Operation. D1VW Solenoid Operated Plug-In Conduit Box Style

Similar documents
Directional Control Valves Series D81V. General Description. Operation. Features. Specifications

Directional Control Valves. General Description. Operation. Features

Directional Control Valves. Features. Application. Operation

Operation. D1VW Solenoid Operated Plug-In Conduit Box Style

Operation. D1VW Solenoid Operated Plug-In Conduit Box Style

Directional Control Valves

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Directional Control Valves. Application. Features. Operation.

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Directional Control Valves. Application. Features. Operation. D3W Solenoid Operated Conduit Cavity Style. D3W Solenoid Operated Hirschmann (DIN) Style

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Directional Control Valves. Application. Features. Operation

Directional Control Valves. General Description. Operation. Features

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Directional Control Valves. General Description. Operation. Features

Directional Control Valves. Application. Features. Operation

Directional Control Valves. General Description. Features. Specifications

Directional Control Valves. Features. Application. Operation

Directional Control Valves. Features. Application. Operation

Série D3 Válvula Direcional CETOP 5 e NG 10. Catálogo HY /US

Operation. D3W Solenoid Operated Conduit Box Style. D3W Solenoid Operated Hirschmann (DIN) Style

Directional Control Valves Series D111VW. General Description. Features. Performance Curves

Hydraulics 1. Directional Control Valves Series D1M. Features. Application. Operation. D1MW Solenoid Operated Free Lead Wire

Bulletin HY M6/US Service Bulletin. Series D1VW, H Style 91 Design. Effective: May 1, Directional Control Valves

Bulletin HY M2/US Service Bulletin. Series D1VW, C Style 91 Design. Effective: May 1, Directional Control Valves

Directional Controls

Directional Control Valves. General Description. Features. Specifications

Bankable Control Valves

Directional Controls

Direct Operated Proportional DC Valves

Chapter 2: Directional Control Valves

Manapak Sandwich Valves. General Description

High Pressure, Subplate Mounted Directional Control Valves

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

Directional Control Valve Series D1VW

High Pressure, Subplate Mounted Directional Control Valves

Pilot-Operated Directional Control Valves Series D3 - D11

Pilot Operated Directional Control Valves Series D31DW, D41VW - D111VW

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

Directional Control Valve

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

EManually Operated Directional Valves

Directional Controls

Directional Control Valve Series 4D01 (DENISON)

Pressure Control Valves Series R. General Description. Specifications. Flow Data

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

Pilot Operated Directional Valves

Bar 35 PSI 500. Pressure Drop L/M GPM. Flow

DFE10. solenoid control monoblock valve. Ordering codes. Description example : Diverter valve DFE10/3 A 18 ES - W VDC - SAE - <CVN>

Solenoid Valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) A-1.

Pilot Operated Directional Control Valves Series D31DW, D31NW, D*1VW

High Response Type Proportional Electro-Hydraulic Directional and Flow Control Valves

4/2- and 4/3-Way Proportional Directional Control Valve Direct Operated, Model 4 WRA (Series 1X) PSI (315 bar) H/A 1768

Monobloc and Sectional Directional Control Valves

EManually Operated Directional Valves

VSD10M DIRECTIONAL CONTROL VALVES SOLENOID ACTUATED, PILOT OPERATED

VQ1000. How to Order Manifold. Kit type

Series Shockless Type Solenoid Controlled Pilot Operated Directional Valves

Monobloc and Sectional Directional Control Valves

Directional Controls

Directional Control Valve Series D3W Soft Shift

Directional Control Valves

Solenoid valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm)

Monobloc and Sectional Directional Control Valves

ANTI-SHOCK DIRECTIONAL CONTROL VALVES

D03 FluiDyne Valves. ENGINEERING DATA

Directional Control Valves

EMechanically Operated Directional Valves

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

D07 & D08. Series 35 Solenoid Valves D07 D Friendship Drive, Magnolia, TX Tel.: Fax:

Cable Appendix. Valves. Cable Appendix. Page 16. Multi-way cables. D-sub Connector Cables. AXT100-DS Conforming to MIL-C-24308

I N D E X. VQ1000 How to Order, Manifold Options VQ2000 How to Order, Manifold Options VQ1000/2000 Model, Standard/Manifold Specifications

Directional Control Valve Series D3W (Parker), 4D02 (Denison)

"G" SERIES SHOCKLESS TYPE SOLENOID OPERATED DIRECTIONAL VALVES G-DSG-01/03 (1/8, 3/8) "G" SERIES SHOCKLESS TYPE

Pilot Operated Directional Valves

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

Accessories. Subplates and Connection Plates for Four-Port Directional Valves. Vickers. ISO 4401, 02/03/05/07/08 General Description.

Directional Controls

RA / Accumulator unloading valve, pilot operated, Model DA 6 V.., series 4X. Ordering details DA 6 V 4X. Preferred models 1/8.

