SPCC Marina Inspection Update Oklahoma Marina Association Inspector Tom McKay
|
|
- Roland Smith
- 5 years ago
- Views:
Transcription
1 SPCC Marina Inspection Update Oklahoma Marina Association Inspector Tom McKay
2 Recent Compliance Assistance Documents 40 CFR 112 Final & Most Recent Regulation (7/1/15) Latest SPCC Inspection Checklists (6/1/2014) SPCC Guidance for Regional Inspectors (8/28/13 Update Pending) SPCC & FRP Workshop for Onshore Facilities (Scheduling) in Addison, TX
3 SPCC Inspection Process Facility Inspection Targeting History of non-compliance Spill history of an geographic area Spill Responses ** Distance to navigable waters Proximity to sensitive ecosystems Citizen Complaints ** State/Federal referrals **
4 The Most Common SPCC Violations At Marinas
5 No SPCC Plan Common Violation Commonly found at facilities that did not know that they were regulated Small facilities Facilities that had been purchased but had not put together a plan yet. 5
6 No PE Certification Common Violation PE certifies that the facility s equipment, design, construction, and maintenance procedures used to implement the Plan are in accordance with good engineering practices. PE certification must be completed in accordance with law of the state in which the PE is working Generally certification includes: Name Registration number and State Date of Certification PE seal affixed to Plan 6
7 Qualified Facility Applicability If the facility total aboveground oil storage capacity is 10,000 gallons or less And And the facility has Then the facility is a: Within three years prior to the Plan certification date, or since becoming subject to the SPCC rule if in operation for less than three years, the facility has not had: A single discharge of oil to navigable waters or adjoining shorelines exceeding 1,000 gallons, or Two discharges of oil to navigable waters or adjoining shorelines each exceeding 42 gallons within any 12-month period. 1 No individual aboveground oil containers greater than 5,000 gallons; Any individual aboveground oil container greater than 5,000 gallons; Tier I Qualified Facility: Complete and self-certify Plan template (Appendix G to 40 CFR part 112) in lieu of a full PE-certified Plan. Tier II Qualified Facility: Prepare a self-certified Plan in accordance with all applicable requirements of and subparts B or C of the rule, in lieu of a PEcertified Plan.
8 No Records Common Violation Owner/operator does not have records of inspections or tests and spill prevention training. Facility maintains very generic records that do not cover all of the requirements of the rule. Common to hear that they do inspections, but do not write them down. Lack of 5-Year Plan Review ** 8
9 Totes and Drums not in secondary containment Common Violation
10
11 No General Containment for Loading Areas Pump dispensers w/out general containment Load-line w/out general containment
12 No Secondary Containment
13
14
15 Secondary Containment Appears Inadequate Inadequate containment Inadequate containment
16 Containment Not Impervious To Contain Oil Cracks in concrete containment Cracks in cinder-block containment
17 Piping and Valve Issues
18 Lack of Tank Integrity Testing Protocols SPCC Plan Requirements Identify Standard Used STI SP001 Best Standard for Marinas API 653 Identify Inspection and Testing Protocols External inspection Shell Testing(ultrasonic) Implementation Conduct & Record external inspections per standard used Conduct & Record Nondestructive shell thickness testing; ie ultrasonic or hydrostatic.
19 STI SP001 Inspection Protocols An assigned knowledgeable marina employee conducts periodic inspections of all marina shop-built Above Ground Storage Containers (ASTs) Records of inspections consist of the monthly and annual inspection checklist in the Steel Tank Institute (STI) SP001 Standard
20 STI SPOO1 Inspection Protocols For Typical Marina Tanks
21 STI SP001 - Spill Control and CDRM CONTINUOUS RELEASE DETECTION METHOD (CRDM) a means of detecting a release of liquid through inherent design. Examples of CDRM: Secondary containment AST, including double-wall AST Elevated AST, with or without release prevention barrier. SPILL CONTROL - a means of preventing a release of liquid to the environment, including adjoining property and waterways. Spill control methods include : Secondary containment dike/berm Secondary containment AST Secondary containment system
22 Typical Marina Tank Configuration Within the SP001 Standard
23
24
25 Marinas With Underground Storage Tanks USTs are exempt from SPCC regulatory requirements as long as the facility follows 40 CFR 280 and/or 281. Most marinas incorporate Oklahoma UST protocols administered by the Oklahoma Corporation Commission Petroleum Storage Tank Division.
26 SPCC Plan Maintenance & Housekeeping * Review and Update Your SPCC Plan Most members were brought into compliance in 2009 Plans should have been updated by 11/10/2011 to incorporate new regulatory amendments. * Must document Plan review and evaluation. Sign statement at beginning or end of Plan or in a log or an appendix: I have completed review and evaluation of the SPCC Plan for (name of facility) on (date), and will (will not) amend the Plan as a result. PE must certify any technical amendment to Plan.
