RS SERIES. Two Stage Progressive Gas Burners FIRING RATES

Similar documents
RS/M SERIES. Modulating Gas Burners FIRING RATES

RS/1 SERIES. One Stage Gas Burners RS 34/1 MZ RS 44/1 MZ kw kw GAS

RS/E-EV MZ SERIES. Modulating Gas Burners FIRING RATES

GULLIVER BSD SERIES. Low NOx Two Stage Gas Burners FIRING RATES. BS1D 16/19 52 kw BS2D 35/40 91 kw BS3D 65/ kw BS4D 110/ kw.

RS Series Two Stage Progressive Gas Burners

GULLIVER BS SERIES. Low NOx One Stage Gas Burners FIRING RATES. BS kw BS kw BS kw BS kw.

RL/M BLU SERIES. Low NOx Modulating Light Oil Burners FIRING RATES. LOW NOx T. M 190/ kw M 223/ kw

PRESS G SERIES. Two Stage Light Oil Burners FIRING RATES

RIELLO 40 FS SERIES. One Stage Gas Burners FIRING RATES. FS kw FS kw FS kw FS kw FS kw FS kw GAS

TECHNICAL DATA LEAFLET GAS. RS/1 Series. One Stage Gas Burners. RS 34/1 MZ kw RS 44/1 MZ kw.

ONE STAGE GAS BURNERS RS/1 SERIES RS 28/ kw RS 34/1 MZ kw RS 38/ kw RS 44/1 MZ kw

RIELLO 40 GS SERIES. One Stage Gas Burners FIRING RATES. S kw S kw S kw S kw

TWO STAGE PROGRESSIVE GAS BURNERS

PRESS P/N - P/N ECO SERIES

TWO STAGE GAS BURNER GULLIVER RSD SERIES RS5D 160/ kw

TWO STAGE GAS BURNERS

TWO STAGE PROGRESSIVE AND MODULATING GAS BURNERS RIELLO 40 GS/M SERIES GS 10/M 22/ kw GS 20/M 43/ kw

ONE STAGE GAS BURNERS RDBS SERIES

ONE STAGE GAS BURNER GULLIVER RSF SERIES RS5F kw

RES G MRBLU SERIES. Low NOx One Stage Light Oil Burners FIRING RATES. LOW NOx LIGHT OIL

LOW NOx TWO STAGE GAS BURNERS GULLIVER BSD SERIES BS1D 16/19 52 kw BS2D 35/40 91 kw BS3D 65/ kw BS4D 110/ kw

TWO STAGE LIGHT OIL BURNERS PRESS G SERIES

DB Series. Technical Data Leaflet. Industrial Dual Block Oil, Gas and Dual Fuel Burners. Industrial TS0086UK00

RIELLO 40 F SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL. F kw F kw F kw

RS/E BLU Series. Technical Data Leaflet. Low NOx Modulating Gas Burners. Low NOx Gas TS0087UK00

RDB SERIES. One Stage Light Oil and Kerosene Burners FIRING RATES LIGHT OIL

CODE MODEL TYPE PRESS GW 605 T80

KOLHAPUR FOUNDRY & ENGINEERING CLUSTER

CODE MODEL TYPE G3BF 490T G5BF 492T G5BF 489T53

Oil, gas and dual fuel burners. Burner series

Oil, Gas and Dual Fuel Burners

Kerosene - oil burner

Data sheet: Wilo-Yonos MAXO 40/0,5-16

Installation- and maintenance instruction BENTOFLEX ST 108 PL

Installation- and maintenance instruction ST120 S75/21

Light oil - kerosene burner

Installation- and maintenance instruction BENTOFLEX ST120KAV

product Digital dual fuel burners Weishaupt dual fuel burners WGL30-C and WGL40-A ( kw) Information on compact burners

Oil - kerosene burner

product Information on oil, gas and dual fuel burners Industrial burners 1,000 11,700 kw flexible and reliable

Installation- and maintenance instruction B80-2/3

GREENOx BT LOW RETURN TEMPERATURE DUAL BT WITH TILED BOILERS. GREENOx BT COND LOW RETURN TEMPERATURE WITH CONDENSER

Doing more for clean environment and energy saving

Valve monitoring system VDK 200 A S02

Emprendimiento Fénix Product Catalogue

GAS BURNERS BLU 3000 PR BLU 4000 PR

product Digital combustion technology Weishaupt gas burners, WG10 to WG40 ( kw) Information on compact burners

Data sheet: Wilo-Stratos-D 32/1-8

Data sheet: Wilo-Stratos-Z 25/1-8

3 Edition Product brochure GB AGA

822 NOVAMIX GAS FLOW RATE ADJUSTMENT AS A FUNCTION OF THE AIR FLOW GAS/AIR RATIO 1:1 DOUBLE AUTOMATIC SOLENOID SHUT-OFF VALVE

