Proline Promag 10H, 50H, 53H, 55H

Similar documents
Pressure transmitter COMPACT ECOnomic

SITRANS F M. Flow sensor MAG 1100 F 3/59

Flow Measurement SITRANS F M

Magnetic-Inductive Flow Meter FMI

Flow Measurement SITRANS F M. Flow sensor MAG 1100 F 4/57

SITRANS P measuring instruments for pressure

Magnetic-Inductive Flow Meter FMQ

Magnetic-Inductive flow Meter fmi

Magnetic-inductive flow meter EPS / UMF2. Technical data sheet

Flow Measurement SITRANS F M

Pressure transmitter UNIVERSAL CA

Resistance thermometer For sanitary applications Model TR22-A, exchangeable sensor

Series 240 Type 3349/3379 Pneumatic Control Valve Type 3349 Aseptic Angle Valve

Electromagnetic Flow Meter Owner s Manual HARDWARE

Dosimag. Technical Information. Electromagnetic volume flow measuring system for filling applications

SITRANS T measuring instruments for temperature

Security device Non return valve

NEUMO BioControl Model

Diaphragm monitoring system with clamp connection For sanitary applications Model DMS-FP

Diaphragm Valve, Metal

VERSAFLOW MAG 4000 Quick Start

Proline Promag 10L. Technical Information. Electromagnetic Flow Measuring System Flow measurement of liquids in water or wastewater applications

Technical Information Proline Promag 10L

Resistance thermometer For sanitary applications, exchangeable sensor Model TR22-A

2/2-way Angle Seat Valve, manually operated, for media up to +180 C

Level Probes multicap T DC 12 TA multicap T DC 11/16/21/26 TAN/TAS

2/2 way Globe Control Valve, threaded connection, 3/8" 3"

Diaphragm Valve, Metal

STEEMCO-MAS Flowmeter for Steam

Electromagnetic Flow Measuring System PROline promag 10 W

Hygienic Butterfly Valve VZFA Product range overview

Type Pressure Transmitter with display. Pressure Transmitter. Technical data. DN15-50 Body material. Stainless steel 316L Actuator material

Level Probes multicap T DC 12 TE multicap T DC 11/16/21/26 TEN/TES

T EN Type 3349 Aseptic Angle Valve With USP-VI diaphragm

STEEMCO Flowmeter for Steam

2/2-way Angle Seat Valve, manually operated, for media up to +180 C

Magnetic-inductive flow measurement device Type VOLUMTEC - best performance

Thermowell For sanitary applications Model TW61, for orbital welding

Resistance thermometer For sanitary applications Model TR22-B, for orbital welding

Series 240 Type and Type Pneumatic Control Valves Type 3347 Hygienic Angle Valve

611, 671. Diaphragm Valve, Metal

JUMO DELOS SI. Precision pressure transmitter with switching contacts and display. Application. Brief description. Key features.

In-line diaphragm seal with sterile connection For sanitary applications Model , aseptic connection per DIN 11864

Thermowell For sanitary applications Model TW22

Technical Manual. Register 10 CONTENTS - ASG

Thermowell For sanitary applications Model TW61, for orbital welding

Thermowell For sanitary applications Model TW61, for orbital welding

The EPSILON is based on the principle of measuring velocity in the pipe line, therefore the flow measurement is volumetric.

Technical Information itherm TT411

Diaphragm Valve, Metal

Diaphragm Valve, Metal

Pneumatic operated 2/2-way Diaphragm Valve

OPTIFLUX 6000 Technical Datasheet

611, 671. Diaphragm Valve, Metal

Options guide. Electromagnetic flowmeters. M9xx

Two-Way Metal Seated Ball Valve Type 85-M

653, 654. Diaphragm Valve, Metal

Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases

Thermowell For sanitary applications Model TW61, for orbital welding

Process connection. Further designs. Order code. to EN

Promass Q for the process industry

Installation Operation Maintenance

INSTRUCTIONS SITRANS F M MAGFLO Electromagnetic flowmeter type MAG 1100 FOOD, DN 10 - DN 100

