Instructions. Quick Term II 2047MT 56. 3M Quick Term II. Silicone Rubber Termination (with High-K Stress Relief)

Similar documents
Quick Term II. Cold Shrink Silicone Rubber Termination. Quick Term II. Instruction Sheet

Instructions. Quick Term II 2047MT 74. Quick Term II. Silicone Rubber Termination

Cold Shrink Silicone Rubber Termination QT-III (With High-K Stress Relief)

3M Cold Shrink QT-II Silicone Rubber Indoor Termination Kits

3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kits

3M Cold Shrink QT-III Silicone Rubber Indoor Tubular Termination Kit

3M Cold Shrink QT-III Silicone Rubber Indoor Termination Kits With High-K Stress Relief

3M Cold Shrink QT-lll Silicone Rubber Skirted Termination Kit 7692-S-4, 7693-S-4, 7694-S-4, 7695-S-4, 7696-S-4

3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kit

3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kit With High-K Stress Relief

3M Cold Shrink QT-lll Silicone Rubber Indoor Tubular Termination Kits With High-K Stress Relief

3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kit

Motor Lead Pigtail or V-Stub Splice 5380 Series For 5/8 kv Non-Shielded and Shielded Feeder Cables (Tape, Wire or UniShield Cables)

Cold Shrink Silicone Rubber Termination QT-III 7672-S-8-JCN

3M Cold Shrink Splice Kit QS-III 5536A

QT-III Cold Shrink Silicone Rubber

3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8(S)-JCN

3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8-Tape/LC

Cold Shrink QS T Trifurcating Transition Splice Kit

3M Cold Shrink QT-III Silicone Rubber Termination

3M Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8-TOW/WOT (RW)

3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8-TOW/WOT

3M Cold Shrink QT-III Silicone Rubber Three-Core Termination Kits

3M Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8-TS (RW)

3M Cold Shrink QT-III Silicone Rubber 3/C Cabinet Mount Termination Kit

3M Cold Shrink Silicone Rubber Termination QT-III 7600-S-3G Series Three-Core Outdoor Termination

Cold Shrink QS2013-3T-WS Trifurcating Transition Splice Kit

3M Cold Shrink Silicone Rubber Outdoor Termination Kit QT-III 7600-S-3W Series

Cold Shrink - Silicone Rubber QTII(X)4S-32H Series Cable Termination Instructions

ELB ES. Product Installation Instructions

3 Reenterable Encapsulated PST Dome Closure

3M Cold Shrink QS-III Inline Splice Kits 15 kv 5513A, 5514A, 5515A and 5516A

3M Cold Shrink 1/C Transition Splice Kit QS-III, 5510A-1T-PILC Series

3M Cold Shrink QT-III Silicone Rubber Termination Kits 7640-T and 7650-T Series 5, 8, 15, 25/28 and 35 kv

QTII (X) Series Silicone Rubber Cold Shrink Termination Kits

QS-III. 5513A, 5514A, 5515A and 5516A 15 kv Cold Shrink Inline Splice Kits. Data Sheet CAUTION. 1. Product Description. 2. Applications.

DISTRIBUTION CONNECTORS SECTION DF COMPRESSION TERMINALS. Aluminum Compression Lugs Aluminum Bi-Metal Pin Terminals Copper Compression Lugs

8400 Series Fiber Distribution System

CS Fiber Optic Splice Case. Instruction

3 Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8 Series

DOCUMENT OBSOLETE. Volition. VF-45 Socket Termination and Maintenance Cleaning Kits COOL HAND TOOLS. CLEAN UP YOUR ACT. VF-45 Socket Termination Kit

COOPER POWER SERIES. 600 A 15/25 kv class BOL-T and separable splice connector assembly installation instructions

Branch Splice QS-2001B

COOPER POWER SERIES. Fused loadbreak elbow connector installation instructions. Loadbreak Apparatus Connectors MN650014EN

CP 600V Cable Protectors

3M Mechanical Shearbolt Connectors, QCI Series

3M Cold Shrink 3-Conductor Inline Splice Kits QS-III 5786A- MT, 5787A-MT and 5788A-MT 25/28 kv for use with Armored and Non- Armored 3/C Cable

COOPER POWER SERIES. 600 A 15 kv and 25 kv class BT-TAP connector system installation instructions. Deadbreak Apparatus Connectors MN650004EN

ELB ELB

COOPER POWER SERIES. Screened Separable Connectors MN650023EN. Effective October 2016 Supersedes March 2012 (IS )

