Dome-Loaded Pressure Reducing BD-Series

Similar documents
MAR031615A 1. PABD Installation & Maintenance. Guide *Parts will differ for high pressure valves.

QPV1 Electronic Pressure Regulator INSTALLATION AND MAINTENANCE INSTRUCTIONS

BC Brake Caliper. (i) MEX (55) QRO (442) MTY (81) DIST. AUTORIZADO

Old Proportioning Pumps

Elgin Hydraulic Clutch-Brake ECB-240, Product Number FORM NO. L F FORM NO. L F-0704

FPC815 Pneumatic Rivet Tool

Air Operated Diaphragm Pumps Operating and Maintenance Instructions

CIRCLE SEAL CONTROLS

DAP-625S and DAP-875S

INSTALLATION, OPERATION & MAINTENANCE MANUAL

Installation, Operation and Maintenance Manual

CIRCLE SEAL CONTROLS

SERIES 7400 THREE PIECE BALL VALVES

Nor East. Instructions Safety Messages. Inspection. Parts. DeZURIK Service. Type 05 Pneumatic Actuator Used With Globe Valves

QB4 PRESSURE CONTROL VALVE INSTALLATION & MAINTENANCE INSTRUCTIONS

COOPER POWER SERIES. Screened Separable Connectors MN650023EN. Effective October 2016 Supersedes March 2012 (IS )

CRD600 Automatic Fitting Inserter

TBM Series 3-Way Ball Valve

AEROMOTIVE Part # Subaru STI Fuel Rail Kit INSTALLATION INSTRUCTIONS

COOPER POWER SERIES. Screened Separable Connectors MN650024EN. Effective October 2016 Supersedes March 2012 (IS )

Through-Shaft Clutch-Brake LSCB-32HT, LSCB-32HT, LSCB-44, LSCB-44HT, LSCB-54HT FORM NO. L D-0606 MEX (55) QRO (442)

Pump/Manifold Kits. Instructions F ENG. To convert E-Flo 4-Ball Piston Pumps to a different size lower. For professional use only.

Straight-Bore Clutch LSCC-32, 44, 54

FTIR PG28 PURGE GAS GENERATOR OPERATIONS & MAINTENANCE

CRD610 Automatic Fitting Inserter

LOW PRESSURE BALANCED VALVE DIAPHRAGM BALANCED

EPIC. Express Line Proudly Manufactured in the USA by Check-All Valve. Rev. E

Kimray reserves the right to modify or improve the designs or specifications of such products at any time without prior notice Kimray Inc.

AEROMOTIVE Part # L Ford F L Ford Expedition L Ford F-250 Super Duty INSTALLATION INSTRUCTIONS

Single Post Caliper Brake VC500

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

24G621 Agitator Speed Controller Accessory

# and # FAST Fuel System Kits

ALITA LINEAR AIR PUMP OPERATION & MAINTENANCE MANUAL. AL- Model Number Date Code / Serial Number Date of Purchase

AEROMOTIVE Part # Mustang 5.0L Fuel System Kit INSTALLATION INSTRUCTIONS

Model , Series A 9 in. (23 cm) roller frame with 45 angle and 12 in. reach 1/2 in. (13 mm) nap roller cover

AEROMOTIVE Part # /2 4.6L SOHC Ford Fuel Rail Kit INSTALLATION INSTRUCTIONS

OPW Installation and Maintenance Instructions OPW Series Primary and Secondary Bucket Replacement Instructions

300 Series INSTRUCTION MANUAL. Compressed Air Filters Models 302 (grade) through 317 (grade)

AEROMOTIVE Part # Subaru Fuel Rails for Top Feed Injectors WRX & STI INSTALLATION INSTRUCTIONS

Easytork Solenoid Valve IOM

Manufacturing Facility is ISO9001:2000. Welded Steel Pipe Conform to ASTM A53. Threads Conform to ASME B1.20.1

Ford Mustang Rear Decklid Spoiler Kit. Installation Instructions

Single-Position Detent Clutch DC Series. (i) MTY (81) MEX (55) QRO (442)

