TOTALFLOW Technical Bulletin 82

Similar documents
DV Tecnologia Company Group

AUTOMOTIVE DEVICES QUICK REFERENCE GUIDE

FUSE TECHNOLOGY Ambient temperature

Charles Sullivan, Associate Professor, Thayer School of Engineering at Dartmouth

EE 741 Over-voltage and Overcurrent. Spring 2014

PROTECTING RECHARGEABLE LI-ION AND LI-POLYMER BATTERIES in Portable Electronics

CradlePoint Vehicle Best Practices Installation Guide

Features. V max (Vdc) I max (A) typ. (W) P d

MHP-TA RESETTABLE TCO DEVICE For Lithium Battery Protection

Ceramic PTC Thermistor:

PORTABLE MEDICAL DEVICES PROTECTION QUICK REFERENCE GUIDE

POLY-FUSE Resettable PTCs. 2920L Series. Surface Mount > 2920L Series E R RoHS. Description

Safety technique. Emergency Stop Module BH 5928, BI 5928

Why Orion BMS Internal Fuses Blow

Installation Instructions

Positive Temperature Coefficient (PTC) Data Sheet

VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

Fig 1. Circuit Breakers

Surface Mount > 0603L Series. Description. Features. Applications. Maximum Time To Trip Current (A) P d typ. (W)

POWER PROFET A simpler solution with integrated protection for switching high-current applications efficiently & reliably

Electrical Protection

Exercise 3-3. Basic Operations of GTO Thyristors EXERCISE OBJECTIVES

Surface Mount > 1812L Series. Description. Features. Applications. I max (A) typ. (W) P d. Current (A)

Features. Samples. I max (A) P d. typ. (W)

Transformer Protection

011 Circuit Protection/Fuse Panel

FUZETEC TECHNOLOGY CO., LTD.

ELEC-E8421 Components of Power Electronics. Protection of Power Semiconductor Devices

Exercise 1-5. Current Protection Devices EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Circuit breakers

Techniques for Protecting Smart Sweeping Robots

BATTERY PACK OVERVIEW WHITE PAPER

Miniature circuit breaker Application guide

Computer Game machines Automotive Portable electronics Telephony and broadband Industrial controls Multimedia Mobile phones Battery

Surface Mount > 1210L Series. Description. Features. Applications. Maximum Time To Trip Current (A) P d typ. (W) Time (Sec.)

ECET Distribution System Protection. Overcurrent Protection

MF-R/250 Series - Telecom PTC Resettable Fuses

USER MANUAL. 10 January Certification of constancy of performance CNBOP No CPR-0454 Certificate of admittance CNBOP No.

Power Electronics. POWERSWITCH Semiconductor Relay / - Contactor With Load Circuit Monitoring PH 9270

Maintenance Manual 13 AMPERE POWER SUPPLY 19A704647P1-P3. Mobile Communications LBI-31801C

Radial Leaded PTC Resettable Fuse : FRX F

Safe & Secure Series Electric Actuator with Internal Battery Back-up Installation, Operation & Maintenance Manual

VC-30 / VC-40 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

Presented to the IAPMO Standards Review Committee on December 9, 2013

Fuseology. Fuse Holders, Fuse Blocks, Power Distribution Blocks & Surge Suppression. Optima Fuse Holders & Overcurrent Protection Modules.

DPX15-xxWDxx Dual Output: DC-DC Converter Module 9.5 ~ 36VDC, 18 ~ 75VDC input; ±5 to ±15 VDC Dual Output; 15 Watts Output Power

Industrial Chargers and

Installation Instructions

The estimation of the polymer fuses features

LESSONS LEARNED FORSMARK EVENT Presented To IEEEE

PolySwitch Resettable PTCs Surface Mount > LoRho Series. Low Rho SMD Series. Description

Shunt Capacitor Bank Protection in UHV Pilot Project. Qing Tian

Burn Characteristics of Visco Fuse

DPX30-xxSxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; 3.3 to 28 VDC Single Output; 30 Watts Output Power

(typ.) (Range) ±18 330# 89 MPW MPW

011 Circuit Protection/Fuse Panel

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

FSMD Page 8-12

Uninterruptible power supplies (UPS)

6300 Series Owner/Operator Manual

DPX30-xxDxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power

Operations Manual. Zero Speed Switch Sensor Model ZS09P

TOTALFLOW Technical Bulletin 59 Lead Acid Battery Inspection and Maintenance Procedures

4.0 OPERATION Type ITH-T Relay

n For use in telecommunication circuit applications requiring low current protection with high surge tolerance

PO Box 2484 Rowville Vic 3178

DH50 SERIES. DATASHEET Rev. A

TVS Diode Arrays (SPA Diodes) SP2502L Series 3.3V 75A Diode Array. Lightning Surge Protection - SP2502L Series. RoHS Pb GREEN.

Protectors. Manual motor. Types MS116, MS132, MS45x, MS49x. MS Series. Manual motor protectors. Type MS116. Type MS132. Type MS45x.

