HYDRUS ULTRASONIC METER

Similar documents
HYDRUS ULTRASONIC METER

CORONA E ELECTRONIC METER MULTI-JET

WESAN WPV E ELECTRONIC METER WOLTMAN

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

CORONA ER ELECTRONIC METER MULTI-JET

RAY MECHANICAL COMPACT METER. 4 MID approved class 2 from DN 15mm qp 0,6m3/h up to DN 40mm qp 10m3/h

RAY COMPACT ENERGY METER MECHANICAL

SHARKY FS 473 ULTRASONIC FLOW SENSOR

SonoMeter 30 Energy Meters

SonoMeter 30 Energy Meters

EW447-EW452 Series Mechanical Heat Meters FOR HEATING AND COOLING APPLICATIONS

WESAN WP 222. Bulk Water Meter Woltman

EW130 Series Multijet Water Meters DN15 40 FOR COLD AND WARM POTABLE WATER APPLICATIONS

WZMC-402 Ultrasonic Apartment Energy Meters

SonoSensor 30 Ultrasonic flow sensor

US-S/FFL. Ultrasonic energy meters. Function. Flexible design. Connection. Mounting. High reliability

TOPAS PMW-basic. Customer benefits. Product features

aquaconcept Product features Customer benefits

Domestic Water Meter. Elin Wasserwerkstechnik. Contact Water Meter MTM for cold water. Features

Metering systems 0578EN January 2014 Thermal energy meters, ultrasounds type for use in a boiler room GE552-1 series

Horizontal Distribution Units - HDU Multi-port

WSTH/WPTH. Woltmann type combined energy meter. Measuring distance. Function. Connection. High reliability. Mounting.

Datasheet PDCSY-MW-U. Technical Overview. Features. Product warranty and total quality commitment.

WESAN WP WOLTMAN METER

MULTICAL 62 DATA SHEET. Application

a q u a c o n c e p t Applications Features Benefits

Fluidic Oscillation Compact Heat Meter

Superstatic 440. Static Heat Meter, Static Cooling Meter. Application

Superstatic 749. Fluidic Oscillation Compact Heat Meter

Water Metering THE WORLD S MOST ACCURATE COMMERCIAL HYBRID METER

TOPAS PMW-basic Hot water meter

STUF-280W. Features: Ultrasonic Water Meter, DN15~DN40. Ultrasonic Water Meter DN50~DN600

Measuring capsule heat meter G54 / G55

Compact Static Heat Meter of High-Tech Composite

Hello, I am the new Zelsius C5 heat meter. The new generation of ultrasonic heat and cooling meters for precise energy consumption measurement.

Superstatic 440. Static Heat- and Cooling Meter. Application

Electronic Water Meters

tprime TM Series 280T

Fluidic Oscillation Compact Heat Meter of High-Tech Composite

WSTH/WPTH. Woltmann type combined energy meter. Woltmann flow meters for large nominal flows combined with calculator and temperature sensors.

Residential Water Meters

WATERFLUX 3070 Technical Datasheet

Installation & Maintenance Instructions MULTICAL 403. Supplied by. .com. Call us on +44 (0)

ULTRASONIC HEAT METER

IFX-M4-03 IFX-M4-03_D_E_2017_05_REV.0

Supercal 539 Universal compact heat meter

Screw-type and measuring capsule heat meter with IrDA interface and an interface for retrofitting external modules or with integrated communication.

Compact Heat Meters. Features. -A Pulsed output. -B M-Bus output. Accessories. UK Sales Tel: International Tel:

SonoSelect and SonoSafe energy meters

WATERFLUX 3070 Technical Datasheet

Heat Meter Integrator

Datasheet PDCSY-MW-CHM. Technical Overview. Features. Product warranty and total quality commitment. General Information.

Service instructions. MAGNA Series 2000

ASPIRO & GUARDIAN BATTERY MANAGEMENT WITH ACC EXTENDED CONTROLLER

MULTICAL 6M2. Data sheet

Supercal 539. Compact thermal energy meter

zelsius Installation and operating manual All that counts EnergyMetering

MULTICAL 602. & ULTRAFLOW 14 Cooling. Cooling meter with unlimited communication

Data sheet MULTICAL 6L2. Data loggers Info loggers Data backup in case of power failure MID-2004/22/EC EN 1434

Special voltages: Voltage >500 V AC are only permissible with external control box. 3-phase AC Voltages/frequencies. 1-phase AC Voltages/frequencies