EZ-IN Series Turbine Flowmeter

Severe Duty Water Cannon Styles 3491 & 3492 Electric & Hydraulic

L007 LIQUID LEVEL FLOAT SWITCH. Side-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

Electrically Released Motor Brake Module for EM-MBFB and EUM-MBFB Size 50, 100, 180

Operating and Installation Instructions

ROUSH FUEL SYSTEM UPGRADE CURRENT FORD MUSTANG 5.0L

VSI INDUSTRIAL BALL VALVES SERIES 7100 SERIES 8100 SERIES 7200 SERIES 8300 SERIES 7400 SERIES 8400 SERIES 8000 SERIES 8500

COOPER POWER SERIES. 200 A Fused Loadbreak Elbow Connector Replacement Fuse Installation Instructions. Fusing Equipment MN132021EN

AEROMOTIVE Part # INSTALLATION INSTRUCTIONS

Effective November 2016 Supersedes February 2012 (S )

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

User Guide IGD Series

Severe Duty Water Cannon Styles 3491 & 3492 Electric & Hydraulic

AEROMOTIVE Part # L Ford F L Ford Expedition L Ford F-250 Super Duty INSTALLATION INSTRUCTIONS

GH-BETTIS SERVICE INSTRUCTIONS DISASSEMBLY & REASSEMBLY FOR MODELS HD521-M4, HD721-M4 AND HD731-M4 DOUBLE ACTING SERIES PNEUMATIC ACTUATORS

Temperature Sensor Series

CONTENTS. VIKING PUMP, INC. A Unit of IDEX Corporation Cedar Falls, IA USA SECTION TSM 710.1

Effective June 2016 New Issue

Mega-Flow External Damper Fans

Gen 2 Electrically Released Motor Brake Module for EM-MBFB and EUM-MBFB

Trimmer Auto Switch Series D- 7K/D-R K

SERIES 9000 Double Offset HP Butterfly Valves

Multi-Circuit Rotary Block

SUNTURA SOLAR TRACKER

Electric Pilot System Assembly, Operation, & Maintenance

PNEUMATIC SLIDING VALVE

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

FCB-450, LCB-600, MCB-800

The following is intended to provide the basic instructions for installation, operating and maintenance of the Severe Duty Monitor.

AEROMOTIVE Part # Fuel System Prime Kit INSTALLATION INSTRUCTIONS

COOPER POWER SERIES. 600 A 15/25 kv class T-OP II connector assembly installation instructions. Deadbreak Apparatus Connectors MN650048EN

ProFlo FatBoy

390 Airless Sprayer. Parts J EN. Models: , , , , , ,262024, , , , Hi-Boy.

EZ Carrier 3. Owner s Manual. Keep instructions for future reference

MINI AIR ANGLE DIE GRINDER

Liquid Turbine Flowmeter

DeZURIK PEC ECCENTRIC VALVES

Electric Pilot System

SUNTURA HD SOLAR TRACKER

AEROMOTIVE Part # & ½ L DOHC Return Style Fuel System Kit INSTALLATION INSTRUCTIONS

HATCHGRIP Installation Instructions/Operation and Maintenance Manual

Installation, Operation and Maintenance Manual

STRAIGHT DIE GRINDER MODEL EGA530 OWNERS MANUAL

BMK-30. Heavy-Duty By-Pass Filtration System Installation and Servicing Instructions

Pneumatic Cylinder 14 Bore X 21 Stroke Part No. P Replaces Part No. P

1451 Control Valve. General Instructions. Table of Contents

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

ASM Maxi Poles. Instruction-Parts B Series. For the application of architectural paints and coatings.

UV PROCESS SUPPLY, INC.