SECTION TITLE HEC2003/2004 SERIES SERVO VALVE SYSTEM ACCESSORIES KEY FEATURES

Directional control valves NG6...NG32 D03...D10 6

RA / /3, 4/2 and 3/2-Way Directional Valves Model.WE 10.../.D, Series 3X with Wet Pin DC Solenoids. Functional description, section

Monobloc and Sectional Directional Control Valves

NG06. General Size NG6 NG10 Design

3/2 and 4/2 directional poppet valve with solenoid actuation

S21 Series. - 1" NPT - Brass Body - 2-Way Piloted Diaphragm - Normally Open. Dimensions/Weight

3/2 and 4/2 directional seat valves with solenoid actuation

Introduction. Pressure drops

MDT. Monoblock directional control valves MDT - Directional control valve

4/3 and 4/2 on-off directional valve elements D8_5 with or (EDD-XZ) without secondary relief valves and with or without LS connections D8_5 (EDD-XZ)

385 & 962 Series The lectroaire valve is a compact, air operated, electrically lectroaire valves can be remotely mounted for control of double acting

S21 Series. - 2" NPT - Brass Body - 2-Way Piloted Diaphragm - Normally Open. Dimensions/Weight

Sc h rader Bellows. CS Series Air Control Valves. 2 & 3-Way, Inline, Manifold & Stacking Direct Acting Solenoid Valves

Cartridge Valves Technical Information Directional Valves DCV 03

ISO Standard Solenoid Valve. Series VQ7-6/7-8. (Size 1) (Size 2) Conforms to ISO Standard 5599/I

BST / BSG-03 / 06 / 10 Threaded Connections / Sub-plate Mounting. Specifications / Model Number Designation. Max. Flow L/min (U.S.GPM) Double Sol.

5 Port Solenoid Valve: Base Mounted Metal Seal/Rubber Seal. High speed & Long life. (Metal seal, with light and surge suppressor) 100 million cycles

Large Electronically Adjustable Proportional Pressure Compensated Flow Control Engineering & Manufacturing Solutions

4/3-4/2 Directional valve elements with or without secondary relief valves, and with or without LS connections

DFE. solenoid control monoblock valve. Content. Working conditions Hydraulic circuit DFE052. Dimensional data Ordering codes...

Transcription:

Introduction pplication hydraulic directional control valves are high performance, direct operated 4-way valves. hey are available in 2 or 3-position styles. hey are manifold mounted valves, which conform to NF s D03, CEO 3 mounting pattern. hese valves were designed for industrial and mobile hydraulic applications which require high cycle rates, long life and high efficiency. Operation directional control valves consist of a 4-chamber style body, and a case hardened sliding spool. he spool is directly shifted by a variety of operators including: solenoid, lever, cam, air or oil pilots. LH D1VW Solenoid Operated lug-in Conduit ox Style Easy access mounting bolts. Waterproof NEM 4, I67. No tools required for coil removal. 19 standard spool styles available. Four electrical connection options. Lights included (CS approval for DC solenoids and lights). Easy coil replacement. lug-in design offered with lights & other options. D1VW Solenoid Operated Hirschmann (DIN) Style DIN Style (43650) Hirschmann. 19 spool styles available. No tools required for coil removal. Easy coil replacement. C & DC lights available. (CS approval for solenoids and lights). D1V Oil ilot Operated Subplate pilot or end cap pilot option. ilot pressure: 15.2 ar (220 SI) to 207 ar (3000 SI). 2 Elyria, Ohio, US

Introduction Electrical Connections valves may be configured in all popular electrical configurations including: lug-in Conduit ox DESIN (DC only) Deutsch (DC only) Explosion roof Hirschmann (DIN) Metri-ack (DC only) Dual Spade (DC only) Wire Lead Conduit ox LH D1VW Solenoid Operated Wire Lead Conduit ox Style Easy access mounting bolts. Waterproof NEM 4, I67. No tools required for coil removal. 19 spool styles available. No lights available D1VW Solenoid Operated DESIN Style Surge suppression standard. 19 standard spool available. No tools required for spool removal. Easy coil replacement. Wired to DESIN Spec (VDM). Lights included. D1VW Solenoid Operated Dual Spade Style Dual spade connection (SE Style 1). Easy coil replacement. Surge suppression available. 19 standard spool styles available. 3 Elyria, Ohio, US

Introduction Features Easy access mounting bolts. 345 ar (5000 SI) pressure rating. Flows to 22 GM depending on spool. Choice of five operator styles. Rugged four land spools. Low pressure drop. hosphate finished body. CS approved and U.L. recognized available. Optional proportional spool available. Optional painted body. LH D1VL Lever Operated Spring return or detent styles available. Heavy duty handle design. D1V ir Operated Low pilot pressure required 4.1 ar (60 SI) minimum. D1VC Cam Operated Choice of 2 cam roller positions (D1VC and D1VD). wo styles available (D1VC and D1VG). Short stroke option. 4 Elyria, Ohio, US

