Winslow Lube Oil By-Pass Type 1 Filter Service Instructions

Similar documents
Winslow Lube Oil Full-Flow Type 1 Filter Service Instructions

4 Winslow Depth Filters

Winslow Liquid Fuel Filters Standard Design Type 2 Service Instructions

LT36607 Winslow Depth Filters. Winslow Depth Filters

Sea Pro FH240 Series Filter/Separator Installation Instructions

Sea Pro FH240 Series Filter/Separator Installation Instructions

Industrial Pro FH239 Series Filter/Separator/Warmer Installation Instructions

Crankcase Ventilation Manager (CVM) Installation Instructions

Industrial Pro FH234 Series Filter/Separator/Warmer Installation Instructions

Fuel Pro Series Filter/Separator/Warmer Installation Instructions

Fuel Pro FH230 Series Filter/Separator/Warmer Installation Instructions

Odor Removal Filter. Model. Note) 1 8, , , , 3 4. Model/Free Standing Type AMF (2B)JIS 10K FF flange

Fleetguard Open Crankcase Ventilation (OCV) Kit Installation Instructions

Fittings and Tubing. Low Pressure. Fittings and Tubing - Low Pressure. Low Pressure Fittings and Tubing Features: Pressures to 15,000 psi (1034 bar)

Owner s Manual WARNING

PDE2611TCUK-ca Air Preparation. Miniature FRL series. Miniature FRL Series. Parker Hannifin Corporation Pneumatic Division - Europe

Marine Fuel Filtration. Marine FBO. Features:

Industrial Pro FH239 Series Filter/Separator/Warmer Installation Instructions

Instruction P/N:EVO1800

OPERATING AND MAINTENANCE MANUAL

1 Cylinder. 1 - Cylinder Type 3 - Cylinder Capacity 4 - Cylinder Stroke. 2 - Cylinder Options. Cylinder Accessories

Engine Emission Control 6.7L Diesel

CO01 Radiator Assembly

HD 049 HD 069 HD 172 HD 319 HD 419 HD 619 Operating pressure up to 630 bar Nominal flow rate up to 450 l/min

Bypass Oil Cleaners. Absolute Series

TECHNICAL INSTRUCTIONS FOR LIMITED SERVICE CAMPAIGN (LSC) A0N HV WATER PUMP REPLACEMENT MODEL YEAR PRIUS

5. FUEL SYSTEM 5-0 FUEL SYSTEM UXV 500

WOC-364 Installation Instructions Ranger XP Heater System

Coolant Valve. VNC Series. Cylinder actuation by pilot air

6.7L Cummins EGR Delete

High Pressure Valves, Fittings and Tubing Pressures to 65,000 psi

STEAM TRAPS. Float and Thermostatic Steam Traps (continued) Series C and X. Dimensions in. (mm)

Horton DriveMaster Fan Clutch 20.06

MODEL 5800 CONTENTS. Installation, Operation, and Maintenance Instructions 1.0 GENERAL

High Pressure Filter Kits HD 049 HD 069 HD 172 HD 319 HD 419 HD 619. Operating pressure up to 9137 psi Nominal flow rate up to gpm. 40.

REMOVAL & INSTALLATION

INSTALLATION & SERVICE INSTRUCTION MANUAL W.A. KATES FLOW CONTROLLERS FC VALVE MODELS E THRU M

Grommet pullers Soapy water Safety glasses Torque Wrench

G1814BC Eyewash, Wall Mounted, Stainless Steel Bowl and Cover

Diesel Pro FH235, FH236 and FH241 Series Filter/Separator/Warmer Installation Instructions

RESPA CF QUALITY CABIN ENVIRONMENTAL AIR UNIT FOR CARAVAN, CAMPER, RV

Installation Manual v1.1: RFE Deep Transmission Pan Dodge Ram 2500 and 3500

13. FUEL SYSTEM/CARBURETOR/

Steam Valve. Series VND. 2 Port Valve for Steam. With indicator (Option) By adopting of PTFE seal, the valve is suited for steam.

