Safety switches for hinged doors

Similar documents
Safety switches for hinged doors

Position switches FR series

Position switches FR series

Safety switches for hinges

Position switches FC series

Position switches FD series

Microswitches M series

Safety switches with separate actuator

Safety switches with separate actuator

Single foot switches PX and PA series

Prewired position switches FF series

Single foot switches PX and PA series

Safety rope switch without reset for simple stop

Safety rope switches with reset for emergency stop

Safety rope switch with reset for emergency stop

Switches with manual reset

Prewired position switches FF series

Rope safety switches with reset for emergency stop

FL series position switches

LR-LX-LK-LW Safety Switches with separate actuator

Microswitches MK series

Safety switches with solenoid and separate actuator

LK Position Switches TECHNICAL DATASHEET.

Safety switches with solenoid and separate actuator

SFS-UFS Single Foot Switches

Microswitches MK Series

Safety switches with solenoid and separate actuator

Microswitches MK series

Switches in conformity with ATEX directive

Switches in conformity with ATEX directive

Single foot switches - PX and PA series

Safety switches with solenoid and separate actuator

Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66

Safety Limit Switches

Limit Switches - Safety Type Plastic Body IP65 and Metal Body IP66

Safety switches with solenoid and separate actuator

Limit Switches - Limit Type Plastic Body IP65

Safety switches with solenoid and separate actuator

Limit switches. 7 Page 71. Presentation. OsiSense XC Basic Compact design, plastic, with reset knob, types XCNR and XCNTR. b XCNR.

Limit Switches - Limit Type (PS21L) Metal Body IP66

Limit Switch - Prewired Type Metal Body

Limit Switches - Limit Type Plastic Body IP65

Double insulated, types XCK-P and XCK-T. With head for linear movement (plunger) operators

Limit Switches - Limit Type (PS31L) Plastic Body IP65

Solenoid interlocks AZM 190 range. 128 Schmersal ,3 4,5 M20 17,5 23,5

Limit Switches - Limit Type (PS42L) Plastic Body IP65

Miniaturized limit switches

Pre wired limit switches

Selection diagram. Actuators. Body. Contact blocks. Cable entry A A S1 B B 13. Thermoplastic

Solenoid interlocks AZM 170 range. 98 Schmersal 22 8,2 60. ø4,2. ø Pg 11

Metal limit switches are made of zinc alloy and have a degree of protection of IP67 and NEMA Type 4, 4X.

F E - Electromagnetic Safety Switch With Separated Actuator. 1 Code Construction. Casing: P: Plastic casing

Installation and Operating Instructions

LS Series Limit Switches. Short Form Catalogue AC1300 ABB

Installation and Operating Instructions

Hinged Safety Door Switch

Automation - Lift - Handling System - Atex

Solenoid interlocks AZM 161 range Schmersal. a 5,5. Pg11/M16x1,5

Comepi S.r.l. reserves the right to modify its products and to change any details in this pubblication at any time without prior notice.

Technical data. Standards: IEC/EN BG-GS-ET-15

Control Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België

XCKJ390559H29EX limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx

Gross Automation (877)

Safety Limit Switch

Selection diagram. Actuators. Body. Contact blocks. Cable entry A A S1 B B 13. Thermoplastic

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

Technical data. Standards: IEC/EN ; EN ISO ; EN 1088; BG-GS-ET-19

Limit Switches 1-1 thru Safety Switches 2-1 thru Index 3-1

D4B- N. Safety Interlock Switches. Safety Limit Switch. Specifications. Standards and EC Directives. Certified Standard Ratings D4BN

AF40... AF96 3-pole contactors Technical data

Safety Switches with Separate Actuator SKC

Compact plastic limit switches with positive opening mechanism

Selection diagram. Actuators. Bodies. Contact blocks. Cable entry AB BB CB. Thermoplastic

AZM 161SK 12/12RKED/TU 024

XCKP2145P16 limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - M16

Limit Switch D4D- N. Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark

Limit switches. 6 Thermoplastic roller lever 1 direction of actuation SEN TRONIC AG. Presentation

Recommended use With its standard enclosure, the ENM2 limit switch can be used universally in all industrial and safety applications.

SG-B1 SERIES / SG-A1 SERIES

Compact plastic limit switches with positive opening mechanism

Selection diagram. Actuators. Body. Contact blocks. Cable entry A A S1 B B 13. Thermoplastic

Standard Interlock Safety Switches

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

Ordering details. Approval. Classification. Global Properties :18:33h. Solenoid interlock / AZM 161

Safety-door Switch. Ordering Information

Limit switches 3. Page 92. Page 92

Datasheet - AZ ZUEK Safety switch with separate actuator / AZ 3350

Solenoid interlocks AZM 415 range. 134 Schmersal 29,5 6,5 24,7. 8,6 Pg 13,5 46,5 24,5