MOTORIZED FOLDING CAMPER WINCH

HIGH PRESSURE CONTROL VALVE PISTON BALANCED

AEROMOTIVE Part # Generic Fuel System Kit INSTALLATION INSTRUCTIONS

Instruction Sheet SRSR SERIES. Rotating Sliding Rail System

J 6 Se r i e s. Pressure and Vacuum switches. features

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080

"WHERE TUBING AND FITTINGS COME TOGETHER"

Transcription:

Dome-Loaded Pressure Reducing BD-Series *Parts will differ for high pressure valves. Load Piston - Piston - U-cup U-cup Piston 1. Carefully place the u-cup over the neck of the piston. Load Cylinder - Cylinder - Static Seal O-ring - Seat Seat Static Seal O-ring 1. Place the cylinder on the tabletop with Cylinder the mounting flange facing up. 2. Apply a thin layer of grease to the internal walls of the cylinder as well as the external walls of the piston. 3. Carefully press the U-cup attached to the piston into the center opening of the cylinder. (The top of the piston should rest slightly below the top surface of the cylinder.) 4. Flip the cylinder so that the mounting flange is resting on the tabletop and place the static seal O-ring over the cylinder allowing it to rest on the mounting flange. 5. Place the seat over the cylinder so it rests on the shoulder of the cylinder. Piston/U-cup.v3 1

Load Stem Gasket Seal O-ring - Gasket Seal O-ring - Stem 1. Place (1) gasket seal O-ring over the threaded end of the stem and move it down until it rests on the top shoulder of the stem. Stem Internal Assembly - Gasket Seal O-ring 1. Insert the stem into the center opening of the cylinder allowing the hex and threaded portion to pass through the center of the piston. 2. Place (1) gasket seal O-ring over the threaded end of the stem to rest on the top face of the piston. Gasket Seal O-ring Loaded Cylinder Loaded Stem.v3 2

Load Valve Body Torque Values Chart - Lower Spring (Where applicable) - Valve Body - Internal Assembly - 1/16 NPT Brass Plug - Hex Head Cap Screws (Cylinder Bolts) NOTE: Refer to page 6 and 7 for the necessary tools list for each unit. 1. Place the lower spring into the valve body concentric with the casted stem guide in the bottom portion of the valve body. (Where applicable) 2. Apply a thin layer of grease to the internal walls of the top center opening on the valve body as well as the outer walls of the cylinder. 3. Insert the internal assembly into the valve body with the hex end of the Hex Head Cap Screw stem stud facing upward. 4. Align the (3) cylinder mounting holes with the internal mounting holes on the valve body. 5. Grease then tighten (3) hex head cap screws (cylinder bolts) into the mounting holes using a 1/2" drive tool. Lower Spring 6. Using a 1/2 (Where applicable) heavy socket NPT Plug head and a torque wrench, tighten the hex head cap screws (cylinder bolts) to 18 ft/lbs. 7. Tighten until torque wrench Valve Body clicks. 8. Based on the valve specifications apply Teflon tape and tighten either a drilled or undrilled NPT plug into the internal sensing port using the appropriate Allen wrench..v3 3

Diaphragm Assembly Torque Values Chart *Grade 8 bolts, increase torque value by 15% - Lower Membrane Plate - Gasket Seal O-ring - Membrane - Upper Membrane Plate - SS Jam Nut (Stem Nut) - Dome - Hex Head G5 Cap Screws (Body Bolts) - Hex G5 Nuts (Body Nuts) - 1/4" NPT SS Plug - NOTE: Refer to page 6 and 7 for the necessary tools list for each unit. Image on page 5 for this procedure 1. Place the lower membrane plate over the stem with the machined grooves face up. 2. Place (1) gasket seal O-ring over the stem to rest on the lower membrane plate. 3. Die cut the membrane using the membrane steel rule die. 4. Place the center hole of the membrane over the stem allowing it to rest on the gasket seal O-ring and the lower membrane plate. 5. Place the upper membrane plate over the stem with the interlock face resting on the membrane. 6. Hand-tighten the SS jam nut (stem nut) down onto the top face of the upper membrane plate. 7. Use the appropriate wrench to hold the SS jam nut (stem nut) in place while using the appropriate heavy socket head on a torque wrench set to the appropriate torque value. 8. Tighten until torque wrench clicks. 9. The valve can now undergo a seat test to insure the unit is functioning properly. 10. Align the mounting holes on the dome with the mounting holes on the valve body; orient the dome with the part number facing to the front of the unit and with the pilot ports in line with the inlet and outlet ports. 11. Grease then hand-tighten (8) hex head G5 cap screws (body bolts) into the mounting hole on the valve body with (8) hex G5 nuts (body nuts) on the bottom of the mounting flange. 12. Tighten the hex head G5 cap screws (body bolts) using the appropriate socket head holding the hex G5 nuts (body nuts) in place and the appropriate heavy socket head on a torque wrench set to the appropriate torque value. 13. Tighten until torque wrench clicks. 14. Apply Teflon tape and then thread (1) 1/4" SS NPT plug into the right-hand side pilot port on the top face of the dome using a 1/4" Allen wrench. 15. Based on the valve specifications apply Teflon tape and then thread (1) 1/4" SS NPT plug into the external sensing port on the back side of the valve body. 16. The valve is now ready to be tested with a piloting regulator (Fairchild)..v3 4

