Temposonics. Magnetostrictive Linear Position Sensors. MH-Series Flexible MH Installation Manual

Similar documents
Temposonics Magnetostrictive Linear Position Sensors. Temposonics GB-Series Brief Instructions

Temposonics. Magnetostrictive Linear Position Sensors. MHRM Analog Data Sheet. For embedded or externally threaded installation

Temposonics Magnetostrictive Linear Position Sensors. Temposonics E-Series Brief Instructions

Temposonics. Magnetostrictive Linear Position Sensors. MH-Series MH5 Analog Data Sheet

Temposonics. Magnetostrictive Linear Position Sensors. R-Series Profinet IO RT Operation Manual

Temposonics. MH-Series Analog Redundant. Absolute, Non-Contact Positions Sensors. Temposonics MT Measuring length mm

Temposonics. Absolute, Non-Contact Position Sensors. MH Series. Temposonics MB Analog. Technical Data / Description

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

Temposonics. Absolute, Non-Contact Position Sensors. MH Series. Temposonics MH Analog /Digital. Technical Data / Description

Temposonics. M-Series Analog Redundant. Absolute, Non-Contact Positions Sensors. Temposonics MT Measuring length mm

Temposonics. Magnetostrictive Linear Position Sensors. GB-Series Analog Operation Manual

Temposonics. Magnetostrictive Linear Position Sensors. TH CANbus Data Sheet

Temposonics. Absolute, Non-Contact Position Sensors. MH Series. Temposonics MH 200. Technical Data / Description. Compact sensor for mobile hydraulics

Temposonics. Magnetostrictive Linear Position Sensors. TH Analog Data Sheet

Temposonics. M-Series PWM. Absolute, Non-Contact Position Sensors. Temposonics MH Measuring Length mm. Document Number Revision B

Temposonics. M-Series Analogue / SIL2* Absolute, Non-Contact Position Sensors. Temposonics MH Measuring Length mm

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

Temposonics. M-Series Analog. Magnetostrictive Position Sensors. Temposonics MH Measuring length mm SENSORS

Level Plus. Magnetostrictive Liquid Level Transmitters with Temposonics Technology. LP-Series SE Replacement Installation Manual

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

Temposonics. Magnetostrictive Linear Position Sensors. TH Analog SIL 2 capable Data Sheet

Temposonics. M-Series Analog. Absolute, Non-Contact Position Sensors. Temposonics MH Measuring length mm. Compact Sensor for Mobile Hydraulics

Temposonics. Magnetostrictive, Absolute, Non-contact Linear-Position Sensors. R-Series Models RP and RH DeviceNet Output.

Temposonics. Magnetostrictive Linear Position Sensors. R-Series Ethernet/IP TM Operation Manual

R-Series Rod Model RS. Data Sheet. Model RS Rod-style sensor with IP68/IP69K Super Shield Housing. Interrogation Return wire.

Temposonics. G-Series Analog Redundant. Magnetostrictive Position Sensors. Redundancy for enhanced safety

PRODUCT SELECTOR GUIDE

PRODUCT SELECTOR GUIDE

Temposonics. E-Series Analog + Start / Stop. Magnetostrictive Position Sensors. Temposonics EP Measuring range mm / mm SENSORS

Temposonics GENERATION THE NEW I AM. Magnetostrictive Linear Position Sensors. Temposonics R-Series V Profinet RT & IRT Operation Manual

Temposonics. G-Series Analog or Start/Stop. Absolute, Non-Contact Position Sensors. Temposonics GP and GH Stroke length mm depends on output

Temposonics. Magnetostrictive, Absolute, Non-contact Linear-Position Sensors. R-Series Models RP and RH Ethernet POWERLINK.

CANBUS G. Up to mm ( in.) < ± 0.01% of full stroke or ± 0.04 mm ( in.), whichever is greater*

Temposonics. R-Series DeviceNet. Magnetostrictive Position Sensors. Intelligent Design. Temposonics RP and RH Measuring length mm SENSORS

Temposonics. Magnetostrictive Linear Position Sensors. E-Series IO-Link Operation Manual

ANALOG. PARAMETER SPECIFICATION Measured Variable: Displacement, Velocity (magnitude only) 16 bit or mm, whichever is greater

Temposonics. Magnetostrictive Linear Position Sensors. DATA SHEET GBS Analog

SSI. Synchronous Serial Interface

Temposonics. Magnetostrictive Linear-Position Sensors. R-Series Model RP and RH Sensors Synchronous Serial Interface (SSI) Output D

