ELIMINATOR Hermetic filter drier Types DML and DCL
|
|
- Abigail Brooks
- 6 years ago
- Views:
Transcription
1 Data sheet ELIMINATOR Hermetic filter drier s DML and DCL All ELIMINATOR driers have a solid core with binding material held to an absolute minimum. There are two types of ELIMINATOR cores. DML driers have a core composition of 100% Molecular Sieve, while type DCL contain 80% Molecular Sieve with 20% activated alumina. ELIMINATOR type DML driers are designed for applications requiring the highest moisture capacity. ELIMINATOR type DCL driers are designed for applications requiring high moisture capacity and acid adsorption capacity. Available with solder (cu-plated steel connectors) and flare connections. For other connections please contact your Danfoss Sales Representative. Features The Core type DML 100% Molecular Sieve core High drying capacity minimizing the risk of acid formation (hydrolysis) Recommended for use with HFC and HCFC refrigerants Will not deplete oil additives The Core type DCL 80% Molecular Sieve with 20% activated alumina Perfect core blend for systems that operate at high condensing temperatures and require high drying capacity Recommended for use with HFC and HCFC refrigerants The Shell PED approved for PS 46 bar Available with solder (Cu-plated steel connectors) and flare connections Corrosion resistant powder-painted finish. Special coating for marine applications available upon request Allows installation with any orientation provided the arrow is in the flow direction Available in sizes 3 75 cubic inches The Filter 25 μm (0.001 in.) filter provides high retention with minimal pressure drop Thermally stable up to 120 C Danfoss DCS (az) DKRCC.PD.EB0.C H
2 Approvals UL US, file no. SA 6398 PED 97/23/EC - a3p3 Compliant with ATEX hazard zone 2 Note: Only solder versions (cu-plated / pure copper) and connection sizes below 25 mm are approved for flammable refrigerants now. Introduction ELIMINATOR Hermetic filter driers protect refrigeration and air-conditioning systems from moisture, acids, and solid particles. With these contaminants eliminated, systems are safer from harmful chemical reactions and from abrasive impurities. Danfoss R EVR AKS EKC TCAE SGN GBC DML / DCL GBC Technical data Flare connection Surface and volume Filter drier volume (shell volume) Filter drier volume (net volume) Filter Solid core surface Solid core volume [cm 2 ] [cm 2 ] [l] [l] DML/DCL DML/DCL DML/DCL DML/DCL DML/DCL DML/DCL DML/DCL DML/DCL Solder connection (cu-plated steel connectors) Filter Acid capacity 1 ) [g] DCL DCL DCL DCL DCL DCL DCL DCL ) Adsorption capacity of oleic acid at 0.05 TAN (Total Acid Number). Temperature range: C Maximum working pressure: PS 46 bar Danfoss DCS (az) DKRCC.PD.EB0.C H
3 Technical data and capacities Drying and liquid capacity, type DML Drying capacity [kg] refrigerant 1 ) Liquid capacity [kw] 2 ) R134a R404A R507 R22 R407C R410A R32 [ C] R134a R404A R507 R22 R407C R410A R DML 032/032s DML 032.5s DML 033/033s DML 034s DML 052/052s DML 052.5s DML 053/053s DML 054s DML 055s DML 082/082s DML 082.5s DML 083/083s DML 084/084s DML 085/085s DML 162/162s DML 162.5s DML 163/163s DML 164/164s DML 165/165s DML 166/166s DML 167s DML 303/303s DML 304/304s DML 305/305s DML 306/306s DML 307s DML 309s DML DML 414/414s DML 415/415s DML 417s DML 419s DML 604s DML 607s DML 609s DML 757s DML 759s ) Drying capacity is based on following moisture content test standards before and after drying: R32: ppm W R134a: ppm W R404A, R507: ppm W R407C: ppm W R410A: ppm W R22: ppm W In accordance with ARI ) Given in accordance with ARI for t e= -15 C t c= 30 C Δp = 0.07 bar For technical data on other refrigerants, please contact your Danfoss Sales Representative Danfoss DCS (az) DKRCC.PD.EB0.C H
4 Technical data and capacities (continued) Drying and liquid capacity, type DCL Drying capacity [kg] refrigerant 1 ) Liquid capacity [kw] 2 ) R134a R404A R507 R22 R407C R410A R32 [ C] R134a R404A R507 R22 R407C R410A R32 DCL 032/032s DCL 032.5s DCL 033/033s DCL 052/052s DCL 052.5s DCL 053/053s DCL 082/082s DCL 082.5s DCL 083/083s DCL 084/084s DCL 162/162s DCL 162.5s DCL 163/163s DCL 164/164s DCL 165/165s DCL 166/166s DCL 167s DCL 303/303s DCL 304/304s DCL 305/305s DCL 306/306s DCL 307s DCL 309s DCL DCL 414/414s DCL 415/415s DCL 417s DCL 419s DCL 604s DCL 607s DCL 609s DCL 757s DCL 759s ) Drying capacity is based on following moisture content test standards before and after drying: R32: ppm W R134a: ppm W R404A, R507: ppm W R407C: ppm W R410A: ppm W R22: ppm W In accordance with ARI ) Given in accordance with ARI for t e= -15 C t c= 30 C Δp = 0.07 bar For technical data on other refrigerants, please contact your Danfoss Sales Representative Conversions Drops of water = (1 kg of refrigerant (Initial PPM of water - Final PPM of water)) 50 See ARI standard for recommended initial and final PPM values for different refrigerants. Danfoss DCS (az) DKRCC.PD.EB0.C H