Specification Status: Released

1333 (SERIES B & C) TROUBLESHOOTING GUIDE

Efficiency (typ.) (Range) Output Voltage Current. Input Current Load VDC VDC ma ma ma(typ.) ma(typ.) ma(typ.

Features. Figure 1. Block Diagram. Figure 2. Input - Output DC Voltage

Redundancy unit CP-C.1-A-RU Accessory for CP-C.1 range power supplies

Guidelines for Modernizing Existing Electrical Switchgear in LV and MV Networks

ES5 Security Theory/Regulations Answer Schedule

Specification Status: Released

3. OPERATION 2.1. RESTRAINT CIRCUIT 2.6. INDICATING CIRCUIT 2.2. OPERATING CIRCUIT 2.7. SURGE PROTECTION CIRCUIT 2.3.

VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S

2920L Series. POLY-FUSE Resettable PTCs. Surface Mount > 2920L Series. Description

Micropac Industries, Inc.

1332 TROUBLESHOOTING GUIDE. Remarks: If this function is not appropriate for the application, it can be eliminated by turning off DSWl, switch 3.

This Specification Data Sheet brought to you by: Trinity Blvd. Fort Worth, Texas /

DPX30-xxWDxx DC-DC Converter Module 10 ~ 40VDC, 18 ~ 75VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power

CB-005N Circuit Board

Starts, stops and protects. Emotron TSA Softstarter

L007 LIQUID LEVEL FLOAT SWITCH. Side-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

DPX30-xxWSxx DC-DC Converter Module 10 ~ 40VDC, 18 ~ 75VDC input; 3.3 to 28VDC Single Output 30 Watts Output Power

Voltage limiting device HVL

SafeGear TM Motor Control Center Arc resistant metal-clad construction Motor Control Center Descriptive bulletin

AC..CS SAFETY WIREWOUND RESISTOR

Output Current Input Current Reflected Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S033

Document: PRODSPEC-140 Revision: G DCN No Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger

SolidMatrix 1206 Fast Acting Surface Mount Fuses

Technical Regulations 2019

DRB-1 Series Instruction Manual

SECURITRON POWER SUPPLIES MODELS: BPS-12-3, , 9 AND 15; BPS-24-2, 3, 4, 6 AND 10 OPERATION AND INSTALLATION INSTRUCTIONS

Uninterruptible Power System

Phoenix DX Sensorless AC Vector Drive. 3 HP to 3500 HP

Phocos CML-V2. Solar charge controller. User Manual (English) Dear customer,

OVERLOAD PROTECTION. All electrical circuits must have some means of protecting against overload.

Transcription:

TOTALFLOW Technical Bulletin 82 PTC Fuses Being Added To Totalflow Electronic Circuit Boards Totalflow Technical Bulletin Version 1.0, Revision AA (12 June 2000) ABB Automation Inc. Automation ABB Automation Inc. P.O. Box 8900 Bartlesville, Oklahoma 74005 USA Telephone (918) 338-4888 Telefax (918) 338-4699 Internet www.abb.com/usa K:\Documentation\Techbulls\tekbul82.doc

1. Purpose To describe the addition of PTC fuses to Totalflow electronic circuit boards. This bulletin will also define these components and discuss the added benefits of PTC devices. Description In order to maintain intrinsic safety classification and protect critical circuits from exposure to excessive current, Totalflow uses fuses on electronic circuit boards. Statistics on returned parts indicate that certain fuses are being blown repeatedly, causing excessive amount of boards to be returned. Therefore, Totalflow has modified some of our electronic boards in order to add PTC- Positive Temperature Coefficient, switch fuses. As shown in the provided FUSE TABLE, we have replaced some fast acting fuses on 64XX and 67XX devices with PTC fast acting fuses. However, not all fuses have been replaced. We have replaced the fuses that we believe are most often blown. We will continually evaluate our fuse implementation to discern if further steps are required. The remainder of this document is intended to help you better understand Totalflow s fuse utilization and provide instruction on PTC fuses. How does the polymer PTC effect work? A polymer PTC device comprises a polymer matrix that is loaded with carbon black particles to make it conductive. Since it is conductive it will pass a given amount of current. If too much current is passed through the device, the device will begin to heat by I 2 R effect. As the device heats it will expand. As it expands, the carbon particles will separate and the resistance of the device will increase. This will cause the device to heat faster and expand more, further raising the resistance. When the internal temperature of the device reaches 125 C, the change in resistance increases dramatically. This increase in resistance is sufficient to substantially reduce the current in the circuit. A small amount of current will still flow through the device sufficient to maintain the temperature of the device and keep the PolySwitch device at the high resistance level. When the power is cycled off and the fault removed the PolySwitch device is allowed to cool. As the device cools, it contracts to its original shape and reconnects the carbon particles thus lowering the resistance of the device to a level where it can hold the current as specified for the device. This cycle can be repeated multiple times. What are the basic differences between a PolySwitch device and a fuse or other circuit protection device? How does a PolySwitch device work with overvoltage devices to provide protection? The most obvious difference between a PolySwitch device and a fuse is the feature of resettability. While both products provide overcurrent protection, a single PolySwitch device can provide this protection multiple times, whereas after the fuse has provided its protection, it must be replaced for the circuit to function properly. The typical performance of a PolySwitch device is similar to that of a time delay fuse. Both devices need to have the thermal derating of the device taken into account, but the PolySwitch device does not need to have an I 2 t derating since it does not degrade as a fuse does under start-up conditions. When comparing a PolySwitch device to a bi-metallic circuit breaker the main difference is latching, not resettability. Both devices are resettable, but the bi-metallic circuit breaker can reset itself even when the fault is still present. This can lead to large EMI spikes on resetting and when tripping and potentially reconnecting a fault condition that could damage equipment and be unsafe. The PolySwitch device will latch in the high-resistance state until the fault is cleared and the power is cycled off and on. 06/15/00 2 Technical Bulletin 82