Temposonics ATEX. Magnetostrictive Linear Position Sensors. DATA SHEET High Pressure Housing (HPH) The Measurable Difference

Angle sensor AN2 series 30

Temposonics. Magnetostrictive Linear Position Sensors

L E V E L P L U S M - S E R I E S ANALOG

Temposonics. Absolute, Non-Contact Position Sensors. OPERATION MANUAL R-Serie Analog. The Measurable Difference

Temposonics. Magnetostrictive Linear Position Sensors

BODAS Pressure sensor PR3 series 10

Part No Rev. E

958A Compact. Series 958 Compact Housing LDT. Housing ABSOLUTE PROCESS CONTROL KNOW WHERE YOU ARE... REGARDLESS

958A Compact Housing Linear Displacement Transducer

Pressure relief valve

Profibus-DP Output. Profibus-DP output: Standard Profibus-DP signal. Profibus Output

Angle Sensor WS1. RE Edition: Replaces:

Directional servo-valve of 4-way design

Your Global Automation Partner. LTX Linear Position Sensors with SSI Interface. Operating instructions

INSTRUCTION MANUAL. I/P Converter DSG BXXY3Z DSG BXXY4Z

Contamination switch VS

ENC 150 REFERENCE MANUAL ACU-RITE

JUMO DELOS SI. Precision pressure transmitter with switching contacts and display. Application. Brief description. Key features.

P1A Pressure Sensor. Description. Features. Applications MAIN FEATURES

0 to 100 up to 0 to PSI (gage) Packard Electric Metri-Pack 150 Series, M12-4 Pole* 1/4-18 NPT ma, VDC, 0-5 VDC, 0-10 VDC

Electronic Pressure Switches

A Member of the. Integrated Metering Technologies

Magnetostriction in Automotive Position Measurement

NOTE Please read this Operating Manual carefully before first using the device and strictly adhere to the instructions!

A Member of the. Integrated Metering Technologies

Data Sheet P1A Pressure Sensor

Series 7000 Torque Sensor for PTO-shafts

Pressure transmitters for heavy-duty applications MBS 2000 and MBS 2050

Temposonics Absolute, Non-Contact Position Sensors

P500 Pressure Sensor. Description. Features. Applications MAIN FEATURES

Technical Documentation

Electronic Pressure Switches

Series 7000 Torque Sensor for PTO-shafts

Lexium integrated drives

ACTUATORS POSITION SENSOR

Temposonics. R-Serie Catalog. 0.5 μm. Absolute, Non-Contact Position Sensors. The Measurable Difference

High temperature pressure transmitters for heavy-duty applications MBS 2200 and MBS 2250

4-way directional servo-valve

Digital Pressure Regulator Sentronic PLUS Series 614

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE

DL 01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

OBSOLETE. Data Sheet P1E Oxygen Service Pressure Sensor. Main Features. Typical Applications. Attributes. Description

Temposonics. R-Series Analog. Absolute, Non-Contact Position Sensors. Temposonics RP and RH Measuring length mm

Contactless Encoder with Stainless Steel Housing Incremental: ppr RI360P0-EQR24M0- INCRX2-H1181

BODAS Pressure sensor PR3 series 10

Differential Pressure Sensors

TECHNICAL PAPER. Magnetostrictive Position Transducers in Medical Applications. David S. Nyce. Introduction

958A Embedded Linear Displacement Transducer. THEINSIDER the most trusted information comes from INSIDE

Dual Channel Speed Sensor GEL 2475

User Manual Rittal PMC UPS 6kVA

Pressure transmitter for general purpose Type MBS 1700 and MBS 1750

INSTRUCTION MANUAL Oil level with pointer indicator

Pressure Transmitter for wind turbine applications MBS 8200 and MBS 8250

Temposonics Magnetostrictive Linear-Position Sensors

Linear unit, pneumatic KHM 40

NEOTECHA NTB-NTC BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Flowmeter Ultrasonic Flow Metering / Dosing Device. Operating Manual

2-way proportional throttle valve for block installation

Lexium integrated drives

Transcription:

Temposonics Magnetostrictive Linear Position Sensors MH-Series Flexible MH

Operation Manual Table of contents 1. Introduction... 3 1.1 Purpose and use of this manual... 3 1.2 Used symbols and warnings... 3 2. Safety instructions... 3 2.1 Intended use... 3 2.2 Forseeable misuse... 3 2.3 Installation, commissioning and operation... 4 2.4 Safety instructions for use in explosion-hazardous areas... 4 2.5 Warranty... 4 2.6 Return... 4 3. Identification... 5 3.1 Order code of Flexible MH analog... 5 3.2 Order code of Flexible MH CANbus... 6 3.3 Nameplate... 7 3.4 Scope of delivery... 7 4. Product description and commissioning... 7 4.1 Functionality and system design... 7 4.2 Styles and installation of Flexible MH... 8 4.3 Replacement of sensor... 10 4.3.1 FMH replacement parts... 10 4.3.2 FMH replacement parts... 11 4.4 Electrical connections... 14 4.5 Frequently ordered accessories... 15 5. Technical data...16 5.1 Technical data Flexible MH-Series analog... 16 5.2 Technical data Flexible MH-Series CANbus... 17 6. Appendix...18

1. Introduction 1.1 Purpose and use of this manual Before starting the operation of Temposonics position sensors, read this documentation thoroughly and follow the safety information. Keep the manual for future reference! The content of this technical documentation and of its annex is intended to provide information on mounting, installation and commissioning by qualified automation personnel 1 or instructed service technicians who are familiar with the project planning and dealing with Temposonics sensors. 1.2 Used symbols and warnings Warnings are intended for your personal safety and for avoidance of damage to the described product or connected devices. In this documentation, safety information and warnings to avoid danger that might affect the life and health of operating or service personnel or cause material damage are highlighted by the preceding pictogram which is defined below. 2.2 Forseeable misuse Foreseeable misuse Wrong sensor connection Operate the sensor out of the operating temperature range Power supply is out of the defined range Position measurement is influenced by an external magnetic field Cables are damaged Spacers are missing / installed in wrong order Wrong connection of ground / shield Use of a magnet that is not certified by MTS Sensors Consequence The sensor will not work properly or can be damaged No signal output The sensor can be damaged Signal output is wrong / no signal output / the sensor can be damaged Signal output is wrong Short circuit the sensor can be destroyed / sensor does not respond Error in position measurement Signal output is disturbed The electronics can be damaged Error in position measurement Symbol NOTICE Meaning This symbol is used to point to situations that may lead to material damage, but not to personal injury. Do not reprocess the sensor afterwards. The sensor might be damaged. 2. Safety instructions 2.1 Intended use This product may be used only for the applications defined under item 1 and only in conjunction with the third-party devices and components recommended or approved by MTS Sensors. As a prerequsite of proper and safe operation: the product requires correct transport, storage, mounting and commissioning and must be operat ed with utmost care. Do not step on the sensor. The sensor might be damaged. 1. The sensor systems of all Temposonics series are intended exclu sively for measurement tasks encountered in industrial, commercial and laboratory applications. The sensors are considered as system accessories and must be connected to suitable evaluation electron ics, e.g. a PLC, IPC, indicator or other electronic control unit. 1/ The term qualified technical personnel characterizes persons who: are familiar with the safety concepts of automation technology applicable to the particular project, are competent in the field of electromagnetic compatibility (EMC), have received adequate training for commissioning and service operations are familiar with the operation of the device and know the information required for correct operation provided in the product documentation. I 3 I

2.3 Installation, commissioning and operation The position sensors must be used only in technically safe condition. To maintain this condition and to ensure safe operation, installation, connection and service, work may be performed only by qualified technical personnel. If danger of injury to persons or of damage to operating equipment is caused by sensor failure or malfunction, additional safety measures such as plausibility checks, limit switches, EMERGENCY STOP systems, protective devices etc. are required. In the event of trouble, shut down the sensor and protect it against accidental operation. Safety instructions for commissioning To maintain the sensor operability, it is mandatory to follow the instructions given below. 1. Protect the sensor against mechanical damage during installation and operation. 2. Do not open or dismantle the sensor. 3. Connect the sensor very carefully and pay attention to the polarity of connections and power supply. 4. Use only approved power supplies. 5. It is indispensable to ensure that the specified permissible limit values of the sensor for operating voltage, environmental conditions, etc. are met. 6. Check the function of the sensor regularly and provide documentation of the checks. 7. Before applying power, ensure that nobody s safety is jeopardized by starting machines. 2.5 Warranty MTS Sensors grants a warranty period for the Temposonics position sensors and supplied accessories relating to material defects and faults that occur despite correct use in accordance with the intended application 2. The MTS Sensors obligation is limited to repair or replacement of any defective part of the unit. No warranty can be provided for defects that are due to improper use or above average stress of the product, as well as for wear parts. Under no circumstances will MTS Sensors accept liability in the event of offense against the warranty rules, no matter if these have been assured or expected, even in case of fault or negligence of the company. MTS Sensors explicitly excludes any further warranties. Neither the company s representatives, agents, dealers nor employees are authorized to increase or change the scope of warranty. 2.6 Return For diagnostic purposes, the sensor can be returned to MTS Sensors. Any shipment cost is the responsibility of the sender 2. For a corresponding form, see chapter "6. Appendix" on page 18. 2.4 Safety instructions for use in explosion-hazardous areas The sensor is not suitable for operation in explosion-hazardous areas. 2/ See also applicable MTS Sensors sales and delivery on www.mtssensors.com I 4 I

