Delta HE 35-XX, 55-XX

Similar documents
Instruction Sheets for ECM Variable Speed Pumps. AM55 Pages 2-3 AM99 Pages 4-7

LK Manifold Shunt VS2

real quality made in italy circulation pumps

3. Operating instructions: Minor 200

Product bulletin for: ST2 Ball valves with two-way and three-way BSPP threaded fittings

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800

4 Specification Magneta Smedegaard twin pumps

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE

MANUAL CONTROL UNIT FOR ROTATING HEAT EXCHANGER. MicroMax. Article no. F IBC control Made in Sweden

Mounting and Operating Instructions EB 5894 EN. Electric control valves with jet pump. Flanged version of valve with jet pump

MANUAL CONTROL UNIT FOR ROTATING HEAT EXCHANGERS. MicroStart. IBC control

RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & 6kW

Mechanical Operating Instructions

IBC control. MicroMax MANUAL. With adjustable boost function and threshold value. Since Set of EMC-glands as an option

ZB0050 / ZB0051 ZB0070 / ZB0071

Compact System NRGS 11-2 NRGS Original Installation Instructions English

DKG-114 MANUAL AND REMOTE START UNIT

JUMO MIDAS Pressure transmitter

Dosing Pump Operational Manual

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

SERIES 2000 GAS SAFETY SHUT OFF VALVE

RE, RED. Electronically Controlled Inverter Driven Circulation Pump. Twin Execution ENERGY EFFICIENCY OF CIRCULATING PUMPS

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

Pump Stations for Heating Circuits

Data sheet: Wilo-Stratos PICO 25/1-6

Installation and Operating Instructions Electric Vibrators HV/VFL Series

IFX-M4-03 IFX-M4-03_D_E_2017_05_REV.0

Series description: Wilo-Stratos ECO-STG

Heating Cost Allocation Valve with local acquisition of the flow temperature

720 W / 24 V On-board Battery Charger. for industrial applications. Product Data Sheet

Data sheet: Wilo-Stratos PICO 25/

ECONOMISER SERIES E2T USER MANUAL

On/Off- Solenoid to RL 94/9/EG (ATEX 95) G HP E Pamphlet

Lenntech. Calio S. Type Series Booklet. High-efficiency Circulator Pump. Tel Fax.

HPP09E Hydraulic Powerpack

3 Specification Magneta Smedegaard

Diaphragm Vacuum Pumps and Compressors

RVS-AX Instruction Manual

* _0817* Drive Technology \ Drive Automation \ System Integration \ Services. Revision. MOVIMOT MM..D with AC Motors DT/DV

Operating Instructions for Pressure Transmitter with Digital Display. Model: PDA

Solenoid Operator 0516 / 1216

WELDING INVERTER. PEGAS 160 E Smart PEGAS 200 E Smart OPERATING MANUAL. ALFA IN a.s. PEGAS E Smart Manual EN 04

DEVICE STATE/BYPASSED FAILURE OVERLOAD

Mounting and Operating Instructions EB 5868/5869 EN

Operating Instructions Control 330 Conductivity meter

Operating Instruction for Flowmonitor. Model: DF-WM

MVSS. Technical features

Safety Limit Switch

MAGNA3 D F 280 1x230V PN16

Documentation. RM-BV4 Micro DP. Filter control

LK Manifold Shunt VS 2-2,5

Mounting and Operating Instructions EB 3913 EN. Electropneumatic Converters i/p Converter Type

4/3 directional control valve, pilot operated, with electric position feedback and integrated electronics (OBE)

Solenoid Operator 0513 / 1213

Operating Instructions for Plastic Flow Meter. Model: KSK

SKF Electro-pneumatic Barrel Pump EPB-Pump-ECO (Original operating and maintenance instructions according to EU Directive 2006/42/EC)

