Insulated Control Damper. 12 x 7 (305 x 178) 8 x 7 (203 x 178)

Similar documents
Thermal Isolation Break. Frame Type Channel Quick Connect Single or Reverse Flange Blade Action Parallel Opposed Parallel Opposed Parallel Opposed

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x in. W x 120 in. H (3658mm x 3048mm) 5 in.

Thermal Isolation. Break

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x 305) 5 in. (127mm) Parallel

Baked Enamel, Epoxy, Hi Pro Polyester, Industrial Epoxy, Kynar/Hylar (70%) Permatector. Single or Reverse Flange 8 x 6 (203 x 178)

Model VCD-18. Ratings. Blade Operation. Size Limitations. Features & Options

Model VCD-40. Extruded Airfoil Blade Control Damper Narrowline Frame Construction. Application. Ratings. Flange Options.

Model VCD-43 Extruded Airfoil Blade Control Damper

Model VCD-34. Low Leakage Insulated Airfoil CONTROL DAMPER. Ratings (See page 3 for specific limitations) Flange Options.

Model SEVCD-33. Low Leakage Airfoil Control Damper. Application and Design. Ratings (See page 3 for specific limitations) Blade Operation

AMD-33. Air Measuring Station with VCD-33 Control Damper. Application and Design. Features & Control Options

AMD-33 Air Measuring Station with VCD-33 Control Damper

AMD-42-TD. Thermal Dispersion Air Measuring Station with VCD-42 Control Damper. Application and Design. Ratings. Features and Control Options

FBV-43. Vertical Face & Bypass Control Damper Ultra Low Leakage Aluminum Frame Construction. Application and Design. Size Limitations.

Model VCD-20. Control Damper. Application. 3V Blade. Ratings. Flange Options. Size Limitations. Blade Operation. Features and Options

VCD-23. Flange Options. Size Limitations

AMD-42V Air Measuring Station with VCD-42V Control Damper

AMD-42 Air Measuring Station with VCD-42 Control Damper

VCD-43V. Vertical Airfoil Blade Control Damper. Application and Design. Ratings. Size Limitations. Features and Options: Pressure:

AMD-23-TD. Thermal Dispersion Air Measuring Station with VCD-23 Control Damper. Application. Ratings. Features and Options

Model VCD-33. Low Leakage Airfoil CONTROL DAMPER. Flange Options. Blade Operation. Size Limitations

Model VCD-20 3V CONTROL DAMPER

VCD-23 Low Leakage CONTROL DAMPER

VCD-23. Low Leakage CONTROL DAMPER

HCD-135. Industrial Control Damper. Application and Design. Ratings (see page 2 and 3 for specific limitations) Standard Construction.

HCD-230 Industrial Control Damper

Model VCD-20V. 3V Vertical Control Damper. Application and Design. Ratings (See page 4 for specific limitations) Flange Options.

Model DFD-230 Multi-Blade Fire Damper Steel 3V Blades UL555 3 Hour Fire Resistance Rating

Model SMD-302M. Modulating Smoke Damper. Application. Steel Airfoil Blades UL 555S Leakage Class II. Ratings. Size Limitations.

Model CFSD-211. Corridor Ceiling FIRE SMOKE DAMPER Steel 3V Blades UL 555S Leakage Class I

SMD-201M. Application. Modulating Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

Model FSD-212. Combination FIRE SMOKE DAMPERS

Model FSD-211. Application. Combination Fire Smoke Damper Steel 3V Blades UL 555S Leakage Class I UL /2 Hour Fire Resistance Rating.

Model FSD-331. Combination Fire Smoke Dampers. Application. Ratings. Features

Model SMD-301. Smoke Damper Steel Airfoil Blades UL 555S Leakage Class I. Application. Ratings. Size Limitations. Features

Model SSFSD-211. Combination Fire Smoke Damper 304 Stainless Steel 3V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

TED50XT EXTREME TEMPERATURE THERMALLY EFFICIENT, INSULATED BLADE DAMPER

SMD-201. Application. Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

Model FSD-331 Combination Fire Smoke Dampers

Model FSD-211. Combination FIRE SMOKE DAMPERS Steel 3-V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

HVAC Control & Balancing Dampers

Air Measuring Products AMD AMS IAQ

Air Measuring Products. AMS Thermal Dispersion Pressure Differential

WD-300 Series. Backdraft Damper Vertical Mount - Horizontal Airflow. Application and Design. Ratings. Frame Styles. Size Limitations.