3. Identification 3.1 Order code of Flexible MH analog 1 2 3 4 5 6 7 8 9 10 11 12 13 14 F M H M 3 a b c d e f a Sensor model F M H Flexible MH b A B Z Design M33 thread flange, flat end plug M33 thread flange, M4 female plug Base unit (for replacement) c Stroke length X X X X M 0500 5000 mm (20 mm increments) d Pin assignment M12 connector (VDC - GND - SIG) E M12 connector (E: 2-3-4) G M12 connector (G: 1-3-4) H M12 connector (H: 1-3-2) e Operating voltage 3 +12 / 24 VDC (8 32 VDC) f Output V 1 1 0.25 4.75 VDC V 1 2 0.5 4.5 VDC V 1 3 4.75 0.25 VDC V 1 4 4.5 0.5 VDC A 0 1 4 20 ma A 0 4 20 4 ma I 5 I

3.2 Order code of Flexible MH CANbus 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 F M H M F 3 0 1 a b c d e f g h a Sensor model F M H Flexible MH b A B Z Design M33 thread flange, flat end plug M33 thread flange, M4 female plug Base unit (for replacement) c Stroke length X X X X M 0500 5000 mm (20 mm increments) d Pin assignment M12 connector (VDC - GND - CAN_HI - CAN_LO) F M12 connector (F: 2-3-4-5) e Operating voltage 3 +12 / 24 VDC (8 32 VDC) f Output C 0 1 CANopen J 0 1 SAE J1939 g Baud rate setting CANopen 0 1000 kbit/s 1 800 kbit/s 2 500 kbit/s 3 250 kbit/s (default) 4 125 kbit/s SAE J1939 3 250 kbit/s (fix setting) h Node ID CANopen 7 F Node ID (hex): 01 7F (default: 7F) SAE J1939 F D Node ID (hex): 01 FD (default: FD) I 6 I

3.3 Nameplate 3.4 Scope of delivery Flexible MH analog/digital: Sensor O-ring Fig. 1: Example of nameplate Order code Flexible MH Sensor Element: Sensor element Lid M5 12 screws (3 ) M2.5 12 screws (2 ) Sensor element bracket Gasket 4. Product description and commissioning 4.1 Functionality and system design Product designation Position sensor Temposonics MH-Series Position magnet (Magnetic field) 2 1 Sensor model (rod sensor) Stroke length 500 5000 mm Sensing element (Waveguide) Torsional strain pulse converter 3 4 5 Output signal Analog CANopen SAE J1939 Principle of operation and system construction The absolute, linear position sensors provided by MTS Sensors rely on the company s proprietary Temposonics magnetostrictive technology, which can determine position with a high level of precision and robustness. Each Temposonics position sensor consists of a ferromagnetic waveguide, a position magnet, a strain pulse converter and supporting electronics. The magnet, connected to the object in motion in the application, generates a magnetic field at its location on the waveguide. A short current pulse is applied to the waveguide. This creates a momentary radial magnetic field and torsional strain on the waveguide. The momentary interaction of the magnetic fields releases a torsional strain pulse that propagates the length of the waveguide. When the ultrasonic wave reaches the end of the waveguide it is converted into an electrical signal. Since the speed of the ultrasonic wave in the waveguide is precisely known, the time required to receive the return signal can be converted into a linear position measurement with both high accuracy and repeatability. Measurement Cycle 1 Current pulse generates magnetic field 2 Interaction with position magnet field generates torsional strain pulse 3 Torsional strain pulse propagates 4 Strain pulse detected by converter 5 Time-of-flight converted into position Fig. 2: Principle of operation: Time-based magnetostrictive position sensing principle Modular mechanical and electronic construction The sensor rod protects the inner sensor element. The sensor electronics housing, a rugged stainless steel construction, contains the complete electronic interface with active signal conditioning. The external position magnet is a permanent magnet. It travels along the sensor rod and triggers the measurement through the sensor rod wall. The sensor can be connected directly to a control system. Its electronics generates a strictly position-proportional signal output between zero and end position. I 7 I