Technical features Certifications

SPEEDRIVE INSTRUCTIONS MANUAL

Diaphragm Vacuum Pumps and Compressors

3/2 and 4/2 directional seat valves with solenoid actuation

Holtumsweg 13, D Weeze, Tel /9134-0, Fax /1444

Heavy Duty Series (HDS) Installation and user guide

MAGNA3 D x230V PN10

TPHK Series Immersible Pump

Type 0283, Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

LJASeries. Limit Switches with Positive Opening Mechanism

3000W HF/PFC Battery Charger

High efficiency pumps

Instruction manual. CSV 402 caravan power supply. Table of contents

Ex m Solenoid Operator Type 0519

MAGNA F 250 1x230V PN6/10

MAGNA F 340 1x230V PN6/10

JUMO heattherm Type Protection temperature limiter, as a panel-mounting thermostat Compensated for ambient temperature

To order, quote model number from table overleaf, e. g for a DN 25 valve.

MVSI. Technical features

Operating Instructions for Paddle Bellows Flow Monitor. Model: FPS-P...

EDI K_Instructions.qxd 28/07/ :34 Page 1 ORDER CODE: EDI K MODEL IRT537. Infrared Thermometer OPERATING MANUAL CLASS 2 LASER

Start-up instructions

Diaphragm Vacuum Pump

PANcharge1k Battery Charger User's Manual

Type 3761 Pneumatic or Electropneumatic Positioner for Rotary Actuators. Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

TECHNICAL SPECIFICATION

ULTRASONIC FLOW SENSOR QALCOSONIC FLOW 2

MTF. Technical features

THREE PHASE AND SINGLE PHASE ASYNCHRONOUS ELECTRIC MOTORS OPERATION AND MAINTENANCE BOOKLET Rev

Operating Instructions for Polysulfone Paddle Monitor. Model: PPS-..

EB EN. Type 3372 Electropneumatic Actuator. Translation of original instructions

86740/ /2-way piston valves

TECHNICAL SPECIFICATION

MAGNA x230V PN10

NV Direct Coupled Globe Valve Actuator

Company name: Created by: Phone:

AF40... AF96 3-pole contactors Technical data

TLR2 RESOL TLR2 * * Mounting Connection Handling Fault localization. Manual

MAGNA x230V PN10

Modulating control valves with magnetic actuators, PN 16

On/Off- Solenoid to RL 94/9/EG (ATEX 95) G HP E

HERZ Electronic room thermostat analog and digital

TPAK Series COOLANT PUMP

Transcription:

Installation and Operating Instructions Delta HE 35-XX, 55-XX 10.2009

Table of contents Table of contents EC Conformity Declaration Technical Data Delta HE 35 Technical Data Delta HE 55 Mounting Instructions Installation and Wiring System Filling and Aeration Troubleshooting Operating Panel Pump Settings Night Setback page 3 4 5 6 7 8 9 10 12 13 2 15

EC Conformity Declaration We herewith declare that the products of the Delta HE series comply with the following EC Directives: Electromagnetic Compatibility Directive 2004/108/EC Low Voltage Directive 2006/95/EC Applied Harmonised Standards: EN 61000-3-2 : 2006 EN 61000-3-3 : 1995 + A1 : 2001 + A2 : 2005 EN 55014-1 : 2006 EN 55014-2: 1997 A1 : 2001 Bad Oeynhausen, 28.10.2009 14 3

Technical Data Delta HE 35-XX Night setback Press the key to activate the night setback. If the display comes on, the night setback is activated and the pump automatically switches from normal operation to night set-back. The change between the two modes depends on the advance flow temperature. The pump automatically changes to night setback if the advance flow temperature falls by more than 10 C to 15 C within one hour. The display indicates -C. As soon as the advance flow temperature increases by 3 C the system changes back to normal operation. Permanent night setback For setting the night setback as permanent mode, press the key again for 5 seconds. The display indicates -C. The pump remains in night setback mode until the push-button is pressed again. Max. delivery height: Max. flow rate: Power consumption P1 (W) Supply voltage Degree of protection Thermal class Ambient temperature Media temperature Max. system pressure Media 4,0 m 2600 l/h 3-23 1x230V 50Hz IP 42 F 0 C to 40 C +5 to 95 C 10 bar Heating water according to VDI 2035 Water/glycol mix 1:1 4 13

