SSM Floor Heating Manifold

Similar documents
The valves can be controlled electronically by thermal actuators or act as self-acting units by means of remote temperature adjusters.

FHF Floor Heating Manifold

Premounted Midi Shunts

Integrated Valve with Presetting for Manifolds in Two-Pipe Heating Systems

SonoSensor 30 Ultrasonic flow sensor

High Capacity Valve Body, Type RA-G

Floor heating system, heating circuit with FHV-A in flow.

Manual Presetting Valves LENO MSV-B

Combined automatic balancing valve AB-PM valve DN 10-32, PN 16

Installation Guide. DEVIreg 527. Electronic Time Regulator.

X-tra Collection for designer radiators and bathroom towel rails

Manual presetting valves LENO MSV-BD

SonoMeter 30 Energy Meters

SonoMeter 30 Energy Meters

Valve bodies type RA-N with integrated presetting

Integrated Presetting Valves for Normal (013G0380) and Small (013G0381) Volume Flows

Integrated Presetting Valves - for Normal Volume Flows RA-N and for Small Volume Flows RA-U

Infocal 9 Energy calculator for heating and cooling applications

Flow controller (PN 25) AVQ - return and flow mounting

Changing pistons APP and APP 16-22

Manual presetting valve MSV-C

Assisted lift operated 2/2-way solenoid valves Type EV251B

Pre-Fabricated Flushing Bypass Assembly for Plant Applications Hero Plant DN15-150

SonoSensor 30 Ultrasonic flow meter for heating and cooling applications

RA-N Valve Bodies with Pressfit Connection and Self-Sealing Tailpiece for Two Pipe Systems

Control Card VLT FC Series

Pressure reduction controllers (PN 25) AVDS - for steam AVD - for water

Pressure relief controller AVA (PN 25)

Disassembling and assembling isave 21

Servo-operated 2/2-way solenoid valves with isolating diaphragm Type EV222B

Dynacon. Floor Heating Manifolds Floor heating manifold with automatic flow control

Flow-compensated temperature controller AVTQ DN 15

Automatic balancing valves ASV-PV DN (3rd gen.)

Oil pump type RSA. Catalogue 1. Burner Components

Dynamic Valve Type RA-DV Pressure Independent Radiator Valve

Premounted Midi Shunts

Installation Guide. VLT Real-time Clock MCB 117 VLT HVAC Drive FC 102, VLT Refrigeration Drive FC 103, VLT AQUA Drive FC 202, VLT AutomationDrive

Installation Instructions Bus Bar Kit for 6-pulse, 4-drive System VLT Series FC 102, FC 202, and FC 302. Description. Kit Part Number.

Changing pistons APP 21-43

Pressure relief controller AFA / VFG 2(1) (PN 16, 25, 40)

ATEX instruction APP S 674 pumps APP S , APP S and APP S

Pressure independent control valve with integrated flow limiter AVQM (PN 16) - return and flow mounting

Technote. Frese OPTIMIZER - pressure independent 4-pipe coil control unit. Application. Benefits. Features.

3 & 4-Way Rotary Valves

Extensions to a comprehensive product range

Flow controller with integrated control valve (PN 16) AHQM - return and flow mounting

Disassembling and assembling PAH , PAHT and PAHT G

ChangeOver6 and NovoCon ChangeOver6 - Motorized 6-port Ball Valves

SonoSelect and SonoSafe energy meters

ATEX instruction for APP / PAH PAHT G 2-90 / PAH Tech

TDU.3 floor distribution unit SK

ON/OFF zone valves AMZ 112, AMZ 113

One. The performance of your wind turbine relies on the quality of its small components. ia.danfoss.com. Brochure Mobile Hydraulic

Two- and three way valves VFG.. / VFGS 2 / VFU.. for self-acting thermostats and electrical actuators

Technote. CirCon/TemCon - thermostatic valves for domestic hot water. Application. Advantages. Functions.