4.2 Styles and installation of Flexible MH FMH with flat end plug A/F 60 Sensor electronics housing 29 Null zone 38.9 Stroke length 500 5000 Dead zone 84.8 15 M12 1-6g 65 Magnet R32.5 Threaded flange M33 2-6g Sensor rod Ø12.7 FMH with M4 female thread plug A/F 60 Sensor electronics housing 29 Null zone 38.9 Stroke length 500 5000 Dead zone 90.5 15 M12 1-6g 65 Magnet 6 R32.5 Threaded flange M33 2-6g Sensor rod Ø12.7 M4 female thread All dimensions in millimeters Fig. 3: Temposonics FMH with ring magnet I 8 I

Installation of a rod-style sensor in a fluid cylinder The rod-style version has been developed for direct stroke measurement in a fluid cylinder. Mount the sensor via threaded flange. Use non-magnetic material for mounting support. Mounted on the face of the piston, the position magnet travels over the rod without touching it and indicates the exact position through the rod wall independent of the hydraulic fluid. The pressure resistant sensor rod is installed into a bore in the piston rod. Step 1 Cavity Dimensions Notice for metric threaded flanges Thread (d 1 P) d 2 d 3 d 4 +0.1 0 L 1 +0.4 0 L 2 L 3 L 4 Z M33 2-6g 72 33 35.4 3.1 24 2.5 24 15 L 3 R 0.4 max. Ra 0.2 Ra 0.1 Pitch diameter A Ød 4 Ra 3.2 Z 0.2 A L 1 45 ±5 ±1 A Ød 2 0.2 A Applies at Ød 4 1. Insert sensor into cylinder Be careful not to drop or cause impact to the sensor 2. Screw the sensor into the cylinder by hand (< 10 Nm) 3. Stop rotation when sensor is flush with the cylinder (do not use much force in step 2. It should screw in smoothly) Step 2 All dimensions in mm L 2 Ød 3 L 4 (Reference size) Thread (d 1 P) This dimension applies when tap drill cannot pass through entire boss Fig. 4: Cavity dimensions for metric threaded flange M33 2-6h Tighten sensor to a torque of 310 Nm Fig. 5: Sensor in fluid cylinder Hydraulics sealing To seal the flange contact surface: A sealing via an O-ring in the undercut via O-ring 29.6 2.9 mm (part no. 561 968) In the case of threaded flange M33 2-6h, provide a screw hole based on ISO 6149-1. See ISO 6149-1 for further information. Note the fastening torque of 310 Nm. Seat the flange contact surface completely on the cylinder mounting surface. The cylinder manufacturer determines the pressure-resistant gasket (copper gasket, O-ring, etc.). The position magnet should not rub on the sensor rod. The piston rod drilling (Ø 12.7 mm rod: Ø 16 mm) depends on the pressure and piston speed. Adhere to the information relating to operating pressure. Protect the sensor rod against wear. I 9 I

4.3 Replacement of sensor The sensor element of the sensor is replaceable. The sensor can be replaced without interrupting the hydraulic circuit. 4.3.1 FMH replacement parts Lid Lid (1 ) Protective cap Sensor element Sensor element (1 ) Protective cap M5 12 screw M2 12 screw M5 12 (3 ) Screws are for mounting lid to housing M2.5 10 (2 ) Screws are for mounting sensor element to housing Bracket Sensor element bracket (1 ) Mounting sensor element to housing Gasket Gasket (1 ) Replace old gasket with new gasket Loctite 242 Fig. 6: FMH replacement parts I 10 I

