Taluka: Thasra Dist : Kheda Pin: 388 239 Telephone No. 02699-235 522 Fax No. 02699-235 607 CHIEF ENGINEER (C&O), GSECL,, INVITES TENDERS FROM INTERESTED BIDDERS, FOR SUPPLY OF ABOVE MATERIAL. THE DETAILS OF THE SAME ARE GIVEN BELOW. BIDDERS SHOULD SUBMIT THE DOWNLOADED DOCUMENTS, DULY FILLED, STAMPED AND SIGNED, AS PER THE INSTRUCTIONS GIVEN HEREUNDER. 1 Estimated Cost RS. 238500 2 Last date of issue of tender N.A. 3 Last date of submission of TENDER Up to 3.00 p.m. on or before due (By R.P.A.D. Only) date 4 Date of opening (if possible) TECHNICAL BID ONLY 3.30 p.m. on due date 5 Time limit for completion 3 TO 4 MONTHS 6 Earnest Money Deposit RS. 2385 7 Security Deposit 10% OF ORDER VALUE 8 Tender fee RS. 500 9 Delivery of goods (A) Sample Approval within NO (A) Bulk Supply (After Approval of sample) 3 TO 4 MONTHS 10 Validity of rates 120 DAYS 1. Tender Fee (non refundable)will be accepted by Demand Draft only. The DD should be drawn in favour of Gujarat State Electricity Corporation Limited, TA-Thasra Dist. - Kheda payable at DENA BANK, WTPS 2. Earnest Money Deposit (refundable)will be accepted either by Demand Draft in favour of Gujarat State Electricity Corporation Limited, TA-Thasra Dist. - Kheda payable at DENA BANK, WTPS or by Bank Guarantee of any of the nationalized/approved Bank of GSECL. GSECL has right to reject any or all tenders without assigning any reason thereof is reserved by competent authority. DD No. and Bank Guarantee No. & date Signature of the bidder Page 1
Taluka: Thasra Dist : Kheda Pin: 388239 Telephone No. 02699-235522 Fax No. 02699-235607 should be mentioned on envelope invariably on Technical Bid Cover as well as main Cover. 3. Please submit Technical Bid (this document) along with General Terms and conditions and annexures duly filled and signed/stamped in Technical bid cover. Price Bid (Schedule B) & Form A must be kept in separate cover. Both the above covers (i.e. Technical Bid & Price Bid cover) are to be kept in a Big envelope super scribing the tender number, subject & due date of opening. 4. Vendor registration with GSECL is not compulsory required for submitting the Tender. 5. Bidders are advised to visit our above websites regularly up to opening of bid for corrigendum if any & submit corrected copy of tender (otherwise their offer will not be considered for opening) & extension of due date. Postal Address: Gujarat State Electricity Corporation Limited Wanakbori Thermal Power Station TA-Thasra Dist. - Kheda 388 239 Signature of the bidder Page 2
Taluka: Thasra Dist : Kheda Pin: 388 239 Telephone No. 02699-235 522 Fax No. 02699-235 607 TECHNICAL BID Reference No. : WP/SUPPLY/RFQ-14523E/IMD1 Sr. No. Description of Material Qty. Reqd Unit 1 COMBINED PRESS. AND TEMP. GAUGEFOR FRECON- 4 Number 22 2-1/2" DIAL 1/4" BSP FLARE 0-150PSI, A.C. PLANT 2 COMBINED PRESS. AND TEMP. GAUGEFOR FRECON- 4 Number 22 2-1/2" DIAL 1/4" BSP FLARE 0-300PSI, A.C. PLANT 3 COMBINED PRESS. AND TEMP. GAUGEFOR FRECON- 4 Number 22 2-1/2" DIAL 1/4" BSP FLARE 0-450PSI, A.C. PLANT 4 INDFOSS MAKE DIFF. PRESS. SWITCH MP-55 WITH 6 Number TERMINAL TIMING RELAY 1/4" FLARE CONNECTION, A.C. PLANT 5 INDFOSS MAKE HIGH/LOW PRESS. CONTROL 6 Number SWITCH MP-15 1/4" FLARE CONNECTION, A.C. PLANT 6 SPORLAN MAKE THERMOSTATIC EXPANSION 6 Number VALVE HVE-16, 7/8"X1/8" FOR R22 THERMOSTATIC CHARGE - VCP.100 COMPLETE WITH SENSOR AND CAPILLARY, A.C. PLANT 7 THERMOSTATIC EXPN VALVE SVE-5 CP-100 16 Number SUITABLE FOR R-22 WITH LENSING ELEMENT, A.C. PLANT 8 SPORLAN MAKE SOLENOID PILOT CONTROL VALVE 6 Number MODEL:180, R22 GAS CONN - 1/4"F COIL RATING 15W,110V AC,PRESSURE=500PSI, A.C. PLANT 9 FIEBIG MAKE P/GS FOR A/C PKG. 760-0-25 KG/CM2, INDEX-1 10 Number Note: (1) Please offer for our required specifications only. (2)Please quote your rate, terms & condition in our prescribed forms & shall be duly filled & signed by bidder with company's round seal. Signature of the bidder Page 3
