Positive Displacement Flowmeters GM007 series instruction manual

Similar documents
Positive Displacement Flowmeters GM020 series instruction manual

Positive Displacement Flowmeters GM020 series instruction manual

Positive Displacement Flowmeters GM515 series instruction manual

Positive Displacement Flowmeters GM50 series instruction manual

Positive displacement flowmeters GM001 series instruction manual

INSTRUCTION MANUAL MN7 series

POSITIVE DISPLACEMENT FLOWMETERS

POSITIVE DISPLACEMENT FLOWMETERS

The experts in fluid technology

The experts in fluid handling

OVAL GEAR FLOWMETER ELECTRONIC MODEL 019 / ¾

OVAL GEAR FLOWMETER ELECTRONIC MODEL 025 / 1

The experts in fluid technology

The experts in fluid technology

OVAL GEAR FLOWMETER MECHANICAL MODEL 012 (½ )

OVAL GEAR FLOWMETER ELECTRONIC MODEL 025 / 1. Type CR for Corrosive Applications

OVAL GEAR FLOWMETER MECHANICAL MODEL 012 (½ )

OVAL GEAR FLOWMETER MECHANICAL MODEL 075 (3 )

Operating Instructions for Oval Wheel Flowmeter. Model: DOC

OVAL GEAR FLOWMETER ELECTRONIC MODEL 006/009 (¼ )

FPD1001 thru FPD1003, FPD1102 and FPD1103, FPD1201 thru FPD1203 (includes -R Option) Positive Displacement Flowmeters

Installation & Operation Manual

OVAL GEAR FLOWMETER ELECTRONIC MODEL 006/009 (¼ )

FPD1000-HP SERIES HIGH PRESSURE Positive Displacement Flowmeters

FPD1001B thru FPD1003B, FPD1102B and FPD1103B, FPD1201B thru FPD1203B SERIES LOW FLOW Positive Displacement Flowmeters

MX06 - MX100 OVAL GEAR FLOWMETER SERIES

IM012E (ELECTRONIC) POSITIVE DISPLACEMENT FLOWMETER INSTRUCTION MANUAL

POSITIVE DISPLACEMENT FLOWMETER

MX06 - MX100 OVAL GEAR FLOWMETER SERIES APPROVED FOR USE IN HAZARDOUS AREAS

MODEL MX75 3 OVAL GEAR FLOWMETER

QSB (Q-Star) Electronics for QSE Electromagnetic Meter. Owner s Manual TABLE OF CONTENTS

QSI (Q-Star) Electronics Owner s Manual

G8 Portable Fuel Transfer Pump Owner s Manual

MODEL MX12 1/2 OVAL GEAR FLOWMETER

TURBINE HOUSING. Owner s Manual Includes Aluminum, Brass and Stainless Steel Housings and ANSI Flange Fittings

IM SERIES BI-DIRECTIONAL INSERTION FLOWMETER. Instruction Manual. To the owner SAVE THESE INSTRUCTIONS TABLE OF CONTENTS

MR 5-30 Aviation Fuel Meter Owner s Manual

VP12 High Viscosity Piston Pump

PVDF TURBINE HOUSING

STOP. Oil Pump Models L 5016, L 5116 & L Owner s Manual DO NOT RETURN THIS PRODUCT TO THE STORE! SAVE THESE INSTRUCTIONS TABLE OF CONTENTS

S T O P. Oil Pump. Models L 5016, L 5116 and L Owner s Manual DO NOT RETURN THIS PRODUCT TO THE STORE! SAVE THESE INSTRUCTIONS TABLE OF CONTENTS

Oil Pump Models L 5016, L 5116 & L 5132

P-200 Plastic Utility Pump for Petroleum Products

PVDF TURBINE HOUSING

MR 5-30 or MR 5-30N Series Fuel Meter Owner s Manual

Product Owner s Manual. 8 GPM / 30 LPM, 12-volt Fuel Transfer Pump. Model G8P

QM Series Positive Displacement Fuel Meter

STOP. LP-50DEF-BRL Lever Hand Pump System Barrel Mounting. Owner s Manual DO NOT RETURN THIS PRODUCT TO THE STORE! SAVE THESE INSTRUCTIONS

TURBINE HOUSING. Commercial Grade. Owner s Manual Includes Aluminum and Nylon

HP-100 Dual-Flo Petroleum Hand Pump

TURBINE HOUSING. Industrial Grade. Owner s Manual. Includes Stainless Steel Housings with Tri-Clover Flange Fittings SAVE THESE INSTRUCTIONS

Turbine Housing. Owner s Manual Includes Aluminum, Brass and Stainless Steel Housings and ANSI Flange Fittings

HG 20F-012E-01 OIL CONTROL GUN

LM-300 Lube Meter. Owner s Manual East 36th Street North Wichita, KS USA TEL: FAX: /10. Rev.

