CHAPTER 3 INTEGRITY WOOD ULTREX DOUBLE HUNG

Similar documents
Siteline EX Clad Casement Windows Premium Wood

General Information SECTION DIRECTORY

Pella Impervia 350 Series Vinyl Awning Windows and Sliding Patio Doors

Architect Series Traditional

Product Selection Guide Size and Performance Data...W-HG-2 Features and Options...W-HG-3 Combination Assemblies...W-HG-4 Glazing Performance...

SIZE AND PERFORMANCE SUMMARY GLAZING PERFORMANCE GRILLE PROFILES AND PATTERNS SIZE TABLES DESIGN DATA DETAILED PRODUCT DESCRIPTION CROSS SECTIONS

Casement Windows Builders Clad-Wood

Sliding Patio Doors Builders Vinyl

Pella 450 Series. Size and performance summary. Glazing performance. Grille profiles and patterns. Size tables. Design Data

Specifications... Quick Spec Guide...

Size and performance summary. Glazing performance. Grille profiles and patterns. Size tables. Design Data. Detailed Product Description

Size and performance summary. Glazing performance. Grille profiles and patterns. Size tables. Design Data. Detailed Product Description

Sliding Patio Doors Flat Casing Vinyl

CASEMENT. Operator / Stationary Units

SECTION DIRECTORY. Designer Series DS-AW-1 AWNING

Sliding Windows Brickmould Vinyl

French View Primed Hinged Patio Doors Premium Wood

Lifestyle Series Casement

SIZE AND PERFORMANCE SUMMARY GLAZING PERFORMANCE GRILLE PROFILES AND PATTERNS SIZE TABLES DESIGN DATA DETAILED PRODUCT DESCRIPTION CROSS SECTIONS

Single-Hung Tilt Windows Builders Vinyl

DOUBLE/SINGLE HUNG WINDOWS

Primed Epicr Radius and Geometric Windows - In-Sash Custom Wood

HURRICANESHIELD IMPACT-RESISTANT GLASS SECTION DIRECTORY. Size and performance summary. Glazing performance. Grille profiles and patterns.

Visions 2000 Double Hung Tilt Window Parts Reference Catalog

Gliding Windows Premium Vinyl

DF COLLECTION. Architectural Detail Guide Hybrid Awning Window DF 3113 TABLE OF CONTENTS

SIZE AND PERFORMANCE SUMMARY GLAZING PERFORMANCE GRILLE PROFILES AND PATTERNS SIZE TABLES DESIGN DATA DETAILED PRODUCT DESCRIPTION CROSS SECTIONS

Siteline Clad Swinging Patio Doors Premium Wood

Warranty, Parts & Install Info 1. Series 4600 Double Hung Windows 2. Series 4710 Casement Windows 3. Series 9000 Sliding Patio Door 4

Architect Series Traditional

Intelligent Design. Superior Performance.

Size and performance summary. Glazing performance. Grille profiles and patterns. Size tables. Design Data. Detailed Product Description

General Information. Product Details SECTION DIRECTORY

Size and performance summary. Glazing performance. Grille profiles and patterns. Size tables. Design Data. Detailed Product Description

Sliding Windows Builders Vinyl

Aluminum Wood Double-Hung Windows

SIZE AND PERFORMANCE SUMMARY GLAZING PERFORMANCE GRILLE PROFILES AND PATTERNS SIZE TABLES DESIGN DATA DETAILED PRODUCT DESCRIPTION CROSS SECTIONS

Technical Guide E. EDouble/Single Hung Windows. Technical Guide E1

SECTION DIRECTORY. Designer Series W-OSD-1 OUT-SWING DOOR

3948 Townsfair Way, Suite 200 July 2013 Columbus, Ohio Toll Free Website

Size and performance summary. Glazing performance. Grille profiles and patterns. Size tables. Design Data. Detailed Product Description

100 Series Single-Hung Windows (2008 to Present)

Single-Hung Windows Builders Aluminum

Siteline EX Primed Casement Windows Premium Wood

Single-Hung Side Load Windows Builders Vinyl

Product Guide Specification

Clad Traditional Sliding Patio Doors Premium Wood

Clad Radius and Geometric Windows - Direct-Set Custom Wood

Siteline EX Clad Double-Hung Windows Premium Wood

Technical Guide B Casement Windows. Casement Windows. Technical Guide B1

TEA2 Architects LAKE SUPERIOR RESIDENCE TECHNICAL GUIDE C AWNING WINDOWS

Single-Hung Windows Premium Atlantic Vinyl

Pella 250 Series. Size and performance summary. Glazing performance. Grille profiles and patterns. Size tables. Design Data

Smooth, clean lines for a higher quality look than ordinary vinyl. Exceptional energy efficiency with double- and triple-pane glass options

Primed Traditional Sliding Patio Doors Premium Wood

BUILDER SERIES MODULAR SIZING SUPPLEMENT BUILDER SERIES Single Hung & Double Hung

100 Series Single-Hung Windows (2008 to Present)

TABLE OF CONTENTS. These three boxes can be changed/resized; whatever works best with the amount of images available to you.

Architect Series Designer Series Pella ProLine. Architect Series...AW-1 Designer Series...AW-2 Pella ProLine...AW-2

Euroview Vinyl Tilt/Turn, Hopper & Picture Windows

Series 8010 Vinyl Double Hung Windows Visit MGMIndustries.com for a complete online catalog Page

The Falcon Series... Setting The Standard

100 Series Single-Hung Windows (2008 to Present)

Product Guide Specification

BELVEDERE PROJECT TECHNICAL GUIDE ACCESS WINDOWS

V3 Series Awning Windows (2011 to Present)

TEA2 Architects LAKE SUPERIOR RESIDENCE TECHNICAL GUIDE AWNING WINDOWS

Siteline EX Primed Double-Hung Windows Premium Wood

Guide Specification SECTION VINYL WINDOWS

Architectural Manual. Vinyl Windows & Patio Doors

Perma-Shield Gliding Patio Doors

100 Series Gliding Windows (2008 to Present)

BROSCO SSB Window Unit

EPICVUE CLAD-WOOD PATIO DOOR SLIDING PATIO DOOR TABLE OF CONTENTS

Technical Data: elevations

100 Series Awning Windows (2008 to Present)

Double Hung. Power Lift 28,000 Constant Force

your vision, our windows

NFRC U-FACTOR, SHGC / VT, CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: EARTHWISE GROUP, L.L.C.

Technical Guide C. CAwning Windows. Technical Guide C1

Durable, easy-care vinyl that will look great for years. Energy-efficient options that keep your home more comfortable

100 Series Gliding Windows (2008 to Present)

SIZE AND PERFORMANCE SUMMARY GLAZING PERFORMANCE GRILLE PROFILES AND PATTERNS SIZE TABLES DESIGN DATA DETAILED PRODUCT DESCRIPTION CROSS SECTIONS

WA67 Folding System - Aluminum Clad Over Wood

100 Series Awning Windows (2008 to Present)

LUXURY SLIDING PATIO & SWINGING FRENCH DOORS

Primed Casement Windows (1932 to 1989)

Aluminum Series SH600 Product Specifications

100 Series Awning Windows (2008 to Present)

Casement Windows Premium Atlantic Vinyl

Primed Casement Windows (1932 to 1989)

NFRC U-FACTOR, SHGC / VT, CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: EARTHWISE GROUP, L.L.C.

Note: PGT reserves the right to change material design and/or construction without notice or liability Window Height

100 Series Gliding Windows (2008 to Present)

StyleGuard. Impact-Resistant Windows and Doors Edition

Primed Out-Swing Patio Doors Custom Wood

400 Series Flexiframe Windows (1985 to Present)

ALUMINUM HORIZONTAL ROLLER WINDOW

Builders Know The Difference.