Pump Settings Technical Data Delta HE 55-XX Pump Settings Proportional pressure control During operation the pump is running according to the proportional pressure curve set. The differential pressure is controlled through the pump depending on the delivery current. The proportional pressure characteristics are named PD1 to PD4 in the corresponding Q/H diagrams. Constant speed control The constant speed control characteristics are named I to III in the Q/H diagrams. When selecting constant speed control the pump speed does not change over the entire cycle. Automatic night setback Requirements for automatic night setback Note Pumps installed in gas water heaters which only contain a small amount of water must not be set to night setback. If the heating system does not deliver sufficient water to the radiators, please check whether the automatic night setback is activated. If necessary, switch off the night setback. The following requirements must be fulfilled to ensure proper working of the night setback: 1. The pump must be installed in the advance flow. 2. The heating system must be equipped with an automatic advance flow temperature control. 12 Max. delivery height: Max. flow rate: Power consumption P1 (W) Supply voltage Degree of protection Thermal class Ambient temperature Media temperature Max. system pressure Media 6,0 m 3200 l/h 3-38 1x230V 50Hz IP 42 F 0 C to 40 C +5 to 95 C 10 bar Heating water according to VDI 2035 Water/glycol mix 1:1 5

Mounting Instructions Fig. 1 Display The display comes on as soon as the pump is connected to the voltage supply. It indicates the actual power consumption during operation. Faults are indicated as errors: E1, E2 or E3 If the pump operates in night setback, the decrease is indicated in -C. Fig. 2a Fig. 2b Fig. 2c Fig. 2d Push-button for pump curve selection The pump setting is changed by pressing the push-button. You run through all possible settings by pressing the push-button seven times. 6 Fig. 3 Display Explanation I Constant speed level I II Constant speed level II III Constant speed level III PD1 Bottom proportional pressure curve PD2 Second proportional pressure curve PD3 Third proportional pressure curve PD4 Top proportional pressure curve Push-button for night setback The automatic night setback is activated by pressing this push-button. It is indicated in the display. The night setback is continuously and immediately activated by pressing the push-button again for 5 sec. The setback is indicated in C in the display. The night setback is deactivated by pressing the push-button again. 11

Pump Settings and Delivery Rate Operating panel Push-button for pump curve selection III II I PD 4 PD 3 PD 2 PD 1 Installation and Wiring Mounting Instructions The system must only be wired by experts and according to local regulations. Warning! Risk of personal injury! The existing Health and Safety Regulations must be observed! Warning! Risk of electric shock! Any hazard caused by electric energy must be avoided. General and local Regulations and Directives (e.g. IEC, etc.) must be observed. Push-button for night setback Power consumption Installation Ensure installation without any strain and mount the pump motor in a horizontal position (arrow on the pump housing indicates the direction of flow) (Fig. 1). Pump motor and electronic housing must not be insulated! If you need to change the mounting position, the motor housing must be rotated as follows: (Fig. 2a to 2d). Loosen the hexagon socket screws Rotate the motor housing Tighten the hexagon socket screws Wiring The pump is equipped with a preinstalled connection cable. Current and voltage must comply with the indications on the nameplate. If the pump is to be used in systems with temperatures exceeding 90 C ensure the use of corresponding connection cables. 10 7

Mounting Instructions System Filling and Aeration Troubleshooting 1. Pump does not start when power is supplied. Check mains fuse Check voltage applied to the pump 2. Noise generated in the system. Aerate the system Check the pump settings 3. Noisy pump Aerate pump (see page 8) Increase the inlet pressure and check the gas volume in the expansion vessel. 4. Building does not heat up Increase the set value (see page 11) Switch off night setback (see page 11) Please contact a specialist if you cannot eliminate the fault. The system must be in upright position for filling and aeration. Set the electronics to III and run the system for at least 10 minutes before you aerate the pump. After aeration the pump can be reset to any control mode. 8 9