Directional Control Valves. Features. Application. Operation

Similar documents
Directional Control Valves Series D81V. General Description. Operation. Features. Specifications

Directional Control Valves. General Description. Operation. Features

Operation. D1VW Solenoid Operated Plug-In Conduit Box Style

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Directional Control Valves. Application. Features. Operation.

Directional Control Valves. Features. Application. Operation

Directional Control Valves. Features. Application. Operation

Directional Control Valves. General Description. Operation. Features

Directional Control Valves. Application. Features. Operation

Directional Control Valves. Application. Features. Operation

Directional Control Valves. General Description. Operation. Features

Operation. D1VW Solenoid Operated Plug-In Conduit Box Style

Operation. D1VW Solenoid Operated Plug-In Conduit Box Style

Directional Control Valves

Directional Control Valves. Application. Features. Operation. D3W Solenoid Operated Conduit Cavity Style. D3W Solenoid Operated Hirschmann (DIN) Style

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Directional Control Valves. General Description. Features. Specifications

Directional Control Valves Series D111VW. General Description. Features. Performance Curves

Operation. D3W Solenoid Operated Conduit Box Style. D3W Solenoid Operated Hirschmann (DIN) Style

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Série D3 Válvula Direcional CETOP 5 e NG 10. Catálogo HY /US

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Hydraulics 1. Directional Control Valves Series D1M. Features. Application. Operation. D1MW Solenoid Operated Free Lead Wire

Bulletin HY M6/US Service Bulletin. Series D1VW, H Style 91 Design. Effective: May 1, Directional Control Valves

Bulletin HY M2/US Service Bulletin. Series D1VW, C Style 91 Design. Effective: May 1, Directional Control Valves

Directional Controls

Directional Controls

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

Bankable Control Valves

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

Directional Control Valves. General Description. Features. Specifications

Direct Operated Proportional DC Valves

EManually Operated Directional Valves

High Pressure, Subplate Mounted Directional Control Valves

High Pressure, Subplate Mounted Directional Control Valves

Directional Controls

Manapak Sandwich Valves. General Description

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

VSD10M DIRECTIONAL CONTROL VALVES SOLENOID ACTUATED, PILOT OPERATED

Series Shockless Type Solenoid Controlled Pilot Operated Directional Valves

Bar 35 PSI 500. Pressure Drop L/M GPM. Flow

Pilot-Operated Directional Control Valves Series D3 - D11

EManually Operated Directional Valves

Pilot Operated Directional Control Valves Series D31DW, D41VW - D111VW

Pilot Operated Directional Valves

Directional Control Valve Series 4D01 (DENISON)

D07 & D08. Series 35 Solenoid Valves D07 D Friendship Drive, Magnolia, TX Tel.: Fax:

DIRECTIONAL CONTROLS. Pilot Operated Directional Valves. Specifications

"G" SERIES SHOCKLESS TYPE SOLENOID OPERATED DIRECTIONAL VALVES G-DSG-01/03 (1/8, 3/8) "G" SERIES SHOCKLESS TYPE

Chapter 2: Directional Control Valves

385 & 962 Series The lectroaire valve is a compact, air operated, electrically lectroaire valves can be remotely mounted for control of double acting

4/2- and 4/3-Way Proportional Directional Control Valve Direct Operated, Model 4 WRA (Series 1X) PSI (315 bar) H/A 1768

DFE10. solenoid control monoblock valve. Ordering codes. Description example : Diverter valve DFE10/3 A 18 ES - W VDC - SAE - <CVN>

Monobloc and Sectional Directional Control Valves

Directional Controls

Directional control valves NG6...NG32 D03...D10 6

Directional Control Valve Series D1VW

ANTI-SHOCK DIRECTIONAL CONTROL VALVES

Pilot Operated Directional Valves

Monobloc and Sectional Directional Control Valves

Directional Control Valves

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

Pilot Operated Directional Control Valves Series D31DW, D31NW, D*1VW

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

High Response Type Proportional Electro-Hydraulic Directional and Flow Control Valves

Monobloc and Sectional Directional Control Valves

BST / BSG-03 / 06 / 10 Threaded Connections / Sub-plate Mounting. Specifications / Model Number Designation. Max. Flow L/min (U.S.GPM) Double Sol.

