dynacon Floor heating manifold with automatic flow control Pressurisation & Water Quality Balancing & Control Thermostatic Control EnGInEERInG advantage dynacon adjusts the flow rate in the individual heating circuits directly in l/h. this means hydraulic balancing is achieved in one simple operation. the set flow rate is constantly adapted, i.e. if the rate becomes too high, e.g. due to closing adjacent circuits, dynacon controls the flow automatically to the set value. the control cartridge always ensures a constant flow. this makes dynacon heating circuit manifolds a time and cost-saving solution especially for system commissioning.
Technical description HeiMeier dynacon floor heating manifold with automatic flow controllers in supply pipe for each individual heating circuit. thermostatic inserts with M0x. connection in return flow. Matching all HeiMeier and ta M0x, actuators. stainless steel manifold with flat-sealing connection, union nut. Pipe socket spacing, heating circuits, 0 mm. / manual bleeder, self-sealing. drain with / hose connection. Wall holder with soundproofing, including mounting material. / eurokonus pipe connections, suitable for HeiMeier compression fittings. operating temperature C to 70 C. Maximum allowable working pressure 0 bar. the following manifold connection kits are available: - Connection kit with globo ball valves - Connection kit with tbv control valve and globo ball valve - Connection kit with Zeparo Vent air separator in supply pipe and Zeparo dirt sludge separator in return - Connection kit with globo ball valve, including spacer for heat meter in return and globo ball valve with connection for direct measurement in supply pipe. - Connection kit fixed value control station with high-efficiency pump for controlling the supply temperature. Manifold boxes available as surface-mounted and flush-mounted versions. construction Flow controller. setting cap with blocking ring. Maintenance-free o-ring seal. Manifold 7. adjustment spindle. Compression spring 8. sleeve. Cartridge 9. Control element. Connection nipple for heating circuit Automatic hydraulic balancing by direct setting of required flow rate Time and cost-saving commissioning solution Control cartridge ensures constant flow rate Set up and forget Flow rate easily adapted to different heating loads Optimum temperature distribution Saves energy Increased comfort application dynacon adjusts the flow rate in the individual heating circuits directly in l/h. this means hydraulic balancing is achieved in one simple operation. the set flow rate is constantly adapted, i.e. if the rate becomes too high, e.g. due to closing adjacent circuits, dynacon controls the flow automatically to the set value. the control cartridge always ensures a constant flow. this makes dynacon heating circuit manifolds a time and cost-saving solution especially for system commissioning. With conventional heating circuit manifolds with throttle valves and flow indicators setting the required water quantities is a time-consuming affair. the setting required at the throttle valves must either be calculated or set using flow indicators at the manifold. However, the quantities of water distributed in this way only correspond to maximum requirements. When individual heating circuits are turned off, the quantity of water no longer required is distributed over the adjacent circuits resulting in an oversupply in these circuits. the automatic hydraulic balance with dynacon avoids this oversupply in individual heating circuits. this ensures optimum temperature distribution, saves energy and increases comfort.
Sample application Technical data Flow rate range per heating circuit: 0-00 l/h 0 00 0 00 0 00 0 max. min. Sample calculation: target: set value of dynacon flow controller given: Heat flow, heating circuit º = 0 W temperature spread Δt = 8 K (/ C) solution: Mass flow ª = º / (c Δt) = 0 / (, 8) = 0 kg/h Flow regulator setting at dynacon manifold: 0 l/h l/h 0 0 0 00 kpa Minimum differential pressure via flow regulator: 0 - kpa depending on target value
articles Dynacon underfloor heating circuit manifold with automatic flow control Heating circuits 0079 90-0.800 00797 90-0.800 007980 90-0.800 007999 90-0.800 007700 90-0.800 7 00770 90-07.800 8 00770 90-08.800 9 00770 90-09.800 0 007708 90-0.800 007700 90-.800 007709 90-.800 Connection kit with Globo ball valves, DN 0 with red end cap in supply and blue end cap in return. kvs 9,90 007708 99-0.800 Connection kit with TBV NF control valve and Globo ball valve, DN 0 including measuring nipple for measuring differential pressure and flow rate. kvs q max [m /h],0, 0077 99-0.800 Connection kit with Zeparo Vent air separator in supply and Zeparo Dirt sludge separator in return, DN 0 kvs q max [m /h],7, 0077 99-0.800 S-connection For connection kit. installation aid for return in manifold boxes. 00777 99-00.