3 Specification Magneta Smedegaard

MBC-300-SE MBC-700-SE MBC-1200-SE MBC-300-N MBC-700-N

Weishaupt gas burners Sizes 30 to 70 Version NR (NO x reduced)

available in battery up to 4 units for a total of 560 kw

QUOTATION BLADE 7 LX. Product code GEAL6S2BAA

REX/REX F/REX K/REX K F REX DUAL/REX DUAL F

Valves. Rapid opening and closing solenoid valves VMR (E1110 rev /11/2012)

PRESSURIZED STEEL BOILER WITH REVERSED FLAME

GasMultiBloc Combined regulator and safety valve Infinitely variable air/ gas ratio control mode MBC-300-VEF MBC-700-VEF MBC-1200-VEF

Mobile Diesel Heaters GRY-D / GRY-I Service Training Course

Data sheet: Wilo-Stratos-D 50/1-12

Whad 0.8, 1, 1.5 kva. Manuel d installation Installation manual. Part. LE05733AA-07/12-01 GF

STAINLESS STEEL CONDENSING GENERATOR RANGE RATED. MODEL Heat thermal input 65,5. 62,0 Heat output (80 C/60 C) 14,0

LKS 160 FOR AIR DAMPERS ON MULTI-STAGE AND MODULATING BURNERS

OIL BURNERS MAIOR P 45 AB. techniques for energy saving MODEL. HYDRAULIC SYSTEM 220/380 V 60 Hz LB

Tightness control TC. Product brochure GB Edition 12.10

Data sheet: Wilo-Stratos PICO 25/1-6

Gas burner Dual fuel burner. Gas burner. Series RG GG MG. Dual fuel burner. Series MK

Oil, Gas and Dual Fuel Monoblock Burners

Installation- and maintenance instruction B20KA/K

ECONOMATIC REX/REXF REX/REXF DUAL STR

MODEL B360 E ILLUSTRATED PARTS BREAKDOWN UNIT 1. From Serial Number: Untill Serial Number: Edizione 2010 Rev. A. Cod

Data sheet: Wilo-Stratos PICO 25/

product Digital combustion technology Weishaupt oil burners, WL10 to WL40 ( kw) Information on compact burners

CATALOGUE A complete range of burners for all fuels MONOBLOCK kw DUOBLOCK kw

MODEL INFORMATION CANNED MOTOR PUMP TYPE CAM HERMETIC

XL9 E-S Serial number N for XL9 E Edition 2005

Weishaupt Monarch oil burners Sizes 1 and 3 1/2002 GB

VALUPAK. Packaged gas burners

X-Series Spare Parts List

4 Specification Magneta Smedegaard twin pumps

Installation- and maintenance instruction B20K-2

Data sheet: Wilo-TOP-S 40/10 (1~230 V, PN 6/10)

Proportional controlling element

E Series CE Approved Intermittent Pilot Ignition Control

Weishaupt Monarch oil burners Sizes 5 to 11 1/2002 CA

burners with or without fan. It conforms to EN C). APPROVAL EU type test approval as per EU Gas Appliance Directive.

VICTRIX PRO Wall-hung modular condensing boiler for heating only

Data sheet: Wilo-TOP-S 40/4 (1~230 V, PN 6/10)

VARIABLE SPEED WATER BOOSTER SETS WITH MULTISTAGE VERTICAL ELECTRIC PUMPS FLOW RATES UP TO 400 m 3 /h. 50 Hz GHV30 GHV40 SERIES

MBC-300-SE MBC-700-SE MBC-1200-SE MBC-300-N MBC-700-N

Weishaupt Monarch oil burners Sizes 5 to 11 1/2002 GB

LKS 170 FOR AIR DAMPERS ON SINGLE, DUAL STAGE AND MODULATING BURNERS

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS

S4562C 1085 COMBI BOARD APPLICATION. Contents PRODUCT HANDBOOK. General

VP23. 3-way proportional pressure control valve Directly-controlled seat valve with μp-driven pressure control G 1/4 to G 3/4 Nominal diameter 8/16

Thermo 90 S.21 Diesel - 24 Volt

Weishaupt oil burners Sizes 30 to 70 1/2003 CA

product WM 30 for gas, oil, and dual-fuel WM 30 monarch burners ( kw) powerful and versatile Information on gas, oil, and dual-fuel burners

Transcription:

The RS burners series covers a firing range from 44 to 2290 kw, and it has been designed for use in low or medium temperature hot water boilers, hot air or steam boilers, diathermic oil boilers. Operation is two stage progressive ; the burners are fitted with a microprocessor-based burner safety control box which supplies indication of operation and diagnosis of fault cause. The elevated performance of the fans and combustion head, guarantee flexibility of use and excellent working at all firing rates. The exclusive design ensures reduced dimensions, simple use and maintenance. Optimisation of sound emissions is guaranteed by the special design of the air suction circuit and by incorporated sound proofing material. A wide range of accessories guarantees elevated working flexibility. RS 34 MZ 45/125 390 kw RS 44 MZ 80/203 550 kw RS 50 115/290 600 kw RS 64 MZ 150/400 850 kw RS 70 192/465 814 kw RS 100 232/698 1163 kw RS 130 372/930 1512 kw RS 150 300/900 1850 kw RS 190 470/1279 2290 kw GAS FIRING RATES Useful working field for choosing the burner 1st stage operation range Test conditions conforming to EN676 Temperature: 20 C Pressure: 1013,5 mbar Altitude: 0 m a.s.l. 435

FIRING RATES RS 150 Useful working field for choosing the burner 1st stage operation range Test conditions conforming to EN676 Temperature: 20 C Pressure: 1013,5 mbar Altitude: 0 m a.s.l. 436

Overall dimensions (mm) RS 34 MZ - 44 MZ RS 50 MODEL A D E F - F(1) H I L M N O S V u RS 34 MZ 442 422 508 216-351 140 305 138 1 1/2 84 780-177 u RS 44 MZ 442 422 508 216-351 152 305 138 1 1/2 84 780-177 u RS 50 476 474 580 216-351 152 352 164 1 1/2 108 810 367 168 (1) dimension with extended head RS 64 MZ RS 70-100 - 130-150 - 190 GAS MODEL A B C D E F - F(1) H I L M N O - O(1) V u RS 64 MZ 533 300-490 640 250-385 179 352 222 2 134 870 - - 221 u RS 70 511 296 215 555 840 250-385 179 430 214 2 134 1161-1296 221 u RS 100 527 312 215 555 840 250-385 179 430 214 2 134 1161-1296 221 u RS 130 553 338 215 555 840 280-415 189 430 214 2 134 1161-1296 221 u RS 150 675 370 305 590 840 280-415 189 435 214 2 134 1180-1315 221 u RS 190 681 366 315 555 872 370-520 222 430 246 2 150 1328 - - 262 (1) dimension with extended head 437

Overall dimensions (mm) - BOILER MOUNTING FLANGE MODEL D1 D2 Ø u RS 34 MZ 160 224 M8 u RS 44 MZ 160 224 M8 u RS 50 160 224 M8 u RS 64 MZ 185 275-325 M12 u RS 70 185 275-325 M12 u RS 100 185 275-325 M12 u RS 130 195 275-325 M12 u RS 150 195 275-325 M12 u RS 190 230 325-368 M16 PACKAGING Z X(1) Y MODEL X (1) Y Z kg u RS 34 MZ 1000 485 500 32 u RS 44 MZ 1000 485 500 33 u RS 50 1200 502 520 41 u RS 64 MZ 1200 580 520 42 u RS 70 1405 700 660 70 u RS 100 1405 700 660 73 u RS 130 1400 700 660 76 u RS 150 1400-1420 1000 660 110 u RS 190 1400-1420 1000 660 115 (1) dimension with standard and extended head 438

Specification DESIGNATION OF SERIES Series: R Fuel: S SP L LS N Natural Gas LPG Light oil Light oil/methane Heavy oil Size Setting: /1 Single stage... Two stage /M Modulating Emission:... Class 1 EN267 - EN676 MZ Class 2 EN267 - EN676 BLU Class 3 EN267 - EN676 MX Class 1 EN267 Class 3 EN676 Head length: TC standard head TL extended head Flame control system: FS1 Standard (1 stop every 24 h) FS2 Continuous working (1 stop every 72 h) Electrical supply to the system: 1/230/50 1/230V/50Hz 1/220-230/50-60 1/220-230V/50-60Hz 3/230/50 3/230V/50Hz 3/400/50 3N/400V/50Hz 3/230-400/50 3/230V/50Hz - 3N/400V/50Hz 3/220/60 3/220V/60Hz 3/380/60 3N/380V/60Hz 3/220-380/60 3/220V/60Hz - 3N/380V/60Hz 3/220-400/50-60 3/220-230V/50-60Hz 3/380-400V/50-60Hz GAS Auxiliary voltage: 230/50-60 230V/50-60Hz 220-230/50-60 220-230V/50-60Hz 110/50-60 110V/50-60Hz ID: Differential switch R S 130 TC FS1 3/230-400/50 230/50-60 BASIC DESIGNATION EXTENDED DESIGNATION 439

