WESAN WP 222. Bulk Water Meter Woltman

Similar documents
WESAN WP WOLTMAN METER

WESAN WPV E ELECTRONIC METER WOLTMAN

CORONA E ELECTRONIC METER MULTI-JET

HYDRUS ULTRASONIC METER

HYDRUS ULTRASONIC METER

CORONA ER ELECTRONIC METER MULTI-JET

SHARKY FS 473 ULTRASONIC FLOW SENSOR

RAY COMPACT ENERGY METER MECHANICAL

Domestic Water Meter. Elin Wasserwerkstechnik. Contact Water Meter MTM for cold water. Features

RAY MECHANICAL COMPACT METER. 4 MID approved class 2 from DN 15mm qp 0,6m3/h up to DN 40mm qp 10m3/h

US-S/FFL. Ultrasonic energy meters. Function. Flexible design. Connection. Mounting. High reliability

Variable Area Flow Meters

WSTH/WPTH. Woltmann type combined energy meter. Measuring distance. Function. Connection. High reliability. Mounting.

Residential Water Meters

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

display on the wall or in a panel away from the inline sensor SE30 for easy meter reading.

WSTH/WPTH. Woltmann type combined energy meter. Woltmann flow meters for large nominal flows combined with calculator and temperature sensors.

F 90 Heat Meter Warmly recommended to cool-headed economisers

TOPAS PMW-basic. Customer benefits. Product features

T O PA S Applications Features Your benefits

Installation Instruction Bulk water meter REMOVABLE ELEMENT WOLTMAN COLD (HOT) WATER METER MODEL: LXLC-50~500

Options guide. Electromagnetic flowmeters. M9xx

VZO Pressure drop curves See Meter data. Option: Reed pulser or RV / IN pulser

CONTOIL VZFA/VZOA , versions for higher requirements / applications

MWD. Industrial Temperature Assemblies RTD. Meassuring range ºC. Pt100 sensor class A, class B, class 1/3, class 1/10, or Cryogenic.

Water Metering THE WORLD S MOST ACCURATE COMMERCIAL HYBRID METER

Pipe surface resistance thermometer, for clamping Model TR57-M, miniature design

N086, N186, N786. Pressure retaining valve, Plastic

EW130 Series Multijet Water Meters DN15 40 FOR COLD AND WARM POTABLE WATER APPLICATIONS

Inline Flow meter for compressed air and gases DN15 (1/2 ) - DN80 (3 )

Measuring capsule heat meter G54 / G55

BGN. All Metal Variable Area Flow Meter. Technical Data Sheet

MidFlow _ 135. Sliding Vane Meters DN (1-2 ) Model PT / Fuel Oil Flowmeters135. Product Bulletin

Pressure gauge in stainless steel version. Suitable for aggressive media and environments. Aluminium, white with black lettering

The EPSILON is based on the principle of measuring velocity in the pipe line, therefore the flow measurement is volumetric.

Design and application

Operation Manual Woltman. Operation Manual WOLTMAN Water Meters

WZMC-402 Ultrasonic Apartment Energy Meters

Differential Pressure Gauges (701P Series)

WATER METERS.

Supplementary instructions Flanges according to DIN - EN - ASME - JIS - GOST Technical data. Document ID: 31088

mass flowmeter for compressed air

Volumeter. RMG Meßtechnik GmbH. Publication No E

Resistance thermometer For sanitary applications Model TR22-B, for orbital welding

ORIMAS Mass Flowmeter

Volumeter TRZ 03-K PRODUCT INFORMATION. Reliable Measurements of Gas

Quantometer MZ. Description

Metal tube variable area flowmeter for gases, liquids and steam

Flow VA 500/ 520. Flow sensors for compressed air and gases incl. temperature measurement. Verbrauch.

