Predator Medium Floodlight Wet Location

Similar documents
Prismpack V, Prismalume V, Large Prismpack, Large Prismalume

IMPORTANT SAFETY INSTRUCTIONS

LED IMPORTANT SAFETY INSTRUCTIONS

LED IMPORTANT SAFETY INSTRUCTIONS

Variety of mounting methods. UL, CUL, and CSA listed for general and hazardous locations

1000 Watt Metal Halide Flood Light - 110,000 Lumens - Slipfitter Mount - 120~277 Volts AC

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION

Areamaster 100 Wide-Beam Floodlights 70 W, 100 W, 150 W HPS; 70 W, 100 W, 150 PSMH For general, marine and hazardous locations.

1000 Watt Metal Halide Light - Class 1 Division 2 Groups A-D - T3b Temperature - 110,000 lumens

SOURCE TE- Electronic MH. OPTIONS See Below OPTIONS. L = Lamped BLANK = General Purpose Optics A = Asymmetric Optics S = Spot

220/230/240V Watt High Pressure Sodium - Hazardous Location Lighting - C1D2 - Pole Mount

Areamaster 1000 Floodlights Integrally Ballasted W HID For hazardous locations.

LED IMPORTANT SAFETY INSTRUCTIONS

Saturn Cutoff. Order Code: Pole Order Code: Series Height Finish Options. Customer: Date: Project: Qty: Type: SAC Saturn Cutoff SAC

FL SeriesFL100 FL25 FL50 FL200. Architectural Spot and Flood Light INSTALLATION GUIDE

AFL FLOODLIGHT SERIES

Overall Dimensions. Specifications

FL Series FL100 FL50. Architectural Spot and Flood Light INSTALLATION GUIDE

Installation Instruction ALG Series LED Area Light Version: 3.1

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION.

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION

Areamaster LED Flood/High Bay Luminaires

TOYOTA 4-RUNNER KIT 5 KIT

ORDERING INFORMATION: 120 Volts (120)

LED IMPORTANT SAFETY INSTRUCTIONS

GENUINE Interior Lighting Kit

AquaLumin III - Nicheless Light Installation Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Installation Instructions

Installation Instructions QUICKSILVER CONSOLE SHIFTER Fits: Chevelle / El Camino

LED IMPORTANT SAFETY INSTRUCTIONS

Lantern Era Bollard - LE Installation Instructions

Mfg. No: A Watt Brute Portable Generator

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION.

Illustrations on the manual are for installation purposes only. It may not be identical to the fixture purchased.

INSTALLATION AND PARTS MANUAL MODEL 30B FOR NEW HOLLAND DC75, DC85, DC95X

DEFENDER SERIES. 5 Gallon, Double Walled, Field Replaceable Spill Container Model Series INSTALLATION, OPERATION, & MAINTENANCE

HAZARDOUS LOCATION STREET LIGHT SLA SERIES INSTALLATION INSTRUCTIONS

SURFACE/CEILING & SUSPENDED MOUNT INSTALLATION

SLXP Series ! CAUTION. Cord Plug. Cord Replacement. Installation Instructions

Overall Dimensions. Specifications

General Installation Instructions LED

EEQ SERIES COMPACT FLUORESCENT EMERGENCY FACTORY SEALED LIGHTING FIXTURES

INSTALLATION INSTRUCTIONS

GENUINE MUD FLAP (FRONT)

GENUINE PARTS INSTALLATION INSTRUCTIONS

Technical Support (707)

SAFETY THIS PRODUCT IS FOR OFFROAD USE ONLY. ALL LIABILITY FOR INSTALLATION AND USE RESTS WITH THE OWNER.