Introduction D1VW C Solenoid Operated Soft Shift LH 4 standard orifice sizes available. 19 spool styles available. C Rectified or DC input. D1VW DC Solenoid Operated Soft Shift 5 Elyria, Ohio, US

echnical Information Standard Spool Reference Data Maximum Flow, LM (GM) 350 ar (5000 SI) w/o Malfunction High Watt Low Watt Low Watt Model Spool Symbol DC C DC D1V*001 78 (20) 49 (13) 37 (10) D1V*002 78 (20) 45 (12) 68 (18) D1V*003 70 (18) 30 (8) 34 (9) D1V*004 37 (10) 30 (8) 68 (18) D1V*005 60 (16) 45 (12) 45 (12) D1V*006 79 (21) 49 (13) 52 (14) D1V*007 45 (12) 18 (5) 18 (5) D1V*008 49 (13) 45 (12) 37 (10) D1V*009 58 (15) 45 (12) 45 (12) D1V*010 13 (4) 11 (3) 15 (4) D1V*011 58 (16) 30 (8) 37 (10) D1V*014 45 (12) 18 (5) 18 (5) D1V*015 79 (21) 30 (8) 34 (9) D1V*016 60 (16) 45 (12) 52 (14) D1V*020 78 (20) 45 (12) 75 (20) D1V*026 37 (10) 11 (3) 7 (2) D1V*030 70 (18) 18 (5) 75 (20) D1V*081 32 (9) 26 (7) 30 (8) D1V*082 32 (9) 26 (7) 34 (9) Center or De-energized position is indicated by,, & port notation. LH 6 Elyria, Ohio, US

echnical Information D1V, D1V, D1VC, D1VL Reference Data Maximum Flow, LM (GM) 350 ar (5000 SI) Model Spool Symbol w/o Malfunction D1V*1 83 (22) D1V*2 83 (22) D1V*4 45 (12) D1V*8 45 (12) D1V*9 57 (15) Center or De-energized position is indicated by,, & port notation. # D1V only. Maximum Flow, LM (GM) 350 ar (5000 SI) Model Spool Symbol w/o Malfunction D1V*20 # 53 (14) D1V*26 # 11 (3) D1V*30 # 19 (5) D1V*81 30 (8) D1V*82 30 (8) LH Manaplug Electrical Mini lug E336-30 3 in lug E316-30 5 in lug (Double Solenoid) E31-30 5 in lug (Single Solenoid) Manaplug Electrical Micro lug E337-30 3 in lug E317-30 5 in lug (Double Solenoid) E31-30 5 in lug (Single Solenoid) Desina 12mm Connector 5004109 Monitor Switch Connector 1301903-N Electrical Cords Mini lug EC EC3 EC12 EC5 EC53 EC512 3 Conductor, 6 ft. 3 Conductor, 3 ft. 3 Conductor, 12 ft. 5 Conductor, 6 ft. 5 Conductor, 3 ft. 5 Conductor, 12 ft. Hirschmann Female Connector 692915 Gray (Solenoid ) 1 1 692914 lack (Solenoid ) 1 1 Hirschmann Female Connector-Rectified (48-240 VC) 1301053 Gray (Solenoid ) 1 1 1301054 lack (Solenoid ) 1 1 Hirschmann Female Connector-Rectified w/lights (100-240 VC) 1300712 2 1 1 Hirschmann Female Connector w/lights (Note Voltages) Quantity Required,C,D,E,F H,K,M 694935 6-48 VC or VDC 2 1 1 694936 48-120 VDC, 100-240 VC 2 1 1 7 Elyria, Ohio, US

