Positive Displacement Flowmeters GM515 series instruction manual

Similar documents
The experts in fluid technology

Positive Displacement Flowmeters GM020 series instruction manual

Positive Displacement Flowmeters GM007 series instruction manual

Positive displacement flowmeters GM001 series instruction manual

The experts in fluid technology

Installation & Operation Manual

Positive Displacement Flowmeters GM020 series instruction manual

Positive Displacement Flowmeters GM50 series instruction manual

The experts in fluid handling

The experts in fluid technology

POSITIVE DISPLACEMENT FLOWMETERS

INSTRUCTION MANUAL MN7 series

OVAL GEAR FLOWMETER MECHANICAL MODEL 012 (½ )

OVAL GEAR FLOWMETER MECHANICAL MODEL 012 (½ )

POSITIVE DISPLACEMENT FLOWMETERS

OVAL GEAR FLOWMETER MECHANICAL MODEL 075 (3 )

FPD1000-HP SERIES HIGH PRESSURE Positive Displacement Flowmeters

FPD1001 thru FPD1003, FPD1102 and FPD1103, FPD1201 thru FPD1203 (includes -R Option) Positive Displacement Flowmeters

OVAL GEAR FLOWMETER ELECTRONIC MODEL 019 / ¾

OVAL GEAR FLOWMETER ELECTRONIC MODEL 025 / 1

OVAL GEAR FLOWMETER ELECTRONIC MODEL 006/009 (¼ )

OVAL GEAR FLOWMETER ELECTRONIC MODEL 006/009 (¼ )

FPD1001B thru FPD1003B, FPD1102B and FPD1103B, FPD1201B thru FPD1203B SERIES LOW FLOW Positive Displacement Flowmeters

OVAL GEAR FLOWMETER ELECTRONIC MODEL 025 / 1. Type CR for Corrosive Applications

MX06 - MX100 OVAL GEAR FLOWMETER SERIES

Operating Instructions for Oval Wheel Flowmeter. Model: DOC

TURBINE HOUSING. Owner s Manual Includes Aluminum, Brass and Stainless Steel Housings and ANSI Flange Fittings

MX06 - MX100 OVAL GEAR FLOWMETER SERIES APPROVED FOR USE IN HAZARDOUS AREAS

G8 Portable Fuel Transfer Pump Owner s Manual

IM012E (ELECTRONIC) POSITIVE DISPLACEMENT FLOWMETER INSTRUCTION MANUAL

PVDF TURBINE HOUSING

MR 5-30 Aviation Fuel Meter Owner s Manual

PVDF TURBINE HOUSING

POSITIVE DISPLACEMENT FLOWMETER

STOP. Oil Pump Models L 5016, L 5116 & L Owner s Manual DO NOT RETURN THIS PRODUCT TO THE STORE! SAVE THESE INSTRUCTIONS TABLE OF CONTENTS

Oil Pump Models L 5016, L 5116 & L 5132

S T O P. Oil Pump. Models L 5016, L 5116 and L Owner s Manual DO NOT RETURN THIS PRODUCT TO THE STORE! SAVE THESE INSTRUCTIONS TABLE OF CONTENTS

VP12 High Viscosity Piston Pump

QSB (Q-Star) Electronics for QSE Electromagnetic Meter. Owner s Manual TABLE OF CONTENTS

MR 5-30 or MR 5-30N Series Fuel Meter Owner s Manual

QM Series Positive Displacement Fuel Meter

Turbine Housing. Owner s Manual Includes Aluminum, Brass and Stainless Steel Housings and ANSI Flange Fittings

QSI (Q-Star) Electronics Owner s Manual

Product Owner s Manual. 8 GPM / 30 LPM, 12-volt Fuel Transfer Pump. Model G8P

TURBINE HOUSING. Industrial Grade. Owner s Manual. Includes Stainless Steel Housings with Tri-Clover Flange Fittings SAVE THESE INSTRUCTIONS

P-200 Plastic Utility Pump for Petroleum Products

HP-100 Dual-Flo Petroleum Hand Pump

MODEL MX75 3 OVAL GEAR FLOWMETER

TURBINE HOUSING. Commercial Grade. Owner s Manual Includes Aluminum and Nylon

MODEL MX12 1/2 OVAL GEAR FLOWMETER

IM SERIES BI-DIRECTIONAL INSERTION FLOWMETER. Instruction Manual. To the owner SAVE THESE INSTRUCTIONS TABLE OF CONTENTS

OVAL GEAR Medium capacity positive displacement Mechanical flowmeters. Model: ½ (15m m)