Pilot Operated Pressure Relief Valve Series R5V (Denison)

EMechanically Operated Directional Valves

MDT. Monoblock directional control valves MDT - Directional control valve

Cable Appendix. Valves. Cable Appendix. Page 16. Multi-way cables. D-sub Connector Cables. AXT100-DS Conforming to MIL-C-24308

Directional Control Valve Series D3W (Parker), 4D02 (Denison)

Mounting and Assembly of Sandwich Bodies

Sc h rader Bellows. CS Series Air Control Valves. 2 & 3-Way, Inline, Manifold & Stacking Direct Acting Solenoid Valves

Solenoid Valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) A-1.

Pressure Compensator Valves Series R5P (SAE Flange Mounted) General Description. Features

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

Directional Control Valve

Directional Control Valves

RA / Accumulator unloading valve, pilot operated, Model DA 6 V.., series 4X. Ordering details DA 6 V 4X. Preferred models 1/8.

3/2 Way Valve G1/8. Data Sheet No E. Characteristics Symbol Unit Description General Features Spool valve.

These valves may be used to manually shift the spool position and change the direction of oil flow *2 1.8

Monobloc and Sectional Directional Control Valves

3/2 and 4/2 directional seat valves with solenoid actuation

Pump Safety Block Model DBA... / DBAW, Series 1X

Solenoid directional valves type DPHI, DPHE, DPHER two stage, ISO 4401 size 10, 16, 25 and 32

4/3 and 4/2 on-off directional valve elements D8_5 with or (EDD-XZ) without secondary relief valves and with or without LS connections D8_5 (EDD-XZ)

Solenoid valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm)

Hydraulic Power Units D, H, V-Pak and V-Pak Low Profile Series

SECTION TITLE HEC2003/2004 SERIES SERVO VALVE SYSTEM ACCESSORIES KEY FEATURES

RELIEF VALVES Remote Control / Direct Type Pilot Operated / Solenoid Controlled

Pressure Control Valves Series R. General Description. Specifications. Flow Data

3/2 and 4/2 directional poppet valve with solenoid actuation

4-Way, 5-Port, 2 & 3-Position Solenoid and Remote Pilot 1/2" & 3/4" Ports. Technical & Service Data. Pneumatic

Introduction. Pressure drops

RA / /3, 4/2 and 3/2-Way Directional Valves Model.WE 10.../.D, Series 3X with Wet Pin DC Solenoids. Functional description, section

4/3-4/2 Directional valve elements with or without secondary relief valves, and with or without LS connections

SV9A-10-E - Solenoid Valve 4-way, 3-position spool type solenoid valve Up to 36 L/min (9.5 USgpm) 210 bar (3000 psi)

3/2 and 4/2 directional seat valves with solenoid actuation

Directional Controls

Transcription:

Introduction pplication hydraulic directional control valves are high performance, solenoid controlled, pilot operated, 2-stage, 4-way valves. hey are available in 2 or 3-position styles and are manifold mounted. hese valves conform to NF s D05H, CEO 5 and can also be manufactured to an NF DO5HE, CEO 5H configuration. Operation directional valves consist of a 5-chamber style main body, a case hardened sliding spool, and a pilot valve or pilot operators (hydraulic or pneumatic). Features Easy access mounting bolts. 345 ar (5000 SI) pressure rating. Flows to 175 LM (45 GM) depending on spool. Choice of four operator styles. Rugged four land spools. Low pressure drop. hosphate finish. oth NF and CEO mounting styles available. LH D31*W Solenoid Operated lug-in Conduit ox D31*L Lever Operated D3* Oil ilot Operated D31* ir ilot Operated 78 Elyria, Ohio, US