NOTE: Refer to hardware list provided to identify fasteners supplied. Figure 2-1

Installation Instructions. QuickSilver Shifter. Fits: GM, Ford, Chrysler Transmissions See Application Guide for Specific Applications Part # 80683

1PC TONNEAU COVER INSTALLATION INSTRUCTIONS IMPORTANT

Non-Metallic Weatherproof Boxes, Covers and Lampholders

OWNER'S MANUAL MOBILE LIFT:

General Installation Instructions LED

City of Ottawa Street Lighting. HID Shoebox Style Luminaire

Self-Stabilizing Hand Truck Table of Contents:

OSQ Series IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. LED Area Light TO INSTALL:

This suspension system was developed using a Maximum tire size of 33 X 12.5 with a 17 x 9 aftermarket wheel with 4 1/2-5 backspacing..

LED Area Light. This is the fixture of choice for all of our dealerships. Contact Us:

Technical Support (707)

SKILL ATTACK PITCHING MACHINE PATENTS APPLIED FOR INSTRUCTION MANUAL. Includes: OPERATION SETUP USE & CARE SERVICE

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

INSTALLATION INSTRUCTION 88088

Ritorno Square Asymmetrical LED

INSTALLATION AND PARTS MANUAL

LED Decorative Highbay

H700 H710 H720. Compact Flood. Typical Applications. Features. Lamp Types. Approvals SPECIALTY LANDSCAPE

It don t mean a thing If it ain t got the swing

09-UP FORD F150 6 LIFT KIT

"Engineered to Ride, Built to Last "

INSTALLATION & OWNER S MANUAL

Instructions for 2-row monitoring only

TOYOTA TUNDRA COLD AIR INTAKE Preparation SEQUOIA

GENUINE PARTS INSTALLATION INSTRUCTIONS

Installation Guide for HP3 & HP4 ANTENNAS

GENUINE CARGO NET INSTALLATION AND USER S INSTRUCTIONS

Checker Unload Checkstand Installation Instructions

MaxLite StaxMax LED Flood Lights

LEDMPAL15 15 Watt Multi-Purpose LED Area Light

LED Area Light. scratch that. This is the fixture of choice for all of our dealerships. Contact Us:

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

SE400-M3-MMO-100/(U)SLQ-32A(V)3 WARNING. b. Engage swingbolts 3A11H9 with SRU front panel support hooks H1 and tighten nuts on swingbolts.

SAVE THESE INSTRUCTIONS!!

TESLA MODEL S REAR UNDER SPOILER & DIFFUSER SYSTEM

Installation Instructions BLTR and 2BLTR Relight Assembly

Installation Instructions 2019 Chevy and GMC 1500 Rear Bumper Product Number: E4050, E4051 Application: Chevy and GMC 1500 Trucks

FRONT & 4 REAR GM WD LOWERING KIT

INSTALLATION & OWNER S MANUAL

INSTALLATION INSTRUCTIONS

09-13 FORD F150 4 LIFT KIT

INSTALLATION INSTRUCTIONS SEMI-HIDDEN WINCH MOUNT Part Number:70005 Application: Ford Super Duty

3000 Watt Pneumatic Light Tower - Extends to 18 Feet - Three 1000W Metal Halide Lamps

Installation Documentation ID-2663

INSTALLATION & OWNER S MANUAL

ENDURALUME HL /02

09-UP F150 2WD 6 LIFT KIT

INSTALLATION INSTRUCTIONS

Contents. Section 5: Adjustments Ball Detect Adjustment Transport Band Tension Adjustment

MODEL T TON FLOOR JACK w/led LIGHT INSTRUCTIONS

Taxonomies, Classifications, and Categories WHITE POWDER COATED DIE CAST ALUMINUM GUARD

Suspension System RS6582B

Transcription:

