Thermon. SafeTrace TM. BTS Steam Tracer Product Specifications

Similar documents
Steam Tracing DESIGN GUIDE

DESIGN GUIDE FOR STEAM TRACING APPLICATIONS. THERMON The Heat Tracing Specialists

The Use of Conduction Tracers Vs Bare Tracers Metric Version

Products and Accessories. Information Guide

Specified Conventional Tube Tracers Suggested TraceBOOST Tracers

PRODUCTS&ACCESSORIES INFORMATION GUIDE SELF-REGULATING HEATING CABLES HTSXTM BSXTM VSXTM RSXTM KSRTM KSXTM

FAK-7HTS High Temperature Tubing Bundle End Seal Kit INSTALLATION PROCEDURES

Specification for Heated Instrument Tubing in Process Applications* (March 29, 2007)

HOTLINE Insulated Tubing for Steam Supply & Condensate Returns Lines

Precision engineered to the highest Australian Standards, you ll find Ardent copper fittings and coils for just about every application. Ardent.

3.0 INSULATED AND HEAT TRACED TUBING BUNDLE

Introduction to Heat Trace Cable Systems

MSC Manifolds - DIN for Steam Distribution and Condensate Collection Installation and Maintenance Instructions

Forged Steel Fittings CLASS 3000 THREADED

CHEVELLE / EL CAMINO BIG BLOCK (2 PRIMARY TUBES)

SPC-P Smart Power Connection with Temperature Monitoring Transmitter Pipe Mounted Installation Instructions

Terminator DP/FAK-2 and FAK-2L. Elbow Splice Kit for Electrically Heated TubeTrace Bundles INSTALLATION PROCEDURES

Modified polyolefin (-CR) or fluoropolymer (-CT) outer jacket

C A HEATING CABLE GLAND KIT INSTALLATION INSTRUCTIONS

TubeTrace Tubing Bundles

Design principles and Assumptions

Heat-Shrinkable Tubing

C A Heating Cable Gland Kit Installation Instructions

Pictorial Index... A-14 Introduction to Heat Trace Cable Systems Installation Examples Engineering Guide Heat Loss Tables...

ENGINEERING STANDARD FOR PROCESS DESIGN OF DOUBLE PIPE HEAT EXCHANGERS ORIGINAL EDITION JULY 1995

Power Connection Kit installation instructions

PIPE FREEZE PROTECTION AND FLOW MAINTENANCE XL-TRACE SYSTEM

6 cylinder turbocharged diesel engines for industrial applications

#281A SYNTHETIC PLUS HEAT TRANSFER OIL

Style 234 Restrained Flexible Single-Gasket Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date

Mounting and Operating Instructions EB 8111/8112 EN. Series V2001 Valves Type 3321 Globe Valve

JBM-100-STB NEMA 4X-rated connection kit Installation Instructions

INSTALLATION, SERVICE AND MAINTENANCE INSTRUCTIONS Y-FILTER 83700

INSTALLATION, SERVICE AND MAINTENANCE INSTRUCTIONS Y-FILTER 83700

JBS-100-A, A6 SINGLE ENTRY POWER CONNECTION WITH JUNCTION BOX INSTALLATION INSTRUCTIONS

Copper-Nickel Alloy for Seawater Piping Systems (CuNi 90/10)

VFD-1 Series Volt Rated IP-68 Ingress Protection Continuous 360 degree shielding

INSTALLATION, SERVICE AND MAINTENANCE INSTRUCTIONS RIGHT ANGLE FILTER Original Manual EN (0) 2019/02

Heat Shield Insulation

JBS-100-STB Single Entry Power Connection with Junction Box Installation Instructions

Polymer Insulators A Better Solution

HTSB system System overview

Keystone knife gate valves Figure OS1700

Flame Resistance, LOI 95 >

PTFE Lined Pipe and Fittings

A. This Section includes natural gas piping, specialties, and accessories within the building.

Effects of wet lubrication on Bal Seal spring-energized seal performance

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated

Southwire Company. Current Rating 70 AMPERE (60 DEG C), 85 AMPERE (75 DEG C), 95 AMPERE (90 DEG C) Ground Conductor Size

PMKG-J2LP PolyMatrix Powered Splice Kit Installation Instructions

GASOKOL vacutube. GASOKOL GmbH, vacutube_de 1 von 5

Rigid Tube and Couplings

JIS G (SGP)

Heating Cable. Cut to Length in Field. Description

PumPs. jacketed molten sulfur PumPs. Pumps Mixers Strainers Engineered Systems and Controls.