4.3.2 FMH replacement steps Step 1: Remove endcaps Remove Remove Step 2: Remove lid Step 2 A Remove three screws (M5 12 mm) with 4 mm hex key Step 2 B Insert screws into threaded holes in lid to aid lid removal Step 2 C Spin screw one in (clockwise) with two rotations Spin screw two (any other screw) in (clockwise) with two rotations Spin screw three (last, remaining screw) in (clockwise) with two rotations Repeat the above steps until all 3 screws are fully inserted Step 2 D Pull lid out from behind flange M5 12 threaded holes are for removing lid from housing Holes without threads are for installating sensor into cylinder Fig. 7: FMH replacement steps I 11 I

Step 3: Remove old sensor element Step 3 A Slowly remove lid entirely Be careful not to damage PCB or wires Step 3 B Unplug sensor element from PCB in lid Pull straight out Grip the connector. Do not pull on wires. Step 3 C Remove the M2.5 10 mm screws with 1.5 mm hex key or #1 Phillips (cross) Remove sensor element Take care not to bend sensor element (< 200 mm) Remove M2.5 screws, use 1.5 hex wrench or #1 Phillips (cross) Min = 205 mm Min = 200 mm Fig. 8: FMH replacement steps I 12 I

Step 4: Install new sensor element Step 4 A Insert new sensor element into sensor cavity be careful not to bend the sensor element more than 200 mm radius Min = 205 mm Pins should be aligned correctly Step 4 B Apply one drop of Loctite 242 to each screw thread Tighten sensor screws (M2.5 10 mm) to 0.27 Nm (±0.06 Nm) with 1.5 mm hex key or #1 Phillips (cross) Tighten M2.5 12 mm screws Min = 200 mm Step 4 C Plug wires from sensor element into PCB Step 4 D Unscrew all three M5 12 mm screws, with 4 mm hex key from lid save screws for step 5 B Fig. 9: FMH replacement steps Step 5: Install lid Step 5 A Insert lid into sensor cavity Align the lid through holes with the sensor cavity threaded holes Step 5 B Apply Loctite 242 to each screw Insert M5 12 mm screws into lid through holes Screw all three screws to housing's threads torque M5 screws to 5.9 Nm (±0.3 Nm) with 4 mm hex key Use 15 mm flats to aid alignment Lid thru all (3 ) Fig. 10: FMH replacement steps I 13 I

4.4 Electrical connections Placement of installation and cabling have decisive influence on the sensor s electromagnetic compatibility (EMC). Hence correct installation of this active electronic system and the EMC of the entire system must be ensured by using suitable metal connectors, shielded cables and grounding. Overvoltages or faulty connections can damage its electronics despite protection against wrong polarity. NOTICE 1. Do not mount the sensors in the area of strong magnetic or electric noise fields. 2. Never connect / disconnect the sensor when voltage is applied. Instructions for connection Use low-resistant twisted pair and shielded cables. Connect the shield to ground externally via the controller equipment. Keep control and signal leads separate from power cables and sufficiently far away from motor cables, frequency inverters, valve lines, relays, etc.. Use only connectors with metal housing and connect the shielding to the connector housing. Keep the connection surface at both shielding ends as large as possible. Connect the cable clamps to function as a ground. Keep all non-shielded leads as short as possible. Keep the earth connection as short as possible with a large cross section. Avoid ground loops. With potential differences between machine and electronics earth connections, no compensating currents are allowed to flow across the cable shielding. Recommendation: Install potential compensating leads with large cross section, or use cables with separate double shielding, and connect only one end of the shield. Use only stabilized power supplies in compliance with the specified connecting values. Analog output M12 connector 4 3 1 2 View on connector Fig. 11: Connector wiring analog CANbus output M12 connector 4 3 5 1 2 View on connector Pin E G H 1 do not connected VDC VDC 2 VDC do not connected SIG 3 GND GND GND 4 SIG SIG do not connected Pin Fig. 12: Connector wiring digital 1 not connected 2 VDC 3 GND 4 CAN_H 5 CAN_L F I 14 I