MX-SERIES OVAL GEAR FLOW METERS

SonoSensor 30 Ultrasonic flow sensor

AKF10+ Application. Types Available. Duct-/Immersion temperature sensor. Datasheet

Accessories for diaphragm seals Block flange and saddle flange Models , ,

SonoMeter 30 Energy Meters

EW447-EW452 Series Mechanical Heat Meters FOR HEATING AND COOLING APPLICATIONS

INSERTION flow sensor for continuous flow measurement

ProFlow TO BE REALLY SURE. Vane Meters. Experience in flow measurement. Introduction

aquaconcept Product features Customer benefits

TOPAS PMW-basic Hot water meter

Metering systems 0578EN January 2014 Thermal energy meters, ultrasounds type for use in a boiler room GE552-1 series

Resistance thermometer Model TR10-E, for additional thermowell

Electronic Water Meters in measuring cell design

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

Magnetic-inductive flow meter EPS / UMF2. Technical data sheet

A type Ejectors (in line) Dimensions and weights

STEEMCO Flowmeter for Steam

NORI 320 Globe valves PN DN Application Standard variants Operating data Materials Remarks Design

STEEMCO-MAS Flowmeter for Steam

Resistance Thermometers Model TR217, with Spring-Loaded Probe Tip

Oscillating piston flowmeters Series COVOL Positive displacement flowmeter for liquids

SonoMeter 30 Energy Meters

Domestic water meters

Datasheet PDCSY-MW-U. Technical Overview. Features. Product warranty and total quality commitment.

Orifice plate flowmeters Series PR By-pass flowmeter for liquids, gases and steam

HLX771/772. Inline Flowmeter for compressed air and gases DN15 (1/2 ) - DN80 (3 ) Typical Applications

TORRIX Magnetostrictive level sensor

ULTRASONIC FLOW SENSOR QALCOSONIC FLOW 2

Flowmeter DFM

Screw-type and measuring capsule heat meter with IrDA interface and an interface for retrofitting external modules or with integrated communication.

/ 855 / 857 / 861 / / 870 / 875 / 880 / 885. Variable Area Flowmeter, Plastic

KM-165, KM-185, KM-200 OVERVIEW. Flow Monitor & Flow Indicator. Features. Operation

GRUNDFOS alldos product information. The digital diaphragm dosing pump for difficult liquids

AKF10+ Application. Types Available. Duct-/Immersion temperature sensor. Datasheet

Accurate measurement of compressed air consumption and detection of leaks. Measuring the individual consumption per customer / cost centre

CONTOIL Fuel oil meters

mass flowmeter for compressed air

SITRANS P measuring instruments for pressure

VZ-01. Features. Oil Counter for Light to Heavy Fuel Oil. Description: Application: / Mounting on pressure or suction side

SMA. Automatic Minimum Flow System PN 250-PN 400 ANSI look at info overview. 180 bar < < 400 bar

Pressure transmitter UNIVERSAL CA

Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids

MWF+ Application. Types Available. Average temperature sensor. Datasheet

Gas-actuated thermometer with switch contacts For sanitary applications, stainless steel version Model 74

S 100 Single-jet Water Meter Unobtrusively upmarket just what it should be

VZFA/VZOA MISURATORI DI PORTATA FUEL OIL METERS. CONTOIL VZFA/VZOA , versions for special requirements / applications

macnaught flow measurement

Pressure transmitter COMPACT ECOnomic

Wafer Check Valve Type 012 PVC-U

STUF-280W. Features: Ultrasonic Water Meter, DN15~DN40. Ultrasonic Water Meter DN50~DN600

Level Probes multicap T DC 12 TE multicap T DC 11/16/21/26 TEN/TES

Transcription:

APPLICATION The bulk water meter WESAN WP can be used for measuring the flow (cold water up to 30 C) in supply lines with high flow at low pressure loss. FEATURES 4 For horizontal and vertical installation 4 Calibratable measuring insert 4 Removable measuring insert 4 Sealed measuring insert for better accuracy 4 Flange to DIN 2501 and DIN 2533 4 Overall lengths to DIN 19625 and DIN ISO 4064 4 Hydraulic bearing relief 4 Wear-resistant plastic bearing 4 Encapsulated counter of glass/copper IP 68 4 Complete head unit with counter and sensors can be rotated by 350 for easier reading 4 Integrated measurement outputs as standard 4 Sensors for remote readout (digital) and flow measurement (analogue) can be retrofitted on site without affecting calibration