INSTALLATION GUIDELINE FOR TRYMER INSULATION ITW INSULATION SYSTEMS

HP Sanitary Sewer Pipe 12 60

Heat Exchangers (Chapter 5)

RT FlexiPanel TM Tank and Vessel Heating Panel

SERIES CVI AWWA C508 SWING CHECK VALVES 2-48

Proudly Distributed by

Full Traceability. Material Specification. Raw Material Code. Heat Treatment

Self Closing Safety Gates & Spring Assemblies. Lockinex. ea i, ea u i

Series Direct contact and metal-to-metal seating makes the T-pattern globe stop valve ideal for most shut-off applications.

ENGINEERING STANDARD FOR MACHINERY PIPING

Daikin Steam Coils. Installation and Maintenance Manual IM 901. Types HI-F5, HI-F8, & E-F5. Group: Applied Air. Part Number: IM 901

TRANSMITTER ATTACHES TO THIS SURFACE

Instrument and Heat Trace Tubing Products

Multi Orifice Nozzle. Valve (MON) R Series Control Valves R2 R3 R4 R6 R8

For the plastics machinery industry Manifold thermocouple Model TC47-MT

TUBES & PIPES SAE 6000 PSI INFORMATION GENERAL. Seamless Colddrawn AISI 316 L -Tube 211

RUBBER BELLOWS general

TECHNICAL SPECIFICATIONS

RUBBER BELLOWS TYPE 1A & 1S SERIES

NEMA 4 High Pressure High Set Point High Accuracy Pressure Switch SPECIFICATIONS

PMKG-JS POLYMATRIX SPLICE CONNECTION KIT INSTALLATION INSTRUCTIONS

Metal Thermal Materials Types Applications Testing

Pilkington Spacia revolutionary vacuum glazing The width of single glazing The warmth of double glazing

FASANI PRESSURE SEAL CAST GLOBE VALVES - STYLE B Y AND T PATTERN

M&H AWWA C508 STANDARD SWING CHECK VALVES

INSTALLATION GUIDELINE -SARAN VAPOR RETARDER FILM AND SARAN VAPOR RETARDER TAPE ITW INSULATION SYSTEMS

MSC-125 and MSC-160 Manifolds for Steam Distribution and Condensate Collection.

ACI Hoist & Crane. Festoon System. 689 S.W. 7th Terrace Dania, FL (954) Fax (954) Toll Free A-HOIST ( )

Direct contact, metal-to-metal seating, make the gate valve ideal for most shutoff applications. Class 800 ANSI.

Armor Rods. Armor Rods NOMENCLATURE GENERAL RECOMMENDATIONS

ET-PWR-END-KIT Installation Instructions (part #JSR00)

MIQ MINERAL INSULATED HEATING CABLE INSTALLATION INSTRUCTIONS

Delivering unsurpassed quality, design and value.

Type 8510 and 8510B Eccentric Disc Control Valves (EMA)

Sealon Adhesive PTFE Gasket Tape. Technical Data Sheet

For the plastics machinery industry Adjustable bayonet thermocouple Model TC47-AB

IBV Series C-LF2 Carbon Steel Inverted Bucket Vertical Steam Trap

Spring-Loaded MgO Thermocouple/ Thermowell Assemblies with Connection Heads (GP04, XP04, XP06)

TYPE ET14 TEMPERATURE REGULATOR CAST IRON, BRONZE or STEEL CONTROLS 20 to 500 F

High Voltage Copper, Smooth Aluminum Shield/Sheath

Design and Construction Standards SECTION PLUMBING PIPING

Application Note Original Instructions Development of Gas Fuel Control Systems for Dry Low NOx (DLN) Aero-Derivative Gas Turbines

Pressure Reducing Valve Type 2114/2415

SUBMERSIBLE SECONDARY CONNECTORS SSBC350-4LI. Cond. Range H W L

For the plastics machinery industry Fixed bayonet thermocouple Model TC47-FB

Transcription:

BTS Steam Tracer Application... SafeTrace BTS is a metallic tracer tube covered with a special high temperature polymer jacket. The SafeTrace BTS jacket provides a measure of personnel burn protection without sacrificing thermal performance when compared to bare metal tube tracers installed on a pipe. SafeTrace BTS tracers utilise a safety yellow identification jacket to signify materials inherently dangerous such as steam per ASME/ ANSI A3.-996. SafeTrace BTS is supplied in long length coils and may be installed anywhere bare tracing is specified. Specifications/Ratings... Available tube diameters... 3/8" & /" and 0 & Available tube materials... copper & stainless steel Typical pipe temperature range... 38 C to C Maximum exposure temperature... 5 C Minimum installation temperature... -40 C Max. recoended steam pressure... 85 kpa Benefits... Significantly reduces risk of burns Superior corrosion resistance to most acids and alkalis Lower installed costs long length coils reduce the number of tube fittings and lower maintenance costs Simple tape-on installation Quick delivery Free design assistance Construction... Copper or Stainless Steel Tube Safety Yellow Polymer Jacket. Patent pending.. does not purport to address all of the safety issues, if any, associated with the use of products when handling steam or other dangerous materials. It is the responsibility of the user to establish appropriate practices to ensure compliance with local health and safety legislation. Typical BTS Cross Section (Tracer attached to pipe with FT-H tape) 5-6.

BTS Steam Tracer Typical Steam Tracing System... Strainer Steam Tracing Materials Scope ThermoTube SafeTrace BTS Steam FAK-7 ThermoTube Steam Supply Manifold FT-H Attachment Tape SafeTrace BTS Hairpinned on Valve Trap Station To Nearest Return Point Return Manifold Product Configurations... Basic Accessories... Related Materials... Product Type BTS-3B3 BTS-4B35 BTS-3A35 BTS-4A35 BTS-3F35 BTS-4F35 BTS-0B BTS-B BTS-0A BTS-A BTS-0F BTS-F Tube Material Tube Dia. (O.D.) Wall Thickness C opper 0.03" C opper /" S S Welded S S Welded /" S S Seamless S S Seamless /" Copper Copper Welded Welded Seamless Seamless 0 0 0 FT-H...polyester fibre tape for circumferential banding of SafeTrace BTS to piping every 30 cm or as required by code or specification. Tape is 9 wide x 55 m long and has a maximum exposure temperature of 60 C. Connections between the steam and condensate headers and the SafeTrace BTS may be accomplished with ThermoTube preinsulated tubing (available in numerous configurations to meet the requirements of the application). For information on ThermoTube preinsulated tubing, refer to Form TSP0009U.. Copper tubing meets ASTM Std B68-B75. Stainless steel tubing meets ASTM Std A69.. All imperial tubes are available in 0.049" wall thickness; contact. 5-6.

SLS-IT Steam Tracer Application... SafeTrace SLS-IT is a metallic tracer tube covered with composite materials that lower thermal conductance to reduce heat output and temperature. SafeTrace provides a reduced yet predictable heat output along a traced pipe while preventing hot spots and overheating. It replaces bare metallic tracers that waste energy and stress pipe works by raising pipe temperatures much higher than desired. SafeTrace SLS-IT tracers utilise a safety yellow identification jacket to signify materials inherently dangerous such as steam per ASME/ANSI A3.-996. All SafeTrace IT tracers also comply with ASTM Std C-055, which requires that human skin temperature be less than 58 C when in contact with a hot surface for five seconds. SafeTrace SLS-IT is supplied in long length coils and may be run continuously from the steam supply manifold, along the pipe and to the condensate return manifold. 3 4 Specifications/Ratings... Available tube diameters... 3/8" & 0 Nominal O.D....9 Available tube materials... copper & stainless steel Typical pipe temperature range...4 C to 93 C Maximum exposure temperature... 5 C Minimum installation temperature... -40 C Max. recoended steam pressure... 85 kpa Skin contact temperature... <58 C 3 Construction... Copper or Stainless Steel Tube Thermal Retardant 3 Heat Reflective Tape 4 Safety Yellow Polymer Jacket Benefits... Significantly reduces risk of burns Saves up to 35% of steam consumption compared to bare metal tube Predictable heat transfer no hot spots or overheating Lower cost of ownership can be run continuously from the steam supply to the condensate collection system Simple tape-on installation Quick delivery Free design assistance. Patents pending.. does not purport to address all of the safety issues, if any, associated with the use of products when handling steam or other dangerous materials. It is the responsibility of the user to establish appropriate practices to ensure compliance with local health and safety legislation. 3. Based on operating at maximum recoended steam pressure. Temperature derived in accordance with ASTM Std C-055 and ASTM Std C-057 (skin temperature after five-second contact). Typical SLS-IT Cross Section (Tracer attached to pipe with FT-H tape) 5-6.3