Specification STATE OF SUPPLY RS 34 MZ - 44 MZ models Monoblock forced draught gas burner with two stage operation, fully automatic, made up of: - Air suction circuit with sound proofing material - High performance fan with straight blades - Air damper for air flow setting and butterfly valve for regulating fuel output on 1 st and 2 nd stage controlled by a servomotor with variable cam - Starting motor at 2800 rpm, single-phase / 220-230V / 50-60Hz or three-phase / 380-400V / 50-60Hz - Combustion head, that can be set on the basis of required output, fitted with: - stainless steel end cone, resistant to corrosion and high temperatures - ignition electrodes - ionisation probe - gas distributor - flame stability disk - Exclusive patented HCS (Housing Cooling System) with high thermal insulation and air circulation with continuous air volume refresh for an active cooling system and avoid heat transfer to the electrical component housing - Minimum air pressure switch stops the burner in case of insufficient air quantity at the combustion head - Microprocessor-based burner safety control box, with diagnostic functions - Plug and socket for electrical connections accessible from the external of the cover - Burner on/off selection switch - 1 st - 2 nd stage manual switch - Flame inspection window - Slide bars for easier installation and maintenance - Protection filter against radio interference - IP X0D (IP 40) electric protection level. Standard equipment - 1 gas train flange - 1 flange gasket - 4 screws for fixing the flange - 1 thermal screen - 4 screws for fixing the burner flange to the boiler - 3 plugs for electrical connection (RS 34-44 MZ single-phase) - 4 plugs for electrical connection (RS 44 MZ three-phase) - Instruction handbook for installation, use and maintenance - Spare parts catalogue. 440

Specification STATE OF SUPPLY RS 50-64 MZ - 70-100 - 130-150 - 190 models Monoblock forced draught gas burner with two stage operation, fully automatic, made up of: - Air suction circuit lined with sound-proofing material - Fan with reverse curve blades (RS 50-70 - 100-130 models) or straight blades (RS 64 MZ - 150-190 models) - Air damper for air flow setting and butterfly valve for regulating fuel output on 1 st and 2 nd stage controlled by a servomotor with variable cam - Starting motor at 2800 rpm, three-phase 400V with neutral, 50Hz - Combustion head, that can be set on the basis of required output, fitted with: - stainless steel end cone, resistant to corrosion and high temperatures - ignition electrodes - ionisation probe - gas distributor - flame stability disk - Minimum air pressure switch stops the burner in case of insufficient air quantity at the combustion head - Microprocessor-based burner safety control box, with diagnostic functions - Plug and socket for electrical connections (RS 50-64 models) - Burner on/off selection switch - 1 st - 2 nd stage manual switch - Flame inspection window - Slide bars for easier installation and maintenance - Protection filter against radio interference - IP 44 electric protection level. Standard equipment - 1 gas train flange - 1 flange gasket - 4 screws for fixing the flange - 1 thermal screen - 4 screws for fixing the burner flange to the boiler - Wiring loom fittings for the electrical connection (RS 50-64) - 2 slide bar extensions (for extended head models and RS 150-190 model) - Instruction handbook for installation, use and maintenance - Spare parts catalogue. GAS 441