350/500 Tuffline TM Entrances 1

Transcription:

CHAPTER 3 INTEGRITY WOOD ULTREX DOUBLE HUNG Specifications / NFRC Values... 3.2 Egress, Lite and Vent Measurements... 3.3 Egress, Lite and Vent Measurements / Abbreviations... 3.4 Sizing Guidelines / Measurement Conversions... 3.6 Design Pressure... 3.7 Structural Comparative Analysis... 3.8 Elevations -- Double Hung Units... 3.9 Elevations -- Cottage, Transom / Picture... 3.11 Section Details -- Operating... 3.13 Section Details -- Transom / Picture... 3.14 Section Details -- Mullions... 3.15 30_ Bay Units... 3.16 30_ Bay Units... 3.17 45_ Bay Units... 3.18 45_ Bay Units... 3.19 Installation Suggestions... 3.20 D D D D D ATTENTION: Specifications and technical data are subject to change without notice. Allow 1/16 (1.59 mm) tolerance on all measurements. Interior mullion trim are shipped loose for field installation. For answers to technical questions about Integrity products you may call our Integrity Support Line: 1--800--587--2712. Website: www.integritywindows.com 3.1

SPECIFICATIONS AND NFRC VALUES FRAME: The frame is made of Ultrex, an advanced fiber reinforced material that is exceptionally resistant to thermal conductance. The interior is clear pine, kiln dried to a moisture content of 6-12% at time of fabrication. Water -repellent, preservative treated in accordance with WDMA I.S.4. Composite frame thickness is 1 9/16 (40 mm). width of 4 9/16 (116 mm). Clear pine interior frame liner is applied to all units. Ultrex is.075 (2mm) thick. Color: Stone white and pebble gray. SASH: The sash is made of Ultrex, an advanced fiber reinforced material that is exceptionally resistant to thermal conductance. The interior is clear pine, kiln dried to a moisture content of 6-12% at time of fabrication. Water -repellent, preservative treated in accordance with WDMA I.S.4. Composite thickness of 1 17/32 (39 mm). Ultrex is.070 -.075 (2mm) thick. Color: Stone white and pebble gray. EXTENSION: 49/16 (116 mm) is standard. Optional 6 9/16 (167 mm) and 6 13/16 (173 mm) jamb extension factory applied or in lineal lengths for field application. HARDWARE: The balance system is a coil spring block and tackle system, with nylon cord and steel locking shoe. Both sash tilt into the room for cleaning or removal for painting without removing the screen. High pressure zinc die cast checkrail lock and keeper. Lock employs a cam -lock mechanism. Color: Almond frost or White. Each sash employs spring loaded tilt latches to allow for easy tilting of sash. INSTALLATION: Factory applied folding nailing fin and drip cap system. Optional installation brackets for masonry available. Factory supplied field mulling kits are available for standard assemblies or 30 and 45 Bay assemblies. GLAZING: All units manufactured with 3/4 (19 mm) insulating glass Low E II with Argon [Tempered Obscure Low E II with Argon - call numbers 2236, 2636, 3036, 2240, 2640, and 3040]. All glass is of a select quality complying with Federal Specifications DD-F-451D, ASTM C 1036-85. Insulating glass is manufactured and tested to pass level CBA, ASTM E 774-92 and is IGCC certified. The glazing seal is a silicone bedding on both interior and exterior surfaces. WEATHER -STRIPPING: All units have full perimeter frame weather -strip. The sash is sealed to the jambs using a flexible gasket. The sill is sealed to the sash using a flexible bulb gasket. The head jamb is sealed to the sash using a leaf weather -strip. The checkrails are sealed using a flexible bulb gasket. SCREEN: Charcoal color fiberglass (non -corrosive) screen cloth, 18 x 16 mesh, set in a stone white or pebble gray color aluminum frame to match the exterior Ultrex. GRILLES: Wood removable and aluminum grilles between the glass panes are available in standard rectangular patterns. Wood grilles are manufactured from clear pine with a 3/4 (19 mm) x 15/32 (12 mm) bar. Grilles -Between -the -Glass (GBGs) are manufactured from aluminum in an 11/16 (17 mm) wide contoured profile placed between the two panes of glass. Colors: white (white interior and exterior) and pebble (white interior and pebble exterior). INTERIOR FINISH: Ultrex exposed to the interior is standard pearl white. Available in treated bare wood or factory applied white finish. PERFORMANCE RATING: Complies win ANSI / AAMA / WDMA 101 / I.S. 2, and NASF -02. THERMAL PERFORMANCE: CERTIFIED NFRC UNIT VALUES U-VALUES R-VALUES VLT SHGC Energy Star PRODUCT GLAZING* 42x60 42x60 42 x 60 42x60 Integrity Wood Ultrex Double Hung Low E II Argon.30 3.33.54.32 N, NC, SC, S Integrity Wood Ultrex Double Hung Low E II GBG Argon.30 3.33.48.28 N, NC, SC, S Integrity Wood Ultrex Double Hung Transom/Picture Low E II Argon.28 3.57.57.33 N, NC, SC, S Integrity Wood Ultrex Double Hung Transom/Picture Low E II GBG Argon.29 3.45.51.30 N, NC, SC, S Integrity Wood Ultrex Double Hung Picture Low E II Argon (4mm Glass).29 3.45.57.33 N, NC, SC, S Integrity Wood Ultrex Double Hung Picture Low E II GBG Argon (4mm Glass).30 3.33.51.30 N, NC, SC, S Product Values are determined using the National Fenestration Rating Council Procedure for determining fenestration product thermal values. U -Value - (Btu/hr -sq ft -_F) Lower the U -Value, the greater the resistance to heat flow and better its insulating value. R -Value - (1/U -Value) Higher the R -Value, the greater the resistance to heat flow and better its insulating value. VLT - Visible Light Transmittance - Percentage of visible light transmitted through the unit. SHGC - Solar Heat Gain Coefficient - The lower a window s SHGC, the less solar heat it transmits, and the greater its shading ability. *Note: Capillary tubes are required for IG units at high elevations. Argon will not be furnished in units with capillary tubes. Contact the Architectural Department (1-800 -346-3363) for NFRC Unit Values glazed Low E II with Air. 3.2