5 Ordering DCL Flare Connection size Multi pack Industrial pack for OEM only [in.] [mm] Code no. Qty. Code no. Qty. DCL Z ) 32 DCL Z DCL Z ) 32 DCL Z DCL Z Z DCL Z Z DCL Z Z DCL Z Z DCL Z DCL Z Z DCL Z Z DCL Z Z DCL Z Z DCL Z DCL Z DCL Z Z DCL Z Z DCL Z DCL Z DCL Z ) Wire mesh in filter drier outlet Danfoss DCS (az) DKRCC.PD.EB0.C H
6 Ordering (continued) DML Flare Connection size Multi pack Industrial pack for OEM only [in.] [mm] Code no. Qty. Code no. Qty. DML Z ) Z ) 28 DML Z ) Z ) 28 DML Z DML Z Z DML Z Z DML Z Z DML Z Z DML Z Z DML Z DML Z Z DML Z Z DML Z Z DML Z Z DML Z DML Z Z DML Z Z DML Z Z DML Z Z DML Z DML Z DML Z DML Z Z DML Z Z ) Wire mesh in filter drier outlet Danfoss DCS (az) DKRCC.PD.EB0.C H
7 Ordering (continued) DCL Solder (cu-plated steel connectors) Conn. size Multi pack Industrial pack for OEM only Conn. size Multi pack Industrial pack for OEM only [in.] Code no. Qty. Code no. Qty. [mm] Code no. Qty. Code no. Qty. DCL 032s Z Z Z Z DCL 032.5s Z Z DCL 033s Z Z DCL 052s Z Z Z Z DCL 052s Z DCL 053s Z Z Z DCL 082s Z Z DCL 082s Z DCL 083s Z Z Z Z DCL 084s Z Z Z DCL 162s Z Z DCL 163s Z Z Z DCL 164s Z Z Z DCL 165s Z Z DCL 166s Z DCL 167s 7 /8 023Z DCL 303s Z Z Z DCL 304s Z Z DCL 305s Z Z DCL 306s Z Z DCL 307s Z Z DCL 309s Z Z DCL 414s Z DCL 415s Z DCL 417s Z DCL 419s Z Z DCL 604s Z DCL 607s Z DCL 609s Z DCL 757s Z DCL 759s Z Z Danfoss DCS (az) DKRCC.PD.EB0.C H
8 Ordering (continued) DML Solder (cu-plated steel connectors) Conn. size Multi pack Industrial pack for OEM only Conn. size Multi pack Industrial pack for OEM only [in.] Code no. Qty. Code no. Qty. [mm] Code no. Qty. Code no. Qty. DML 032s Z Z Z Z DML 032.5s Z Z DML 033s Z Z Z Z DML 034s 1 /2 023Z Z DML 052s Z Z Z Z DML 052.5s Z DML 053s Z Z Z Z DML 054s Z Z Z DML 055s Z Z DML 082s Z Z Z Z DML 082.5s Z DML 083s Z Z Z Z DML 084s Z Z Z Z DML 085s Z DML 162s Z Z DML 163s Z Z Z Z DML 164s Z Z Z Z DML 165s Z Z DML 166s Z Z DML 167s 7 /8 023Z DML 303s Z Z DML 304s Z Z Z Z DML 305s Z Z DML 306s Z Z DML 307s Z Z DML 309s Z Z DML 414s Z Z DML 415s Z DML 417s Z Z DML 419s Z Z Z DML 604s Z Z DML 605s Z DML 607s Z Z DML 609s Z Z DML 757s Z Z DML 759s Z Z Z Danfoss DCS (az) DKRCC.PD.EB0.C H
9 Identification codes Codes Description Filter drier D Drier Solid core Application L Liquid line Size (volume) Connection (filter connection in 1 8 of an inch increments) Connection type C M 03 3 in in in in in in in in in. 3 80% Molecular Sieve / 20% activated alumina 100% Molecular Sieve core in. / 6 mm in. / 8 mm in. / 10 mm in. / 12 mm in. / 16 mm in. / 18 (19) mm in. / 22 mm in. / 28 mm (blank) s Flare connection Solder connection Example for type codes D C L 05 3 s Filter drier Solid core Application Size (volume) Connection (filter connection in 1 8 of an inch increments) Connection type Danfoss DCS (az) DKRCC.PD.EB0.C H
10 Selection selection is made considering the application Refrigerant and oil types DCL DML HFO Recommended Recommended Refrigerant HC 1 ) Recommended Recommended HFC Recommended Recommended HCFC Recommended Recommended Mineral or AB Recommended Recommended Oil POE or PAG, pure Recommended Recommended POE or PAG, with additives Not recommended 2 ) Recommended 1 ) Only solder versions (cu-plated / pure copper) and connection sizes below 25 mm are approved for flammable refrigerants now. 2 ) DCL Hermetic filter driers contain activated alumina, which is a polar material used for acid adsorption. Many oil additives are also polar substances and can be adsorbed by the activated alumina, rendering them useless, and reducing the drier s acid capacity, though this is not harmful to the system. Selection example Select the appropriate type (DML or DCL) based on refrigerant and oil type. Then select the drier size based on the adsorption and liquid capacity required. a. Amount of charge: 25 kg R134a at tl= 24 C To dry 25 kg R134a at 24 C from 1050 to 60 ppm moisture, a DML 16 is necessary b. Cooling capacity: Qe= 20 kw To obtain a mass flow corresponding to 20 kw cooling capacity with a DML 16 filter drier, a 3 8 inch connection must be chosen. Larger connections can be chosen in accordance with the liquid line dimension c. Result DML 163 or DML 163s can be used If the initial moisture content is very small or a planned change of the filter drier is considered, a smaller filter drier size can be chosen. Drying capacity [kg] refrigerant 1 ) Liquid capacity [kw] 2 ) R134a R404A R507 R22 R407C R410A R32 [ C] R134a R404A R507 R22 R407C R410A R DML 1.52s DML 1.52x2/2s DCL 032.5s DCL 033/033s DML 163/163s DML 164/164s DML 165/165s DML 166/166s DML 167s DML 303/303s DCL 084/084s DCL 162/162s Danfoss DCS (az) DKRCC.PD.EB0.C H