HG 20F-012E-01 OIL CONTROL GUN

OVAL GEAR. Large Capacity Positive Displacement Mechanical Flowmeters. Models: 3 (D-750), 3 (D-1000), 4 (D-1500) & 4" (D-2500)

Oil Control Handle with Mechanical Meter. Introduction. General Information. Important Information 3575-A 3575-B 3575-C 3575-D

STOP. LP-50DEF-BRL Lever Hand Pump System Barrel Mounting. Owner s Manual DO NOT RETURN THIS PRODUCT TO THE STORE! SAVE THESE INSTRUCTIONS

LM-300 Lube Meter. Owner s Manual East 36th Street North Wichita, KS USA TEL: FAX: /10. Rev.

OVAL GEAR. Medium Capacity Positive Displacement Mechanical Flowmeters. Models: 1 (D-150), 1½ (D-250), 2 (D-450) & 2" (D-580)

FM-300H and FM-300HR Electronic Disc Meter Owner s Manual

Stealth Electronic Manual ZTM1015 Installation & Maintenance. For Oval Gear Meter Models:

Positive displacement flowmeter for continuous flow measurement

MODEL 200 MULTI-JET FLOW METER

LM-300 Lube Meter. Owner s Manual East 36th Street North Wichita, KS USA TEL: FAX: /08. Rev.

EZ-8 & EZ-8 METHANOL FUEL PUMP

STOP. M-150S-Methanol Pump Owner s Manual SAVE THESE INSTRUCTIONS DO NOT RETURN THIS PRODUCT TO THE STORE! TABLE OF CONTENTS

PENBERTHY MODELS GL AND GH GAS OPERATED JET PUMPS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

ILLUSTRATED PARTS LIST

MODEL 900 IMPELLER-TYPE FLOW METER

I N S T R U C T I O N M A N U A L 3 (080), 3 (080E), 4 (100), & 4 (100E)

STOP. M-3130 & M-3130-RDP Series. 115/230 Volt Super Duty Fuel Pumps. Owner s Manual. M-3130-PO Pump Only DO NOT RETURN THIS PRODUCT TO THE STORE!

PFS Rotameter. Variable Area Flowmeter. Instruction Manual PFS-RM200, RM230, RM250

NECO Pumping Systems

M-3130 & M-3130-RDP Series 115/230 Volt Super Duty Fuel Pump M-3130-ML Manual Nozzle M-3130-AL Automatic Nozzle M-3130-PO Pump Only Owner s Manual

Liquid Turbine Flowmeter

M-1115S Series Fuel Pump

M-3020 STOP. Owner s Manual SAVE THESE INSTRUCTIONS TABLE OF CONTENTS DO NOT RETURN THIS PRODUCT TO THE STORE!

MODEL 200 MULTI-JET FLOW METER

Ph: (07) Fax: (07) Pump Manual

ORIGINAL INSTRUCTIONS G715A. Pneumatic-hydraulic Riveter E. Warner Ave Santa Ana, CA

STOP. Contractor Special Fuel Pumps. Heavy Duty Fuel Pumps. Use this manual with: M-3425CS 24-Volt DC. M Volt DC & M Volt DC

MODEL 1100 TURBINE FLOW METER

Agxcel GX12i Chemical Injection System

M-3020 FUEL PUMP OWNER S MANUAL TABLE OF CONTENTS DO NOT RETURN THIS PRODUCT TO THE STORE! Please contact. Great Plains Industries, Inc.

Atlas PV-9WP Addendum

FR1118- P10. User s Manual

Operating Instructions & Parts Manual. Oil Control Gun. Models 48UJ82, 48UJ83, 48UJ84, 48UJ85 and 48UJ86

Air Operated Double Diaphragm Pump. M-Pump ½ Metallic Non Metallic Pump INSTALLATION, OPERATION & MAINTENANCE MANUAL

Stealth Electronic Manual ZTM1010 Installation & Maintenance. For Oval Gear Meter Models:

P SERIES PUMPS. 18mm Versions Nickle-Aluminum Bronze Models: P , P , P , P , P , P , P

CONTENTS. VIKING PUMP, INC. A Unit of IDEX Corporation Cedar Falls, IA USA SECTION TSM 710.1

PENBERTHY FROST PROOF EXTENSION INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Type 2712 (8630) Continuous TopControl System. General data Compatibility Materials of wetted parts Body Rotor Shaft Seal

Instruction Manual RZ POSITIVE DISPLACEMENT FLOWMETERS 2AU

OMP POSITIVE DISPLACEMENT FLOWMETERS

MX-SERIES OVAL GEAR FLOW METERS

Instruction Manual. RZ Positive Displacement Flowmeters 2AU

AMB100L-im-issue INSTRUCTION MANUAL 240V DIESEL MINI BOWSER AMB100L AMB100L

DO NOT INSULATE BELOW THIS LINE. * For sizes 1/2" to 1 1/2" add 2 1/2" to 'C' dimension.