echnical Information General directional control valves are 5-chamber, pilot operated, solenoid controlled valves. he valves are suitable for manifold or subplate mounting. Features World design vailable worldwide. Mounting bolts below center line of spool Minimizes spool binding. Five chamber style Eliminates pressure spikes in tubes, increasing valve life. High pressure and flow ratings Increased performance options in a compact valve. Specifications Mounting attern NF D05H, CEO 5 NF D05HE, CEO 5H Max. Operating ressure Max. ank Line ressure Max. Drain ressure 345 ar (5000 SI) Standard 207 ar (3000 SI) 10 Watt CS 207 ar (3000 SI) Internal Drain Model: 103 ar (1500 SI) C Std. 207 ar (3000 SI) DC Std./C Opt. External Drain Model: 207 ar (3000 SI) CS 103 ar (1500 SI) 103 ar (1500 SI) C only 207 ar (3000 SI) DC Std./C Opt. CS Min. ilot ressure 6.9 ar (100 SI) 103 ar (1500 SI) Max. ilot ressure 345 ar (5000 SI) Standard Nominal Flow Maximum Flow CS 207 ar (3000 SI) 76 Liters/Min (20 GM) See Switching Limit Charts Response ime Response time (milliseconds) at 345 ar (5000 SI) is 76 LM (20 GM) Solenoid ilot ype ressure ull-in Drop-Out 500 40 50 DC 1000 36 50 2000 34 50 500 20 33 C 1000 18 33 2000 13 33 LH Switching Limit Charts SI ar 5000 345 4000 276 For Styles F and M external drain only (For internal drain see note below) 6.9 ar (100 SI) pilot 2,7 (14) 1, 3, (15), 4, 5 (16), 6, 11 Supply ressure 3000 207 2000 138 1000 69 9 8 9 with 150 SI ilot 0 LM 0 GM 38 76 113 151 189 10 20 30 40 50 Flow Note: Internal Drain 1, 4 spools 113 LM (30 GM) max., 2, 9 & 14 spools per curve ll others 95 LM (25 GM) max. 79 Elyria, Ohio, US

Ordering Information D Directional Control Valve asic Valve ctuator Spool Style ilot Supply Seal Solenoid and Drain Voltage LH 31D NF D05HE, CEO 5H, DIN NG10, D03 ilot, ISO ort 31V NF D05H, CEO 5, D03 ilot, NF ort Symbol Symbol 001 011 002 012 003 014 004 015 005 016 006 020* 007 030** 008* 081 009** 010 082 W# Solenoid, Wet in, Screw-in HW# Reversed Wiring # Valve schematic symbols are per NF/ NSI standards, providing flow to when energizing solenoid. Note operators reverse sides for #008 and #009 spools. See installation information for details. o configure per DIN standards ( coil over port, coil over port) code valves as D31VHW***. * 008 & 020 spools have closed crossover. ** 009 & 030 spools have open crossover. N V Nitrile Fluorocarbon ** D G J K N*** *** Q** QD R U Y 24/50 VC 120 VDC 198 VDC 24 VDC 12 VDC 220/50 VC 110/50 VC 100/60 VC 100 VC/60 Hz 100 VC/50 Hz 24/60 VC 240/60-220/50 VC 98 VDC 120/60-110/50 VC Z 250 VDC ** High watt only. *** Explosion proof only. vailable in DIN only. Symbol * Single solenoid, 2 position, spring offset. to and to in offset position. C Double solenoid, 3 position, spring centered. D* Double solenoid, 2 position, detent. E Single solenoid, 2 position, spring centered. to and to when energized. F Single solenoid, 2 position, spring offset, energized to center. Spacer on side. to and to in offset position. H* Single solenoid, 2 position, spring offset. to and to in offset position. K 1* Internal ilot, External Drain 2* External ilot, External Drain 4# Internal ilot, Internal Drain 5 External ilot, Internal Drain * F and M style available only with external drain. # Not available with 002, 007, 008, 009 or 014 spools. Single solenoid, 2 position, spring centered. to and to when energized. M Single solenoid, 2 position, spring offset, energized to center. Spacer on side. to and to in offset position. * 020 and 030 spools only. High watt only. old: Designates ier I products and options. Non-old: Designates ier II products and options. hese products will have longer lead times. b b b b b a a a a a 80 Elyria, Ohio, US