1/4" NPT SS Plug Hex Head G5 Cap Screw Dome Upper Membrane Plate SS Jam Nut Membrane Gasket Seal O-ring Lower Membrane 1/4" NPT SS Plug Hex G5 Nut.v3 5

BD Valve Assembly Section View.v3 6

Master Tools List Tools List (1/2 to 1 inch Bodies) 5/32 Allen Wrench (Internal Plug) 1/4 Allen Wrench (External Plug) 1/2 Socket Head (Cylinder Bolts) 1/2 Heavy Socket Head (Stem Stud) 9/16 Socket Head (Body Bolts) 9/16 Wrench (Body Nuts) 15/16 Wrench (Stem Nuts) Torque Wrench (Set to 18 ft/lbs) (Cylinder Bolts) Torque Wrench (Set to 35 ft/lbs) (Body Bolts) Torque Wrench (Set to 85 ft/lbs) (Stem Nut) Tools List (1-1/2 inch Body) 5/32 Allen Wrench (Internal Plug) 1/4 Allen Wrench (External Plug) 1/2 Socket Head (Cylinder Bolts) 9/16 Socket Head (Body Bolts) 9/16 Heavy Socket Head (Stem Stud) 9/16 Wrench (Body Nuts) 1-1/8 Wrench (Stem Nut) Torque Wrench (Set to 18 ft/lbs) (Cylinder Bolts) Torque Wrench (Set to 35 ft/lbs) (Body Bolts) Torque Wrench (Set to 130 ft/lbs) (Stem Nut) Tools List (2 inch Body) 5/32 Allen Wrench (Internal Plug) 1/4 Allen Wrench (External Plug) 1/2 Socket Head (Cylinder Bolts) 5/8 Socket Head (Body Bolts) 9/16 Heavy Socket Head (Stem Stud) 11/16 Wrench (Body Nuts) 1-1/8 Wrench (Stem Nut) Torque Wrench (Set to 18 ft/lbs) (Cylinder Bolts) Torque Wrench (Set to 40 ft/lbs) (Body Bolts) Continue to next page Torque Wrench (Set to 130 ft/lbs) (Stem Nut) Tools List (3 inch Body) 3/16 Allen Wrench (Internal Plug) 1/4 Allen Wrench (External Plug) 1/2 Socket Head (Cylinder Bolts) 5/8 Socket Head (Body Bolts) 11/16 Wrench 3/4 Heavy Socket Head 1-1/2 Wrench Torque Wrench (Set to 18 ft/lbs) Torque Wrench (Set to 40 ft/lbs) Torque Wrench (Set to 160 ft/lbs) Tools List (4 inch Body) 3/16 Allen Wrench 1/4 Allen Wrench 1/2 Socket Head 5/8 Socket Head 11/16 Wrench 3/4 Heavy Socket Head 1-1/2 Wrench Torque Wrench (Set to 18 ft/lbs) Torque Wrench (Set to 40 ft/lbs) Torque Wrench (Set to 160 ft/lbs).v2 7