Heat meter (E1) θ: 2 C C. DK-0200-MI qp, p/l: See display. S/N: /K8/17 Type: 603C219. Pt500-EN Battery, 1 x D-cell

MagFlux Q 8200 Series

SensoStar C. Installation and Operating Instructions Heat Meter Calculator Heat/Cooling Meter Calculator Cooling Meter Calculator

Electronic Water Meters in measuring cell design

ULTRASONIC METER FOR HEATING AND COOLING SKU-03

FH8500. Metering Solution for Custody Transfer Applications. One Step Ahead in Ultrasonic Flowmetering. Main Applications

F 90 Heat Meter Warmly recommended to cool-headed economisers

Isoil Industria a worldwide supplier of electromagnetic flowmeters Total flow control. Accurate to the drop.

Paddle-wheel flow controller with optical principle for On/Off control

T O PA S Applications Features Your benefits

M-bus impeller type heat and heat/refrigeration meters

We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control. Benefits.

SonoSelect and SonoSafe energy meters

REQUIRED TOOLS 3 mm screw driver Wrench Crosstip screwdriver

Datasheet. Multical 402. (Heating & Cooling) Supplied by. .com. Call us on +44 (0)

Operating Instructions. Pneumatic Control Valve Low Temperature. Type Series GS3

zelsius Installation and operating manual All that counts. EnergyMetering

Thermal flow sensor TFS-35

Heating Cost Allocation Valve with local acquisition of the flow temperature

HYDROMETER. Operating Instructions Edition 03/ Revision 05. Ultrasonic flowmeter type SHARKY 475 [ ] A5E HYDRO.PS.022.Q5.

Options guide. Electromagnetic flowmeters. M9xx

Magnetic Paddle Flow Sensor/Switch for Easy On/Off Control

Electronic Water Meters

BAYLAN AUTOMATED TEST BENCH

Alpha EM DC Multi-Function DC Energy Meter. Technical Datasheet. Compact DC Energy Meter

Installation & User Guide. Multical 801. (Heating & Cooling) Supplied by. .com. Call us on +44 (0)

ULTRASONIC FLOW SENSOR IFX-M4-01

Model Specifications Code Price FOTOSWITCH

Residential. Ultrasonic Cooling Meter ULTRACOLD T350 (2WR6...) A customer tailored cooling meter designed for residential needs and easy billing

SERIES PR90H PROGRAMMABLE INCREMENTAL HOLLOW SHAFT ENCODER FOR INDUSTRIAL APPLICATIONS REFERENCE PR90H - C C - C. External diameter 58 mm

Technical Datasheet. Compact DC Energy Meter. Multi-Function DC Energy Meter

Technical Information

ProMinent Sigma/ 3 Motor Diaphragm Metering Pumps

Sentinel Panametrics Custody Transfer Gas Ultrasonic Flowmeter

Cellwatch Battery Monitoring Systems

Installation and Setup Instructions

EM DC Multi-Function DC Energy Meter

ThermoPro TM Series TP10

Marsh McBirney Flo-Dar

Transcription:

HYDRUS APPLICATION Static ultrasonic water meter for accurate measuring and recording for all applications of water supply. FEATURES 4 Ultrasonic water meter with long-term stability under difficult conditions (no measurement of air and insensitive against sedimentation) 4 Higher performance than class D requirements 4 Metrological class 2 and dynamic range up to R 400 4 Compliant with MID, OIML R49 and EN 14154 4 Mounting in any installation position, no calming sections required 4 Housing with thread connection lead-free brass 4 IP68 suitable for outdoor installations 4 Certified for drinking water (KTW and ACS) 4 Wired M-Bus, Radio OMS, Radio/L-Bus and Pulse interface available 4 Radio communication based on Open Metering telegram (OMS-Generation 3, Profile A, or OMS-Generation 4, Profile B, selectable) 4 Highest data security for AMR communication 4 Displaying of error- and alarm codes, including leakage detection 4 Battery lifetime up to 16 years 4 Data logging capabilities to record up to 1.024 daily values + 32 configurable values (hourly, daily, weekly, monthly) and an annual due date

