1 0402-MID Wayne Helix Fuel dispenser TM and self-service devices Issued to Wayne Fueling Systems Sweden AB, P O Box 50559, SE Malmö, Sweden. Conformity assessment procedure used is module B+D. Module B concerns conformity to type (0402-MID ) and module D concerns production. All production sites holding a module D certificate with reference to 0402-MID are approved without being listed in 0402-MID In respect of (type of instrument) A family of Wayne Helix 1000 Fuel dispenser, Wayne Helix 2000 Fuel dispenser, Wayne Helix 4000 Fuel dispenser, Wayne Helix 5000 Fuel dispenser, Wayne Helix 6000 Fuel dispenser, for petrol, kerosene, diesel, ethanol, FAME/RME, HVO fuel, DEF (Diesel Exhaust Fluid) or LPG, including ATC conversion device (optional). Self-service device including outdoor payment terminal Wayne ixpay TM secure payment platform (optional), HeliX Pay Freestanding (optional) and forecourt controller and Point-of-sale system, Wayne Fusion forecourt system (optional) or as listed in the appendix, chapter 1. The instrument (measuring system) includes at minimum a fuel dispenser (stand alone) and at maximum also one or more outdoor payment terminals ixpay TM secure payment platform (Evaluation Certificate, EC, and ) and a forecourt controller and Point-of-sale system, Wayne Fusion forecourt system (EC and EC ) or as listed in the appendix, chapter 1. In accordance with STAFS 2016:1 Measuring Instruments Regulations STAFS 2016:6 Regulations and Guidelines concerning Measuring Systems for the Continuous and Dynamic Measurement of Quantities other than Water; implementing in the NB s country law the Directive 2014/32/EU of 26 February 2014 on measuring instruments (MID). Applicable essential requirements of directive 2014/32/EU - Annex I, Essential requirements - Annex VII (MI-005) Measuring systems for the continuous and dynamic measurement of quantities of liquids other than water Harmonised standards and normative documents used Applicable parts of the following normative documents referred to in the Official Journal of the European Union 2006/C 269/01 and 2011/C 33/01 (for 2004/22/EU): - OIML R 117 Edition 1995 (E), Measuring systems for liquids other than water - OIML R Edition 2007 (E), Dynamic measuring systems for liquids other than water Further applied documents - WELMEC 7.2, Software Guide (Issue 5) Rated operating conditions Measurand: volume of fuel Mechanic environment class: M1 Accuracy class: 0,5 and 1,0 (LPG) Climatic environment class: -40 to +55 C Measurement range: 0,2 200 l/min Electromagnetic environment class: E1 The certificate, including appendices consists of 40 pages where this is page 1. Accred. no Certification of Products ISO/IEC 17065

2 0402-MID Wayne Helix Fuel dispenser TM and self-service devices Miscellaneous Valid until December 6, This certificate is the 15 th, extended, edition, and replaces earlier issues. The first edition was issued on December 6, The principal characteristics, approval conditions are set out in the appendix hereto, which forms part of the approval document. All the plans, schematic diagrams and documentations are recorded under reference files PX The evaluation report PX25468A has been issued in accordance with Directive 2014/32/EU Annex B paragraph Certification - Notified Body No Martin Tillander Product Certification Manager Kerstin Mattiasson Certification Officer The certificate, including appendices consists of 40 pages where this is page 2. Accred. no Certification of Products ISO/IEC 17065

3 The instruments / measuring systems must correspond with the following specifications: 1 Design of the instrument The instrument (measuring system) includes at minimum a fuel dispenser (stand alone). The fuel dispenser (except for DEF) may (optional) display volume at base condition (15 C). The fuel dispenser may (optional) also be part of any self-service arrangement under conditions that the connected self-service device/devices: has any Part Certificate issued by a test institute that also can act as a notified body under module B of MID for measuring instrument for liquids other than water (MI-005) or is covered by an Evaluation Certificate listed in table 1 and the self-service arrangement fulfils the communication requirements in chapter 3 of this certificate. Trade mark Evaluation Certificate Additional information referred to in the EC Wayne ixpay TM secure payment SP platform Wayne ixpay TM secure payment SP platform and Freestanding Gilbarco Autotank NC3/NP3 SP Wayne Fusion forecourt system. SP Forecourt controller and Point-of-sale system Wayne Fusion forecourt system. SP Forecourt controller and Point-of-sale system Wayne Nucleus 9. Forecourt SP controller and Point-of-sale system S&B TMS30. Self-service device NMi TC7596 Documentation folder TC (via the contact form on Bachmann.com) Tokheim FuelPOS. Self-service device NMi TC7346 Documentation folder TC and TC (via the contact form on RAP Sustain. Self-service device NMi TC7657 Documentation folder TC SYST- 1 to 11 (via liquid@nmi.nl) LAFON ELYS. Self service device LNE Gilbarco Veeder-Root, Passport Europe Nordic Card CRIP for GS/SK, Nordic Card stand alone OPT, Nordic Pay OPT, CRIND SQUARE M3 Q500T, Flex Pay B2B M3, Flex Pay SPOT OPT M7 Orpak, Systor POS & OrPt OPT NMi TC7581 Inspecta, FIT.10.A.01 NMO, GB-1381 Table 1 Documentation folder TC7581-2, number 7481/1-01 (via flr.reg@gilbarco.com) The certificate, including appendices consists of 40 pages where this is page 3.