OVAL GEAR Medium capacity positive displacement Mechanical flowmeters. Model: ½ (15m m)

1 in., 1.5 in., and 2 in. electronic high flow meter

FM-300H and FM-300HR Electronic Disc Meter Owner s Manual

MODEL 200 MULTI-JET FLOW METER

MODEL 900 IMPELLER-TYPE FLOW METER

Positive displacement flowmeter for continuous flow measurement

ILLUSTRATED PARTS LIST

STOP. M-3130 & M-3130-RDP Series. 115/230 Volt Super Duty Fuel Pumps. Owner s Manual. M-3130-PO Pump Only DO NOT RETURN THIS PRODUCT TO THE STORE!

MODEL 1100 TURBINE FLOW METER

M-3130 & M-3130-RDP Series 115/230 Volt Super Duty Fuel Pump M-3130-ML Manual Nozzle M-3130-AL Automatic Nozzle M-3130-PO Pump Only Owner s Manual

Oil Control Handle with Mechanical Meter. Introduction. General Information. Important Information 3575-A 3575-B 3575-C 3575-D

LM-300 Lube Meter. Owner s Manual East 36th Street North Wichita, KS USA TEL: FAX: /08. Rev.

OMP Positive Displacement Flowmeters

STOP. M-150S-Methanol Pump Owner s Manual SAVE THESE INSTRUCTIONS DO NOT RETURN THIS PRODUCT TO THE STORE! TABLE OF CONTENTS

MX-SERIES OVAL GEAR FLOW METERS

EZ-8 & EZ-8 METHANOL FUEL PUMP

PENBERTHY MODELS GL AND GH GAS OPERATED JET PUMPS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

I N S T R U C T I O N M A N U A L

Stealth Electronic Manual ZTM1015 Installation & Maintenance. For Oval Gear Meter Models:

MODEL 200 MULTI-JET FLOW METER

STOP. Contractor Special Fuel Pumps. Heavy Duty Fuel Pumps. Use this manual with: M-3425CS 24-Volt DC. M Volt DC & M Volt DC

OVAL GEAR. Large Capacity Positive Displacement Mechanical Flowmeters. Models: 3 (D-750), 3 (D-1000), 4 (D-1500) & 4" (D-2500)

Model 1100 Turbine Flow Meter

M-3020 STOP. Owner s Manual SAVE THESE INSTRUCTIONS TABLE OF CONTENTS DO NOT RETURN THIS PRODUCT TO THE STORE!

Model 616 Rotating Disk Electrode Instruction Manual

Instruction Manual RZ POSITIVE DISPLACEMENT FLOWMETERS 2AU

Liquid Turbine Flowmeter

Instruction Manual. RZ Positive Displacement Flowmeters 2AU

Stealth Electronic Manual ZTM1010 Installation & Maintenance. For Oval Gear Meter Models:

OVAL GEAR. Medium Capacity Positive Displacement Mechanical Flowmeters. Models: 1 (D-150), 1½ (D-250), 2 (D-450) & 2" (D-580)

PFS Rotameter. Variable Area Flowmeter. Instruction Manual PFS-RM200, RM230, RM250

Type 2712 (8630) Continuous TopControl System. General data Compatibility Materials of wetted parts Body Rotor Shaft Seal

JET METER INSTRUCTIONS

M-1115S Series Fuel Pump

M-3020 FUEL PUMP OWNER S MANUAL TABLE OF CONTENTS DO NOT RETURN THIS PRODUCT TO THE STORE! Please contact. Great Plains Industries, Inc.