HYDRUS GENERAL HYDRUS Medium temperature range C 0.1... 90 Ambient operating temperature C 1... 70 Ambient storage temperature C -20... +70 (>35 C max. 4 weeks) Nominal pressure PN bar 16 Power supply Two 3.6 VDC lithium-batteries (only one battery with M-Bus possible) Battery lifetime T30 1 /T50 1 Up to 12 years (one battery), up to 16 years (two batteries) Battery lifetime T90 1 Up to 12 years (all interfaces) Interfaces Optical, radio 434 or 868 MHz, M-Bus, L-Bus, pulse Data storage For events and for consumption values Protection class IP 68 1 depends on the sending interval of the radio telegram, the telegram length and the ambient temperature at the installation TECHNICAL DATA DISPLAY HYDRUS Display indication LCD, 8-digit Units DN 15 - DN 32 Flow and volume (m³ + 3 digits after the comma) Units DN 40 + DN 50 Flow (m³ + 3 digits after the comma); Volume (m³ + 2 digits after the comma) Values displayed (depending on configuration) 2 Display according to approval (always on) INTERFACES - OVERVIEW Optical Radio M-Bus Volume 2 - flow - mediums temperature - display test 2 - current error and alarm status 2 - date - primary and secondary address - radio signal ON/OFF - battery lifetime 2 - accounting day - error hour counter - pulse values - software checksum 2 HYDRUS For configuration of display information and radio telegram, to switch to the various display loops 434 or 868 MHz, real data telegram (configurable), Open Metering Standard (OMS- Generation 3, Profile A, or OMS-Generation 4, Profile B, selectable) 2400 Baud (adjustable to 300 Baud), configurable telegram, cable length 1.5 m, power supply only via built-in battery L-Bus In combination with radio, cable length 1.5 m Pulse (Open collector) Two configurable pulse outputs, cable length 1.5 m VOLUME- / PULSE OPEN COLLECTOR Max. input voltage V 30 Max. input current ma 27 HYDRUS Max. voltage drop at active output V/mA 2/27 Max. current through inactive output μa/v 5/30 Max. reverse voltage without destroying outputs V 6 Pulse rates l/pulse Decadic 0.1... 100 Pulse output 1 variants Total volume or forward volume Pulse output 2 variants Forward volume, direction 3 or error Pulse duration Depending on device configuration 4 Pulse break Depending on device configuration 4 Pulse frequency Depending on device configuration 4 3 when total volume on pulse output 1, only direction possible on pulse output 2 4 detailed description on request 30.07.2018 2

HYDRUSDN 15-20 TECHNICAL DATA 5 6 Permanent flow rate Q 3 m³/h 1.6 1.6 1.6 1.6 1.6 2.5 2.5 Nominal diameter DN mm 15 15 15 20 20 15 15 Overall length L mm 110 165 170 130 190 110 165 Overload flow rate Q 4 m³/h 2 2 2 2 2 3.125 3.125 Transitional flow rate Q 2 l/h 10.24 10.24 10.24 10.24 10.24 16 16 Minimum flow rate Q 1 l/h 6.4 6.4 6.4 6.4 6.4 10 10 Starting flow rate l/h 1.3 1.3 1.3 1.3 1.3 2.6 2.6 Pressure loss at Q 3 bar 0.6 0.6 0.6 0.6 0.6 0.33 0.33 Permanent flow rate Q 3 m³/h 2.5 2.5 2.5 4 7 4 4 4 Nominal diameter DN mm 15 20 20 20 7 20 20 20 Overall length L mm 170 130 190 110 7 130 175 190 Overload flow rate Q 4 m³/h 3.125 3.125 3.125 5 5 5 5 Transitional flow rate Q 2 l/h 16 16 16 25.6 25.6 25.6 25.6 Minimum flow rate Q 1 l/h 10 10 10 16 16 16 16 Starting flow rate l/h 2.6 2.6 2.6 4.3 4.3 4.3 4.3 Pressure loss at Q 3 bar 0.33 0.25 0.25 0.3 0.3 0.3 0.3 5 at dynamic range R 250 6 further overall lengths on request 7 substitute for body length 105 mm rising pipe APPROVAL DN 15-20 Approval MID LNE 14586, OIML R49, EN 14154, TVO, KTW, ACS Dynamic range (Q 3/Q 1) - Q 3 1.6 m³/h (T30 - T50) R 160 / 200 / 250 Dynamic range (Q 3/Q 1) - Q 3 2.5 m³/h (T30 - T50) R 160 / 200 / 250 / 315 / 400 Dynamic range (Q 3/Q 1) - Q 3 4 m³/h (T30 - T50) R 160 / 200 / 250 Dynamic range (Q 3/Q 1) - Q 3 1.6-4 m³/h (T90) R 160 / 200 30.07.2018 3

