Valves, controls + systems Valves and controls for solar installations Regusol-180

Similar documents
Valves, controls + systems Boiler connection system Regumat-130 DN 25

Valves, controls + systems Stations for the connection heat generator/heating circuit

Double regulating and commissionig valves Hydrocontrol F cast iron, PN 16 Hydrocontrol FR bronze, PN 16 Hydrocontrol FS nodular cast iron, PN 25

Hydrocontrol VFC cast iron, PN 16 Hydrocontrol VFR bronze, PN 16 Hydrocontrol VFN nodular cast iron, PN 25 Double regulating and commissioning valves

KS Pump Stations. Engineering Submittal Sheet. Installation Sets for Collectors

Cocon QTZ Pressure independent control valve

Solar Thermal. Grant Solar Pump Station Installation & Servicing Instructions

AV 23 Balancing valves SETTER Inline

Multiflex Fittings. Technical information

Installation instruction

Valves, controllers + systems Double regulating and commissioning valves Hydrocontrol F cast iron, PN 16

Valves, controls + systems

Valves, controls + systems Cast iron double regulating/ commissioning valves PN 16 Hydrocontrol G

Gas and air filter. GF/1: Rp 1/2 - Rp 2 GF/3: DN 40 GF/4: DN 50 - DN 100 GF: DN DN 200

Pump Stations for Heating Circuits

Preassembled manifolds with flow meter, series CPRFL

CALEFFI. Solar pump stations 01166/14 NA. 278 and 279 series 01264/16 NA

Mikrotherm F. Manual Radiator Valves With presetting

Product range Solex Technical data and dimensioning. 5 Years

COMPONENTS FOR SOLAR THERMAL SYSTEMS

CIRCO5SolarCirculationUnit

MVD, MV, MKV, MKL, 2161C, MXV Series

COMPONENTS FOR SOLAR THERMAL SYSTEMS

VIESMANN. Installation instructions VITOSOL-F. for contractors

AVQMT. AVQT controller can be combined with AVT or STM thermostatic actuators.

Dynamic Valve Type RA-DV Pressure Independent Radiator Valve

SOLAR THERMAL EQUIPMENT

SOLAR AEROLINE. fast simple reliable. The perfect connection technology for solar hot water

Installation and Operation Instructions HeatBloC K31 - DN 25

INSTALLATION AND COMMISSIONING MANUAL CONTENTS. Function. Product range. Technical specifications. Characteristic components

RTL. Floor Heating Controller Return temperature limiter with and without presetting

LK Manifold Shunt VS2

Pump group DN 32 SA, SMT. Mounting and operating instruction

DISTRIBUTION GROUP WITH THERMOSTATIC REGULATION. Upper connections G1 F Without fittings Fittings with running connection* Without pump

PRODUCTS FOR HEATING AND TAP WATER SYSTEMS. Product Catalogue

PRESSURE CONTROL VALVES SABS 198

Catalogue Solar stations DN 20. Solar thermal solutions. Valid for the UK

Fuel Oil Deaerator with Integrated Filter Type GS 2000

Technical information Thermostatic radiator valves

INSTALLATION AND COMMISSIONING MANUAL CONTENTS. Function. Important Product range Technical specifications

GRUNDFOS DATA BOOKLET. Self-priming multistage pumps 50 Hz

Manually operated safety shut-off valve HSAV HSAV/5

Technical Product Submittal

Installation and Operation Instructions K31 HeatBloC - DN 50

Installation and Commissioning Instructions High Temperature Zone Module F31-1" (DN 25)

UNA 13 UNA 15 UNA 15 Stainless Steel Design. Installation Instructions Steam Traps UNA 13, UNA 15

TECHNICAL CATALOGUE DISTRIBUTION MANIFOLDS

Pump group DN 25 SA, SMTC, SMT. Mounting and operating instruction

Condensate Drain Valve AK 45. Original Installation Instructions English

underfloor heating PRODUCTS FOR UNDERFLOOR HEATING

Plate Heat Exchangers

Flow controller with integrated control valve (PN 16) AVQM - return and flow mounting

Data sheet Pressure independent control valve with integrated flow limiter AVQM (PN 16) - return and flow mounting

LK Manifold Shunt VS 2-2,5

RESOL SBS 1000 * * Connection Operation

HERZ-Motorised flow controler

Distributor for Floor Heating Systems

Installation and Operation Instructions K38 HeatBloC - DN 32

K35 HeatBloC with 3-temperature mixing valve

SIHI LPH-X - Liquid Ring Vacuum Pump Two Stage

3-Port Seat Valves with Male Thread, PN 16

V5032. Kombi-2-plus Manual double regulating balancing valve. Product specification sheet

Flow controller (PN 25) AVQ - return and flow mounting

Differential pressure controller with flow limitation and with integrated control valve (PN 16) AHPBM-F flow mounting, fixed setting

