Circa Ambient Interior Luminaire

Similar documents
INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION

Installation Instructions Shaper 1800 aircraft cable installation

MEDIA LED. Pendant Standard Mount Installation ou de montage WARNING:

HBDBM High Bay Series

LED IMPORTANT SAFETY INSTRUCTIONS

LED IMPORTANT SAFETY INSTRUCTIONS

LED W IMPORTANT: not provide. contact the. fire. LED only. entrap heat. applications. carry high GENERAL: Compare. material.

High Bay Luminaire Series

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION.

SAVE THESE INSTRUCTIONS

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION.

LED IMPORTANT SAFETY INSTRUCTIONS

General Installation Instructions LED

INSTRUCTION SHEET. Installation Instructions for Mercmaster LED Luminaire. Applications. Agency Ratings. Product Safety

Installation Instruction

Installation Guide. WARNINGS Read all instructions and warnings before attempting installation


HP-2 / HP-6 Direct Installation Instructions Overview

Assembly instruction. Pendant Light Toccata GENERAL REMARKS ON SAFETY: Technical data: BOM

General Installation Instructions LED

MOUNTING SYSTEMS SPECIFICATIONS

MaxLite LED Linear HighBay Fixtures

Utility Distribution Systems Installation, Operation, and Maintenance Manual

Installation Instructions

Prismpack V, Prismalume V, Large Prismpack, Large Prismalume

Installation Instructions BLTR and 2BLTR Relight Assembly

Installation Instructions for Appleton Mercmaster LED Luminaire

Elle Surface Mounting Instructions

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION

AIR by 3M Luminaire Installation Guide 3 ft. Pendant. Standard and Specialty Finishes A003-XX-3K-XX-XX A003-XX-4K-XX-XX. Installation Guide

Luminaire Support Location Cable Mounting Kit. Non-Power Feed

Elle Surface Mounting Instructions

Installation Instruction ALG Series LED Area Light Version: 3.1

NOVO LIGHTED MIRROR. Installation Instructions

Plasma Dual Swing-Out (PDS Series) Wall Mount

Customer service: or Upper mounting ring. Canopy

HEATED HAND GRIP KIT

NOTE: The orientation of the mounting brackets are critical. (See Figure 4)

Zynn Lines - Pendant. AIP in DESCRIPTION FEATURES & BENEFITS SPECIFICATIONS PROJECT DETAILS JOB NAME: TYPE: NOTES:

Dispenser Pan Sensors & Containment Sump Sensors

Installation Instructions Electric Heaters 5 20 kw

Installation Manual Stand-Alone Dispenser Pan Sensor

COMPACT GLYCOL FEED SYSTEMS OPERATION & MAINTENANCE MANUAL

TORi INSTRUCTION SHEET. Minimalist Linear Fixture T5/T5HO. CSS - Cable Suspended. 1. Cut cables to desired length - take care not to fray cable ends.

Specialty Finishes. AIR by 3M Installation Guide 7 ft. Pendant, Specialty Finishes. Installation Guide

Installation Instructions Electric Heaters 5 20 kw

EMERY SKY SUSPENDED LED LUMINAIRE

INSTALLATION AND MAINTENANCE MANUAL FORM #PM-126 REV A 12/09

Zynn Ring. AIP in DESCRIPTION FEATURES & BENEFITS SPECIFICATIONS PROJECT DETAILS JOB NAME: TYPE: NOTES:

Installation Instructions

One Circuit Trac System TRAC SECTION, JOINERS & FEEDS T Series

LED Decorative Highbay

HBDB High Bay Fixture with Occupancy Sensor

PERMA ROLL 75. installation instructions Automatic Roll-up Door. note:

INSTALLATION INSTRUCTION W Track Suspension system

Test Cabinet (Inspection Box) Instructions. for Testing Accessories on Manually and Electrically Operated EntelliGuard G Low Voltage Circuit Breakers

ibusway for Data Center

ILLUMINA BS100 INSTALLATION INSTRUCTIONS FLUORESCENT VAPOR TIGHT

Raritan PX. Power Cord Installation Guide. Safety Guidelines. Safety Instructions

Operating Instructions

ELECTRICAL. 60 Minutes

An average of one worker is electrocuted on the job every day There are four main types of electrical injuries:

Albeo TM LED Luminaire Heavy Industrial High Bay Lighting (ABR1-Series)

Jet Fans. Instruction Manual READ AND SAVE THESE INSTRUCTIONS WARRANTY

Utility Distribution System

SAVE THESE INSTRUCTIONS

INSTALLATION INSTRUCTIONS LIGHTPLANE 3.5. LP3.5 Suspended LED. A nd Avenue, Unit 1. CA P E W alwusa.

SAVE THESE INSTRUCTIONS!!

TRAC-LITES One Circuit Trac System TRAC SECTIONS & SYSTEM COMPONENTS R Series

USER GUIDE LED LIGHTED MIRROR W/BUILT-IN MAGNIFIER. Model: , , ,

AIR CLEANERS. Model MX 6000 OWNER S MANUAL CAUTION. Read complete instructions before operating. Please file for future reference.

