Elle Surface Mounting Instructions

Similar documents
Elle Surface Mounting Instructions

HP-2 / HP-6 Direct Installation Instructions Overview

HBDBM High Bay Series

INSTALLATION INSTRUCTIONS LIGHTPLANE 3.5. LP3.5 Suspended LED. A nd Avenue, Unit 1. CA P E W alwusa.

INSTALLATION INSTRUCTIONS

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION

Customer service: or Upper mounting ring. Canopy

SURFACE/CEILING & SUSPENDED MOUNT INSTALLATION

High Bay Luminaire Series

The installation must only be performed by a licensed electrician. Disconnect power before installing the product or servicing it.

EMERY SKY SUSPENDED LED LUMINAIRE

ILLUMINA BS100 INSTALLATION INSTRUCTIONS FLUORESCENT VAPOR TIGHT

Circa Ambient Interior Luminaire

INSTALLATION INSTRUCTIONS MOONRING 1 LP1/MR1

AEROBAY INSTALLATION INSTRUCTIONS

MOONRING 1.5 MOONRING 3

Installation Instructions: Eco Linear High Bay

General Installation Instructions LED

INSTALLATION INSTRUCTIONS 120V DirectAC LED Engine Kit

Lumination TM LED Luminaires LAL Series - Continuous Run Option

UV8 & UV90 SERIES INSTALLATION INSTRUCTIONS

M36 LED Recessed Quickship

Lighting Systems Argus-7

NOTE: The orientation of the mounting brackets are critical. (See Figure 4)

ULTRA PERFORMANCE LED TUBE INSTALLATION INSTRUCTIONS

LED Recessed Troffer Retrofit Kit

INSTRUCTIONS FOR INSTALLING MIND/MOTION SENSOR/E-PORT ON USI ALPINE FOOD MACHINE

INSTALLATION INSTRUCTION MANUAL

LED IMPORTANT SAFETY INSTRUCTIONS

Albeo TM LED Luminaire Heavy Industrial High Bay Lighting (ABR1-Series)

INSTALLATION GUIDE INSTALLATION GUIDE

Round or Square Chicago Plenum Hi-lume Wall Wash Housing with LED Lamp for Flanged Trims E3_F_-L_WC-HL 1.0

INSTALLATION INSTRUCTIONS SUPERPLANE 2.5. Suspended. A nd Avenue, Unit 1 Oakland, CA P E W alwusa.

SloanLED THINLED. Constant Current. Installation Guide

Silvus TM 30 Exterior

Chatham - Pendant DESCRIPTION FEATURES & BENEFITS SPECIFICATIONS PROJECT DETAILS AIP8180. Job Name: Type: Notes:

INSTALLATION INSTRUCTIONS

HIGHBAY RAIL 400W INSTALLATION INSTRUCTIONS

Installation Instructions Sero / Qub Pendant RETROFIT CONSTRUCTION- INACCESSIBLE CEILING Mounting Option GP

Installation Instructions MX LED Enhanced Color Adjustable

INSTALLATION GUIDE INSTALLATION GUIDE

Input Voltage: AC: VAC HC: VAC (50/60Hz) Electrical Ratings: WIDE FROSTED MODEL

OPTIMAX RADIANT FIELD RETROFIT INSTRUCTIONS

Ivalo Finiré 3 LED Recessed Lighting Installation Instructions

Two Circuit Trac System TRAC SECTION, JOINERS & FEEDS

LED Utility Wrap Fixture

Installation Instructions: Eco SpunBay LED High Bays

Instruction page index: Installation Instructions for Kendo L & Kendo XL Models KL-XX & KXL-XX. Page 1 of 6

MEDIA LED. Pendant Standard Mount Installation ou de montage WARNING:

Installation Instructions: External-Driver SEP T8 LED Tube Lamp

LED Garage Light INSTALLATION INSTRUCTIONS. *Model number noted on carton label

Installation Instructions: Memory-Dimmable SEP T8 Tube Lamps

Round or Square Type Non-IC Adjustable Housing with Toroidal Transformer for Flangeless Trims E3_L_-HANM_ 1.7