4.5 Frequently ordered accessories Position magnets Cord sets and adapter cables Ø 30.5 342 314 Ø 19.8 7.6 274 274 Ring magnet Part no. 402 316 Material: PA ferrite coated Weight: ca. 13 g Operating temperature: -40 +100 C Surface pressure: 20 N/mm 2 Test kits 4 pin M12 to DTM06 connector Part no. 254 597 M12 connector: Brass/Nickel DT connector: DTM06 3 pin Material: PVC Jacket Cable length: 275 mm Cable Ø: 5 mm Operating temperature: 40 +105 C 4 pin M12 to DT04 connector Part no. 254 600 M12 connector: Brass/Nickel DT connector: DT04 3 pin Material: PVC Jacket Cable length: 275 mm Cable Ø: 5 mm Operating temperature: 40 +105 C MH test kit (analog) Part no. 280 618 Kit includes: 12 VDC battery charger with adapter (EU & UK) Cable with M12 connector Cable with pigtailed wires Carrying case MH test kit (digital) for US Part no. 253 879 USB CAN-Modul Kit: - USB CAN-Modul - USB CAN-Modul Utility CD (driver & manual) USB cable cable with MTS M12 connector and RS232 connector cable with RS232 connector carrying case 12 VDC power supply MH test kit (digital) for EU / Asia Part no. 254 267 USB CAN-Modul Kit: - USB CAN-Modul - USB CAN-Modul Utility CD (driver & manual) USB cable cable with MTS M12 connector and RS232 connector cable with RS232 connector carrying case 12 VDC power supply Controlling design dimensions are in millimeters I 15 I

5. Technical data 5.1 Technical data Flexible MH-Series analog Output Signal characteristic Analog output restricted by noise or A/D converter of control unit Voltage 0.25 4.75 VDC / 0.5 4.5 VDC Current 4 20 ma Sample rate 2 ms Measured value Position Measurement parameters Resolution ±0.2 mm Linearity ±0.04 % (F.S.) Repeatability ±0.005 % (F.S.) Hysteresis ±0.2 mm Operating conditions Operating temperature 40 +105 C Humidity 90 % rel. humidity, no condensation Ingress protection IP67 / IP69K (with appropriate mating connection) Shock test IEC 60068-2-27, 100 g (6 ms) single shock, 50 g (11 ms) at 1000 shocks per axis Vibration test IEC 60068-2-64, 2 g (5 2000 Hz) EMC test & evaluation Mounting position Pressure (according to DIN EN ISO 19879)* PN (nominal operating) Pmax (max. overload) Pstatic (proof pressure) Design / Material ISO16750-2:2010 ISO 14982:2009 - Agricultural and forestry machinery ISO 13766:2006 - Earth-moving machinery EN 13309:2010 - Construction machinery RF immunity to 200 V/m per ISO 11452-2/-4 Any 350 bar 450 bar 625 bar Sensor electronics housing Stainless steel 1.4305 (AISI 303) Sensor rod with flange Stainless steel 1.4306 (AISI 304L) Stroke length 500 5000 mm Electrical installation Connection type M12 male plug Operating voltage 12 VDC (tolerance range 8 32 VDC) 24 VDC (tolerance range 8 32 VDC) Current consumption Typ. < 100 ma Typ. < 50 ma Load (output VDC) R L > 10 kω R L > 10 kω Load current (output VDC) Typ. 1 ma Typ. 1 ma Loud (output ma) R L < 250 Ω R L < 500 Ω Inrush current Max. 2.5 A / 2 ms Max. 4.5 A / 2 ms Supply voltage ripple < 1 % PP Power drain < 1 W Over voltage protection (GND-VDC) Up to +36 VDC Polarity protection (GND-VDC) Up to 36 VDC Insulation Resistance R 10 MΩ @ 60 sec Electric strength 500 VDC (DC GND to chassis GND) */ According to calculations under use of the FKM guideline Cycles Dynamic pressure: < 2 10 6 pressure cycles Static pressure: < 2 10 4 pressure cycles Proof pressure: Maximum 5 minutes testing time for cylinder pressure test Ø 12.7 mm sensor rod 350 bar 450 bar 625 bar I 16 I