11 Design / Function DML / DCL 03 DML / DCL 05 DML / DCL 08, DML / DCL 16 DML / DCL 30, DML / DCL 41 Danfoss 23Z DML / DCL 60, DML / DCL Inlet 2. Spring 3. Solid core 4. Polyester mat 5. Perforated plate 6. Seal cap, flare connection 7. Seal cap, solder connection The relatively large diameter of the hermetic filter drier means that the liquid flow velocity is suitably low and the pressure drop minimal. Powder formation is eliminated because the solid core grains are bonded and cannot move against each other. Danfoss DCS (az) DKRCC.PD.EB0.C H
12 Dimensions and weights Flare connections A A1 A2 L D1 D2 Net weight [mm] [mm] [mm] [mm] [mm] [mm] [Kg] DCL / DML DCL / DML A A1 A2 L D1 D2 Net weight [mm] [mm] [mm] [mm] [mm] [mm] [Kg] DCL / DML DCL / DML Danfoss DCS (az) DKRCC.PD.EB0.C H
13 Dimensions and weights (continued) Flare connections A A1 A2 L D1 D2 Net weight [mm] [mm] [mm] [mm] [mm] [mm] [Kg] DCL / DML DCL / DML DCL / DML DCL / DML DCL / DML DCL / DML DCL / DML DCL / DML DCL / DML A L D1 D2 Net weight [mm] [mm] [mm] [mm] [Kg] DCL / DML DCL / DML DCL / DML DCL / DML DML DCL / DML DCL / DML DCL / DML Danfoss DCS (az) DKRCC.PD.EB0.C H
14 Dimensions and weights (continued) Solder connection (cu-plated steel connectors) Danfoss 23Z80.10 A A1 A2 B L D1 D2 Net weight [mm] [mm] [mm] [mm] [mm] [mm] [mm] [Kg] DCL / DML 032s DCL / DML 032.5s DCL / DML 033s DCL / DML 034s Danfoss 23Z81.10 A A1 A2 B L D1 D2 Net weight [mm] [mm] [mm] [mm] [mm] [mm] [mm] [Kg] DCL / DML 052s DCL / DML 052.5s DCL / DML 053s DCL / DML 054s DCL / DML 055s Danfoss DCS (az) DKRCC.PD.EB0.C H
15 Dimensions and weights (continued) Solder connection (cu-plated steel connectors) Danfoss 23Z82.10 A A1 A2 B L D1 D2 Net weight [mm] [mm] [mm] [mm] [mm] [mm] [mm] [Kg] DCL / DML 082s DCL / DML 082.5s DCL / DML 083s DCL / DML 084s DCL / DML 085s DCL / DML 162s DCL / DML 162.5s DCL / DML 163s DCL / DML 164s DCL / DML 165s DCL / DML 166s DCL / DML 167s Danfoss DCS (az) DKRCC.PD.EB0.C H
16 Dimensions and weights (continued) Solder connection (cu-plated steel connectors) Danfoss 23Z83.10 A B L D1 D2 Net weight [mm] [mm] [mm] [mm] [mm] [Kg] DCL / DML 303s DCL / DML 304s DCL / DML 305s DCL / DML 306s DCL / DML 307s DCL / DML 309s DCL / DML 414s DCL / DML 415s DCL / DML 417s DCL / DML 419s DCL / DML 604s DCL / DML 606s DCL / DML 607s DCL / DML 609s DCL / DML 757s DCL / DML 759s Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary eady agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. Danfoss DCS (az) DKRCC.PD.EB0.C H
ELIMINATOR Hermetic filter drier Types DML and DCL
MAKING MODERN LIVING POSSIBLE Data sheet ELIMINATOR Hermetic filter drier Types DML and DCL All ELIMINATOR driers have a solid core with binding material held to an absolute minimum. There are two types
More informationELIMINATOR Hermetic filter drier Types DCL and DML
Data sheet ELIMINATOR Hermetic filter drier s DCL and DML All ELIMINATOR driers have a solid core with binding material held to an absolute minimum. There are two types of ELIMINATOR cores. DML driers
More informationELIMINATOR Hermetic bi-flow filter drier Types DMB and DCB
Data sheet ELIMINATOR Hermetic bi-flow filter drier s DMB and DCB Hermetic bi-flow filter driers, types DMB and DCB are for use in liquid lines on heat pumps. Hermetic bi-flow filter driers have built-in
More informationELIMINATOR Hermetic bi-flow filter drier Types DMB and DCB
Data sheet ELIMINATOR Hermetic bi-flow filter drier s DMB and DCB Hermetic bi-flow filter driers, types DMB and DCB are for use in liquid lines on heat pumps. Hermetic bi-flow filter driers have built-in
More informationEliminator Liquid line filter driers, type DCL and DML
Eliminator Liquid line filter driers, type DCL and DML Flare connection Solder connection (copper) REFRIGERATION AND AIR CONDITIONING Technical leaflet Eliminator Liquid line filter driers, type DCL and
More informationMAKING MODERN LIVING POSSIBLE. Eliminator Liquid line filter driers, DCL and DML. Flare connection. Solder connection (copper) Technical brochure
MAKING MODERN LIVING POSSIBLE Eliminator Liquid line filter driers, DCL and DML Flare connection Solder connection (copper) Technical brochure Contents Page Introduction........................................................................................