Madrid - Pendant DESCRIPTION FEATURES & BENEFITS SPECIFICATIONS PROJECT DETAILS AIP8508. Job Name: Type: Notes:

Installation Instruction

MODEL 2604 WARNING <THESE INSTRUCTIONS MUST BE GIVEN TO THE END USER> Custom 5th Wheel Hitch Mounting Rail Installation Instructions

HAZARDOUS LOCATION STREET LIGHT SLA SERIES INSTALLATION INSTRUCTIONS

HP-4 Recessed with Regressed Visible Flange Starter/Independent Installation Instructions

Two Circuit Trac System TRAC SECTION, JOINERS & FEEDS

Notes: Indirect. 5 1/2" 140mm. 5 1/32 128mm

RECESSED WALL WASH MOUNT

MIDTOWN INSTRUCTIONS. White, Silver, Black. Single Light. MIDTOWN LED Recessed Light Installation Guide LED RECESSED LIGHT. (The nuts & bolts)

Qty: 1B40 1,2 958lm/10.4W per foot 1B B lm/6.8W. per foot. 2B lm/15.4W per foot. 2B lm/10.2W per foot. 2B lm/18.

INSTALLATION INSTRUCTION Aether 2 Shallow Recessed Housing

HBDB High Bay Fixture with Occupancy Sensor

Mirror Solutions Bevel & Pivot Models Installation Instructions INSTALLATION INSTRUCTIONS. Figure 1

Notes: (1) not recommended with staggered lamping (2) Not available with T8 lamping.

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE INSTALLATION INSTRUCTIONS SECURITY HID CAUTIONS: DIRECT MOUNTING TO RECESSED BOX (WALL OR CEILING)

Assembly instruction. Pendant Light Toccata GENERAL REMARKS ON SAFETY: Technical data: BOM

Installation Instructions: ACCENT SYSTEM

RECESSED ASYMMETRIC MOUNT

GENUINE PARTS INSTALLATION INSTRUCTIONS

Motion and Light Sensor Kit LHBAS51

INSTALLATION INSTRUCTION W Track Suspension system

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

LED 2/3/4ft T8 Tube 120V

COOLEDGE TILE EXTERIOR INSTALLATION INSTRUCTIONS FIT-2. Caution: Observe precautions for handling electrostatic sensitive devices.

When using electrical equipment, basic safety precautions should always be followed including the following:

Installing and Setting Up Your Ring Floodlight Cam

Qty: L6JR2 Continuous Flange (Flangeless Endcaps) 1B25 1,2 430lm/6.3W per foot. 1B30 1,2 480lm/7.2W per foot. 1B lm/8.5w per foot K

LED UFO High Bay with j-box Installation Instruction

LED Adjustable Cutoff Wallpack

INSTALLATION INSTRUCTION Aether 3.5 Color Tunable LED Downlight

Operation/Installation Instructions

LUFOHB IP65. Premium Round LED High Bay, 14,000 32,000 Lumens ( W) WARRANTY & LISTINGS FEATURES MOUNTING OPTIONS DIMENSIONS

A-L810 Steady-Burning Red LED Obstruction Light Installation and Maintenance Manual

Bionic Perimeter Standard C o v e & P e r i m e t e r

JEEVES. JEEVES Installation Manual. Installation Manual The Easiest Do-It-Yourself Dumbwaiter on the Market

INSTALLATION INSTRUCTION MANUAL

Installation and Operation Instructions 10/04/13

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V)

C.fm Page 1 Thursday, February 21, :28 AM Raptor user manual

Electrobar Elite. Instruction Manual. Conductor Bar System. ELITE-03A October 2011 Part Number: R3 Copyright 2011 Electromotive Systems

HPNLS-HO. Installation Manual

One Circuit Trac System TRAC SECTION, JOINERS & FEEDS T Series

PIPING. Aluminium pipe for inert gases (5,7 m / 18,7 ft) PAGE 2/ AIRNET Ø (MM / INCH) PARTNUMBER LOT SIZE / ¾" 05