Taluka: Thasra Dist : Kheda Pin: 388239 Telephone No. 02699-235522 Fax No. 02699-235607 (3)Bidder shall have to fill up the attached Annexure-'A' with Duly Signed & same is to be submitted along with Technical Bid. (4)You shall have to furnish the "Integrity Pact" duly sealed and signed and submit along with technical bid.(annexture-b). (5)Please clearly mention the make/makes for which rates offered by you. (6) Necessary test,guarantee certificate and calibration report are required to be submitted along with the bulk supply. Technical Specifications : -Supply of Spare for AC Plant and Package AC for Stage- 1 WTPS. * For item No:-1 * Combined pressure and Temp. gauge for Freon - 22, 2 1/2 inch dial size, 1/4 inch BSP Flare 0-150 PSI for A/C Plant (Gauge adopter Size:- 1/8 inch (M) NPT X 1/4 inch (M) BSP (F)). * For item No:-2 * Combined pressure and Temp. gauge for Freon-22, 2 1/2 inch dial size,1/4 inch BSP Flare 0-300 PSI for A/C Plant (Gauge adopter Size:- 1/8 inch (M) NPT X 1/4 inch (M) BSP (F)). *For item No:-3* Combined pressure and Temp. gauge for Freon-22, 2 1/2 inch dial size,1/4 inch BSP Flare 0-450 PSI for A/C Plant (Gauge adopter Size:- 1/8 inch (M) NPT X 1/4 inch (M) BSP (F)). *For item No:-4* Diff. pressure switches MP-55 with Thermal Timing Relay, Range: - 5 to 100 PSI, electrical rating 2A, 250 V AC and 0.2 A, 250 V DC, 1/4 inch Flares connection for A/C plant. Signature of the bidder Page 4
Taluka: Thasra Dist : Kheda Pin: 388 239 Telephone No. 02699-235 522 Fax No. 02699-235 607 *For item No:-5* Supply of HIGH/LOW pressure control switches MP-15 1/4 inch Flare SDT connection, permissible test pressure 16 atm.g. for low pressure and 32 atm.g.for high pressure. With electrical rating 10 Amp. Max. And operate on 230 V AC/DC *For item No:-6* Supply of Sporlan make Thermostatic Expansion valve, HVE-16 7/8 inch X 1/8 inch, for R-22, Thermostatic, charge VCP-100 complete with Sensor and capillary, capacity 15 TON for AC Plant. Make :- SPORLAN, U.S.A Model No. :- HVE-16 - VCP-100 (R - 22) *For item No:-7* Supply of Sporlan make Thermostatic expansion Valves SVE-5, CP-100 Suitable for R-22 complete with sensing element & capillary for AC Plant. Make :- SPORLAN, U.S.A Model No. :- SVE - 5 - CP-100 (R - 22) *For item No:-8* Supply of solenoid pilot control valve (1) Make: - Sporlan Valve Co.USA ( 2) Model: - 180, R-22 Gas (3) Connection: - 1/4 inch Flare (4) Coil rating:-15 W, 110 VAC (5) Pressure:-500 PSI. *For item No:-9* Supply of FIEBIG MAKE P/GS FOR A/C PKG. (1) Make:- Fiebig make for Freon - 22 application. (2) Range:- 760 mm Hg. - 0-25 Kg/cm2 (3) Working Temp. :- - 70 to 40 Deg. Signature of the bidder Page 5
Taluka: Thasra Dist : Kheda Pin: 388239 Telephone No. 02699-235522 Fax No. 02699-235607 (2) Process connection:- 3/8" BSP (M) (3) Mounting :- Surface mounting with 120 deg. equal 3 holes. ( Hole Dia:- 5mm) (4) Entry:- Bottom connection with non ferrous internals and in drawn steel housing. (5) Dial size:- 100 mm (6) Accuracy:- +/- 1% of FSD. I/C CHIEF ENGR (C&O) GSECL, WTPS Signature of the bidder Page 6