4 These self-service arrangement are then part of the measuring system and this EC-type examination certificate. The self-service modes (optional) includes attended pre-payment, attended post-payment including sale stacking, unattended pre-payment and unattended delayed-payment, for an interruptible system and direct sales. This chapter describes the fuel dispenser. For other parts of a self-service arrangements see above. 1.1 Construction Product names (see pictures 1-9): Wayne Helix 1000 Fuel dispenser Wayne Helix 2000 Fuel dispenser Wayne Helix 4000 Fuel dispenser Wayne Helix 5000 Fuel dispenser Wayne Helix 6000 Fuel dispenser Product designation: The certificate, including appendices consists of 40 pages where this is page 4.

5 A and B side is recognized by removing one of the doors from the hydraulic cabinet and look at the sheet metal support for pumping units (suction-dispensers) or meters (remote-dispensers). There is the letter A or B punched in to the sheet metal as can be seen in the pictures below. The certificate, including appendices consists of 40 pages where this is page 5.

6 Measuring system (fuel dispenser) description A complete measuring system consists of one electronic module and one to six hydraulic modules. The hydraulic moduls are placed in one or two cabinets (B2B). One electronic module can serve both cabinets, for example a combination of LPG and petrol. If one pump and air separator is serving more than one nozzle simultaneously the total maximum flowrate through these nozzles is limited by the air separator (90 l/min per air separator) and the volume sensor (according to Volume sensor flowrate range under Technical data, page 19). For higher flowrate another hydraulic module have to serve the same nozzle. For further information see block diagram, page 7. Module function description For further information about components included see page Electronic module function (igem) is an electronic subsystem and it consists mainly of: calculator, indicating device, and keyboard with preset. This module can handle up to 6 motors, 6 pulse transmitters (each handling a single equipped or a duplex volume sensor), 12 nozzles, 14 solenoid valves and in case of ATC one temperature compensation module. The electronic module is able to serve up to four customers at a time (called 4 User). Hydraulic function modules Measurement transducer function is a hydraulic subsystem and it consists mainly of: volume sensor (single equipped side A, single equipped side B or duplex) and pulse transmitter. In case of ATC (automatic temperature compensation) each volume sensor (imeter, imeter2, Xflo TM ) is equipped with a temperature sensor, all connected to one temperature compensation module. Pump and air separator function is a hydraulic subsystem and it consists mainly of: Compact Pumping Unit (CPU) including air separator, motor and non-return valve and for LPG a differential valve. Regulation function is a hydraulic subsystem and it consists mainly of: solenoid valves for flow rate regulation, blending and on/off. Delivery function is a hydraulic subsystem and it consists mainly of: hoses, nozzles and nozzle switch, this includes also satellite function. Central pump function is a hydraulic subsystem and it consists mainly of: delivery of air free liquid according to OIML R117, item and security valve. If the measuring system is equipped with a central pump (an additional R ) an external (central) pump is used instead of an internal pump. The external system must comply with OIML 117, item (i.e. it shall be equipped with an arrangement that prevents air to come into the system). The same applies to additive injection. The certificate, including appendices consists of 40 pages where this is page 6.

7 Liquid quality 2 Liquid quality 1 EU-type examination Certificate During verification it shall be possible to verify each volume sensor separately. Block diagram describing permitted ways, and some restrictions, to produce one delivery product for one customer. Each such configuration shall be a subset of the diagram. To produce multiple delivery products for a customer the block diagram is used several times. max 2 M R M D P/A R P/A R M R R M D P/A R P/A R M R P/A = pressurizing and air separation CPU, (dispenser bottom,) cover, motor, non-return valve (and security valve) M = measuring volume sensor and pulse transmitter R = regulating solenoid valve D = delivering hose, nozzle and nozzle switch The certificate, including appendices consists of 40 pages where this is page 7.