Ordering Information Solenoid Connection C* Leadwire Conduit ox D** Metric lug (M12X1), DESIN E Explosion roof G lug-in Conduit ox J# Deutsch (D06-2S) M# Metri-ack (150) DIN with lug S# Dual Spade W DIN w/o lug * No variations See lug-in. ** DC only, lights, diode surge suppressor, not CS approved. Not available with lights. Required for variations on conduit box style. Must have lights. # DC only, no lights, not CS approved. Omit* D** E** High Watt Explosion roof, EEXD EX Explosion roof, EEXME EX F Low Watt L O** 10 Watt Explosion roof, MSH Coil Options # Explosion roof, Ex d IIC EX/CS U ** Explosion roof, UL/CS * C ambient temperature must not exceed 60 C (140 F). ** 60 Hz only on C, no options. C only. DC and C rectified only. # J, K and Y voltages only. Dual frequency on C, no options. Valve Weight: Double Solenoid 5.4 kg (12.0 lbs.) Seal Kit: Nitrile SKD31VWN91 Fluorocarbon SKD31VWV91 Omit ube Options Omit Manual Override Options Standard ressure 103.5 ar (1500 SI) C 207 ar (3000 SI) DC H* High ressure, C only 207 ar (3000 SI) * Not available with CS. Standard None Extended with oot DC or C rectified only. Manual Override options not available with Explosion roof. Omit Electrical Options No Options J* Diode Surge Suppressor Z Rectified Coil * DC only. DIN coil must include plug with lights. DC tube standard. Mounting olt Kits Shift pprovals Response and Indication Omit Standard Valve 3* CS US Valve Variations See next page for Valve Variations 4*# CS pproved * Not available with C high pressure tube. # Valve is derated with this option., C, H styles only. J, K, Y, U voltages only with C, G, W solenoid connections only. Conforms to UL429. UNC olt Kits for use with D31*W & Sandwich Valves Number of Sandwich Valves @ 2.00 (50mm) thickness Design Series NOE: Not required when ordering. 0 1 2 3 D31*W Standard: K98 K141 K142 K143 1.62 3.50 5.50 7.50 Metric: KM98 KM141 KM142 KM143 40mm 90mm 140mm 190mm NOE: ll bolts are SE grade 8. Standard bolts are 1/4-20 UNC thread. Metric bolts are M6-1.0 thread. orque to 16 Nm (12 ft-lbs). old: Designates ier I products and options. Non-old: Designates ier II products and options. hese products will have longer lead times. Omit I3 I6 Standard Response, No Switch Monitor Switch, & ort End Monitor Switch, & ort Start Note: Not CE or CS approved. Spools 008, 009, 081 and 082 not available. LH 81 Elyria, Ohio, US

Ordering Information Valve Variations 5* Signal Lights Standard 7** Signal Lights Hirsch. (DIN with lug) Manaplug rad Harrison (12x1) Micro with Lights 56** Manaplug (Mini) with Lights 20 Fast Response 1C** 1D** 1G** 1H** 1M** 1 1R 3 3 3C 3D 3E 3F Manaplug (Mini) Single Sol. 5-pin, with Lights Manaplug (Micro) Single Sol. 5-pin, with Lights Manaplug (Mini) Single Sol. 5-pin, with Stroke djust & End and Lights Manaplug (Micro) Single Sol. 5-pin, with Stroke djust & End and Lights Manaplug Opposite Normal ainted ody Stroke djust & End with ilot Choke Meter In ilot Choke Meter Out ilot Choke Meter In ilot ressure Reducer Stroke djust End Stroke djust End Stroke djust & End 3G* ilot Choke Meter Out with Lights 3H* ilot Choke Meter In with Lights 3J* ilot ressure Reducer with Lights 3K 3L** 3M 3R 3S** 7Y** ilot Choke Meter Out with Stroke djust & End ilot Choke Meter Out, Stroke djust & End with Lights and Manaplug rad Harrison Mini ilot Choke Meter Out, ilot ressure Reducer, Stroke djust & End ilot Choke Meter Out & ilot ressure Reducer Lights, Mini Manaplug, ilot Choke Meter Out M12x1 Manaplug (4-pin), Special Wiring, and Lights * DESIN, plug-in conduit box, and DIN with plug styles only. ** Must have plug-in style conduit box. LH 82 Elyria, Ohio, US