EGRESS, LITE, AND VENT MEASUREMENTS GRILLE PATTERN GRILLE LITE SIZE EGRESS, LITE, AND VENT MEASUREMENTS LITE Sq.ft VENT Sq. ft EGRESS WIDTH EGRESS HEIGHT EGRESS Sq. ft FLOOR TO BOTTOM OF CLEAR OPENING UNIT # ITDH 2236 2W2H 7.47 X 6.47 2.98 1.70 18.37 13.34 1.70 48.59 2240 2W2H 7.47 X 7.47 3.42 1.96 18.37 15.34 1.96 44.59 2248 2W2H 7.47 X 9.47 4.29 2.47 18.37 19.34 2.47 36.59 2252 2W2H 7.47 X 10.47 4.73 2.72 18.37 21.34 2.72 32.59 2256 2W2H 7.47 X 11.47 5.16 2.98 18.37 23.34 2.98 28.59 2260 2W2H 7.47 X 12.47 5.60 3.23 18.37 25.34 3.23 24.59 2264 2W2H 7.47 X 13.47 6.03 3.49 18.37 27.34 3.49 20.59 2272 2W3H 7.47 X 10.06 6.90 4.00 18.37 31.34 4.00 12.59 2276 2W3H 7.47 X 10.59 7.34 4.25 18.37 33.34 4.25 8.59 2636 3W2H 6.06 X 6.47 3.74 2.07 22.37 13.34 2.07 48.59 2640 3W2H 6.06 X 7.47 4.29 2.38 22.37 15.34 2.38 44.59 2648 3W2H 6.06 X 9.47 5.38 3.01 22.37 19.34 3.01 36.59 2652 3W2H 6.06 X 10.47 5.93 3.32 22.37 21.34 3.32 32.59 2656 3W2H 6.06 X 11.47 6.48 3.63 22.37 23.34 3.63 28.59 2660 3W2H 6.06 X 12.47 7.02 3.94 22.37 25.34 3.94 24.59 2664 3W2H 6.06 X 13.47 7.57 4.25 22.37 27.34 4.25 20.59 2672 3W3H 6.06 X 10.06 8.66 4.87 22.37 31.34 4.87 12.59 2676 3W3H 6.06 X 10.59 9.21 5.18 22.37 33.34 5.18 8.59 3036 3W2H 7.40 X 6.47 4.50 2.44 26.37 13.34 2.44 48.59 3040 3W2H 7.40 X 7.47 5.16 2.81 26.37 15.34 2.81 44.59 3048 3W2H 7.40 X 9.47 6.48 3.54 26.37 19.34 3.54 36.59 3052 3W2H 7.40 X 10.47 7.14 3.91 26.37 21.34 3.91 32.59 3056 3W2H 7.40 X 11.47 7.79 4.28 26.37 23.34 4.28 28.59 3060 3W2H 7.40 X 12.47 8.45 4.64 26.37 25.34 4.64 24.59 3064 3W2H 7.40 X 13.47 9.11 5.01 26.37 27.34 5.01 20.59 *3072 3W3H 7.40 X 10.06 10.43 5.74 26.37 31.34 5.74 12.59 *3076 3W3H 7.40 X 10.59 11.08 6.11 26.37 33.34 6.11 8.59 3436 3W2H 8.73 X 6.47 5.26 2.81 30.37 13.34 2.81 48.59 3440 3W2H 8.73 X 7.47 6.03 3.24 30.37 15.34 3.24 44.59 3448 3W2H 8.73 X 9.47 7.57 4.08 30.37 19.34 4.08 36.59 3452 3W2H 8.73 X 10.47 8.34 4.50 30.37 21.34 4.50 32.59 3456 3W2H 8.73 X 11.47 9.11 4.92 30.37 23.34 4.92 28.59 3460 3W2H 8.73 X 12.47 9.88 5.35 30.37 25.34 5.35 24.59 *3464 3W2H 8.73 X 13.47 10.65 5.77 30.37 27.34 5.77 20.59 *3472 3W3H 8.73 X 10.06 12.19 6.61 30.37 31.34 6.61 12.59 *3476 3W3H 8.73 X 10.59 12.95 7.03 30.37 33.34 7.03 8.59 3636 3W2H 9.40 X 6.47 5.64 3.00 32.37 13.34 3.00 48.59 3640 3W2H 9.40 X 7.47 6.47 3.45 32.37 15.34 3.45 44.59 3648 3W2H 9.40 X 9.47 8.12 4.35 32.37 19.34 4.35 36.59 3652 3W2H 9.40 X 10.47 8.94 4.80 32.37 21.34 4.80 32.59 3656 3W2H 9.40 X 11.47 9.77 5.40 32.37 24.04 5.40 28.59 *3660 3W2H 9.40 X 12.47 10.59 5.70 32.37 25.34 5.70 24.59 *3664 3W2H 9.40 X 13.47 11.42 6.15 32.37 27.34 6.15 20.59 *3672 3W3H 9.40 X 10.06 13.07 7.05 32.37 31.34 7.05 12.59 *3676 3W3H 9.40 X 10.59 13.89 7.50 32.37 33.34 7.50 8.59 3836 4W2H 7.36 X 6.47 6.02 3.18 34.37 13.34 3.18 48.59 3840 4W2H 7.36 X 7.47 6.90 3.66 34.37 15.34 3.66 44.59 3848 4W2H 7.36 X 9.47 8.66 4.62 34.37 19.34 4.62 36.59 3852 4W2H 7.36 X 10.47 9.55 5.09 34.37 21.34 5.09 32.59 *3856 4W2H 7.36 X 11.47 10.43 5.74 34.37 24.04 5.74 28.59 *3860 4W2H 7.36 X 12.47 11.31 6.05 34.37 25.34 6.05 24.59 *3864 4W2H 7.36 X 13.47 12.19 6.53 34.37 27.34 6.53 20.59 *3872 4W3H 7.36 X 10.06 13.95 7.48 34.37 31.34 7.48 12.59 *3876 4W3H 7.36 X 10.59 14.83 7.96 34.37 33.34 7.96 8.59 4236 4W2H 8.36 X 6.47 6.78 3.56 38.37 13.34 3.56 48.59 4240 4W2H 8.36 X 7.47 7.78 4.09 38.37 15.34 4.09 44.59 4248 4W2H 8.36 X 9.47 9.76 5.15 38.37 19.34 5.15 36.59 4252 4W2H 8.36 X 10.47 10.75 5.69 38.37 21.34 5.69 32.59 *4256 4W2H 8.36 X 11.47 11.74 6.40 38.37 24.04 6.40 28.59 *4260 4W2H 8.36 X 12.47 12.73 6.75 38.37 25.34 6.75 24.59 *4264 4W2H 8.36 X 13.47 13.72 7.29 38.37 27.34 7.29 20.59 *4272 4W3H 8.36 X 10.06 15.71 8.35 38.37 31.34 8.35 12.59 *4276 4W3H 8.36 X 10.59 16.70 8.88 38.37 33.34 8.88 8.59 See Notes on page 3.4. * These units meet egress. 3.3

EGRESS. LITE, AND VENT MEASUREMENTS GRILLE PATTERN EGRESS, LITE, AND VENT MEASUREMENTS GRILLE LITE SIZE LITE Sq. ft VENT Sq. ft EGRESS WIDTH EGRESS HEIGHT EGRESS Sq. ft FLOOR TO BOTTOM OF CLEAR OPENING UNIT # COTTAGE ITDH TOP 2268 C 2W2H 7.47 X 11.47 BOTTOM 2W3H 7.47 X 11.40 6.47 3.07 18.37 24.04 3.07 16.59 2668 C 3W2H 6.06 X 11.47 BOTTOM 3W3H 6.06 X 11.40 8.12 3.73 22.37 24.04 3.73 16.59 3068 C 3W2H 7.40 X 11.47 BOTTOM 3W3H 7.40 X 11.40 9.77 4.40 26.37 24.04 4.40 16.59 3468 C 3W2H 8.73 X 11.47 BOTTOM 3W3H 8.73 X 11.40 11.42 5.07 30.37 24.04 5.07 16.59 3668 C 3W2H 9.40 X 11.47 BOTTOM 3W3H 9.40 X 11.40 12.24 5.40 32.37 24.04 5.40 16.59 3868 C 4W2H 7.36 X 11.47 *BOTTOM 4W3H 7.36 X 11.40 13.07 5.74 34.37 24.04 5.74 16.59 4268 C 4W2H 8.26 X 11.47 *BOTTOM 4W3H 8.26 X 11.40 14.72 6.40 38.37 24.04 6.40 16.59 * These units meet Egress ABBREVIATIONS C=Cottage Style FS = GBG = Grille between glass ITDH = Integrity Wood Ultrex Double Hung ITDHP = Integrity Wood Ultrex Double Hung Picture ITDHTR = Integrity Wood Ultrex Double Hung Transom MO = Masonry Mas Opg = Masonry mm = Millimeters N/A = Not Available OM = Outside Measurement Rgh. Opg = RO = Sq. ft = Square Feet 2W = 2 Units Wide 3W = 3 Units Wide International Building Code - 2000 Section 1009 Emergency Escape and Rescue 1009.2 Minimum size: Emergency escape and rescue openings shall have a minimum net clear opening of 5.7 square feet (0.53m 2 ). Exception: The minimum net clear opening for emergency escape and rescue openings on the ground level at grade is 5.0 square feet (0.46m 2 ). 1009.2.1 Minimum dimensions: The minimum net clear opening height dimension shall be 24 inches (610 mm). The net clear opening width dimension shall be 20 inches (508 mm). The net clear opening dimensions shall be the result of normal operation of the opening. 1009.3 Maximum height from the floor: Emergency escape and rescue opening shall have the bottom of the clear opening not greater than 44 inches (1118 mm) measured from the floor. 1009.4 Operational constraints: Emergency escape and rescue openings shall be operational from the inside of the room without the use of keys or tools. Bars, grilles, grates, or similar devices are permitted to be placed over emergency escape and rescue openings provided the minimum net clear opening size complies with Section 1009.2 and such devices shall be releasable or removable from the inside without the use of a key, tool, or force greater than that which is required for normal operation of the escape and rescue opening. Code restrictions may vary depending on your local building codes. EGRESS MEASUREMENTS Net Clear Height Net Clear Width Double Hung Unit Not to Scale Clear height at bottom sash rail to sill. 3.4