echnical Information Solenoid Ratings Insulation System Class F llowable Deviation -15% to +10% for DC and C rectified coils from rated voltage -5% to +5% for C Coils rmature CS File Number Environmental Capability Wet pin type LR60407 DC Solenoids meet NEM 4 and I67 when properly wired and installed. Contact HVD for C coil applications. Explosion roof Solenoid Ratings* U.L. & CS (EU) Class I, Div 1 & 2, Groups C & D Class II, Div 1 & 2, Groups E, F & G s defined by the N.E.C. MSH (EO) Complies with 30CFR, art 18 EX (ED) EX & CS/US (E) Complies with EX requirements for: Exd, Group II; EN50014: 1999+ mds. 1 & 2, EN50018: 2000 Complies with EX EN60079-0, EN60079-1 Ex d IIC; CS/US Ex d IIC, Ex d IIC for Class I, Zone 1, UL1203, UL1604, CS E61241,1 Class II, Div 1 * llowable Voltage Deviation ±10%. Note that Explosion roof C coils are single frequency only. LH Code Voltage In Rush mps In Rush Holding mps Watts Resistance Voltage ower mperage V @ 3MM Code Code D L 120 VDC N/ N/ 0.09 mps 10 W 1584.00 ohms D Omit 120 VDC N/ N/ 0.26 mps 30 W 528.00 ohms G Omit 198 VDC N/ N/ 0.15 mps 30 W 1306.80 ohms J L 24 VDC N/ N/ 0.44 mps 10 W 51.89 ohms J Omit 24 VDC N/ N/ 1.32 mps 30 W 17.27 ohms K L 12 VDC N/ N/ 0.88 mps 10 W 12.97 ohms K Omit 12 VDC N/ N/ 2.64 mps 30 W 4.32 ohms L L 6 VDC N/ N/ 1.67 mps 10 W 3.59 ohms L Omit 6 VDC N/ N/ 5.00 mps 30 W 1.20 ohms Q Omit 100 VC / 60 Hz 2.05 mps 170 V 0.77 mps 30 W 19.24 ohms QD F 100 VC / 60 Hz 1.35 mps 135 V 0.41 mps 18 W 31.20 ohms QD F 100 VC / 50 Hz 1.50 mps 150 V 0.57 mps 24 W 31.20 ohms R F 24/60 VC, Low Watt 6.67 mps 160 V 2.20 mps 23 W 1.52 ohms Omit 240/60 VC 0.83 mps 199 V 0.30 mps 30 W 120.40 ohms Omit 220/50 VC 0.87 mps 191 V 0.34 mps 30 W 120.40 ohms F 240/60 VC, Low Watt 0.70 mps 168 V 0.22 mps 21 W 145.00 ohms F 220/50 VC, Low Watt 0.75 mps 165 V 0.26 mps 23 W 145.00 ohms U L 98 VDC N/ N/ 0.10 mps 10 W 960.00 ohms U Omit 98 VDC N/ N/ 0.31 mps 30W 288.00 ohms Y Omit 120/60 VC 1.7 mps 204 V 0.60 mps 30 W 28.20 ohms Y Omit 110/50 VC 1.7 mps 187 V 0.68 mps 30 W 28.20 ohms Y F 120/60 VC, Low Watt 1.40 mps 168 V 0.42 mps 21 W 36.50 ohms Y F 110/50 VC, Low Watt 1.50 mps 165 V 0.50 mps 23 W 36.50 ohms Z L 250 VDC N/ N/ 0.04 mps 10 W 6875.00 ohms Z Omit 250 VDC N/ N/ 0.13 mps 30 W 1889.64 ohms Explosion roof Solenoids R 24/60 VC 7.63 mps 183 V 2.85 mps 27 W 1.99 ohms 240/60 VC 0.76 mps 183 V 0.29 mps 27 W 1.34 ohms N 220/50 VC 0.77 mps 169 V 0.31 mps 27 W 1.38 ohms Y 120/60 VC 1.60 mps 192 V 0.58 mps 27 W 33.50 ohms 110/50 VC 1.47 mps 162 V 0.57 mps 27 W 34.70 ohms K 12 VDC N/ N/ 2.75 mps 33 W 4.36 ohms J 24 VDC N/ N/ 1.38 mps 33 W 17.33 ohms "E" Explosion roof Solenoids K 12 VDC N/ N/ 1.00 mps 12 W 12.00 ohms J 24 VDC N/ N/ 1.00 mps 13 W 44.30 ohms Y 120/60-50 VC N/ N/ 0.16 mps 17 W 667.00 ohms 8 Elyria, Ohio, US

erformance Curves D1V Shift Limits, DC & C Rectified 30 Watt LH Example: Determine the maximum allowable flow of a Series D1V valve (#004 spool) at 138 ar (2000 SI) supply pressure. Locate the curve marked 004. t 138 ar (2000 SI) supply pressure, the maximum flow is 57 LM (15 GM). t 207 ar (3000 SI), the flow is 49 LM (13 GM). D1VW*****L Shift Limits Important Notes for Switching Limit Charts 1. For F & M style valves, reduce flow to 70% of that shown. 2. Shift limits charted for equal flow and ports. Unequal and port flows may reduce shift limits. 3. hese charts do not show explosion proof performance. Consult factory for explosion proof duty. 4. locking or ports will reduce flow by 70%. 9 Elyria, Ohio, US

erformance Curves D1V Shift Limits, DC & C Rectified 30 Watt LH Example: Determine the maximum allowable flow of a Series D1V valve (#008 spool) at 83 ar (1200 SI) supply pressure. Locate the curve marked 008. t 83 ar (1200 SI) supply pressure, the maximum flow is 57 LM (15 GM). t 207 ar (3000 SI), the flow is 19 LM (5 GM). D1VW*****L Shift Limits Important Notes for Switching Limit Charts 1. For F & M style valves, reduce flow to 70% of that shown. 2. Shift limits charted for equal flow and ports. Unequal and port flows may reduce shift limits. 3. hese charts do not show explosion proof performance. Consult factory for explosion proof duty. 4. locking or ports will reduce flow by 70%. 10 Elyria, Ohio, US