echnical Information D31 Series ressure Drop vs. Flow he chart below provides the flow vs. pressure drop curve reference for the D31 Series valves by spool type. Example: Find the pressure drop at 76 LM (20 GM) for a D31 with a number 1 spool. o the right of spool number 1, locate the number 3 in the - column, and 2 in the - column. Using the graph at the bottom, locate curves 2 and 3 and read the pressure drop values. otal pressure drop through the valve is the sum of the two values. Note: ressure drops should be checked for all flow paths, especially when using non-symmetrical spools (003, 005, 007, 014, 015 and 016) and unbalanced actuators. D31 ressure Drop Reference Chart Curve Number Spool Shifted Center Condition No. - - - - (-) (-) (-) (-) (-) (-) (-) 001 3 3 2 1 - - - - - - - 002 3 3 1 1 3 3 3 4 4 1 1 003 3 3 1 1 - - - - - 3-004 3 3 1 1 - - - - - 1 1 005 3 3 1 1 - - - 5 - - - 006 3 3 1 1-5 7 6 5 - - 007 4 2 1 1 4 - - - 3-2 009 3 3 1 1 7 - - - - - - 010 3 2 - - - - - - - - - 011 3 2 1 1 - - - - - 8 8 014 2 4 1 1 4 - - 4-2 - 015 3 2 4 1 - - - - - - 4 016 5 2 1 1 - - - - 5 - - 020 5 4 2 2 - - - - - - 030 4 3 1 1 - - - - - - LH erformance Curves Viscosity Correction Factor Viscosity 75 150 200 250 300 350 400 (SSU) % of 93 111 119 126 132 137 141 (pprox.) Curves were generated using 110 SSU hydraulic oil. For any other viscosity, pressure drop will change per chart. 83 Elyria, Ohio, US