Diaphragm Valve, Metal

Angle Seat Globe Valve, Metal

High-quality pressure sensor with mounted diaphragm seal With clamp connection Model DSS22T

Electromagnetic flowmeters

Two-Way Metal Seated Ball Valve Type 75-M

ORIMAS Mass Flowmeter

2/2 way Globe Control Valve, flange connection, 1/2" 4"

Ceraliquid CPS42/CPS42D/CPS43

Pipe surface resistance thermometer, for clamping Model TR57-M, miniature design

Cleanfit W CPA450. Technical Information. Retractable assembly for 12 mm sensors for DO/pH/ORP measurement

Angle Seat Globe Control Valve, Metal

Mark 908 Series. Pressure Regulators Mark 908X Piloted Blanketing Regulators

Type 147. Electrically Actuated Lug Butterfly Valve

Magnetic-inductive flow meter for hazardous areas

BUTTERFLY VALVE WITH WELDED ENDS INSTALLATION AND MAINTENANCE MANUAL

Angle Seat Globe Control Valve, Metal

Two-Way Soft Seated Ball Valve Type 75-S

Technical Information itherm TT411

Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids

Resistance Temperature Sensors for Hygienic and Sanitary Applications

Plastic tube variable area flowmeter for liquids and gases

THROTTLE VALVES FOR RELAYS AND RADIATORS Series 2009

Diaphragm Valve, Metal

WATERFLUX 3070 Quick Start

MS 2500 FLANGED SENSOR WITH A WIDE RANGE OF FLANGE SIZES. Warranty conditions are available on this website: only in English version

Level Probe multicap DC 16

Rosemount 3051CFA Annubar Flowmeter

Pneumatic Butterfly Valve Type 3335 / AT

BIOVENT. Hygienic Valve

Magnetic Inductive Flow

22-25 LA VALVOTECNICA CIT

Safety Instructions Proline Promass 300

VersaFlow Mag 3000 Electromagnetic Flow Sensor Technical Datasheet. Specification

Indumax P CLS50. Technical Information. Highly resistant, inductive conductivity sensor for standard, hazardous and high-temperature applications

BGN. All Metal Variable Area Flow Meter. Technical Data Sheet

Pneumatically operated zero dead volume T-Valve CLASSIC

Miniature resistance thermometer For sanitary applications Model TR21-A, with flange connection

Transcription:

Supplementary documentation for the Operating Instructions Supplementary information to following modifications: - New nominal diameters DN 125 to 150 (5 to 6") - New process connections for nominal diameters - New mechanical construction for nominal diameters DN 40 to 100 (1½ to 4") The following additional diameters DN 125 (5") and DN 150 (6") have been added to the Promag 10H, 50H, 53H and 55H as well as process connections with a new sealing system. In addition the mechanical constructions for the nominal diameters DN 40 100 (1½ 4") have been changed. In this documentation you will find the supplementary information for the following documentations: BA00082D: Proline Promag 10 HART BA00046D: Proline Promag 50 HART BA00055D: Proline Promag 50 PROFIBUS DP/PA BA047D: Proline Promag 53 HART BA052D: Proline Promag 53 FOUNDATION FIELDBUS BA117D: Proline Promag 53 MODBUS BA053D: Proline Promag 53 PROFIBUS DP/PA BA119D: Proline Promag 55 HART BA126D: Proline Promag 55 FOUNDATION FIELDBUS BA00124D: Proline Promag 55 PROFIBUS DP/PA SD00160D/06/EN/01.12 71184812

Identification Nameplate of the transmitter 2 3 4 1 5 6 7 8 9 Order Code: Ser. no.: Ext. ord. cd.: i 12 13 10 11 Example of transmitter nameplate 1 Name of transmitter 2 Order code 3 Serial number (Ser.No.) 4 Extended order code (Ext. ord. co.) 5 Power supply, frequency, power consumption 6 Additional function and software 7 Available inputs and outputs 8 Reserved for additional information 9 Please refer to operating instructions 10 Reserved for certificates, approvals and for additional information on device version 11 Patents 12 Degree of protection 13 Ambient temperature range A0015928 2 Endress+Hauser