EGRESS. LITE, AND VENT MEASUREMENTS EGRESS, LITE, AND VENT MEASUREMENTS UNIT # GRILLE PATTERN GRILLE LITE SIZE LITE Sq. ft TRANSOM ITDHTR 2216 2W1H 7.47 X 9.59 1.06 2616 3W1H 6.06 X 9.59 1.32 3016 3W1H 7.40 X 9.59 1.59 3416 3W1H 8.73 X 9.59 1.86 3616 3W1H 9.40 X 9.59 2.00 3816 4W1H 7.36 X 9.59 2.13 4216 4W1H 8.36 X 9.59 2.40 PICTURE ITDHP 3840 4W4H 9.81 X 7.26 7.41 3848 4W4H 9.81 X 9.26 9.17 3852 4W4H 9.81 X 10.26 10.05 3856 4W4H 9.81 X 11.26 10.93 3860 4W4H 9.81 X 12.26 11.81 3864 4W4H 9.81 X 13.26 12.69 3872 4W6H 9.81 X 9.93 14.46 3876 4W6H 9.81 X 10.59 15.34 4240 4W4H 8.36 X 7.26 8.35 4248 4W4H 8.36 X 9.26 10.33 4252 4W4H 8.36 X 10.26 11.32 4256 4W4H 8.36 X 11.26 12.31 4260 4W4H 8.36 X 12.26 13.30 4264 4W4H 8.36 X 13.26 14.30 4272 4W6H 8.36 X 9.93 16.28 4276 4W6H 8.36 X 10.59 17.27 5040 5W4H 8.14 X 7.26 10.22 5048 5W4H 8.14 X 9.26 12.65 5052 5W4H 8.14 X 10.26 13.86 5056 5W4H 8.14 X 11.26 15.07 5060 5W4H 8.14 X 12.26 16.29 5064 5W4H 8.14 X 13.26 17.50 5072 5W6H 8.14 X 9.93 19.93 5076 5W6H 8.14 X 10.59 21.14 5440 5W4H 8.94 X 7.26 11.16 5448 5W4H 8.94 X 9.26 13.81 5452 5W4H 8.94 X 10.26 15.13 5456 5W4H 8.94 X 11.26 16.45 5460 5W4H 8.94 X 12.26 17.78 5464 5W4H 8.94 X 13.26 19.10 5468 5W5H 8.94 X 11.26 20.42 5472 5W6H 8.94 X 9.93 21.75 5476 5W6H 8.94 X 10.59 23.08 6240 6W4H 8.65 X 7.26 13.03 6248 6W4H 8.65 X 9.26 16.12 6252 6W4H 8.65 X 10.26 17.67 6256 6W4H 8.65 X 11.26 19.21 6260 6W4H 8.65 X 12.26 20.76 6264 6W4H 8.65 X 13.26 22.31 NOTE: Picture Lite cut measurements are for the first lite cut only. This to ensure bar alightment on mulled units. 3.5

SIZING GUIDELINES AND MEASUREMENT CONVERSIONS MULTIPLE ASSEMBLIES Units may be factory mulled up to 4 units wide by 1 unit high OR 2 unit wide by 2 units high. Field mull kits are available. Mulling beyond limitations is not recommended. MAXIMUM ASSEMBLY UP TO 4W1H: 113 1/2 (2883 mm) X 76 1/4 (1937mm) MAXIMUM ASSEMBLY UP TO 2W2H :84 (2134 mm) X 92 (2337mm) NOTE: 6 9/16 (167 mm) and 6 13/16 (173) jamb extension available factory applied or in lineal lengths for field application. CALCULATING TOTAL ROUGH OPENING FOR ASSEMBLIES WIDTH: ADD Widths + 1 (25 mm) Tolerance = 1/2 (13 mm) from frame to at left and right jamb. HEIGHT: ADD Heights + 1/2 (13 mm) Tolerance = 1/2 (13 mm) from to at head jamb. 3UnitsWide1UnitHigh 2UnitsWide1UnitHigh 1UnitWide 2 Units High MEASUREMENT CONVERSIONS Wood Ultrex Double Hung WIDTH HEIGHT to Imperial Metric Imperial Metric Masonry - 1/2I - 13 mm - 1/4I - 6 mm OM of - 1I - 25 mm - 1/2I - 13 mm OM Sash - 3 9/16I - 90 mm ( 2) - 1 3/16I ( 2) - 30 mm Daylight - 6 13/16I - 173 mm ( 2) - 4 7/16I ( 2) - 113 mm Om of Glass - 5 3/4I - 146 mm ( 2) - 3 3/8I ( 2) - 86 mm OM of Screen - 3I - 76 mm - 2 1/4I - 57 mm PICTURE / TRANSOM Masonry - 1/2I - 13 mm - 1/4I - 6 mm OM of - 1I - 25 mm - 1/2I - 13 mm OM Sash - 3 9/16I - 90 mm 35/16I - 84 mm Daylight - 6 13/16I - 173 mm - 6 9/16I - 167 mm Om of Glass - 5 3/4I - 146 mm - 5 1/2I - 140 mm 1/06 3.6