OMP POSITIVE DISPLACEMENT FLOWMETERS

NECO Pumping Systems

OVAL GEAR. Medium capacity positive displacement Pulse flowmeters I N S T R U C T I O N M A N U A L

PENBERTHY FROST PROOF EXTENSION INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

OVAL GEAR Medium capacity positive displacement flowmeter

POSITIVE DISPLACEMENT FLOW METERS

I N S T R U C T I O N M A N U A L 3 (080), 3 (080E), 4 (100), & 4 (100E)

Ph: (07) Fax: (07) Pump Manual

Operating Instructions & Parts Manual. Oil Control Gun. Models 48UJ82, 48UJ83, 48UJ84, 48UJ85 and 48UJ86

HM860 FLOWMETER OPERATOR S MANUAL DO NOT USE OR OPERATE THIS EQUIPMENT UNTIL THIS MANUAL HAS BEEN READ AND THOROUGHLY UNDERSTOOD

Agxcel GX12i Chemical Injection System

Transcription:

MS499G 0603 0003 Positive Displacement Flowmeters GM007 series instruction manual GM007 Pulse Meter From serial No. CXXXX

To the owner Thank you for purchasing a GPI GM GPI by telephone or fax.] Series Flow Meter. Please take a few minutes to read through this manual The GPI GM Series Flow Meter has before installing and operating your incorporated the oval rotor principal meter. If you have any problems with into its design. This has proven to be a the meter, refer to the maintenance reliable and highly accurate method and trouble shooting sections of this of measuring flow. Exceptional manual. repeatability and high accuracy over a wide range of fluid This manual contains connection and viscosities and flow rates are features operating instructions for the GM007 of the GM Series flow meter design. Series meters with pulse outputs. For The low pressure drop and high models with displays an additonal pressure rating means the GM Series instruction manual is supplied. [If you flow need further assistance, contact your local GPI representative or contact Important Information meter is suitable for both gravity and pump (in line) applications. The GPI GM Series flow meters are available in aluminum, 316 stainless steel, or PPS. Standard rotors are made from PPS (Polyphenylene Sulfide Resins) with optional 316 stainless steel rotors available for either stainless steel or aluminium models. clean will dramatically effect flow meter performance. the meter must be isolated and the line pressure reduced. PLEASE READ THIS INFORMATION CAREFULLY BEFORE USE! Before use, confirm the fluid to be used is compatible with the meter (refer to the GPI fluid compatibility chart), or consult your local GPI distributor for advice. To prevent damage to the meter slowly fill the system with fluid (this will prevent damage caused by air purge). Note: Failure to do this could damage the meter. For pump applications, turn off the pump at the end of each day. The reed switch pulse unit can cause inaccurate rate counts when used with high speed counters. It is advised that a debounce circuit be used or alternatively use the hall effect sensor option. To prevent damage from dirt or foreign matter, GPI recommends a Y or Basket type 60 mesh strainer be installed as close as possible to the inlet side of the meter (if required contact GPI for further information). Maintenance can be carried out to the liquid crystal displays and pulse units without removing or isolating the meter from the line. When maintenance to any other part of the meter is required, Note: When a strainer is installed it should be regularly inspected and cleaned. Failure to keep the strainer 1

Installation Bypass Line Flow Inlet 1] GPI recommends that when setting up pipework for meter installations a bypass line be included in the design. This provides the facility for a meter to be removed for maintenance without interrupting production. (See Fig.1) installation) The register assembly may be orientated to suit the individual installation. Note: Incorrect installation can cause premature wear of meter components. Flow Outlet Strainer 1 2] Use thread sealant on all pipe threads. 7] Do not over tighten meter connections. 3] For pump applications ensure pipe work has the appropriate working pressure rating to match the pressure output of the pump. 8] It is important that after initial installation you fill the line slowly, high speed air purge could cause damage to the rotors. 4] Install a wire mesh strainer (Y or basket type 60 mesh as close as possible to the inlet side of the meter. 5] Ensure that the meter is installed so that the flow of the liquid is in the direction of the arrows embossed on the meter body. 6] The meter can be installed in any orientation as long as the meter shafts are in a horizontal plane. (Refer to Fig.2 for correct 9] Test the system for leaks. 10] Check the strainer for swarf or foreign material, after the first 200 litres check periodically, particularly if the flow rate decreases. Operation When fluid passes through the meter, the rotors turn. The magnets which are located in the rotors will pass across the pulser circuit board (containing either Reed switches or Hall Effect sensors). A signal is received which is then sent by the Pulse Circuit Board (PCB) to the relevant LC display or receiving instrument. Do Not Install Meter This Way 2 2