Nameplate of the sensor 1 2 3 4 5 7 10 13 15 16 18 Order Code: Ser. no.: Ext. ord. cd.: K-factor: Tm: Materials: Electrodes: i 6 8 9 11 12 14 17 Example of sensor nameplate 1 Name of the sensor 2 Order code 3 Serial number (Ser. no.) 4 Extended order code (Ext. ord. cd.) 5 Calibration factor with zero point (K-factor) 6 Calibration tolerance 7 Flange nominal diameter and nominal pressure 8 Fluid temperature range (Tm) 9 Material of measuring tubes (Materials) 10 Materials of measuring electrodes (Electrodes) 11 Reserved for additional information 12 Reserved for additional information 13 Ambient temperature range 14 Degree of protection 15 Please refer to operating instructions 16 Reserved for additional information on device version (approvals, certificates) 17 Reserved for additional information on device version (approvals, certificates) 18 Flow direction A0017597 Endress+Hauser 3

Installation Recommended flow DN 125 to 150 (5 to 6") Installing the sensor " Caution! Min./max. full scale value (v 0.3 or 10 m/s): SI units: DN 125 (5"): 220 to 7500 dm 3 /min DN 150 (6"): 20 to 600 m 3 /h US units: DN 125 (5"): 60 to 1950 gal/min DN 150 (6"): 90 to 2650 gal/min The sensor is supplied to order, with or without pre-installed process connections. Pre-installed process connections are secured to the sensor with 4 or 6 hex-head threaded fasteners. The sensor might require support or additional attachments, depending on the application and the length of the piping run. When plastic process connections are used, the sensor must be additionally supported mechanically. A wall-mounting kit can be ordered separately from Endress+Hauser as an accessory. C Promag H process connections (DN 40 to 150, 1½ to 6") C = /process connections with aseptic gasket seal weld nipples (DIN 11850, ODT/SMS, ASME BPE, ISO 2037 ) clamp (ISO 2852, DIN 32676, L14 AM7) coupling (DIN 11851, DIN 11864-1, ISO 2853, SMS 1145) flange (DIN 11864-2) a0004301 " Caution! Seals When installing the process connections, make sure that the seals are clean and correctly centered. With metal process connections, you must fully tighten the screws. The process connection forms a metallic connection with the sensor, which ensures a defined compression of the seal. With plastic process connections, note the max. torques for lubricated threads (7 Nm / 5.2 lbf ft). With plastic flanges, always use seals between connection and counter flange. The seals must be replaced periodically, depending on the application, particularly in the case of gasket seals (aseptic version)! The period between changes depends on the frequency of cleaning cycles, the cleaning temperature and the fluid temperature. Replacement seals can be ordered as accessories. 4 Endress+Hauser

" Caution!! Note! Welding the transmitter into the piping (weld nipples) Risk of destroying the measuring electronics. Make sure that the welding machine is not grounded via the sensor or the transmitter. 1. Tack-weld the sensor into the pipe. A suitable welding jig can be ordered separately as an accessory. 2. Loosen the screws on the process connection flange and remove the sensor, complete with the seal, from the pipe. 3. Weld the process connection to the pipe. 4. Reinstall the sensor in the pipe. Make sure that everything is clean and that the seal is correctly seated. If thin-walled foodstuffs pipes are not welded correctly, the heat could damage the installed seal. It is therefore advisable to remove the sensor and the seal prior to welding. The pipe has to be spread approximately 8 mm to permit disassembly. Cleaning with pigs If pigs are used for cleaning, it is essential to take the inside diameters of the measuring tube and process connection into account. All the dimensions and lengths of the sensor and transmitter are provided in the separate documentation "Technical Documentation". Technical data Medium temperature range DN 125 to 150 (5 to 6") Sensor and seals: -20 to +150 C (-4 to +302 F) Medium pressure range (nominal pressure) DN 40 to 150 (1/12 to 6") The permitted nominal pressure depends on the process connection, the seal and the nominal diameter: Process connections with aseptic gasket seal (1.44404/316L) Nominal diameter [mm] 40 50 65 80 100 125 150 [inch] 1½" 2" - 3" 4" 5" 6" Weld socket: ODT/SMS Weld socket: DIN 11850 For order codes with suffixes +CA/+CB PN 40 PN 25 (362.5 psi) PN 16 (232 psi) Weld socket: ISO 2037 PN 40 PN 25 (362.5 psi) PN16 (232 psi) Weld socket: ASME BPE PN 40 PN 25 (362.5 psi) - PN 16 (232 psi) Clamp: ISO 2852, DIN 32676, L14 AM7 PN 10 (145 psi) Coupling: SC DIN 11851 For order codes with suffixes +CA/+CB PN 40 Coupling: SMS 1145 Coupling: DIN 11864-1, ISO 2853 PN 25 (362.5 psi) For order codes with suffixes +CA/+CB PN 40 Flange: DIN 11864-2 PN 25 (362.5 psi) - For order codes with suffixes +CA/+CB PN 25 (362.5 psi) PN 10 (145 psi) Endress+Hauser 5