More informationCrankcase pressure regulator Type KVL
Data sheet Crankcase pressure regulator KVL Crankcase pressure regulator type KVL is fitted in the suction line ahead of the compressor. KVL protects the compressor motor against overload during start-up
More informationCrankcase pressure regulator Type KVL
Data sheet Crankcase KVL KVL crankcase are used to protect the compressor motor against overload experienced during startup after long off periods or just after defrost periods. They are installed in the
More informationTechnical brochure Eliminator filter drier DCR - with replaceable solid core
MAKING MODERN LIVING POSSIBLE Technical brochure Eliminator filter drier DCR - with replaceable solid core www.danfoss.com Contents Page Introduction...3 Features...3 Approvals...3 Technical data...4 of
More informationHANDBOOK REFRIGERATING SYSTEM PROTECTORS. Ed REFRIGERATING SYSTEM PROTECTORS DP-ED 01/ ENG 1
HANDBOOK Ed. 2017 DP-ED 01/2017 - ENG 1 CHAPTER 3 Hermetic filter driers CERTIFIED BY UNDERWRITERS LABORATORIES INC. For refrigeration plants that use HCFC, HFC or HFO refrigerants APPLICATIONS The filters
More informationReplaceable solid cores filter driers type CSR
Replaceable solid cores filter driers type CSR N of cores Nominal volume [cm 3 ] (in 3 ) DIMENSIONS AND TECHNICAL CHARACTERISTICS Filtering surface ODS Ø [in.] [mm] ØD1 ØD2 H1 P E H K CSR485 5/8" 16 148
More informationFDB Filter Drier. FDB Filter Drier. Technical Data
Technical Data ALCO FDB is a hermetic filter-drier in compacted bead style for use on liquid line. Features Compacted bead style (spring loaded) Hermetic design Rugged steel shells Cushioned flow for non-turbulent
More informationADK Filter Drier. Alco Controls. Filter Drier. Features
ADK is a hermetic filter-drier with internal solid block for use on liquid line. Features Solid block Hermetic design Rugged steel shells Corrosion resistant epoxy paint Solder connection made from copper
More informationFDB Filter Drier. Alco Controls. FDB Filter Drier. Features. Introduction. Moisture removal capability. Construction
ALCO FDB is a hermetic filter-drier in compacted bead style for use on liquid line. Features Compacted bead style (spring loaded) Hermetic design Rugged steel shells Corrosion resistant epoxy paint Solder
More informationCrankcase pressure regulator Type KVL
MAKING MODERN LIVING POSSIBLE Data sheet Crankcase pressure regulator KVL Crankcase pressure regulator type KVL is fitted in the suction line ahead of the compressor. KVL protects the compressor motor
More informationBFK Bi-flow Filter Drier
ALCO is a hermetic Bi-flow filter-drier in solid block style for use on liquid line in reversible refrigeration systems such as heat pump units. Features Solid block style Integrated check valves insure
More informationUni-Flow Filter Driers
STNDRD Uni-Flow Driers The filter driers of series DTG are used in refrigeration system with unidirectional flow to absorb moisture and acid in the system and to filter out the impurities. FETURES HIGH
More informationDCY. Anti-acid filter driers Refrigeration & Climate Components Solutions. n Applications
1.12 n Applications Filtering and drying of refrigerants and acid neutralization for liquid lines of refrigerating and air conditioning installations. n Functional features Products are compatible with
More informationJune 2015 / BULLETIN Catch-All. Liquid & Suction Line Filter-Driers FILTER-DRIERS. It s the CORE that counts!
June 2015 / BULLETIN 40-10 Catch-All Liquid & Suction Line Filter-Driers FILTER-DRIERS It s the CORE that counts! Page 2 Bulletin 40-10 Table of Contents The Sporlan Catch-All Liquid and Suction Line Filter-Driers
More informationREFRIGERANT RECOVERY PRODUCTS
REFRIGERANT RECOVERY PRODUCTS PARKER REFRIGERANT RECOVERY PRODUCT Parker provides a large selection of components for recovery, recycle and reclaim machines, protecting them from the many types of contaminants
More informationHot gas bypass regulator type CPCE Liquid gas mixer type LG (accessory)
MAKING MODERN LIVING POSSIBLE Data sheet Hot gas bypass regulator type CPCE Liquid gas mixer type LG (accessory) A CPCE hot gas bypass regulator is used to adapt compressor capacity to actual evaporator
More informationAnti-acid filter driers DCY
1.1 n Applications Filtering and drying of refrigerants and acid neutralization for liquid lines of refrigerating and air conditioning installations. n Functional features o Products are compatible with
More informationHANDBOOK REGULATOR VALVES. Ed REGULATOR VALVES RP-ED 01/ ENG 1
HANDBOOK Ed. 2017 RP-ED 01/2017 - ENG 1 CHAPTER 2 CRANKCASE PRESSURE REGULATORS For refrigeration plants that use HCFC or HFC refrigerants shutter continues to open, until the stroke limit is reached and
More informationFILTER DRIERS PART NUMBER SIGNIFICANCE LIQUID LINE FILTER DRIERS TOTALINE LIQUID LINE FILTER DRIER PHYSICAL DATA DIMENSIONS