GENERAL Medium temperature range C 0... 30 Temperature safety C 0... 50 Ambient operating temperature C 0... 55 Ambient storage temperature C 0... 55 Protection class IP 68 TECHNICAL DATA Nominal flow rate (DIN ISO 4064) Q n m³/h 15 25 40 60 100 150 Permissible continuous load (HY) Q n m³/h 30 50 120 230 250 250 Maximum flow rate (short-term) Q max m³/h 90 120 200 300 350 350 Transition flow rate horizontal Q t m³/h 1 1.2 0.8 1.8 2 4 Transition flow rate vertical Q t m³/h 1.8 2 0.8 1.8 2 4 Minimum flow rate horizontal Q min m³/h 0.35 0.45 0.5 0.6 0.6 1.8 Minimum flow rate vertical Q min m³/h 0.4 0.5 0.5 0.6 0.6 1.8 Starting flow rate l/h 90 130 160 190 190 1500 Flow rate at 0.1 bar pressure loss m³/h 35 63 115 115 105 310 Nominal pressure PN bar 16 16 10 / 16 16 16 16 Nominal flow rate (DIN ISO 4064) Q n m³/h 250 400 600 1000 1500 Permissible continuous load (HY) Q n m³/h 325 600 700 1250 2000 Maximum flow rate (short-term) Q max m³/h 650 1200 1500 2800 4200 Transition flow rate horizontal Q t m³/h 6 20 50 50 80 Transition flow rate vertical Q t m³/h 6 - - - - Minimum flow rate horizontal Q min m³/h 4 12 18 30 45 Minimum flow rate vertical Q min m³/h 4 - - - - Starting flow rate l/h 2500 5000 10000 15000 20000 Flow rate at 0.1 bar pressure loss m³/h 550 800 1250 3000 6000 Nominal pressure PN bar 16 10 / 16 10 / 16 10 / 16 10 / 16 11.01.2012 2

PULSE OUTPUTS Reed switch 570* - pulse value 1 l/pulse 100 100 100 100 100 1000 Reed switch 570* - pulse value 2 l/pulse 1000 1000 1000 1000 1000 10000 Special pulse value l/pulse 25 / 50 25 / 50 25 / 50 25 / 50 25 / 50 250 / 500 IR pulse transmitter 573* l/pulse 1 1 1 1 1 10 Reed switch 570* - pulse value 1 l/pulse 1000 1000 1000 10000 10000 Reed switch 570* - pulse value 2 l/pulse 10000 10000 10000 100000 100000 Special pulse value l/pulse 250 / 500 250 / 500 250 / 500 2500 / 5000 2500 / 5000 IR pulse transmitter 573* l/pulse 10 10 10 100 100 * For more information about reed switch 570 and IR pulse transmitter 573 please have a look at the specific datasheet. DISPLAY RANGE 0.5 l... 999,999 m³ 5.0 l... 9,999,999 m³ 50 l... 99,999,999 m³ 0.5 l... 999,999 m³ 5.0 l... 9,999,999 m³ 50 l... 99,999,999 m³ APPROVAL EC D 92 / 6.132.33D 92 / 6.132.33D 02 / 6.132.42D 02 / 6.132.42D 02 / 6.132.42D 02 / 6.132.43 National - - - - - - Metrological class B H B H B B B B EC D 02 / 6.132.43 - - - - National - 6.132 / 06.24 6.132 / 06.24 6.132 / 92.07 6.132 / 92.07 Metrological class B B B B B 11.01.2012 3

DIMENSIONS Overall length L mm 200 200 200 / 225 250 250 300 Flange diameter D mm 165 185 200 220 250 285 Hole circle diameter PN 10 / PN 16 K mm - / 125 - / 145 160 / 160 - / 180 - / 210 - / 240 Number of screwholes PN 10 / PN 16 pcs - / 4 - / 4 4 / 8 - / 8 - / 8 - / 8 Screwhole diameter PN 10 / PN 16 D1 mm - / 18 - / 18 18 / 18 - / 18 - / 18 - / 22 Height H mm 75 83 89 105 115 135 Height H1 mm 123 123 154 154 154 245 Height to remove measuring insert mm 225 225 275 275 275 475 Meter width mm 155 155 200 220 250 285 Diameter Ø B mm 110 110 110 110 110 110 Weight kg 10.2 11.2 13 16 21.5 39 Overall length L mm 350 450 500 500 500 Flange diameter D mm 340 405 460 580 715 Hole circle diameter PN 10 / PN 16 K mm 295 / 295 350 / 355 400 / 410 515 / 525 620 / 650 Number of screwholes PN 10 / PN 16 pcs 8 / 12 12 / 12 12 / 12 16 / 16 20 / 20 Screwhole diameter PN 10 / PN 16 D1 mm 22 / 22 23 / 27 23 / 27 27 / 30 27 / 33 Height H mm 163 193 230 290 360 Height H1 mm 245 242 290 311 361 Height to remove measuring insert mm 475 472 520 580 660 Meter width mm 340 405 460 580 715 Diameter Ø B mm 110 110 110 110 110 Weight kg 47 75 165 190 300 11.01.2012 4