Predator Medium Floodlight Wet Location Installation and Maintenance Manual AFTER INSTALLATION DELIVER THIS MANUAL TO OWNER IMPORTANT SAFETY INSTRUCTIONS -READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL OR MAINTAIN THIS FIXTURE. WORK MUST BE DONE BY QUALIFIED PERSONNEL. -BE CERTAIN THAT ALL ELECTRICAL POWER IS DISCONNECTED FROM THE FIXTURE BEFORE INSTALLING OR MAINTAINING THE FIXTURE. -FOLLOW LAMP MANUFACTURER'S OPERATING AND MAINTENANCE INSTRUCTIONS. FAILURE TO FOLLOW THESE S MAY RESULT IN DEATH, INJURY OR SIGNIFICANT PROPERTY DAMAGE. - Doors can be replaced as units and repaired in a shop under protected conditions. -The reflector located within the housing can be replaced as needed. Different types of reflectors will provide different light distributions. 1.2 Alternate Information Sources. If additional questions arise relative to the Predator floodlight that this document or your supplier cannot answer please refer them to: Holophane, Field Service Department P.O. Box 3004 Newark, OH 43058-3004 866-759-1577 2. INSTALLATION 2.1 Tools and Materials Required. The following tools and materials are required during installation of the Predator floodlight: Table 1. Installation Tools and Materials DESCRIPTION USE 3/8" hex head socket wrench Captive door screws 3/4" hex head wrench Yoke bolt 1/2" hex head wrench Box Mount 9/16 hex head socket wrench Knuckle fitter bolt and set screw Pliers Cord grip (if applicable) Torque wrench Captive door screws, set (inch and foot lbs) screws and bolts Wire nuts 2.2 Yoke Mount Installation. 1. INTRODUCTION GR421 2.2.1 Bolt the yoke to the mounting structure using either two 3/8" bolts or one 1/2" grade 5 bolt. Tighten bolts securely (30-35 ft. lbs. for 3/8" bolts or 50-60 ft. lbs. for 1/2" bolt). These bolts are not provided. 2.2.2 Loosen the captive door screws attaching the door to the See Figure 1. 2.2.3 Detach the power disconnect plug from the disconnect 2.2.4 If needed, remove the door by removing the cotter pin from 1.1 Product Description. The Predator floodlights have been designed and tested in accordance with UL1572. These floodlights are suitable for use in wet locations. - The floodlight model size is referred in Figure 1. - Major components of the floodlight are identified in Figure 1. - The Predator floodlights have been designed to allow permanent installation of the yoke or knuckle fitter or box mount and housing while still providing easy maintenance and repair. - The lamp, all electrical components, and the reflector can be accessed by opening the door. - Using a socket wrench, the door can be opened by loosening captive door screws. - All electrical components and the lens are contained on the door and the door can be removed easily and without tools (once the captive door screws are loosened). NOTE POWER CORD FITTING The threaded hole in the back of the housing is tapped for 1/2-14 NPT. 2.2.5 Use UL approved watertight power cord fittings (not provided) on all installations where fittings are required. 2.2.6 Remove clear protective cover and install watertight fitting. Tighten securely. 2.2.7 Make all wiring connections in accordance with approved connections are retained between the folds of the wire shield in the housing. 2.2.8 If the door was removed as in 2.2.4 reinstalll the door by IM-62-E

Figure 1 W H D Weight 16-7/8" 22-3/4" 10-1/2" 46 lbs. GR420 Figure 2 2.2.9 Insert the door disconnect plug into the disconnect receptacle 2.2.10 Securely install the proper lamp. 2.2.11 Close the door. Thread the captive door screws into the housing. Tighten the captive door screws to 55 in. lbs. torque. This is required for watertight door seal. 2.2.12 Aim the floodlight restricting mounting to + 90 o from vertical lamp base down. 2.2.13 Tighten the 1/2" diameter yoke bolts securely (approx. 50 ft.lb. recommended). 2.2.14 Energize the floodlight. Check its operation and for proper area illumination. Adjust the aiming point as needed but within the limits of the mounting restrictions. 2.3 Knuckle Fitter Mount Installation. 2.3.1 Slip the slip fitter of the knuckle fitter over the pole-top, tenon or pipe bracket. Lightly tighten all four set screws evenly against the pole-top, tenon or pipe bracket. DO NOT MOUNT THE KNUCKLE FITTER TO A TENON OR BRACKET THAT IS MORE THAN 30 DEGREES FROM VERTICAL. MOUNTING AT AN ANGLE GREATER THAN 30 DEGREES MAY RESULT IN DISENGAGEMENT OF THE FITTER AND RESULT IN SERIOUS INJURY OR DEATH. 2.3.2 Loosen the captive door screws attaching the door to the 2.3.3 Detach the power disconnect plug from the disconnect 2.3.4 If needed, remove the door by removing the cotter pin from GR509B 2.3.5 Make all wiring connections in accordance with approved connections are retained between the folds of the wire shield in the housing. 2.3.6 If the door was removed as in 2.3.4 reinstalll the door by 2.3.7 Insert the door disconnect plug into the disconnect receptacle 2.3.8 Securely install the proper lamp. 2.3.9 Close the door. Thread the captive door screws into the housing. Tighten the captive door screws to 55 in. lbs. torque. This is required for watertight door seal.