ETHERMA 4-SPEED CIRCULATOR PUMPS

Ballorex Vario. Description. Versions. Benefits. Applications. Balancing

V5000, V5010 Kombi-3-plus BALANCING AND SHUTOFF VALVES

Art.918C Pre-assembled manifold with flow meters, air

KFE Ball Valves The Benchmark for Quality and Reliability

Liquid ring vacuum pumps with magnetic coupling

Flow controller (PN 25) AVQ - return and flow mounting

Ball valve for pipeline systems

V2000UB UBG type TRV Body RADIATOR VALVE WITH UNLIMITED CARTRIDGE

Section 1 - Sanitary Manifolds

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves Electrically modulating GB-M(P) 057 D01

3-Port Seat Valves with Male Thread, PN 16

Air Operated Diaphragm Pumps for Sterile Applications within Pharmaceutical, Biotechnical and Food Industry

V2880, Therafix Design Thera Design Edition - H-Block with TRV Insert WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS

V2000FS FS type TRV Body FINELY PRESETTABLE RADIATOR VALVE WITH FLUSH POSITION

Technote. Frese ALPHA - automatic balancing valve. Application. Benefits. Features.

V2000Kx KV type TRV Body RADIATOR VALVE WITH KV-SPECIALIZED CARTRIDGE

Secondary Coolant 301

Section - B. Air vents

Productinformatie BAFA.NL BAFA.NL A.U.K. MÜLLER GMBH & CO. KG

GasMultiBloc Combined regulator and safety shut-off valves Single-stage function Integrated bypass valve MB-D(LE) B07

This catalog contains the following geothermal accessory products and specification guides:

Isolator Sandwich Plate

TDU.3 floor distribution unit SK

FCU Floor Control Unit

SIHI LPH-X - Liquid Ring Vacuum Pump Two Stage

Volute pumps for hot water

KLINGER. Instructions for installation and operation of. Reflex level gauges K D asbestos-free. wt 3017/11 Page 1.

Dewatering Submersible sewage pumps

Dynacon. Floor Heating Manifolds Floor heating manifold with automatic flow control

WORKSTATION PICTURE SHOWS PRODUCT WITH OPTIONS

TA-Mini-Fast-Fit. Prefab units Fabricated solutions for small terminal units

Valve monitoring system VDK 200 A S02

Two-port seat valves with male thread, PN16

Pressure independent control valve with integrated flow limiter AVQM (PN 16) - return and flow mounting

SECTION PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY

Transcription:

The Oventrop Quality Management System is certified to DIN-EN-ISO 9001 Application: The Oventrop programme for solar installations allows the connection of the collector to the storage cylinder within a solar circuit. Oventrop offers both, single components and pre-assembled units with suitable insulations. In installations in which the supply leading from the collector to the storage cylinder (heated collector liquid) and the return leading in opposite direction (cooled collector liquid) are installed in parallel, the Regusol-180 transmission unit is used. To guarantee an effective deaeration of the heat transfer medium, the supply of the transmission unit Regusol L-180 is additionally equipped with a deaerator. Should the pipes be installed apart, the pump circuit Regusol- 180 may be used. The filling and flushing device, being a part of the Regusol programme, serves to supply the solar circuit with collector liquid and to drain the system for maintenance work. To avoid any excess pressure within the solar circuit, the transmission unit and the pump circuit are equipped with a safety group to which an expansion tank may be connected. The Regusol components are suitable for commercial solar liquids base on glycols. Valves, controls + systems Valves and controls for solar installations Regusol-180 Transmission unit Regusol-180 Technical information Advantages: high functional efficiency all components from one supplier complete systems available material of high quality time-saving installation short-term max. starting temperature 160 C continuous max. working temperature 120 C with insulation Pump circuit Regusol-180 Transmission unit Regusol L-180 Filling and flushing device Regusol 2006 Oventrop 1

Tender specification/technical data: Transmission unit Regusol-180 with safety group for the connection to the solar circuit DN 25 by use of Regusol compression fittings (to be ordered separately). Complete, pre-assembled and leak tested unit facilitating the connection of a diaphragm expansion tank to the safety group: isolation of supply and return possible with adjustable flow measuring device with isolation facility for the regulation of the solar circuit with wall mounting device and insulation check valves in the supply and return Distance between supply and return: 100 mm Max. continuous working temperature: 120 C Max. short-term starting temperature: 160 C Max. working excess pressure (safety valve): 6 bar Opening pressure of check valve: 20 mbar Pump types: Grundfos UPS 25-60 Power consumption phase 1: 45 W phase 2: 65 W phase 3: 90 W Max. pump head: 6 m Max. pump capacity: 4.5 m 3 Wilo Star St 25/6 Power consumption phase 1: 34-44 W phase 2: 46-63 W phase 3: 68-82 W Max. pump head 6 m Max. pump capacity: 3.5 m 3 Wilo Star St 25/7 Power consumption phase 1: 44-63 W phase 2: 62-84 W phase 3: 92-110 W Max. pump head: 7 m Max. pump capacity: 4 m 3 Control ranges of flow measuring device: 2-15 l/min. 7-30 l/min. (only with Wilo pump St 25/7) Dimensions: 250 425 312 100 Transmission unit Regusol-180 250 425 312 G 3 4 Rp 3 4 G 3 4 Rp 3 4 Other models: Transmission unit Regusol L-180 with deaerator and safety group Same construction as Regusol-180 with additional deaerator for the deaeration of the heat transfer medium in the supply riser. Pump types: Wilo Star St 25/6 Grundfos UPS 25-60 Wilo Star St 25/7 Control ranges of flow measuring device: 2-15 l/min. 7-30 l/min. (only with Wilo pump St 25/7) 100 Transmission unit Regusol L-180 2 2006 Oventrop

