PAH / PAHT / PAHT G pumps

Size: px
Start display at page:

Download "PAH / PAHT / PAHT G pumps"

Transcription

1 Lenntech Tel Fax Instruction PAH / PAHT / PAHT G pumps

2 Instruction Pump instruction PAH / PAHT / PAHT G Table of Contents 1. Identification System design Closed-system design Open-system design General guidelines for calculation of pressure losses General comments on Building up the pump unit Mounting Direction of rotation Orientation Protection from too high pressures Connections Initial start-up Operation Water quality Temperature Pressure Dry running Disconnection Storage Water hydraulic systems, water recirculated Open-ended systems with water supply from tank Open-ended systems with direct water supply Service Recommended service intervals General information Inspection of pump parts How to inspect the pump Identification 2 180R9277 / 521B1246 / DKCFN.PI.011.C2.02 /

3 2. System design 2.1 Closed-system design A B C D E Inlet line: Dimension the inlet line to obtain minimum pressure loss (large flow, minimum pipe length, minimum number of bends/ connections, and fittings with small pressure losses). Inlet filter: Install the inlet filter (1) in front of the tank (2). Please consult the Danfoss filter data sheet for guidance on how to select the right filter. Monitoring pressure switch: Install the monitoring pressure switch (3) in front of the filter (1). Set the maximum inlet pressure to 2 barg (29.0 psig). The monitoring pressure switch will stop the pump (5) if inlet pressure is higher than 2 barg (29.0 psig), indicating that the filter element must be changed. Monitoring temperature switch: Install the monitoring temperature switch (4) in the tank. Set the temperature value according to technical data, item 4. The monitoring temperature stops the pump if inlet temperature is higher than the set value. Hoses: Always use flexible hoses (6) to minimize vibrations and noise. F Inlet pressure: In order to eliminate the risk of cavitation and other pump damage, pump inlet pressure must be maintained according to specifications described in item 4, technical data. G Non-return valve (7): Should be installed after the outlet to prevent pump backspin, which may ruin the pump. H Pressure relief valve: As the Danfoss PAHT pump begins to create pressure and flow immediately after start-up regardless of any counter pressure, a pressure relief valve (8) should be installed to prevent system damage. I System water filling: To ensure proper filtration of new water (10) supplied to the system, always use the J filling valve (9). Minimum level switch: Install the minimum level switch (11) above the outlet of the reservoir. The level switch must stop the pump if the water in the reservoir is below the switch, which indicates that the reservoir is empty Reservoir PI M PI System R9277 / 521B1246 / DKCFN.PI.011.C2.02 /

4 2.2 Open-system design A B C D Inlet line: Dimension the inlet line to obtain minimum pressure loss (large flow, minimum pipe length, minimum number of bends/ connections, and fittings with small pressure losses). Inlet filter: Install the inlet filter (1) in front of the PAHT pump (2). Please consult the Danfoss filter data sheet for guidance on how to select the right filter. Monitoring pressure switch: Install the monitoring pressure switch (3) between the filter and the pump inlet. Set the minimum inlet pressure according to specifications described in item 4, technical data. The monitoring pressure switch stops the pump if inlet pressure is lower than the set minimum pressure. Monitoring temperature switch: Install the monitoring temperature switch (4) between the filter and the pump, on either side of the monitoring pressure switch. Set the temperature value according to technical data, item 4. The monitoring temperature switch stops the pump if inlet temperature is higher than the set value. E F Hoses: Always use flexible hoses (5) to minimize vibrations and noise. Inlet pressure: In order to eliminate the risk of cavitation and other pump damage, pump inlet pressure must be maintained according to specifications described in item 4, technical data. G Non-return valve (6): Should be installed after the outlet to prevent pump backspin, which may ruin the pump. H Pressure relief valve: As the Danfoss PAHT pump begins to create pressure and flow immediately after start-up regardless of any counter pressure, a pressure relief valve (7) should be installed to prevent system damage. Note: If a non-return valve is mounted in the inlet line, a low-pressure relief valve is also required between the non-return valve and the pump to protect against high-pressure peaks. 1 4 PI M 2 PI System R9277 / 521B1246 / DKCFN.PI.011.C2.02 /

5 2.3 General guidelines for calculation of pressure losses The suction conditions can be optimized according to below guidelines. In smooth pipes and hoses In 90 bends 2.4 General comments on Filtration A good filtration is vital to ensure a long and trouble free life of the pump. When selecting a filter or strainer, please note that filter materials should be compatible with water, i.e. should neither corrode or dissolve. Also be aware of the electrochemical series of the applied materials. Main filter must have a fineness of 10 µm abs. β 10 5,000. The pressure loss across the filter should be monitored. Please contact the Danfoss Sales Organization for further filter details. Automatic pressure equalization between tank and surroundings must be ensured. Inlet from the water supply (the return line) and inlet to the pump should be placed in opposite ends of the tank to calm and deaerate the water, and to ensure optimum opportunity for particles to settle. Pump suction line should be placed above the tank bottom in order to prevent settled particles from being led into the pump. Water tank Must be made of corrosion-proof material such as stainless steel or plastic and must be sealed to prevent entrance of impurities from the environment. 180R9277 / 521B1246 / DKCFN.PI.011.C2.02 /

6 We recommend a separation ( wall ) to separate the inlet from the outlet end of the tank. Monitoring It is recommended to continuously monitor the following conditions: Water level in the tank Filter contamination Pressure (inlet- and outlet side of the pump) 3. Building up the pump unit 3.1 Mounting A: Elastic coupling B: Bell housing C: Motor shaft If alternative mounting is desired, please contact the Danfoss Sales Organization. Choose proper tolerances to ensure an easy mounting of the elastic coupling without use of tools. 3.2 Direction of rotation Is indicated by means of an arrow at the label of the pump. Please take care to observe the recommended length tolerances of the chosen coupling, as an axial force on the pump shaft must be avoided. 3.3 Orientation The pump can be mounted/orientated in any direction R9277 / 521B1246 / DKCFN.PI.011.C2.02 /