Available models Burners CODE MODEL HEAT OUTPUT NATURAL GAS (kw) (Nm 3 /h) (kw) TOTAL ELECTRICAL POWER CERTIFICATION NOTE 3789010 RS 34 MZ TC FS1 1/230/50-60 230/50-60 44/130-390 4,5/13-39 0,6 CE 0085BR0381 (1) 3789011 RS 34 MZ TL FS1 1/230/50-60 230/50-60 44/130-390 4,5/13-39 0,6 CE 0085BR0381 (1) 20008266 RSP 34 TC FS1 1/230/50-60 230/50-60 44/130-390 4,5/13-39 0,6 CE 0085BR0381 (1) 3789110 RS 44 MZ TC FS1 1/230/50-60 230/50-60 80/200-550 8/20-55 0,7 CE 0085BR0381 (1) 3789111 RS 44 MZ TL FS1 1/230/50-60 230/50-60 80/200-550 8/20-55 0,7 CE 0085BR0381 (1) 3789140 RS 44 MZ TC FS1 3/230-400/50-60 230/50-60 80/200-550 8/20-55 0,8 CE 0085BR0381 (1) 3789141 RS 44 MZ TL FS1 3/230-400/50-60 230/50-60 80/200-550 8/20-55 0,8 CE 0085BR0381 (1) 3784702 RS 50 TC FS1 3/230-400/50 230/50-60 115/290-600 12/29-58 0,75 CE 0085AP0735 (1) 3784703 RS 50 TL FS1 3/230-400/50 230/50-60 115/290-600 12/29-58 0,75 CE 0085AP0735 (1) 3784720 RS 50 TC FS1 3/220-380/60 230/50-60 115/290-600 12/29-58 0,75 - (1) 3784721 RS 50 TL FS1 3/220-380/60 230/50-60 115/290-600 12/29-58 0,75 - (1) 3789310 RS 64 MZ TC FS1 3/230-400/50 230/50-60 150/400-850 15/40-85 1,5 CE 0085BR0558 (1) 3789311 RS 64 MZ TL FS1 3/230-400/50 230/50-60 150/400-850 15/40-85 1,5 CE 0085BR0558 (1) 3789380 RS 64 MZ TC FS1 3/220-380/60 230/50-60 150/400-850 15/40-85 1,5 - (1) 3789381 RS 64 MZ TL FS1 3/220-380/60 230/50-60 150/400-850 15/40-85 1,5 - (1) 3785102 RS 70 TC FS1 3/230-400/50 230/50-60 192/465-814 19/46,5-81 1,4 CE 0085AP0944 (2) 3785103 RS 70 TL FS1 3/230-400/50 230/50-60 192/465-814 19/46,5-81 1,4 CE 0085AP0944 (2) 3785104 RS 70 TC FS1 3/230-400/50 230/50-60 192/465-814 19/46,5-81 1,4 CE 0085AP0944 (1) (2) 3785105 RS 70 TL FS1 3/230-400/50 230/50-60 192/465-814 19/46,5-81 1,4 CE 0085AP0944 (1) (2) 3785120 RS 70 TC FS1 3/220-380/60 230/50-60 192/465-814 19/46,5-81 1,4 - (2) 3785121 RS 70 TL FS1 3/220-380/60 230/50-60 192/465-814 19/46,5-81 1,4 - (2) 3785302 RS 100 TC FS1 3/230-400/50 230/50-60 232/698-1163 23/70-116 1,8 CE 0085AP0945 (2) 3785303 RS 100 TL FS1 3/230-400/50 230/50-60 232/698-1163 23/70-116 1,8 CE 0085AP0945 (2) 3785304 RS 100 TC FS1 3/230-400/50 230/50-60 232/698-1163 23/70-116 1,8 CE 0085AP0945 (1) (2) 3785305 RS 100 TL FS1 3/230-400/50 230/50-60 232/698-1163 23/70-116 1,8 CE 0085AP0945 (1) (2) 3785320 RS 100 TC FS1 3/220-380/60 230/50-60 232/698-1163 23/70-116 1,8 - (2) 3785321 RS 100 TL FS1 3/220-380/60 230/50-60 232/698-1163 23/70-116 1,8 - (2) 3785502 RS 130 TC FS1 3/230-400/50 230/50-60 372/930-1512 37/93-151 2,6 CE 0085AP0946 (2) 3785503 RS 130 TL FS1 3/230-400/50 230/50-60 372/930-1512 37/93-151 2,6 CE 0085AP0946 (2) 3785504 RS 130 TC FS1 3/230-400/50 230/50-60 372/930-1512 37/93-151 2,6 CE 0085AP0946 (1) (2) 3785505 RS 130 TL FS1 3/230-400/50 230/50-60 372/930-1512 37/93-151 2,6 CE 0085AP0946 (1) (2) 3785520 RS 130 TC FS1 3/220-380/60 230/50-60 372/930-1512 37/93-151 2,6 - (2) 3785521 RS 130 TL FS1 3/220-380/60 230/50-60 372/930-1512 37/93-151 2,6 - (2) 20044636 RS 150 TC FS1 3/400/50 230/50-60 300/900 1850 30/90 185 3,5 in progress (2) 20044637 RS 150 TL FS1 3/400/50 230/50-60 300/900 1850 30/90 185 3,5 in progress (2) 20051309 RS 150 TC FS1 3/230/50 230/50-60 300/900 1850 30/90 185 3,5 in progress (2) 20051314 RS 150 TL FS1 3/230/50 230/50-60 300/900 1850 30/90 185 3,5 in progress (2) 3785813 RS 190 TC FS1 3/400/50 230/50-60 470/1279-2290 47/128-229 5,5 CE 0085AT0042 (2) 20030087 RS 190 TL FS1 3/400/50 230/50-60 470/1279-2290 47/128-229 5,5 CE 0085AT0042 (2) 20011698 RS 190 TC FS1 3/230/50 230/50-60 470/1279-2290 47/128-229 5,5 CE 0085AT0042 (2) 3785814 RS 190 TC FS1 3/400/50 230/50-60 470/1279-2290 47/128-229 5,5 CE 0085AT0042 (1) (2) 20011705 RS 190 TC FS1 3/230/50 230/50-60 470/1279-2290 47/128-229 5,5 CE 0085AT0042 (1) (2) 3785820 RS 190 TC FS1 3/380/60 230/50-60 470/1279-2290 47/128-229 5,5 - (2) 20011699 RS 190 TC FS1 3/220/60 220/60 470/1279-2290 47/128-229 5,5 - (2) Natural Gas, net calorific value: 10 kwh/nm 3 - Density at 20 C: 0,71 kg/nm 3 The burners of RS series are in according to 2009/142-2004/108-2006/95-2006/42 EC Directive and EN 676 Norm. (1) With plug and socket. (2) With terminal board. 442