8 Picture 1: Wayne Helix 5000 Fuel dispenser Picture 2: Wayne Helix 5000 Fuel dispenser with Wayne ixpay TM secure payment platform (EC ) Picture 3: Wayne Helix 2000 Fuel dispenser Picture 4: Wayne Helix 1000 Fuel dispenser The certificate, including appendices consists of 40 pages where this is page 8.

9 Picture 5: Wayne Helix 6000 Fuel dispenser Picture 6: Wayne Helix 6000 Fuel dispenser with Wayne ixpay TM secure payment platform (EC ) Picture 7: Wayne Helix 6000 Fuel dispenser B2B Picture 8: Wayne Helix 1000 Fuel dispenser LPG The certificate, including appendices consists of 40 pages where this is page 9.

10 Picture 9: Wayne Helix 6000 Fuel dispenser Metallic head The certificate, including appendices consists of 40 pages where this is page 10.

11 1.2 Components included for hydraulic function modules When numbers are stated in the list below, these numbers are valid for all measuring systems. When numbers are not stated in the list below then the numbers are limited by the measuring system description and the electronic module function on page 4-6. Measurement transducer function Volume sensor (petrol, petrol/ethanol mixtures, kerosene, diesel or diesel/fame/rme mixtures) Volume sensor (DEF) Volume sensor (LPG) (including differential valve) Pulse transmitter Wayne imeter Duplex (DM2-2) or Wayne imeter Single equipped side A (DM2-1) or Wayne imeter Single equipped side B (DM2-1) or Wayne imeter2 Duplex (DM2-2) or Wayne imeter2 Single equipped side A (DM2-1) or Wayne imeter2 Single equipped side B (DM2-1) or Wayne Xflo TM Duplex (magenta or silver id label) or Wayne Xflo TM Single sided A (yellow id label) or Wayne Xflo TM Single sided B (cyan id label) Wayne imeter DM2-X UREA Petrolmeccanica LPG6000 MA (with mechanical adjustment) Petrolmeccanica LPG6000 WA (without mechanical adjustment) Tokheim GPL700 Wayne PNo i-meter i-meter2 Xflo TM LPG WM NFC NFC NFC WM NFC NFC NFC WM NFC NFC WM FC WM FCI WM FCI WM FCI Board temperature module, phase 2, 0-1 pc**** FC=Flow Compensating, FCI = Flow Compensating Individual(XWIP), NFC= Not Flow Compensating (WIP) Wayne WM X Software Board temperature module, 0-1 pc**** W&M checksum EB6A, or 7EA9 Temperature sensor, 0-10 pcs**** Pump and air separator function, not LPG Compact Pumping Unit (CPU) * Wayne WM Wayne i-meter i-meter2 Xflo TM WM D, H D, H WM P, K, E P, K, E WM P, K, D, H, E, F P, K, D,H, E, F P, K, D,H, E, F WM WM P = petrol, K = kerosene, D = diesel, E = ethanol, F=FAME/RME, H=HVO P, K, D,H, E, 40 l/min P, K, D,H, 70 l/min The certificate, including appendices consists of 40 pages where this is page 11.

12 Cover (between CPU and meter) ** Motor **, one per CPU Inlet suction check valve ** Additive liquid injection tank gauge, 0-1pc Wayne or Wayne WM or Wayne WM or Wayne WM or Wayne WM or Wayne WM X or Wayne WM X Elnor, 0,75 kw, 3-phase 400 V, 1400 rpm or Elnor, 0,75 kw, 3-phase 230 V, 1400 rpm or Elnor, 0,75 kw, 1-phase 230 V, 1400 rpm or Elnor, 1,1 kw, 3-phase 400 V, 1400 rpm or Elnor, 1,1 kw, 3-phase 230 V, 1400 rpm or Elnor, 1,1 kw, 1-phase 230 V, 1400 rpm Wayne WM X Wayne (START ITALIANA S.r.l. (ProGauge)) WT Pump and air separator function, LPG Remote pump, submerged Gas separator, non return valve and strainer Petrolmeccanica LP0735R01 (WM058684) Vapour return line from gas separator and differential valve at volume sensor or Tokheim GPL Gas separator : ; LPG Diff valve : ; non return valve : The certificate, including appendices consists of 40 pages where this is page 12.