7 3.4 Protection from too high pressures The pump should be protected against too high pressure by means of a pressure relief valve or a bypass/unloading valve placed on the pressure side. The valve should be placed as close to the pump as possible. The opening characteristics of the valve must not result in peak pressures higher than 200 bar (2900 psi). The valve outlet must not be connected directly to the pump suction line. It shall be connected directly to the tank. 3.5 Connections P: Pressure T: Tank C: Bleeding D: Parallel key 5 x 5 x 20, DIN 6885 Thread size Max tighten torque PAH / PAHT / PAHT G PAH / PAHT / PAHT G P T C P T C G 1 4 x 11 G 1 2 x 15 M6; Allen key G 1 4, NV6 G 3 8 x 15 G 3 4 X 17 4 mm 14 deep 25 Nm 25 Nm 5 Nm 25 Nm 25 Nm 15 Nm Recommended torque values refer to steel washers containing a rubber sealing element. 180R9277 / 521B1246 / DKCFN.PI.011.C2.02 /

8 4. Initial start-up Before start-up, loosen the top bleeding plug C. When water appears from the bleeding plug, retighten the plug. With its inlet line connected to the water supply or the tank, the pump is now started with open outlet port. At the initial start of the system, the pump should be run without pressure for about 5 minutes, thus removing possible impurities from pipes, hoses, etc. However, the system should be flushed before start-up. Warning: Make sure that the direction of rotation of the electric motor corresponds to the direction of rotation of the pump. Otherwise the pump will be damaged if a check valve is placed between pump and tank. 5. Operation 5.1 Water quality Water of drinking water quality, confirming to the EEC directive 98/83/EC and without abrasive sediments. Please contact Danfoss sales organization in case of doubt. 5.2 Temperature 5.5 Disconnection If the inlet line is disconnected from the water supply, the pump will be emptied of water through the disconnected inlet line. When starting up again, follow the bleeding procedure described under section 4: Initial start up. Fluid temperature Ambient temperature Storage temperature Min. +2 C to max. +50 C Min. 0 C to max. 50 C Min. -40 C to max. +70 C 5.6 Storage When preparing the pump for long-term storage or for temperatures below the freezing point, flush the pump with an anti-freeze medium type monopropylene glycol to prevent internal corrosion or frost in the pump. For further information on anti-freeze media, please contact the Danfoss Sales Organization. In case of lower operating tempera tures, please contact the Danfoss Sales Organization. 5.3 Pressure The inlet pressure must be between min. 0 barg/ 0 psig and max. 4 barg/60 psig. The use of pump outside this range damage the pump. Max. pressure on the pump s outlet line should be limited at 140 barg (2030 psig) continuously. Short-term pressure peaks (e.g. in connection with closing of a valve) of up to 200 barg (2900 psig) are acceptable. NB: The pump unit should include a pressure gauge on the high pressure side. 5.4 Dry running When running, the pump must always be connected to the water supply in order to avoid damage if it should run dry. Recommended procedure Water hydraulic systems, water recirculated 1. Disconnect the power pack from the system. 2. Empty the tank of water. Fill up the tank with anti-freeze medium to a level well above the suction line. 3. Start up the power pack and, for a couple of minutes, in a closed loop system let the anti-freeze medium run back to tank through the pressure relief valve or the bypass valve. 4. Empty the tank of the anti-freeze medium. Empty the pump through the lower bleeding plug. The pump is now protected against internal corrosion and frost. In systems with water tank it is recommended to build in a level gauge in the tank to avoid the risk of running dry R9277 / 521B1246 / DKCFN.PI.011.C2.02 /

9 5.6.2 Open-ended systems with water supply from tank. 1. Empty the tank of water and empty the pump housing through the lower bleeding plug. When the pump is empty, retighten the plug. 2. Through the upper bleeding plug, fill the pump housing with anti-freeze medium. Pour anti-freeze medium into the tank. Connect a hose to the outlet of the pump and lead the other end of the hose back to tank. 3. Quickly start and stop the pump. Make sure that the pump does not run dry. The pump is now protected against internal corrosion and frost Open-ended systems with direct water supply. 1. Disconnect the water supply to the pump. 2. Through the lower bleeding plug, empty the pump housing of water and close it again. 3. Connect the pump to a tank of e.g. 25 litre/ 6 gal. of anti-freeze additive. Connect a hose to the inlet port of the pump and via another hose return the flow from the outlet port port to the tank with anti-freeze additives. 4. Quickly start and stop the pump. Make sure that the pump does not run dry. The pump is now protected against internal corrosion and frost. 6. Service The Danfoss PAHT/PAHT G pumps are designed for long periods of service-free operation to provide customers with low maintenance and life cycle costs. Provided that the pumps are installed and operated according to Danfoss specifications, the Danfoss PAHT/PAHT G pumps typically run 8,000 hours between service routines. However, the service schedule for your PAHT/PAHT G pump may vary according to the application and other factors. The life of a pump may be greatly shortened if Danfoss recommendations concerning system design and operation are not followed. Other factors that affect pump performance and lifetime include: running the pump at speeds outside specifications supplying the pump with water at temperatures higher than recommended running the pump at inlet pressures outside specifications running the pump at outlet pressures outside the specifications. In our experience, poor filtration is the number one cause of pump damage. 7. Recommended service intervals 7.1 General information This guideline provides information on the recommended service intervals for the PAHT/ PAHT G pumps. The recommendation is based upon good engineering practice and on experience gained from operation even under extreme conditions. The recommendation is for guidance only. 7.2 Inspection of pump parts Danfoss recommends to inspect the pumps after 8,000 hours. Typical signs of wear are seen on the contact/sliding surfaces in the pumps. If the pumps must run for additional 8,000 hours, the following parts will have to be inspected: Pistons Retainer plate, ball and bearing Valve plate Port plate Sealings If there are any wear marks on the parts they need to be replaced. If service inspection due to the application is complicated, the plant operator can decide to extend the service interval by evaluating the following deviations: Sound - does the pump have any unusual sounds? Electric motor power consumption and speed compared with measurement made in the past. Pressure/flow according to measurements made in the past? We advise that the above mentioned parameter during the extended service interval is inspected for every 500-2,000 hours beyond the 8,000 hours. The pump must in any case be inspected after maximum 16,000 hours or 2 years. 7.3 How to inspect the pump Service manuals are available on the internet 180R9277 / 521B1246 / DKCFN.PI.011.C2.02 /