erformance Curves D1V Shift Limits, DC & C Rectified 30 Watt LH Example: Determine the maximum allowable flow of a Series D1V valve (#081 spool) at 83 ar (1200 SI) supply pressure. Locate the curve marked 081. t 83 ar (1200 SI) supply pressure, the maximum flow is 42 LM (11 GM). t 138 ar (2000 SI), the flow is 42 LM (11 GM). D1VW*****L Shift Limits Important Notes for Switching Limit Charts 1. For F & M style valves, reduce flow to 70% of that shown. 2. Shift limits charted for equal flow and ports. Unequal and port flows may reduce shift limits. 3. hese charts do not show explosion proof performance. Consult factory for explosion proof duty. 4. locking or ports will reduce flow by 70%. 11 Elyria, Ohio, US

erformance Curves D1V Shift Limits, C 30 Watt Supply ressure SI ar 5000 345 300 4000 250 010,026 3000 200 150 2000 030 021,022 007,014 003,004, 011,015 081,082 008 009 006 001,002 LH 100 005,016,020 1000 50 0 L/M 0 GM 10 20 30 40 50 60 70 80 83 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Flow 12 Elyria, Ohio, US

erformance Curves D1VW*****F Shift Limits, C LH Example: Determine the maximum allowable flow of a Series D1V valve (#009 spool) at 83 ar (1200 SI) supply pressure. Locate the curve marked 009. t 83 ar (1200 SI) supply pressure, the maximum flow is 75 LM (20 GM). t 207 ar (3000 SI), the flow is 68 LM (18 GM). Soft Shift Limit Curves DC ower Supply Important Notes for Switching Limit Charts 1. For F & M style valves, reduce flow to 70% of that shown. 2. Shift limits charted for equal flow and ports. Unequal and port flows may reduce shift limits. 3. hese charts do not show explosion proof performance. Consult factory for explosion proof duty. 4. locking or ports will reduce flow by 70%. 13 Elyria, Ohio, US

echnical Information ressure Drop vs. Flow, High Watt he table to the right provides the flow vs. pressure drop curve reference for standard and high performance D1V Series valves by spool type. he chart below demonstrates graphically the pressure drop characteristics of the standard D1VW*****F and the high performance D1V. he low watt coil and other design features of the standard D1VW*****F accommodate a maximum flow of 50 LM (13 GM) at 345 ar (5000 SI). D1VW ressure Drop Reference Chart 30 Watt Coil Curve Number Spool Shifted Center Condition No. ( ) ( ) ( ) (-) (-) (-) (-) 001 3 3 2 2 002 2 2 1 1 2 1 1 1 1 1 1 003 2 2 1 1 1 004 2 2 1 1 2 2 005 2 3 1 1 5 006 2 2 1 1 6 6 6 6 007 2 3 1 1 4 1 008 5 5 5 5 5 009 4 4 4 4 4 010 3 3 011 3 3 1 1 8 8 014 3 2 1 1 4 1 015 2 2 1 1 1 016 3 2 1 1 5 020 4 4 2 2 026 4 4 030 2 2 1 1 081 7 7 8 8 082 7 7 8 8 LH Viscosity Correction Factor Viscosity 75 150 200 250 300 350 400 (SSU) % of 93 111 119 126 132 137 141 (pprox.) Curves were generated using 100 SSU hydraulic oil. For any other viscosity, pressure drop will change per chart. ressure drops charted for equal flow and ports. Unequal and port flows may decrease shift limits. erformance Curves 30 Watt Coil 14 Elyria, Ohio, US

echnical Information ressure Drop vs. Flow, Low Watt he table to the right provides the flow vs. pressure drop curve reference for 10 watt D1V Series valves by spool type. he chart below demonstrates graphically the pressure drop characteristics of the standard D1VW*****L and the high performance D1V. he low watt coil and other design features of the standard D1VW*****L accommodate a maximum flow of 50 LM (13 GM) at 345 ar (5000 SI). D1VW ressure Drop Reference Chart 10 Watt Coil Curve Number Spool Shifted Center Condition No. ( ) ( ) ( ) (-) (-) (-) (-) 001 3 3 2 2 002 2 2 1 1 2 2 2 2 2 1 1 003 3 3 2 1 4 004 3 3 1 1 6 6 005 3 3 1 1 7 006 3 3 1 1 8 8 7 7 007 3 3 1 1 5 4 1 008 5 5 6 6 7 009 6 6 6 6 5 010 4 4 011 3 3 1 1 11 11 014 3 3 1 1 4 2 1 015 3 3 1 2 4 016 3 3 1 1 7 020 7 7 4 4 026 6 6 030 2 2 1 1 081 9 9 10 10 082 10 10 10 10 LH Viscosity Correction Factor Viscosity 75 150 200 250 300 350 400 (SSU) % of 93 111 119 126 132 137 141 (pprox.) Curves were generated using 100 SSU hydraulic oil. For any other viscosity, pressure drop will change per chart. erformance Curves 10 Watt Coil 15 Elyria, Ohio, US