2.3.10 Aim the floodlight restricting mounting to + 90 o from vertical lamp base down. 2.3.11 Tighten the 3/8" diameter knuckle fitter bolt securely (approx. 16 ft.lb. recommended). Tighten (4) 3/8 set screws to 16 ft. lbs. See Figure 2. 2.3.12 Energize the floodlight. Check its operation and for proper area illumination. Adjust the aiming point as needed but within the limits of the mounting restrictions. Figure 3 2.4 Box Mount Installation. 2.4.1 Mount the thru-way box to the mounting structure using 3/8" fasteners (not provided). 2.4.2 Loosen the captive door screws attaching the door to the 2.4.3 Detach the power disconnect plug from the disconnect 2.4.4 If needed, remove the door by removing the cotter pin from 2.4.5 Use UL approved watertight fittings (not provided) on all installation. 2.4.6 Remove clear protective cover and install watertight fitting. Tighten securely. 2.4.7 Mount unit to cast box with the four 5/16 hex bolts with lockwashers supplied. The steel reinforcing plate must be installed inside the housing as shown in Figure 3. Be sure to install the gasket between box and unit supplied. Tighten bolts securely (approximately 15 ft. lbs.) 2.4.8 Make all wiring connections in accordance with approved connections are retained between the folds of the fiber heat shield 2.4.9 If the door was removed as in 2.4.4, reinstall the door by 2.4.10 Insert the door disconnect plug into the disconnect 2.4.11 Securely install the proper lamp type. 2.4.12 Close the door. Thread the captive door screws into the housing. Tighten captive door screws to 55 in. lbs. torque. This is required for water tight door seal. 2.4.13 Refer to the identification label on the unit for mounting restrictions. 2.4.14 Energize the floodlight. Check its operation and for proper area illumination. 3. MAINTENANCE 3.1 Relamping and cleaning. 3.1.1 Deenergize the floodlight. 3.1.2 Wipe off the exterior of floodlight to remove dirt or debris that could enter when the door is opened. 3.1.3 Loosen the captive door screws attaching the door to the 3.1.4 Remove the lamp. 3.1.5 Securely install a proper new lamp. 3.1.6 Wash both sides of the lens. GR419 3.1.7 Check the condition of the door gasket and seal area on the housing. Ensure that no damage exists that could affect seal integrity. 3.1.8 Check the interior of the housing and door for evidence of damage or potentially hazardous conditions. FOR REPLACEMENT OF ANY DAMAGED COMPONENTS, ESPECIALLY THOSE THAT MAY PREVENT THE PROPER SEALING OF THE FIXTURE (CONTACT HOLOPHANE FIELD SERVICE DEPARTMENT). FAILURE TO DO SO MAY RESULT IN SIGNIFICANT PROPERTY DAMAGE. 3.1.9 Wipe the gasket and seal area clean with a clean, dry rag and ensure that no dirt or debris will prevent an adequate seal during closing. 3.1.10 Close the door. Tighten the captive door screws to 55 in. lbs. torque. This is required for watertight door seal. 3.2 Door Replacement/Repair. 3.2.1 De-energize the floodlight. 3.2.2 Wipe off the exterior of floodlight to remove dirt or debris that could enter when the door is opened. 3.2.3 Loosen the captive door screws attaching the door to the 3.2.4 Detach the power disconnect. 3.2.5 Remove the cotter pin from the hinge pin. 3.2.6 Slide the door hinge pins from the housing. CAUTION KEEP ELECTRICAL COMPONENTS DRY. DO NOT USE ABRASIVE CLEANSERS ON THE GLASS OR REFLECTOR. LOSS OF OPTICAL PERFORMANCE AND SUBSEQUENT GLASS BREAKAGE COULD RESULT.