TOTALINE LIQUID LINE FILTER DRIERS P502-8 SERIES P PART NUMBER SIGNIFICANCE P353 FEATURES Compacted bead filter drier Universal Replacement CFC, HCFC, HFC refrigerants Filtration first for more effective
More informationR-22 R-404A/R-502/R-507A R-12/
EMERSON CLIMATE TECHNOLOGIES-System Protectors Recommended System Tonnage Take-Apart Liquid Line Filter Driers in Tons* Description, Low Temp. & Commercial Installations Air Conditioning Field Replacement
More informationParker TEV Model Visual
PARKER - THERMOSTATIC EXPANSION VALVES TXV MODEL NUMBER SELECTION Parker TEV Model Visual N Series TEV C(E) Series TEV SC(E) Series TEV Applications: Applications: Applications: Low Profile Coolers, Rail
More informationHANDBOOK PIPING ACCESSORIES. Ed PIPING ACCESSORIES AT-ED 01/ ENG 1
HANDBOOK Ed. 2017 AT-ED 01/2017 - ENG 1 CHAPTER 3 ACCESS FITTINGS AND VALVE CORES FOR REFRIGERATION PLANTS THAT USE HCFC, HFC, HC, HFO, OR R744 REFRIGERANTS APPLICATIONS The access fittings illustrated
More informationA full line of field-tested CO 2 controls, stocked for your convenience
A full line of field-tested controls, stocked for your convenience 7000+ systems built with products www.danfoss.us/aftermarket Why choose for? has pioneered technologies for both transcritical and subcritical
More informationAIR CONDITIONING COMMERCIAL REFRIGERATION HEAT PUMP STANDARD PRODUCT
AIR CONDITIONING COMMERCIAL REFRIGERATION HEAT PUMP STANDARD PRODUCT SANHUA Strive for perfection, Pursuit of excellence Sanhua is a leading HVAC&R manufacturer of controls and components with a global
More informationTAKE-A-PART SHELLS TOTALINE LIQUID & SUCTION LINE REPLACEABLE SHELLS P505-8 SERIES PART NUMBER SIGNIFICANCE
TOTALINE LIQUID & SUCTION LINE REPLACEABLE SHELLS P505-8 SERIES P PART NUMBER SIGNIFICANCE P360 SIZE (in 1/8 ) 505-8 TOTALINE FILTER DRIER SHELLS APPLICATION Totaline Replaceable Core Shells offer the
More informationSight glass (High pressure) Type SGP X, SGP I, SGP N, SGP RX, SGP RI and SGP RN
Sight glass (igh pressure) SGP X, SGP I, SGP N, SGP RX, SGP RI and SGP RN SGP are sight glasses for high pressure applications (Max. Working Pressure 52 bar / 754 psig). SGP is available with flare, solder
More informationThermostatic Expansion Valve
STANDARD Thermostatic Expansion Valve RFKH series thermostatic expansion valves are used to adjust mass flow of refrigerant into the evaporator while controlling the refrigerant s superheat at the outlet
More informationPRODUCT DATA DTG SERIES Unidirectional Filter Driers
The series DTG unidirectional filter-driers are used to protect air conditioning and refrigeration systems from moisture and contamination. FEATURES HIGHLY EFFICIENT IN MOISTURE AND CONTAMINATION REMOVAL
More informationREFRIGERANTS AND LUBRICANTS
Service Engineers Section Bulletin No 10 REFRIGERANTS AND 1.0 INTRODUCTION - THE NEED FOR IN REFRIGERATION SYSTEMS Lubricants (oils) are required in refrigeration systems to: Reduce friction by interposing
More informationHANDBOOK SOLENOID VALVES. Ed SOLENOID VALVES VS-ED 01/ ENG 1
HANDBOOK Ed. 2017 1 CHAPTER 5 NORMALLY-CLOSED FOR REFRIGERATION PLANTS THAT USE HC REFRIGERANTS APPLICATION The solenoid valves illustrated in this chapter have been developed by Castel for all those refrigeration
More informationFILTER DRIERS - SPORLAN
FILTER DRIERS - SPORLAN The universal acceptance of the Catch-All Filter-Drier is due to its unique moulded porous core, consisting of a blend of highly effective desiccants. The quality features built
More informationThermostatic expansion valves Type TGE 10, TGE 20 and TGE 40
MAKING MODERN LIVING POSSIBLE Data sheet Thermostatic expansion valves Type TGE 10, TGE 20 and TGE 40 TGE is a dedicated designed series of thermostatic expansion valves for all standard refrigerants including
More informationHANDBOOK SOLENOID VALVES. Ed SOLENOID VALVES VS-ED 01/ ENG 1
HANDBOOK Ed. 2017 VS-ED 01/2017 - ENG 1 CHAPTER 3 NORMALLY-CLOSED PULSE FOR REFRIGERATION PLANTS THAT USE HFC OR HFO REFRIGERANTS APPLICATION The solenoid valves illustrated in this chapter are designed
More informationEMERSON CLIMATE TECHNOLOGIES
STAS STEEL TAKE-APART FILTER DRIER APPLICATION Replaceable core filter-drier for CFC, HCFC and HFC refrigerants for use in large commercial air conditioning and refrigeration systems. FEATURES Unique internal
More informationHANDBOOK VALVES. Ed VALVES VR-ED 02/ ENG 1
HANDBOOK Ed. 2017 1 CHAPTER 1 WITH SCREW SHUTTER FOR REFRIGERATION PLANTS THAT USE HCFC, HFC OR HFO REFRIGERANTS APPLICATIONS All valves illustrated in this chapter are designed for installation on commercial
More informationWEIGHT (lb) PART NO WITH ACCESS CONNECTION (ODS) BALL PORT DIAMETER WA WAS
SUPERIOR - BALL VALVES WA SERIES (WELDED) WAS Series (Welded with Access Fittings) Full Service Temperature Range of -40 F to +325 F. Forged Brass Body and Seal Cap. Design Working Pressure: 700 psig.
More informationRefrigeration K-211. Replacement Parts. Chillers, Condensers. Compressors, Motors. Electrical. Components. Heating. Indoor Air Quality.
