Series CK Three and four pole contactors 150 to 825 (C3) 200 to 1250 (C1) Control circuit: lternating current up to 690V Direct current up to 500V Degree of protection IP00 (IPxx with accessories) CK07...CK13: auxiliary and coil terminals originally protected against accidental contacts Protection for power contacts on request (see accessories) Terminals protected against accidental contacts according to VDE 0106 T.100, VG4 CK E_with electronic module suitable for DC and C. (50/60Hz) CK contactors always provided with one auxiliary contact block CLL11 (1NO+1NC) Contactors Standards Standard voltages C IEC/EN 60947-1 IEC/EN 60947-4-1 IEC/EN 60947-5-1 EN 50005 UL 508 NEM ICS 1 S 5424 & 775 CS 22.2/14 CENELEC HD 419 NFC 63-110 SE 1025 UNE 20109 VDE 0660/102 To complete the catalogue number, replace the symbol by the code corresponding to the voltage and frequency of the control circuit. (other voltages on request)* lternating current (V) Three-pole contactors: CK75C3..., CK08C3..., CK853... Four-pole contactors: CK074..., CK084... C D F G H I J K M N R S T U V W X Y Z D pprovals 50Hz 24 42 48 110 127 220 240 380 415 440 500 660 230 400 690 60Hz 24 48 110 120 220 277 240 380 480 440 600 E culus (1) CE lternating current (V). Dual-frequency coil Three-pole contactors: CK75C3..., CK08C3..., CK853... Four-pole contactors: CK074..., CK084... 1 2 3 6 13 F 50/60Hz 24 48 110 230 400 G H Lloyd s Register ureau Veritas RIN lternating current (V) Three-pole contactors: CK133... Four-pole contactors: CK134... J N U Y Z 50/60Hz 110 220 380 480 600 240 440 500 660 Control circuit with rectifier bridge J N U 50Hz 110 220 380 230 400 60Hz 120 240 480 I X Order codes uxiliary contact blocks ccessories & Spares Dimensions pg. C.19 pg. C.20 pg. C.21 pg. C.30 Direct current (V). With electronic module (0.7... 1.3 x Us) Three-pole contactors: CK75CE3..., CK08CE3... WD WE WF WH WJ WN Voltage 24 33 48 72 110 220 lternating c. / Direct c. (V). With electronic module (0.8... 1.10 x Us) Three-pole & four-pole contactors: CK... E... D F J N U Y Voltage 24 42 110 220 380 440 28 48 127 250 415 500 (1) CK13 not UL C.18 * Please Consult GE for non standard Coil Voltages
Series CK Three pole contactors Max.oper.current Noninductive loads C1 Motors <440V, 3 ~ 50/60Hz C3 250 150 dmissible power C3 220V 380V 415V 440V 500V 230V 400V 440V kw kw kw kw kw HP HP HP HP HP Electrical endurance Cat. C3 Operations 45 75 80 80 100 1.7x10 6 60 100 108 108 135 Control circuit: lternating current Cat. no. (1) Pack Ref. no. see bottom CK75C311 1 Control circuit:.c. / D.C. Cat. no. (1) Pack Ref. no. see bottom CK75CE311 1 250 185 315 205 315 250 450 309 600 420 700 550 55 90 100 100 110 1.2x10 6 75 125 135 135 150 65 110 125 125 132 1.7x10 6 88 150 170 170 180 75 132 132 132 160 1.5x10 6 100 180 180 180 220 90 160 160 185 200 1,1x10 6 125 220 220 250 270 125 220 230 230 300 1x10 6 170 300 312 312 405 160 280 315 315 400 0.8x10 6 220 380 425 425 540 CK08C311 1 CK85311 1 CK08CE311 1 CK85E311 1 CK09E311 1 CK95E311 1 CK10CE311 1 CK11CE311 1 3P and 4P contactors 1000 700 1250 825 220 375 400 425 480 0.7x10 6 300 510 540 650 250 450 450 450 500 0.7x10 6 340 610 610 610 680 (2) CK13311 1 CK12E311 1 Spare coil CK75C3... CK08C3 CK853 CK133 Control circuit with incorporated rectifier bridge CK133 Coil Electronic module CK75CE3... CK08CE3 CK85E3... CK95E3 CK12E3 CK10CE3... CK11CE3 CK75CE3... CK08CE3 CK85E3... CK95E3 CK12E3 CK10CE3... CK11CE3 C12168 1 C04255 1 C08998 1 C09120 1 K4E 1 K5E 1 K6E 1 K7E 1 KM4E 1 KM5E 1 KM6E 1 KM7E 1 (1) To complete the catalogue number, replace the symbol by the code corresponding to the voltage and frequency of the control circuit (see C.18). (2) CK13 non alow the aux. block in right side. C D E F G H I X C.19