SLS-IT Steam Tracer Typical Steam Tracing System... Strainer Steam Tracing Materials Scope SafeTrace SLS-IT Steam FAK-7 Steam Supply Manifold FT-H Attachment Tape SafeTrace SLS-IT Trap Station To Nearest Return Point Return Manifold Product Configurations... Basic Accessories... Product Type Tube Material Tube Dia. (O.D.) Wall Thickness SLS-IT-3B3 C opper 0.03" SLS-IT-3A35 S S Welded SLS-IT-3F35 S S Seamless SLS-IT-0B SLS-IT-0A SLS-IT-0F Copper Welded Seamless 0 0 0. Copper tubing meets ASTM Std B68-B75. Stainless steel tubing meets ASTM Std A69.. All imperial tubes are available in 0.049" wall thickness; contact. FT-H...polyester fibre tape for circumferential banding of SafeTrace SLS-IT to piping every 30 cm or as required by code or specification. Tape is 9 wide x 55 m long and has a maximum exposure temperature of 60 C. FAK-7...end termination kit contains a roll of self-vulcanising silicone rubber tape and RTV sealant (sufficient materials to waterproof approximately six terminations). No heat gun or special tools are needed for installation. The FAK-7 has a maximum exposure temperature of 04 C. 5-6.4

DLS-IT Steam Tracer Application... SafeTrace DLS-IT is a metallic tracer tube covered with composite materials that lower thermal conductance to reduce heat output and temperature. SafeTrace provides a reduced yet predictable heat output along a traced pipe while preventing hot spots and overheating. It replaces bare metallic tracers that waste energy and stress pipe works by raising pipe temperatures much higher than desired. SafeTrace DLS-IT tracers utilise a safety yellow identification jacket to signify materials inherently dangerous such as steam per ASME/ANSI A3.-996. All SafeTrace IT tracers also comply with ASTM Std C-055, which requires that human skin temperature be less than 58 C when in contact with a hot surface for five seconds. SafeTrace DLS-IT is supplied in long length coils and may be run continuously from the steam supply manifold, along the pipe and to the condensate return manifold. 3 4 Specifications/Ratings... Available tube diameters... 3/8" & 0 Nominal O.D....5 Available tube materials... copper & stainless steel Typical pipe temperature range... 5 C to 54 C Maximum exposure temperature... 5 C Minimum installation temperature... -40 C Max. recoended steam pressure... 85 kpa Skin contact temperature... <58 C 3 Construction... Copper or Stainless Steel Tube Thermal Retardant 3 Heat Reflective Tape 4 Safety Yellow Polymer Jacket Benefits... Significantly reduces risk of burns Saves up to 50% of steam consumption compared to bare metal tube Predictable heat transfer no hot spots or overheating Lower cost of ownership can be run continuously from the steam supply to the condensate collection system Simple tape-on installation Quick delivery Free design assistance. Patents pending.. does not purport to address all of the safety issues, if any, associated with the use of products when handling steam or other dangerous materials. It is the responsibility of the user to establish appropriate practices to ensure compliance with local health and safety legislation. 3. Based on operating at maximum recoended steam pressure. Temperature derived in accordance with ASTM Std C-055 and ASTM Std C-057 (skin temperature after five-second contact). Typical DLS-IT Cross Section (Tracer attached to pipe with FT-H tape) 5-6.5

DLS-IT Steam Tracer Typical Steam Tracing System... Strainer Steam Tracing Materials Scope SafeTrace DLS-IT Steam FAK-7 Steam Supply Manifold FT-H Attachment Tape SafeTrace DLS-IT Trap Station To Nearest Return Point Return Manifold Product Configurations... Basic Accessories... Product Type Tube Material Tube Dia. (O.D.) Wall Thickness DLS-IT-3B3 C opper 0.03" DLS-IT-3A35 S S Welded DLS-IT-3F35 S S Seamless DLS-IT-0B DLS-IT-0A DLS-IT-0F Copper Welded Seamless 0 0 0. Copper tubing meets ASTM Std B68-B75. Stainless steel tubing meets ASTM Std A69.. All imperial tubes are available in 0.049" wall thickness; contact. FT-H...polyester fibre tape for circumferential banding of SafeTrace DLS-IT to piping every 30 cm or as required by code or specification. Tape is 9 wide x 55 m long and has a maximum exposure temperature of 60 C. FAK-7...end termination kit contains a roll of self-vulcanising silicone rubber tape and RTV sealant (sufficient materials to waterproof approximately six terminations). No heat gun or special tools are needed for installation. The FAK-7 has a maximum exposure temperature of 04 C. 5-6.6