Available models Gas Trains GAS TRAIN VPS ADAPTER CODE CODE MODEL Ø C.T. CODE RS 34 RS 44-50 RS 64 RS 70 RS 100 RS 130 RS 150 RS 190 3970500* MB 405/1 - RT 20 Rp ¾ - 3010123 l l l l l l 3970553* MB 407/1 - RT 20 Rp ¾ - 3010123 l l l l l l 3000824 3970599* MB 407/1 - RT 52 Rp ¾ - 3010123 l l l l l l 3970229* MB 407/1 - RSM 20 Rp ¾ - 3010123 l l l l l l 3970258* MB 410/1 - RT 52 Rp 1 ¼ - 3010123 3010124 3000843 l l l l 3970554* MB 410/1 - RT 20 Rp ¾ - 3010123 l l l l 3000824 + 3970600* MB 410/1 - RT 52 Rp ¾ - 3010123 3000824 l l l l 3000843 3970230* MB 410/1 - RSM 20 Rp ¾ - 3010123 l l l l 3970256* MB 412/1 - RT 52 Rp 1 ½ - 3010123 - - 3970144* MB 412/1 - RT 20 Rp 1 ½ - 3010123 - - 3970197** MB 412/1 CT RT 20 Rp 1 ½ u - - - 3970231* MB 412/1 - RSM 20 Rp 1 ½ - 3010123 - - 3970180* MB 415/1 - RT 30 Rp 1 ½ - 3010123 - - 3970198** MB 415/1 CT RT 30 Rp 1 ½ u - - - 3970250* MB 415/1 - RT 52 Rp 1 ½ - 3010123 - - 3970253** MB 415/1 CT RT 52 Rp 1 ½ u - - - 3970232* MB 415/1 - RSM 30 Rp 1 ½ - 3010123 - - 3970181* MB 420/1 - RT 30 Rp 2-3010123 3000843 - - - - - - 3970182** MB 420/1 CT RT 30 Rp 2 u - - - - - - - 3970257* MB 420/1 - RT 52 Rp 2-3010123 - - - - - - 3970252** MB 420/1 CT RT 52 Rp 2 u - - - - - - - 3000822 3970233* MB 420/1 - RSM 30 Rp 2-3010123 - - - - - - 3970234** MB 420/1 CT RSM 30 Rp 2 u - - - - - - - 3970221* MBC 1200/1 - RSM 60 Rp 2-3010367 - - - - - - 3970225** MBC 1200/1 CT RSM 60 Rp 2 u - - - - - - - 3970222* MBC 1900/1 - FSM 40 DN 65-3010367 l l 3970226** MBC 1900/1 CT FSM 40 DN 65 u - l l 3970223* MBC 3100/1 - FSM 40 DN 80-3010367 l l 3970227** MBC 3100/1 CT FSM 40 DN 80 u - l l 3000825 3000826 GAS Please see designation of Gas Train Series in the page before the Catalogue index. * 230V/50Hz -220V/60Hz electrical supply. ** 230V/50Hz electrical supply. The valve seal control device is compulsory (conforming to EN 676) on gas trains to burners with a maximum output over 1200 kw. To select the gas train please refer to the technical data leaflet and/or instruction manual. C.T. Gas valve leak detection control device: - gas train not equipped with leak detection control device; this device can be ordered separately - see VPS column - and installed later. u gas train equipped with leak detection control device. VPS Valve leak detection control device. Supplied separately from the gas train (please see Gas train accessories paragraph for both 50 Hz and 60 Hz codes). l Not available. 443