FOOT SWITCHES

Modular multiple foot switches PC series

Manual Reset Limit Switch

Standard Interlock Safety Switches

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Datasheet - TV8S /20Z Safety switch for hinged guards / Hinge safety switch / TV8S 521

Pendant control stations 6

OsiSense. XC Basic Limit Switches XCMN, XCKN, XCNT

Modular multiple foot switches PC series

HS5D Miniature Interlock Switches

Rotary limit switches FCR FGR series

blocks Interconnection fuses &

Transcription:

4 Safety switches for hinged doors Selection diagram FR FM FX FZ FK 5 18 7 9 snap action overlapped CONTACT BLOCKS 20 21 22 33 34 1NO+ CONDUIT ENTRIES Threaded conduit entries (standard) With cable gland assembled With M12 plastic connector assembled and wired With M12 metal connector assembled and wired product option accessory sold separately page 4/49 General Catalog 18

Safety switches for hinged doors 4 Code structure Housing FR FM FX FZ polymer housing, one conduit entry metal housing, one conduit entry polymer housing, two conduit entries metal housing, two conduit entries 18, 5, snap action 7, overlapped 9, 20 1NO+, 21, 22, 33, 34, Attention! The feasibility of a code number does not mean the effective availability of a product. Please contact our sales office. FR 1896-XGM2K70 Threaded conduit entry A M1 M2 M3 Preinstalled cable gland or connectors K21 K40 PG 13,5 (standard) PG 11 (only for FR-FX housing) M16x1,5 (only for FR-FX housing) M20x1,5 no cable gland or connector (standard) with assembled cable gland suitable for Ø 6 to Ø 12 mm cables range with M12 metal connector assembled and wired, 8 poles (only for contact blocks 20, 21, 22)...... For the complete list of all combinations, please contact our technical office. 1/2 NPT (only for FR housing) External metallic parts zinc-plated steel (standard) X stainless steel Contacts type silver contacts (standard) G silver contacts gold plated 1 µm Housing FK polymer housing, one conduit entry 33, 34, FK 3396-XGM1K22 Preinstalled cable gland K22 K26 no cable gland (standard) with assembled cable gland suitable for Ø 5 to Ø 10 mm cables range with assembled cable gland suitable for Ø 3 to Ø 7 mm cables range External metallic parts zinc-plated steel (standard) X stainless steel Threaded conduit entry PG 11 (standard) M1 M16x1,5 Contacts type silver contacts (standard) G silver contacts gold plated 1 µm General Catalog 18 page 4/50

4 Safety switches for hinged doors Technical data Housing Housing type FR, FX and FK made of glass-reinforced polymer, self-extinguishing, shock-proof thermoplastic resin Housing type FM and FZ made of metal, coated with baked epoxy powder. FR, FM and FK series one conduit entry FX and FZ series two conduit entries Protection degree: IP67 Main data Metal housing or polymer housing, from one to two conduit entries Protection degree IP67 9 contact blocks available Stainless steel actuator M12 assembled connector versions Silver contacts gold plated versions Stainless steel external parts versions Markings and quality marks: Approval IMQ: Approval UL: E131787 Approval EZU: 1010151 EG610 (FR-FX-FK series) EG609 (FM-FZ series) General data Ambient temperature: Version for operation in ambient temperature from -40 C to +80 C on request from -25 C to +80 C Max operating frequency: 3600 operations cycles 1 /hour Mechanical endurance: 1 million of operations cycles 1 Max actuating speed: 180 /s Min. actuating speed: 2 /s (1) One operation cycle means two movements, one to close and one to open contacts, as foreseen by IEC 947-5-1 standard. Cross section of the conductors (flexible copper wire) 20, 21, 22, 33, 34: min. 1 x 0,34 mm 2 (1 x AWG 22) max. 2 x 1,5 mm 2 (2 x AWG 16) 5, 7, 9, 18: min. 1 x 0,5 mm 2 (1 x AWG 20) max. 2 x 2,5 mm 2 (2 x AWG 14) In conformity with standards: IEC 947-5-1, IEC 337-1, EN 60947-5-1, CEI EN 60947-5-1, CEI 17-45, IEC 204-1, EN 60204-1, CEI 44-5, EN 1088, EN ISO 12100-1, EN ISO 12100-2, IEC 529, EN 60529, CEI 70-1, NFC 63-140, VDE 0660-200, VDE 0113, CENELEC EN 50013, BG-GS-ET-15. Approvals: IEC 947-5-1, UL 508. In conformity with requirements requested by: Low Voltage Directive 73/23/EEC and subsequent modifications and completions. Machinery Directive 98/37/EEC. Electromagnetic Compatibility 89/336/EEC and subsequent modifications and completions. Positive contact opening in conformity with standards: IEC 947-5-1, EN 60947-5-1, CEI EN 60947-5-1, VDE 0660-206. For the correct installation of all articles, please see Utilization requirements chapter, from page 6/1 to page 6/4. Electrical data Utilization categories without connector Thermal current (Ith): 10 A Rated insulation voltage (Ui): 500 VAC 600 VDC 400 VAC for contact blocks 20, 21, 22, 33, 34 Protection against short circuits: fuse 10 A 500 V type am Pollution degree: 3 Alternate current: AC15 (50...60 Hz) Ue (V) 250 400 500 Ie (A) 6 4 1 Direct current: DC13 Ue (V) 24 125 250 Ie (A) 6 1,1 0,4 with 4 or 5 poles M12 connector with 8 poles M12 connector Thermal current (Ith): 4 A Rated insulation voltage (Ui): 250 VAC 300 VDC Protection against short circuits: fuse 4 A 500 V type gg Pollution degree: 3 Thermal current (Ith): 2 A Rated insulation voltage (Ui): 30 VAC 36 VDC Protection against short circuits: fuse 2 A 500 V type gg Pollution degree: 3 Alternate current: AC15 (50...60 Hz) Ue (V) 24 120 250 Ie (A) 4 4 4 Direct current: DC13 Ue (V) 24 125 250 Ie (A) 4 1,1 0,4 Alternate current: AC15 (50...60 Hz) Ue (V) 24 Ie (A) 2 Direct current: DC13 Ue (V) 24 Ie (A) 2 page 4/51 General Catalog 18