Operating Manual High Viscosity Dispense Valve Item #

TITAN FLOW CONTROL, INC.

Transcription:

MS103G 0603 0004 Positive Displacement Flowmeters GM515 series instruction manual GM515 Mechanical meter From serial No. CXXXX

To the owner Please take a few minutes to read thorugh this manual before installing and operating your meter. If you have any problems with the meter, refer to the maintenance and trouble shooting sections of this manual. This manual contains connection and operating instructions for GM515 meters with mechanical displays. If you need further assistance, contact your local representative or distributor. This Flow Meter has incorporated the Oval rotor principal into its design. This has proven to be a reliable and highly accurate method of measuring flow. Exceptional repeatability and high accuracy over a wide range of fluid viscosities and flow rates are features of the Oval rotor design. The low pressure drop and high pressure rating means Oval rotor flow meters are suitable for both gravity and pump (in line) applications. Flow meters are available in either aluminium, Bronze or 316 stainless steel. Standard rotors are made from PPS (Polyphenylene Sulfide Resins) with optional 316 stainless steel rotors available for both stainless steel and aluminium models. The GM515 series Mechanical displays have a resettable batch totaliser and non-resettable accumulative totaliser. Important Information PLEASE READ THIS INFORMATION CAREFULLY BEFORE USE! Before use, confirm the fluid to be used is compatible with the meter. Refer to the industry compatibility charts, or consult your local representative for advice. To prevent damage from dirt or foreign matter it is recommended that a Y or Basket type 60 mesh strainer be installed as close as possible to the inlet side of the meter. Note: When a strainer is installed it should be regularly inspected and cleaned. Failure to keep the strainer clean will dramatically effect flow meter performance. Note: To prevent damage caused by air purge slowly fill the system with fluid. To prevent pressure build up turn off the pump at the end of each day. Operation When fluid passes through the meter, rotors turn. The gear located on top of one of the rotors drives the mechanical registers gear train which provides an accurate readout. 1

Installation Bypass Line Flow Inlet 1] It is recommended that when setting up pipework for meter installations a bypass line be included in the design. This provides the facility for a meter to be removed for maintenace without interrupting production. (See Fig.1) 2] Use thread sealant on all pipe threads. For flanged versions appropriate companion flanges and gaskets are required. 3] For pump applications ensure pipe work has the appropriate working pressure rating to match the pressure output of the pump. 4] Install a wire mesh strainer (Y or basket type) as close as possible to the inlet side of the meter. 5] Ensure that the meter is installed so that the flow of the liquid is in the direction of the arrows embossed on the meter body. orientation as long as the meter shafts are in a horizontal plane. (Refer to Fig.2 for correct installation) The register assembly may be orientated to suit the individual installation. Note: Incorrect installation can cause premature wear of meter components. 7] Do not over tighten meter connections. 8] It is important that after initial installation you fill the line slowly, high speed air purge could cause damage to the rotors. 9] Test the system for leaks. 10] Check the strainer for swarf or foreign material, after the first 200 litres check periodically, particularly if the flow rate decreases. Flow Outlet Strainer 1 6] The meter can be installed in any Do Not Install Meter This Way 2 2

