PHASE MASTER NOW IN 4 SIZES

Similar documents
FEATURES. ~ Compression resistant low loss, low density dielectric. ~ Quadraform shielding. ~ Highly reliable soldered connections

DynaFlex series cable assemblies employ innovative designs and material technology to deliver optimized electrical and

Multi-Flex Low Loss, Pre-Connectorized Cable Sets, DC~18 GHz, MF02-Series

ArcTite. single path to optimal performance. Ultra-low profile bends

CABLES FOR AUTOMOTIVE MARKET Sensor and multimedia cables. Catalogue

SMA Male Connector Solder Attachment for RG188-DS, RG316-DS

TELEDYNE STORM MICROWAVE. even in space TELEDYNE. Everywhereyoulook. Tel Fax Toll Free

RP SMA Female Connector Crimp/Solder Attachment For RG178, RG196

LMR-195-LLPX. LMR -195-LLPX Flexible Low Loss Plenum Coax TIMES MICROWAVE SYSTEMS

75 OHM COAXIAL CABLE (RG6)

Esoteric. MEXCEL Cable

MaxFlite high-performance 100 Base-T Ethernet cables

PRODUCT NAME ORDER # PAGE # ANTENNAS

Type P Drilmar 125-XE Signal & Instrumentation

RP SMA Male Connector Crimp/Solder Attachment for RG174, RG316, RG188, PE-B100, PE-C100, inch, LMR-100

fiber optic cable Outdoor Cables

FAKRA Jack Right Angle Connector Crimp/Solder Attachment for RG174, RG316, RG188,.100 inch, PE-B100, PE-C100, LMR-100, White Color

Detailed Specifications & Technical Data

Import Connection. Genuine Intermotor Wire. Beauty s more than skin deep. Genuine Intermotor Import Protection, Fit, and Power.

Interface Mating Dimensions

UNSHIELDED MULTI CONDUCTOR

Data sheet chainflex CF240

Interface Mating Dimensions

SHIELD-FLEX EMI / RFI Shielded Conduit

Standard hook-up wires and cables for Electronics Filotex

Unarmored Variable Frequency Drive (VFD) Cable Termination Guide

Technical data sheet LÜTZE SUPERFLEX PLUS (C) PUR FEEDBACK Encoder cables for Siemens and other systems For highest requirements in drive technology

Type LT Self-Regulating Heater Cable For use in Ordinary (Unclassified) and Hazardous (Classified) Locations

Assembly, Installation, and Removal of Contacts and modules

Control Cable Type P 600/1000 volts DRILMAR 125-XE Crosslinked Polyolefin Insulated Drilling Rig and Marine Cable

ASSEMBLY, INSTALLATION, AND REMOVAL OF CONTACTS AND MODULES

Our Most Important Connection is with You. SECTION 2 SMPM / SMP / SMP-LOCK / SMP-COM R201 / R222 / R222L / R2229

ZHPCG CK0226 POWER CABLE WIRE & CABLE

Product Bulletin. Be Certain with Belden. Belden DataTwist 1200 Cables

U/FTP vs F/UTP CAT6A LAN Cables June 2016

Type LT Self-Regulating Heater Cable For use in Ordinary and Hazardous (Classified) Locations

Coaxial SMA MaleTerminations

Data sheet chainflex CF10

Technical data sheet LÜTZE SUPERFLEX PLUS M (C) PUR SERVO 0.6/1 kv Supply line for Bosch Rexroth and other systems For highest requirements

SHIELD-FLEX EMI / RFI Shielded Conduit

Type P Drilmar 125-XE Signal & Instrumentation

Identification Type SU+M(C)P SE(4G1,5+(2 0,75)+(2 AWG22))UL 1KV OR. Part-No

Caring for cables. Types of installation

Data sheet chainflex CF8821

Amphenol s 2M Micro38999 Connector Series The New Aerospace Standard

Industrial, Heavy Insulated Mono-Tape. and Duo-Tape

Data sheet chainflex CF6

D X X - XX - XX - X X

Control Cable Type T/N 600/1000 volts DRILMAR 90 Polyvinyl Chloride/Nylon Insulated Drilling Rig and Marine Cable

Caledonian Submersible Pump Cables for Oil Industry >> IEEE 1018 >> IEEE 1019 >> API RP 11S5

Gexol. Gexol. World Class Oil & Gas Cables. The Global Cable Solutions Company

Quick Splice II 5451R. 25/28 kv Molded Rubber Cable Repair Splicing Kit Data Sheet. 1. Product Description. 2. Applications

Tender No. : Ref. No. : LSGS-13-CX User / Customer : Page No. : 1 of 9. Specification. For