Notes LH 16 Elyria, Ohio, US

echnical Information General Description W directional control valves are high performance, 4-chamber, direct operated, wet armature solenoid controlled, 3 or 4-way valves. hey are available in 2 or 3-position and conform to NF s D03, CEO 3 mounting patterns. W LH Features Soft shift available. 19 standard spool styles available (for other spools Consult Factory). roportional spools. DC surge suppression. Eight electrical connection options. C & DC lights available (CS approval for solenoids and lights). Internally ground. Easy access mounting bolts. Waterproof (meets NEM 4, up to I67 on some models). Explosion proof. CS approvals. Specifications Mounting attern NF D03, CEO 3, NG 6 Mounting DIN 24340-6 Interface ISO 4401--03-4- CEO R35H 4.2-4-03, NF D03 Maximum,, ressure 345 ar (5000 SI) Standard 207 ar (3000 SI) 10 Watt CS 276 ar (3750 SI) ank: 103 ar (1500 SI) C only 207 ar (3000 SI) DC/C Rectified Standard 207 ar (3000 SI) C Optional CS 103 ar (1500 SI) U.L. recognized available - Contact the division. No tools required for coil removal. C rectified coils. Leakage Rates* Maximum llowable: 100 SSU @ 19.7 cc (1.2 Cu. in.) per Minute/Land @ 49 C (120 F) 69 ar (1000 SI)* 73.8 cc (4.5 Cu. in.) per Minute/Land @ 207 ar (3000 SI)* *#008 and #009 ypical: Spools may 4.9 cc (0.3 Cu. in.) per Minute/Land @ exceed these rates. 69 ar (1000 SI)* Consult Factory 26.2 cc (1.6 Cu. in.) per Minute/Land @ 345 ar (5000 SI) Response ime Response time (milliseconds) at 345 ar (5000 SI) is 32 LM (8.5 GM). Solenoid ype ull-in Drop-Out C 13 20 DC 10 Watt 61 22 DC 30 Watt 51 21 Spool Center Condition Orifice Closed Open 2-osition Soft Shift Size Energize De-Energize Energize De-Energize Energize De-Energize S2 0.020 125 ms 920 ms 200 ms 275 ms 51 ms 100 ms S5 0.050 51 ms 675 ms 50 ms 27 ms 51 ms 21 ms 17 Elyria, Ohio, US

Ordering Information D Directional Control Valve 1V NF D03 CEO 3 DIN NG6 Code N V asic Valve ctuator Spool Style Seal Solenoid Voltage Code Description W* Solenoid, Wet in, Screw-in HW* Reversed Wiring * Valve schematic symbols are per NF/ NSI standards, providing flow to when energizing solenoid. Note operators reverse sides for #008 and #009 spools. See installation information for details. o configure per DIN standards ( coil over port, coil over port) code valves as D1VHW***. Description Nitrile E* ER Fluorocarbon * Contact HVD for availability. Code Description ** 24/50 VC D G J K L 120 VDC 198 VDC 24 VDC 12 VDC 6 VDC N*** 220/50 VC *** 110/50 VC ** High Watt only *** Explosion roof only. vailable in DIN only. Code Description Q** 100/60 VC QD 100/60-100/50 VC R U Y Z 24/60 VC 240/60-220/50 VC 98 VDC 120/60-110/50 VC 250 VDC LH Code Symbol Code Symbol 001 011 Code Description Symbol * Single solenoid, 2 position, spring offset. to and to in offset position. b 002 014 003 015 004 016 005 020* 006 026* 007 030** 008*, 081 009** 010 082 * 008, 020 & 026 spools have closed crossover. ** 009 & 030 spools have open crossover. C D E F Double solenoid, 3 position, spring centered. Double solenoid, 2 position, detent. Single solenoid, 2 position, spring centered. to and to when energized. Single solenoid, 2 position. Spring offset, energized to center. osition spool spacer on side. to and to in spring offset position. H* Single solenoid, 2 position, spring offset. to and to in offset position. K M Single solenoid, 2 position, spring centered. to and to when energized. Single solenoid, 2 position, spring offset, energized to center position. Spool spacer on side. to and to in spring offset position. * 020, 026 and 030 spools only. 020 and 030 spools only. High Watt only. b b b b a a a a a old: Designates ier I products and options. Non-old: Designates ier II products and options. hese products will have longer lead times. 18 Elyria, Ohio, US