27 Continued SPCC Maintenance Keep current on overall facility inspection records. Keep current on spill prevention training for oil & fuel handling personnel. Both inspection records and training records are required to be maintained with your plan for 3 years. Follow and document tank integrity inspection & testing protocols developed for your facility.
28 Continued SPCC Maintenance Tier II Tank Registration with ODEQ, Local Emergency Planning Committee (LEPC), and local fire department due annually on March 1 st Maintain requisite Material Safety Data Sheets (MSDS) for hazardous materials including fuel stored at your marina
29
30
31
32
33
34 Conclusions Emphasis upon joint inspections with both State and Federal Agencies. Our goal is to increase compliance awareness and improve response performance.
35 Contact Information Inspector Tom McKay Office Phone: (214)
Testing Requirements for UST s and AST s. By Mark Lindsey June 27 th, 2013
Testing Requirements for UST s and AST s. By Mark Lindsey June 27 th, 2013 http://www.tanknology.com/ Testing Requirements for UST s and AST s UST Testing Requirements: Owner/Operator must maintain on
More informationSPCC Regulation Integrity and Leak Testing Methods
SPCC Regulation Integrity and Leak Testing Methods NISTM New England December 3 rd, 2015 Founded in 1988, Tanknology has grown to become one of the largest testing and inspection service companies in the
More information1) Activity Description: Management of Petroleum Storage Tanks and Containers
ES-301-4.09 Management of Petroleum Storage Tanks and Containers Document Identification Number ES-301-4.09 Document Owner: John Hambright 1) Activity Description: Management of Petroleum Storage Tanks
More informationStorage Tank Risk Management Solutions Leak
Storage Tank Risk Management Solutions Leak Prevention and Tank Integrity Inspections for ASTs Brian Pine ATC Group Services NISTM 8th Annual Pennsylvania Storage Tank Conference 1 2 ATC GROUP SERVICES
More informationAST REGISTRATION PIPE INSPECTION PE REQUIREMENTS. David D. Bradeson, P.E. Chemung Contracting Corporation
AST REGISTRATION PIPE INSPECTION PE REQUIREMENTS David D. Bradeson, P.E. Chemung Contracting Corporation AST REGISTRATION REQUIRED 9 VAC 25-91-20 Part II individual tank of 660 gal. or greater or aggregate
More informationYOUR SPCC PROGRAM: A CHECK UP
YOUR SPCC PROGRAM: A CHECK UP Avoid Common Issues Seen with SPCC Programs Amy M. Reed, P.E. SAFETY MOMENT PEDESTRIAN/RUNNER SAFETY Stay on the sidewalk where sidewalks are provided it s the law! If you
More informationFuel Tank Management: PBS, USTs and the Energy Policy Act of 2005
Fuel Tank Management: PBS, USTs and the Energy Policy Act of 2005 Petroleum Bulk Storage 6NYCRR Part 612 614 EPA Underground Storage Tanks 40 CFR Part 280 PBS Program Overview PART 612 PART 613 PART 614
More informationChanges to EPA s AST & UST Rules. Mott-Smith Consulting Group, LLC
Changes to EPA s AST & UST Rules Mott-Smith Consulting Group, LLC Marshall T. Mott-Smith, President Mott-Smith Consulting Group, LLC 111 North Calhoun Street, Tallahassee, FL 32301 marshall@mott-smithconsulting.com
More informationUnderground Storage Tank. City of Burbank UST Owners & Operators
Underground Storage Tank City of Burbank UST Owners & Operators Created by: Kern County Environmental Health CUPA, Edited by: Burbank Fire Department for the Burbank Fire Department s use Burbank Fire
More informationECM environmental compliance monitoring, inc. 1
Regulated Storage Tanks & Automobile Dealerships in New York State Presented for NYSADA April 13, 2010 New York State Automobile Dealers Association By Scott Hubbard, C.H.M.M. of ECM environmental compliance
More informationSpill Prevention, Control, and Countermeasure. Training Module
Spill Prevention, Control, and Countermeasure Training Module Topics to Cover Introduction Regulatory Background Piedmont/US Airways SPCC Plans Introduction What is SPCC? Spill: Refers to major and minor
More informationU.S. ENVIRONMENTAL PROTECTION AGENCY TIER I QUALIFIED FACILITY SPCC PLAN TEMPLATE
U.S. ENVIRONMENTAL PROTECTION AGENCY TIER I QUALIFIED FACILITY SPCC PLAN TEMPLATE *Please note: Editorial comments for the purposes of this guidance document are identified by red italicized text to distinguish
More information04/08/2017. What Are The Environmental Regulatory Requirements/Programs Related To Aboveground Storage Tanks That I Have To Comply With?
