Elle Surface Mounting Instructions

Similar documents
Elle Surface Mounting Instructions

HP-2 / HP-6 Direct Installation Instructions Overview

HBDBM High Bay Series

INSTALLATION INSTRUCTIONS

High Bay Luminaire Series

General Installation Instructions LED

SURFACE/CEILING & SUSPENDED MOUNT INSTALLATION

INSTALLATION INSTRUCTIONS LIGHTPLANE 3.5. LP3.5 Suspended LED. A nd Avenue, Unit 1. CA P E W alwusa.

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION

Lighting Systems Argus-7

MEDIA LED. Pendant Standard Mount Installation ou de montage WARNING:

LED Recessed Troffer Retrofit Kit

M36 LED Recessed Quickship

EMERY SKY SUSPENDED LED LUMINAIRE

Luminaire Support Location Cable Mounting Kit. Non-Power Feed

INSTALLATION INSTRUCTIONS

Customer service: or Upper mounting ring. Canopy

Installation Instructions: Eco Linear High Bay

AEROBAY INSTALLATION INSTRUCTIONS

LED Flat Panel Installation Instructions For 1 x4, 2 x2, and 2 x4 LED Flat Panels (FP Series)

The installation must only be performed by a licensed electrician. Disconnect power before installing the product or servicing it.

LIGHTPLANE 1 RECESSED - LP1R

Installation Instructions MX LED Enhanced Color Adjustable

Albeo TM LED Luminaire Heavy Industrial High Bay Lighting (ABR1-Series)

HIGHBAY RAIL 400W INSTALLATION INSTRUCTIONS

Lumination TM LED Luminaires LAL Series - Continuous Run Option

WARNING NORDIC ALUMINIUM LIGHTING TRACK SYSTEMS

Circa Ambient Interior Luminaire

INSTALLATION INSTRUCTIONS MOONRING 1 LP1/MR1

INSTRUCTIONS FOR INSTALLING MIND/MOTION SENSOR/E-PORT ON USI ALPINE FOOD MACHINE

RECESSED WALL WASH MOUNT

Two Circuit Trac System TRAC SECTION, JOINERS & FEEDS

COMPACT BUSWAY 40 & 60 AMP HOUSING

OPTIMAX RADIANT FIELD RETROFIT INSTRUCTIONS

When using electrical equipment, basic safety precautions should always be followed including the following:

Input Voltage: AC: VAC HC: VAC (50/60Hz) Electrical Ratings: WIDE FROSTED MODEL

INSTALLATION INSTRUCTION W Track Recessed 120V Flangeless

Instruction page index: Installation Instructions for Kendo L & Kendo XL Models KL-XX & KXL-XX. Page 1 of 6

Round or Square Chicago Plenum Hi-lume Wall Wash Housing with LED Lamp for Flanged Trims E3_F_-L_WC-HL 1.0

NT-300 Series Single Circuit Track System & Accessories

LED IMPORTANT SAFETY INSTRUCTIONS

Installation Instructions 4 Gravity Enhanced Color Adjustable

INSTALLATION INSTRUCTION W Track Suspension system

ILLUMINA BS100 INSTALLATION INSTRUCTIONS FLUORESCENT VAPOR TIGHT

1Unpack fixture. Suspensions/canopies are ordered and

INSTALLATION INSTRUCTIONS 120V DirectAC LED Engine Kit

RECESSED ASYMMETRIC MOUNT

UV8 & UV90 SERIES INSTALLATION INSTRUCTIONS

HLS House Lighting System SURFACE MOUNT, 4-CIRCUIT REMOTE POWER SUPPLY

INSTALLATION INSTRUCTIONS SUPERPLANE 2.5. Suspended. A nd Avenue, Unit 1 Oakland, CA P E W alwusa.

