Instructions For Use VATEA. Endodontic Irrigation Device

Similar documents
OPERATING MANUAL POWER DRIVE SYSTEM. Cat. No RevH

OPERATION AND MAINTENANCE INSTRUCTION MANUAL. AEU-17B & AEU-17BV2 Implant / Surgery Systems

INSTRUCTION MANUAL. Tel / Fax SOM-S056S-KE Rev.5

Digital Apex Locator. ipex OPERATION MANUAL OM-E0285E

LLS-2054BE. Smart Battery Pack Operator Manual. ST Technologies 6018 Bowdendale Avenue Jacksonville, FL USA

BodyGuardTM 323. BodyGuard 323 Multi-Therapy Ambulatory Infusion Pump. Patient Guide

Instruction for Use (IFU)

OPERATION AND MAINTENANCE INSTRUCTION MANUAL. AEU-707A & AEU-707AV2 Implant / Surgery Systems

MEDICAL IRRIGATION K PUMP OPERATING MANUAL: Manufactured for: K.M.I 3185 Palisades Dr Corona CA USA Model No.

Endodontic Handpiece (GT) USER MANUAL

Before installing this unit, read the operating instructions carefully. Strictly adhere to these operating instructions.

Sentinel Enteral Feeding Pump. Model: S-1000-SI. Operating Manual

CURING LIGHT LED.B USER S MANUAL

DCell Suction. Model DM Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority

RemRest. Service Manual. CAUTION: USA Federal law restricts this device to sale by or on the order of a physician. P/N Rev A

OPERATION AND MAINTENANCE INSTRUCTION MANUAL. AEU-707A & AEU-707AV2 Implant / Surgery Systems

LED HANDHELD SLIT LAMP

Model 2310 Series. Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority

8000mAh Jump Starter User Manual

Quickdraw. Model 2400 Series. Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority

Instructions for use of S5 Endo Motor

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work

Podiatry Procedures Chair. For Models: Barrier-Free. User s Guide

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

SERVICE MANUAL Rocket Digital Oocyte Aspiration Pump

Nimbus Flex Ambulatory Infusion Pump

Thank you for purchasing the CHP Assembly Tool. In order to ensure maximum

6 Bay Battery Charger Operation Manual

SurePower Battery Pack Guide

SurePower TM II Battery Pack Guide

U10 Jump Starter. User Manual

GENERAL INFORMATION. H-1649, H-1650, H-1651 H-1653, H-1654 Easy-Count. uline.com. that may hurt accuracy:

OPERATION and MAINTENANCE INSTRUCTION MANUAL. AEU-7/AEU-7P Peristaltic Water Pump

K mAh Jump Starter

Model 605 Portable Aspirator

Xenon Fiberoptic Lightsource

Installation and user manual. 5SC 500i 5SC 750i 5SC 1000i 5SC 1500i ENGLISH. Copyright 2013 EATON All rights reserved.

c-go 24V/6A 24V/8A 24V/12A

SmartVent. Instructions for Use Version 4 (Dec 2009)

Rev ENGLISH..2

TPC. User Manual. LED 70N Cordless LED Curing Light

Uninterruptible Power System

Language specific user manuals are available on

Table of Contents. Classifications.. 5. Installation.,12. Focusing..14. Operating Instructions..15. Charts Description Maintenance...

VANGUARD A EZ INSTALL OPERATOR S MANUAL

Adam Equipment QT SERIES. ADAM EQUIPMENT CO. LTD. pn Rev. D1, July 2002

Technical manual. Hawker SmarTech. three phase

Quick Reference Guide

18VDC ESB6 Series Cordless Screwdrivers Operation Manual

Laerdal Compact Suction Unit 4

User Manual SONESTA S2 & S3

FILTRON 1-10 (DC/AC) BERMAD Irrigation

Pure sine wave charger inverter Product Manual

portable ac/dc suction pump USER S MANUAL ITEM # 18605

Installation Operation Maintenance Troubleshooting Version 1, Oct/09. Palm Beach

NB NB 1511 NB NB 4031 TRUE ON-LINE DOUBLE CONVERSION UPS

USER MANUAL READ THIS MANUAL BEFORE OPERATING THIS DEVICE. SAVE THIS MANUAL FOR FUTURE REFERENCE. DEALER: THIS MANUAL MUST BE GIVEN TO THE END USER.