Mizer Single Pump and Starter Box

Product Overview. High Power 7W/ft. Fixture Summary (see following pages for more information) Power Level Watts Per Foot

I. Pendant Mount Installation

INSTALLATION INSTRUCTIONS

Transcription:

Step 1: Preparation, page 2 Warnings CAUTION risk of fire and this product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved. Electrical service must be disconnected during installation. Proper grounding is required to protect against shock and proper operation. Step 2: Starter luminaire, page 3 Step 3: Adding luminaires, page 4 Troubleshooting and getting to the driver and LEDs, page 5 Notes: Do not install luminaires on the ground and use proper support when hanging. All power connections to be installed to appropriate codes by a certified electrician. This in an example run only. Your installation may vary from this example. Stuctura, Inc. 19922 W. 162nd St., Olathe, KS 66062 913.390.8787 www.structura.com Page 1

Step 1: Preparation Note: Refer to factory run drawings for exact mounting, suspension, and power feed locations. Section A: Starter Luminaire Section B: Section C: Section D: Organize and identify luminaires required for run using the record drawing for the project created by the factory. Layout boxes by fixture type and section letter as indicated on the box label as shown below. Project Name XYZ COMPANY ELLE-4-L2E-WAL-DIS-35-80-H0-W1-05-UNV Type: G1-1 Section: A Full Catalog Number Run Section Fixture Schedule Type Stuctura, Inc. 19922 W. 162nd St., Olathe, KS 66062 913.390.8787 www.structura.com Page 2

Step 2: Starter Luminaire Mounting Mount starter to structure Luminaire Mounting Screw Wall Mounting Bracket Terminate electrical connections 3. Run flex conduit (by others) through wire hole and connect to luminaire wire leads. 4. Place luminaire back onto mounting bracket aligning 1/4-20 screws with thread insert in mounting bracket. 5. Tighten screws to secure luminaire to mounting bracket. Black White Green Grey Purple Red* Conductor Leads Hot Neutral Ground Dimming Dimming *Used for controls and emergency options. Line Voltage Line Voltage 0-10V 0-10V Wire Hole Junction Box Cover Thread Insert Junction Box (by others) 1. Release wall mounting bracket by removing 1/4-20 socket cap screws from assembly. 2. Attach mounting bracket to wall using hardware appropriate to building code locating wire hole in front of junction box (junction box supplied by others). Stuctura, Inc. 19922 W. 162nd St., Olathe, KS 66062 913.390.8787 www.structura.com Page 3

Step 3: Creating Luminaire Runs WARNING: DO NOT JOIN LUMINAIRES TOGETHER ON THE FLOOR. DAMAGE MAY OCCUR WHEN LIFTING. End-to-End Connection Leg-to-Top Connection Mounting Screw Quick Connect Connector Legs Quick Connect Mounting Screw 360 1. Mount connecting luminaire s mounting bracket to wall with end butted up against starter luminaire. 2. Hold connecting luminaire to mounting bracket with gap between luminaires. 3. Connect male and female ends of quick connect. 4. Slide luminaire towards starter luminaire and secure in place with supplied 1/4-20 mounting screw. 1. Connect male and female ends of quick connect. 2. Hold end of second luminaire up to leg of uppercase luminaire aligning to groove in top of luminaire. 3. Secure second luminaire with 1/4-20 spanner screw using supplied spanner bit. Note: Do not rotate past 360 as wires will twist. Stuctura, Inc. 19922 W. 162nd St., Olathe, KS 66062 913.390.8787 www.structura.com Page 4

Troubleshooting Accessing LED and Driver 1 2 Geartray Screw 3 1. Remove acrylic lens by pushing lens upward at an angle until side comes out. 2. Remove four Philips screws (two at each end of tray) indicated in drawing above to loosen LED geartray. 3. LED driver is located on the back of the geartray. Note: Do not pin wire between geartray and inner housing when reinstalling geartray. Stuctura, Inc. 19922 W. 162nd St., Olathe, KS 66062 913.390.8787 www.structura.com Page 5