HYDRUSDN 15-20 DIMENSIONS Permanent flow rate Q 3 m³/h 1.6 1.6 1.6 1.6 1.6 2.5 2.5 Nominal diameter DN mm 15 15 15 20 20 15 15 Overall length L mm 110 165 170 130 190 110 165 Counter length L1 mm 88 88 88 88 88 88 88 Counter width B mm 94 94 94 94 94 94 94 Overall length with coupling L2 mm 190 245 250 230 290 190 245 Connection thread on meter Inch G¾B G¾B G¾B G1B G1B G¾B G¾B Connection thread of coupling Inch R½ R½ R½ R¾ R¾ R½ R½ Height H1 mm 67 67 67 65 65 67 67 (approx.) kg 0.8 1 1 0.9 1.1 0.8 1 Weight with coupling (approx.) kg 1 1.4 1.4 1.3 1.5 1 1.4 Height H mm 32 32 32 34 34 32 32 Permanent flow rate Q 3 m³/h 2.5 2.5 2.5 4 7 4 4 4 Nominal diameter DN mm 15 20 20 20 7 20 20 20 Overall length L mm 170 130 190 110 7 130 175 190 Counter length L1 mm 88 88 88 88 88 88 88 Counter width B mm 94 94 94 94 94 94 94 Overall length with coupling L2 mm 250 230 290 210 230 295 290 Connection thread on meter Inch G¾B G1B G1B G1B G1B G1¼B G1B Connection thread of coupling Inch R½ R¾ R¾ R¾ R¾ R1 R¾ Height H1 mm 67 65 65 65 65 65 65 (approx.) kg 1 0.9 1.1 0.9 0.9 1.1 1.1 Weight with coupling (approx.) kg 1.4 1.3 1.5 1.3 1.3 1.7 1.5 Height H mm 32 34 34 34 34 34 34 7 substitute for body length 105 mm rising pipe 30.07.2018 4

HYDRUSDN 15-20 PRESSURE LOSS GRAPH / TYPICAL ERROR GRAPH Pressure loss graph Typical error graph 30.07.2018 5

HYDRUSDN 25-50 TECHNICAL DATA 5 6 Permanent flow rate Q 3 m³/h 6.3 6.3 6.3 6.3 6.3 10 Nominal diameter DN mm 25 25 25 25 32 25 Overall length L mm 135 150 175 260 260 135 Overload flow rate Q 4 m³/h 7.87 7.87 7.87 7.87 7.87 12.5 Transitional flow rate Q 2 l/h 50.4 50.4 50.4 50.4 50.4 80 Minimum flow rate Q 1 l/h 31.5 31.5 31.5 31.5 31.5 50 Starting flow rate l/h 10 10 10 10 10 10 Pressure loss at Q 3 bar 0.25 0.25 0.25 0.25 0.25 0.55 Permanent flow rate Q 3 m³/h 10 10 10 10 10 10 Nominal diameter DN mm 25 25 25 32 40 40 Overall length L mm 150 175 260 260 200 300 Overload flow rate Q 4 m³/h 12.5 12.5 12.5 12.5 12.5 12.5 Transitional flow rate Q 2 l/h 80 80 80 80 80 80 Minimum flow rate Q 1 l/h 50 50 50 50 50 50 Starting flow rate l/h 10 10 10 10 16 16 Pressure loss at Q 3 bar 0.55 0.55 0.55 0.55 0.25 0.25 Permanent flow rate Q 3 m³/h 16 16 16 16 25 25 Nominal diameter DN mm 40 40 50 50 50 50 Overall length L mm 200 300 270 300 270 300 Overload flow rate Q 4 m³/h 20 20 20 20 31.25 31.25 Transitional flow rate Q 2 l/h 128 128 128 128 200 200 Minimum flow rate Q 1 l/h 80 80 80 80 125 125 Starting flow rate l/h 16 16 25 25 25 25 Pressure loss at Q 3 bar 0.4 0.4 0.1 0.1 0.25 0.25 5 at dynamic range R 200 6 further overall lengths on request APPROVAL DN 25-50 Approval MID LNE 14586, OIML R49, EN 14154, TVO, KTW, ACS Dynamic range (Q 3/Q 1) - Q 3 6.3 m³/h (T30 - T50) R 40 / 80 7 / 160 / 200 Dynamic range (Q 3/Q 1) - Q 3 10 m³/h (T30 - T50) R 40 / 80 7 / 160 / 200 / 250 Dynamic range (Q 3/Q 1) - Q 3 16 m³/h (T30 - T50) R 40 / 80 / 160 / 200 / 250 / 315 8 / 400 8 Dynamic range (Q 3/Q 1) - Q 3 25m³/h (T30 - T50) R 40 / 80 / 160 / 200 / 250 / 315 / 400 Dynamic range (Q 3/Q 1) - Q 3 6.3-25 m³/h (T90) R 40 / 80 / 160 7 variant DN 25 with body length 135 mm and 150 mm only in R 80 8 not for DN 50 30.07.2018 6