echnical Information Solenoid Ratings Insulation System Class F llowable Deviation -15% to +10% for DC and C rectified coils from rated voltage -5% to +5% for C Coils rmature CS File Number Environmental Capability Wet pin type LR60407 DC Solenoids meet NEM 4 and I67 when properly wired and installed. Contact HVD for C coil applications. Explosion roof Solenoid Ratings* U.L. & CS (EU) Class I, Div 1 & 2, Groups C & D Class II, Div 1 & 2, Groups E, F & G s defined by the N.E.C. MSH (EO) Complies with 30CFR, art 18 EX (ED) EX & CS/US (E) Complies with EX requirements for: Exd, Group II; EN50014: 1999+ mds. 1 & 2, EN50018: 2000 Complies with EX EN60079-0, EN60079-1 Ex d IIC; CS/US Ex d IIC, Ex d IIC for Class I, Zone 1, UL1203, UL1604, CS E61241,1 Class II, Div 1 * llowable Voltage Deviation ±10%. Note that Explosion roof C coils are single frequency only. LH Voltage In Rush mps In Rush Holding mps Watts Resistance Voltage ower mperage V @ 3MM D L 120 VDC N/ N/ 0.09 mps 10 W 1584.00 ohms D Omit 120 VDC N/ N/ 0.26 mps 30 W 528.00 ohms G Omit 198 VDC N/ N/ 0.15 mps 30 W 1306.80 ohms J L 24 VDC N/ N/ 0.44 mps 10 W 51.89 ohms J Omit 24 VDC N/ N/ 1.32 mps 30 W 17.27 ohms K L 12 VDC N/ N/ 0.88 mps 10 W 12.97 ohms K Omit 12 VDC N/ N/ 2.64 mps 30 W 4.32 ohms L L 6 VDC N/ N/ 1.67 mps 10 W 3.59 ohms L Omit 6 VDC N/ N/ 5.00 mps 30 W 1.20 ohms Q Omit 100 VC / 60 Hz 2.05 mps 170 V 0.77 mps 30 W 19.24 ohms QD F 100 VC / 60 Hz 1.35 mps 135 V 0.41 mps 18 W 31.20 ohms QD F 100 VC / 50 Hz 1.50 mps 150 V 0.57 mps 24 W 31.20 ohms R F 24/60 VC, Low Watt 6.67 mps 160 V 2.20 mps 23 W 1.52 ohms Omit 240/60 VC 0.83 mps 199 V 0.30 mps 30 W 120.40 ohms Omit 220/50 VC 0.87 mps 191 V 0.34 mps 30 W 120.40 ohms F 240/60 VC, Low Watt 0.70 mps 168 V 0.22 mps 21 W 145.00 ohms F 220/50 VC, Low Watt 0.75 mps 165 V 0.26 mps 23 W 145.00 ohms U L 98 VDC N/ N/ 0.10 mps 10 W 960.00 ohms U Omit 98 VDC N/ N/ 0.31 mps 30W 288.00 ohms Y Omit 120/60 VC 1.7 mps 204 V 0.60 mps 30 W 28.20 ohms Y Omit 110/50 VC 1.7 mps 187 V 0.68 mps 30 W 28.20 ohms Y F 120/60 VC, Low Watt 1.40 mps 168 V 0.42 mps 21 W 36.50 ohms Y F 110/50 VC, Low Watt 1.50 mps 165 V 0.50 mps 23 W 36.50 ohms Z L 250 VDC N/ N/ 0.04 mps 10 W 6875.00 ohms Z Omit 250 VDC N/ N/ 0.13 mps 30 W 1889.64 ohms Explosion roof Solenoids R 24/60 VC 7.63 mps 183 V 2.85 mps 27 W 1.99 ohms 240/60 VC 0.76 mps 183 V 0.29 mps 27 W 1.34 ohms N 220/50 VC 0.77 mps 169 V 0.31 mps 27 W 1.38 ohms Y 120/60 VC 1.60 mps 192 V 0.58 mps 27 W 33.50 ohms 110/50 VC 1.47 mps 162 V 0.57 mps 27 W 34.70 ohms K 12 VDC N/ N/ 2.75 mps 33 W 4.36 ohms J 24 VDC N/ N/ 1.38 mps 33 W 17.33 ohms "E" Explosion roof Solenoids K 12 VDC N/ N/ 1.00 mps 12 W 12.00 ohms J 24 VDC N/ N/ 1.00 mps 13 W 44.30 ohms Y 120/60-50 VC N/ N/ 0.16 mps 17 W 667.00 ohms 84 Elyria, Ohio, US

Dimensions Inch equivalents for millimeter dimensions are shown in (**) Conduit ox, Double C Solenoid LH Note: 30.0mm (1.18") from bottom of bolt hole counterbore to bottom of valve. Conduit ox and Stroke djust, Double C Solenoid Note: 30.0mm (1.18") from bottom of bolt hole counterbore to bottom of valve. 85 Elyria, Ohio, US

Dimensions Inch equivalents for millimeter dimensions are shown in (**) Conduit ox and ilot Choke Control, Double C Solenoid LH Note: 30.0mm (1.18") from bottom of bolt hole counterbore to bottom of valve. Conduit ox, Single C Solenoid Note: 30.0mm (1.18") from bottom of bolt hole counterbore to bottom of valve. 86 Elyria, Ohio, US