OPERATION and MAINTENANCE INSTRUCTION MANUAL. ADU-12DCE Task Force Deluxe Portable Pneumatic Dental System

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual

Quolis Series. Quolis 5000 Chair IMPORTANT

Informer Compact Series

KILOTECH. KWD 500 Water tight. Portion/Weighing Scale

General warnings and cautions

Installation and user manual 5SC 500 5SC 750 5SC SC SC 500G 5SC 750G 5SC 1500G ENGLISH. Copyright 2013 EATON All rights reserved.

GRAVITY MEASUREMENT, INC.

FreeGo. pump. Training Manual. Freedom for life

1416 Cabinet Unit. Installation Operation Maintenance Troubleshooting Version Dec/17

User Manual. Charger for LTO Batteries. User Manual. Language specific user manuals are available on

MARINER MODEL WPS12 WATERPROOF DIGITAL PORTION SCALE OWNER S MANUAL

Clinical Electric OPERATION MANUAL

OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets

Power Inverter. User s Manual. Diamond Series CPD1200EILCD

Model 2008 I Battery Operated Irrigation Timer with 3/4 in. Anti-Siphon Valve

SURGICAL POWER & ACCESSORIES. Rx Only PM-X00-710/PM-X IR-12.13

GLO GT416. Benchtop Centrifuge. User s Manual. Glotech Co., Ltd

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

EMB-901 Built In Fiber Optic Brushless Electric Micromotor Set Operation Manual

Magstim MRI Coil Operating Manual

SR7 Micro-infusion Syringe Pump. Contents

OPERATION and MAINTENANCE INSTRUCTION MANUAL. AEU-70A Peristaltic Infusion Pump

SMP3CTX Series Power Supply/Charger

OPERATIONS GUIDE AND DIRECTIONS FOR USE

MULTI FUNCTIONAL COUNT CHECKER MODEL Poka Patrol CNA-4mk3

SECTION 2 5 OPERATION OF INSTRUMENTS AND CONTROLS. Gauges, Meters and Service reminder indicators

Ambulatory. Infusion. Pumps

GAN Electronic 600W/750W SE US

ca 5550SST Owner s Guide

DIGITAL BATTERY TORQUE WRENCH (BC-RAD SELECT) USER GUIDE

EFFECT 500 Mattress Overlay System

MOOG Medical Devices Group Curlin 6000 Series Ambulatory Infusion Pump PATIENT GUIDE

Parker Hannifin Corporation Porter Instrument Division 245 Township Line Road Hatfield, PA USA Tel: Ref.

U S E R M A N U A L SAVE THESE INSTRUCTIONS

TIME-10 Process Control Stopwatch

CONGRATULATIONS ON YOUR PURCHASE OF YOUR THUNDER SOLAR REGULATOR!

MOTORVAC. BrakeVac-II. MODEL NUMBER Brake Fluid Service System. Operator Manual MotorVac

General Precautions. Personnel Precautions

##CFG BWOP Manuals## Quasar elite HD-LED Mobile Models Assembly Guide

LED-HL2-CMP LED Headlight System Operation Manual

Universal Battery Charger II.

BrakeVac-II Brake Fluid Service System

Transcription:

Instructions For Use VATEA Endodontic Irrigation Device

VATEA Irrigation System Instructions for use 1. Indications for use The VATEA system is intended to be attached to dental handpieces to deliver irrigation during endodontic procedures. 2. Device description The VATEA system is a self-contained, fluid delivery unit consisting of a pump console, irrigation reservoir and disposable tubing intended to be used in endodontics to provide irrigation while attached to dental handpieces. The VATEA is an electronically operated device, powered by a rechargeable battery. Flow rate and timer is adjusted via control panel display, and the irrigation is toggled using a foot pedal. The unit has a positive displacement peristaltic pump to prevent fluid retraction thus avoiding patient cross-contamination. RD-040-130 VATEA IFU English - rev 4 Aug 1 st 2012 1

2.1 Description of the front panel LCD Display Battery Indication LED Flow Rate / timer Control Buttons Fluid Connection Socket (luer-lock) Foot Pedal Connection Socket Figure 1: Front panel of the VATEA RD-040-130 VATEA IFU English - rev 4 Aug 1 st 2012 2