C Contactors ux. Contacts Full Voltage Non-Reversing CK75CE311* CK08CE311* Reversing KR75C* KR08C* Maximum ux. Contacts 8 8 Maximum Contact lock Configuration 2 Side-Mount on each side ux. Contacts (600, Q600) 1NO-1NC 1NO-1NC Continuous mp Rating (UL) 150 175 C-1 mperes (IEC) 200 250 C-2/C-3 Max. FL 140 156 Max. Hp (1-Phase) 115 Volts 10 15 230 Volts 25 30 Max. Hp (3-Phase) 200 Volts 40 50 230 Volts 50 60 460 Volts 100 125 575 Volts 125 125 200 Volts 40 50 C-4 Max. Hp 230 Volts 50 60 460 Volts 100 125 575 Volts 125 125 Mechanical Life (millions of operations) 10 10 Elec. Endurance (C-3) t Rated Current 1.8 1.5 (millions of operations) C-1 600 ops./hour 150 175 1200 ops./hour 125 140 Maximum Operational 3000 ops./hour 50 70 Current C-3 600 ops./hour 140 156 460V and 1200 ops./hour 100 115 elow 3000 ops./hour 30 39 Net Weight 3-Pole Contactors 100-125 HP (460V) 140-156 FL Contactor catalog numbers are shown in the shaded area in the Contactor Selection and Data table. To complete the catalog number, replace the asterisk (*) with the appropriate digit from the shaded area in the Coil Selection table. dditional coil information is shown in the Coil Data table. Contactor Selection and Data Hp @ 460V C-3 (kw @ 380/415V, 50 Hz) 100 hp (75 kw) 125 hp (90 kw) C-4 200 ops./hour max 140 156 Contactor 8 lb. 5 oz. 8 lb. 5 oz. Class 10 Overload Relay 1 lb. 15 oz. 1 lb. 15 oz. Wire Size - Power Terminals 75 C (Cu) WG #6-250 MCM #6-250 MCM Torque (Main) in.-lb. 275 275 (applicable to lug kit CKX03) Noise (dba) 45 45 Terminal Hole Dia..320.320 Screw Size M-8 M-8 Coil Selection C (50/60 Hz) Coil * DC Suffix 24-28 D 42-48 F 110-127 J 220-250 N 380-415 U 440-500 Y C Voltage urden Inrush 350 V Holding 20 V Pick-up Voltage (% Of Coil Volts) 80-110 Coil Data Drop-Out Voltage (% Of Coil Volts) 40-60 Switching Delay (ms) Switching Delay On Coil Voltage t Rated Value 60-70 Switching Delay Off Coil Voltage t Rated Value 13-17 Maximum Operations per Hour No Load 1200 Rated Load C1, C3 600 Rated Load C4 150 REFERENCES Standards and Listings...Page 41 Overload Relays...Pages 26-29 ccessories...pages 30-37 Life Curves...Pages 42-44 dditional Coil Information...Page 37 Instruction Sheet...GEH-6530 UL File Number...E76233 CS File Number...LR30821 14
C-2000 Contactors & Starters 3-Pole Contactors 100-125 HP (460V) 140-156 FL Legend and Notes for Illustration Extra uxiliary Contacts, Side Mounted (if used) (1 Standard) Electronic ctuator Modulator Engineering Outline Drawings C/DC Contactor...55-216415 Starter...55-216412 Reversing Contactor...55-216410 Reversing Starter...55-216411 Contactor - Front View Starter - Front View Reversing Contactor - Front View Reversing Starter - Front View C Contactor - Side View C Starter - Side View 15
Standards nd Listings IEC 947-1 S 5424 CS C.22.2/14 IEC 947-4 S 775 EN 50005 IEC 158-1 CEI 17-3/252 UNE 20109 GENELEC HD419 SE 1025 VDE 0660/102 NFC.63-110 UL 508 CE Mark C-2000 Contactors & Starters General Specifications Pending Standards nd Listings mbient Temperature Operating Storage SEMKO, NEMKO, DEMKO, Lloyds Register -13 to +131 F/-25 to +55 C -58 to +176 F/-50 to +80 C ltitude Derating Up to 10,000 ft. Nominal Values (3,000 m) 10,000 to 13,200 ft. 90% rated current (3,000 to 4,000 m) 13,200 to 16,000 ft. 80% rated current (4,000 to 5,000 m) Rated Insulation Voltage 600 VC, U I = 1000V (IEC 947-1) Mounting Position 3-Pole and 4-Pole CL Contactors (5-75 hp) To maintain operating integrity, the contactor must be mounted in one of the positions shown below: 3-Pole and 4-Pole CK Contactors (100-500 hp) The contactor must be installed vertically or tilted a maximum of 30 from vertical, as shown below: 41