SPECIAL VERSIONS - High-pressure version up to 25/40 bar - Flange for ANSI and BS - CuZn parts in V2A - Temperature up to 90 C - Different pulse outputs - Special overall length - Electronic counter module PRESSURE LOSS GRAPH / TYPICAL ERROR GRAPH Pressure loss graph Typical error graph 11.01.2012 5

APPLICATION Meter for measuring heavily fluctuating flow rates. FEATURES 4 Replaceable measuring insert in one unit, suitable for calibration comprising: measuring insert as main meter, switch-over valve, measuring capsule as bypass meter 4 Installation: horizontal, rising pipe, downpipe, 90 tilted 4 Ideal design of housing and housing cover prevents sedimentation, stagnant water and air pockets 4 Bypass line integrated in housing cover. No risk of sedimentation or corrosion. 4 No measuring errors in the switch-over range 4 Measuring capsule as bypass meter and non-return valve easily replaced on site 4 Good long-term measuring accuracy 4 Complete head unit with counter and sensors can be rotated by 350 for easier reading 4 Main meter and bypass meter are prepared for connection of two reed switch and one opto transmitter 4 In order to secure a safe switch-over the WESAN WPV needs a minimum ingoing pressure of 0.6 bar

GENERAL Medium temperature range C 0... 30 Temperature safety C 0... 50 Ambient operating temperature C 0... 55 Ambient storage temperature C 0... 55 Nominal pressure PN bar 16 Display range 0.05 l... 999,999 m³ Approval National 6.152 / 98.14 Metrological class B Protection class IP 65 TECHNICAL DATA Nominal diameter DN mm 50 80 100 Nominal flow rate (DIN ISO 4064) Q n m³/h 15 40 60 Permissible continuous load (HY) Q n m³/h 35 120 230 Maximum flow rate (short-term) Q max m³/h 90 200 300 Transition flow rate Q t m³/h 0.0375 0.0375 0.0375 Minimum flow rate Q min m³/h 0.02 0.02 0.02 Starting flow rate l/h 15 15 15 Nominal flow rate bypass meter Q n m³/h 2.5 2.5 2.5 Switch-over flow rate rising m³/h 2.2 2.3 2.3 Switch-over flow rate falling m³/h 1 1.5 1.5 PULSE OUTPUTS Main meter - reed switch 570* l/pulse 100 / 1000 Main meter - IR pulse transmitter 573* l/pulse 1 Bypass meter - reed switch 570* l/pulse 100 / 1000 Bypass meter - pulse transmitter 571* l/pulse 0.1 * For more information about reed switch 570, pulse transmitter 571 and IR pulse transmitter 573 please have a look at the specific datasheet. 13.04.2010 2

DIMENSIONS Nominal diameter DN mm 50 80 100 Overall length (DIN 19625) L mm 270 300 360 Overall length (DIN ISO 4064) L mm - 300 350 Flange diameter D mm 165 200 220 Hole circle diameter K mm 125 160 180 Number of screwholes pcs 4 8 / 4 8 Screwhole diameter D1 mm 18 18 18 Height H mm 75 101 101 Height H1 mm 130 140 140 Height H2 mm 136 146 146 Height to remove measuring insert mm 245 280 280 Width B1 mm 85 100 110 Width B2 mm 160 180 180 Diameter Ø B mm 110 110 110 Weight of complete meter kg 17.4 25.5 29 Weight of measuring insert kg 6.3 9.3 9.3 SPECIAL VERSIONS - Special flange holes - Integrated pulse outputs for remote reading and flow rate measurement - Main meter and bypass meter with electronic counter module - Other types as bypass meter (electronic counter module with M-Bus, CORONA MCI 1 l/pulse) 13.04.2010 3

PRESSURE LOSS GRAPH / TYPICAL ERROR GRAPH Pressure loss graph Typical error graph 13.04.2010 4