DESIGN PRESSURE Nominal Height INTEGRITY Standard s and WDMA Ratings of Standard Operable Units Nominal Width Width, inches Height, inches 22 21.50 26 25.50 30 29.50 34 33.50 36 35.50 38 37.50 42 41.50 36 35.75 LC +40/--50 LC +40/--50 LC +40/--50 LC +40/--50 LC +40/--50 LC +40/--50 LC +40/--50 40 39.75 LC +40/--50 LC +40/--50 LC +40/--50 LC +40/--50 LC +40/--50 LC +40/--50 LC +40/--50 48 47.75 LC +40/--50 LC +40/--50 LC +40/--50 LC +40/--50 LC +40/--50 LC +40/--50 LC +40/--50 52 51.75 LC +40/--50 LC +40/--50 LC +40/--50 LC +40/--50 LC +40/--50 LC +40/--50 LC +40/--50 56 55.75 LC +40/--50 LC +40/--50 LC +40/--50 LC +40/--50 LC +40/--50 LC +40/--50 LC +40/--50 60 59.75 LC +40/--50 LC +40/--50 LC +40/--50 LC +40/--50 LC +40/--50 LC +40/--50 LC +40/--50 64 63.75 LC +40/--50 LC +40/--50 LC +40/--50 LC +40/--50 LC +40/--50 LC +40/--50 LC +40/--50 C68 67.75 LC +40/--50 LC +40/--50 LC +40/--50 LC +40/--50 LC +40/--50 LC +40/--50 LC +40/--50 72 71.75 LC +40/--50 LC +40/--50 LC +40/--50 LC +40/--50 LC +40/--50 LC +40/--50 LC +40/--50 76 75.75 LC +40/--50 LC +40/--50 LC +40/--50 LC +40/--50 LC +40/--50 LC +40/--50 LC +40/--50 Nominal Height INTEGRITY WOOD ULTREX TRANSOM Standard s and WDMA Ratings of Standard Operable Units Nominal Width Width, inches Height, inches 22 21.50 26 25.50 30 29.50 34 33.50 36 35.50 38 37.50 42 41.50 16 15375 LC +40/--50 LC +40/--50 LC +40/--50 LC +40/--50 LC +40/--50 LC +40/--50 LC +40/--50 INTEGRITY WOOD ULTREX PICTURE Standard s and WDMA Ratings of Standard Operable Units Nominal Width Width, inches Nominal Height Height, inches 38 37.50 42 41.50 50 49.50 54 53.50 62 61.50 40 39.75 LC +40/--50 LC +40/--50 LC +40/--50 LC +40/--50 LC +40/--50 48 47.75 LC +40/--50 LC +40/--50 LC +40/--50 LC +40/--500 LC +40/--50 52 51.75 LC +40/--50 LC +40/--50 LC +40/--50 LC +40/--50 LC +40/--50 56 55.75 LC +40/--50 LC +40/--50 LC +40/--50 LC +40/--50 LC +40/--50 60 59.75 LC +40/--500 LC +40/--50 LC +40/--50 LC +40/--50 LC +40/--50 64 63.75 LC +40/--50 LC +40/--50 LC +40/--50 LC +40/--50 LC +40/--50 C68 67.75 LC +40/--50 72 71.75 LC +40/--50 LC +40/--50 LC +40/--50 LC +40/--50 76 75.75 LC +40/--50 LC +40/--50 LC +40/--50 LC +40/--50 3/06 3.7

STRUCTURAL ANALYSIS INTEGRITY STRUCTURAL COMPARATIVE ANALYSIS STRUCTURAL COMPARATIVE ANALYSIS - WITH HIGH PERFORMANCE KIT OPERATOR UNITS Positive/Negative PICTURE UNITS Positive/Negative Height/Width 22 26 30 34 36 38 42 Height/Width 38 42 50 54 62 36 50 / --75 50 / --75 50 / --75 50 / --75 50 / --75 50 / --73 50 / --69 40 50 / --75 50 / --75 50 / --70 50 / --66 50 / --57 40 50 / --75 50 / --75 50 / --75 50 / --73 50 / --71 50 / --69 50 / --66 48 50 / --74 50 / --70 50 / --64 50 / --55 50 / --58 48 50 / --75 50 / --75 50 / --73 50 / --68 50 / --65 50 / --63 50 / --60 52 50 / --71 50 / --67 50 / --54 50 / --50 50 / --55 52 50 / --75 50 / --75 50 / --71 50 / --65 50 / --63 50 / --61 50 / --57 56 50 / --69 50 / --65 50 / --51 47 / --57 50 / --53 56 50 / --75 50 / --75 50 / --69 50 / --64 50 / --61 50 / --59 50 / --55 60 50 / --67 50 / --56 47 / --57 44 / --55 50 / --51 60 50 / --75 50 / --75 50 / --67 50 / --62 50 / --60 50 / --58 50 / --53 64 50 / --56 50 / --53 45 / --56 41 / --53 50 / --50 64 50 / --75 50 / --73 50 / --66 50 / --61 50 / --58 50 / --56 50 / --52 68 50 / --52 68 50 / --75 50 / --75 50 / --66 50 / --58 50 / --55 50 / --52 50 / --47 72 50 / --61 50 / --59 50 / --53 50 / --50 72 50 / --75 50 / --71 50 / --64 50 / --58 50 / --56 50 / --54 50 / --50 76 50 / --56 50 / --56 50 / --52 50 / --50 76 50 / --75 50 / --70 50 / --63 50 / --57 50 / --55 50 / --53 50 / --50 TRANSOM UNITS Positive/Negative AAMA/NWWDA 101/I.S.2--97 and NAFS--1 Integrity Double Hung, Integrity Double Hung Picture Water Performance levels: IDH 4477: DP50, IDHP 6268: DP50 Height/Width 22 26 30 34 36 38 42 16 50 / --75 50 / --75 50 / --75 50 / --75 50 / --75 50 / --75 50 / --75 This HP kit is intended to enhance the performance of single units to the levels stated above. It is the responsibility of the installer of this HP kit to follow all instructions regarding structural enhancements for full structural performance and to comply with local codes regarding water and structural performance. All Integrity Double Hung operating units that meet National Egress Codes for fire evacuation will continue to meet these codes with the exclusion of the Integrity Double Hung High Performance Sill Kit. Local codes may differ. Egress Height will decrease and Floor To Clear Height will increase.433 inches (11mm). 1/06 3.8

ELEVATIONS -- UNITS Not To Scale Mas. Opg. 1-10 (559) Rgh. Opg. 1-10 1/2 (572) 1-9 1/2 (546) Glass 16 3/4 (425) 2-2 (660) 2-6 (762) 2-2 1/2 (673) 2-6 1/2 (775) 2-1 1/2 (648) 2-5 1/2 (749) 20 3/4 (527) 24 3/4 (629) 2-10 (864) 2-10 1/2 (876) 2-9 1/2 (851) 28 3/4 (730) 3-0 (914) 3-0 1/2 (927) 2-11 1/2 (902) 30 3/4 (781) 3-2 (965) 3-2 1/2 (978) 3-1 1/2 (953) 32 3/4 (832) 3-6 (1067) 3-6 1/2 (1080) 3-5 1/2 (1054) 36 3/4 (933) 3-0 (914) 3-0 1/4 (921) 2-11 3/4 (908) 14 3/4 (375) ITDH2236 ITDH2636 ITDH3036 ITDH3436 ITDH3636 ITDH3836 ITDH4236 3-4 (1016) 3-4 1/4 (1022) 3-3 3/4 (1010) 16 3/4 (425) ITDH2240 ITDH2640 ITDH3040 ITDH3440 ITDH3640 ITDH3840 ITDH4240 ITDH2248 ITDH2648 ITDH3048 ITDH3448 ITDH3648 ITDH3848 ITDH4248 ITDH2252 ITDH2652 ITDH3052 ITDH3452 ITDH3652 ITDH3852 ITDH4252 Mas. Opg. Rgh. Opg. Glass 4-8 (1422) 4-8 1/4 (1429) 4-7 3/4 (1416) 24 3/4 (629) 4-4 (1321) 4-4 1/4 (1327) 4-3 3/4 (1314) 22 3/4 (578) 4-0 (1219) 4-0 1/4 (1226) 3-11 3/4 (1213) 20 3/4 (527) ITDH2256 ITDH2656 ITDH3056 ITDH3456 ITDH3656 ITDH3856* ITDH4256* NOTE: When ordering 69/16I jambs, add 1/4I to width and 1/8I to height for, and Masonry * These windows meet National Egress Codes for fire evacuation. Local codes may differ. Standard grille patterns shown in above units. Units are available with or without grilles. Imperial and metric dimensions are shown. Metric dimensions are in millimeters. All units viewed from exterior. 3.9