WD-200 Series. Model WD-220 Flange Opposite Motor. Model WD-210 Flange on Motor Side. Model WD-200 No Flange. Motorized Backdraft Damper.

HVAC Control & Balancing Dampers

SP Standard Profile. In Duct or Flanged to Duct Install Types OPPOSED ACTION PARALLEL ACTION. Extended Rear Flange Install Type

5995 Greenwood Plaza Blvd. Suite 100 Greenwood Village, CO (fax)

ID-141x 12-Gauge Hat Channel Industrial Damper

AMCA MEMBER. American Warming and Ventilating. A Mestek Company. Quality Air Control Dampers

Positive Seal Damper Blades with Vinyl Gaskets 2.5" SERIES 3000 SIDE MOUNT - NO FLANGE ORDERING METHOD FOR BACKDRAFT & MOTORIZED BACKDRAFT DAMPERS

Control Dampers and Fire Dampers. Volume 1 - March Insulated Control Dampers. Non-Insulated Control Dampers. Framing. Accessories.

LOW LEAKAGE VOLUME CONTROL DAMPER

ARROW INDUSTRIAL PRODUCTS

HVAC Control Damper Models VCD and MBD. Selection Construction Performance

Control Dampers. Leakage Performance. Model FDNB (Opposed Blade) FDQB (Parallel Blade) Galvanized 3V Blade Control Dampers

Series HCD Airfoil Control Damper

Motorized Fire Dampers

Blast Protection Damper

CONTROL DAMPERS. Model Model 1370CB. Model 1380CB. Model 1390CB B7

Blast Protection Damper

Model DFD-350. Dynamic Rated Fire Damper 3 Hour Fire Resistance Rating. Application. Ratings. Optional Features

SafidDampers SPK Standard Construction SPK Description SPK ( Flange Type )

DAMPERS FOR COMMERCIAL & INDUSTRIAL APPLICATIONS IN HEATING, VENTILATING & AIR CONDITIONING

Model DFD-150. Dynamic Rated Fire Damper 11/2 Hour Fire Resistance Rating. Application. Ratings. Optional Features

ARROW UNITED INDUSTRIES

Model DFD-150. Dynamic Rated Fire Damper 11/2 Hour Fire Resistance Rating. Application. Ratings. Optional Features

Introduction to Johnson Controls Dampers

SafidDampers SPK Description. Standard Construction SPK ( Flange Type )

AD-1250 Airflow Measuring Station

BD-1600 Balancing/Zone Control Damper

SECTION CONTROL DAMPERS

SD-1250 and SD-1600 Series Smoke Dampers

CONTROL DAMPERS. Models 1810 & Model Model Model 1370

STATIONARY LOUVERS STATIONARY LOUVERS STATIONARY LOUVERS

PC-125x Counter-Balanced Backdraft Damper


Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

FSD60, FSD60LP CoMBINAtIoN FIRe AND SMoKe DAMPeR

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

VOLUME CONTROL DAMPER

Life Safety Dampers. Fire Combination Fire Smoke Smoke Ceiling Radiation

DAMPERS WE CONTROL AIR

CONTROL DAMPERS GENERAL PRODUCT OVERVIEW MODELS 1010 & 1020 LOW LEAKAGE CONTROL DAMPER VEE GROOVE BLADE MODELS 1012 & 1022 STANDARD CONTROL DAMPER

SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS

RM-1200 Slim Round Control Damper

SECTION AXIAL HVAC FANS

VOLU-probe. Pitot Airflow Traverse Probes. amca. Accurate airflow measurement for demanding applications. CERTIFIED RATInGS

B. Fabricate in accordance with ASHRAE handbooks and SMACNA duct manuals. A. Submit in accordance with Division-1 and Section

A. Product Data: For each type of product. TLC ENGINEERING FOR ARCHITECTURE - PROJECT NO AIR DUCT ACCESSORIES

UNIVERSITY OF NORTH FLORIDA Arena HVAC Replacement SECTION MODULAR INDOOR CENTRAL-STATION AIR-HANDLING UNITS

FOR USE IN SOLUTION AIR HANDLING UNITS

VD-1600 Series Volume Control Dampers

AFL-501. Aluminum FEMA 361 Louver Chevron Blade Application and Design

FSD36, FSD36LP COMBINATION FIRE AND SMOKE DAMPER 1 1 /2 HOUR UL555 RATED, UL555S LEAKAGE CLASS 2

SECTION FLOW INSTRUMENTS

Model FD-350. Static Rated Fire Dampers 3 Hour Fire Resistance Rating. Application. Ratings. Construction Standard Optional.