10 Lenntech Tel Fax Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved R9277 / 521B1246 / DKCFN.PI.011.C2.02 /

APP pump instruction APP and APP 16-22

APP pump instruction APP and APP 16-22 MAKING MODERN LIVING POSSIBLE Instruction APP pump instruction APP 11-13 and APP 16-22 www.ro-solutions.com Table of Contents 1. Identification...2 2. System design...3 2.1 Open-ended systems with direct

More information

APP pump instruction APP 21-43

APP pump instruction APP 21-43 MAKING MODERN LIVING POSSIBLE Instruction APP pump instruction APP 21-43 ro-solutions.com Table of Contents 1. Identification...2 2. System design...3 2.1 Open-ended systems with direct water supply....3

More information

APP S pumps APP S / APP S / APP S 21-38

APP S pumps APP S / APP S / APP S 21-38 MAKING MODERN LIVING POSSIBLE Instruction APP S 2.0-3.5 / APP S 5.1-9.0 / APP S 21-38 ro-solutions.com Instruction Table of Contents 1. Identification...2 2. System design...3 2.1 Open system design...3

More information

PAHT pumps / PAHT G pumps / ATEX PAHT G pump

PAHT pumps / PAHT G pumps / ATEX PAHT G pump Lenntech info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 Data sheet PAHT 2-308 pumps / PAHT G 2-308 pumps / ATEX PAHT G pump danfoss.high-pressurepumps.com Table of Contents

More information

2/4/6.3, PAH 10/12.5, PAH 50/63/70/80/100 pumps

2/4/6.3, PAH 10/12.5, PAH 50/63/70/80/100 pumps Data sheet PAH pumps 2/4/6.3, PAH 10/12.5, PAH 2/4/6.3, PAH 10/12.5, PAH 20/25/32 and and PAH 50/63/70/80/100 PAH 50/63/70/80/100 pumps danfoss.high-pressurepumps.com hpp.danfoss.com Table of Contents

More information

PAHT pump PAHT X

PAHT pump PAHT X MAKING MODERN LIVING POSSIBLE Data sheet PAHT pump PAHT X 674 444 danfoss.high-pressurepumps.com Table of Contents 1. Introduction...3 2. Benefits...3 3. Application areas...3 4. Technical data...4 5.

More information

High-Pressure Pumps for Fire Fighting, type PAHF 20/25/32/40

High-Pressure Pumps for Fire Fighting, type PAHF 20/25/32/40 Data Sheet High-Pressure Pumps for Fire Fighting, type PAHF 20/25/32/40 with dedicated valves: relief valve (type VRHF), relief/bypass valve (type VPHF) and check valve (type VCH) Introduction The PAHF

More information

Nessie High-Pressure Pumps for technical water, type PAH

Nessie High-Pressure Pumps for technical water, type PAH Data Sheet Nessie High-Pressure Pumps for technical water, type PAH Generally The Danfoss Nessie high-pressure water pumps are especially designed for operation on technical water, such as reverse osmosis-,

More information

APP S 674 pumps APP S / APP S APP S

APP S 674 pumps APP S / APP S APP S MAKING MODERN LIVING POSSIBLE Data sheet APP S 674 3.0-3.5 / APP S 674 5.1-9.0 APP S 674 21-38 ro-solutions.com Table of Contents 1. Introduction...3 2. Benefits...3 3. Application areas...3 4. Technical

More information

APP pumps APP / APP / APP (W) / APP / APP / APP Lenntech. Data sheet

APP pumps APP / APP / APP (W) / APP / APP / APP Lenntech. Data sheet MAKING MODERN LIVING POSSIBLE Lenntech info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 Data sheet APP pumps APP 0.6-1.0 / APP 1.5-3.5 / APP (W) 5.1-10.2 / APP 11-13 / APP 16-22

More information

Data sheet APP

Data sheet APP MAKING MODERN LIVING POSSIBLE Data sheet Data sheet APP 0.6-1.0 ro-solutions.com Table of Contents 1. General information....2 2. Benefits...3 3. Technical data...3 4. Flow at different rpm....4 5. Flushing

More information

MAKING MODERN LIVING POSSIBLE. Data sheet. Data sheet APP ro-solutions.com

MAKING MODERN LIVING POSSIBLE. Data sheet. Data sheet APP ro-solutions.com MAKING MODERN LIVING POSSIBLE Data sheet Data sheet APP 11-13 ro-solutions.com Table of Contents 1. Introduction...3 2. Benefits...3 3. Technical data...4 4. Variants...4 5. Flow at different rpm....5

More information

Filter solutions for Danfoss PAH, APP and CLP pumps

Filter solutions for Danfoss PAH, APP and CLP pumps MAKING MODERN LIVING POSSIBLE Technical data sheet Lenntech info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 Filter solutions for Danfoss PAH, APP and CLP pumps 521B1009 / dkcfn.pd.090.a4.02

More information

MAKING MODERN LIVING POSSIBLE. Data sheet. Data sheet APP ro-solutions.com

MAKING MODERN LIVING POSSIBLE. Data sheet. Data sheet APP ro-solutions.com MAKING MODERN LIVING POSSIBLE ro-solutions.com Table of Contents 1. General information..................................................................... Benefits................................................................................

More information

Tel: +44 (0) E mail: Web: Data sheet. APP pumps APP ro-solutions.com

Tel: +44 (0) E mail: Web:   Data sheet. APP pumps APP ro-solutions.com APP pumps APP 53-78 Tel: +44 (0) 1706 869777 E mail: sales@desal.co.uk Web: www.desal.co.uk ro-solutions.com Table of Contents 1. Introduction...3 2. Benefits...3 3. Application examples...3 4 Technical

More information

The pumps are fixed displacement pumps in which the flow is proportional to the number of revolutions of the input shaft and the pump displacement.