Pressure tightness DN 125 to 150 (5 to 6") Measuring tube lining: PFA Nominal diameter Limit values for abs. pressure [mbar] ([psi]) at fluid temperatures: [mm] [inch] 25 C (77 F) 80 C (176 F) 100 C (212 F) 130 C (266 F) 150 C (302 F) 125 to 150 5 to 6" 0 0 0 0 0 Weight Promag 10H: Weight in SI units and US units Nominal diameter Compact version (DIN) Remote version (without cable; DIN) Sensor Transmitter (wall-mount housing) [mm] [inch] [kg] [lbs] [kg] [lbs] [kg] [lbs] 40 1½" 5.5 12.1 4.1 4.1 3.1 7.0 50 2" 6.0 13.2 4.6 4.1 3.1 7.0 65 6.8 15.0 5.4 4.6 3.1 7.0 80 3" 7.4 16.3 6.0 6.0 3.1 7.0 100 4" 8.7 19.2 7.3 7.3 3.1 7.0 125 5" 14.1 31.1 12.7 12.7 3.1 7.0 150 6" 16.5 36.4 15.1 15.1 3.1 7.0 Transmitter (compact version): 1.8 kg (3.97 lbs) Weight data valid for standard pressure ratings and without packaging material. Promag 50H, 53H und 55H: Weight in SI units Nominal diameter Compact version (DIN) Remote version (without cable; DIN) DN Aluminum field housing Stainless steel field housing Sensor Transmitter (wallmount housing) [mm] [kg] [kg] [kg] [kg] 40 7.1 7.6 4.1 6 50 7.6 8.1 4.6 6 65 8.4 8.9 5.4 6 80 9 9.5 6.0 6 100 10.3 10.8 7.3 6 125 15.7 16.2 12.7 6 150 18.1 18.6 15.1 6 Transmitter (compact version): 3.4 kg Weight data valid for standard pressure ratings and without packaging material. 6 Endress+Hauser

Weight in US units Nominal diameter Compact version (DIN) Remote version (without cable; DIN) DN Aluminum field housing Stainless steel field housing Sensor Transmitter (wallmount housing) [in] [lbs] [lbs] [lbs] [lbs] 1½" 15.7 16.8 4.1 13 2" 16.8 17.9 4.6 13 3" 19.8 20.9 6.0 13 4" 22.7 23.8 7.3 13 5" 34.6 35.7 12.7 13 6" 39.9 41.0 15.1 13 Transmitter (compact version): 7.5 lbs Weight data valid for standard pressure ratings and without packaging material. Material DN 125 to 150 (5 to 6") Process connections Seals: gasket seal (EPDM*, Silicon*) * = USP class VI; FDA 21 CFR 177.2600: 3A With gasket seals: Weld sockets (DIN 11850, ODT/SMS, ASME BPE, ISO 2037) Clamps (ISO 2852, DIN 32676, L14 AM7) Coupling (DIN 11851, DIN 11864-1, ISO 2853, SMS 1145) Flange (DIN 11864-2) Endress+Hauser 7

www.endress.com/worldwide SD00160D/06/EN/01.12 71184812 FM+SGML 9.0 ProMoDo