Battery Separators - 100A

Similar documents
1318/ V BATTERY SEPARATOR

(UNIDIRECTIONAL) & (BIDIRECTIONAL) 24 VOLT, 200 AMP BATTERY SEPARATORS

INTERCONNECT/CONTROLLER

BATTERY DISCONNECT UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES [MM]

24V TO 13.5V FIXED OUTPUT VOLTAGE CONVERTER

PRECISION MOTION CONTROL

PRODUCT SPECIFICATION OUTPUT CURRENT (A) OUTPUT CURRENT TOLERANCE ±7% ±7% ±10% ±10% ±7% 1.8. Units % % % Typ. Typ.

DKG-114 MANUAL AND REMOTE START UNIT

PRODUCT SPECIFICATION C00 Converter. 48/36V to 12V, 20 Amps w/switched Output

Very high efficiency up to 93% Adjustable output voltage

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

Product Specification 12010E00 EQUALIZER AND 12010C00 CONVERTER, 12V TO 24V FAMILY

DPX30-xxDxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power

DPX30-xxSxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; 3.3 to 28 VDC Single Output; 30 Watts Output Power

DPX30-xxWDxx DC-DC Converter Module 10 ~ 40VDC, 18 ~ 75VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power

DPX30-xxWSxx DC-DC Converter Module 10 ~ 40VDC, 18 ~ 75VDC input; 3.3 to 28VDC Single Output 30 Watts Output Power

Product Specification 11020CL0 DC-DC CONVERTER TRAIL CHARGER WITH LOCKOUTS

Maximum Input Current Vin=18V, 100% Load A Vin=24V ma No-Load Input Current

Note1: tested at nominal Vin, full load and at +25 C ambient. Package (3) CTRL Logic (2)

DPX15-xxWDxx Dual Output: DC-DC Converter Module 9.5 ~ 36VDC, 18 ~ 75VDC input; ±5 to ±15 VDC Dual Output; 15 Watts Output Power

Product Specification 120XXE00 EQUALIZER AND 120XXC00 CONVERTER, 12V TO 24V FAMILY

Output Current Input Current Over Load VDC VDC ma ma(typ.) ma(typ.) VDC μf %

Lockout Hysteresis Voltage VDC Maximum Input Current Vin=18V, 100% Load A

Typical efficiency up to 93 % Up to 4 kw power (max. 16 kw) Liquid or convection cooling. CAN bus serial interface. Adjustable output voltage

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter

CAN and Serial Instrumentation

Cascade CD101 Auto-Start Controller. Installation and Operations Manual Sections 40 & 75

OIS21C. Optical smart sensor for hydraulic cylinders. General Description. Features. Applications. Pin Functions. Ordering Information

IMMOBILISER SYSTEM INTRODUCTION

PRODUCT/TEST MANUAL 2C58K37 INSTANTANEOUS OVERCURRENT RELAY

WATT MBH SERIES DC/DC CONVERTERS

Series AM1P-Z 1 Watt DC-DC Converter

Solid-State Relays. Solid-State Relays. Features. Description. Overview

Battery Equalizers & Converters

Electric Flanged PN16 Cast Iron Ball Valve

201A-9 INSTALLATION INSTRUCTIONS. Revision A1 Rapid City, SD, USA, 01/2010

Solid-State Relays. Solid-State Relays. Features. Description. Overview

HAE S 05 W - P HS Series Name Input Output Output Input Ctrl and Assembly Option Voltage Quantity Voltage Range Pin Options

VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S

MBCM-24 MULTIPLE BATTERY CHARGING MODULE (FOR MARINE APPLICATIONS) FEATURES SPECIFICATIONS APPLICATIONS DESCRIPTION & OPERATION ORDERING INFORMATION

POWERBOX Industrial Line PMF20W Series 20W 4:1 Single Output DC/DC Converter Manual. DC/DC Converter Features. Introduction

Product Specification 21XXXE00 EQUALIZER AND 21XXXC00 CONVERTER FAMILY

HAE S 05 - P HS Series Name Input Output Output Ctrl and Assembly Option Voltage Quantity Voltage Pin Options

HALF-BRICK DC-DC CONVERTERS 4:1 ULTRA WIDE INPUT RANGE 100 WATT RAILWAY APPLICATIONS HWB100 SERIES

TG350 User Manual. Manual Revision: Min. FW Revision: Date Released: 09/01/ DYNAGEN Technologies Inc

HAE S 05 W - P TH HS PART NUMBER STRUCTURE Page 1. P-DUKE Technology Co., Ltd.

HAE S 05 - P TH HS PART NUMBER STRUCTURE Page 1. P-DUKE Technology Co., Ltd.