The pumps are fixed displacement pumps in which the flow is proportional to the number of revolutions of the input shaft and the pump displacement. Lenntech DATA SHEET Water Pumps APP0.6 1.0 Compact 1. General information APP 0.6-1.0 pumps are designed to supply low viscosity and corrosive fluids under high pressure, eg. in seawater reverse osmosis

More information

Changing pistons APP and APP 16-22

Changing pistons APP and APP 16-22 MAKING MODERN LIVING POSSIBLE Instruction Changing pistons APP 11-13 and APP 16-22 ro-solutions.com Contents 1. Disassembling...3 2. Assembling...5 3. When should the pistons be replaced?....7 This document

More information

APP pumps APP / APP / APP / APP (W) / APP / APP / APP 21-43

APP pumps APP / APP / APP / APP (W) / APP / APP / APP 21-43 Data sheet Data sheet APP Pumps APP 0.6-1.0 / APP 1.5-3.5 / APP (W) 5.1-10.2 / APP 11-13 / APP pumps APP 16-22 0.6-1.0 / APP / 21-43 APP 1.5-3.5 / APP (W) 5.1-10.2 / APP 11-13 / APP 16-22 / APP 21-43 ro-solutions.com.

More information

ATEX instruction for APP / PAH PAHT G 2-90 / PAH Tech

ATEX instruction for APP / PAH PAHT G 2-90 / PAH Tech MAKING MODERN LIVING POSSIBLE Instruction ATEX instruction for APP 0.6-10.2 / PAH 2-100 PAHT G 2-90 / PAH 25-80 Tech danfoss.high-pressurepumps.com Table of Contents 1. Common demands for Category 2 and

More information

Disassembling and assembling PAH , PAHT and PAHT G

Disassembling and assembling PAH , PAHT and PAHT G MAKING MODERN LIVING POSSIBLE Instruction Disassembling and assembling PAH 10-12.5, PAHT 10-12.5 and PAHT G 10-12.5 danfoss.high-pressurepumps.com Table of Contents 1. Disassembling...3 2. Inspection...7

More information

Changing pistons APP 21-43

Changing pistons APP 21-43 MAKING MODERN LIVING POSSIBLE Instruction Changing pistons APP 21-43 ro-solutions.com Contents 1. Disassembling...3 2. Assembling...6 3. When should the pistons be replaced....8 4. Parts list for APP 21-38....9

More information

ATEX instruction APP S 674 pumps APP S , APP S and APP S

ATEX instruction APP S 674 pumps APP S , APP S and APP S MAKING MODERN LIVING POSSIBLE Instruction APP S 674 2.0-3.5, APP S 674 5.1-9.0 and APP S 674 21-38 ro-solutions.com Table of Contents 1. General information....2 2. Common demands for Category 2 and 3

More information

521B0850 DKCFN.PD.013.FA5.02

521B0850 DKCFN.PD.013.FA5.02 DATA SHEET Water Pumps APP0.6-3.5 1. General information APP0.6, APP1.0, APP1.5, APP1.8, APP2.2, APP2.5, APP3.0 and APP3.5 pumps are designed to supply low viscosity and corrosive fluids under high pressure,

More information

3/2-Way Zone-Drain-Valves VDHT 2E, VDHT 15E and VDHT 15EC

3/2-Way Zone-Drain-Valves VDHT 2E, VDHT 15E and VDHT 15EC Lenntech info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 3/2-Way Zone-Drain-Valves VDHT 2E, VDHT 15E and VDHT 15EC danfoss.high-pressurepumps.com General information The 3/2

More information

The electric motors are designed for driving equipment that requires continuous operation, and their high efficiency reduces energy consumption.

The electric motors are designed for driving equipment that requires continuous operation, and their high efficiency reduces energy consumption. DATA SHEET Sea Water Pump with Energy Recovery SWPE 1. General information The SWPE energy recovery unit consists of an APP pump and an motor, both connected to a double shafted electric motor. Energy

More information

Energy Recovery Device isave 21-40

Energy Recovery Device isave 21-40 MAKING MODERN LIVING POSSIBLE Data sheet Energy Recovery Device isave 21-40 www.isave.danfoss.com Table of Contents 1. General information....3 2. Benefits...3 3. Technical data...4 3.1 isave without motor...4

More information

INSTRUCTIONS Servicing PAH

INSTRUCTIONS Servicing PAH INSTRUCTIONS Servicing PAH 10-12.5 180R9095 Note: Dismantling: If the pump is dismantled during the warranty period, the pump is no longer under warranty. 180R9095 1. Tools required for dismantling the

More information

521B0851 DKCFN.PD.010.FB1.02

521B0851 DKCFN.PD.010.FB1.02 DATA SHEET Water Pumps APP5.1-10.2 1. General information APP5.1, APP6.5, APP7.2, APP8.2 and APP10.2 pumps are designed to supply low viscosity and corrosive fluids under high pressure, eg. in seawater

More information

521B0850 DKCFN.PD.010.FA2.02

521B0850 DKCFN.PD.010.FA2.02 DATA SHEET Water Pumps APP0.6-2.5 1. General information APP0.6, APP1.0, APP1.5, APP1.8, APP2.2 and APP2.5 pumps are designed to supply low viscosity and corrosive fluids under high pressure, eg. in seawater

More information

Water pumps for Desalination APP 16-22

Water pumps for Desalination APP 16-22 Data sheet Water pumps for Desalination APP 16-22 ro-solutions.com APP16-22 pumps are designed to supply low viscosity and corrosive fluids under high pressure, eg. in seawater reverse osmosis filtration

More information

Data sheet. Data sheet. APP pumps APP APP Pumps APP 53 / APP 65 / APP 78 / APP 86. ro-solutions.com

Data sheet. Data sheet. APP pumps APP APP Pumps APP 53 / APP 65 / APP 78 / APP 86. ro-solutions.com Data sheet Data sheet APP Pumps APP 53 / APP 65 / APP 78 / APP 86 APP pumps APP 53-86 ro-solutions.com Table of Contents 1. Introduction...3 2. Benefits...3 3. Application examples...3 4 Technical data...4

More information

Data sheet. Data sheet. APP pumps APP APP Pumps APP 53 / APP 65 / APP 78 / APP 86. ro-solutions.com. hpp.danfoss.com

Data sheet. Data sheet. APP pumps APP APP Pumps APP 53 / APP 65 / APP 78 / APP 86. ro-solutions.com. hpp.danfoss.com Data sheet Data sheet APP Pumps APP 53 / APP 65 / APP 78 / APP 86 APP pumps APP 53-86 ro-solutions.com hpp.danfoss.com Table of Contents 1. Introduction...3 2. Benefits...3 3. Application examples...3