5.2 Technical data Flexible MH-Series CANbus Output Interface CANopen / SAE J1939 Sample rate CANopen: 1 ms; SAE J1939: 20 ms Measured value Position Measurement parameters Resolution ±0.2 mm Linearity ±0.04 % (F.S.) Repeatability ±0.005 % (F.S.) Hysteresis ±0.2 mm Operating conditions Operating temperature 40 +105 C Humidity 90 % rel. humidity, no condensation Ingress protection IP67 / IP69K (with appropriate mating connection) Shock test IEC 60068-2-27, 100 g (6 ms) single shock, 50 g (11 ms) at 1000 shocks per axis Vibration test IEC 60068-2-64, 2 g (5 2000 Hz) EMC test Mounting position Pressure (according to DIN EN ISO 19879)* PN (nominal operating) Pmax (max. overload) Pstatic (proof pressure) Design / Material ISO16750-2:2010 ISO 14982:2009 - Agricultural and forestry machinery ISO 13766:2006 - Earth-moving machinery EN 13309:2010 - Construction machinery RF immunity to 200 V/m per ISO 11452-2/-4 Any 350 bar 450 bar 625 bar Sensor electronics housing Stainless steel 1.4305 (AISI 303) Sensor rod with flange Stainless steel 1.4306 (AISI 304L) Stroke length 500 5000 mm Electrical installation Connection type M12 male plug Operating voltage 12 VDC (tolerance range 8 32 VDC) 24 VDC (tolerance range 8 32 VDC) Current consumption Typ. < 100 ma Typ. < 50 ma Inrush current Max. 1.0 A @ 2 ms Max. 1.5 A @ 2 ms Bus termination (HI-LO) 120 Ω Supply voltage ripple < 1 % p-p Power drain < 1.5 W Over voltage proctection (GND-VDC) Up to +36 VDC Polarity protection (GND-VDC) Up to 36 VDC Insulation Resistance R 10 MΩ @ 60 sec. Electric strength 500 VDC (DC GND to chassis GND) Insulation Resistance R 10 MΩ @ 60 sec Electric strength 500 VDC (DC GND to chassis GND) */ According to calculations under use of the FKM guideline Cycles Dynamic pressure: < 2 10 6 pressure cycles Static pressure: < 2 10 4 pressure cycles Proof pressure: Maximum 5 minutes testing time for cylinder pressure test Ø 12.7 mm sensor rod 350 bar 450 bar 625 bar I 17 I

6. Appendix Safety Declaration Dear Customer, If you return one or several sensors for checking or repair, we need you to sign a safety declaration. The purpose of this declaration is to ensure that the returned items do not contain residues of harmful substances and / or that people handling these items will not be in danger. MTS Sensors order number: Sensor type(s): Serial number(s): Sensor length: The sensor has been in contact with the following materials: Don t specify chemical formulas. Please include safety data sheets of the substances, if applicable. In the event of suspected penetration of substances into the sensor, consult MTS Sensors to determine measures to be taken before shipment. Short description of malfunction: Corporate information Contact partner Company: Address: Name: Phone: E-Mail: We hereby certify that the measuring equipment has been cleaned and neutralized. Equipment handling is safe. Personnel exposure to health risks during transport and repair is excluded. Stamp Signature Date GERMANY MTS Sensor Technologie GmbH & Co.KG Auf dem Schüffel 9 58513 Lüdenscheid, Germany Tel. + 49-23 51-95 87 0 Fax. + 49-23 51-5 64 91 info.de@mtssensors.com www.mtssensors.com USA MTS Systems Corporation Sensors Division 3001 Sheldon Drive Cary, N.C. 27513, USA Tel. +1 919 677-0100 Fax +1 919 677-0200 info.us@mtssensors.com www.mtssensors.com

UNITED STATES MTS Systems Corporation Sensors Division GERMANY MTS Sensor Technologie GmbH & Co. KG ITALY Branch Office 3001 Sheldon Drive Cary, N.C. 27513 Phone: +1 919 677-0100 E-mail: info.us@mtssensors.com Auf dem Schüffel 9 58513 Lüdenscheid Phone: +49 2351 9587-0 E-mail: info.de@mtssensors.com Phone: +39 030 988 3819 E-mail: info.it@mtssensors.com Document Part Number: 551883 Revision A (EN) 10/2018 FRANCE Branch Office Phone: +33 1 58 4390-28 E-mail: info.fr@mtssensors.com GREAT BRITAIN Branch Office Phone: +44 79 44 15 03 00 E-mail: info.uk@mtssensors.com CHINA Branch Office Phone: +86 21 6485 5800 E-mail: info.cn@mtssensors.com JAPAN Branch Office Phone: +81 3 6416 1063 E-mail: info.jp@mtssensors.com www.mtssensors.com MTS, Temposonics and Level Plus are registered trademarks of MTS Systems Corporation in the United States; MTS SENSORS and the MTS SENSORS logo are trademarks of MTS Systems Corporation within the United States. These trademarks may be protected in other countries. All other trademarks are the property of their respective owners. Copyright 2018 MTS Systems Corporation. No license of any intellectual property rights is granted. MTS reserves the right to change the information within this document, change product designs, or withdraw products from availability for purchase without notice. Typographic and graphics errors or omissions are unintentional and subject to correction. Visit www.mtssensors.com for the latest product information.