Safety switches for hinged doors 4 Description These safety switches have been designed to control gates or guards that protect the hazardous parts of machines. They are very sensitive and positively open the contact block after few rotation degrees, sending the stop signal immediately. The head adjustable in 90 steps allows their installation in four different positions. Available with polymer or metal housing, with protection degree IP67. Its special shape allows to use this type of switches also in those areas where dust and dirt could block working of normal safety switches with separate actuator. Rotating heads Removing the four fastening screws, in all switches, it is possible to rotate the head in 90 steps. Installation examples Data type approved by IMQ and EZU Rated insulation voltage (Ui): 500 VAC 400 VAC for contact blocks 20, 21, 22, 33, 34 Thermal current (Ith): 10 A Protection against short circuits: fuse 10 A 500 V type am Protection degree: IP67 MV terminals (screw clamps) Pollution degree 3 Utilization category: AC15 Operation voltage (Ue): 400 VAC (50 Hz) Operation current (Ie): 3 A Forms of the contact element: Zb, Y+Y, Y+Y+X, Y+Y+Y, Y+X+X Positive opening of contacts on contact block 5, 7, 9, 18, 20, 21, 22, 33, 34 In conformity with standards: EN60947-1, EN 60947-5-1 and subsequent modifi cations and completions, fundamental requirements of the Low Voltage Directive 73/23 EEC and subsequent modifi cations and completions. Please contact our technical service for the list of type approved products. Data type approved by UL Utilization categories Q300 (69 VA, 125-250 VDC) A600 (720 VA, 120-600 VAC) Data of the housing type 1, 4X (indoor use only), 12, 13 In conformity with standard: UL 508 For all contact blocks use 60 or 75 C copper (Cu) conductor and wire size No. 12-14 AWG. Terminal tightening torque of 7,1 Lb-In. Please contact our technical service for the list of type approved products. General Catalog 18 page 4/52

4 Safety switches for hinged doors Dimensional drawings Contacts type: polymer housing polymer housing polymer housing R = snap action L = LO = overlapped 18 L FR 1896 FX 1896 5 R FR 596 FX 596 7 LO FR 796 FX 796 9 L FR 996 FX 996 20 L FR 2096 1NO+ FX 2096 1NO+ 21 L FR 2196 FX 2196 22 L FR 2296 FX 2296 33 L FR 3396 FX 3396 FK 3396 34 L FR 3496 FX 3496 FK 3496 Min. force 0,15 Nm (0,4 Nm ) 0,15 Nm (0,4 Nm ) 0,15 Nm (0,4 Nm ) Accessories See page 5/1 Items with code on the green background are available in stock How to read travel diagrams NC opening Example diagram Positive opening travel Max travel Closed contact Open contact NO closing All measures in the diagrams are in degrees IMPORTANT: In safety applications it is necessary to activate the switch at least up to the positive opening point indicated in the diagrams with the symbol. Operate the switch at least with the positive opening force, indicated between brackets, below each article, next the value of minimum force. All measures in the drawings are in mm page 4/53 General Catalog 18

Safety switches for hinged doors 4 Contacts type: metal housing metal housing R = snap action L = LO = overlapped 18 L FM 1896 FZ 1896 5 R FM 596 FZ 596 7 LO FM 796 FZ 796 9 L FM 996 FZ 996 20 L FM 2096 1NO+ FZ 2096 1NO+ 21 L FM 2196 FZ 2196 22 L 33 L 34 L Min. force FM 2296 FZ 2296 FM 3396 FZ 3396 FM 3496 FZ 3496 0,15 Nm (0,4 Nm ) 0,15 Nm (0,4 Nm ) General Catalog 18 page 4/54