ELEVATIONS -- UNITS Not To Scale Mas. Opg. 1-10 (559) Rgh. Opg. 1-10 1/2 (572) 1-9 1/2 (546) Glass 16 3/4 (425) 2-2 (660) 2-6 (762) 2-2 1/2 (673) 2-6 1/2 (775) 2-1 1/2 (648) 2-5 1/2 (749) 20 3/4 (527) 24 3/4 (629) 2-10 (864) 2-10 1/2 (876) 2-9 1/2 (851) 28 3/4 (730) 3-0 (914) 3-0 1/2 (927) 2-11 1/2 (902) 30 3/4 (781) 3-2 (965) 3-2 1/2 (978) 3-1 1/2 (953) 32 3/4 (832) 3-6 (1067) 3-6 1/2 (1080) 3-5 1/2 (1054) 36 3/4 (933) 5-0 (1524) 5-0 1/4 (1530) 4-11 3/4 (1518) 26 3/4 (679) ITDH2260 ITDH2660 ITDH3060 ITDH3460 ITDH3660* ITDH3860* ITDH4260* 5-4 (1626) 5-4 1/4 (1632) 5-3 3/4 (1619) 28 3/4 (730) ITDH2264 ITDH2664 ITDH3064 ITDH3464* ITDH3664* ITDH3864* ITDH4264* 6-0 (1829) 6-0 1/4 (1835) 5-11 3/4 (1822) 32 3/4 (832) ITDH2272 ITDH2672 ITDH3072* ITDH3472* ITDH3672* ITDH3872* ITDH4272* 6-4 (1930) 6-4 1/4 (1937) 6-3 3/4 (1924) 34 3/4 (883) Mas. Opg. Rgh. Opg. Glass ITDH2276 ITDH2676 ITDH3076* ITDH3476* ITDH3676* ITDH3876* ITDH4276* NOTE: When ordering 69/16I jambs, add 1/4I to width and 1/8I to height for, and Masonry * These windows meet National Egress Codes for fire evacuation. Local codes may differ. Standard grille patterns shown in above units. Units are available with or without grilles. Imperial and metric dimensions are shown. Metric dimensions are in millimeters. All units viewed from exterior. 1/06 3.10

ELEVATIONS -- COTTAGE, TRANSOM, & PICTURE UNITS Not To Scale Mas. Opg. Rgh. Opg. Glass COTTAGE STYLE DOUBLE HUNG 1-10 (559) 2-2 (660) 1-10 1/2 (572) 2-2 1/2 (673) 1-9 1/2 (546) 2-1 1/2 (648) 16 3/4 (425) 20 3/4 (527) 2-6 (762) 2-6 1/2 (775) 2-5 1/2 (749) 24 3/4 (629) 2-10 (864) 2-10 1/2 (876) 2-9 1/2 (851) 28 3/4 (730) 3-0 (914) 3-0 1/2 (927) 2-11 1/2 (902) 30 3/4 (781) 3-2 (965) 3-2 1/2 (978) 3-1 1/2 (953) 32 3/4 (832) 3-6 (1067) 3-6 1/2 (1080) 3-5 1/2 (1054) 36 3/4 (933) 5-8 (1727) 5-8 1/4 (1734) 5-7 3/4 (1721) 36 3/4 (933) 24 3/4 (629) Mas. Opg. Rgh. Opg. Glass ITDH2268C ITDH268C ITDH3068C ITDH3468C ITDH3668C ITDH3868C* ITDH4268C* DOUBLE HUNG TRANSOM 1-10 (559) 1-10 1/2 (572) 1-9 1/2 (546) 16 3/4 (425) 2-2 (660) 2-2 1/2 (673) 2-1 1/2 (648) 20 3/4 (527) 2-6 (762) 2-6 1/2 (775) 2-5 1/2 (749) 24 3/4 (629) 2-10 (864) 2-10 1/2 (876) 2-9 1/2 (851) 28 3/4 (730) 3-0 (914) 3-0 1/2 (927) 2-11 1/2 (902) 30 3/4 (781) 3-2 (965) 3-2 1/2 (978) 3-1 1/2 (953) 32 3/4 (832) 3-6 (1067) 3-6 1/2 (1080) 3-5 1/2 (1054) 36 3/4 (933) 1-4 (406) 1-4 1/4 (413) 1-1 3/4 (400) 10 3/4 (273) ITDHTR2216 ITDHTR2616 ITDHTR3016 ITDHTR3416 ITDHTR3616 ITDHTR3816 ITDHTR4216 Mas. Opg. Rgh. Opg. Glass NOTE: * These windows meet National Egress Codes for fire evacuation. Local codes may differ. 3.11

ELEVATIONS -- COTTAGE, TRANSOM, & PICTURE UNITS Not To Scale DOUBLE HUNG PICTURE Mas. Opg. Rgh. Opg. Glass 3-2 (965) 3-2 1/2 (978) 3-1 1/2 (953) 32 3/4 (832) 3-6 (1067) 3-6 1/2 (1080) 3-5 1/2 (1054) 36 3/4 (933) 4-2 (1270) 4-2 1/2 (1283) 4-1 1/2 (1257) 44 3/4 (1137) 4-6 (1372) 4-6 1/2 (1384) 4-5 1/2 (1359) 48 3/4 (1238) 5-2 (1575) 5-2 1/2 (1588) 5-1 1/2 (1562) 56 3/4 (1441) 3-4 (1016) 3-4 1/4 (1022) 3-3 3/4 (1010) 34 3/4 (883) 4-0 (1219) 4-0 1/4 (1226) 3-11 3/4 (1213) 42 3/4 (1086) 4-4 (1321) 4-4 1/4 (1327) 4-3 3/4 (1314) 46 3/4 (1187) ITDHP3840 ITDHP4240 ITDHP5040 ITDHP5440 ITDHP6240 ITDHP3848 ITDHP4248 ITDHP5048 ITDHP5448 ITDHP6248 ITDHP3852 ITDHP4252 ITDHP5052 ITDHP5452 ITDHP6252 4-8 (1422) 4-8 1/4 (1429) 4-7 3/4 (1416) 50 3/4 (1289) ITDHP3856 ITDHP4256 ITDHP5056 ITDHP5456 ITDHP6256 5-0 (1524) 5-0 1/4 (1530) 4-11 3/4 (1518) 54 3/4 (1391) ITDHP3860 ITDHP460 ITDHP5060 ITDHP5460 ITDHP6260 5-4 (1626) 5-4 1/4 (1632) 5-3 3/4 (1619) 58 3/4 (1492) ITDHP3864 ITDHP464 ITDHP5064 ITDHP5464 ITDHP6264 5-8 (1727) 5-8 1/4 (1734) 5-7 3/4 (1721) 62 3/4 (1594) ITDHP5468 6-4 (1930) 6-4 1/4 (1937) 6-3 3/4 (1924) 70 3/4 (1797) 6-0 (1829) 6-0 1/4 (1835) 5-11 3/4 (1822) 66 3/4 (1695) ITDHP3872 ITDHP472 ITDHP5072 ITDHP5472 Mas. Opg. Rgh. Opg. Glass ITDHP3876 ITDHP476 ITDHP5076 ITDHP5476 1/06 3.12

SECTION DETAILS SCALE: 3I =1i0I OPERATING - 4 9/16 55/8 (144) 49/16 (116) OPERATING - 6 9/16 75/8 (194) 69/16 (167) HEAD (75) 13/32 (28) (74) 13/16 (30) Daylight CHECK RAIL 25/16 (59) Daylight Daylight 25/16 (59) Daylight 31/8 (80) 31/8 (79) SILL 13/8 (35) 13/8 (35) 49/16 S 13/32 (28) 69/16 S 13/16 (30) 49/16 (116) 5 21/32 (144) 69/16 (167) 75/8 (194) (74) Daylight (74) (74) Daylight (74) 1/06 3.13