EMERSON CLIMATE TECHNOLOGIES-Oil Controls High Efficiency Centrifugal Oil Separator The High Efficiency Centrifugal Oil Separator is used in ultra-low temperature systems with long refrigerant lines or
More informationManeurop reciprocating compressors MT - MTZ - NTZ
MAKING MODERN LIVING POSSIBLE Quick reference Maneurop reciprocating compressors MT - MTZ - NTZ 60 Hz - R404A - R507A - R407C - R134a - R22 - R417A www.cc.danfoss.com Quick reference Dimensions Ø D ø
More informationReliable season change
New perspectives with Danfoss Saginomiya 4 - Way Reversing Valves Reliable season change, VHV 4-way reversing valves Wide application range - complete capacity range - available for all common refrigerants
More informationHANDBOOK SOLENOID VALVES. Ed SOLENOID VALVES VS-ED 01/ ENG 1
HANDBOOK Ed. 2017 VS-ED 01/2017 - ENG 1 2 VS-ED 01/2017 - ENG TABLE OF CONTENTS CHAPTER 1 CHAPTER 2 CHAPTER 3 CHAPTER 4 CHAPTER 5 CHAPTER 6 CHAPTER 7 CHAPTER 8 CHAPTER 9 CHAPTER 10 CHAPTER 11 CHAPTER 12
More informationON/OFF zone valves AMZ 112, AMZ 113
Data sheet ON/OFF zone valves AMZ 112, AMZ 113 Description The ON/OFF zone valves type AMZ 112 and AMZ 113 are typical used in connection with: Domestic and commercial central heating applications Domestic
More informationCrankcase Pressure Regulating Valves
Crankcase Regulating Valves Crankcase Regulating Valves are designed to prevent overloading of the compressor motor by limiting the crankcase pressure to a predetermined maximum value during and after
More informationSubcritical CO 2 Innovations
March 2011 / CATALOG 744 Subcritical CO 2 Innovations Energy Conscious Products & Solutions for Supermarkets Subcritical CO 2 Innovations Energy Conscious Products & Solutions for Supermarkets CATALOG
More informationPerformer scroll compressors. SM - SY - SZ R407C - R134a - R22-50 Hz QUICK REFERENCE MAKING MODERN LIVING POSSIBLE
MAKING MODERN LIVING POSSIBLE Performer scroll compressors SM - SY - SZ R407C - R134a - R22-50 z REFRIGERATION & AIR CONDITIONING DIVISION QUICK REFERENCE PRODUCT RANGE SINGLE COMPRESSORS 0 D ØD Ø D ØD
More informationThe Danfoss Turbocor Portfolio of Oil Free Compressors
Fact Sheet Models TT, TG, and VTT The Danfoss Turbocor Portfolio of Oil Free Compressors Highly efficient compressors that reduce OEMs operating and maintenance costs Capacity range from 140 to 1400 kw
More informationElectric expansion valve Type AKV 10P, AKV 10PS
Data sheet Electric expansion valve Type AKV 10P, AKV 10PS AKV 10P and AKV10PS are electric operated expansion valves designed for refrigerating plants. The AKV 10P and AKV 10PS valves are normally controlled
More informationATEX instruction for APP / PAH PAHT G 2-90 / PAH Tech
MAKING MODERN LIVING POSSIBLE Instruction ATEX instruction for APP 0.6-10.2 / PAH 2-100 PAHT G 2-90 / PAH 25-80 Tech danfoss.high-pressurepumps.com Table of Contents 1. Common demands for Category 2 and
More informationElectric expansion valves Type ETS 6
MAKING MODERN LIVING POSSIBLE Data sheet Electric expansion valves Type ETS 6 The range of Electric expansion valves are based on many years of experience. ETS 6 secure reliability and provide a precise
More informationPAH / PAHT / PAHT G pumps
Lenntech info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 Instruction PAH / PAHT / PAHT G 10-12.5 pumps Instruction Pump instruction PAH / PAHT / PAHT G 10-12.5 Table of Contents
More informationMAKING MODERN LIVING POSSIBLE. Performer scroll compressors. SM - SY - SZ R407C - R134a - R22-50 Hz. Quick reference
MAKING MODERN LIVING POSSIBLE Performer scroll compressors SM - SY - SZ R407C - R134a - R22-50 z Quick reference PRODUCT RANGE SINGLE COMPRESSORS Ø D Ø D 0 D 2 2 2 1 1 1 D 1 2 S084-090-100 254 508 142
More informationPressure operated water valve Type WVFX and WVS
Data sheet Pressure operated water valve WVFX and WVS Pressure operated water valves types WVFX and WVS are used for regulating the flow of water in refrigeration plants with water-cooled condensers. The
More informationAPP pump instruction APP and APP 16-22
MAKING MODERN LIVING POSSIBLE Instruction APP pump instruction APP 11-13 and APP 16-22 www.ro-solutions.com Table of Contents 1. Identification...2 2. System design...3 2.1 Open-ended systems with direct
More informationThe precise step to take
New perspectives with Danfoss Saginomiya Electronic Expansion Valves The precise step to take Type KV Electronic Expansion Valves Energy efficiency Precision flow control with high resolution Compact and
More informationDanfoss VDHT Solenoid Valves WATER SOLUTIONS
Danfoss VDHT Solenoid Valves danfoss HIGH-PRESSURE WATER SOLUTIONS What is a Danfoss VDHT valve? Facts and benefits The VDHT solenoid valve programme consists of both single valves and manifold block solutions
More informationDanfoss Saginomiya 4 - Way Reversing Valves
New perspectives with anfoss Saginomiya - Way Reversing Valves Reliable season change ST, VHV -way reversing valves Wide application range - complete capacity range - available for all common refrigerants
More informationElectrical Control Valves Series EX4, EX5, EX6, EX7 & EX8
Electrical Control s Series EX4, EX5, EX6, EX7 & EX8 Features Multifunction as expansion valve, hot gas bypass, suction gas throttling, head pressure, liquid level actuator etc. Fully hermetic design (no
More informationHANDBOOK EXPANSION VALVES. Ed EXPANSION VALVES VE-ED 01/ ENG 1
HANDBOOK Ed. 2017 VE-ED 01/2017 - ENG 1 CHAPTER 12 STEP-MOTOR CERTIFIED BY UNDERWRITERS LABORATORIES INC. FOR REFRIGERATION PLANTS THAT USE HCFC, HFC OR HFO REFRIGERANTS belonging to Group 2, as defined
More informationIntegrated Valve with Presetting for Manifolds in Two-Pipe Heating Systems
Data Sheet Integrated Valve with Presetting for Manifolds in Two-Pipe Heating Systems The integrated valve is designed for manifold applications in combination with a system connection piece. Valve and
More informationThermostatic Expansion
Thermostatic Expansion Valves Thermostatic Expansion Valves TCCE Series Application TCCE thermostatic expansion valve is used to regulate refrigerant flow into the evaporator, especially in applications
More informationFlow-compensated temperature controller AVTQ DN 15
Data sheet Flow-compensated temperature controller AVTQ DN 15 Description AVTQ is a self-acting flow-compensated temperature controller primarily for use in district heating systems with plate heat exchangers
More informationTechnical brochure Electrically operated expansion valves, type ETS 6
MAKING MODERN LIVING POSSIBLE Technical brochure Electrically operated expansion valves, type ETS 6 With many years of experience the current range of Electronic Expansion Valves offers high reliability
More informationSelection & Application Guidelines Performer scroll compressors in parallel installation
Selection & Application Guidelines Performer scroll compressors in parallel installation R22 - R407C - R134a CONTENTS GENERAL OVERVIEW...p 4 Benefits... p 4 Scope... p 4 Design challenge... p 4 Oil equalisation...