Chatham - Pendant DESCRIPTION FEATURES & BENEFITS SPECIFICATIONS PROJECT DETAILS AIP8180. Job Name: Type: Notes:

Assembly instruction. Pendant Light Toccata GENERAL REMARKS ON SAFETY: Technical data: BOM

MOONRING 1.5 MOONRING 3

Installation Instruction

Two Circuit Trac System TRAC SECTION, JOINERS & FEEDS

HP-4 Recessed with Regressed Visible Flange Starter/Independent Installation Instructions

LED Utility Wrap Fixture

Lumination TM LED Luminaire LUR Series

HLS Cross-Aisle, Stairs & Landing SURFACE MOUNT, 2-CIRCUIT REMOTE POWER SUPPLY

Installation Instructions Sero / Qub Pendant RETROFIT CONSTRUCTION- INACCESSIBLE CEILING Mounting Option GP

Product Overview. High Power 7W/ft. Fixture Summary (see following pages for more information) Power Level Watts Per Foot

Apollo 8. lamping. patient bed pair example. 8" wide recessed patient bed light with exam function available in 2', 3' & 4' lengths.

HLS Cross-Aisle Pivot AIMABLE SURFACE MOUNT SAFETY LIGHTING REMOTE POWER SUPPLY

ULTRA PERFORMANCE LED TUBE INSTALLATION INSTRUCTIONS

Ivalo Finiré 3 LED Recessed Lighting Installation Instructions

Qty: L6JR2 Continuous Flange (Flangeless Endcaps) 1B25 1,2 430lm/6.3W per foot. 1B30 1,2 480lm/7.2W per foot. 1B lm/8.5w per foot K

Installation Instructions: Eco SpunBay LED High Bays

INSTALLATION INSTRUCTION Aether 2 Shallow Recessed Housing

Installation Instructions

One Circuit Trac System TRAC SECTION, JOINERS & FEEDS T Series

INSTALLATION INSTRUCTION MANUAL

HPNLS-HO. Installation Manual

Notes: Indirect. 5 1/2" 140mm. 5 1/32 128mm

Round or Square Type Non-IC Adjustable Housing with Toroidal Transformer for Flangeless Trims E3_L_-HANM_ 1.7

INSTALLATION GUIDE INSTALLATION GUIDE

TRAC-LITES One Circuit Trac System TRAC SECTIONS & SYSTEM COMPONENTS R Series

CFP-LED Contractor Select Flat Panel. Installation Instructions

HP90 Recessed 2'X2' Fluorescent; T8, T5, T5HO or TT5

INSTALLATION INSTRUCTION Aether 3.5 Color Tunable LED Downlight

LED UFO High Bay with j-box Installation Instruction

MIDTOWN INSTRUCTIONS. White, Silver, Black. Single Light. MIDTOWN LED Recessed Light Installation Guide LED RECESSED LIGHT. (The nuts & bolts)

Madrid - Pendant DESCRIPTION FEATURES & BENEFITS SPECIFICATIONS PROJECT DETAILS AIP8508. Job Name: Type: Notes:

INSTALLATION GUIDE INSTALLATION GUIDE

RECESSED TRACK (120V) SPECIFICATIONS

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE INSTALLATION INSTRUCTIONS SECURITY HID CAUTIONS: DIRECT MOUNTING TO RECESSED BOX (WALL OR CEILING)

Mirror Solutions Bevel & Pivot Models Installation Instructions INSTALLATION INSTRUCTIONS. Figure 1

avenue led features dimensional data performance Narrow 3" slot LED with frosted satin lens.

PERIMETER - RECESSED. Regressed 3" BMPRLED OPRI ( 1) 14 PRODUCT ID LINEAR OR CORNER QTY TOTAL LENGTH. 3D VIEW - Inside Corner Pattern

PERIMETER - RECESSED. Flush BBPRLED OPRI ( 1) 14 PRODUCT ID LINEAR OR CORNER QTY TOTAL LENGTH. 3D VIEW - Inside Corner Pattern

NOVA suspension up and down, end feed with remote power supply

Ciros P-ID-5200 Pendant-Mounted Indirect/Direct

Options AMF Antimicrobial Finish (All Exposed Surfaces) BLK Black Doorframe. Accessory

Notes: 3 1/2" 89mm. 1/2" 13mm

HBDB High Bay Fixture with Occupancy Sensor

One Circuit Trac System TRAC SECTION, JOINERS & FEEDS T Series

Notes: (1) not recommended with staggered lamping (2) Not available with T8 lamping.