V-Twin Forward Control Installation Instructions

I. Pendant Mount Installation

IMPORTANT SAFETY INSTRUCTIONS

One Circuit Trac System TRAC SECTION, JOINERS & FEEDS T Series

Air Curtain. Installation, Operating and Maintenance Instructions

SUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS - ELECTRICAL

MaxLite StaxMax LED Flood Lights

Arnberg Industries & It s Partners are not responsible for any damage or injury caused by correct or incorrect installation of this transfer switch.

Illustrations on the manual are for installation purposes only. It may not be identical to the fixture purchased.

Dispenser Pan Sensors & Containment Sump Sensors

COOPER POWER. SERIES CMU Medium voltage power fuse installation instructions. Fusing Equipment MN132032EN

w w w. h d o n l i n e s h o p. d e LAYBACK LICENSE PLATE AND TURN SIGNAL RELOCATION KIT INSTALLATION GENERAL -J03892 REV Kit Number

SAVE THESE INSTRUCTIONS

Electric Pilot System

TAG-DR Series. Indoor or Outdoor LED Driver Box - TAG LED Flood Solutions. Specifications. Overall Dimensions For Reference Only TAG-DR

USER S GUIDE HIGH INTENSITY ULTRASONIC PROCESSOR

JAZZ J400C (COLOR), J400AS (AUTO SYNC)

Photometric Drawing for (1) T5L-1T528 VOLTAGE MOUNT OPTIONS v v

LIGHTPLANE 1 RECESSED - LP1R

Jazz/FX Series Spa Light Jazz Series 120 Volt only FX Series 120 Volt or 12Volt. Owners Manual

INSTALLATION INSTRUCTIONS SUPERPLANE 2.5. Suspended. A nd Avenue, Unit 1 Oakland, CA P E W alwusa.

Electrical Safety. Electrical Safety Webinar. Electrical. Printing Industries Alliance Printing Industries Alliance 1

II Bagger/III Bagger Adjustable FLH/FLT Arms Installation Instructions

FINA SUSPENDED INSTALLATION INSTRUCTIONS

Installation and Operation

INSTALLATION INSTRUCTIONS For Light*Waves Flex II Kit with 300-Watt remote transformer

Transcription:

IMPORTANT SAFETY INSTRUCTIONS 1. Read carefully before installing fixture. Retain for future reference. To prevent electrical shock, turn off electricity at fuse box before proceeding. 2. Failure to follow instructions may result in serious injury or death. 3. Upon receipt the fixture, thoroughly inspect for any freight damage which should be brought to the attention of the delivery carrier. Compare the catalog description listed on the package slip with the fixture label on the housing to assure you have received material. 4. This fixture must be wired in accordance with the international electrical code and applicable local codes and ordinances. Proper grounding is required to insure personal safety. Carefully observe the correct grounding procedure under installation section. 5. DECO luminaires may be damaged if connected to conduit systems containing water - Article 300-5G of National Electric Code requires that Conduits or raceways through which moisture may contact energized live parts shall be sealed or plugged at either or both ends. *Deco Digital assumes no responsibility for claims arising out of improper or careless handling or installation of this product. 1. Prepare ceiling -Install an Octagonal junction box (by others) in the ceiling, ensuring that the junction box can support 50 lbs minimum. - Feed power into the junction box, following local and national electrical code standards. - Ensure that circuit is not energized during installation. 1

2. Install driver box top section onto junction box. - Feed wires through the central opening of the box. - Fasten driver box top section to the junction box using the two 8-32 round head screws provided with the junction box. 3. Make electrical connections to driver. Follow local and national building codes. 2

4. Install driver box cover onto driver box top section using three 6-32 oval head screws provided. Twist cover until holes align. 5. Install aircraft cable. - There are three aircraft cables provided. - Cut aircraft cables to roughly the desired length, leaving extra length of approximately 6 inches. 3

- A ring accessory is provided. This ring allows the three cables to hang vertically for most of the total height. - If desired, feed aircraft cables through the ring accessory form the smooth side of the ring. - Feed ends of cables into the cable grippers in the driver box cover to the desired length. If pushed in too far, cables can be pulled out by first depressing on locking cylinder, then pulling of the cable while cylinder is depressed. DETAIL A DETAIL B 4

6. Install luminaire. - Aircraft cables have cable terminals that thread onto threads on the top of the luminaire. - Thread the terminals onto the threads for all three cables. - Adjust height of ring accessory (if installed) to desired height. - Adjust height of cables until luminaire is level. A DETAIL A 7. Connect power to luminaire. - The power cord has two parts, one on the driver box, the other on the top of the luminaire. - Adjust the length of the driver box cord as necessary. - Connect the two sections of cord. The cord connectors push in, then twist to lock. 8. Circuit can now be energized. 5