More informationFilter solutions for Danfoss PAH, APP and CLP pumps
MAKING MODERN LIVING POSSIBLE Technical data sheet Lenntech info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 Filter solutions for Danfoss PAH, APP and CLP pumps 521B1009 / dkcfn.pd.090.a4.02
More informationSolenoid valves Type EVU for fluorinated refrigerants
Data sheet Solenoid valves EVU for fluorinated refrigerants EVU solenoid valves are designed to fit into compact refrigeration systems. Available in direct and pilot operated versions, they can be applied
More informationMAKING MODERN LIVING POSSIBLE. Solenoid valves Type EVU for fluorinated refrigerants REFRIGERATION AND AIR CONDITIONING.
MAKING MODERN LIVING POSSIBLE Solenoid valves EVU for fluorinated refrigerants REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction... 3 Features... 3 Approvals... 3 Technical
More informationATEX instruction APP S 674 pumps APP S , APP S and APP S
MAKING MODERN LIVING POSSIBLE Instruction APP S 674 2.0-3.5, APP S 674 5.1-9.0 and APP S 674 21-38 ro-solutions.com Table of Contents 1. General information....2 2. Common demands for Category 2 and 3
More informationModulating liquid level regulators, direct-controlled SV 1 and SV 3
MAKING MODERN LIVING POSSIBLE Technical brochure Modulating liquid level regulators, direct-controlled SV 1 and SV 3 The SV 1 and 3 can be used separately as a modulating liquid level regulator in refrigerating,
More informationAPP pump instruction APP 21-43
MAKING MODERN LIVING POSSIBLE Instruction APP pump instruction APP 21-43 ro-solutions.com Table of Contents 1. Identification...2 2. System design...3 2.1 Open-ended systems with direct water supply....3
More informationPulse Width Modulation Valves. Models SPW-0 thru -7
November 2017 Bulletin / Bulletin 30-30 30-30 Page 1 Pulse Width Modulation s Models SPW-0 thru -7 Page 2 Bulletin 30-30 Pulse Width Modulation s For Refrigerant Flow Control in Direct Expansion HFC, HCFC
More informationSolenoid valves Type EVR 2 40 NC/ NO REFRIGERATION AND AIR CONDITIONING. Technical leaflet
Solenoid valves EVR 2 40 NC/ NO REFRIGERATION AND AIR CONDITIONING Technical leaflet 2 DKRCCPDBB0A202-520H275 Danfoss A/S, 0-2006 Contents Page Introduction.......................................................................................
More informationElectrical Control Valves
172 Electrical Control Valves Electrical Control Valves Electrical Control Valve Technology Thermostatic expansion valves and mechanical regulator valves have been used in the refrigeration and air conditioning
More informationReliable season change
ew perspectives with anfoss Saginomiya 4 - Way Reversing Valves Reliable season change ST, VHV 4-way reversing valves Wide application range - complete capacity range - available for all common refrigerants
More informationHANDBOOK VALVES. Ed VALVES VR-ED 02/ ENG 1
HANDBOOK Ed. 2017 1 2 INDEX CHAPTER 1 CHAPTER 2 CHAPTER 3 CHAPTER 4 CHAPTER 5 CHAPTER 6 CHAPTER 7 CHAPTER 8 CHAPTER 9 CHAPTER 10 CHAPTER 11 CHAPTER 12 CHAPTER 13 CHAPTER 14 Valves with screw shutter For
More informationHigh Capacity Valve Body, Type RA-G
Data Sheet The RA-G valves are fitted with a grey protective cap. This protective cap must not be used as a manual shut off device. A special manual shut off device is available (code no. 013G3300). Application
More informationOil separator Type OUB
ata sheet Oil separator OUB Oil separator type OUB is for use in all refrigeration plants where the compressor lubricating oil must be returned directly to the compressor oil sump under all operating conditions.