Electrical Connections Reed Switch Connections for PCB Terminals - refer Fig.3 Contact rating 15VA Maximum Voltage 150VDC Configuration 1 2 x pulse outputs Configuration 2 Link 2 & 3 for double pulse output 3 Hall Effect Sensor Connections - refer Fig.4 LCD Versions Pulse Versions Only 1 x Hall Effect Sensor 1 x Reed Switch 2 x Hall Effect Sensor 1 - Reed Switch 2 - Reed Switch 3 - HE Common - 4 - HE Signal 5 - HE Supply + 1 - HE Supply + 2 - HE 1 Signal 3 - HE Common - 4 - HE 2 Signal 5 - HE Ground Hall Effect Voltage 4.5 to 24 VDC Current Draw Minimum 4.6mA Output NPN Open Collector 25mA 4 Service Instructions Disassembly Ensure that the fluid supply to the meter is disconnected, and the line pressure is released before disassembly, with the exception for repair or maintenance to the LC Display or PCB where there is no necessity to isolate the meter from the flow. Refer to the exploded parts diagram on pages 5. 1a] Units with Pulse Caps; Undo the conduit connector, remove pulse cap (item 9) and remove the wires from the pulse terminal board (item 5). 1b] Standard LC Display; Mark the display orientation with a marking pen, unscrew the four large screws on top of the LC Display. 3

Carefully separate the LC Display from the plastic housing and shafts at 90 o to each other (refer disconnect the wires from the Fig. 5) and check their operation by pulse terminal block. turning either of the rotors. If the rotors are not in mesh correctly or 2] Remove the mounting adaptor plate do not move freely, remove one of and gasket (Item 8). the rotors and replace correctly at 90 o to the other rotor. Re-check the 3] Loosen the four cap screws (Item 7) operation of the rotors. and nuts that hold down the meter cap (Item 4), remove the screws 4] Replace the o ring (Item 2) into and nuts and lift off the cap. groove in the meter cap, if the o ring has grown or is damaged in 4] Remove the o ring (Item 2) from the any way replace it with a new part. o ring groove in the meter cap (Item 4). 5] Replace the meter cap. Insert the 5] Remove rotors (Item 3). cap head screws (Item 7) and fix nuts and tighten in the sequence 1, Reassembly 3, 2, 4 1] Before reassembling check the condition of the rotors (replace if 6] The replacement of cables and necessary). connectors are a reversal of the disassembly procedure, replace 2] Check that the smooth side of the conduit fitting if required. When rotors (not the plug side) is facing replaceing the Standard LC Display, you when inserting the rotors, the confirm the orientation marks made smooth side of the rotor is the on disassembly are aligned then magnet side. There is no difference screw the register into place. between rotor one or rotor two. 7] Test the meter by turning the rotors 3] Replace the rotors (Item 3) onto the with a finger or by applying very low Meter Trouble Shooting Rotor #1 5 Rotor #2 Rotors must be at 90 o to each other. air pressure ( a good breath) to one end of the meter, before returning the meter to the line. Pulse Circuit Board (PCB) Notes: The pulse PCB (Item 5) is fitted with (A) two reed switches; (B) hall effect sensors; or (C) one reed switch and one hall effect sensor. The PCB board is fastened to the meter cap (Item 4) by two screws and stand off s. All care and caution should be taken when removing or handling the PCB as both the reed switch and hall effect sensor are fragile. Individual reed switches or hall effect sensors are not available as replacement parts and are only available with the PCB (Item 5). TROUBLE Fluid will not flow through meter Reduced flow through the meter Meter reading inaccurate Meter not giving a pulse signal CAUSE a] Foreign matter blocking rotors b] Line strainer blocked c] Damaged rotors d] Meter connections over tightened e] Fluid is too viscous a] Strainer is partially blocked b] Fluid is too viscous a] Fluid flow rate is too high or too low b] Fluid is too viscous c] Excess wear caused by incorrect installation a] Faulty hall effect sensor b] Faulty reed switch c] Magnets failed REMEDY a] Dismantle meter, clean rotors (Strainer must be fitted in line) b] Clean strainer c] Replace rotors (Strainer must be fitted in line) d] Re-adjust connections e] See specifications for rated viscosity a] Clean strainer b] See specifications for rated viscosity a] See specifications for flow range b] Bleed air from system c] Check meter body and rotors. Replace as required. a] Replace PCB Board b] Replace PCB Board c] Replace rotors 4