More information

Energy Recovery Device isave 21-40

Energy Recovery Device isave 21-40 Data sheet Energy Recovery Device isave 21-40 www.isave.danfoss.com 521b1116 / dkcfn.pd.003.a2.02 1. General information The isave 21-40 consists of an isobaric pressure exchanger (PE), a high pressure

More information

E 068 E 088 In-line mounting Connection up to G¾ Nominal flow rate up to 100 l/min

E 068 E 088 In-line mounting Connection up to G¾ Nominal flow rate up to 100 l/min Return-Suction Filters E 68 E 88 In-line mounting Connection up to G¾ Nominal flow rate up to l/min Description Application For operation in units with hydrostatic drives, when the return flow is under

More information

Starting up hydraulic systems

Starting up hydraulic systems General / Installation A hydraulic system that operates economically, safely, and trouble-free requires careful planning, as well as proper installation and start-up. Conscientious maintenance has a considerable

More information

Solenoid valve VDHT Standard BSP (British Standard Pipe)

Solenoid valve VDHT Standard BSP (British Standard Pipe) MAKING MODERN LIVING POSSIBLE Data sheet Standard BSP (British Standard Pipe) high-pressurepumps.danfoss.com Contents 1. Picture overview...3 2. Introduction...4 3. VDHT valve selection overview...4 4.

More information

Parallel coupled APP pumps

Parallel coupled APP pumps Design Guide Parallel coupled APP pumps Parallel coupled APP pumps and energy energy recovery devices recovery devices hpp.danfoss.com Table of Contents Table of Contents 1. Introduction...3 2. Preferred

More information

Return-Suction Filters E 068 E 088. In-line mounting Connection up to G¾ Nominal flow rate up to 100 l/min e

Return-Suction Filters E 068 E 088. In-line mounting Connection up to G¾ Nominal flow rate up to 100 l/min e Return-Suction Filters E 68 E 88 In-line mounting Connection up to G¾ Nominal flow rate up to l/min.8-e Description Application For operation in units with hydrostatic drives, when the return flow is under

More information

Oil pump type RSA. Catalogue 1. Burner Components

Oil pump type RSA. Catalogue 1. Burner Components Burner Components Catalogue 1 Contents Application... page 2 Construction... page 3 Function... page 4 Technical data... page 6 Capacity and operating torque RSA 28... page 7 Capacity and operating torque

More information

Series TMM Axial Piston Motor. Technical Information

Series TMM Axial Piston Motor. Technical Information Series TMM Axial Piston Motor Technical Information General Description GENERAL DESCRIPTION These motors are designed primarily to be combined with other products in closed circuit systems to transfer

More information

Pre-Fabricated Flushing Bypass Assembly for Plant Applications Hero Plant DN15-150

Pre-Fabricated Flushing Bypass Assembly for Plant Applications Hero Plant DN15-150 Pre-Fabricated Flushing Bypass Assembly for Plant Applications Description Hero Plant is a pre-fabricated, flushing bypass arrangement for balance, control, isolation, and operation of plant devices. Flow

More information

ELIMINATOR Hermetic filter drier Types DCL and DML

ELIMINATOR Hermetic filter drier Types DCL and DML Data sheet ELIMINATOR Hermetic filter drier s DCL and DML All ELIMINATOR driers have a solid core with binding material held to an absolute minimum. There are two types of ELIMINATOR cores. DML driers

More information

MAKING MODERN LIVING POSSIBLE. Product overview. . Energy efficient. Reliable. Very long service intervals HIGH-PRESSURE SYSTEMS

MAKING MODERN LIVING POSSIBLE. Product overview. . Energy efficient. Reliable. Very long service intervals HIGH-PRESSURE SYSTEMS MAKING MODERN LIVING POSSIBLE Product overview. Energy efficient. Reliable. Very long service intervals HIGH-PRESSURE SYSTEMS Application examples: Fire fighting: Using high-pressure water mist for fire

More information

PAHT / PAHT G pumps PAHT / PAHT G Disassembling and assembling

PAHT / PAHT G pumps PAHT / PAHT G Disassembling and assembling Service guide PAHT / PAHT G pumps PAHT 256-308 / PAHT G 256-308 Disassembling and assembling hpp.danfoss.com Table of Contents 1. Introduction... 2 2. Disassembling the pump... 3 3. Assembling the pump...

More information

Series 20 Axial Piston Pumps. Technical Information

Series 20 Axial Piston Pumps. Technical Information Series 20 Axial Piston Pumps Technical Information General Description INTRODUCTION Sauer-Danfoss a world leader in hydraulic power systems has developed a family of axial piston pumps. DESCRIPTION Sauer-Danfoss

More information

THRU DRIVE HYDRAULIC VANE PUMP TQ/TV SERIES

THRU DRIVE HYDRAULIC VANE PUMP TQ/TV SERIES THRU DRIVE HYDRAULIC VANE PUMP TQ/TV SERIES TQ/TV THRU-DRIVE HYDRAULIC VANE PUMPS TQ/TV SERIES Thru-drive pumps save installation space and cost by eliminating double shaft extension electric motors or

More information

Series 20 Axial Piston Pumps. Technical Information

Series 20 Axial Piston Pumps. Technical Information Series 20 Axial Piston Pumps Technical Information General Description INTRODUCTION Sauer-Danfoss a world leader in hydraulic power systems has developed a family of axial piston pumps. DESCRIPTION Sauer-Danfoss

More information

FNA 008 FNA 016 Operating pressure up to 4 bar / 58 psi Nominal flow rate up to 16 l/min / 4.2 gpm

FNA 008 FNA 016 Operating pressure up to 4 bar / 58 psi Nominal flow rate up to 16 l/min / 4.2 gpm Off-line Filter Units FNA 008 FNA 016 Operating pressure up to 4 bar / 58 psi Nominal flow rate up to 16 l/min / 4.2 gpm Description Application In the by-pass flow of hydraulic and lubrication systems.