Crankcase pressure regulator Type KVL

Temperature controller AVT with safety temperature monitor STM/VG(F) (PN25)

Actuator type ABNM with Theft Protection, 0-10 V Proportional

Danfoss VDHT Solenoid Valves WATER SOLUTIONS

Art.918C Pre-assembled manifold with flow meters, air

Horizontal Distribution Units - HDU Multi-port

Reliable season change

INSTRUCTIONS Servicing PAH

APP S pumps APP S / APP S / APP S 21-38

Installation Instructions In-back/Out-back Cooling Kit for D5h/D6h and D7h/D8h Enclosures VLT Series FC 102, FC 202, and FC 302

Installation Instructions 500 A Current Sensor Kit for F1 F4/F8 F13 Enclosure Sizes VLT Series FC 102, FC 202, and FC 302

Crankcase pressure regulator Type KVL

Maneurop reciprocating compressors MT - MTZ - NTZ

50% Raise your efficiency to a higher level. Equipped for silence and top performance. Optyma Plus TM New Generation

SonoSelect and SonoSafe energy meters

Parallel coupled APP pumps

Solenoid valve VDHT Standard BSP (British Standard Pipe)

CI-tronic Soft starters for Danfoss commercial compressor applications Type MCI 15C, MCI 25C, MCI 50CM-3 I-O

Technote. Frese OPTIMA - Pressure independent control & balancing valve. Application. Features. Benefits.

Installation Instructions In-bottom/Out-back Cooling Kit for E4h Drives VLT FC Series FC 102, FC 103, FC 202, and FC 302

APP pump instruction APP 21-43

Thermostatic radiator valves with presetting

Quick Reference Parts Manual Variable Displacement Motor Series 20, series powersolutions.danfoss.com

FHV control valves are flexible to use, easily installed and are available in two versions:

Nessie 3/2-Way Zone-Drain-Valves types VDM 2E, VDHT 15E, VDHT 15EC and VDH 30EC "Soft-Charge"

R134a R134a R13. 4a R134a R134a R134

H1 Pump Filter Bypass Sensor

3/2-Way Zone-Drain-Valves VDHT 2E, VDHT 15E and VDHT 15EC

ELIMINATOR Hermetic filter drier Types DML and DCL

dynacon floor heating manifold with automatic flow control

Steel butterfly valves SBFV (PN 16/25)

MAKING MODERN LIVING POSSIBLE. Phased Out Products. Technical Information. Level Controller. powersolutions.danfoss.com

Energy Recovery Device isave 21-40

How to Choose the Right Manifold for Your Project Brass vs. Copper

APP pump instruction APP and APP 16-22

Steering Priority Valve OLS 160

Danfoss Saginomiya 4 - Way Reversing Valves

The precise step to take

Starting Torque Limiter Type TCI (Soft Start)

Pressure Independent Control Valve AB QM, ½ thru 2 2½ thru 4 5 thru 10 Valve Size

Floor heating manifold with automatic flow control

Ballorex Venturi 3.1 Introduction

2/4/6.3, PAH 10/12.5, PAH 50/63/70/80/100 pumps

Advanced efficiency, precision cooling Design an HVAC system like no other

ELIMINATOR Hermetic bi-flow filter drier Types DMB and DCB

Transcription:

Application The manifold consists of a supply and return manifold. The supply manifold includes possibility for individual shut-off of each circuit on flowmeter or shut-off valve. The return manifold is equipped with integrated Danfoss presetting valves securing optimal hydraulic balance in the system. The valves can be controlled electronically by thermal actuators or act as self-acting units by means of remote temperature adjusters. The SSM manifold is used for controlling water flow in under floor heating systems. Each tube of the floor heating system is connected to the manifold, thus making it possible to control water flow or heat supply to each room in the building individually. The manifold is supplied in modules of up to 12 outlets. Ball valves are available as an option for positive shut-off between manifold and system. The SSM manifold is supplied with a manual airvent and a purge valve. Ordering Description Type Code no. Manifold set 2+2, with flowmeter SSM-2F 088U0752 Manifold set 3+3, with flowmeter SSM-3F 088U0753 Manifold set 4+4, with flowmeter SSM-4F 088U0754 Manifold set 5+5, with flowmeter SSM-5F 088U0755 Manifold set 6+6, with flowmeter SSM-6F 088U0756 Manifold set 7+7, with flowmeter SSM-7F 088U0757 Manifold set 8+8, with flowmeter SSM-8F 088U0758 Manifold set 9+9, with flowmeter SSM-9F 088U0759 Manifold set 10+10, with flowmeter SSM-10F 088U0760 Manifold set 11+11, with flowmeter SSM-11F 088U0761 Manifold set 12+12, with flowmeter SSM-12F 088U0762 Manifold set 2+2 SSM-2 088U0802 Manifold set 3+3 SSM-3 088U0803 Manifold set 4+4 SSM-4 088U0804 Manifold set 5+5 SSM-5 088U0805 Manifold set 6+6 SSM-6 088U0806 Manifold set 7+7 SSM-7 088U0807 Manifold set 8+8 SSM-8 088U0808 Manifold set 9+9 SSM-9 088U0809 Manifold set 10+10 SSM-10 088U0810 Manifold set 11+11 SSM-11 088U0811 Manifold set 12+12 SSM-12 088U0812 VDUDW102 Danfoss FHH 2015.09 1