Service Instructions Rotor #1 Disassembly Ensure that the fluid supply to the meter is disconnected, and the line pressure is released before disassembly. Refer to the exploded parts diagram on pages 5 and 6 for item numbers. 1] Remove the four screws (Item 17) located on the face of the register. Then remove the face plate cover including register assembly. 2] Remove the four register mounting screws (Item 15). Then remove the lower half of the register housing. 3] Remove the six cover plate screws (Item 12) and remove the cover plate (Item 11). 4] Remove the eight meter cap screws (Item 5) and remove the meter cap (Item 4). 5] Remove rotors (Item 3). Reassembly 1] Clean all components before reassembly. 2] Before reassembly check the condition of the rotors (Item 3). Replace if necessary. 3] Replace the rotor (with the gear) on the short shaft in the housing then place the 2nd rotor onto the shaft so as the rotors are at 90 to each other. (Refer Fig 3). Check rotor operation by turning either of the rotors. If the rotors are not in mesh correctly or do not move freely remove one of the rotors and replace it correctly at 90 to the other rotor. Recheck the operation of the rotors. 4] Inspect the gears (Item 6) in the meter cap (Item 4) for wear. (Replace if required, refer to spare parts on page 10). 5] Replace the o-ring (Item 2) into the groove in the meter cap, if the o- ring has been distorted or is damaged in any way replace it with a new part. 6] Replace the meter cap, making sure the locating pins line up with the holes in the meter cap and the gear on the rotor meshes correctly with the gear in the meter cap (Item 4). Insert the allen screws (Item 5) and tightn in the sequence 1, 4, 2, 5, 3, 6. 7] Inspect the bevel gear (Item 13), o- ring (Item 10), and output gear (Item 7) for wear or damage. (Replace faulty components if necessary). 8] Replacement of output shaft, bush and seal. Disassembly a.remove the bevel gear. b.remove the circlip and push out the output shaft assembly, including washer. c.remove the seal. d.carefully press out the output shaft bush (If required). Assembly a.carefully press the new output shaft bush into place (Use Loctite Primer 747, as per instructions, Rotor #2 Rotors must be at 90 o to each other. 5 followed by sealant Loctite 262). b.insert a new seal into the groove of the output shaft bush. c.replace the output gear and washer and replace the circlip to lock the output gear shaft into place. d.replace the bevel gear (Item 13) and tighten the grub screw onto flat face of shaft. 9] Place the o-ring (Item 10) into the groove in the cover plate (Replace the o-ring seal if required). 10] Place the cover plate onto the meter. Replace the cover plate screws and tighten the six cap head screws (Item 12) firmly. 11] Place the lower cover plate of the register into position. Replace the four screws (Item 15) and tighten. 12] Position the register correctly on top of the lower register cover. Replace the four screws (Item 17) and tighten. 13] Test the meter by turning the rotors with a finger or by applying low air pressure (No more than a good breath) to one end of the meter, before returning meter to the line. 3

Meter Trouble Shooting TROUBLE Fluid will not flow through meter Reduced flow through the meter Meter reading inaccurate Fluid flows but no reading on meter TROUBLE SHOOTING GUIDE CAUSE a] Foreign matter blocking rotors b] Line strainer blocked c] Damaged rotors d] Meter connections over tightened e] Fluid is too viscous a] Strainer is partially blocked b] Fluid is too viscous a] Fluid flow rate is too high or too low b] Fluid is too viscous c] Excess wear caused by incorrect installation a] Bevel gear is loose on shaft b] Rotor drive gear is damaged c] Transmission gears damaged d] Register gears damaged REMEDY a] Dismantle meter, clean rotors (Strainer must be fitted in line) b] Clean strainer c] Replace rotors (Strainer must be fitted in line) d] Re-adjust connections e] See specifications for maximum viscosity a] Clean strainer b] See specifications for maximum viscosity a] See specifications for minimum and maximum flow rates b] Bleed air from system c] Check meter body and rotors. Replace as required. Refer to installation instructions a] Tighten grub screws b] Replace rotor c] Replace gears d] Replace register assembly Fluid leaks into register a] Seal won or damaged on the cover plate a] Replace seal (Check seal compatibility with fluid) 4

Meter Parts Listing 1 5 1 2 4 10 11 13 12 14 15 16 3 5 6 7 8/9 8A/9A O-RING ONLY KEY: u Indicates recommended Spare Parts to stock Bold text indicates Stainless Steel Model parts. 17 Item No. No. Off. Rec. Parts Part or Set (Order from this column only) Part Description 1 1 MS192B Meter Body 1 1/2 BSP (Aluminium) 1 1 MS192N Meter Body 1 1/2 NPT (Aluminium) 1 1 MS190B Meter Body 1 1/2 BSP (Stainless Steel) 1 1 MS190N Meter Body 1 1/2 NPT (Stainless Steel) 1 1 MS192F Meter Body 1 1/2 ANSI 150lb Flange (Aluminium) 1 1 MS192D Meter Body 1 1/2 DIN16 Flange (Aluminium) 1 1 MS190F Meter Body 1 1/2 ANSI 150lb Flange (S/Steel) 1 1 MS190D Meter Body 1 1/2 DIN16 Flange (S/Steel) 2 1 u BS243TES O Ring (Teflon) 2 1 u BS243VS O Ring (Viton) 3 2 u MS92S Rotors PPS (Polyphenylene Sulfide Resins) Brass hub 3 2 u MS92-1S Rotors (316 Stainless Steel) 3 2 u MS92-2S Rotors PPS with Stainless Steel hub 3 2 u MS92HS High Viscosity Rotors (PPS) 3 2 u MS92HS-2S High Viscosity Rotors (PPS) S/Steel hub 4 1 MS222S Meter Cap Liters (Aluminium) 4 1 MS222US Meter Cap US Gallons (Aluminium) 4 1 MS223S Meter Cap Liters (Stainless Steel) 4 1 MS223US Meter Cap US Gallons (Stainless Steel) 5 6 u MS116S Meter Cap Screws (Standard) 5 6 u MS180S Meter Cap Screws (Stainless Steel) 6 1 u MS295S Complete Gear Set - Liters 6 1 u MS317S Complete Gear Set - US Gallons 7 1 u MS77S Output Gear & Shaft Assembly 8 1 u MS78VS Coverplate Seal/Bush Set Viton 8A 1 u OR42CS Solvent o-ring (Chemraz) 9 1 u MS78C Coverplate Seal/Bush Set Solvent 9A 1 u V7-007S O-ring (Viton) 5

