dynacon floor heating manifold with automatic flow control Pressurisation & Water Quality Balancing & Control Thermostatic Control EnGInEERInG advantage
Dynacon Description HEIMEIER Dynacon floor heating manifold with automatic flow controllers in supply pipe for each individual heating circuit. Thermostatic inserts with M 0 x. connection in return flow. Matching all HEIMEIER actuators. Stainless steel manifold with flat-sealing connection, union nut. Pipe socket spacing, heating circuits, 0 mm. / manual bleeder, self-sealing. Drain with / hose connection. Wall holder with soundproofing, including mounting material. / Eurokonus pipe connections, suitable for HEIMEIER compression fittings. The following manifold connection kits are available: - Connection kit with Globo ball valves - Connection kit with TBV control valve and Globo ball valve - Connection kit with Zeparo Vent air separator in supply pipe and Zeparo Dirt sludge separator in return - Connection kit with Globo ball valve, including spacer for heat meter in return and Globo ball valve with connection for direct measurement in supply pipe. - Connection kit fixed value control station with high-efficiency pump for controlling the supply temperature. Manifold boxes available as surface-mounted and flush-mounted versions. Assembly Flow controller. Setting cap with blocking ring. Maintenance-free O-ring seal. Manifold 7. Adjustment spindle. Compression spring 8. Sleeve. Cartridge 9. Control element. Connection nipple for heating circuit Automatic hydraulic balancing by direct setting of required flow rate Time and cost-saving commissioning solution Control cartridge ensures constant flow rate Set up and forget Flow rate easily adapted to different heating loads Optimum temperature distribution Saves energy Increased comfort Application Dynacon adjusts the flow rate in the individual heating circuits directly in l/h. This means hydraulic balancing is achieved in one simple operation. The set flow rate is constantly adapted, i.e. if the rate becomes too high, e.g. due to closing adjacent circuits, Dynacon controls the flow automatically to the set value. The control cartridge always ensures a constant flow. This makes Dynacon heating circuit manifolds a time and cost-saving solution especially for system commissioning. With conventional heating circuit manifolds with throttle valves and flow indicators setting the required water quantities is a time-consuming affair. The setting required at the throttle valves must either be calculated or set using flow indicators at the manifold. However, the quantities of water distributed in this way only correspond to maximum requirements. When individual heating circuits are turned off, the quantity of water no longer required is distributed over the adjacent circuits resulting in an oversupply in these circuits. The automatic hydraulic balance with Dynacon avoids this oversupply in individual heating circuits. This ensures optimum temperature distribution, saves energy and increases comfort.
Application example Technical data Flow rate range per heating circuit: 0-00 l/h 0 00 0 00 0 00 0 max. min. Calculation example: Target: Set value of Dynacon flow controller Given: Heat flow, heating circuit º = 0 W Temperature spread Δt = 8 K (/ C) Solution: Mass flow ª = º / (c Δt) = 0 / (. 8) = 0 kg/h Flow regulator setting at Dynacon manifold: 0 l/h l/h 0 0 0 00 kpa Minimum differential pressure via flow regulator: 0 - kpa depending on target value
Article numbers Dynacon underfloor heating circuit manifold with automatic flow control Heating circuits 90-0.800 90-0.800 90-0.800 90-0.800 90-0.800 7 90-07.800 8 90-08.800 9 90-09.800 0 90-0.800 90-.800 90-.800 Connection kit with Globo ball valves with red end cap in infeed and blue end cap in return. 99-0.800 Connection kit with TBV control valve and Globo ball valve including measuring nipple for measuring differential pressure and flow rate. 99-0.800 Connection kit with Zeparo Vent air separator in infeed and Zeparo Dirt sludge separator in return 99-0.800 S-connection For connection kit. Installation aid for return in manifold boxes. 99-00.
Connection kit with Globo ball valve, including spacer for heat meter in return Globo ball valve with connection for direct measurement in infeed. 99-0.800 Connection kit, fixed value control station with high-efficiency pump 99-0.800 Manifold boxes Flush-mounted box, installation depth 0-0 mm Size W x H 90 x 70 mm 99-80.800 7 x 70 mm 99-8.800 7 x 70 mm 99-8.800 87 x 70 mm 99-8.800,0 x 70 mm 99-8.800,7 x 70 mm 99-8.800 Manifold boxes Surface-mounted box, installation depth 0 mm Size W x H 9 x 0 mm 99-90.800 8 x 0 mm 99-9.800 7 x 0 mm 99-9.800 88 x 0 mm 99-9.800,0 x 0 mm 99-9.800,8 x 0 mm 99-9.800 Accessories Manual control cap for all HEIMEIER thermostatic valve bodies. With direct connection and end cover, white. Length compensator For holding plastic, copper, precision steel or composite pipes. For valves with G / male thread connection. Nickel-plated brass. L 0-0. G/ x G/ 97-0. G/ x G/ 0 97-0.
Compression fitting for plastic pipe. Nickel-plated brass. Adaptor - G / male thread. Ø pipe x -. x -. 7x -7. 8x -8. 0x -0. Compression fitting for copper or precision steel pipes. Adaptor - G / male thread. Nickel-plated brass. Metal-to-metal joint. Support bushes must be used for pipes with 0.8 mm thick walls. Observe data provided by pipe manufacturer. Support bush for copper and precision steel pipe with a wall thickness of mm. Brass. Ø pipe 8-. 8-. 8-. 8 8-8. L Ø pipe.0 00-.70.0 00-.70. 00-.70.8 8 00-8.70 Compression fitting for copper or precision steel pipes. Soft sealing. Nickel-plated brass. Adaptor - G / male thread. Ø pipe -. 8-8. Compression fitting for composite pipe. Nickel-plated brass. Adaptor - G / male thread. Ø pipe x -. Screw connection For holding plastic, copper, precision steel or composite pipes. Nickel-plated brass. L G/ x R/ -.08 Double nipple on both sides, for holding plastic, copper, precision steel or composite pipes. Nickel-plated brass. G/ x G/ -0.08 Automatic flow control insert Spare insert. 90-00.00
floor heating manifold - dynacon Dimensions - manifold and connection kits 00 90 Set Set Set + Set + 99-00. Set + Set + 99-00. Set Set Heating circuit manifold, heating circuits Length [mm] 0 90 0 90 0 90 7 0 8 90 9 0 0 90 0 90 Length, including kit + 0 mm bend Length, including kit + 0 mm bend Length, including kit and kit + 0 mm bend Length, including kit and kit + 0 mm bend Length, including kit + 0 mm bend Length, including kit Fixed value control station 7 7 7 7 7 7 77 8 0 0 0 0 0 0 0 0 70 70 80 80 0 00 0 00 0 700 70 800 80 900 90 000 0 0 0 0 0 70 70 80 80 90 90 00 7 7 8 8 9 9 80 0 80 0 80 70 780 80 880 90 980 00 Supplied without bend 7
Dimensions - manifold boxes 90-90/9...800 90-80/8...800 Size W x H [mm] Size W x H [mm] Surface-mounted box, installation depth 0 mm Flush-mounted box, installation depth 0-0 mm 9 x 0 90 x 70 8 x 0 7 x 70 7 x 0 7 x 70 88 x 0 87 x 70 0 x 0 0 x 70 8 x 0 7 x 70 The products, texts, photographs, graphics and diagrams in this document may be subject to alteration by TA Hydronics without prior notice or reasons being given. For the most up to date information about our products and specifications, please visit www.tahydronics.com. 0-8.8 0.0 partner in your country www.tahydronics.com