Dimensions Inch equivalents for millimeter dimensions are shown in (**) Hirschmann and Stroke djust, Double DC Solenoid LH Note: 30.0mm (1.18") from bottom of bolt hole counterbore to bottom of valve. Hirschmann and ilot Choke Control, Double DC Solenoid Note: 30.0mm (1.18") from bottom of bolt hole counterbore to bottom of valve. 87 Elyria, Ohio, US

Dimensions Inch equivalents for millimeter dimensions are shown in (**) Explosion roof U.L. and C.S.. pproved, Double Solenoid LH hase Out 88 Elyria, Ohio, US

Dimensions Inch equivalents for millimeter dimensions are shown in (**) Explosion roof, EX d IIC EX/CS Single Solenoid LH Explosion roof, EEXD EX, Single Solenoid 130.5 (5.14) 162.5 (6.40) M20x1.5-6H hd. Ground Stud with Lock Washer 74.7 (2.94) 69.9 (2.75) 34.9 (1.38) 214.7 (8.46) 183.9 (7.25) 73.5 (2.90) 125.8 (4.96) 83.0 (3.27) 62.0 (2.44) 224.4 (8.84) 36.0 (1.42) 35.0 (1.38) 70.0 (2.76) 89 Elyria, Ohio, US

Dimensions Inch equivalents for millimeter dimensions are shown in (**) lug-in Conduit ox, Double DC Solenoid LH lug-in Conduit ox, Single DC Solenoid 90 Elyria, Ohio, US

Dimensions Inch equivalents for millimeter dimensions are shown in (**) lug-in Conduit ox, Double DC Solenoid with Variation I3 (Monitor Switch) Double Solenoid. With solenoid energized, flow path is and. When solenoid is energized, flow path is and. he center condition on a spring-centered valve exists when both coils are de-energized, or during a complete shift, as the spool passes through center. LH Monitor Switch (Variation I3 and I6) his feature provides for electrical confirmation of the spool shift. his can be used in safety circuits, to assure proper sequencing, etc. Switch Data in 1 and in 3 have outputs equal to the input. When the monitor switch has the output to in 1, in 3 will have an output of zero, and vice-versa. When the valve is switched, in 1 and in 3 will switch outputs. IN 2 Input 18-42 VDC osition Control Switch Sensor / Driver Circuitry Load 0.2 Max IN 1 IN 3 Outputs 91 Elyria, Ohio, US

ccessories Manaplug (Options 6, 56, 1 & 1C) Interface rad Harrison lug 3-in for Single Solenoid 5-in for Double Solenoid Micro Connector Options (7, 7, 1 & 1D) LH Ground Wire #1 (Green) Solenoid (Negative) Wire #3 (Red/lack) Solenoid (ositive) Wire #2 (Red/White) 3-in Manaplug (Mini) with Lights Single Solenoid Valves Installed Opposite Side of Solenoid ins are as seen on valve (male pin connectors) Manaplug Electrical Mini lug E336-30 E316-30 E31-30 3 in lug 5 in lug (Double Solenoid) 5 in lug (Single Solenoid) Conduit ox Option C No Wiring Options vailable Manaplug Electrical Micro lug E337-30 E317-30 E31-30 3 in lug 5 in lug (Double Solenoid) 5 in lug (Single Solenoid) Signal Lights (Option 5) lug-in Only LED Interface Meets Nema 4/I67 Hirschmann lug with Lights (Option 5) ISO 4400/DIN 43650 Form in #2 (ositive) Face View of lug in #3 (Ground) in #1 (Negative) DESIN Connector (Option D) M12 pin assignment Standard 1 = Not used 2 = Not used 3 = 0V 4 = Signal (24 V) 5 = Earth Ground ins are as seen on valve (male pin connectors) 1 4 2 DESIN design in 1 and 2 connected 5 3 1 2 3 4 5 92 Elyria, Ohio, US