Ordering Information Code Solenoid Connection Description C* Leadwire Conduit ox D** Metric lug (M12X1), DESIN E Explosion roof G lug-in Conduit ox J# Deutsch (D06-2S) M# Metri-ack (150) DIN with lug S# Dual Spade W DIN w/o lug * No variations See lug-in. ** DC only, lights, diode surge suppressor, not CS approved. Not available with lights. Required for variations on conduit box style. Must have lights. # DC only, no lights, not CS approved. Code Omit* D** E** Description High Watt Explosion roof, EEXD EX Explosion roof, EEXME EX F Low Watt L O** 10 Watt Explosion roof, MSH # Explosion roof, Ex d IIC EX/CS U ** Explosion roof, UL/CS Coil Options * C ambient temperature must not exceed 60 C (140 F). ** 60 Hz only on C, no options. C only. DC and C rectified only. # J, K and Y voltages only. Dual frequency on C, no options. Valve Weight: Single Solenoid 1.36 kg (3.0 lbs.) Double Solenoid 1.6 kg (3.5 lbs.) Standard olt Kit: K209 Metric olt Kit: KM209 Seal Kit: Nitrile SKD1VWN91 Fluorocarbon SKD1VWV91 ube Options Code Omit Manual Override Options Code Omit * Code Omit J** Description Standard No Override * Extended Manual Override w/oot * Manual override options not available on explosion proof or soft shift. DC/C rectified only. Description Standard ressure 103.5 ar (1500 SI) C 207 ar (3000 SI) DC H* High ressure, C only 207 ar (3000 SI) * Not available with CS. Electrical Options Code Omit Description No Options Diode Surge Suppressor Z Rectified Coil DC tube standard. ** DC only. DIN coil must have plug with lights. Shift Response and Indication Description Standard Response S2* Soft Shift, 0.020" Orifice S3* Soft Shift, 0.030" Orifice S4* Soft Shift, 0.040" Orifice S5* Soft Shift, 0.050" Orifice I7** I8** Monitor Switch Direct Op. End Stroke Monitor Switch Direct Op. Start Stroke * Not available with 10 watt. C DIN coil must include plug. ** Single solenoid models only. Not CE or CS approved. Code Omit pprovals Description Standard Valve 3* CS US 4*# CS Canada * Not available with C high pressure tube., C, H styles only. J, K, Y, U voltages only. C, G, W sol. connections only. Conforms to UL429. # Valve is derated. Code Omit old: Designates ier I products and options. Description No Variations 5** Signal Lights Valve Design Variations Series NOE: Not required when ordering. 56* Manaplug (Mini) with Lights 7* Manaplug (Micro) with Lights 1C* Manaplug (Mini) Single Sol. 5-pin, with Lights 1D* Manplug (Micro) Single Sol. 5-pin, with Lights 1M* Manaplug Opposite of Normal 4D wist & Lock Override (Old 5426, 33 Ford wiring) 4E ush Manual Override (Old x5450) 4F 1 Heavy Duty Detent ainted ody 7Y* 4-pin M12x1 Manaplug, special wiring with lights (Old 755) * lug-in Conduit ox ** lug-in, DIN, or DESIN only DC/C Rectified only. Not available with soft shift. Non-old: Designates ier II products and options. hese products will have longer lead times. LH 19 Elyria, Ohio, US

Dimensions Inch equivalents for millimeter dimensions are shown in (**) DC lug-in Conduit ox Connector, with Lights, Double Solenoid LH Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve. DC lug-in or Leadwire Conduit ox Connector, with or without Lights, Single Solenoid Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve. 20 Elyria, Ohio, US

Dimensions Inch equivalents for millimeter dimensions are shown in (**) DC DIN with lug Connector, Double Solenoid Option Shown LH DC DIN Connector, Single Solenoid Option Shown Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve. Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve. 21 Elyria, Ohio, US

Dimensions Inch equivalents for millimeter dimensions are shown in (**) C Leadwire Conduit ox Connector, without Lights, Double Solenoid, C Option LH Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve. C Leadwire Conduit ox Connector, without Lights, Single Solenoid, C Option Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve. 22 Elyria, Ohio, US

Dimensions Inch equivalents for millimeter dimensions are shown in (**) C lug-in Conduit ox Connector, with Lights, Double Solenoid, G Option LH Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve. DC lug-in or Leadwire Conduit ox Connector, with or without Lights and Extended Override ubes, Double Solenoid Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve. 23 Elyria, Ohio, US

Dimensions Inch equivalents for millimeter dimensions are shown in (**) DC Deutsch Connector, Double Solenoid LH Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve. DC Deutsch Connector, Single Solenoid Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve. 24 Elyria, Ohio, US

Dimensions Inch equivalents for millimeter dimensions are shown in (**) DC Desina Connector, Double Solenoid LH 87.8 (3.46) DC Desina Connector, Single Solenoid Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve. Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve. 25 Elyria, Ohio, US

Dimensions Inch equivalents for millimeter dimensions are shown in (**) Explosion roof, Ex d IIC EX/CS, Double Solenoid LH Explosion roof, Ex d IIC EX/CS, Single Solenoid 26 Elyria, Ohio, US

Dimensions Inch equivalents for millimeter dimensions are shown in (**) Explosion roof U.L. & C.S.., Double Solenoid 1/2" N 130.8 (5.15) 60.4 (2.38) 163.7 (6.44) Explosion roof M.S.H.., Double Solenoid hase Out 304.4 (11.98) Note: 41.0 mm (1.62") from bottom of bolt hole counterbore to bottom of valve. 18 Inch Lead Wires Standard 94.4 (3.72) 46.0 (1.81) 73.0 (2.87) Note: 2 black wires 1 green wire 15.1 (0.61) 7.5 (0.30) LH 3/4-20 UNF hd. 60.4 (2.38) 163.7 (6.44) 3/4-20 UNF hd. 38.0 (1.50) 113.0 (4.45) 130.8 (5.15) 304.4 (6.44) Note: 41.0 mm (1.62") from bottom of bolt hole counterbore to bottom of valve. Explosion roof, EEXD EX, Double Solenoid 46.0 (1.81) 73.0 (2.87) 15.51 (0.61) 7.5 (0.30) 74.7 (2.94) 69.9 (2.75) 19.4 (0.76) 15.5 (0.61) M20 x 1.5-6H hd. Ground Stud with Lockwasher 100.9 (3.97) 42.8 (1.69) 131.7 (5.19) 100.6 (3.96) 7.5 (0.30) 46.0 (1.81) 73.5 (2.89) 141.0 (5.55) 324.7 (12.78) 27 Elyria, Ohio, US