More information

Low Speed High Torque Motors

Low Speed High Torque Motors Low Speed High Torque Motors Catalogue HY29-0503/UK TABLE OF CONTENTS Table of contents Features General information Functional description Technical data 3 4 4 5 6 FRAME SIZE P Operating diagrams Overall

More information

TPV Variable Displacement Closed Loop System Axial Piston Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 852 / 0815 / E

TPV Variable Displacement Closed Loop System Axial Piston Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 852 / 0815 / E HYDRAULIC COMPONENTS HYDROSTATIC TRANSMISSIONS GEARBOXES - ACCESSORIES Certified Company ISO 9001-14001 ISO 9001 Via M. L. King, 6-41122 MODENA (ITALY) Tel: +39 059 415 711 Fax: +39 059 415 729 / 059 415

More information

SonoSelect and SonoSafe energy meters

SonoSelect and SonoSafe energy meters energy meters 03/2017 Danfoss VUIGB602 www.heating.danfoss.com 1 Note! To ensure latest version of declaration, please visit danfoss.com. 2 Danfoss Energy Meters 2017.03 VUIGB702 Contents 1. Inside the

More information

Installation and commissioning of Settima screw pumps. Type GR** SMT** 3-screw screw pumps. a. Medium:

Installation and commissioning of Settima screw pumps. Type GR** SMT** 3-screw screw pumps. a. Medium: Settima screw a. Medium: HL oil conforming to DIN 51524 Parts 2 and 3 Special media such as: HFA min 5% oil HFB min 40% oil HFC max. 35-55% water HFDR high-viscosity lubricants SKYDROL, MIL-H may also

More information

ELIMINATOR Hermetic filter drier Types DML and DCL

ELIMINATOR Hermetic filter drier Types DML and DCL Data sheet ELIMINATOR Hermetic filter drier s DML and DCL All ELIMINATOR driers have a solid core with binding material held to an absolute minimum. There are two types of ELIMINATOR cores. DML driers

More information

Return-Suction Filters E 158 E 198 E 248. Tank top mounting Connection up to -20 SAE Nominal flow rate up to 66 gpm us

Return-Suction Filters E 158 E 198 E 248. Tank top mounting Connection up to -20 SAE Nominal flow rate up to 66 gpm us Return-Suction Filters E 58 E 98 E 48 Tank top mounting Connection up to - SAE Nominal flow rate up to gpm.9-7us Description Application For operation in units with hydrostatic drives, when the return

More information

TPV Variable Displacement Closed Loop System Axial Piston Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 851 / 0813 / E

TPV Variable Displacement Closed Loop System Axial Piston Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 851 / 0813 / E HYDRAULIC COMPONENTS HYDROSTATIC TRANSMISSIONS GEARBOXES - ACCESSORIES THE PRODUCTION LINE OF HANSA-TMP Variable Displacement Closed Loop System CONTENTS General Information... Order Code... Manual Control

More information

ON/OFF zone valves AMZ 112, AMZ 113

ON/OFF zone valves AMZ 112, AMZ 113 Data sheet ON/OFF zone valves AMZ 112, AMZ 113 Description The ON/OFF zone valves type AMZ 112 and AMZ 113 are typical used in connection with: Domestic and commercial central heating applications Domestic

More information

We produce fluid power solutions. Fluid Management. Off-line Filters Off-line Filter Units Oil Service Units Dewatering Systems Filter Elements

We produce fluid power solutions. Fluid Management. Off-line Filters Off-line Filter Units Oil Service Units Dewatering Systems Filter Elements We produce fluid power solutions Fluid Management Off-line Filters Off-line Filter Units Oil Service Units Dewatering Systems Filter Elements Products with these icons are specially made for: Industrial

More information

FN 060 FN 300 In-line mounting Operating pressure up to 12 bar / 174 psi Nominal flow rate up to 650 l/min / 172 gpm

FN 060 FN 300 In-line mounting Operating pressure up to 12 bar / 174 psi Nominal flow rate up to 650 l/min / 172 gpm Off-line Filters FN 6 FN In-line mounting Operating pressure up to bar / 74 psi Nominal flow rate up to 65 l/min / 7 gpm Description Application Return-flow filter or off-line filter in hydraulic and lubrication

More information

Reliable season change

Reliable season change New perspectives with Danfoss Saginomiya 4 - Way Reversing Valves Reliable season change, VHV 4-way reversing valves Wide application range - complete capacity range - available for all common refrigerants

More information

PVG 120 Proportional Valves. Service Parts Manual

PVG 120 Proportional Valves. Service Parts Manual PVG 120 Proportional Valves Service Parts Manual Contents and Data Survey CONTENTS AND DATA SURVEY Page Sectional drawing... 3 Identification...4 Installation PVG... 5 Spare parts... 22 Pos. 1: PVP, pump

More information

TROUBLESHOOTING TABLE

TROUBLESHOOTING TABLE TROUBLESHOOTING TABLE TROUBLESHOOTING GUIDE GLOSARY OF TERMS VANE PUMPS NO FLOW, NO PRESSURE A) Is the pump rotating? a-1) Check if the coupling is rotating. If not, check the rotation of the electric

More information

Spin-on filter according to Bosch Rexroth standard: Type 50 SL 30 to 80D. Features. Contents. RE Edition:

Spin-on filter according to Bosch Rexroth standard: Type 50 SL 30 to 80D. Features. Contents. RE Edition: Spin-on filter according to Bosch Rexroth standard: Type 50 SL 30 to 80D RE 51476 Edition: 2015-06 Nominal sizes: 30 to 80D Connection up to G1; SAE 10 56558_d Features Spin-on filters are used in hydraulic

More information

Backflushing Filter AutoFilt RF3

Backflushing Filter AutoFilt RF3 Backflushing Filter AutoFilt C 2,5 4 6 8 1. TECHNICAL SPECIFICATIONS 1.1 GENERAL The automatic back-flushing filter AutoFilt is a self-cleaning system for extracting particles from lowviscosity fluids.

More information

Directional Control Valve

Directional Control Valve Directional Control Valve Service and Parts Manual powersolutions.danfoss.com Directional Control Valves Service and Parts Manual: Contents SERVICE PARTS Inlet cover... 3-4 Outlet cover... 5-6 Standard

More information

Butterfly valve with electrical actuator VFY-WA

Butterfly valve with electrical actuator VFY-WA Butterfly valve with electrical actuator Description Position indicator Torque limiter Complete installation from factory - ready for installation Features: Spline driven one piece shaft connected to spherically

More information

Butterfly valve with electrical actuator VFY-WA

Butterfly valve with electrical actuator VFY-WA Butterfly valve with electrical actuator Description Position indicator Torque limiter Complete installation from factory - ready for installation Features: Spline driven one piece shaft connected to spherically

More information

Floor heating system, heating circuit with FHV-A in flow.

