operating and Maintenance Instructions 9

6.3.1 Inspection of the disk According to the recommended intervals, the valve should be opened and the disk cleaned. For this purpose, unscrew the cover (2) and turn the disk (3) out of the body. For version AL+GL, the lever may be used for assistance here. For the version with additional wire guard, open the door with the key provided and then fully open it by 180. When performing this working step, you can also check the bearing of the disk for ease of operation. Afterwards check the sealing ring in the disk and the sealing seat in the body for damage. Should the sealing ring be damaged, just remove it from the groove and replace it. 6.3.2 Leaks on the body seals After a longer period of operation or frequent opening of the valve, leaks on the cover seal (15) or bearing (8, 9) may occur due to material fatigue. In this case replace all worn and leaky seals. Recommended lubricant: KLÜBERSYNTH VR 69-252N (with KTW approval for drinking water) 6.3.4 Recommendations for the replacement of parts (For parts list and spare parts kits: see KAT 1547-E) a) Replacement of the disk seal (20) - every 2 years b) Replacement of the bearing seals (16, 17, 18, 19) - whenever necessary In case of extreme operating conditions, replacement intervals may be shorter than the recommended replacement intervals. 6.3.3 Cleaning, lubrication To ensure the trouble-free function of the disk and bearing, clean the valve body at the recommended intervals. The bearing as well as the suspension of the disk should be lubricated. 7 Trouble-shooting For all repair and maintenance work, please observe the general safety instructions described in Section 6.1! Problem Possible causes Remedial action Flush the valve; open cover, if necessary, Foreign particle jammed in the seat area and remove foreign particle; you can use the lever and weight to help you Disk does not seal Deposits from the medium on the seat or disk Insufficient back-pressure Seal of the disk defective Open the cover, clean the seat and the disk For complete sealing, the back-pressure should be at least 5 m water column Replace the seal (20) on the disk Wrong installation position Change installation position (cf. Section 4) Disk slamming Valve is polluted too quickly Unfavourable installation position and thus unfavourable flow on the disk (because e.g. installed too close downstream of an elbow etc.) Flow velocity of the medium too low Unfavourable installation position (e.g. vertical installation) Flow velocity of the medium too low Change installation position (cf. Section 4) Install a valve with a smaller nominal diameter or increase the flow velocity in the system Change installation position (cf. Section 4) Install a valve with a smaller nominal diameter or increase the flow velocity in the system within the operation limits of the valve Deteriorated seals Replace seals (cf. Section 6) Leaks at the body Disk operates sluggishly Leaky bearing Replace bearing seals (cf. Section 6) Cover seal leaky Replace cover seal (15) and clean the seat of the cover Not enough grease in the bearing Relubricate bearing (cf. Section 6) Bearings worn out Replace bearings (8, 9) and bearing seals; examine bearing shaft (7) and replace, if necessary VAG Operating and Maintenance Instructions 10

8 How to contact us Head office VAG GmbH Carl-Reuther-Str. 1 68305 Mannheim Germany Telephone: +49 (621) 749-0 Fax: +49 (621) 749-2153 info@vag-group.com http://www.vag-group.com Service Our service hotline can be reached 24/7 world-wide. In case of emergency, please contact us directly by phone. Service hotline: +49 621-749 2222 Service per email: service@vag-group.com www.vag-group.com info@vag-group.com Edition 1-01/2018