COOPER POWER SERIES. Screened Separable Connectors MN650024EN. Effective October 2016 Supersedes March 2012 (IS )

COOPER POWER SERIES. 600 A 15/25 kv class T-OP II connector assembly installation instructions. Deadbreak Apparatus Connectors MN650048EN

Raychem CSJA Safety Instructions. Safety Instructions. Customer Service. Kit Contents. Installation Instructions

COOPER POWER SERIES. 600 A 35 kv class BT-TAP connector system installation instructions. Deadbreak Apparatus Connectors MN650003EN

3M Cold Shrink Splice Kits, QS T Series

3 TM Cold Applied Barrier Boot System

B T T T 2.11 MY29-11 (1) 4/0 AWG - MY29-11 (1) W30VT (2) U30RT (2) 300 kcmil 150 W30VT (2) YA30L-2TC W30RT (2) U28ART (2)

Terminations. 3M Cold Shrink Terminations FAX TERMINATIONS. Glossary of Terminations Terms 263 Cable Types for Terminating 264 3M

Lithium-Ion Battery-Powered Tools

Wind Energy Catalog Solutions for the Wind Industry

TBHD1 CRIMPING TOOL FOR THOMAS & BETTS TS DIES

BURNDY Compression. TWO HOLE HYLUG CODE CONDUCTOR STANDARD BARREL (Continued) Fig. 1 Fig. 2 Fig. 3. Conductor

Quick Splice II 5451R. 25/28 kv Molded Rubber Cable Repair Splicing Kit Data Sheet. 1. Product Description. 2. Applications

Cold Shrink Silicone Rubber Termination Kit QT-III 7620-S, 7690-S and 7680-S Series kv

Cable Ties. Data Sheet

A. General: Deliver, store and handle wire and cable in accordance with the manufacturer's instructions and as specified in Division 1.

Installation Instructions

Quick Splice II. 35 kv Molded Rubber Inline Splicing Kit Data Sheet. 2. Applications. 1. Product Description

Connector System Guide Compression Connectors Grounding Connectors Tools for Industrial Electrical Applications

Loadbreak Elbows. 3 Loadbreak Elbows. 200 Amp 5-15 kv Industrial pg Loadbreak Elbows. 200 Amp 25 kv Industrial pg. 254.

710 Splicing Rig. Instructions. January E

High Voltage Joints and Terminations up to 72,5 kv 145 kv

Installation Instructions K656CY, K656CH and K656I Deadbreak Receptacles

Type Termination Cable Size Copper Aluminum 2 CP2C1-1/0 CP1/0C1-2/0 CP2/0C1-4/0 CP4/0C1 CP4/0A1. Cable 250kcmil CP250C3 CP250A3

CTN U-TYPE DIE COLOR INDEX QTY 7/374 8/346 11/375 12/ /298 18/324 19/470 20/299 22/472 24/473 CTN U-TYPE DIE COLOR INDEX QTY

(K),(M)430TB/G Up to 36 kv

3M Products for Electrical Networks Wind Farm Capabilities. Leading Edge. Electrical Solutions for. Wind Farms

IS94012-ENG - AFN February Revision 6 - Supersedes edition of 28 January and / or. 3 x Stress control mastic, type MFC (Hi-K)

3M Closure System 2-Type Cover (505)

SLiC Aerial Terminal and Spiral End Seal for use with AMP* Quiet Front Terminal Blocks

TBM Series 3-Way Ball Valve

Installation Instructions

3M Locator Plate

Heavy Duty Copper Battery Terminals

Dfuser T/C Lock Override with LED

MANSI CLS Series LPG/CNG Closed Loop System with Harness and Actuator Motor

HVS S 15kV Class

4 AWG to 2000 kcmil at 15 kv, 2 AWG to 1750 kcmil at 25 kv and 1 AWG to 1500 kcmil at 34.5 kv. Stress Control

3M Electrical Tapes Product Selection Guide. Insulate & Protect. with Quality Tapes. Preliminary

3M Cold Shrink QT-III Silicone Rubber Skirted and Inverted Skirted Termination Kits, 7640-S, 7650-S and 7660-S Series 5, 8, 15, 25/28 and 35 kv

MR Gradient Cable Field Termination Training

Product Installation Instructions. Raychem Corporation Electrical Products 8000 Purfoy Road Fuquay-Varina, NC 27526