What Are The Environmental Regulatory Requirements/Programs Related To Aboveground Storage Tanks That I Have To Comply With? Outline for Today s Discussion AST Regulations/Laws/Codes Typical AST Requirements
More informationPENNSYLVANIA ABOVE GROUND STORAGE TANKS
PENNSYLVANIA ABOVE GROUND STORAGE TANKS GZA GeoEnvironmental Inc. by Jeffrey Knepper, LRS, CPG July 27, 2017 PA CODE Chapter 245. Administration of the Storage Tank & Spill Prevention Program AST Definition
More informationTHE KEY RELATIONSHIPS BETWEEN FIRE CODES, NEW YORK AST REGULATIONS AND SPCC PLANS
THE KEY RELATIONSHIPS BETWEEN FIRE CODES, NEW YORK AST REGULATIONS AND SPCC PLANS Presented by: Joyce A. Rizzo President JD2 Environmental, Inc. 800 East Washington Street West Chester, PA 19380 www.jd2env.com
More informationOKLAHOMA CORPORATION COMMISSION PETROLEUM STORAGE TANK DIVISION THE ABC S OF AST S AN OVERVIEW OF ABOVEGROUND STORAGE TANK REQUIREMENTS
OKLAHOMA CORPORATION COMMISSION PETROLEUM STORAGE TANK DIVISION THE ABC S OF AST S AN OVERVIEW OF ABOVEGROUND STORAGE TANK REQUIREMENTS PO BOX 52000 OKC, OK 73152-2000 www.occeweb.com Created on 10/1/2008
More informationChanges to EPA s AST & UST Rules. Mott-Smith Consulting Group, LLC
Changes to EPA s AST & UST Rules Mott-Smith Consulting Group, LLC Marshall T. Mott-Smith, President Mott-Smith Consulting Group, LLC 111 North Calhoun Street, Tallahassee, FL 32301 marshall@mott-smithconsulting.com
More informationMassachusetts Department of Environmental Protection Underground Storage Tank Program
Massachusetts Department of Environmental Protection Underground Storage Tank Program Tom DeNormandie, Chief Underground Storage Tank and Stage I/II Branch 2016 New England Storage Tank Conference Westborough,
More informationINSPECTION, EVALUATION, AND TESTING
Chapter 7: Inspection, Evaluation, and Testing INSPECTION, EVALUATION, AND TESTING 7.1 Introduction Regularly scheduled inspections, evaluations, and testing by qualified personnel are critical parts of
More informationINTEGRITY INSPECTION OF ABOVE GROUND STORAGE TANKS. Frank Maitland, PE QUENSE LLC 136 Edgemere Avenue West Hartford, CT
ABSTRACT INTEGRITY INSPECTION OF ABOVE GROUND STORAGE TANKS Frank Maitland, PE QUENSE LLC 136 Edgemere Avenue West Hartford, CT 06110 860-232-8505 40 CFR 112.7 requires integrity inspection of containers
More informationCoordination with the Spill Prevention, Control, and Countermeasures Plan
1.0 Introduction Purpose of Plan This plan covers Petroleum Storage Tanks (PSTs) and Petroleum, Oil, & Lubricants (POL) storage, under the responsibility of Fort Gordon located in the City of Augusta,
More informationChanges to Chapter , Florida Administrative Code Underground Storage Tank Systems (USTs) Effective 1/11/2017
Changes to Chapter 62-761, Florida Administrative Code Underground Storage Tank Systems (USTs) Effective 1/11/2017 Rule Organization The rule sections are reorganized a bit with separate sections now for:
More informationAPPENDIX D: SPCC REQUIREMENTS OVERVIEW
SPCC Requirements Overview APPENDIX D: SPCC REQUIREMENTS OVERVIEW Preface. The following appendix contains an overview of SPCC requirements, presented both in matrices or timetables, and in a succinct
More informationPETROLEUM PRODUCT STORAGE TANK REGULATION SAFETY AND BUILDINGS DIVISION BUREAU OF PETROLEUM INSPECTION AND FIRE PROTECTION
PETROLEUM PRODUCT STORAGE TANK REGULATION SAFETY AND BUILDINGS DIVISION NOTE: THIS OUTLINE SHOULD NOT BE USED AS A DOCUMENT FOR DETERMINING AN OWNER'S SPECIFIC REQUIREMENTS FOR COMPLIANCE. THE FEDERAL
More informationSteel USTs: History and Trends. Wayne Geyer, STI/SPFA August 1, 2013
Steel USTs: History and Trends Wayne Geyer, STI/SPFA August 1, 2013 Who and What is STI/SPFA? Association of 180 fabricating and affiliate companies of steel construction products shopfab tanks, field
More informationNYSDEC CBS Compliance Requirements
NYSDEC CBS Compliance Requirements Peter J. Petriccione, P.E. H2M - Water September 24, 2015 Introduction Definition of a Hazardous Substance and a Chemical Bulk Storage Facility Design Requirements of
More informationPennsylvania DEP Aboveground Storage Tank Facility Visits NISTM PA CONFERENCE Washington, PA May 18, 2017
Pennsylvania DEP Aboveground Storage Tank Facility Visits 2017 NISTM PA CONFERENCE Washington, PA May 18, 2017 What one may expect Documentation review Tank system visual assessment Follow-up PADEP AST
More informationUnderstanding the Inspection Process for Owners and Operators
Underground Storage Tanks (UST s) Metal Integrity and Lining Inspections Understanding the Inspection Process for Owners and Operators Presented By: Robert L. McChan II General Manager/Senior Project Manager/Steel
More informationSafe Operating Procedure
Safe Operating Procedure (Revised 3/14) UNDERGROUND STORAGE TANKS SUMMARY OF REGULATORY REQUIREMENTS Underground storage tanks (UST) are defined as tanks containing petroleum or other regulated substances
More informationTitle: Jet Engine Test Cell
Environmental Standard Operating Procedure Originating Office: Revision: Prepared By: Approved By: MCAS Miramar Environmental Original Environmental Management Department William Moog Management Department
More informationJohn Benson David Hanny Barton & Loguidice, P.C.