13 Regulating function, solenoid valve, not LPG NEW ASC0 code Cat no. Voltage Wayne code (Datasheet in paranthese) JV /DC WM (WU007252) JV /DC WM (WU007252) JV /DC WM (WU007252) Wayne designation SOLENOID VALVE, PROPORTIONAL, SINGLE IECEX, ALU BODY SOLENOID VALVE, PROPORTIONAL, SINGLE IECEX, ALU BODY, INMETRO, PRODUCTION BRAZIL SOLENOID VALVE, PROPORTIONAL, SINGLE IECEX, COMPCOTE ALU BODY JV /DC WM (WU007253) SOLENOID VALVE, ON/OFF, SINGLE IECEX, ALU BODY JV /DC WM (WU007254) JV /DC WM (WU007255) SOLENOID VALVE, PROPORTIONAL, SINGLE IECEX, BRASS BODY SOLENOID VALVE, PROPORTIONAL, DUPLEX, SINGLE EQUIPPED RIGHT, IECEX, BRASS BODY JV /DC WM (WU007256) SOLENOID VALVE, ON/OFF, DUPLEX IECEX, BRASS BODY JV /DC WM (WM045843) JV /DC WM (WM045843) JV /DC WM (WM045843) JV /DC WM (WM045843) JV JV /DC 24/DC WM (WM045843) WM (WM045843) JV /DC WM (WM045843) SOLENOID VALVE, PROPORTIONAL, SINGLE IECEX, ALU BODY, CABLE LENGTH 3000 mm SOLENOID VALVE, PROPORTIONAL, SINGLE IECEX, ALU BODY, INMETRO, PRODUCTION BRAZIL SOLENOID VALVE, PROPORTIONAL, SINGLE IECEX, COMPCOTE ALU BODY SOLENOID VALVE, PROPORTIONAL, SINGLE IECEX, COMPCOTE ALU BODY, CABLE LENGTH 1750 mm SOLENOID VALVE, PROPORTIONAL, SINGLE IECEX, COMPCOTE ALU BODY, CABLE LENGTH 1750 mm SOLENOID VALVE, PROPORTIONAL, SINGLE IECEX AND INMETRO, ALU BODY, 3 M CABLE SOLENOID VALVE, PROPORTIONAL, SINGLE IECEX, COMPCOTE ALU BODY, 5 M CABLE JV /DC WM (WM045844) SOLENOID VALVE, ON/OFF, SINGLE IECEX, ALU BODY JV /DC WM (WM045846) JV /DC WM (WM045847) SOLENOID VALVE, PROPORTIONAL, DUPLEX IECEX, BRASS BODY SOLENOID VALVE, PROPORTIONAL, DUPLEX, SINGLE EQUIPPED RIGHT, IECEX, BRASS BODY JV /DC WM (WM045850) SOLENOID VALVE, ON/OFF, DUPLEX IECEX, BRASS BODY The certificate, including appendices consists of 40 pages where this is page 13.

14 Regulating function, LPG Differential valve (Included in volume sensor LPG6000. Separate after the volume sensor for GPL700.), liquid pressure at least 1 bar higher than vapour pressure Manometer, between volume sensor and differential valve Scale interval d 2 bar Delivery function Hose, 16 mm (5/8 ), max length 10 m Elaflex Conti-Slimline 16 Hose, 16 mm (5/8 ), max length 10 m Hose, 16 mm (5/8 ), max length 10 m Hose, 16 mm (5/8 ), max length 10 m Elaflex Conti-Slimline 16 BIO Elaflex Conti-Slimline 16 LT Goodyear EN 1360, type 3, 16 bar Hose, 19 mm (3/4 ), max length 10 m Goodyear Hardwall Petrol Hose B.S. 3395/1989 type 3 Hose, 21 mm (7/8 ), max length 10 m Elaflex Conti-Slimline 21 Hose, 21 mm (7/8 ), max length 6 m Hose, 21 mm (7/8 ), max length 10 m mmq = 5,0 l Hose, 21 mm (7/8 ), max length 10 m Hose, 21 mm (7/8 ), max length 10 m Hose, 21 mm (7/8 ), max length 6 m Hose, 21 mm (7/8 ), max length 10 m mmq = 5,0 l Hose, 25 mm (1 ), max length 6 m Hose, 25 mm (1 ), max length 10 m mmq = 5,0 l Hose, 25 mm (1 ), max length 10 m Hose, 32 mm (1 1 / 4 ), max length 7 m Elaflex HD 32 mmq = 5,0 l Hose, DEF, max length 6 m, mmq = 5,0 l Hose, LPG, max length 6 m, mmq = 5,0 l Hose, 25 mm (1 ), max length 40 m, mmq = 20 l, max flow rate >60 LPM Hose, 32 mm (1 1 / 4 ), max length 40 m, mmq = 20 l, max flow rate >60 LPM Elaflex Conti-Slimline 21 - COAX (vapour recovery) Elaflex Conti-Slimline 21 - COAX (vapour recovery) Elaflex Conti-Slimline 21 BIO Elaflex Conti-Slimline 21 LT Elaflex Conti-Slimline 21 LT (vapour recovery) Elaflex Conti-Slimline 21 LT (vapour recovery) Elaflex Conti-Slimline 25 LT Elaflex Conti-Slimline 25 LT Goodyear EN 1360, type 3, 16 bar Elaflex LPG ID=16, max working p=25 bar Elaflex LPG ID=13, Elaflex LPG ID=16 or Elaflex LPG ID=19, max working p=25 bar Elaflex HD 25 C winded on Reel Elaflex HD 32 C winded on Reel The certificate, including appendices consists of 40 pages where this is page 14.