Output Current Input Current Over Voltage. VDC VDC ma ma(typ.) ma(typ.) VDC μf % MKZI10-24S

Packaging (1) Package

2:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 90% Six-Sided Continuous Shield Available as Power Module (RPM30-E)

EPIC Hermetic Sealed DC and AC Contactor Amp Power Switching RoHS Compliant, all date codes

RVS-DN Digital Reduced Voltage Motor Starter

Output Current Input Current Reflected Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S033

Features. Regulated Converters. RP20-F 20 Watt 2 x 1 Single & Dual Output. RP20- _F/ Package 4) Control Logic (3) DC/DC Converter

SPECIFICATIONS UPS Triple Output 13.6VDC/213W, 48VDC/153W, 48VDC/39W

Power Supplies. SDN-C Compact DIN Rail Series

1 second start up, no external components 220µF <1 second start up + diode protection circuit 6800µF

Drop-in Alternative to Tyco/Kilovac* 500+ Amp EV200, plus a lot more (Compare Products) RoHS Compliant, all date codes

DC-DC CONVERTERS 4:1 WIDE INPUT RANGE UP TO 9 WATTS SINGLE AND DUAL OUTPUT, SIP PACKAGE SWB9 SERIES

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

R-78AA-0.5 INNOLINE. Features. 0.5 AMP SMD Single Output. Derating-Graph (Ambient Temperature) DC/DC-Converter

ISTEK-C A 750V DC Contactor

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

Output Current Input Current Reflected Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S033

4:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 88% Six-Sided Continuous Shield Available as Power Module (RPM30-EW)

2:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 87% Low Profile, 10.2mm Height Over Current Protection

MP V, 1A, Li-lon, Linear Battery Charger with 10mA High Voltage LDO

REVISED ATM72 Auto Transfer Module

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

LANC245.1W12. DC/DC Converter VDC Input 5.1 VDC Output at 2.4A. Features:

Series AM2D-Z 2 Watt DC-DC Converter

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ELECTRICAL

RVS-DX Digital Reduced Voltage Motor Starter

Model Number Structure

S24SP series 40W Single Output DC/DC Converter

Series AM2D-Z 2 Watt DC-DC Converter

Load (2) Single or Dual

GENSET CONTROL MODULE A121H / A241H. User selectable time delays for engine start and engine stop (cool down).

Industrial Power Supplies

2:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 91% Six-Sided Continuous Shield Available as Power Module (RPM60-G)

Power Supplies POWER SUPPLIES TRANSIENT VOLTAGE SUPPRESSORS POWER LINE FILTERS. AC to DC Power Supply Units. AC to 24VDC Regulated Primary Switching

B70SR12424A/B/C/D 12V Output DC/DC Converter, Box Type Package

Output Current Input Current Reflected Ripple. Efficiency (typ.) (Range) VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf % MTQZ50-72S05

HILLSTONE DC LOAD BANK

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

Pantera Electronics LED Gauge Lamp Installation Manual

Efficiency(1) Max. Capacitive. Package(3) CTRL Logic(2) Single

CONTROL, PROTECTION AND VISUALIZATION ELECTRONIC MANUAL CEN- TRALITE FOR GENERATING SETS CMD2.0

Output Current Input Current Reflected Ripple. VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf %

DMC mA Positioner

B70SR24125A/B/C/D 24V Output DC/DC Converter, Box Type Package

HGM72 Automatic Generator Module OPERATING MANUAL Smartgen Electronic

3A Switching Charger, 2.4A Boost and Fuel Gauge in One ESOP8 with Single Inductor

Safety Standards. Model Number:

(typ.) (Range) Load

HGM1750 Genset Security Module USER MANUAL Smartgen Technology

SDM72 Start on Demand Modules

702 AUTOMATIC START MODULE OPERATING INSTRUCTIONS

Power Supplies. POWER SUPPLIES AC to 24VDC Regulated Primary Switching. TRANSIENT VOLTAGE SUPPRESSORS Industrial Design MINI UNIVERSAL MOUNT

CENTRAL BATTERY UNIT. Installation and maintenance instructions TKT3122

Transcription:

Stock No. Sure Power Part Number Description 80000 1314 Uni-Directional 80002 1315 Bi-Directional Features: Battery separator modules with integrated relay for 12V systems Monitors both the main and auxiliary battery banks If main battery (for 80000) or either battery bank (for 80002) is above connect threshold, the relay connects the two banks together If main battery (for 80000) or either batteries (for 80002) are below disconnect threshold, the unit will open the relay Connect threshold is set to a nominal voltage of 13.2V, which would only be reached when charging system is operating Disconnect voltage is set to a nominal 12.7V, which is near the full charge resting voltage of the batteries, which causes the relay to be opened shortly after engine is stopped, attempting to preserve 100% of starting battery capacity for engine cranking When engine is started, the start signal causes controller to check if the auxiliary battery is within about 1V of the main battery, if so, relay contact is closed, providing starter system with max. battery voltage available Quick connect tabs are 1/4 and spacing is compatible with Delphi P/N 12040949 LAMP Powered when start signal input has caused relay to close. This output can source up to 250mA to an incandescent lamp. For LED type indicator, see MAXIMUM RATINGS, START LAMP drive current START SIGNAL When power is applied, relay closes if Aux. Bat is no less than 0.85 volts below Main Bat. GROUND Ground connection AUX. BAT Draws power from main battery or aux. battery, whichever has the higher voltage Draws power from main battery or aux. battery, whichever has the higher voltage

ENVIRONMENTAL SPECIFICATIONS: Control module is encapsulated in epoxy, relay is water resistant. Characteristics Parameter Operational Temperature Range (Control) -40 F to 185 F (-40 C to 85 C) Operational Temperature Range (Relay) -18 F to 118 F (-28 C to 48 C) ELECTRICAL MAXIMUM RATINGS: Maximum ratings establish the maximum electrical rating to which the unit may be subjected without damage. Characteristics Symbol Parameter Unit Input Voltage 16 V VINMAX Standoff Voltage 24 V VSO Time at Standoff tso Continuous Continuous Relay current 100 A IR,MAXC Inrush Relay current 400 A IR,MAXI START LAMP drive current 250 ma ILAMP ESD Vesd ±8kV contact ±8kV air V Notes Damage to relay may occur if repeatedly operated above 16V 5-minute duration. Applies to AUX BATT, MAIN BATT and START SIGNAL terminals only Control is protected from continuous operation at 40V 30 seconds on, 6 minutes off duty cycle Protected from short circuits on output-tested at 16V This output is designed for an incandescent lamp. A current-limiting resistor must be used in series with an LED indicator (1k-Ohm, 1/2 W recommended) Ref. SAE J1113-13. All terminals in any combination

ELECTRICAL CHARACTERISTICS: Unless otherwise stated, conditions apply to a full operational temperature range and full voltage range (9V to 16V) Note: typical voltage settings have ± 2% tolerance All terminals protected against reverse polarity except reversal of one of the battery polarities. (Relay is not current limited. Connecting batteries of opposite polarity will damage relay) Characteristics Symbol MIN TYP MAX Unit Notes Normal Input Voltage VIN 10 16 V Proper relay operation not guaranteed below 10V Contact life 50,000 Cycles 100A resistive load Connect Voltage VCON 13.2 V Nominal minimum voltage required at main battery terminal for attached relay to be energized Disconnect Voltage VDCON 12.7 V Nominal maximum voltage required at main battery terminal for attached relay to be energized Quiescent Current IQUES 1.8 ma 13.0V, relay off, Start Signal input open or grounded Relay drive current IRELAY.75 A START LAMP output voltage VLAMP Battery voltage - 2.2V V 2.2V is typical voltage drop from Main Battery to the Start Lamp output (Battery voltage being the higher of the two battery voltages). START SIGNAL threshold voltage VSST 58% of Battery V Nominal minimum voltage required on START SIGNAL input for the input to activate Connect debounce tcd 14 S When the battery voltage rises above the connect voltage and the relay closes, this is the minimum amount of time it will stay closed, regardless of the battery voltages Disconnect debounce tdd 10 S When the battery voltage falls below the disconnect voltage and the relay opens, this is the minimum amount of time it will stay open, regardless of the battery voltages

TRANSIENT IMMUNITY/EMMISIONS Characteristic Level Notes Inductive Load Switching +400V/-600V Ref. SAE J1455, Section 4.11.2.2.2 Rev 8/94 Mutual Coupling ±300V Ref. SAE J1455, Section 4.11.2.2.2 Rev 8/94 Load Dump 100V Ref. SAE J1455, Section 4.11.2.2.2 Rev 8/94 ISO Immunity Per standard 1 ISO 7637-2:2004 ISO Emmissions Per standard 1 ISO 7637-2:2004 1Sufficient to apply E mark. RADIATED EMISSIONS Characteristic Level Notes Radiated Emissions Narowband 30MHz to 1GHz Per standard 2 ISO 13766:1999, section 6.5 EN 13309:2000, section 4.6 EU Directive 72/245/EEC as amended Radiated Emissions Broadband 30MHz to 1GHz Per standard 2 ISO 13766:1999, section 6.4 EN 13309:2000, section 4.5 EU Directive 72/245/EEC as amended 2Sufficient to apply CE marking.

CONNECTION DIAGRAM