Pump circuit Regusol-180 with safety group for the connection to the solar circuit DN 25 by use of the Regusol compression fittings (to be ordered separately). Complete, pre-assembled and leak tested unit facilitating the connection of a diaphragm expansion tank to the safety group. with isolation facility with adjustable flow measuring device with isolation facility for the regulation of the solar circuit with wall mounting device and insulation check valve integrated in the ball valve Max. continuous working temperature: 120 C Max. short-term starting temperature: 160 C Max. working excess temperature: 6 bar Opening pressure of the check valve: 20 mbar Pump types: Grundfos UPS 25-60 Wilo Star St 25/6 Control ranges of flow measuring device: 2-15 /min. Dimensions: 425 312 180 G 3 4 Rp 3 4 Function: The return of the transmission units Regusol-180, Regusol L-180 and of the pump circuit Regusol-180 is equipped with a ball valve with integrated check valve serving to avoid gravity circulation when the pump is switched off. The safety group is connected to the lateral connection piece of the ball valve and is equipped with a safety valve, a drain ball valve and a connection for a diaphragm expansion tank. The drainage pipe to a collecting basin is connected to the safety valve. The circulation pumps are especially suitable for use in solar circuits and are located in the return between the ball valve and the flow measuring device at which the fine setting of the flow rate can be carried out. In general, the required flow rate depends of the number of collectors or on the installation equipment. The flow measuring device can be shut off completely. The circulation pipe can easily be removed after isolation of the flow measuring device and the pump ball valve. The difference between the pump circuit Regusol-180 and the transmission unit Regusol-180 is the ntegrated supply pipe with an additional isolating ball valve with check valve. Both ball valves are equipped with thermometers. The wall mounting device which is supplied with each unit allows a fast installation. As the insulation made of expanded polypropylene consists of different elements, the unit may be easily insulated even where space is limited. A safe connection of the Regusol components to the pipework is carried out with compression fittings. The installation and operating instructions are to be observed! Pump circuit Regusol-180 Solar station Hot water Hot water supply Hot water return Cold water 2006 Oventrop 3

Further components for solar installations: Filling and flushing device Regusol for installation at the lowest point of the solar circuit with isolating ball valves, connection by use of compression fittings. 108 G 1 oventrop G 1 oventrop oventrop 3 4 male thread for hose connection 48.5 3 4 male thread for hose connection Compression fittings Regusol made of brass for the connection of the Regusol components to the solar circuit; suitable for copper and precision steel pipes. D Size D SW* 12 mm 12 37 15 mm 15 37 Attention: When installing copper pipes with a wall thickness of 1 mm, it is necessary to use reinforcing sleeves for the additional stabilisation of the pipe. Should the wall thickness exceed 1 mm, please contact the pipe manufacturer. SW 16 mm 16 37 18 mm 18 37 22 mm 22 37 *SW = spanner size Connection set Regusol for diaphragm expansion tanks for the connection of a diaphragm expansion tank to the solar station Regusol. Consisting of: hose 500 mm angled wall bracket 210 x 250 quick-coupling fixing material 250 225 210 120 30 8.5 5 L= 500 mm Flow measuring and regulating device, with isolation for Regusol-180 2-15 l/min. 7-30 l/min. L/MIN 15 12 9 7 5 2 Filling pump Regusol The filling pump Regusol serves to fill a solar installation with a heat transfer medium stored in an external tank. It is suitable for both, stationary and mobile use. 4 2006 Oventrop

Flow chart: Pressure lost p [mbar] Transmission unit Pump circuit Pressure lost p [kpa] Flow rate V [l/s] Pump curves: Pump UPS 25-60 Rp 1 Wilo-Star ST 25/6 1 230 V - Rp 1 2006 Oventrop 5

OVENTROP UK LTD. Unit I The Loddon Centre Wade Road Basingstoke, Hampshire RG24 8FL Great Britain Subject to technical modification without notice. Telephone (01256) 330441 Product range 6 Gedruckt auf Telefax chlorfrei (Sales) (01256) 330525 ti 108-1/10/MW Telefax (General) (01256) 470970 Edition 2006 gebleichtem E-Mail Papier. sales@oventrop.co.uk F. W. OVENTROP GmbH & Co. KG Paul-Oventrop-Straße 1 D-59939 Olsberg Germany Telephone (02962) 82-0 Telefax (02962) 82-450 E-Mail mail@oventrop.de Internet www.oventrop.de 2006 Oventrop 6