BURLING VALVE, LLC. Safety Precautions Please read all of the following Safety Precautions before installing or operating any Burling Valve, LLC equipment or accessories. To confirm safety, be sure to observe ISO 4414: Pneumatic Fluid Power - General rules relating to systems and other safety practices. Warning Improper operation could result in serious injury to persons or loss of life! 1. PRODUCT COMPATIBILITY Burling Valve, LLC products and accessories are for use in industrial pneumatic applications with compressed air media. The compatibility of the equipment is the responsibility of the end user. Product performance and safety are the responsibility of the person who determined the compatibility of the system. Also, this person is responsible for continuously reviewing the suitability of the products specified for the system, referencing the latest catalog, installation manual, Safety Precautions and all materials related to the product. 2. EMERGENCY SHUTOFF Burling Valve, LLC products cannot be used as an emergency shutoff. A redundant safety system should be installed in the system to prevent serious injury or loss of life. 3. EXPLOSIVE ATMOSPHERES Products and equipment should not be used where harmful, corrosive or explosive materials or gases are present. Unless certified, Burling Valve, LLC products cannot be used with flammable gases or in hazardous environments. 4. AIR QUALITY Clean, dry air is not required for Burling Valve, LLC products. However, a 40 micron particulate filter is recommended to prevent solid contamination from entering the product. 5. TEMPERATURE Products should be used with a media and ambient environment inside of the specified temperature range of 32 F to 158 F. Consult factory for expanded temperature ranges. 6. OPERATION Only trained and certified personnel should operate electronic and pneumatic machinery and equipment. Electronics and pneumatics are very dangerous when handled incorrectly. All industry standard safety guidelines should be observed. 7. SERVICE AND MAINTENANCE Service and maintenance of machinery and equipment should only be handled by trained and experienced operators. Inspection should only be performed after safety has been confirmed. Ensure all supply pressure has been exhausted and residual energy (compressed gas, springs, gravity, etc.) has been released in the entire system prior to removing equipment for service or maintenance. BURLING VALVE, LLC 8250 N. 600 West McCordsville, IN 46055 317.335.2602 Caution Improper operation could result in serious injury to persons or damages to equipment! 1. PNEUMATIC CONNECTION All pipes, pneumatic hose and tubing should be free of all contamination, debris and chips prior to installation. Flush pipes with compressed air to remove any loose particles. 2. THREAD SEALANT To prevent product contamination, thread tape is not recommended. Instead, a non-migrating thread sealant is recommended for installation. Apply sealant a couple threads from the end of the pipe thread to prevent contamination. 3. ELECTRICAL CONNECTION To prevent electronic damage, all electrical specifications should be reviewed and all electrical connections should be verified prior to operation. Exemption from Liability 1. Burling Valve, LLC is exempted from any damages resulting from any operations not contained within the catalogs and/or instruction manuals and operations outside the range of its product specifications. 2. Burling Valve, LLC is exempted from any damage or loss whatsoever caused by malfunctions of its products when combined with other devices or software. 3. Burling Valve, LLC and its employees shall be exempted from any damage or loss resulting from earthquakes, fire, third person actions, accidents, intentional or unintentional operator error, product misapplication or irregular operating conditions. 4. Burling Valve, LLC and its employees shall be exempted from any damage or loss, either direct or indirect, including consequential damage or loss, claims, proceedings, demands, costs, expenses, judgments, awards, loss of profits or loss of chance and any other liability whatsoever including legal expenses and costs, which may be suffered or incurred, whether in tort (including negligence), contract, breach of statutory duty, equity or otherwise. Warranty Burling Valve, LLC products are warranted to the original purchaser only against defects in material or workmanship for one (1) year from the date of manufacture. The extent of Burling Valve s liability under this warranty is limited to repair or replacement of the defective unit at Burling Valve s option. Burling Valve shall have no liability under this warranty where improper installation or filtration occurred.