SECTION DETAILS SCALE: 3I =1i0I TRANSOM / PICTURE - 4 9/16 55/8 (144) 49/16 (116) TRANSOM / PICTURE - 6 9/16 75/8 (194) 69/16 (167) HEAD (74) 13/32 (28) (74) 13/16 (30) Daylight SILL 31/8 (79) 13/8 (35) 31/8 (79) 13/8 (35) 49/16 S 6 9/16 S 13/32 (28) 19/16 (40) 49/16 (116) 5 21/32 (144) 69/16 (167) 75/8 (194) (74) Daylight (74) (74) Daylight (74) 1/06 3.14

SECTION DETAILS -- MULLIONS SCALE: 3I =1i0I MULLIONS 11/16 (27) 11/4 (32) 61/16 (154) 17/16 (37) 21/2 (63) 2 11/16 (69) 57/8 (149) HORIZONTAL TRANSOM OVER OPERATING UNIT VERTICAL DOUBLE HUNG UNITS 2WIDE 11/4 (32) 11/16 (27) 61/16 (154) 17/16 (37) 21/2 (63) 31/8 (79) 57/8 (149) HORIZONTAL TRANSOM OVER PICTURE UNIT VERTICAL PICTURE UNIT 2WIDE 11/16 (18) GRILLES 3/4 (19) ALUMINUM GRILLE BETWEEN GLASS WOOD REMOVABLE GRILLE 1/06 3.15

BAY 30_BAY UNIT HEAD SILL 1/2 (13) 30 DEGREE BAY - HEIGHT DIMENSIONS DOUBLE HUNG UNIT M.O. HEIGHT R.O. HEIGHT PICTURE UNIT 36 3--1 7/16 (951) 3--1 11/16 (957) N/A 40 3--5 7/16 (1052) 3--5 11/16 (1058) 40 48 4--1 7/16 (1256) 4--1 11/16 (1262) 48 52 4--5 7/16 (1357) 4--5 11/16 (1363) 52 56 4--9 7/16 (1459) 4--9 11/16 (1465) 56 60 5--1 7/16 (1560) 5--1 11/16 (1567) 60 64 5--5 7/16 (1662) 5--5 11/16 (1668) 64 68 5--9 7/16 (1764) 5--9 11/16 (1770) 68 72 6--1 7/16 (1865) 6--1 11/16 (1871) N/A 76 6--5 7/16 (1967) 6--5 11/16 (1973) N/A Structural support members supplied by others. 30_ BAY Scale: 1 1/2I =1i-0I to Projection Corner ITDH22-19 7/8 (505) ITDH26-23 5/16 (592) ITDH30-26 25/32 (681) ITDH34-30 1/4 (769) ITDH36-32 (813) ITDH38-33 23/32 (857) Projection Corner to Projection Corner ITDH22-23 15/16 (608) ITDH26-27 15/16 (710) ITDH30-31 15/16 (811) ITDH34-35 15/16 (913) ITDH36-37 15/16 (964) ITDH38-39 15/16 (1014) ITDH42-43 15/16 (1116) 49/16 (116) 1/4 (6) Projection 30 1/4 (6) 30_ BAY - Double Hung center Scale: 3I =1i -0I Masonry Exterior of Sheathing 3.16

BAY 30_BAY UNITS 30 DEGREE DOUBLE HUNG BAY - WIDTH DIMENSIONS UNIT # M.O. WIDTH R.O. WIDTH PROJECTION UNIT # M.O. WIDTH R.O. WIDTH PROJECTION 22 WIDE UNITS 30 WIDE UNITS 22-22 -22 5--4 7/8 (1648) 5--3 11/16 (1618) 11 3/8 (289) 30-30 -30 7--2 3/4 (2203) 7--1 17/32 (2172) 15 3/8 (391) 22-26 -22 5--8 7/8 (1719) 5--7 11/16 (1719) 11 3/8 (289) 30-34 -30 7--6 3/4 (2305) 7--5 17/32 (2274) 15 3/8 (391) 22-30 -22 6--0 7/8 (1851) 5--11 11/16 (1821) 11 3/8 (289) 30-36 -30 7--8 3/4 (2356) 7--7 17/32 (2325) 15 3/8 (391) 22-34 -22 6--4 7/8 (1953) 6--3 11/16 (1922) 11 3/8 (289) 30-38 -30 7--10 3/4 (2407) 7--9 17/32 (2376) 15 3/8 (391) 22-36 -22 6--6 7/8 (2003) 6--5 11/16 (1973) 11 3/8 (289) 30-42 -40 8--2 3/4 (2508) 8--1 17/32 (2477) 15 3/8 (391) 22-38 -22 6--8 7/8 (2054) 6--7 11/16 (2024) 11 3/8 (289) 30-50 -30 8--10 3/4 (2711) 8--9 17/32 (2680) 15 3/8 (391) 22-42 -22 7--0 7/8 (2156) 6--11 11/16 (2126) 11 3/8 (289) 30-54 -30 9--2 3/4 (2813) 9--1 17/32 (2782) 15 3/8 (391) 22-50 -22 7--8 7/8 (2359) 7--7 11/16 (2329) 11 3/8 (289) 34 WIDE UNITS 22-54 -22 8--0 7/8 (2461) 7--11 11/16 (2430) 11 3/8 (289) 34-34 -34 8--1 21/32 (2480) 8--0 15/32 (2450) 17 3/8 (441) 22-62 -22 8--8 7/8 (2664) 8--7 11/16 (2634) 11 3/8 (289) 34-36 -34 8--3 21/32 (2531) 8--2 15/32 (2501) 17 3/8 (441) 26 WIDE UNITS 34-38 -34 8--5 21/32 (2582) 8--4 15/32 (2560) 17 3/8 (441) 26-26 -26 6--3 13/32 (1915) 6--2 19/32 (1895) 13 3/8 (340) 34-42 -34 8--9 21/32 (2684) 8--8 15/32 (2654) 17 3/8 (441) 26-30 -26 6--7 13/32 (2017) 6--6 19/32 (1996) 13 3/8 (340) 34-50 -34 9--5 21/32 (2887) 9--4 15/32 (2857) 17 3/8 (441) 26-34 -26 6--11 13/32 (2119) 6--10 19/32 (2098) 13 3/8 (340) 36 WIDE UNITS 26-36 -26 7--1 13/32 (2169) 7--0 19/32 (2149) 13 3/8 (340) 36-36 -36 8--7 1/8 (2619) 8--5 15/16 (2589) 18 3/8 (467) 26-38 -26 7--3 13/32 (2220) 7--2 19/32 (2199) 13 3/8 (340) 36-38 -36 8--9 1/8 (2670) 8--7 15/16 (2640) 18 3/8 (467) 26-42 -26 7--7 13/32 (2322) 7--6 19/32 (2301) 13 3/8 (340) 36-42 -36 9--1 1/8 (2772) 8--11 15/16 (2742) 18 3/8 (467) 26-50 -26 8--3 13/32 (2525) 8--2 19/32 (2504) 13 3/8 (340) 38 WIDE UNITS 26-54 -26 8--7 13/32 (2627) 8--6 19/32 (2606) 13 3/8 (340) 38-38 -38 9--0 19/32 (2758) 8--11 3/8 (2727) 19 3/8 (492) 26-62 -26 9--3 13/32 (2830) 9--2 19/32 (2809) 13 3/8 (340) 38-42 -38 9--4 19/32 (2860) 9--3 3/8 (2829) 19 3/8 (492) NOTE: Factory assembled bay units include head and seat boards. Structural support members and interior trim supplied by others. to Projection Corner ITDH22-19 7/8 (505) ITDH26-23 5/16 (592) ITDH30-26 25/32 (681) ITDH34-30 1/4 (769) ITDH36-32 (813) ITDH38-33 23/32 (857) Projection Corner to Projection Corner ITDHP28-39 15/16 (1014) ITDHP42-43 15/16 (1116) ITDHP50-51 15/16 (1319) ITDHP54-55 15/16 (1421) ITDHP62-63 15/16 (1624) 49/16 (116) 1/4 (6) Projection 1/4 (6) 30_ BAY - Picture Center Unit Scale: 3I =1i -0I Masonry Exterior of Sheathing 3.17