PolySwitch devices differ from ceramic PTC devices in their initial resistance, time to react to fault events, and size. Both products are resettable but the PolySwitch device, compared to a ceramic PTC device of the same hold current, will typically react (trip) much faster than the CPTC because the PolySwitch device is smaller and has a lower resistance. The most common application where PolySwitch devices are used in combination with overvoltage devices are the telecom applications. Here devices such as thyristors, gas discharge tubes, MOVs, or diodes provide protection against lightning and power cross faults. The PolySwitch device protects the protection device in some of these fault events and can also provide protection against other over current events. How many times can you trip a PolySwitch device at the maximum voltage and interrupt currents? Each PolySwitch device is rated to handle a specified operating voltage. Each device can withstand a specified interrupt current as a fault event. To obtain UL recognition, the device must be tripped at least 6,000 times and still exhibit PTC characteristics. For the telecom devices TR, TS, TC, they have a rating for maximum surge voltage for specific fault events that can occur in telecom applications. This may be as few as ten times or as many as several hundred times with the device still meeting the original specification values. Designers should keep in mind that the PolySwitch device is intended to protect against faults and failures and is not intended for use in applications where it will be expected to be tripped as the normal mode of functioning. What is the failure mode of a PolySwitch device? The typical failure mode of the device is to fail in a high resistance state. This means that the device does not return to its original low resistance value such that it can maintain the original specified hold current. In order to achieve UL recognition, the device must be tripped 6,000 times and still exhibit PTC behavior and stay in a tripped state for over 1000 hours while exhibiting PTC behavior. If a device is subjected to fault events that exceed its rated voltage and current, the device can fail in a fashion that can exhibit arcing and rupture into flame. Abuse beyond the expected use, as outlined by such things as the UL test requirements, can also cause this failure mode to occur as these devices are not recommended for intrinsically unsafe environments. Will I still be able to blow the non-resettable fast acting fuses? Yes. Examples of such things that might blow non-resettable fuses include: Inserting a communications module with power applied to the device Removing or Attaching an AMU with power applied to the device Battery voltage wired with reverse polarity Battery voltage removed with high charge voltage (> 17Vdc) still present 06/15/00 3 Technical Bulletin 82

In General, what is protected by the PTC fuses? Circuit outputs providing VBATT (Battery Voltage) and SWVBATT (Switched Battery Voltage) to communications equipment and other end devices. When an existing board is returned for repair, will it also be upgraded with PTC fuses? Yes. Returned boards will be brought up to most current revision level, including the addition of PTCs as indicated in the FUSE TABLE. 2. Conclusion Addition of the PTC devices should reduce failures pertaining to field wiring errors on Totalflow s electronic boards. We continue to review our products and make improvements to provide reliable products to our customers. If you have any questions concerning this bulletin call Totalflow Customer Services at (918) 338-4819 or 1 (800) 442-3097 option 2, 2. 06/15/00 4 Technical Bulletin 82

FUSE TABLE Totalflow Electronic Circuit Boards Board Application Fuse Number 2017333 EXIO-PIRTU F501 FA 500mA inductor Type Value Purpose Possible cause of premature failure F502 FA 250mA zener 2017245 RTU F1 FA 500mA inductor 2017220 EXIO/RTU TERM F2 FA 250mA zener F1 FA 125mA F2 FA 4A F3 FA 4A Analog output Digital 1-4 output Digital 5-8 output 2012803 6600 F2 FA 500mA inductor F3 FA 4A Communications module inserted / Communications module inserted / Voltage greater that 26V supplied to AOPWR input when using external supply for DO power when using external supply for DO power Communications card inserted / 2015333 w/ptcs 2015382 w/ptcs F4 FA 250mA zener F5 FA 62.5mA 6400 F500 FA 4A (*) F501 FA 500mA inductor F502 FA 62.5mA F503 FA 250mA zener F504 FA 4A (*) 6700 F1 FA 4A (*) F2 FA 4A (*) F3 FA 4A (*) Term SWVBAT F504 FA 500mA inductor F505 FA 250mA zener F506 FA 62.5mA Communications card inserted / connector attached / with battery connector attached / with battery connector attached / with battery connector attached / with battery FA: Fast Acting SB: Slow Blo (*) Fuses which have been replaced with 2.5A PTC's 06/15/00 5 Technical Bulletin 82