Accessories Description Type Code no. Mounting brackets - set FHF-MB 088U0585 2 x ball valve 1 - for connection to manifold and for blocking of floor heating system 1 x thermometer 0-60 C Ø35mm - for flow/return temperature measurement FHF-BV FHD-T 088U0586 088U0029 Union, 1-088U0820 Thermal actuator, 24V, NC, Danfoss RA connection to valve TWA-A 088H3110 Thermal actuator, 230V, NC, Danfoss RA connection to valve TWA-A 088H3112 Thermal actuator, 24V, NC, with end switch, Danfoss RA connection to valve TWA-A 088H3114 Compression fittings Description Type Code no. Compression fittings for PEX tubing in accordance with ISO 15875. Max working pressure: 6 bar Test pressure: 10 bar Max. flow temperature: 95 C G ¾ internal thread Max. flow temperature given by the tube manufacturer must not be exceeded. Compression fittings for ALUPEX tubing. Max working pressure: 6 bar Test pressure: 10 bar Max flow temperature: 95 C G ¾ Internal thread Max flow temperature given by the tube manufacturer must not be exceeded. 12x2 mm 13x2 mm 14x2 mm 013G4152 013G4153 013G4154 15x2.5 mm 013G4155 16x1.5 mm 013G4157 16x2 mm 013G4156 1) 16x2.2 mm 013G4163 17x2 mm 18x2 mm 013G4162 013G4158 18x2.5 mm 013G4159 20x2 mm 013G4160 20x2.25 mm 013G4093 1) 20x2.5 mm 013G4161 12x2 mm 14x2 mm 013G4182 013G4184 15x2.5 mm 013G4185 16x2 mm 013G4186 2) 16x2.25 mm 013G4187 18x2 mm 20x2 mm 1) Compression fittings also suitable for PERT tubing in accordance with ISO 15875. 2) Compression fittings also suitable for PERT/ALU/PERT tubing. 013G4188 013G4190 20x2.25 mm 013G4093 2) 20x2.5 mm 013G4191 2 Danfoss FHH 2015.09 VDUDW102

Capacity/commissioning The pre-setting of the manifold valves determines the flow in the floor heating tubes and is therefore an important factor for obtaining optimal hydraulic balance in the system. A correct hydraulic balance is important if optimal comfort shall be achieved with a minimum of energy consumption and is easily carried out following the example shown below. Example Room 1: 1. Determine longest tube/largest room 25 m 2 2. Desired cooling (ΔT) 5 C (typical) 3. Determine heat requirement for the room 50 W/m 2 4. Conversion factor 1.16 5. Calculation of flow for the room Q (l/h) = 50 W/m2 x 25 m 2 = 216 l/h 5 C x 1.16 Room 2: 6. Determine area for the next room 15 m 2 7. Calculation of flow for the room (ΔT and heat requirement is assumed identical for the rooms in this case) Q (l/h) = 50 W/m2 x 15 m 2 = 129 l/h 5 C x 1.16 Manifold, with flowmeter Pre-setting: Room 1 N Room 2 5 Manifold, without flowmeter Pre-setting: Room 1 N Room 2 6 VDUDW102 Danfoss Danfoss FHH 2015.09 3

Presetting the manifold valves The diagram shows the capacities for each heating circuit at different presettings of the manifold valves. Based on the above calculations and capacity diagram each manifold valve is preset by rotating the red ring until the correct value on the ring is in-line with the sight mark on the valve. Operation conditions Supply manifold with flowmeter Supply manifold without flowmeter Max differential pressure 0.6 bar 0.6 bar Max working pressure 6 bar 10 bar Max test pressure 10 bar 16 bar Max flow temperature 90 C 90 C System layout 4 Danfoss FHH 2015.09 VDUDW102

Dimensions 41 L1 50 213 359 64 Type 2+2 3+3 4+4 5+5 6+6 7+7 8+8 9+9 10+10 11+11 12+12 L1 (mm) 111 161 211 261 311 361 411 461 511 561 611 VDUDW102 Danfoss Danfoss FHH 2015.09 5

Danfoss A/S Floor Heating Hydronics Ulvehavevej 61 DK-7100 Vejle Denmark Phone: +45 7488 8500 Fax: +45 7488 8501 heating@danfoss.com www.floorheating.danfoss.com Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. 6 Danfoss Danfoss FHH 2015.09 VDUDW102