Available models Gas Trains GAS TRAIN VPS ADAPTER CODE CODE MODEL Ø C.T. CODE RS 34 RS 44-50 RS 64 RS 70 RS 100 RS 130 RS 150 RS 190 3970145* CB 512/1 - RSM 30 Rp 1 ½ - 3010367 - - 20045589** CB 512/1 CT RSM 30 Rp 1 ½ u - - - 3000843 3970146* CB 520/1 - RSM 30 Rp 2-3010367 - - - - - - 3970160** CB 520/1 CT RSM 30 Rp 2 u - - - - - - - 3000822 20044659* CB 525/1 - RSM 30 Rp 2-3010367 - - - - - - 20044660** CB 525/1 CT RSM 30 Rp 2 u - - - - - - - 3970147* CB 5065/1 - FSM 30 DN 65-3010367 l 3970161** CB 5065/1 CT FSM 30 DN 65 u - l 3000825 3970148* CB 5080/1 - FSM 30 DN 80-3010367 l l 3970162** CB 5080/1 CT FSM 30 DN 80 u - l l 3000826 3970149* CB 50100/1 - FSM 30 DN 100-3010367 l l 3970163** CB 50100/1 CT FSM 30 DN 100 u - l l 3010370 + 3000826 20015871* CB 50125/1 - FSM 30 DN 125-3010367 l l l l l 3970196** CB 50125/1 CT FSM 30 DN 125 u - l l l l l 3010224 + 3000826 Please see designation of Gas Train Series in the page before the Catalogue index. * 230V/50Hz -220V/60Hz electrical supply. ** 230V/50Hz electrical supply. The valve seal control device is compulsory (conforming to EN 676) on gas trains to burners with a maximum output over 1200 kw. To select the gas train please refer to the technical data leaflet and/or instruction manual. C.T. Gas valve leak detection control device: - gas train not equipped with leak detection control device; this device can be ordered separately - see VPS column - and installed later. u gas train equipped with leak detection control device. VPS Valve leak detection control device. Supplied separately from the gas train (please see Gas train accessories paragraph for both 50 Hz and 60 Hz codes). l Not available. 444

Burner accessories Extended head kit Standard head burners can be transformed into extended head versions, by using the special kit. The KITS available for the various burners, giving the original and the extended lengths, are listed below. Spacer kit STANDARD HEAD LENGTH (mm) EXTENDED HEAD LENGTH (mm) u RS 34 MZ 216 351 3010428 u RS 44 MZ 216 351 3010429 u RS 50 216 351 3010078 u RS 64 MZ 250 385 3010427 u RS 70 250 385 3010117 u RS 100 250 385 3010118 u RS 130 280 415 3010119 u RS 150 280 415 20052186 u RS 190 370 520 3010443 * * Kit to be used on burners recognizable by a serial number that is over or equal to 02426XXXXXX, for burners with a serial number that is under or equal to 02416XXXXXX please use the Kit coded 3010196 If burner head penetration into the combustion chamber needs reducing, varying thickness spacers are available, as given in the following table: SPACER THICKNESS S (mm) u RS 34 MZ - 44 MZ - 50 110 3010095 u RS 64 MZ - 70-100 - 130-150 135 3010129 u RS 190 102 3000722 GAS Continuous ventilation kit If the burner requires continuous ventilation in the stages without flame, a special kit is available as given in the following table: u RS 34 MZ - 44 MZ 3010449 u RS 50-64 - 70-100 - 130-150 - 190 3010094 Post-ventilation kit To prolong ventilation after opening of thermostats chain, a special kit is available. u All models POST-VENTILATION TIME (s) 5 3010004 20 3010452 445

Burner accessories Connection flange kit A kit is available for use where the burner opening on the boiler is of excessive diameter. u RS 34 MZ - 44 MZ - 50 3010138 Sound proofing box D E A If noise emission needs reducing even further, sound-proofing boxes are available. In case of generator heights, where a lower dimension B is required, ask for the Box Support Kit code 20065135. The useful dimensions are 40 mm less than the total dimensions indicated in the table (A, D, E). Not suitable for outdoor use. B BOX TYPE A (mm) B (mm) min-max C D E (mm) (mm) (mm) [db(a)] (*) BOX CODE C RS 34 MZ - 44 MZ u RS 50 - RS 64 MZ C1/3 650 372-980 110 690 770 10 3010403 u RS 70-100 - 130-150 - 190 C4/5 850 160-980 110 980 930 10 3010404 (*) Average noise reduction according to EN 15036-1 standard LPG kit For burning LPG gas, a special kit is available to be fitted to the combustion head on the burner, as given in the following table: FOR STANDARD HEAD FOR EXTENDED HEAD u RS 34 MZ 3010423 3010423 u RS 44 MZ 3010424 3010424 u RS 50 20008173 20008173 u RS 64 MZ 3010434 3010435 u RS 70 20008175 20008176 u RS 100 20008177 20008178 u RS 130 20008179 20008180 u RS 150 20050064 20050065 u RS 190 3010166 3010166 446