John Benson David Hanny Barton & Loguidice, P.C. Environmental Regulations: An Alphabet Soup AAI UIC RCRA SPCC SPDES RMP CERCLA PBS CBS CAA CWA SPILLS DEC EPA OSHA Outline Regulatory Programs Lessons
More informationRULE 448 GASOLINE TRANSFER INTO STATIONARY STORAGE CONTAINERS Adopted (Amended , , , , , ) INDEX
RULE 448 GASOLINE TRANSFER INTO STATIONARY STORAGE CONTAINERS Adopted 2-5-75 (Amended 9-15-75, 8-3-77, 9-2-80, 12-17-91, 2-2-95, 02-26-09) INDEX 100 GENERAL 101 PURPOSE 102 APPLICABILITY 110 EXEMPTION:
More informationSyracuse University Petroleum Bulk Storage Tank Program Manual
Syracuse University Petroleum Bulk Storage Tank Program Manual August 23, 2017 Prepared by: Syracuse University Environmental Health & Safety Services Division of Campus Safety and Emergency Services 029
More informationThe Implementation of a Storage Facility Inspection Program. Presented By: John R. Rueckel PCA Engineering, Inc.
The Implementation of a Storage Facility Inspection Program Presented By: John R. Rueckel PCA Engineering, Inc. Storage Facility Inspection Why implement an inspection program? Regulatory Requirements
More informationSECTION FUEL-OIL DISTRIBUTION (APPLIES TO FUEL TANKS FOR GENERATORS)
SECTION 02554 - FUEL-OIL DISTRIBUTION (APPLIES TO FUEL TANKS FOR GENERATORS) 1.1 SUMMARY A. Storage tanks, fuel oil, tank accessories, piping, valves, and specialties for fuel-oil distribution inside and
More informationUnderstanding the Colorado Annual Compliance Package. William Holman & Robert Schlegel Inspectors Division of Oil and Public Safety
Understanding the Colorado Annual Compliance Package William Holman & Robert Schlegel Inspectors Division of Oil and Public Safety Overview Required Documentation: UST / AST Annual Compliance Package Release
More information6/15/2010. Environmental Auditing. Who Sponsors the Audits? Auditing Rationale. Birdsall Services Group (BSG-PMK) Rule of Self-Insured
Environmental Auditing Staying in Compliance with Environmental Regulations and Reducing Risk of Environmental Loss Who Sponsors the Audits? The Environmental Joint Insurance Fund (EJIF) is a public, non-profit
More informationSouth Tacoma Groundwater Protection District Spill Prevention and Response Plan
Name of Business Address Facility Phone ( ) - Types of Work or Hazardous Substances Used This spill plan is designed to handle the requirements for this system and associated hazardous substances. Update
More informationES Fueling Aircraft, Vehicles, and Auxiliary Equipment Document Identification Number
ES-301-1.01 Fueling Aircraft, Vehicles, and Auxiliary Equipment Document Identification Number ES-301-1.01 Document Owner: John Hambright 1) Activity Description: Fueling Aircraft, Vehicles, and Auxiliary
More informationSPILL PREVENTION, CONTROL, AND COUNTERMEASURE PLAN
411 B.H. Geothert Parkway 37388 SPILL PREVENTION, CONTROL, AND COUNTERMEASURE PLAN Prepared for: 411 B.H. Geothert Parkway 37388 Prepared by: 220 Athens Way, Suite 410 Nashville, Tennessee 37228 615.255.9300/1.800.588.7962
More information401 KAR 42:020. UST systems: design, construction, installation, and registration.