ZIP LIGHT LED LUMINAIRE

GEMINI HOUSING SPECIFICATIONS

ASSEMBLY AND INSTALLATION INSTRUCTIONS

C3R RIGID LED LINEAR ACCENT LIGHTING, LOW-POWER

Transcription:

Step 1: Preparation, page 2 Warnings CAUTION risk of fire and this product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved. Electrical service must be disconnected during installation. Proper grounding is required to protect against shock and proper operation. Step 2: Starter luminaire, page 3 Step 3: Adding luminaires, page 4 Troubleshooting and getting to the driver and LEDs, page 5 Notes: Do not install luminaires on the ground and use proper support when hanging. All power connections to be installed to appropriate codes by a certified electrician. This in an example run only. Your installation may vary from this example. Stuctura, Inc. 19922 W. 162nd St., Olathe, KS 66062 913.390.8787 www.structura.com Page 1

Step 1: Preparation Note: Refer to factory run drawings for exact mounting, suspension, and power feed locations. Section A: Starter Luminaire Section B: Section C: Section D: Organize and identify luminaires required for run using the record drawing for the project created by the factory. Layout boxes by fixture type and section letter as indicated on the box label as shown below. Project Name XYZ COMPANY ELLE-8-U1L-STG-D-30-80-S0-W3-05-UNV Type: G1-1 Section: A Full Catalog Number Run Section Fixture Schedule Type Stuctura, Inc. 19922 W. 162nd St., Olathe, KS 66062 913.390.8787 www.structura.com Page 2

Step 2: Starter Luminaire Mounting Mount starter to structure Terminate electrical connections T-Grid Clips Flex Conduit (by others) 1. Release ceiling mounting bracket by removing 1/4-20 spanner screws using supplied spanner bit. 2. Attach mounting bracket to ceiling using supplied T-grip clips or hardware appropriate to building code through center slots. 3. Run flex conduit (by others) to starter luminaire location and connect to wire leads. 4. Place luminaire back onto mounting bracket. Align spanner screw holes with connector leg of mounting bracket. 5. Resecure with spanner screw. Black White Green Grey Purple Red* Conductor Leads Hot Neutral Ground Dimming Dimming *Used for controls and emergency options. Line Voltage Line Voltage 0-10V 0-10V Stuctura, Inc. 19922 W. 162nd St., Olathe, KS 66062 913.390.8787 www.structura.com Page 3

Step 3: Creating Luminaire Runs WARNING: DO NOT JOIN LUMINAIRES TOGETHER ON THE FLOOR. DAMAGE MAY OCCUR WHEN LIFTING. End-to-End Connection Leg-to-Top Connection Quick Connect Connector Legs Quick Connect 360 1. Mount connecting luminaire s mounting bracket to ceiling with end butted up against starter luminaire. 2. Hold connecting luminaire to mounting bracket with gap between luminaires. 3. Connect male and female ends of quick connect. 4. Slide luminaire towards starter luminaire and secure in place with supplied 1/4-20 spanner screw. 1. Connect male and female ends of quick connect. 2. Hold end of second luminaire up to leg of uppercase luminaire aligning to groove in top of luminaire. 3. Secure second luminaire with 1/4-20 spanner screw using supplied spanner bit. Note: Do not rotate past 360 as wires will twist. Stuctura, Inc. 19922 W. 162nd St., Olathe, KS 66062 913.390.8787 www.structura.com Page 4

Troubleshooting Accessing LED and Driver 1 2 Geartray Screw 3 1. Remove acrylic lens by pushing lens upward at an angle until side comes out. 2. Remove four Philips screws (two at each end of tray) indicated in drawing above to loosen LED geartray. 3. LED driver is located on the back of the geartray. Note: Do not pin wire between geartray and inner housing when reinstalling geartray. Stuctura, Inc. 19922 W. 162nd St., Olathe, KS 66062 913.390.8787 www.structura.com Page 5