More informationK-LINE. VS Replaceable Core Filter Driers
K-LINE VS Replaceable Core Filter Driers The 48 series of replaceable filter core driers is suited to liquid and suction line applications in a range of K-LINE VS Replaceable Core Filter Driers connection
More informationValve bodies type RA-N with integrated presetting
Data Sheet Application Straight version Angle version Left mounted angle version Horizontal angle version All RA-N valve bodies can be used together with all types of thermostatic elements in the RA 2000
More informationChanging pistons APP and APP 16-22
MAKING MODERN LIVING POSSIBLE Instruction Changing pistons APP 11-13 and APP 16-22 ro-solutions.com Contents 1. Disassembling...3 2. Assembling...5 3. When should the pistons be replaced?....7 This document
More informationAPP S pumps APP S / APP S / APP S 21-38
MAKING MODERN LIVING POSSIBLE Instruction APP S 2.0-3.5 / APP S 5.1-9.0 / APP S 21-38 ro-solutions.com Instruction Table of Contents 1. Identification...2 2. System design...3 2.1 Open system design...3
More informationOptyma TM Slim Pack Just mount, braze and plug
MAKING MODERN LIVING POSSIBLE Catalogue Optyma TM Slim Pack Just mount, braze and plug R404A/R507 - R34a www.danfoss.com Content The new cost effective outdoor solution... 4 Features and cooling capacity...
More informationSelection & Application guidelines. Condensing Units 50 Hz - 1, 2, 4 cylinders R22 - R134a - R404A / R507 REFRIGERATION AND AIR CONDITIONING
Selection & Application guidelines Condensing Units 50 Hz - 1, 2, 4 cylinders R22 - R134a - R404A / R507 REFRIGERATION AND AIR CONDITIONING www.danfoss.com 50 HZ BLUESTAR PRODUCT PROGRAMME....... p 3 Product
More informationR134a R134a R13. 4a R134a R134a R134
Product Information Compressors for Refrigerant R134a 12-24 olt Direct Current Compressors a R R134a R 34a R134a R1 R134a R134a R13 4a R134a R134a R134 R134a R134a R134a R134a 34a R134a R134a R134a R134a
More informationMAKING MODERN LIVING POSSIBLE. Residential and light commercial scroll compressors R407C - R22 - R410A 60 HZ QUICK REFERENCE
MAKING MODERN LIVING POSSIBLE Residential and light commercial scroll compressors R407C - R22 - R410A 60 HZ QUICK REFERENCE DIMENSIONS Ø 9.41 Ø 7.5 Ø 9.41 Ø 7.5 Ø 9.13 Ø 7.5 Ø 9.41 Ø 7.5 D D D D H2 H H2
More information00% Optyma Plus TM New Generation Plug and play solution. Catalogue. R404A/R507, R134a MAKING MODERN LIVING POSSIBLE.
MAKING MODERN LIVING POSSIBLE Catalogue Optyma Plus TM New Generation Plug and play solution R404A/R507, R134a 00% Text in bar Equipis atet nit ulput pratum zzril delent lam, con ut in vercing ea adit.
More informationControl Card VLT FC Series
These instructions describe the replacement of the control card in: VLT HVAC Drive FC 102. VLT Refrigeration Drive FC 103. VLT AQUA Drive FC 202. VLT AutomationDrive FC 301/FC 302. VLT Lift Drive LD 302.
More informationTable of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10
Table of Contents Page No. 1. Model Designation And Unit Models 1 2. Features 2 3. Guide Specifications 4 4. Standard Unit Components 5 5. Technical Data 6 6. Performance Data 10 7. Electrical Data 19
More informationInstallation Guide. VLT Real-time Clock MCB 117 VLT HVAC Drive FC 102, VLT Refrigeration Drive FC 103, VLT AQUA Drive FC 202, VLT AutomationDrive
Installation Guide VLT Real-time Clock MCB 117 VLT HVAC Drive FC 102, VLT Refrigeration Drive FC 103, VLT AQUA Drive FC 202, VLT AutomationDrive FC 301/FC 302 Installation Guide VLT Real-time Clock MCB
More informationSOLENOID VALVES FOR REFRIGERATING SYSTEMS
SOLENOID VALVES 17 SOLENOID VALVES FOR REFRIGERATING SYSTEMS APPLICATIONS The solenoid valves, shown in this chapter, are classified Pressure accessories in the sense of the Pressure Equipment Directive
More informationPressure independent control valve with integrated flow limiter AVQM (PN 16) - return and flow mounting
Data sheet Pressure independent control valve with integrated flow limiter AVQM (PN 16) - return and flow mounting Description Controllers are used together with Danfoss electrical actuators: AMV 0 1)
More informationCombined automatic balancing valve AB-PM valve DN 10-32, PN 16
Data sheet Combined automatic balancing valve AB-PM valve DN 10-32, PN 16 Description AB-PM is a combined automatic balancing valve. It features three function in compact valve body: 1. Differential pressure
More information00% Optyma Plus TM New Generation Plug and play solution. Catalogue. R404A/R507, R134a MAKING MODERN LIVING POSSIBLE.
MAKING MODERN LIVING POSSIBLE Catalogue Optyma Plus TM New Generation Plug and play solution R404A/R507, R134a 00% Text in bar Equipis atet nit ulput pratum zzril delent lam, con ut in vercing ea adit.
More informationThermostatic Expansion Valve
STANDARD Thermostatic Expansion Valve RFGD series thermostatic expansion valves are used to adjust mass flow of refrigerant into the evaporator while controlling the refrigerant s superheat at the outlet
More informationPressure relief controller AVA (PN 25)
Data sheet Pressure relief controller AVA (PN 25) Description AVA is a self-acting pressure relief controller primarily for use in district heating systems. The controller is normally closed and opens
More information3/2-Way Zone-Drain-Valves VDHT 2E, VDHT 15E and VDHT 15EC
Lenntech info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 3/2-Way Zone-Drain-Valves VDHT 2E, VDHT 15E and VDHT 15EC danfoss.high-pressurepumps.com General information The 3/2
More informationSolenoid valve Types EVR 2 EVR 40 NC/NO
MAKING MODERN LIVING POSSIBLE Data sheet Solenoid valve s EVR 2 EVR 40 NC/NO EVR is a direct or servo operated solenoid valve for liquid, suction, and hot gas lines with fluorinated refrigerants. EVR valves
More information