15 Nozzle l/min Nozzle l/min, mmq = 5,0 l Nozzle 40 l/min, mmq = 5,0 l Nozzle l/min Nozzle l/min Nozzle, DEF Nozzle, DEF Nozzle, LPG Nozzle switch (Helix with nozzle inteface) Nozzle switch (Helix without nozzle inteface) Elaflex ZVA slimline or equivalent Elaflex ZVA slimline TMV DRIP-STOP or equivalent OPW ACN or AVN or equivalent Elaflex ZVA 25, 1 or equivalent Elaflex ZVA 32, 1 1 / 4 or equivalent Elaflex ZVA SS AdBlue or equivalent Elaflex ZVA AdBlue LV or equivalent Elaflex ZVG 2, Elaflex Gasguard LPG, Boessenkool LPG, OPW LPG or equivalent Hamlin type S-02-A or S-05-A or S-02-F or S-05-F or Secatec type MKF 19XSAKX or Secatec type MKF19XOAKX or Bartec or Bartec or Bartec Components included for electronic function Components included for electronic function, igem CPU-board,0, 1 or 2 (only for 4User) pc Software CPU board, 0 or 1 pc Software CPU board for dispensers with igem printer, 0 or 1 pc igem expansion board, 0-1 pc Nozzle Switch Converter (0 or 1 pcs) Ethernet communication board Wayne WM or Wayne WM or Wayne WM or Wayne WM or Wayne WM or W&M checksum 555F or 62D1 or 5A73 W&M checksum C10C Components included for electronic function, igem 2 CPU-board, 0, 1 (1 to 4 User) pc I/O-board 0, 1 pc Bootloader CPU board, 0 or 1 pc Dispenser App. SW CPU board, 0 or 1 pc Wayne WM or WM Wayne WU or WU Wayne WM or Wayne WM or WM or WU X W&M checksum 2294 F4AC or AC3E 6DE8 or F92E 4B0B W&M checksum 5A7A 43E3 or 784E BC7C or 59E8 4F87 Wayne WM The certificate, including appendices consists of 40 pages where this is page 15.

16 Control board, Additive injection, 0-1pc Wayne WM X Components included for electronic function, igem & igem 2 Isolated interface communication board, 0-1 pcs ATCL/RS422 communication board, 0-1 pcs IFSF/LON communication board, 0-1 pcs NPCL/SINP communication board, 0-1 pcs Wayne WM Wayne WM Wayne WM Wayne WM igem-isb board (pulse transmitter), Wayne WU or 1-3 pcs WU or WM TTL/CAN converter, 0-1 pc**** Software TTL/CAN converter, 0-1 pc**** Display board complete (volume, price & upd), 1-4 pcs) Display module TN neg (volume, price), 1-4 pcs Wayne WU W&M checksum 3FBD or 7E60 or 082A Wayne WU or WM or WM or WU or WM POLYTRONIX, PS-030ATL-02, REV.A (WM ) Display module TN neg (volume, price & upd), POLYTRONIX, 1-4 pcs PS-039ATL-02 (WM ), upd under or PS-044ATL-02 (WM ), upd right or PS-045ATL-02 (WM ), upd left or Display board (unit prices), 1-2 pcs Display module TN neg (unit price), 1-12 pcs Nozzle Switch Interface (0 or 1 pcs) Control Board igem printer (0, 1 or 2) igem Printer (0, 1 or 2) Board; Connector, Suction pump, IEC** Board; Connector, dispenser, IEC*** Board; Connector, without heating regulation and surge protection Power supply, 1 pc Heater including thermostat, 0-1 pc (mandatory for payment terminal) Wayne WU or WU or WM POLYTRONIX, PS-030ATL-02, (WM ) or POLYTRONIX, PS-031ATL-02, (WM ) or POLYTRONIX, PS-032ATL-02, (WM ) Wayne WU or WU X Innovision G (WR001816) Fujitsu FTP-629MCL374-R (WR001815) Wayne WU Wayne WU Wayne WXXXXXXX-000X Channel Well Technology, UAS150B, 150 W Max (WM ) Wayne WM (290 W) or equivalent approved by Wayne The certificate, including appendices consists of 40 pages where this is page 16.