QTII (X) Series Silicone Rubber Cold Shrink Termination Kits

Metallic Systems TYPE SPTC

Data sheet chainflex CF140.UL

SOFT-SHIELD 5000 Series Conductive Jacket over Foam EMI Gaskets

14 HH EAC/CTP CE RoHS-II conform

For the plastics machinery industry Fixed bayonet thermocouple Model TC47-FB

PPT 802, Proximity Probe Transducer System

Type HLT Self-Regulating Heater Cable For use in Ordinary and Hazardous (Classified) Locations

Data sheet chainflex CF210.UL

VS / 069 / 077 / 079

Introduction. Phone (888) Fax (800) Int l Phone Int l Fax

Interconnect Cable Simplex and Duplex

HVS S 15kV Class

NOZZLE HEATER BANDS. Part No. Standard Metric Watts Volts Quantity Prices

BLINDMATE CONNECTORS AND COMPONENTS. Selection Guide BMA BMMA BMZ BZ

- (90 - f (GHz)) db (.05 SQT(f(GHz))) db

Quick Splice II. 35 kv Molded Rubber Inline Splicing Kit Data Sheet. 2. Applications. 1. Product Description

H e a t s h r i n k P r o d u c t G u i d e

Cheminax RF Coaxial Cables and RF Connectors

ULTROL Still ahead of its time after 30 years Class 1E nuclear rated cable

SMB Amphenol. 50 ohm Coaxial Connectors Specifications 36 Plugs 37 Jacks 38 Bulkhead Receptacles PCB Receptacles 41-43

Mil-Spec Wire and Cable

For the plastics machinery industry Manifold thermocouple Model TC47-MT

Terminations. 3M Cold Shrink Terminations FAX TERMINATIONS. Glossary of Terminations Terms 263 Cable Types for Terminating 264 3M

Product Installation Instructions. Raychem Corporation Electrical Products 8000 Purfoy Road Fuquay-Varina, NC 27526

Conductor: Fine-wire strand consisting of bare copper wires (following DIN EN 60228). Mechanically high-quality TPE mixture. (see colour code table)

Data sheet chainflex CF270.UL.D

Easier! Faster! Safer!

DUCTING: U-01 MATERIAL HANDLING ANTI STATIC CUSTOM MADE DUST FUMES

600/1000 V. 5. Flame Retardancy VDE , DIN EN , IEC

Data sheet CFBUS.PVC PVC - e-chain - Bus cable for medium load requirements (class 4.3.2): shielded, oil-resistant as well as flame-retardant.

Splice Trays. features and benefits. specifications. A LANscape. Solutions Product. Splice Capacity

DNV-GL HH CE RoHS-II conform

Branch Splice QS-2001B

Data sheet chainflex CFSOFT1

RG7H1R-1,8/3 26/45 kv RG7H1OR-1,8/3 18/30 kv

For the plastics machinery industry Adjustable bayonet thermocouple Model TC47-AB

Data sheet chainflex CF886

LBB ULTRA-PRECISION GAGE HEADS

MEDIUM VOLTAGE TERMINATIONS

Table of Contents SMA CONNECTORS

N Male Connector Clamp/Solder Attachment for PE-C600, inch, LMR-600

Proving Installed Performance of Airframe Microwave Assemblies. White Paper

Type P Drilmar 125-XE Power/Distribution Cable Multiconductor

0.6/1KV FLAME RETARDANT UNARMORED CABLE PRODUCT CONSTRUCTION 1. CONDUCTOR CROSS-LINKED POLYETHYLENE (XLPE) IEEE 1580 COLOR CODE 3.

MicroMate (MMCX) Amphenol Specifications

Data sheet chainflex CF340

Transcription:

NOW IN 4 SIZES PHASE MASTER Phase Stable ASSEMBLIES Are you a design or test engineer looking for cable assemblies that offer an unmatched combination of phase stability, low loss, and value? Then take a look at our Phase Master cables. 2500 PHASE vs. TEMPERATURE PHASE MASTER 210 Superior phase stability vs. temperature makes this cable the ideal choice for phase-sensitive applications particularly those with wide operating temperature ranges. Phase Master's enhanced phase stability a result of a proprietary combination of high performance, tape wrapped PTFE dielectric and helically wrapped SPC shield offers: Improved system performance Less frequent calibration More precise measurements From environmental stress screening to electronically scanned radar systems, count on Phase Master assemblies to provide unparalleled value and performance. TYPICAL PHASE SHIFT, PPM 2000 1500 1000 500 0-500 -1000-60 -50-40 -30-20 -10 0 10 20 30 40 50 60 70 80 TEMPERATURE, C Typical Phase Shift Limits High value microwave and electronic interconnect solutions www.teledynestorm.com/microwave