BAY 45_BAY UNITS 1/2 (13) HEAD SILL 45 DEGREE BAY - HEIGHT DIMENSIONS DOUBLE HUNG UNIT M.O. HEIGHT R.O. HEIGHT PICTURE UNIT 36 3--1 7/16 (951) 3--1 11/16 (957) N/A 40 3--5 7/16 (1052) 3--5 11/16 (1058) 40 48 4--1 7/16 (1256) 4--1 11/16 (1262) 48 52 4--5 7/16 (1357) 4--5 11/16 (1363) 52 56 4--9 7/16 (1459) 4--9 11/16 (1465) 56 60 5--1 7/16 (1560) 5--1 11/16 (1567) 60 64 5--5 7/16 (1662) 5--5 11/16 (1668) 64 68 5--9 7/16 (1764) 5--9 11/16 (1770) 68 72 6--1 7/16 (1865) 6--1 11/16 (1871) N/A 76 6--5 7/16 (1967) 6--5 11/16 (1973) N/A Structural support members supplied by others. 45_ BAY Scale: 1 1/2I =1i - 0I to Projection Corner ITDH22-16 21/32 (423) ITDH26-19 1/2 (495) ITDH30-22 5/16 (567) Projection Corner to Projection Corner ITDH22-25 9/32 (642) ITDH26-29 9/32 (744) ITDH30-33 9/32 (845) ITDH34-37 9/32 (947) ITDH36-39 9/32 (998) ITDH38-41 9/32 (1049) ITDH42-45 9/32 (1150) 49/16 (116) 1/4 (6) Projection 1/4 (6) 45 Exterior of Sheathing 45_ BAY - Double Hung center Scale: 3I =1i -0I Masonry 3.18

BAY 45_BAY UNITS 45 DEGREE DOUBLE HUNG BAY - WIDTH DIMENSIONS UNIT # M.O. WIDTH R.O. WIDTH PROJECTION UNIT # M.O. WIDTH R.O. WIDTH PROJECTION 22 WIDE UNITS 30 WIDE UNITS 22-22 -22 5--0 13/32 (1534) 4--10 19/32 (1488) 16 9/16 (423) 30-30 -30 6--7 23/32 (2025) 6--5 15/16 (1980) 22 7/32 (564) 22-26 -22 5--4 13/32 (1636) 5--2 19/32 (1590) 16 9/16 (423) 30-34 -30 6--11 23/32 (2126) 6--9 15/16 (2081) 22 7/32 (564) 22-30 -22 5--8 13/32 (1738) 5--6 19/32 (1691) 16 9/16 (423) 30-36 -30 7--1 23/32 (2177) 6--11 15/16 (2132) 22 7/32 (564) 22-34 -22 6--0 13/32 (1839) 5--10 19/32 (1793) 16 9/16 (423) 30-38 -30 7--3 23/32 (2228) 7--1 15/16 (2183) 22 7/32 (564) 22-36 -22 6--2 13/32 (1890) 6--0 19/32 (1844) 16 9/16 (423) 30-42 -40 7--7 23/32 (2330) 7--5 15/16 (2284) 22 7/32 (564) 22-38 -22 6--4 13/32 (1941) 6--2 19/32 (1895) 16 9/16 (423) 30-50 -30 8--3 23/32 (2533) 8--1 15/16 (2488) 22 7/32 (564) 22-42 -22 6--8 13/32 (2042) 6--6 19/32 (1996) 16 9/16 (423) 30-54 -30 8--7 23/32 (2634) 8--5 15/16 (2589) 22 7/32 (564) 22-50 -22 7--4 13/32 (2246) 7--2 19/32 (2199) 16 9/16 (423) 30-62 -30 9--3 23/32 (2838) 9--1 15/16 (2792) 22 7/32 (564) 22-54 -22 7--8 13/32 (2347) 7--6 19/32 (2301) 16 9/16 (423) 22-62 -22 8--4 13/32 (2550) 8--2 19/32 (2504) 16 9/16 (423) 26 WIDE UNITS 26-26 -26 5--10 1/16 (1780) 5--8 9/32 (1734) 19 3/8 (492) 26-30 -26 6--2 1/16 (1881) 6--0 9/32 (1836) 19 3/8 (492) 26-34 -26 6--6 1/16 (1983) 6--4 9/32 (1938) 19 3/8 (492) 26-36 -26 6--8 1/16 (2034) 6--6 9/32 (1988) 19 3/8 (492) 26-38 -26 6--10 1/16 (2084) 6--8 9/32 (2039) 19 3/8 (492) 26-42 -26 7--2 1/16 (2186) 7--0 9/32 (2141) 19 3/8 (492) 26-50 -26 7--10 1/16 (2389) 7--8 9/32 (2344) 19 3/8 (492) 26-54 -26 8--2 1/16 (2491) 8--0 9/32 (2446) 19 3/8 (492) 26-62 -26 8--10 1/16 (2694) 8--8 9/32 (2649) 19 3/8 (492) NOTE: Factory assembled bay units include head and seat boards. Structural support members and interior trim supplied by others. to Projection Corner ITDH22-16 21/32 (423) ITDH26-19 1/2 (495) ITDH30-22 5/16 (567) Projection Corner to Projection Corner ITDHP38-41 9/32 (1049) ITDHP42-45 9/32 (1150) ITDHP50-51 9/32 (1353) ITDHP54-55 9/32 (1455) ITDHP62-63 9/32 (1658) 49/16 (116) 1/4 (6) Projection 1/4 (6) 45 Exterior of Sheathing 45_ BAY - Picture Center Unit Scale: 3I =1i -0I Masonry 3.19

INSTALLATION SUGGESTION Scale 3I =1i 0I 1/4 (6) 1/2 (13) HEAD Masonry SILL 1/2 (13) 1/4 (6) Masonry BRICK VENEER WITH STEEL FRAME CONSTRUCTION NOTE: The above wall sections represent typical wall conditions, these details are not intended as installation instructions. Please refer to the installation instructions provided with the purchased units. NOTE: Picture unit Installation similar. 3.20

INSTALLATION SUGGESTION Scale 3I =1i 0I 1/2 (13) HEAD SILL 1/2 (13) NOTE: Double Hung Unit shown with jamb extension. WOOD SIDING WITH 2X6 FRAME CONSTRUCTION Picture unit Installation similar. NOTE: The above wall sections represent typical wall conditions, these details are not intended as installation instructions. Please refer to the installation instructions provided with the purchased units. 3.21

INSTALLATION SUGGESTIONS Scale 3I =1i 0I HEAD 1/2 (13) SILL 1/2 (13) STUCCO WITH 2X4 FRAME CONSTRUCTION NOTE: Picture Unit Installation similar. NOTE: The above wall sections represent typical wall conditions, these details are not intended as installation instructions. Please refer to the installation instructions provided with the purchased units. 3.22