Housings and miscellaneous parts

1 6 / 2 6 S E R I E S C O M P A C T & S T A N D A R D M O D U L A R A I R P R E P A R A T I O N S Y S T E M S

Medium Pressure Valves, Fittings and Tubing Pressures to 21,000 psi

F20 & F21 QIX Particulate & Coalescing Filters

Service Handbook. High-Pressure Washer Pump

Additions, Revisions, or Updates

Stainless Steel FRLs

Tension Brakes/High Heat Capacity

Flow Controls & Accessories

High Pressure Valves, Fittings and Tubing Pressures to 65,000 psi (4,500 bar)

Sniper EFI Fuel Kits P/N 526-5/526-8 (20 ft. hose) & (40 ft. hose)

Section 3.2. Machine Maintenance - Hydraulic Oil and Tank Information

Spin-on Filters. Maxiflow Series. MAX 360 I/min - 10 bar. Low pressure filters

AN EXPLANATION OF CIRCUITS CARTER YH HORIZONTAL CLIMATIC CONTROL CARBURETER

OWNER S MANUAL D.E. CARTRIDGE. Installation Operation Parts. Models PCDE-30 PCDE-40

Installation Manual. Model T675A Engine Brakes. For Mack 6 Cylinder, 2 valve Head ENDT-673, 675, 676 & E6 Series Engines.

Model: TON AXLE JACK. March 1999 Rev.-02

Introduction Filter Heads Extended Service Interval Filters Standard Service Interval Filters

The filters for hydraulic fluids are used to protect each component in a hydraulic circuit. Port size. Micromesh 74, 105, 149

1 6 / 2 6 S E R I E S C O M P A C T & S T A N D A R D M O D U L A R A I R P R E P A R A T I O N S Y S T E M S

Maintenance Manual WITH ONE SUBMERSIBLE PUMP. Automated Fuel Maintenance System FTI-5A FUEL TECHNOLOGIES INTERNATIONAL LLC

WARCO CHEMAG SERIES GH FILTERS

Maintenance Manual. Automated. Fuel Maintenance System FTI-5A. FUEL TECHNOLOGIES INTERNATIONAL LLC

FUEL SYSTEM/CARBURETOR/FUEL PUMP

Modulating Water Valves and Bulb Wells

SECONDARY SERVICE EXTERIOR R-12DC VALVE (MODEL WITH 4 VERTICAL DELIVERY PORTS) DELIVERY COVER SECONDARY RELAY PISTON VALVE RETAINER INLET EXHAUST

WORKSHOP MANUAL. 63,4 cm³ chainsaws

T100 Hybrid/T200 Hybrid

CENTRO-MATIC PUMP, MODELS 84050, & 85460

High Pressure Valves, Fittings and Tubing Pressures to 65,000 psi

SINGLE ACTION FLUID PUMP

High Pressure Valves, Fittings and Tubing Pressures to 65,000 psi

Collision Repair Set. Form No No. 1517A 4-Ton Set. No. 1519A 10-Ton Set. Parts List & Operating Instructions for: 1519A. Part No. Item No.

OFX7 Operating Maintenance and Troubleshooting Manual L-4219

Maintenance Manual. Automated Fuel Maintenance System FTI-5A SINGLE TANK FUEL TECHNOLOGIES INTERNATIONAL

February 26, ch.12.notebook. Ch. 12. Preventative Maintenance and Troubleshooting. Feb 23 5:03 PM

NUMBER: S.M. REF.: Listed in Table ENGINE: EPA07 Series 60 DATE: October 2012 SUBJECT: REFERENCES TO THE TURBOCHARGER PURGE ROUTINE

Pneumatic. Prep-Air II 05 Series Air Preparation Units Filter, Regulator, Lubricator, and Modular Accessories Catalog 0708/USA

G1704 WideArea Eye/Face Wash, Pedestal Mounted, Stainless Steel Bowl G1704P WideArea Eye/Face Wash, Pedestal Mounted, Plastic Bowl

VNA VNB SGC SGH VNC VNH VND VCC

Additions, Revisions, or Updates

Duplex Filter Pi 4700

Duo Filter Mixer Tap Filter Installation Instructions

Models

INSTALLATION AND MAINTENANCE MANUAL FOR V-RANGE PLATE HEAT EXCHANGERS

SECTION D Engine 6.0L Diesel

Low Pressure Filter Pi 2300

AEROMOTIVE Part # & Stealth Fuel Tank Sump INSTALLATION INSTRUCTIONS

STOP IMPORTANT WARRANTY & INSTALLATION INSTRUCTIONS ATTACHED TO ACTIVATE YOUR LIMITED LIFETIME WARRANTY GO TO: CORSAPERFORMANCE.