401 KAR 42:020. UST systems: design, construction, installation, and registration. RELATES TO: KRS 224.01, 224.10, 224.60, Chapter 322, Chapter 322A, 40 C.F.R. Part 280 Subpart B 42 U.S.C. 6991c, 6991e,
More informationLorri Grainawi Steel Tank Institute. PA NISTM April 25, 2013 Harrisburg, PA
Lorri Grainawi Steel Tank Institute PA NISTM April 25, 2013 Harrisburg, PA PEI/RP1200-12 ------------------------------------------------------ 1. Introduction 2. Definitions 3. Safety 4. Tank Secondary
More informationSPILL PREVENTION CONTROL AND COUNTERMEASURE PLAN (SPCC)
YUKON-KOYUKUK SCHOOL DISTRICT ALLAKAKET SCHOOL FUEL STORAGE FACILITY ALLAKAKET, ALASKA OIL SPILL PREVENTION AND RESPONSE PLANS U.S. ENVIRONMENTAL PROTECTION AGENCY SPILL PREVENTION CONTROL AND COUNTERMEASURE
More informationSPILL PREVENTION CONTROL AND COUNTERMEASURE PLAN (SPCC) OPERATIONS MANUAL
YUKON-KOYUKUK SCHOOL DISTRICT ANDREW K. DEMOSKI SCHOOL FUEL STORAGE FACILITY NULATO, ALASKA OIL SPILL PREVENTION AND RESPONSE PLANS U.S. ENVIRONMENTAL PROTECTION AGENCY SPILL PREVENTION CONTROL AND COUNTERMEASURE
More information(Please type or use black ink)
(Please type or use black ink) PNIPUG ALABAMA DEPARTMENT OF ENVIRONMENTAL MANAGEMENT NOTICE OF PROPOSED UST NEW INSTALLATION OR UPGRADE (Use a separate form for each separate place of operation) Date of
More informationState of California AIR RESOURCES BOARD EXECUTIVE ORDER VR-302-B
State of California AIR RESOURCES BOARD EXECUTIVE ORDER VR-302-B Standing Loss Control Vapor Recovery System for New Installations of Aboveground Storage Tanks WHEREAS, the California Air Resources Board
More informationABOVEGROUND STORAGE TANK REGULATIONS -ADAM WILSON SLS LAND & ENERGY DEVELOPMENT
ABOVEGROUND STORAGE TANK REGULATIONS -ADAM WILSON SLS LAND & ENERGY DEVELOPMENT WHAT IS AN AST? VOLUME GREATER THAN 1320 GALLONS CONTENTS ARE LIQUID AT STANDARD TEMPERATURE AND PRESSURE GREATER THAN 90%
More informationAir Permitting: Municipal Facilities with Emergency Generators
Air Permitting: Municipal Facilities with Emergency Generators Sam Cotter, P.E. sam.cotter@cardinalengineers.com 7060 S. Yale, Suite 603 Tulsa, OK 74136 Introduction Generators are located at our utility
More informationDRIVER QUALIFICATION FILE CHECKLIST
DRIVER QUALIFICATION FILE CHECKLIST 1. DRIVER APPLICATION FOR EMPLOYMENT 391.21 2. INQUIRY TO PREVIOUS EMPLOYERS (3 YEARS) 391.23(a)(2) & (c) 3. INQUIRY TO STATE AGENCIES 391.23(a)(1) & (b) 4. MEDICAL
More informationFACTS ABOUT: MARYLAND CONTAINMENT SUMP TESTING PROTOCOL WHO CAN PERFORM THE TEST
FACTS ABOUT: MARYLAND CONTAINMENT SUMP TESTING PROTOCOL On January 26, 2005, the Maryland Department of the Environment (the Department) implemented, in the Code of Maryland Regulations (COMAR) 26.10,
More informationEXPIRATION DATE: (FOR RENEWAL, SEE 49 CFR )
East Building, PHH-30 1200 New Jersey Avenue S.E. U.S. Department of Transportation Washington, D.C. 20590 Pipeline and Hazardous Materials Safety Administration DOT-SP 16365 (FIRST REVISION) EXPIRATION
More informationCompliance Strategies and Benefits
Compliance Strategies and Benefits NISTM St. Louis Conference October 17, 2012 Brad Walls Director, Central Division Welcome Agenda Introduction Proposed Revisions to Federal Regulations Best Practices
More informationPEI/RP Recommended Practices for Installation of Bulk Storage Plants
PEI/RP800-08 Recommended Practices for Installation of Bulk Storage Plants Recommended Practices for Installation of Bulk Storage Plants CONTENTS Foreword...iii. SECTIONS 1. Introduction Page 1.1 Background...1
More informationE. Augusta, Spokane, WA (509) E. Augusta, Spokane, WA (509)
Notice of Construction (NOC) Approval Issued in accordance with: Chapter 70.94 RCW, SRCAA Regulation I, Article V, Chapter 173-400 WAC, and Chapter 173-491 WAC 3104 3104 E. Augusta, Spokane, WA 99207 (509)
More informationReadopt with amendment Env-Wm , eff (doc. #8359), to read as follows:
FP 2008-199 Adopted 01/20/09 1 Readopt with amendment Env-Wm 1402.01, eff. 5-28-05 (doc. #8359), to read as follows: Env-Wm 1402.01 Purpose. The purpose of these rules is to minimize contamination of the
More informationIC Chapter 5. Motor Vehicle Emission Control
IC 13-17-5 Chapter 5. Motor Vehicle Emission Control IC 13-17-5-1 Rules Sec. 1. The board may adopt rules for the control of emissions from vehicles. However, the board must, before adopting the rules,