HI-LINE UTILITY SUPPLY CO. Phone: Fax: WEJTAP TOOLS WEJTAP HOT STICK ACCESSORY KIT

DIE AND COLOR CODE INFORMATION -1 B ~ Fig. 1. Installation Tooling Stud Figure Mechanical Hvdraulic Wire ~ W8CVT (1) W8CVT (1)

Dfuser T/C Lock-Un Lock

Armor Rods. Armor Rods NOMENCLATURE GENERAL RECOMMENDATIONS

3M Locator Plate

3M Electrical Markets Division. Rubber, Mastic and Specialty Tapes Application Guide. Choose the. Right Tape. for your. Electrical Project

SUBMERSIBLE SECONDARY CONNECTORS SSBC350-4LI. Cond. Range H W L

RACE PPE Manifolds and Up-Pipes

Transcription:

Instructions Quick Term II Silicone Rubber Termination (with High-K Stress Relief) IEEE Std. No. 48 990 Class Termination 5 kv Class 50 kv BIL Kit Contents Hi K Silicone Rubber Termination Scotch 70 Silicone Rubber Tape Strip(s) Neutral Wire Ground Clip Pack of Silicone Grease Instruction Sheet ÁÁ 5 to 4.5 kv Kit Selection Chart NOTE: Final determining factor is cable insulation diameter. Kit No. 568 568 568 5684 Cable Insulation O. D. Range 0.67. in. (6 8 mm) 0.84.8 in. ( 5 mm).08.80 in. (7 46 mm)..0 in. ( 5 mm) 5 kv #4 4/0 ( 00) 50 500 (0 50) 500 50 (50 65) 000 750 (500 850) Table Conductor Range (AWG & kcmil) 5/8 kv #4 /0 ( 60) /0 50 (50 85) 50 750 (85 400) 750 500 (400 800) 4.5 kv # 4/0 (50 00) 4/0 500 (00 50) 500 50 (50 65) M Quick Term II Silicone Rubber Termination Kits for use on Concentric Neutral (CN) Cable 568 568 Concentric Neutral Cable 568 5684 SCALE: ISSUE DATE: 7//9 ISSUE: Not to scale 047MT 56

Correct Installation of Termination Binding Wire or Vinyl Tape Ä Ä Ä Ä Ä Ä Ä Ä Ä Ä Ä ÁÁÁÁ ÁÁÁÁ Ridge at End of Cable Insulation Shield (Semi-Con) Ridge at End of High-K Tube Semi-Con Insulation Shield Cable Insulation Conductor High-K Stress Relief A. Prepare Cable. Check to be sure cable size fits within kit range as shown in Table (cover page).. Train cable into position and cut to length required for installation. Allow sufficient neutral wire length for neutral connection.. Bind neutral wires with a piece of wire or vinyl tape at dimension [A] + [B] Table. (See * below) 4. Bend the neutral wires over the binding wire or vinyl tape. 5. Remove cable semi-conductive insulation shield (semi-con) for a distance of [C] plus [B] Table. (See * below) 6. Remove cable insulation 4 from end of conductor for distance [B] Table. 5 7. Place a marker tape back from semi-con cut edge as shown. 6 Kit No. 568 568 568 5684 [A] * / 4 (98 mm) / 4 (98 mm) / 4 ( mm) / 4 ( mm) Dimension [B] Depth of Terminal Lug Barrel Table [C] * 8 / 4 (6 mm) 8 / 4 (6 mm) 9 (9 mm) 9 (9 mm) * add to [A] and [C] for short lug barrels ( or less). [A] [C] [B] Neutral Wire Binding Wire or Vinyl Tape 6 Marker Tape 4 Cable Insulation Semi-Con Insulation Shield Conductor 5 DO NOT LOOP NEUTRAL WIRES BEYOND MARKER TAPE