Meter Parts Listing Item No. No. Off. Rec. Parts Part or Set (Order from this column only) Part Description 10 2 u BS145TES O-ring (Teflon) 10 2 u BS145VS O-ring (Viton) 11 1 MS99S Coverplate (Aluminium) includes bush 11 1 MS99-1S Coverplate (Stainless Steel) includes bush 12 6 u MS312S Coverplate Screws - Litre Model 12 6 u MS313S Coverplate Screws (Stainless Steel)- Litre Model 13 1 u MS83S Bevel Gear Set 14 1 MS140RS Bottom Register Coverplate 15 4 u MS111S Mounting Screws 16 1 u MS141RS incl 15 & 17 Register Assembly complete - Litres 16 1 u MS141RUS incl 15 & 17 Register Assembly with complete - US Gallons 17 4 u MS129S Register Body Screws 18 1 Customer to specify model Legend Plate (Not Pictured) includes Hammer Screws 19 1 MS37 Warning Label (Not Pictured) Meter Dimensions Mechanical Meter Dimensions 205mm 152mm 115mm 178mm 150mm 240mm Meter Specifications 230mm Flow Ranges (Liter per minute/us Gallons per minute) Above 5 Centipoise 10 to 250/ 2.6 to 66 Below 5 Centipoise 15 to 235/ 4 to 62 Accuracy of Reading +/- 1% Maximum Viscosity* 1000 Centipoise Maximum Operating Pressure** 1800kPa / 260 PSI / 18 BAR Operating Temp. Range Alum. -10 C / 14 F to 80 C / 176 F Stainless Steel -10 C / 14 F to 120 C / 248 F * Unless High Viscosity Rotors are fitted ** Meter conforms to PED 97/23/EC CAT 1. 55mm 6

Warranty Great Plains Industries, Inc. Limited Warranty Policy Great Plains Industries, Inc., 5252 East 36th Street North, Wichita, Kansas USA 67220-3202, hereby provides a limited one year warranty against defects in material and workmanship on all products manufactured by Great Plains Industries, Inc. This warranty shall extend to the purchaser of this product and to any person to whom such product is transferred during the warranty period. The warranty period shall begin on the date of the original new equipment purchase. Warrantor s obligation hereunder shall be limited to repairing defective workmanship or replacing or repairing any defective part or parts. This warranty shall not apply if: a.) the product has been altered or modified outside the warrantor s duly appointed representative; b.) the product has been subjected to neglect, misuse, abuse or damage or has been installed or operated other than in accordance with the manufacturer s operating instructions. To make a claim against this warranty, notice of claim must be given in writing to the company at its above address no later than 30 days after the expiration of the warranty period. Such notice shall identify the defect in the product. The company shall, within 14 days of receipt of such notice, notify the customer to either send the product, transportation prepaid, to the company at its office in Wichita, Kansas, or to duly authorized service center. The company shall perform all obligations imposed on it by the terms of this warranty within 60 days of receipt of the defective product. GREAT PLAINS INDUSTRIES, INC. EXCLUDES LIABILITY UNDER THIS WARRANTY FOR DIRECT, INDIRECT, INCIDENTAL AND CONSEQUENTIAL DAMAGES INCURRED IN THE USE OR LOSS OF USE IF THE PRODUCT WARRANTED HEREUNDER. The company herewith expressly disclaims any warranty of merchantability or fitness for any particular purpose other than for which it was designed. This warranty gives you specific rights and you may also have other rights which vary from U.S. state to U.S. state. NOTE: In compliance with MAGNUSON MOSS CONSUMER WARRANTY ACT - Part 702 (governs the resale availability of the warranty terms).