17 Wayne ixpay TM secure payment platform (EC ) may be installed in the dispenser (see pictures 2 and 6), using the dispenser power supply. A display, Wayne ix TM Media platform, may be installed in the dispenser, at the same position as the payment terminal. * is replaced in dispenser variant ** is left out in dispenser variant *** is added in dispenser variant **** is added for ATC The certificate, including appendices consists of 40 pages where this is page 17.

18 1.4 Optional equipment and functions subject to MID requirements - ATC conversion device (Not for HVO) - Pre-set of volume or price***** - Volume totalizer - Blending (designation only e g 92, 95, 98 octane not 50/50, 70/30 etc) - Satellite (SAT and MASTER enable button in case of direct sales) - When using the measuring system to refill aircrafts or helicopters it is allowed to use a water elimination device according to OIML (E 2007) between meter and hose. For safety reasons it is required to drain the device on a regular base by opening the drain valve. This has to be done by a trained service technician on the measuring system under pressure with closed nozzle. This is to ensure that the hydraulic system is always filled with fuel. The drain valve has not to be sealed. - Additive injection function for injecting additive liquids to the fuel before the meter. A tank gauge meter is required in the storage tank for additive liquid to avoid injection of air into the fuel. See requirements for central pump function. ***** can be controlled through key pad on dispenser or by softkey on payment/media terminal 1.5 Technical documentation For market surveillance the construction and included components are described in 1.1, 1.2 and 1.3. The metrological software is identified by the checksum (W&M CRC value), which can be accessed according to Integrated equipment and functions not subject to MID Vapour recovery system with vapour pump, regulating proportional valves and an electronic board (for example Ivory power pump control WM066921) connected to the igem CPU board. The vapour flow is controlled by the electronic board or the igem CPU board. Optionally also a vapour recovery monitoring system consisting of a Vapour meter and belonging Intrinsic safe barrier may be used. Means for vapour recovery must not influence the accuracy of measurements such that the maximum permissible error is exceeded. For DEF, heating is installed to keep the liquid from freezing. As an option a pump circulates liquid downstream the meter between deliveries, through the coax hose to a container (max volume 2,55 litre in circulation system) to avoid freezing. 2. Technical data This chapter describes the fuel dispenser. For self-service devices see their certificate and their additional documentation such as documentation folders, see chapter Rated operating conditions Measurand Volume of liquid fuel expressed in litre. If ATC conversion device is included (not for DEF), the volume at base condition (15 C) is displayed. The calculations are based on OIML R63 (API/ASTM 54B) except The certificate, including appendices consists of 40 pages where this is page 18.

19 for petrol/ethanol mixtures where Verfahren 1 according to PTB dated April 11, 2011, is used. Measurement range Maximum flowrate (q max ) Minimum flowrate (q min ) Minimum measured quantity (mmq) Scale interval, volume display Maximum working pressure Minimum working pressure Liquid temperature range Type of liquids, volume sensor imeter, imeter2 and Xflo TM Viscosity range volume sensor imeter DM2-X UREA volume sensor LPG6000, GPL700 Volume sensor flow rate range, imeter Duplex (each meter) and Single imeter2 Duplex (each meter) and Single (Flow compensating Pules Transmitter) imeter2 Duplex (each meter) and Single (Not flow compensating Pules Transmitter) Xflo TM Duplex (each meter) and Single 4 to 70 l/min only for FAME/RME LPG6000 GPL to 200 l/min (DEF down to 10 l/min) 0,2 l/min 2,0 l or 5,0 l or 20 l (see specification of hoses and nozzles). As option, 5,0 l can be used on any configuration up to 5 l. For LPG and DEF, 5 l only. 0,01 l 0,3 MPa, 1,8 MPa only for LPG 0,12 MPa, not for LPG -30 C to +55 C, -25 C to +55 C only for FAME/RME -5 C to +35 C only for DEF -10 C to +50 C only for LPG (LPG6000) -5 to +35 only for LPG (GPL700) Petrol, kerosene, diesel, ethanol or FAME/RME/HVO 0,4-8,0 mpas DEF (Diesel Exhaust Fluid, e.g. AdBlue) LPG 0,2 to 70 l/min 4 to 70 l/min only for FAME/RME 2 to 40 l/min only for DEF 0,2 to 70 l/min 4 to 70 l/min only for FAME/RME 1,6 to 70 l/min 0,2 to 70 l/min only for Petrol 4 to 70 l/min only for FAME/RME 4 to 80 l/min 5 to 50 l/min only for LPG 10 to 50 l/min only for LPG Mixture conditions, two liquids 5% to 95% (designation only e g 92, 95, 98 octane not 50/50, 70/30 etc) The ratio between maximum and minimum flow rate should be at least 10 for single quality and 5 for blending quality, DEF and LPG. The certificate, including appendices consists of 40 pages where this is page 19.