More informationElectrical Power Generator Use and Procurement Guidance
Electrical Power Generator Use and Procurement Guidance For compliance with applicable air emission control regulations December 2016 Prepared by: Syracuse University Environmental Health & Safety Services
More informationForm UST FP-290 Notification for Underground Storage Tanks Regulated Under 527 CMR 9.00
Massachusetts Department of Environmental Protection Underground Storage Tank Program Form UST FP-290 Notification for Underground Storage Tanks Regulated Under 527 CMR 9.00 Forward completed form to:
More informationMark S. Morgan, Regulatory Counsel
SUBJECT: ISSUE: PMAA CONTACT: EPA UST Regulations Final UST Rules Mark S. Morgan, Regulatory Counsel mmorgan@pmaa.org DATE: November 16, 2015 U.S. EPA FINAL UNDERGROUND STORAGE TANK REQUIREMENTS: I. BACKGROUND
More informationEJIF Municipal Inspection Checklist
91 Fulton Street, Boonton, NJ 07005 Tel: (973) 334-0003, Fax: (973) 334-0928 Inspection Date: Municipality Name: Administrator/Clerk: EJIF Municipal Inspection Checklist Primary DPW Contact: Title: DPW
More informationSteel Tank Institute Updates 8 th Missouri Storage Tank Conference August 30, 2018 Blue Springs
Steel Tank Institute Updates 8 th Missouri Storage Tank Conference August 30, 2018 Blue Springs Wayne Geyer and Steve Pollock Steel Tank Institute/Steel Plate Fabricators Association STI/SPFA The Trade
More informationOperational Compliance Closure/Release Response/Corrective Action at Underground Storage Tank Facilities
Connecticut Department of Energy and Environmental Protection Operational Compliance Closure/Release Response/Corrective Action at Underground Storage Tank Facilities May 15, 2015 Peter Zack, Assistant
More informationREGULATION II PROHIBITIONS. 1.1 Purpose To limit the emission of gasoline vapor into the atmosphere during the filling of motor vehicle fuel tanks.
Rule 215 Phase II Vapor Recovery System Requirements Part 1.0 General 1.1 Purpose To limit the emission of gasoline vapor into the atmosphere during the filling of motor vehicle fuel tanks. 1.2 Applicability
More informationUS oil production hits 15-year high: DEC 04, 2012
Setting a New Standard!! US oil production hits 15-year high: DEC 04, 2012 Domestic crude oil production in September hit the highest monthly output since 1998, according to the U.S. Energy Information
More informationCONTENTS. Foreword...iii. 1. Introduction...1
Installation of Aboveground Storage Systems for Motor-Vehicle Fueling CONTENTS Foreword...iii SECTIONS 1. Introduction...1 1.1 Background...1 1.2 Purpose...1 1.3 Scope...1 1.4 Source...1 1.5 Use of PEI/RP100...1
More informationBUREAU OF UNDERGROUND STORAGE TANK REGULATIONS RELEASE PREVENTION SECTION
BUREAU OF UNDERGROUND STORAGE TANK REGULATIONS RELEASE PREVENTION SECTION Page 3 Federal law requires the Division of State Fire Marshal, Bureau of Underground Storage Tank Regulations (BUSTR) to inspect
More informationRULE 449 TRANSFER OF GASOLINE INTO VEHICLE FUEL TANKS
RULE 449 TRANSFER OF GASOLINE INTO VEHICLE FUEL TANKS Adopted 2-5-75 (Amended 9-15-75, 6-1-76, 8-3-77, 9-29-87, 12-17-91, 2-2-95, 4-3-97, 09-26-02, 02-26-09) INDEX 100 GENERAL 101 PURPOSE 102 APPLICABILITY
More informationEJIF Municipal Inspection Checklist
Inspection Date: EJIF Municipal Inspection Checklist Birdsall Services Group/PMK Group 65 Jackson Drive Cranford, New Jersey 07016 Phone: (908) 497-8900 Fax: (908) 497-8942 Municipality Name: Administrator/Clerk:
More informationSummaries for Gasoline Distribution Facilities and Gasoline Dispensing Facilities 40 CFR 63 subpart BBBBBB and 40 CFR 63 subpart CCCCCC
2011 Summaries for Gasoline Distribution Facilities and Gasoline Dispensing Facilities 40 CFR 63 subpart BBBBBB and 40 CFR 63 subpart CCCCCC Ohio EPA, Division of Air Pollution Control 1/1/2011 Page 2
More informationDepartment of the Environment. Moving Away From Stage II Vapor Recovery
Department of the Environment Moving Away From Stage II Vapor Recovery 2013 Stage II Regulations Stakeholder Meeting November 12, 2013 Topics Covered Background The technical analyses What does it tell
More informationWayne Geyer Steel Tank Institute NISTM 3 rd Annual UST Conference Alexandria, VA May 25, 2016