HYDRUSDN 25-50 DIMENSIONS Permanent flow rate Q 3 m³/h 6.3 6.3 6.3 6.3 6.3 10 Nominal diameter DN mm 25 25 25 25 32 25 Overall length L mm 135 150 175 260 260 135 Counter length L1 mm 92 92 92 92 92 92 Counter width B mm 94 94 94 94 94 94 DIMENSIONS - THREAD...... Overall length with coupling L2 mm 255 270 295 380 380 255 Connection thread on meter Inch G1¼B G1¼B G1¼B G1¼B G1½B G1¼B Connection thread of coupling Inch R1 R1 R1 R1 R1¼ R1 Height H1 mm 84 84 84 84 84 84 (approx.) kg 1.17 1.24 1.29 1.6 1.8 1.17 Weight with coupling (approx.) kg 1.77 1.84 1.89 2.2 2.4 1.77 Height H mm 26 26 26 26 26 26 DIMENSIONS - FLANGE...... Flange diameter D mm - - - 115 140 - Hole circle diameter K mm - - - 85 100 - Number of screwholes pcs - - - 4 4 - Screwhole diameter D1 mm - - - 14 18 - Height H mm - - - 50 62.5 - Height H1 mm - - - 84 84 - Width F mm - - - 100 125 - Weight with flanges (approx.) kg - - - 3.45 4.7-30.07.2018 7

HYDRUSDN 25-50 Permanent flow rate Q 3 m³/h 10 10 10 10 10 10 Nominal diameter DN mm 25 25 25 32 40 40 Overall length L mm 150 175 260 260 200 300 Counter length L1 mm 92 92 92 92 92 92 Counter width B mm 94 94 94 94 94 94 DIMENSIONS - THREAD...... Overall length with coupling L2 mm 270 295 380 380 340 440 Connection thread on meter Inch G1¼B G1¼B G1¼B G1½B G2B G2B Connection thread of coupling Inch R1 R1 R1 R1¼ R1½ R1½ Height H1 mm 84 84 84 84 87 87 (approx.) kg 1.24 1.29 1.6 1.8 2.4 3.05 Weight with coupling (approx.) kg 1.84 1.89 2.2 2.4 3.6 4.25 Height H mm 26 26 26 26 31 31 DIMENSIONS - FLANGE...... Flange diameter D mm - - 115 140-148 Hole circle diameter K mm - - 85 100-110 Number of screwholes pcs - - 4 4-4 Screwhole diameter D1 mm - - 14 18-18 Height H mm - - 50 62.5-69 Height H1 mm - - 84 84-87 Width F mm - - 100 125-138 Weight with flanges (approx.) kg - - 3.45 4.7-6.67 Permanent flow rate Q 3 m³/h 16 16 16 16 25 25 Nominal diameter DN mm 40 40 50 50 50 50 Overall length L mm 200 300 270 300 270 300 Counter length L1 mm 92 92 92 92 92 92 Counter width B mm 94 94 94 94 94 94 DIMENSIONS - THREAD...... Overall length with coupling L2 mm 340 440 390 420 390 420 Connection thread on meter Inch G2B G2B G2½B G2½B G2½B G2½B Connection thread of coupling Inch R1½ R1½ R2 R2 R2 R2 Height H1 mm 87 87 90 90 90 90 (approx.) kg 2.42 3.05 3.9 4,05 3.9 4,05 Weight with coupling (approx.) kg 3.62 4.25 5.5 5,65 5.5 5,65 Height H mm 31 31 41 41 41 41 DIMENSIONS - FLANGE...... Flange diameter D mm - 148 163 163 163 163 Hole circle diameter K mm - 110 125 125 125 125 Number of screwholes pcs - 4 4 4 4 4 Screwhole diameter D1 mm - 18 18 18 18 18 Height H mm - 69 73.5 73.5 73.5 73.5 Height H1 mm - 87 90 90 90 90 Width F mm - 138 147 147 147 147 Weight with flanges (approx.) kg - 6.67 7.23 7.47 7.23 7.47 30.07.2018 8

HYDRUSDN 25-50 PRESSURE LOSS GRAPH / TYPICAL ERROR GRAPH Pressure loss graph Typical error graph 30.07.2018 9