Project: Type: Qty: TC _ Series Optics Mounting Lamping Finish Voltage _ Options Series TC Triangular Column Optics Height Lamping Finish Voltage Options MA Type III MTR 5* Refractor MS Type V MTR 5* Refractor SP Type V Silver Louver WP Type V White Louver MR Type V MTR 50** Refractor feet T6 Metal Halide Metal Halide H09T6 9wT6 H050 50w H070T6 70wT6 H070 70w H00 00w (T6 only available with MA and MS refractors) HPS S050 50w S070 70w S00 00w WH White BK Black BZ Bronze SV Silver SP Specify Premium Color 0 08 0 77 7 Only available in 0v and 77v Only for Osram or Philips lamps Not available with 7v Not available with MA HS EB REC House Side Shield (80 ) Electronic Ballast GFCI Receptacle w/ weather-proof cover REC GFCI Receptacle w/ padlockable in-use cover 7 " (658mm) TEL (85) 8-00 FAX (85) 8-0 www.selux.us TC-068-0 (ss-v.6) 5" (8mm) 7" (80mm) 58" (7mm) NRTL Listed (i.e. UL, CSA) Union Made Affiliated with IBEW Local 6 E 0 /" (7mm) /8" (mm) 8. Fixture Cover - Die-cast aluminum cover is gasketed and removable to allow access for relamping.. Gasketing - Continuous gaskets provide weather-proofing, dust, and insect control at all fixture connections.. Optics - Select high pressure die-cast aluminum Type V silver or white louver; or Type III or V MTR Refractor. Formed aluminum House-Side Shield available for all Type V Refractors. Clip-on prisms create Type III distribution for MA optics.. Clear Lens - Flush tempered glass lens, interior space provided with high reflectance white finish. 5. Lamp (not shown) - Select one coated, base down, medium base ED-7 metal halide up to 00w or high pressure sodium up to 00w; or one G base T6 metal halide, up to 70w. Lamp provided by others. 6. Electroblock - (not shown) Magnetic ballast located and accessed through handhole. Pulse rated porcelain, medium base socket is mounted to diecast aluminum socket cup for maximum heat dissipation and is pre-wired to ballast. Socket cup is attached with two stainless steel screws and is easily removable for relamping. Consult factory for more detailed ballast information. 7. Column Profile - Extruded 606-T5 aluminum. 8. Access Door - Flush alumimum hand hole cover with stainless steel, vandal resistant fasteners. Exterior Luminaire Finish - Selux utilizes a high quality Polyester Powder Coating. All Selux luminaires and poles undergo a five stage intensive pretreatment process where product is thoroughly cleaned, phosphated and sealed. Selux powder coated products provide excellent salt and humidity resistance as well as ultra violet resistance for color retention. All products are tested in accordance with test specifications for coatings from ASTM and PCI. Standard exterior colors are White (WH), Black (BK), Bronze (BZ), and Silver (SV). Selux premium colors (SP) are available, please specify from your Selux color selection guide. In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the
Photometry Silver Louver / 70w MH T6 Catalog # TC-SP--H070 Test # ITL-55707 l Mirror finish with prismatic underside shields light source and controls glare. l Resulting dark light effect offers superior visual comfort. l Maximum candela of 777 at 0 from vertical l IES classification - Type III Semi-Cutoff. DOWNLOAD IES FILE: http://www.selux.com/web/files/exterior/tc-sp--h070.zip Vertical Plane through Max Candela 777 58 89 9-90 90-60 60 Longitudinal Distance in Units of Mounting Height -0 0 0 5 0 0.5..05. 5 Transverse Distance in Units of Mounting Height HID Lamp Prorate Table (ED-7 coated, medium base lamp) High Pressure Sodium Metal Halide Wattage Factor Initial Lumens Wattage Factor Initial Lumens 50 0.70 700 50 0.6 00 70.09 5800 70.00 500 00.66 8800 00.7 7800 MTR 5 Refractor / 70w MH T6 / House Side Shield Catalog # TC-MS--H070T6-HS Please consult factory. TC-068-0 (ss-v.6)
Profile " (658mm) /" (mm) " (5mm) /"(8mm) 5" (8mm) 7" (80mm) /8" (mm) 0 /" (7mm) 7" (78mm) Hand Hole Detail Tamper-proof stainless steel flathead screw 7" (78mm) 0" (5mm) Scale: /" = ' 58" (7mm) 0" (5mm) Electronic ballast located beneath panel, above handhole Hand hole 5" (7mm) Footing plan bottom view Footing plan bottom view TC-068-0 (ss-v.6)
Options Bolt Circle Use caution when setting anchor bolts. Bolts must be vertically straight and centered on dimensions shown. () / - 0 UNC x 5" Galvanized Anchor Bolts 0 /" (7mm) Ø " (Ø5mm) Conduit Ø 9 /6" (Ø6mm) Bolt Circle () @ 0 /8" (mm) Note: Adequate drainage must be provided in concrete foundation or grout. Anchor Bolt Detail /8" (.mm) / - 0 Galvanized Heavy Hex Nut / " I.D. Galvanized Flat Washers /"(mm) Thick Aluminum Base Plate /" (8mm) /8" Max. for leveling / - 0 Galvanized Heavy Hex Leveling Nut () / - 0 UNC x 5" Galvanized Anchor Bolts Concrete footing designed and supplied by others TC-068-0 (ss-v.6)
Optional Accessories GFCI Receptacle with flat cover (REC) - 0V 5A GFCI duplex receptacle with weather-proof, self-closing cover; located 6 (660mm) on center from base of pole, inline with handhole. Receptacle is intended only for portable tools or other portable equipment to be connected to outlet only when attended by operating personnel. For use with 0v applications only, for other fixture voltages, please consult factory for wire segregation requirements. GFCI Receptacle with in-use cover (REC) - 0V 5A GFCI duplex receptacle with weather-proof, self-closing padlockable in-use cover; located 6 (660mm) on center from base of pole, inline with handhole. Receptacle is intended only for portable tools or other portable equipment to be connected to outlet only when attended by operating personnel. For use with 0v applications only, for other fixture voltages, please consult factory for wire segregation requirements. /" (70mm) 5 /8" (5mm) 9 /6" (9mm) /" (58mm) /" (mm) 6 /6" (70mm) Cover shown in the closed position. Pole (Generic View) Cover shown in the closed position. Pole (Generic View) TC-068-05 (ss-v.6)