Floor heating system, heating circuit with FHV-A in flow. Application FHV control valves are ideally suited for controlling the temperature of individual under-floor heated rooms and for systems using floor-heating in conjunction with radiators. Danfoss offers

More information

ELIMINATOR Hermetic bi-flow filter drier Types DMB and DCB

ELIMINATOR Hermetic bi-flow filter drier Types DMB and DCB Data sheet ELIMINATOR Hermetic bi-flow filter drier s DMB and DCB Hermetic bi-flow filter driers, types DMB and DCB are for use in liquid lines on heat pumps. Hermetic bi-flow filter driers have built-in

More information

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Contents Section 1. General Observations... 2 2. Operation... 4 3. Control During Operation... 5 4. Trouble Shooting... 6 5. Maintenance... 7 Please

More information

IGP /117 ED INTERNAL GEAR PUMPS SERIES 10 OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS HYDRAULIC SYMBOL

IGP /117 ED INTERNAL GEAR PUMPS SERIES 10 OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS HYDRAULIC SYMBOL 00/7 ED IGP INTERNAL GEAR PUMPS OPERATING PRINCIPLE IGP pumps are volumetric displacement pumps with internal gears, available in five sizes, each divided into a range of different displacement. The pumps

More information

RA / Internal Gear Pump Model GP3, Series 3X Fixed Displacement. Typical application:

RA / Internal Gear Pump Model GP3, Series 3X Fixed Displacement. Typical application: Sizes 20 to 32 Internal Gear Pump Model GP3, Series 3X Fixed Displacement up to 5076 PSI 1.25 to 1.98 in 3 (350 bar) (20.6 to 32.5 cm 3 ) RA 10 234/07.97 Characteristics: Peak pressure of up to 5.076 PSI

More information

anus Pumps - Axial Piston V FM 87247

anus Pumps - Axial Piston V FM 87247 anus Pumps - Axial Piston anus Pumps - Axial Piston Our anus Axial Piston Pumps are totally oil free, clean and completely safe to use. As a result of employing advanced materials, high velocity and loaded

More information

Anti-lock Brake System (ABS),

Anti-lock Brake System (ABS), Page 1 of 12 45-6 Anti-lock Brake System (ABS), Bosch 5.0 CAUTION! The anti-lock brake system is basically maintenance-free. Specialist knowledge is required for performing any work on this system. Failure

More information

Operating Guide SBFV (PN16/25) ENGLISH Steel butterfly valve SBFV Page 2. Danfoss VI.IX.A1.02 1

Operating Guide SBFV (PN16/25) ENGLISH Steel butterfly valve SBFV   Page 2. Danfoss VI.IX.A1.02 1 Operating Guide SBFV (PN16/25) ENGLISH Steel butterfly valve SBFV www.danfoss.com Page 2 Danfoss 2016.06 VI.IX.A1.02 1 Table of Contents: 1. OVERVIEW... 3 2. GENERAL... 3 2.1 Safety...3 2.2 Proper use...4

More information

OML and OMM Orbital motors. Technical Information

OML and OMM Orbital motors. Technical Information OML and OMM Orbital motors Technical Information OML and OMM A wide range of orbital motors F300030.TIF A WIDE RANGE OF ORBITAL MOTORS Sauer-Danfoss is a world leader within production of low speed orbital

More information

Quality Products for Mechanical & Fluid Power. TQ & TV Series VANE PUMPS

Quality Products for Mechanical & Fluid Power. TQ & TV Series VANE PUMPS 1 Quality Products for Mechanical & Fluid Power 1 TQ & TV Series VANE PUMPS TQ/TV THRU-DRIVE HYDRAULIC VANE PUMPS TQ/TV SERIES Thru-drive pumps save installation space and cost by eliminating double shaft

More information

SonoSensor 30 Ultrasonic flow meter for heating and cooling applications

SonoSensor 30 Ultrasonic flow meter for heating and cooling applications Installation & User Guide SonoSensor 30 Ultrasonic flow meter for heating and cooling applications 03/2017 Danfoss VDIGK202 www.heating.danfoss.com 1 Note! To ensure latest version of declaration, please

More information

MOTORS MV HYDRAULIC MOTORS T E C H N I C A L C A T A L O G

MOTORS MV HYDRAULIC MOTORS T E C H N I C A L C A T A L O G OTORS V HYDRAULIC OTORS T E C H N I C A L C A T A L O G otors V - Hydraulic otors POCLAIN HYDRAULICS OVERVIEW Displacement Speed V2 V3 aximum cm³/rev [in³/rev.] From 3 [2.14] to 3 [3.23] From [3.3] to

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS SERIE BV

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS SERIE BV FIXED DISPLACEMENT HYDRAULIC VANE PUMPS SERIE BV BV FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BV SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps.

More information

Assisted lift operated 2/2-way solenoid valves Type EV251B

Assisted lift operated 2/2-way solenoid valves Type EV251B Data sheet Assisted lift operated 2/2-way solenoid valves Type EV251B EV251B with assisted lift is especially suitable for applications such as closed systems with low and fluctuating pressure conditions

More information

OSPB, OSPC, OSPR, OSPD Open Center Steering units OSPB Closed Center Steering units TAD Torque amplifiers. Technical Information

OSPB, OSPC, OSPR, OSPD Open Center Steering units OSPB Closed Center Steering units TAD Torque amplifiers. Technical Information OSPB, OSPC, OSPR, OSPD Open Center Steering units OSPB Closed Center Steering units TAD Torque amplifiers Technical Information A wide range of steering components A WIDE RANGE OF STEERING COMPONENTS F300599

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BV SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BV SERIES BV FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BV SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

Crankcase pressure regulator Type KVL

Crankcase pressure regulator Type KVL Data sheet Crankcase KVL KVL crankcase are used to protect the compressor motor against overload experienced during startup after long off periods or just after defrost periods. They are installed in the

More information

Filter solutions for Danfoss PAH, APP and CLP pumps

Filter solutions for Danfoss PAH, APP and CLP pumps Data Sheet Filter solutions for Danfoss PAH, APP and CLP pumps Introduction To ensure optimum pump life, it is important that the incoming fluid is filtered properly. It is recommended to use filters from

More information

Integrated Valve with Presetting for Manifolds in Two-Pipe Heating Systems

Integrated Valve with Presetting for Manifolds in Two-Pipe Heating Systems Data Sheet Integrated Valve with Presetting for Manifolds in Two-Pipe Heating Systems The integrated valve is designed for manifold applications in combination with a system connection piece. Valve and

More information

The Water Hydraulics Co. Ltd.