INSTRUCTIONS FOR INSTALLATION, START-UP, AND OPERATION

CARTRIDGE FILTER SYSTEMS OWNER S MANUAL

Adams. Progressive. Description. Typical system layout using Pneumatic Pump for grease - with monitoring. Typical system

Armstrong Double Duty 6 Steam Trap/Pump Combination Installation and Maintenance

Oil Filter Module Pi 8300

ENGINE PERFORMANCE CURVE M3-135 hp ( rpm M2-120 hp ( rpm

Parker Autoclave Engineers: Fluid Components Product Catalog. February Valves, Fittings and Tubing. Pressures to 150,000 psi (10,000 bar)

Transcription:

Vent Plug (NPT) Winslow Lube Oil y-pass Type 1 ilter Service Instructions Parts List Part escription Part over ssembly and lamp Housing rain Plug ilter lement omponent Kit See Ordering Information on Page 5 omponent Kit (varies according to housing) rain Plug (NPT) UTION: These instructions are intended for use by professional mechanics who are trained in the proper use of power and hand tools, using appropriate safety precautions (including eye protection).

page 2 Introduction Winslow filter elements must be changed periodically to assure the high level of filtration efficiencies required by today's engines. y-pass filter elements should be serviced and changed based on comparative oil analyses. Significant changes in TN/TN (Total ase /Total cid ), oxidation, and nitration should be identified, monitored, and acted upon. Lube filtration is much more sophisticated than hydraulic fluid filtration. Most engine filters not only combat particulate (wear) matter, but also chemical (corrosion) contamination. The main contributor for the chemical contaminants is combustion cylinder blow-by gas. These contaminants (oxides, nitrates, soot, acids, and water) are by-products of the combustion process and are able to flow past the piston rings and enter the oil sump. Since the Winslow bypass elements absorb these contaminants without a significant increase in restriction, standard methods (a rise in restriction) used to determine an element's life cannot be used on these applications. n increase in element restriction can be used as an indicator of a plugged element in applications with an extremely high solid contamination (for example, hydraulic and machine tool fluids). or these applications, the elements should be changed out when the increase in restriction reaches 3 PSI (20.7 kpa) above the clean element restriction, however elements should be changed, at minimum, once a year. Servicing the ilter Removing the ilter lement 1. Remove the air vent plug and drain plug to drain the filter. UTION luid may be hot! 2. Vent Plug rain Plug igure 1 Removing the ir Vent and rain Plugs Loosen and remove the band clamp. and lamp Loosen Nut igure 2 Removing the and lamp

page 3 3. Remove the cover assembly. over ssembly 6. Pull the element straight up to remove. ispose of the element in an environmentally responsible manner, according to state and/or federal (P) recommendations. irty lement igure 3 Removing the over ssembly 4. Remove the O-ring cover seal. over Seal igure 6 Removing the irty lement 5. igure 4 Removing the over Seal Loosen and remove the internal component kit (varies according to housing). omponent Kit (varies according to housing) igure 5 Removing the omponent Kit leaning and Inspecting the ilter Parts and Housing 7. lean all filter parts and the inside of the filter housing, preferably with kerosene. UTION To prevent damage to your engine or equipment, do not allow dirt to fall through the opening of the element support post and into the clean outlet area. 8. 9. Replace the O-ring cover seal. (If necessary, as long as there are no permanent surface deformations, swelling, nicks, and cracks present, the seal can be reused.) Make sure that the bottom seal plate inside the filter is clean. Note: This filter is equipped with a restrictive orifice and a by-pass bleeder hole. The bleeder hole is in the hold-down assembly (internal component kit) and is visible between the coils of the spring. The bleeder hole permits a small amount of oil to by-pass the filter unit when starting cold for quicker warm-up. The bleeder also helps maintain a uniform filtering temperature throughout the unit, especially in cold weather. oth the bleeder hole and the orifice hole should be inspected at each element change to see that they are clear.