Two Stage Progressive Gas Burners Burner accessories Town gas kit For burning Town gas, a special kit is available: FOR STANDARD HEAD (*) FOR EXTENDED HEAD (*) u RS 34 MZ 3010502 3010502 u RS 44 MZ 3010503 3010503 u RS 50 3010285 3010285 u RS 70 3010286 3010286 u RS 100 3010287 3010287 u RS 130 3010288 3010288 u RS 190 3010297 3010297 (*) Without CE certification Vibration reduction kit The kit allow you to improve flame stability in some applications, where the boiler/flue assembly is liable to resonate. u RS 50 TC - RS 50 TL 3010200 u RS 70 TC - RS 70 TL 3010201 u RS 100 TC - RS 100 TL 3010202 u RS 130 TC 3010373 u RS 130 TL 3010374 u RS 190 TC 3010375 GAS Ground fault interrupter kit A Ground fault interrupter kit is available as a safety device for electrical system fault. u RS 34 MZ - 44 MZ 3010448 u RS 50 - RS 64 MZ 3010321 u RS 70-100 - 130-150 - 190 3010329 Gas max pressure switch kit If necessary a Gas max pressure Switch kit is available. u RS 34 MZ - 44 MZ* 3010418 u RS 50-64 MZ - 70-100 - 130-150 - 190 3010493 * Connectable to the burner electrical wiring through Plugs & Sockets system 447

Burner accessories Volt free contact kit A volt free contact kit is available for installation onto the burner. It can be used for a remote interface between burner operating signals. Every burner can be equipped with a single kit for a remote check of the flame presence signal and the burner lockout indication. u RS 34 MZ - 44 MZ - 64 MZ 3010419 PC interface kit To connect the control box to a personal computer for the transmission of operation, fault signals and detailed service information, an interface adapter with PC software are available. u RS 34 MZ - 44 MZ - 50-64 MZ - 70-100 - 130-150 - 190 3002719 Hours counter kit To measure the burner working time a hours counter kit is available. u RS 34 MZ - 44 MZ 3010450 DN80 gas flange kit To modify the standard 2 burner gas input connection in to DN80 connection, a specific gas flange is available. u RS 64 MZ - 70-100 - 130-150 - 190 3010439 448

Burner accessories Protection kit (electromagnetic interferences) When the burner is installed in a room particularly subject to electromagnetic interference (signals emitted over 10 V/m) due for example to INVERTER presence or in systems where the lengths of the thermostat connections is over 20 meters, this specific protection kit is available as an interface between the thermostatic controls and the burner. u All models 3010386 Head kit for reverse flame chamber In certain cases, the use of the burner on reverse flame boilers can be improved by using an additional cylinder. STANDARD HEAD LENGTH WITH CYLINDER (mm) EXTENDED HEAD LENGTH WITH CYLINDER (mm) (*) u RS 190 493-3010241 (*) EC certification in progress Gas train accessories GAS Adapters In certain cases, an adapter must be fitted between the gas train and the burner, when the diameter of the gas train is different from the set diameter of the burner. Below are given the available adapters; please see on the Gas Train list the correct adapter codes to select. ADAPTER LENGTH mm ADAPTER CODE 2 1 1/2 70 3000822 3/4 1 1/2 31 3000824 2 1/2 2 DN 65 300 3000825 2 1/2 1 1/2 DN 80 2 1/2 2 300 3000826 1 1/2 2 35 3000843 1 1/4 1 1/2 35 3010124 1 1/4 2 35 3010126 449

Gas train accessories Stabiliser spring Accessory springs are available to vary the pressure range of the gas train stabilisers. The following table shows these accessories with their application range. Please refer to the technical manual for the correct choice of spring. u GAS TRAIN MBC 1900/1-3100/1 MBC 5000/1 u CB 512/1 u CB 520/1-525/1 u CB 5065/1-5080/1 SPRING COLOUR SPRING PRESSURE RANGE mbar SPRING CODE White 4-20 3010381 Red 20-40 3010382 Black 40-80 3010383 Green 80-150 3010384 Red 25-55 3010131 Black 60-110 3010157 Pink 90-150 3090486 Red 25-55 3010132 Black 60-110 3010158 Pink 100-150 3090487 Red 25-55 3010133 Black 60-110 3010135 Pink 100-150 3090456 Grey 140-200 3090992 Seal control kit To test the valve seals on the gas train, a special seal control kit is available. The valve seal control device is compulsory (EN 676) on gas trains to burners with a maximum output over 1200 kw. The seal control is type VPS 504. GAS TRAIN for 50 Hz operation for 60 Hz operation u MB/1 type 3010123 20050030 u MBC/1 type 3010367 20029057 u CB/1 type 3010367 20029057 450