The Water Hydraulics Co. Ltd. Body text 3/2 Valve Spring to Open P V03.16 Our Janus axial piston motors are totally oil free, clean and completely safe to use. As a result of employing advanced materials, high velocity and loaded sliding

More information

LS 025 LS 035 In-line mounting Connection up to G¾ / -12 SAE Nominal flow rate up to 33 l/min / 8.7 gpm

LS 025 LS 035 In-line mounting Connection up to G¾ / -12 SAE Nominal flow rate up to 33 l/min / 8.7 gpm Suction Filters LS 025 LS 035 In-line mounting Connection up to G¾ / -2 SAE Nominal flow rate up to 33 l/min / 8.7 gpm Description Application To be installed in the suction line of the pumps of hydraulic

More information

Flow-compensated temperature controller AVTQ DN 15

Flow-compensated temperature controller AVTQ DN 15 Data sheet Flow-compensated temperature controller AVTQ DN 15 Description AVTQ is a self-acting flow-compensated temperature controller primarily for use in district heating systems with plate heat exchangers

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS SERIE BQ

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS SERIE BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS SERIE BQ BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps.

More information

RA / Internal Gear Pump Model GP2, Series 2X Fixed Displacement. Typical application:

RA / Internal Gear Pump Model GP2, Series 2X Fixed Displacement. Typical application: Sizes 6.3 to 16 Internal Gear Pump Model GP2, Series 2X Fixed Displacement up to 576 PSI.397 to.98 in 3 (35 bar) (6.5 to 16 cm 3 ) RA 1 23/6.97 RA 1 23/6.97 Characteristics: Peak pressure of up to 576

More information

OMEW Standard and with Low Speed Option. Orbital Motors. Technical Information

OMEW Standard and with Low Speed Option. Orbital Motors. Technical Information Standard and with Low Speed Option Orbital Motors Technical Information Contents Revision History Table of Revisions Date Page Changed Rev Jan 2009 Many major change BA Mar 2010 16 Japan location BB Contents

More information

Nessie 3/2-Way Zone-Drain-Valves types VDM 2E, VDHT 15E, VDHT 15EC and VDH 30EC "Soft-Charge"

Nessie 3/2-Way Zone-Drain-Valves types VDM 2E, VDHT 15E, VDHT 15EC and VDH 30EC Soft-Charge Nessie 3/2-Way Zone-Drain-Valves types VDM 2E, VDHT 15E, VDHT 15EC and VDH 30EC "Soft-Charge" Generally The Nessie 3/2 way valves have in particular been designed for applications in high-pressure humidification

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS SERIE BQ

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS SERIE BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS SERIE BQ BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps.

More information

Pressure Relief Valve DB12 CE

Pressure Relief Valve DB12 CE Pressure Relief Valve DB12 CE up to 120 l/min Connection housings 1. DESCRIPTION 1.1. GENERAL According to DIN-ISO 1219, HYDAC pressure relief valves DB12-CE are valves for oil hydraulic systems to control

More information

Variable Displacement Pump A4VG for closed circuits

Variable Displacement Pump A4VG for closed circuits RE 92 003/05.99 RE 92 003/05.99 replaces: 02.98 Variable Displacement Pump A4VG for closed circuits Sizes 28...250 Series 3 Nominal pressure 400 bar Peak pressure 450 bar A4VG...EP Index Features 1 Ordering

More information

Vane Pumps. VMQ Series Vane Pumps For Industrial and Mobile Applications Displacements to 215 cm 3/ r (13.12 in 3 /r) Pressures to 260 bar (3800 psi)

Vane Pumps. VMQ Series Vane Pumps For Industrial and Mobile Applications Displacements to 215 cm 3/ r (13.12 in 3 /r) Pressures to 260 bar (3800 psi) Vickers Vane Pumps VMQ Series Vane Pumps For Industrial and Mobile Applications Displacements to 215 cm 3/ r (13.12 in 3 /r) Pressures to 260 bar (3800 psi) 5008.00/EN/0596/A A.25 Introduction From the

More information

RV1P /118 ED VARIABLE DISPLACEMENT VANE PUMPS SERIES 10 OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS HYDRAULIC SYMBOL

RV1P /118 ED VARIABLE DISPLACEMENT VANE PUMPS SERIES 10 OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS HYDRAULIC SYMBOL 14 201/118 ED RV1P VARIABLE DISPLACEMENT VANE PUMPS OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS (measured with mineral oil with viscosity of 46 cst at 40 C) RV1P are variable displacement vane pumps with

More information

ES 134 ES 144 Tank top mounting Connection up to SAE 1½ Nominal flow rate up to 130 l/min

ES 134 ES 144 Tank top mounting Connection up to SAE 1½ Nominal flow rate up to 130 l/min Suction Filters ES 134 ES 144 Tank top mounting Connection up to SAE 1½ Nominal flow rate up to 130 l/min Description Application To be installed in the suction line of the pumps of hydraulic systems resp.

More information

PV Series E, J, & L Piston Pump Installation Tips and Procedures

PV Series E, J, & L Piston Pump Installation Tips and Procedures Sept. 9, 2005 PV Series E, J, & L Piston Pump Installation Tips and Procedures Oil recommendations Do not use automatic transmission fluid (ATF), bio-degradable oil, or fire resistant fluids due to the

More information

FNA 045 Operating pressure up to 7 bar / 101 psi Nominal flow rate up to 45 l/min / 12 gpm

FNA 045 Operating pressure up to 7 bar / 101 psi Nominal flow rate up to 45 l/min / 12 gpm Off-line Filter Unit FNA 045 Operating pressure up to 7 bar / 101 psi Nominal flow rate up to 45 l/min / 12 gpm Description Application In the by-pass flow of hydraulic and lubrication systems. Performance

More information