2.2 Description of the rear panel Cap Liquid Reservoir Master On/ Off Power Switch Electrical Charger Socket Figure 2: Rear panel of the VATEA RD-040-130 VATEA IFU English - rev 4 Aug 1 st 2012 3

3. Precautions This device is to be used by dental professionals only. Batteries should be charged until indicating LED light changes to green. See instructions regarding batteries in paragraph 13. Electrical charger (medical AC/DC power supply adapter complies to UL60601-1) Make sure that the silicone tube and foot pedal cable are properly connected. Use only sodium hypochlorite in the reservoir. 4. Contraindications Do not use without a rubber dam. RD-040-130 VATEA IFU English - rev 4 Aug 1 st 2012 4

5. Getting started 5.1 Unpack the system carefully and place it on a flat, stable surface. 5.2 Connect the electrical charger power cable to the electrical charger socket on the rear panel. Charge the batteries until indicating LED light changes to green. 5.3 Connect the foot pedal plug and the fluids connector to the socket on the front panel: Position the foot pedal plug in a way that the marking arrow will be placed in front of the marking dot, as shown in figure 3(a). Push the plug until you hear a click sound. Tighten the luer-lock connector. To release the foot pedal plug turn it to the left as marked and pull it out. To release the fluid connector, screw it anti clockwise. (a) (b) Figure 3: Connecting (a) and disconnecting (b) the foot pedal plug and the fluids connector RD-040-130 VATEA IFU English - rev 4 Aug 1 st 2012 5

6. How to operate the VATEA system 6.1 Fill the reservoir with sodium hypochlorite, up to the 400ml indication line. It is required to use a funnel. Secure the cap. RD-040-130 VATEA IFU English - rev 4 Aug 1 st 2012 6

6.2 Assemble the silicone ring on the handpiece, as shown in figure 4: Figure 4: Assembly of the silicone ring on the handpiece 6.3 Turn on the system using the master power switch, located on the rear panel. Master On/ Off Power Switch RD-040-130 VATEA IFU English - rev 4 Aug 1 st 2012 7

6.4 Flow rate is displayed when the system starts up and/or when adjusting the flow rate. 6.5 Timer will start running when irrigation is switched on with the foot pedal. 6.6 The timer will count 10 minutes and then reset to "00" 6.7 During the first minute, the time is displayed in seconds (1-59 sec). 1 sec 59 sec 6.8 The following 9 minutes are presented in minutes (left digit), together with an indication of active irrigation by cyclic moving segments (right digit). RD-040-130 VATEA IFU English - rev 4 Aug 1 st 2012 8

1:00 min 1:01 min 1:02 min 1:03min 2 min 3 min 2 min 3 min RD-040-130 VATEA IFU English - rev 4 Aug 1 st 2012 9

6.9 A beeping sound will be heard after 2 minutes of operation. 6.10 When reaching 4 minutes, the buzzer indicates end of treatment, and the display starts blinking. The timer will keep running until stopped by the foot pedal. 6.11 Stopping the irrigation during the first 4 minutes stops the timer but does not reset it to "00". 6.12 Stopping the irrigation after 4 minutes with the foot pedal resets the timer. 6.13 A manual reset is possible by pressing the "+/-" control buttons on the front panel simultaneously. 6.14 An integrated buzzer is used for notifications and alarms (see section 9). (if it is desired to mute the buzzer the flow rate should be adjusted to zero and then the "+/-" control buttons pressed simultaneously. To turn on the buzzer again repeat this action). 6.15 When working with the electrical charger connected there will be a steady LED notification for the battery status. See LED indication table in paragraph 8. 6.16 When working with batteries, there will be a flashing LED notification according to the table in paragraph 8. 6.17 When the batteries discharge there will be a sound notification and a low battery icon notification on the screen before the system shuts down. 6.18 When connecting and disconnecting the electrical charger while the system is on, there will be a beeping sound. RD-040-130 VATEA IFU English - rev 4 Aug 1 st 2012 10

7. Equipment supplied VATEA irrigation system. 10 disposable Silicone tube 1.5m with silicone ring and luer-lock (cat no. RDN-MCH0027). Foot pedal (cat no. RDN-MCH0035). Electrical charger (cat no. RDN-MCH0023). Funnel. Instructions for use. Use only certified parts supplied by the manufacturer. Figure 5: Equipment supplied RD-040-130 VATEA IFU English - rev 4 Aug 1 st 2012 11