Wayne Geyer Steel Tank Institute NISTM 3 rd Annual UST Conference Alexandria, VA May 25, 2016 STI est. 1916, SPFA est. 1935 Anniversary activities New, modern logo 100 th Anniversary Webpage featuring
More informationOverview of an Underground Storage Tank Inspection
Overview of an Underground Storage Tank Inspection PURPOSE OF INSPECTION Protect drinking water, lakes, streams, etc. Education. Protect property value. TECHNICAL ASSISTANCE INSPECTIONS Technical Assistance
More informationCOMMERCIAL DRIVER APPLICATION
Date: COMMERCIAL DRIVER APPLICATION Professional Transportation Services, Inc PO Box 2368 541-826-7645 tel 541-826-8921 fax Name: First Middle Last Address Home telephone: City State Zip Cellular telephone:
More informationSpill Prevention Report Lift Station 1A. Prepared By:
Spill Prevention Report Lift Station 1A Prepared By: Contents 1) Purpose... 3 2) General Information... 3 3) Report Certification and Approval... 3 4) Facility Description... 4 5) Summary and Leaks, Spills
More informationPURPOSE RESPONSIBILITY
PAGE 1 OF 6 PURPOSE This Standard Operating Procedure (SOP) provides guidance and methods for Underground Storage Tank (UST) inventory control at Massachusetts Department of Transportation, Highway Division
More informationField-Erected AST Secondary Containment Options. Mott-Smith Consulting Group, LLC
Field-Erected AST Secondary Containment Options Mott-Smith Consulting Group, LLC Marshall T. Mott-Smith, President Mott-Smith Consulting Group, LLC National Technical Expert and Regulatory Liaison, AET
More informationUnderground Storage Tank Certification Examinations. Presentation to ASTSWMO November 27, 2007 UST SYSTEM OPERATOR CERTIFICATION
INTERNATIONAL CODE COUNCIL Underground Storage Tank Certification Examinations Presentation to ASTSWMO November 27, 2007 UST SYSTEM OPERATOR CERTIFICATION Doug Hatch Test Developer, Program Manager International
More informationPetroleum Storage Tank Release Detection and Inventory Control
TCEQ REGULATORY GUIDANCE Small Business and Environmental Assistance Division RG-475g August 2009 Petroleum Storage Tank Release Detection and Inventory Control Methods for underground storage tanks and
More informationSAN JOAQUIN VALLEY UNIFIED AIR POLLUTION CONTROL DISTRICT DRAFT STAFF REPORT
DRAFT STAFF REPORT Draft Amendments to Rule 4621 (Gasoline Transfer into Stationary Storage Containers, Delivery Vessels, and Bulk Plants) and Rule 4622 (Gasoline Transfer into Motor Vehicle Fuel Tanks)
More informationEnvironmental Standard Operating Procedure (ESOP)
Environmental Standard Operating Procedure (ESOP) Originating Office: Natural Resources Environmental Affairs (NREA) Office File Name: AST-ESOP Revision: 24 January 2017 Prepared By: NREA Subject Matter
More informationRemoval of Underground Storage Tanks (UST) Encountered during Construction
Removal of Underground Storage Tanks (UST) Encountered during Construction Technical Guide Environmental Affairs Division TxDOT Environmental Affairs Division Release Date: 2/2014 510.06.GUI Version 1
More informationCode Requirements for ASTs at Motor Vehicle-Dispensing Stations
Code Requirements for ASTs at Motor Vehicle-Dispensing Stations This table compares aboveground storage tank requirements in the 2015 edition of, to the 2015 International Fire Code (). Please note that
More informationPreventing Leaks and Spills at Service Stations. A Guide for Facilities
Preventing Leaks and Spills at Service Stations A Guide for Facilities United States Environmental Protection Agency Pacific Southwest/Region 9 EPA-909-K-03-001/October 2003 Contents Underground Storage
More informationSan Joaquin Valley Air Pollution Control District Vapor Recovery Requirements for Permitted Agricultural Gasoline Storage and Dispensing Operations
San Joaquin Valley Air Pollution Control District Vapor Recovery Requirements for Permitted Agricultural Gasoline Storage and Dispensing Operations The purpose of this document is to coalesce the various
More informationCONTRACTOR S SELF-INSPECTION CHECKLIST for UST INSTALLATION REPLACEMENT UPGRADE RETROFIT REPAIR
Environmental Health - UST Program CONTRACTOR S SELF-INSPECTION CHECKLIST for UST INSTALLATION REPLACEMENT UPGRADE RETROFIT REPAIR As part of our inter-local contract with the Nevada Division of Environmental
More informationBoard Administration and Regulatory Coordination Unit. Division 3. Air Resources Board