20 Accuracy class 0,5 or 1,0 (LPG) Environments classes / influence quantities Mechanic: class M1 Electromagnetic: class E1 Ambient temperature limits: -40 C to +55 C (tested to +60 C) -25 C to +55 C for DEF and LPG +5 C to +55 C for igem printer Humidity: condensing Location: open 2.2 Other operating conditions Not applicable. 3. Interfaces and compatibility conditions Interface for vapour recovery systems. Communication between fuel dispenser and other parts of a measuring system (e g POS-systems) using one of the following non-reactive interfaces is evaluated and approved: SW protocol Hardware DART RS485 or RS422 (CPU board) LJCL RS422 (CPU board) Ferranti UKCL (CPU board) IFSF IFSF/LON communication board ATCL ATCL/RS422 communication board SINP NPCL/SINP communication board Most protocols do not include unit, for example 15 C. Instead this has to be handled during set up of the station controller and dispensers. It must be possible for the measuring system to 15 C on the ticket. Any other part of the measuring system (e g POS or OPT) may be connected to these interfaces without disturbing or influencing the metrological data of the dispenser. The applied protocol must be stated in both certificates. This does however not imply that the connected equipment fulfils the requirements of MID. When the dispenser is a part of a self-service arrangement as described in the beginning of chapter 1 the following requirements have to be fulfilled: The communication between the dispenser and the self-service device/devices has to be through one of the interfaces/protocols listed above. The interface/protocol used has to be approved/listed also in the certificate for the selfservice device/devices. The certificate, including appendices consists of 40 pages where this is page 20.

21 The connection has to be verified by the installer so the metrolgical data are presented in a way, whether it is an indicated, printed or memorised result, that meets the essential requirements of the MID The self-service arrangement is then a part of this certificate. 4. Requirements on production, putting into use and utilisation This chapter describes the fuel dispenser. For other parts of a self-service arrangements see first part of chapter Requirements on production No special requirements identified. 4.2 Requirements on putting into use Initial verification may be performed in the factory (module D or F) with a test liquid and conditions as approved for module D. This procedure is applicable for all intended liquids (petrol, kersosene, diesel ethanol fuel or FAME/RME), up to 4 mpas for Xflo TM and without viscosity limits for imeter & imeter2, i.e. no shift in the MPE is necessary. Follow installation instruction accompanying the equipment. LPG: Verify that an ongoing delivery stops automatically if the manual valve (if present) in the vapour return line in closed. If this is not the case, the valve has to be sealed in open position or labelled that it must be open. 4.3 Requirements for consistent utilisations No special requirements identified. 5. Control of the measuring tasks of the instrument in use This chapter describes the fuel dispenser. For other parts of a self-service arrangements see first part of chapter Documentation of the procedure No special requirements identified, standard procedure. For dispensers with ATC the volume at base condition is displayed in normal working mode. Alternative 1: When verifying the dispenser as a black box, the delivered volume measured in a volume standard V t ref is converted to volume at base condition V 15 using V 15 ref = V t ref x VCF where VCF, volume correction factor, is based on the quality and temperature t of the liquid. Alternative 2: When the display is showing ATC Revison and CRCs press the CRC button and the W&M-mode is active for 30 minutes (or until next push on the CRC-button) displaying V t, V 15, temperature t, product and density. A test well (inner diameter 4 mm) can be used for the reference temperature sensor. Nozzle out: Amount display Product and density for primary meter Volume display: Product and density for secondary meter UPD: Blank The certificate, including appendices consists of 40 pages where this is page 21.

22 In filling: Amount display Volume display: UPD: On nozzle return: Amount display Volume display: UPD: Uncompensated volume, V t Temperature for primary meter (momentary value) Temperature for secondary meter (momentary value) Volume at 15 C, V 15 altered with product and density for primary meter Uncompensated volume, V t altered with product and density for secondary meter Temperature t (mean value, volume weighted) LPG: A thermometer well is installed upstream the meter, to be used during verification. 5.2 Special equipment or software, if applicable No special requirements identified. 5.3 Identification Identification Hardware The construction and included components are described in 1.1, 1.2 and 1.3. Volume sensor(s), pulser(s), gas elimination device(s), board temperature module (ATC) and electronic calculator are identified in the data sheet accompanying the fuel dispenser Identification Software for igem The metrological software is identified by the checksum (W&M CRC value), which can be accessed by pressing the CRC button on the igem & igem 2 calculator CPU board. (Upon this also the program CRC values and software version number are indicated at the dispenser display.) P-AD67 555F Program CRC value (AD67) W & M CRC value (555F) SW version number (i. e ) CRC button and example of indication of software version on display For ATC this information is altered by Amount display Volume display: UPD: and Amount display Volume display: UPD: W&M CRC value on board temperature module Revision of board temperature module AtC W&M CRC value on TTL/CAN converter Revision of TTL/CAN converter Can The certificate, including appendices consists of 40 pages where this is page 22.