SnapTrace TM Heat Transfer Compound Application... SnapTrace is a preformed flexible heat transfer compound designed for rapid, consistent installation on straight piping runs with outer diameters of 40 and larger. s heat transfer compounds provide an efficient thermal connection between the tracer and the process equipment. By eliminating the air voids that would ordinarily exist, heat is directed into the pipe wall primarily through conduction rather than convection and radiation. A single tracer utilising s heat transfer compound has the equivalent performance of three to five air convection (bare) tracers. SnapTrace includes TFK galvanised steel channel, providing mechanical and weather protection to the installation. Refer to the back of this specification sheet for details. Specifications/Ratings... Standard size... preformed. m sections Maximum exposure temperature... 08 C Minimum exposure temperature... -73 C Minimum installation temperature... - C Heat transfer coefficient, U... tracer to pipe wall 4-7 W/m C Electrical resistivity... 57 Ohm/cm Shelf life... indefinite Bond shear... 689-034 kpa Water-soluble... no Benefits... Factory-formed to fit the tracer and pipe Installs five times faster than hand trowel compounds Nonsoluble in water No surface preparation required No curing required Increases heat transfer rates significantly over bare tracing Free design assistance Note.... If under normal conditions heat transfer fluids are below 93 C, a four-hour start-up procedure should be implemented to circulate fluids > 93 C through the tracers. Description... SnapTrace sections are shipped in. m lengths and are packaged 5 sections per box. Each SnapTrace order includes protective galvanised steel channel. SnapTrace is nonsoluble in most liquids and requires no curing procedures when the heating medium is at or above 93 C. Typical Installed Cross Section (ChannelTrace TM system) 5-6.7

SnapTrace TM Heat Transfer Compound Typical Steam Tracing System... Strainer Steam Tracing Materials Scope ThermoTube SnapTrace with TFK Channel Steam FAK-7 Tracer Tube ThermoTube Steam Supply Manifold T34PB-CR TB T-80 or T-85 Trap Station To Nearest Return Point Return Manifold Product Configurations... Basic Accessories... Product Type Description ST- Fits 0 O.D. Tracer Tubing for Nominal Pipe Sizes 40 or Larger ST- ST-3 ST-4 ST-5 ST-6 Fits O.D. Tracer Tubing for Nominal Pipe Sizes 40 or Larger Fits 0 O.D. Tracer Tubing for Nominal Pipe Sizes 80 or Larger Fits DN 5 or / inch NPS Pipe Tracers for Nominal Pipe Sizes 80 or Larger Fits DN 0 or 3/4 inch NPS Pipe Tracers for Nominal Pipe Sizes 50 or Larger Fits DN 5 or inch NPS Pipe Tracers for Nominal Pipe Sizes 50 or Larger TFK-4...galvanised steel channel 3 x covers SnapTrace heat transfer compound applied to 0 and O.D. tube tracers. TFK-7...galvanised steel channel 43 x 3 covers SnapTrace heat transfer compound applied to 0 O.D. tube and DN 5 (/ inch NPS) pipe tracers. TFK-9...galvanised steel channel 64 x 44 covers SnapTrace heat transfer compound applied to 5 O.D. tube and DN 0 or 5 (3/4 or inch NPS) pipe tracers. Stainless Steel Banding...used to secure tracer, compound and channel to piping. TB ( wide, 0,5 thick) for 0 and O.D. tube tracers. T3B ( wide, 0,8 thick) for 0 or 5 O.D. tube and DN 0 or 5 (3/4 or inch NPS) pipe tracers. C00...banding tool for applying tension to TB or T3B banding. 950A...crimping tool for T34PB-CR seals. T34PB-CR...crimp seals for fastening tensioned banding. 5-6.8