8. LED indication Color Green Orange Red Indication The batteries are fully charged The batteries are half-charged The batteries are NOT charged, soon to be empty RD-040-130 VATEA IFU English - rev 4 Aug 1 st 2012 12

9. Error messages Error message displayed on Control Panel screen Call service and E1 Call service and E2 Call service and E3 Call service and E4 Description Electronics overloaded The lifetime of the pump is soon to expire The lifetime of the pump has expired The foot pedal plug is disconnected from the front panel Solution Switch off the system, restart it and if this error reoccurs call technician Continue the treatment to its end, then use the + / - buttons to reset the display. Call a technician to replace the pump. There are still 50 hours of operation left after this message but the message will appear with every system turn on until the user presses the + / - buttons. The machine stops working after 450 hours of use. Switch off the system and call a technician. The error message will appear with every system turn on and system operation will not be permitted. The pump will stop immediately. Reconnect the foot pedal plug to the front panel and the pump will restart operation at the previous flow rate. RD-040-130 VATEA IFU English - rev 4 Aug 1 st 2012 13

10. Maintenance 10.1 Silicone tube and ring are disposable and should be discarded after use. Before initial use the tube should be sterilized in the dental clinic autoclave at 134 o C for 3 minutes. 10.2 VATEA outer surfaces Wipe with disinfection wipes after each treatment. 10.3 Charging - Connect the electrical charger until indicating LED light changes to green. 11. Technical data Power inlet: 220V AC@ 50-60 Hz or 110v@ 60Hz Supply voltage: 10V Current: 1.5A max Dimensions in mm: (HxWxD) 137x126x174 mm Weight in kg: 0.7 Kg Liquid reservoir capacity: 400ml Storage temperature: -10 C 60 C Operational temperature 10 C 40 C 12. Electrical Classification Type of protection against electrical shock: Internally powered equipment. Degree of protection against electrical shock: Type BF applied part. Degree of protection against ingress of water: VATEA: IPX0; Foot pedal: IPX1. RD-040-130 VATEA IFU English - rev 4 Aug 1 st 2012 14

Equipment not suitable for use in the presence of flammable anesthetic mixture with air or with oxygen or nitrous oxide. Mode of operation: Intermittent operation: Operation time: 20 minutes; Rest time: 20 minutes. 13. Precautions in Battery Handling 13.1 Be sure to connect the positive and negative battery terminals to the corresponding terminals of the application device, in order to prevent reverse charging. 13.2 Never incinerate the battery. 13.2 Avoid subjecting a battery to strong vibrations, pressure or impact. 13.3 Never carry a battery with other metallic belongings to avoid shortcircuiting. 13.4 Never disassemble a battery or a cell. 13.5 Never short together the positive and negative terminals of a battery with any metal. 13.6 Never alter the factory configuration or remove/modify a component of a battery. 13.7 Never use other charger than specified to avoid possible heating, burning or rupture. 13.8 If any abnormality or problem is found while using the battery, stop its use, and bring it to your local dealer. 13.9 Never use the battery for any applications other than specified, this may result in damage to the battery and the appliances. RD-040-130 VATEA IFU English - rev 4 Aug 1 st 2012 15

14. Symbols in use Symbol Description Read Instruction for use prior use XXXXXX Catalogue number XXXXXX Serial number Type BF applied part CAUTION, consult accompanying documents CE mark TUVus mark Class II RD-040-130 VATEA IFU English - rev 4 Aug 1 st 2012 16

15. Manufacturer ReDent-Nova Ltd. 15 Ha taasia Street, POB 4159 Ra anana 43000, Israel. Tel: +972 9 7445130 / 70, Fax: +972 9 7445190 E-mail: office@redent.co.il 16. European Representative Obelis s.a Boulevard Général Wahis 53 1030 Brussels, BELGIUM Tel: + (32) 2. 732.59.54 Fax: + (32) 2.732.60.03 E-Mail: mail@obelis.net RD-040-130 VATEA IFU English - rev 4 Aug 1 st 2012 17

P.O.B 4159, Ra anana 43000, Israel Tel: +972-9-744-5130 Fax: +972-9-744-5190 office@redent.co.il www.redent.co.il