Fusible Link (replaceable) Horizontal Mount

AFG501 ALUMINUM FEMA 361 LOUVER LOUVER TYPE RECOMMENDED SPECIFICATION

Innovative Damper Products EXPERIENCE TRUE EXCELLENCE IN SERVICE, QUALITY, AND MAINTENANCE-FREE PERFORMANCE.

Transcription:

R Application and Design The is a low leakage thermally insulated damper with extruded airfoil blades. features thermally broken blade to eliminate the transfer of heat or cold penetration and reduced condensation. Its also IECC (International Energy Conservation Code) compliant with a leakage rating of 3 cfm/ft 2 @ 1 in. wg (55 cmh/m 2 @.25 kpa) or less. Ratings : Up to 8.0 in. wg (2 kpa) pressure differential : 2500 to 4000 fpm (12.7 m/s - 20.3 m/s) Leakage: 3 cfm/ft 2 @ 1 in. wg at -40 F (54.8 cmh/m 2 @.25 kpa at -40 C) 6 cfm/ft 2 @ 4 in. wg at -40 F (110 cmh/m 2 @ 1 kpa at -40 C) Temperature: -70 F to 200 F (-56 C to 93 C) Thermally Broken Blade Insulated Control Damper Standard Construction Optional Construction Frame Material Aluminum - Frame Material.125 in. (3.2mm) - Thickness Frame Type 5 in. x 1 in. (127mm x 25mm) Hat Channel Single Flange Reverse Flange or Quick Connect Blade Action Opposed Parallel Blade Material Extruded Aluminum - Blade Type Thermally Broken Airfoil - Linkage Plated Steel Out of 304SS Airstream Axle Bearings Dual Bearing With Acetal - Inner Sleeve, Flanged Outer Bearing Axle Material Plated Steel 304SS Blade Seals Silicone - Jamb Seals 304SS Silicone Greenheck Fan Corporation certifies that the model shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Programs. The AMCA Certified Ratings Seal applies to air performance ratings only. Size Limitations in. (mm) Frame Type W x H Channel Quick Connect Single or Reverse Flange Blade Action Parallel Opposed Parallel Opposed Parallel Opposed Minimum Sizes Maximum Sizes Internal Mount External Mount Single Section Multi- Section 12 x 7 (305 x 178) 8 x 7 (203 x 178) 12 x 12 (305 x 305) 8 x 12 (203 x 305) 144 in. W x 148 in. H (3658mm x 3759mm) 12 x 6 (305 x 152) 8 x 6 (203 x 152) 12 x 10 (305 x 254) 8 x 10 (203 x 254) 48 in. W x 74 in. H (1219mm x 1880mm) 96 in. W x 148 in. H (2438mm x 3759mm) 12 x 7 (305 x 178) 8 x 7 (203 x 178) 12 x 12 (305 x 305) 8 x 12 (203 x 305 144 in. W x 148 in. H (3658mm x 3759mm) 5 in. (127mm) Parallel 5 in. (127mm) Opposed Installation instructions available at www.greeenheck.com Thermal Isolation Break Blade Thermal Isolation Break

Frame Type Options Channel Frame * Width and height is based on outside dimension. W & H dimensions furnished approximately 1/4 in. (6mm) undersize. Opening Height Opening Width Reverse Flange * Width and height is based on outside dimension. W & H dimensions furnished approximately 1/4 in. (6mm) undersize. Single Flange * Width and height is based on outside dimension. W & H dimensions furnished approximately 1/4 in. (6mm) undersize.

Frame Type Options Quick Connect 1 3/8 in. Ductmate, TDC or TDF Cleat Quick Connect Frame Duct 1 3/8 in. Note: When ordering the Quick Connect Frame, size is based on duct size (or inside dimension of the damper frame). Quick Connect frame is actual size. There are applications that require mounting an into a plenum wall. This illustration depicts how to mount an into a plenum wall.

R Data This pressure drop testing was conducted in accordance with AMCA Standard 500-D using the three configurations shown. All data has been corrected to represent standard air at a density of.075 lb/ft 3 (1.201 kg/m 3 ). Actual pressure drop found in any HVAC system is a combination of many factors. This pressure drop information along with an analysis of other system influences should be used to estimate actual pressure losses for a damper installed in a given HVAC system. AMCA Test Figures Figure 5.3 Illustrates a fully ducted damper. This configuration has the lowest pressure drop of the three test configurations because entrance and exit losses are minimized by straight duct runs upstream and downstream of the damper. Figure 5.2 Illustrates a ducted damper exhausting air into an open area. This configuration has a lower pressure drop than Figure 5.5 because entrance losses are minimized by a straight duct run upstream of the damper. Figure 5.5 Illustrates a plenum mounted damper. This configuration has the highest pressure drop because of extremely high entrance and exit losses due to the sudden changes of area in the system. 6D D 4 (W) (H) 3.14 Greenheck Fan Corporation certifies that the model shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Programs. The AMCA Certified Ratings Seal applies to air performance ratings only.