B. Install Lug or Connector. These units were designed to fit over Scotchlok and M copper and aluminum lugs. If other lugs will not fit through the core of the termination, slide termination on cable before installing lug. Do not remove core at this time.. When using M type lugs or connectors, refer to the tooling index (Pages 5 and 6) for crimping information.. Position lug or connector and crimp according to manufacturers directions. Remove excess contact aid and sharp crimp flash. C. Clean Cable Insulation and Lug Barrel Using Standard Practice. Wipe the cable insulation with an approved solvent. Do not allow solvent to touch semi-con insulation shield!. If abrasive must be used: a. Use on insulation only. Do not use abrasive on semi-con insulation shield! b. Use only aluminum oxide abrasive; grit 0 or finer or Scotch A Electrician s Abrasive Roll. c. Be careful not to reduce the cable insulation diameter below that allowed by the kit. D. Install Termination. Important: A track resistant seal must be made between the silicone termination insulator and connector using one of two gray Scotch 70 Silicone Rubber Electrical Tape Strips (contained in kit). If the lug barrel is smaller than the cable insulation, wrap the bottom end of the lug with gray silicone tape to the approximate diameter of the cable insulation.. Cover the edge of the semi-con insulation shield with a liberal coating of silicone grease. On this product the silicone grease does not serve as a lubricant. It must be used to fill the step at the semi-con cutoff. IMPORTANT Do Not Forget Silicone Grease ÁÁÁÁ Silicone Grease Gray Silicone Tape

Install Termination (continued). Slide the termination body onto the cable and remove core by unwinding, counter-clockwise, starting with the loose end. Make sure the termination body is butted up to the edge of the marker tape. 4 Tip: An occasional tug of the strand while unwinding will aid in core removal. Ä Ä Ä Ä Ä Ä 4 Marker Tape ÁÁÁ Gray Silicone Tape 4. Complete the lug seal using the second gray silicone tape strip. Overlap insulator by one inch and extend tape wrapping onto lug barrel as shown. 5 ÁÁ ÁÁ ÁÁ 5 Gray Silicone Tape E. Grounding. Snap stainless steel grounding clip onto base of termination. Clip must be applied to the base of the termination, between the bottom two rings. Loop one neutral strand around ground clip ends, pulling clip tight onto the termination.. Bundle all neutral wires together and connect to ground. Ä Stainless Steel Grounding Clip 4

Tooling Index Crimping Information for M Stem Connectors Copper/Aluminum Conductor CRIMPING TABLE FOR M STEM TYPE CONNECTOR Recommended Crimping Tools M Connector No. Manufacturer Mech. Tool Die (No. Crimps) Hydraulic Tool Die (No. Crimps) Burndy MD6 BG(4), W4(4) Y5, Y9, Y45** U5ART, U4 # Sol. #, # /0 SC000 SC000 SC000 Kearny T & B 0 5, 0 5 TBM 8 5/8 (4) Olive, 0, 40, Ton TBM 5 5/8 (4) 50* Anderson VC 6 Universal Burndy MD6 W669(0) 840(5)* Y5, Y9, Y45** U8ART /0 /0 4/0 SC000 SC000 SC0040 Kearny T & B 0 5, 0 5 TBM 8 840(5)* WH, WH TBM 5 840 66 Anderson VC 6 Universal Lug and Crimping Information for Scotchlok Copper/Aluminum Lugs 4006 thru 40079 One hole 40 thru 4078 Two hole Cable AWG/ kcmil Stud (in.) Scotchlok Lug Number Burndy Corporation MD6 MY9 Y4A Y5, 9, 45*, 46* CRIMPING TOOL-DIE SETS (NO. OF CRIMPS) Thomas & Betts Corporation ** Y000 TBM 5 TBM 8 TBM TBM 5 Square D Co. Anderson Div. VC6 ** VC6 FT** VC8C** ITT Blackburn Co. OD58 Kearne Nat l Div. TYPE 0 6 5 / 6 4006 W6 6 AWG A6CAB U6CABT Grey Grey 9 BY9 J 4 5 / 6 4000 W6 4 AWG A4CAB U4CABT Green Green 7 BY5 P 4004 W6 4005 W6 AWG AWG ACAB ACAB UCABT UCABT Pink Pink Pink Pink 4H 4H BY BY 4008 4009 W6 W6 AWG AWG ACAR ACAR UCART UCART Gold Gold Gold Gold 45 45 BY BY /0 400 400 40 W4 W4 W4 /0 /0 /0 A5AR A5AR A5AR U5ART U5ART U5ART Tan Tan Tan Tan Tan Tan 50 50 50 BY5 BY5 BY5 /0 4007 BG(4) /0 407 BG(4) /0 A6AR A6AR U6ART U6ART Olive Olive Olive Olive 54H 54H BYC BYC 5 /8 5 /8 /0 4004 W66(4) /0 A7AR 404 W66(4) /0 A7AR U7ART U7ART Ruby Ruby Ruby Ruby 60 60 77 77 4/0 40045 40046 4045 W660(4) W660(4) W660(4) 4/0 4/0 4/0 A8AR A8AR A8AR U8ART U8ART U8ART 66(4) 66(4) 66(4) BY5C(4) BY5C(4) BY5C(4) 840(4) 840(4) 840(4) 50 40049 40050 4049 W49 W49 W49 A9AR A9AR A9AR U9ART U9ART U9ART 7H(4) 7H(4) 7H(4) 7H 7H 7H 00 4005 405 A0AR A0AR U0ART U0ART 76H(4) 76H(4) 76 76 50 40056 40057 4056 UART UART UART 87H 87H 87H 400 4060 UART(4) 94H(4) 94H(4) 500 40067 4066 U4ART(4) U4ART(4) 06H(4) 06H(4) 06H 06H 600 4070 U6ART(4) 5H 750 4007 407 U9ART(4) U9ART(4) 5H(5) 5H(5) 000 40079 4078 S44ART(4) S44ART(4) 40H(4) 40H(4) * Y45 and Y46 accept all Y5 dies ( U series). For Y45 use PT655 adapter. For Y46 use PUADP adapter. ** Anderson VC6, VC6 FT, VC8C and Burndy Y000 require no die set. 5