3.3 Electrical Component Replacement. Electrical components mounted on the door can be replaced as follows: Figure 4 3.3.1 Tag electrical leads for use when installing the new components. 3.3.2 Break electrical connections. 3.3.3 Remove the attaching hardware and retain for reuse. 3.3.4 Remove the electrical component. 3.3.5 If needed during installation, remove any electrical or heat insulating components from the removed electrical component. Install them onto the new component. 3.3.6 Place the new component into position. 3.3.7 Install the attaching hardware. Tighten securely. 3.3.8 Make electrical connections in accordance with wire tags and approved wiring practices. 3.4 Door Installation. 3.4.1 Slide the door hinge pins into the housing. 3.4.2 Insert the cotter pin 3.4.3 Insert the door disconnect plug into the disconnect receptacle 3.4.4 Check the condition of the door gasket and seal area on the housing. Ensure that no damage exists that could affect seal integrity. 3.4.5 Check the interior of the housing and door for evidence of damage or potentially hazardous conditions. FOR REPLACEMENT OF ANY DAMAGED COMPONENTS, ESPECIALLY THOSE THAT MAY PREVENT THE PROPER SEALING OF THE FIXTURE (CONTACT HOLOPHANE FIELD SERVICE DEPARTMENT). FAILURE TO DO SO MAY RESULT IN SIGNIFICANT PROPERTY DAMAGE. 3.4.6 Wipe the gasket and seal area clean with a clean, dry rag and ensure that no dirt or debris will prevent an adequate seal during closing. 3.4.7 Close the door. Tighten the captive door screws to 55 in. lbs. torque. This is required for watertight door seal. 3.4.8 Energize the floodlight. Check its operation and for proper area illumination. 4.2 Visor Installation and Maintenance. When installed, the visor limits the vertical spread of emitted light. 4.2.1 Attach the clips to the visor, one in the center and one on each corner at approximately the location of the holes. The visor goes into the narrow side of the clip. See Figure 5. 4.2.2 Fasten the visor with the clips to the door assembly. A small screwdriver can be used to spread the leg of clips to start them over the cast rib on the door. NOTE Three 3/16" diameter holes in visor can be used as a template if the installer chooses to drill holes through the casting rib and fasten the visor to the door with screws (not included). Screws are recommended in high wind and rough service areas. 4.2.3 Clean accumulated dust and dirt from visor when relamping. Figure 5 GR422 4. OPTIONS OR ACCESSORIES The following options or accessories may be present on your installation. 4.1 Shield Installation and Maintenance. When installed, these limit the horizontal spread of emitted light. 4.1.1 Remove the captive door screws from the side of the door. See Figure 4. 4.1.2 Align the mounting hole in the shields with holes in the door. Place the shield on the side of the door. 4.1.3 Insert the screw through the shield mounting holes and the door and thread into the housing. Tighten captive door screws to 55 in. lbs. torque. This is required for water tight door seal. 4.1.4 Clean accumulated dust and dirt from door before relamping. GR423

4.3 Wire Guard Installation and Maintenance. When installed, the wire guard helps protect the tempered glass lens from damage. 4.3.1 Loosen the captive door screws. See Figure 6. 4.3.2 Slide the mounting loops in the wire guard over all four screws. 4.3.3 Tighten captive door screws to 55 in. lbs. torque. This is required for watertight door seal. Figure 6 GR424 5. Limited Warranty and Limitation of Liability The Holophane limited warranty and limitation of liability is published in the "Terms and Conditions" section of the current Holophane buyer's guide, and is available from your local Holophane sales representative. Acuity Lighting Group, Inc. 214 Oakwood Ave., Newark, OH 43055 IM-62-E 8/06 2006 Acuity Lighting Group Inc. Visit our web site at www.holophane.com Printed in USA