page 4 Reassembling the ilter 10. Slide the new element in place over the post. Note the direction of the arrow on the element and insert the proper end into the housing first. 12. Reinstall the drain plug. New lement own rain Plug igure 9 Reinstall the rain Plug 13. ill the filter to within.75" (19 mm) from the top of the filter housing with fresh lube oil. 14. Install a new O-ring cover seal. over Seal igure 7 Installing the New lement 11. Reinstall the internal component kit. omponent Kit (varies according to housing) igure 10 Installing the over Seal 15. Reinstall the cover assembly. over ssembly igure 8 Reinstalling the omponent Kit igure 11 Reinstalling the over ssembly

page 5 16. Replace and tighten the band clamp to approximately 50-60 in-lbs (5.7-6.8 N m). o not over-tighten. 17. Replace and tighten the vent plug. Vent Plug and lamp Tighten Nut igure 12 Reinstalling the and lamp igure 13 Replacing the Vent Plug 18. Start the engine. 19. Loosen the vent plug. When oil appears from the around the plug, tighten using a wrench. 20. Run the system until warm and check for leaks. If no leaks are detected, the filter is properly serviced and the system can be put into operation. Suggested Preventive Maintenance very ilter hange Replace the O-ring cover seal. very 12 Months heck all fittings for leaks. Ordering Information Housing* * esigned for 75 lb/in 2 (517.1 kpa) continuous operating conditions. ** ilter does not include an internal by-pass valve. n external by-pass valve can be ordered separately, if required. Table corresponds to Parts List on cover page. Replacement ilter lements Part 82421 82484 82537 82648 over ssembly escription ull-low Lube epth lement ull-low Lube epth lement ull-low Lube epth lement ull-low Lube epth lement and lamp rain Plug ilter lement omponent Kit 95240J Q80384 99955 Q52860 Q69171 82421 990436K 95252 Q57511 Q58500 Q53085 Q69173 82484 990437K 95303 Q57597 99955 Q52860 Q69217 82537 990438K 95353 Q57597 99955 Q52860 Q69172 82648 990435K ilter Specification ensely ram-packed cotton provides solid contamination control.

page 6 Specifications Housing Part ilter Oil Volume qt (L) low Rate* gal/min (L/min) lement of lements fficiency (Particulate ontrol) apacity 95240J 12 (11.4) 0.4 (1.5) 82421 1 95252 15 (14.2) 0.8 (3.0) 82484 1 95303 27 (25.6) 1.2 (4.5) 82537 1 95353 35 (33.1) 1.9 (7.2) 82648 1 apacity xceeds S Time onstraints * low rate based on 30 S oil at 180 (82.2 ) at 55 lb/in 2 (379.2 kpa). Notes: 1. esigned for 75 lb/in 2 (517.1 kpa) continuous operating conditions. 2. y-pass filter elements can be changed each time full-flow elements are changed or with every other full-flow element change. Specifications subject to change without notice. Mounting/imensions Mounting rackets (2) Inlet 0.41 (10.4) Thru Slot (4X) Outlet ll dimensions are in inches (millimeters) Housing* Part iameter Height Inlet Outlet Mounting racket Hole Horiz. Spacing Mounting racket Hole Vert. Spacing Mounting racket Max. Width 95240J 8.6 (218.4) 18 (457.2) 1/4" NPT 1/4" NPT 4.25 (108.0) 1.75 (44.5) 8.97 (227.8) 95252 8.0 (203.2) 23.0 (584.2) 1" NPT 1/2" NPT 4.25 (108.0) 1.75 (44.5) 9.41 (239.0) 95303 8.6 (218.4) 30.9 (784.9) 1" NPT 1/2" NPT 4.25 (108.0) 1.75 (44.5) 10.03 (254.8) 95353 8.6 (218.4) 40.0 (1016.0) 2" NPT 1-1/2" NPT 4.25 (108.0) 1.75 (44.5) 10.03 (254.8) * esigned for 75 lb/in 2 (517.1 kpa) continuous operating conditions. LT36073 2008 ummins iltration Printed in the U.S.. or more information, please visit us at cumminsfiltration.com