Tooling Index Lug and Crimping Information for Scotchlok Copper Lugs 004 thru 0045 One hole 06 thru 068 One hole long barrel 45 thru 78 Two hole Cable AWG/ kcmil Stud (in.) Scotchlok Copper Lug Number Burndy Corporation MD6 MY9 Y4A CRIMPING TOOL-DIE SETS (NO. OF CRIMPS) Thomas & Betts Corporation Y5, Y9 Y45*, Y46* TBM 5 TBM 8 TBM 5 Square D Co. Anderson Div. VC6, VC6 FT** 6 0 / 4 5 / 6 004 005 006 6 AWG U5CRT Blue Blue Universal 4 0 / 4 008 009 00 W6 4 AWG A4CR U4CRT Grey Grey Universal / 4 5 / 6 00 00 004 W6 AWG ACR UCRT Brown Brown Universal 5 / 6 007 008 AWG ACR UCRT Green Green 7 Universal /0 5 / 6 00 00 W6 /0 A5R U5RT Pink Pink 4H Universal /0 006 06 W4 W4 /0 /0 A6R A6R U6RT U6RT Black Black Black Black 45 45 Universal Universal /0 004 W4 /0 A7R U7RT Orange Orange 04 W4 /0 A7R U7RT Orange Orange 50 50 Universal Universal 4/0 0045 045 45 BG BG(4) BG(4) 4/0 4/0 4/0 A8R U8RT U8RT U8RT Purple Purple Purple Purple Purple Purple 54H 54H 54H Universal Universal Universal 50 049 49 W66(4) 50 A9R U9RT Yellow Yellow 6 Universal 00 05 5 A0R U0RT White 66 Universal 50 056 56 AR URT Red(4) 7H(4) 400 060 60 AR URT Blue(4) 76H(4) 500 066 067 66 A4R U4RT Brown(4) 600 068 U6RT Green(4) 94H(4) / 68 750 7 Y9, Y45, Y46: U9RT(5) 06H(4) 000 78 Y45: S44RT(6) Y46: P44RT(6) 5H(4) IMPORTANT NOTICE TO PURCHASER: All statements, technical information and recommendations related to the Seller s products are based on information believed to be reliable, but the accuracy or completeness thereof is is not guaranteed. Before utilizing the product, the user should determine the suitability of the product for its intended use. The user assumes all risks and liability whatsoever in connection with such use. 4 700 6658 8 M Electrical Products Division 680 River Place Blvd. Austin, Texas 7876 9000 All statements or recommendations of the seller which are not contained in the Seller s current publications shall have no force or effect unless contained in an agreement signed by an authorized officer of the Seller. The statements contained herein are made in lieu of all warranties express or implied, including but not limited to the implied warranties of merchantability and fitness for a particular purpose which warranties are hereby expressly disclaimed. M 99 SELLER SHALL NOT BE LIABLE TO THE USER OR ANY OTHER PERSON UNDER ANY LEGAL THEORY, INCLUDING BUT NOT LIMITED TO NEGLIGENCE OR STRICT LIABILITY, FOR ANY INJURY OR FOR ANY DIRECT OR CONSEQUENTIAL DAMAGES SUSTAINED OR INCURRED BY REASON OF THE USE OF ANY OF THE SELLER S PRODUCTS.