Connection kit with Globo ball valve DN 0, including spacer for heat meter in return globo ball valve with connection for direct measurement in supply. kvs 9,90 0077 99-0.800 Connection kit, fixed value control station with high-efficiency pump grundfos alpha - 0 0, thermostatic valve with contact sensor and electrical pipe contact safety switch 0V, a. Setting range thermostatic head Setting range electrical pipe-contact sensor 0 C-0 C 0 C-90 C 0077 99-0.800 Manifold boxes Flush-mounted box, installation depth 0-0 mm Size B x H 90 x 70 mm 00790 99-80.800 7 x 70 mm 007907 99-8.800 7 x 70 mm 007908 99-8.800 87 x 70 mm 007909 99-8.800.0 x 70 mm 007909 99-8.800.7 x 70 mm 00798 99-8.800 Manifold boxes Surface-mounted box, installation depth 0 mm Size B x H 9 x 0 mm 00797 99-90.800 8 x 0 mm 0079 99-9.800 7 x 0 mm 0079 99-9.800 88 x 0 mm 0079 99-9.800.0 x 0 mm 0079 99-9.800.8 x 0 mm 00797 99-9.800 Kvs = m /h at a pressure drop of bar and fully open valve. accessories Handwheel for all HeiMeier thermostatic valve bodies. With direct connection, white. 009 0-0. Length adjustment fitting For clamping plastic, copper, precision steel or multi-layer pipes. For valves with male thread connection g /. Brass nickel-plated. L g/ x g/ 00980 97-0. g/ x g/ 0 00989 97-0.
Compression fitting for plastic pipes. Male thread connection g /. nickel plated brass. Ø Pipe x 008 -. x 008 -. 7x 009-7. 8x 000-8. 0x 008-0. Compression fitting for copper or precision steel pipe. Connection male thread g /. Brass nickel-plated. With a pipe wall thickness of 0.8- mm insert supporting sleeves. Heed pipe manufacturer s technical advice. Support sleeve for copper or precision steel pipe with a mm wall thickness. Brass. Ø Pipe 00 8-. 007 8-. 009 8-. 8 008 8-8. L Ø Pipe,0 0070 00-.70,0 00797 00-.70, 0089 00-.70,8 8 0088 00-8.70 Compression fitting for copper or precision steel pipes. Male thread connection g /. soft sealed. nickel-plated brass. Ø Pipe 008 -. 8 000-8. Compression fitting for multi-layer pipes. Male thread connection g /. nickel-plated brass. Ø Pipe x 007 -. Double connection fitting For clamping plastic, copper, precision steel or multi-layer pipes. Brass, nickel-plated. L g/ x r/ 0008 -.08 Double nipple Both sides for clamping plastic, copper, precision steel or multi-layer pipes. Brass nickel-plated. g/ x g/ 00-0.08 Automatic flow control insert spare insert. 007 90-00.00
Floor Heating ManiFolds - dynacon Dimensions - manifold and connection kits 00 90 99-0.800 99-0.800 99-0.800 + 99-0.800 + 99-00. 99-0.800 + 99-0.800 + 99-00. 99-0.800 99-0.800 Heating circuit manifold, heating circuits Length [mm] 7 8 9 0 0 90 0 90 0 90 0 90 0 90 0 90 length, including kit + 0 mm bend length, including kit + 0 mm bend length, including kit and kit + 0 mm bend length, including kit and kit + 0 mm bend length, including kit + 0 mm bend length, including kit Fixed value control station 7 7 7 7 7 7 77 8 0 0 0 0 0 0 0 0 70 70 80 80 0 00 0 00 0 700 70 800 80 900 90 000 0 0 0 0 0 70 70 80 80 90 90 00 7 7 8 8 9 9 80 0 80 0 80 70 780 80 880 90 980 00 supplied without bend 7
Dimensions - manifold boxes 90-90/9...800 90-80/8...800 Size W x H [mm] Size W x H [mm] Surface-mounted box, installation depth 0 mm Flush-mounted box, installation depth 0-0 mm 9 x 0 90 x 70 8 x 0 7 x 70 7 x 0 7 x 70 88 x 0 87 x 70 0 x 0 0 x 70 8 x 0 7 x 70 The products, texts, photographs, graphics and diagrams in this document may be subject to alteration by TA Hydronics without prior notice or reasons being given. For the most up to date information about our products and specifications, please visit www.tahydronics.com. 0-8.8 0.0 partner in your country www.tahydronics.com