Dimensions Inch equivalents for millimeter dimensions are shown in (**) DC lug-in or Leadwire Conduit ox with Monitor Switch, with or without Lights, Single Solenoid LH Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve. Monitor Switch (Variation I7 and I8) his feature provides for electrical confirmation of the spool shift. his can be used in safety circuits, to assure proper sequencing, etc. Switch Data Inductive switch requiring +18-42 volt input. Outputs and are opposite; one at 0 voltage, the other at input voltage. During switching, and outputs reverse. rovides 0.4 switching current. For repetitive switch power-up conditions, please consult factory. 28 Elyria, Ohio, US

ccessories Manaplug (Options 56 & 1C) Interface rad Harrison lug 3-in for Single Solenoid 5-in for Double Solenoid Ground Wire #1 (Green) Micro Connector Options (7 & 1D) LH Solenoid (Negative) Wire #3 (Red/lack) Solenoid (ositive) Wire #2 (Red/White) 3-in Manaplug (Mini) with Lights Single Solenoid Valves Installed Opposite Side of Solenoid ins are as seen on valve (male pin connectors) Conduit ox Option C No Wiring Options vailable Signal Lights (Option 5) lug-in Only LED Interface Meets Nema 4/I67 Hirschmann lug with Lights (Option 5) DESIN Connector (Option D) ISO 4400/DIN 43650 Form in #2 (ositive) Face View of lug in #3 (Ground) in #1 (Negative) M12 pin assignment Standard 1 = Not used 2 = Not used 3 = 0V 4 = Signal (24 V) 5 = Earth Ground ins are as seen on valve (male pin connectors) 1 4 2 DESIN design in 1 and 2 connected 5 3 1 2 3 4 5 29 Elyria, Ohio, US

ccessories Mounting olt Kits olt Kits for use with D1V, "E" Explosion roof & Sandwich Valves (D1V*-91, 82 & 70/75 Design, Solenoid Operated & D1V*-72 Design, Non-Solenoid Operated) Number of Sandwich Valves at 44.5mm (1.75") hickness Note: 0 1 2 3 4 Number of Sandwich Valves @40mm (1.58") thickness 0 1 2 3 4 K209 1.25 in. K243 2.88 in. K225 4.38 in. K244 6.00 in. K245 7.50 in. KM209 30 mm KM243 70 mm KM225 110 mm KM244 150 mm KM245 190 mm K246 3.00 in. K247 4.62 in. K248 6.12 in. K249 7.75 in. KM246 75 mm KM247 115 mm KM248 155 mm KM249 195 mm K250 4.75 in. K251 6.38 in. K252 7.88 in. KM250 120 mm KM251 160 mm KM252 200 mm K253 6.50 in. K254 8.12 in. KM102 170 mm KM254 205 mm K103 KM103 8.25 in. 210 mm ll bolts are SE Grade 8, 10-24 UNC 2 thread (Metric-M5-0.8) orque to 5.6 Nm (50 in-lb). olt Kits for use with D1V with Explosion roof Coils & Sandwich Valves (D1V*-91, 82 & 70/75 Design) Except "E" Coil LH Number of Sandwich Valves at 44.5mm (1.75") hickness Note: 0 1 2 3 4 Number of Sandwich Valves @40mm (1.58") thickness 0 1 2 3 4 K50 2.00 in. K211 3.63 in. K101 5.12 in. K102 6.75 in. K103 8.25 in. KM50 50 mm KM101 130 mm KM102 170 mm KM103 210 mm K51 3.75 in. K212 5.37 in. K105 6.87 in. K106 7.75 in. KM51 95 mm KM105 180 mm KM106 195 mm K52 5.50 in. K213 7.13 in. K108 8.62 in. KM52 140 mm KM108 220 mm K53 7.25 in. K214 8.87 in. KM53 185 mm K54 KM54 9.00 in. 230 mm ll bolts are SE Grade 8, 10-24 UNC 2 thread (Metric-M5-0.8) orque to 5.6 Nm (50 in-lb). Sandwich Valve Dimensional Data ll D03 Sandwich valves (starting with 31 Series) including CM2, COM2, FM2, RDM2 and RM2 measure 40mm (1.58") thickness. For additional technical information about Sandwich valves, refer to the Sandwich Valve Section of this Catalog. 30 Elyria, Ohio, US