Meter Parts Listing 1 2 3 4 5 6 7 8 9 10 Key: u Indicates recommended Spare Parts to stock 33 Item No. No. Off. Rec. Parts Part or Set (Order from this column only) Part Description 1 1 MS351B Meter Body 1 BSP (PPS) & St St Shafts 1 1 MS351N Meter Body 1 NPT (PPS) & St St Shafts 1 1 MS352B Meter Body 1 BSP (PPS) & Hastalloy Shafts 1 1 MS352N Meter Body 1 NPT (PPS) & Hastalloy Shafts 2 1 u BS235TE O Ring (Teflon) Encapsulated 2 1 u BS235V O Ring (Viton) 3 2 u MS370S Rotors PPS (Polyphenylene Sulfide Resins) 3 2 MS370CPS Rotors PPS ** 4 1 MS405R Meter Cap (PPS) 5 1 u MS368-R PCB (Standard Reed Switch) 5 1 u MS344-HE PCB (Hall Effect Sensor) 5 1 MS368-R/HE PCB ( 1 Reed Switch & 1 Hall Effect Sensor) 6 2 MS284S PCB Board Screws 7 4 u MS350S Meter Cap Screws (Stainless Steel) 8 1 u MS340 Pulser Cap Gasket 9 1 MS406R Pulser Cap (PPS) 16mm Conduit Thread 9 1 MS406R-N Pulser Cap (PPS) 1/2 NPT Thread 10 2 MS347S Pulser Cap Screw (Stainless Steel) 11 1 MS37 Warning Label (Not Shown) 12 1 Specify plate details Legend Plate (Not Shown) inc. Hammer Screws 33 1 MS111 Earthing Screw 34 4 MS497S Nut - Stainless Steel - Not Shown, recessed in body **For PPS Meters fitted with Hastalloy shafts only Meter Specifications Flow Ranges (Litres/min. - US Gall./min.) Above 5 Centipoise Below 5 Centipoise Accuracy of Reading Maximum Viscosity Maximum Operating Pressure Maximum Operating Temperature Pulse Type Pulses Per Litre/US Gallon 3 to 80 / 0.8 to 21 8 to 70 / 2 to 18.5 +/- 0.5% 1000 Centipoise 1000 kpa/ 150 PSI/ 10 BAR 80 C/ 176 F Dual Reed Switches or Hall Effect Sensor or combination HE Sensor/Reed Switch 52 or 104/197 or 394 5

Meter Dimensions Pulse Meter Dimensions 120mm 70mm 100mm 108mm Warranty Great Plains Industries, Inc. Limited Warranty Policy Great Plains Industries, Inc., 5252 East 36th Street North, Wichita, Kansas USA 67220-3205, hereby provides a limited one year warranty against defects in material and workmanship on all products manufactured by Great Plains Industries, Inc. This warranty shall extend to the purchaser of this product and to any person to whom such product is transferred during the warranty period. The warranty period shall begin on the date of the original new equipment purchase. Warrantor s obligation hereunder shall be limited to repairing defective workmanship or replacing or repairing any defective part or parts. This warranty shall not apply if: a.)the product has been altered or modified outside the warrantor s duly appointed representative; b.)the product has been subjected to neglect, misuse, abuse or damage or has been installed or operated other than in accordance with the manufacturer s operating instructions. To make a claim against this warranty, notice of claim must be given in writing to the company at its address below no later than 30 days after the expiration of the warranty period. Such notice shall identify the defect in the product. The company shall, within 14 days of receipt of such notice, notify the customer to either send the product, transportation prepaid, to the company at its office in Wichita, Kansas, or to a duly authorized service center. The company shall perform all obligations imposed on it by the terms of this warranty within 60 days of receipt of the defective product. GREAT PLAINS INDUSTRIES, INC. EXCLUDES LIABILITY UNDER THIS WARRANTY FOR DIRECT, INDIRECT, INCIDENTAL AND CONSEQUENTIAL DAMAGES INCURRED IN THE USE OR LOSS OF USE IF THE PRODUCT WARRANTED HEREUNDER. The company herewith expressly disclaims any warranty of merchantability or fitness for any particular purpose other than for which it was designed. This warranty gives you specific rights and you may also have other rights which vary from U.S. state to U.S. state. 18mm NOTE: In compliance with MAGNUSON MOSS CONSUMER WARRANTY ACT - Part 702 (governs the resale availability of the warranty terms). 30mm