2423. Exhaust Emission Standards and Test Procedures--Heavy-Duty Off-Road Diesel Cycle Engines. (a) This section shall be applicable to new heavy-duty off-road compression-ignition engines, produced on
More informationOREGON DEPARTMENT OF TRANSPORTATION SPILL PREVENTION, CONTROL, AND COUNTERMEASURE PLAN
OREGON DEPARTMENT OF TRANSPORTATION SPILL PREVENTION, CONTROL, AND COUNTERMEASURE PLAN for the MADRAS MAINTENANCE YARD 201 NW Cherry Lane Madras, OR 97741 Region: 4 District: 10 Property EA: F41602 prepared
More informationOverview of Revisions to the Federal Underground Storage Tank (UST) Regulations. Storage Tank Advisory Committee Harrisburg, PA September 1, 2015
Overview of Revisions to the Federal Underground Storage Tank (UST) Regulations Storage Tank Advisory Committee Harrisburg, PA September 1, 2015 Why is EPA making changes to the UST regulations? The Energy
More informationPowered Industrial Truck Safety Program
Powered Industrial Truck Safety Program 0 TABLE OF CONTENTS Forklift Safety Program 1.0 Overview.. 2 2.0 Purpose....2 3.0 Procedures..2 4.0 Responsibilities. 4 5.0 Training Requirements......5 Appendix
More informationUnderground Storage Tank Guidance for Commercial Building Inspectors
National Association of Commercial Building Inspectors & Thermographers Contributor/Author: John Bowman The content provided in these white papers is intended solely for general information purposes only,
More informationNYSDEC PBS REGULATIONS Heating Oil Tanks
1 NYSDEC PBS REGULATIONS Heating Oil Tanks Central Office/Region 2 Division of Environmental Remediation Bulk Storage Compliance Program NISTM 2017 New York Storage Tank Conference Saint Francis College,
More informationAboveground Tank Equipment. Presenter: Steven Allwein Northeast Regional Sales Manager Morrison Bros. Co.
Aboveground Tank Equipment Presenter: Steven Allwein Northeast Regional Sales Manager Morrison Bros. Co. HISTORY Morrison Bros. Co. Then Founded in 1855 Located in Dubuque, Iowa Originally a boiler manufacturer
More informationFMCSA Medical Fraud Process. Eric Adair FMCSA
FMCSA Medical Fraud Process Eric Adair FMCSA Agenda: Medical Examiners Registry (brief history) Evolution of Fraud Cases Fraud Identified SDLA Involvement in the Fraud Process Closing the Case Medical
More informationContainer Management ASTSWMO. Conference & Training
Container Management ASTSWMO 2010 Hazardous Waste Managers Conference & Training June 30,2010 Overview Purpose Background Existing Standards d Common violations Closed Container Guidance Container Guidance
More informationDisclaimer - Appendix E
Disclaimer - Appendix E The sample Spill Prevention, Control and in Appendix E is intended to provide examples and illustrations of how a production facility could address a variety of scenarios in its
More informationSPILL PREVENTION CONTROL AND COUNTERMEASURE PLAN (SPCC) OPERATIONS MANUAL
YUKON-KOYUKUK SCHOOL DISTRICT JIMMY HUNTINGTON SCHOOL FUEL STORAGE FACILITY HUSLIA, ALASKA OIL SPILL PREVENTION AND RESPONSE PLANS U.S. ENVIRONMENTAL PROTECTION AGENCY SPILL PREVENTION CONTROL AND COUNTERMEASURE
More informationOIL SPILL PREVENTION, CONTROL, AND COUNTERMEASURE PLAN. St. Lawrence University Canton, New York. January 2007
OIL SPILL PREVENTION, CONTROL, AND COUNTERMEASURE PLAN St. Lawrence University Canton, New York January 2007 Revised April 30, 2008 Revised December 1, 2008 Revised December 1, 2009 TABLE OF CONTENTS SECTION
More informationUST Compliance Review
UST Compliance Review Certificate Dispenser Card Reader Annular probe Spill bucket Fill pipe Tank sump Veeder Root Line Files Tank probe Dispenser sump Note: pumps are either submersible (in tank) or suction
More informationSPILL PREVENTION CONTROL AND COUNTERMEASURE
SPILL PREVENTION CONTROL AND COUNTERMEASURE Knife River Asphalt Plant 1 Portable Facility Date of Last Plan Amendment or Technical Revision P.E. Certification: Date of Last Administrative Revision: July
More informationUNDERGROUND STORAGE TANK PROVISIONS IN SENATE BILL NO. 612 (STATS. 2015, CH 452) FOR TANKS IN UNDERGROUND AREAS
December 4, 2015 To: Unified Program Agencies and Other Interested Parties UNDERGROUND STORAGE TANK PROVISIONS IN SENATE BILL. 612 (STATS. 2015, CH 452) FOR TANKS IN UNDERGROUND AREAS On October 2, 2015,
More information