PHASE MASTER SPECIFICATIONS PHASE MASTER 160 190 210 300 Cable Designator 64 63 62 61 Diameter (in/mm) 0.160/4.06 0.190/4.83 0.210/5.33 0.299/7.59 Operating Frequency (Max, GHz) 40 32 26.5 18 Attenuation Max @ 2 GHz (db/ft) 0.150 0.121 0.099 0.067 Attenuation Max @ 10 GHz (db/ft) 0.347 0.282 0.232 0.159 Attenuation Max @ (db/ft) 0.474 0.388 0.320 0.221 Attenuation Max @ 26.5 GHz (db/ft) 0.585 0.481 0.396 Attenuation Max @ 32 GHz (db/ft) 0.648 0.535 -- -- Attenuation Max @ 40 GHz (db/ft) 0.732 -- Power Handling Avg (watts @ 1 GHz) 527 759 878 1615 Phase Stability vs. Temp -- ppm (nom/tolerance) 365/125 70/100 865/150 445/150 35/100 800/125 470/125 90/125 575/125 Phase Stability vs. Flexure (@, nom) ±3.5 ±4 ±4.5 ±8 485/125 60/100 945/100 Shielding Effectiveness Min (db @ 1 GHz) > 90 > 90 > 90 > 90 Typical VSWR (2 straight connectors) 1.28 to 40 GHz 1.25 to 32 GHz 1.22 to 26.5 GHz 1.22 to Min Bend Radius (in/mm) 55 C +20 C +120 C Static Dynamic 0.75/19.1 1.5/38.2 0.95/24.1 1.9/48.3 1.0/25.4 2.0/50.8 1.5/38.1 3.0/76.2 Connector Retention to, pull (lbs/kg) 20/9.07 40/18.14 50/22.68 75/34.02 Velocity of Propagation (%) 87.0 82.4 84.0 84.6 Weight (grams/ ft/m) 12.12/39.76 16.65/54.63 19.40/63.65 39.00/127.95 Operating Temperature Range ( C) 55 to +125 55 to +125 55 to +125 55 to +125 ± 360 degree bends around a 3" mandrel (PM 160), 3.8" mandrel (PM 190), Subject to connector choice. 4" mandrel (PM 210) and 6" mandrel (PM 300) Specifications subject to change without notice. PHASE MASTER CONSTRUCTION A B C D E A Silver-plated copper center conductor D Silver-plated copper braid B Expanded PTFE dielectric E Extruded blue FEP jacket C Helically wrapped SPC flat wire shield

PHASE MASTER ORDERING INFORMATION: Part Number Designation PHASE MASTER 160 PART NUMBER 64 0 - Unarmored A - Hard Armored (polyolefin jacket) AN - Hard Armored (no polyolefin jacket) OPERATING FREQUENCY 40 GHz SMK (2.92 mm ) SP SMK (2.92 mm ) 2.4 mm SP 2.4 mm CODES SP Straight Plug 40 GHz SMK (2.92 mm ) SP 0505 0555 0506 0556 SMK (2.92 mm ) 0555 5555 0655 5556 2.4 mm SP 0506 0655 0606 0656 2.4 mm 0556 5556 0656 5656 IEEE Standard 287 064-0505-048 = Unarmored Phase Master 160, SMK (2.92 mm) SP to SMK (2.92 mm) SP (assembly operates to 40 GHz), 48 inches AN64-0606-180 = Hard Armored (no polyolefin jacket) Phase Master 160, 2.4 mm SP to 2.4 mm SP (assembly operates to 40 GHz), 180 inches PHASE MASTER 190 PART NUMBER 63 0 - Unarmored A - Hard Armored (polyolefin jacket) AN - Hard Armored (no polyolefin jacket) OPERATING FREQUENCY 32 GHz 2.92 mm SP 2.92 mm CODES SP Straight Plug 32 GHz 2.92 mm SP 0505 0555 2.92 mm 0555 5555 063-5555-048 = Unarmored Phase Master 190, 2.92 mm to 2.92 mm (assembly operates to 32 GHz), 48 inches A63-0505-180 = Hard Armored (polyolefin jacket) Phase Master 190, 2.92 mm SP to 2.92 mm SP (assembly operates to 32 GHz), 180 inches