AMCA Figure 5.2 12 x 12 (305mm x 305mm) Figure 5.2 24 x 24 (610mm x 610mm) 36 x 36 (914mm x 914mm) 12 x 48 (305mm x 1219mm) 48 x 12 (1219mm x 305mm) 500.03 500.02 500.03 1000.11 1000.08 1000.05 1000.06 1000.14 1500.25 1500.19 1500.11 1500.14 1500.32 2000.45 2000.34 2000.21 2000.25 2000.57 2500.71 2500.53 2500.33 2500.40 2500.89 3000 1.03 3000.77 3000.47 3000.57 3000 1.29 3500 1.40 3500 1.05 3500.64 3500.78 3500 1.76 4000 1.83 4000 1.37 4000.84 4000 1.02 4000 2.30 6D Figure 5.3 12 x 12 (305mm x 305mm) 24 Figure x 24 (610mm 5.3 x 610mm) 36 x 36 (914mm x 914mm) 12 x 48 (305mm x 1219mm) 48 x 12 (1219mm x 305mm) 1000.04 1000.03 1000.02 1000.02 1000.06 1500.09 1500.08 1500.04 1500.06 1500.14 2000.17 2000.14 2000.08 2000.10 2000.25 2500.26 2500.22 2500.12 2500.17 2500.40 3000.38 3000.32 3000.18 3000.24 3000.58 3500.52 3500.43 3500.24 3500.33 3500.79 4000.67 4000.57 4000.32 4000.43 4000 1.03 Figure 5.5 12 x 12 (305mm x 305mm) 24 x 24 (610mm x 610mm) 36 x 36 (914mm x 914mm) 12 x 48 (305mm x 1219mm) 48 x 12 (1219mm x 305mm) 500.05 500.05 500.03 500.04 500.05 1000.23 1000.21 1000.14 1000.18 1000.22 1500.52 1500.47 1500.33 1500.42 1500.51 2000.93 2000.84 2000.58 2000.74 2000.90 2500 1.44 2500 1.32 2500.91 2500 1.16 2500 1.41 3000 2.08 3000 1.90 3000 1.31 3000 1.68 3000 2.04 3500 2.83 3500 2.59 3500 1.79 3500 2.28 3500 2.78 4000 3.70 4000 3.39 4000 2.34 4000 2.98 4000 3.70

Static Difference (inches wg) Leakage & Specifications Leakage Data Leakage testing was conducted in accordance with AMCA Standard 500-D and is expressed as CFM/sq. ft. of damper face area. All data has been corrected to represent standard air at a density of.075 lb/ft 3 (1.2 kg/m 3 ). Leakage 24 X 24 36 X 36 12 X 12 48 X 12 12 X 48 Specifications Control Dampers meeting the following specifications shall be furnished and installed where shown on plans and/or as described in schedules. Dampers shall consist of:.125 (3.2mm) aluminum channel frame; aluminum airfoil blade internally insulated polyurethane foam and thermally broken. Blades shall be completely symmetrical relative to their axle pivot point, presenting identical resistance to airflow in either direction or pressure on either side of the damper. Axle will be 1 2 in. diameter plated steel; bearings are dual bearing with acetal inner sleeve, flanged outer bearing resulting in no metal-tometal or metal-to-plastic contact. Blade seal to be silicone rubber, jamb seal to be 304SS, and external (out of the airstream) blade-toblade linkage. Dampers manufacturer s printed application and performance data including pressure, velocity, leakage, and temperature limitations shall be submitted for approval showing damper suitable for pressures to 8 in. wg (2 kpa), velocities to 4000 fpm (20.3 m/s), standard air leakage less than 6 cfm/sq. ft. @ 4 in. wg (110 cmh/m 2 @ 1 kpa) and temperatures to 200 F (93 C). Damper air performance data shall be developed in accordance with the latest edition of AMCA Standard 500-D. Basis of design is. Copyright 2012 Greenheck Fan Corporation Rev. 7 January 2012