PHASE MASTER ORDERING INFORMATION: Part Number Designation PHASE MASTER 210 PART NUMBER 62 0 - Unarmored R - Ruggedized (polyurethane jacket) A - Hard Armored (polyolefin jacket) AN - Hard Armored (no polyolefin jacket) 26.5 GHz 26.5 GHz 3.5 mm SP 3.5 mm OPERATING FREQUENCY SMA SP SMA SP 3.5 mm SP 0404 0454 0441 0104 0451 0204 0452 0304 0453 3.5 mm 0454 5454 4154 0154 5154 0254 5254 0354 5354 SMA SP 0441 4154 4141 0141 4151 0241 4152 0341 4153 SMA SP 0104 0154 0141 0101 0151 0102 0152 0103 0153 SMA 0451 5154 4151 0151 5151 0251 5152 0351 5153 TNC SP 0204 0254 0241 0102 0251 0202 0252 0203 0253 TNC 0452 5254 4152 0152 5152 0252 5252 0352 5253 N SP 0304 0354 0341 0103 0351 0203 0352 0303 0353 N 0453 5354 4153 0153 5153 0253 5253 0353 5353 SMA TNC SP TNC N SP N CODES SP Straight Plug 062-0404-048 = Unarmored Phase Master 210, 3.5 mm SP to 3.5 mm SP (assembly operates to 26.5 GHz), 48 inches R62-4141-120 = Ruggedized Phase Master 210, SMA SP to SMA SP (assembly operates to 26.5 GHz), 120 inches PHASE MASTER 300 PART NUMBER 61 0 - Unarmored A - Hard Armored (polyolefin jacket) AN - Hard Armored (no polyolefin jacket) SMA SP OPERATING FREQUENCY SMA TNC SP TNC N SP N SMA SP 0101 0151 0102 0152 0103 0153 SMA 0151 5151 0251 5152 0351 5153 TNC SP 0102 0251 0202 0252 0203 0253 TNC 0152 5152 0252 5252 0352 5253 N SP 0103 0351 0203 0352 0303 0353 N 0153 5153 0253 5253 0353 5353 CODES SP Straight Plug 061-0303-036 = Unarmored Phase Master 300, N SP to N SP (assembly operates to ), 36 inches AN61-0101-108 = Hard Armored (no polyolefin jacket) Phase Master 300, SMA SP to SMA SP (assembly operates to ), 108 inches

PHASE MASTER 10,000 10 9 8 7 6 5 4 3 PHASE MASTER CW POWER SEA LEVEL AND 25 C AVERAGE POWER - WATTS 1000 100 2 10 9 8 7 6 5 4 3 2 10 9 8 7 6 5 4 3 Phase Master 300 0.299" Phase Master 210 0.210" Phase Master 190 0.190" Phase Master 160 0.160" 20 2 0.1 5 6 7 8 9 10 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 2 3 4 20 30 40 0.1 1.0 10 40 FREQUENCY (GHz) FACTORY FORMED RIGHT-ANGLE (FFRA) S 1.25" Designed using straight connectors and a shrink tubing strain relief combination, FFRA connectors offer a moderate right-angle space advantage at a significant cost savings over traditional right-angle connectors. FFRA connectors are available for all Phase Master cable sizes. See the Connector tables for specific connectors available as FFRAs. Note: The dimensions given here are for PM160 with an SMK connector. Larger cables will have proportionally larger dimensions. Contact Storm for specifics. 2.25" MAX

& RUGGEDIZING OPTIONS The Hard Armored option (with and without polyolefin jacket) is available for all Phase Master cables The Ruggedized option (with polyurethane jacket) is available only for Phase Master 210 HARD ARMORED Polyolefin jacket : A Designed for both inside and outside environments where flexibility and weight are not as critical, but where the application requires the ultimate in cut and crush resistance (500 lbs/in). The cable is covered with a stainless steel interlocked armor and a cross-linked polyolefin jacket. Temperature: 54 C thru +125 C Diameter: Phase Master 160 0.300"/7.62 mm Phase Master 190 0.430"/10.92 mm Phase Master 210 0.430"/10.92 mm Phase Master 300 0.525"/13.34 mm HARD ARMORED No polyolefin jacket : AN Designed for both inside and outside environments where flexibility and weight are not as critical, but where the application requires the ultimate in cut and crush resistance (500 lbs/in). The cable is covered with a stainless steel interlocked armor. Temperature: 54 C thru +125 C Diameter: Phase Master 160 0.265"/6.73 mm Phase Master 190 0.395"/10.03 mm Phase Master 210 0.395"/10.03 mm Phase Master 300 0.475"/12.07 mm RUGGEDIZED Polyurethane jacket : R For applications similar to the above, where weight, flexibility, and moderate compression resistance (300 lbs/in) are important, but where abrasion resistance is also critical. The cable is covered with a flexible wound helix of passivated stainless steel wire and an extruded polyurethane jacket. Temperature: 54 C thru +100 C Diameter: Phase Master 210 0.360"/9.14 mm 10221 Werch Drive Woodridge, Illinois 60517 Tel 630.754.3300 Fax 630.754.3500 Toll Free 888.347.8676 storm_microwave@teledyne.com www.teledynestorm.com/microwave 3/12