23 5.3.3 Identification Software for igem 2 The metrological software is identified by the checksum (W&M CRC value), which can be accessed by pressing the CRC button on the igem 2 calculator CPU board. The software versions and CRC values are shown in the following sequence: - CRC button placement - The first indicating on the sales volume display after the CRC button is pushed is the Firmeware version of the dispenser application. - After a few seconds the display will change and show the CRC for complete program both LR and non LR is included. - After an other few seconds the display will change again and the amount and volume display will show the W&M-CRC for the LR part of the code and the UPD will show LrCrC. It will looks like this: Example of W & M CRC - Then will the display change again and show the Bootloader Firmware version. - After that the Bootloader Firmware CRC. The UPD will show b CrC - When the display change again it will show the ATC information Amount display W&M CRC value on board temperature module Volume display: Revision of board temperature module UPD: AtC The certificate, including appendices consists of 40 pages where this is page 23.

24 5.4 Calibration-/adjustment procedure Dispensers with imeter & imeter2 volume sensors are calibrated/adjusted according to Wayne manual W (English version, other languages may be available). Dispensers with Xflo TM volume sensors are calibrated/adjusted according to Wayne manual WM (English version, other languages may be available). Dispensers with LPG6000 and GPL700 volume sensors are calibrated/adjusted according to Wayne manual WM (English version, other languages may be available). ATC is calibrated/adjusted according to Wayne manual WM (English version, other languages may be available, contact Wayne local technical support). 6. Security measures 6.1 Sealing Only the fuel dispenser is sealed, not Wayne ixpay TM secure payment platform, Wayne HeliX Pay Freestanding, Wayne Fusion forecourt system and Wayne Nucleus 9. For other self-service devices see their certificate and their additional documentation such as documentation folders, see chapter 1. The dispenser is sealed according to page 25 to 39. ATC: The board temperature module and temperature sensors are sealed according to pictures on page LPG: The volume sensor, pulser, differential valve, pressure calibration screw (if present) of the differential valve and manual valves in vapour return line are sealed (or labelled, see to 4.2) according to pictures on page Name plate (aluminium or vinyl sticker) is sealed to the frame with a small "vandal proof" label. - Electromechanical totalizer is sealed if used as a basis for legal transaction (page 38-39). The following components are not sealed, but protected/identified in the following way: - The pulsers are uniquely electronically identified by the calculator, including a presence check. NOTE: When using wire through screws etc. to make seals, ensure that the wire is as short and taut as possible. The closing stamp must be placed such as it is within reach for pressing with intended pliers, without dismantle surrounding components with the help of tools. The closing stamp can be of any suitable material. The certificate, including appendices consists of 40 pages where this is page 24.

25 Sealing of board temperature module Sealing of temperature sensors on imeter The certificate, including appendices consists of 40 pages where this is page 25.

26 Sealing of temperature sensors on Xflo TM Sealing of temperature sensors on imeter2 The certificate, including appendices consists of 40 pages where this is page 26.

27 Sealing of temperature sensors on LPG 6000 The certificate, including appendices consists of 40 pages where this is page 27.

28 Sealing of temperature sensors on GPL 700 The certificate, including appendices consists of 40 pages where this is page 28.

29 Sealing of hydraulic unit with imeter volume sensor The certificate, including appendices consists of 40 pages where this is page 29.

30 Sealing of hydraulic unit with Xflo TM volume sensor The certificate, including appendices consists of 40 pages where this is page 30.

31 Sealing of dispenser variant (central pump) with imeter volume sensor The certificate, including appendices consists of 40 pages where this is page 31.

32 Sealing of dispenser variant (central pump) with Xflo TM volume sensor The certificate, including appendices consists of 40 pages where this is page 32.

33 Sealing of dispenser with imeter2 volume sensor The certificate, including appendices consists of 40 pages where this is page 33.

34 Sealing of LPG 6000 volume sensor The certificate, including appendices consists of 40 pages where this is page 34.

35 Sealing of LPG 6000 volume sensor when manuallay calibrated The certificate, including appendices consists of 40 pages where this is page 35.

36 The certificate, including appendices consists of 40 pages where this is page 36.

37 Sealing of GPL 700 Volume sensor The certificate, including appendices consists of 40 pages where this is page 37.

38 Example of sealing of igem with electromechanical totalizer (if used as a basis for legal transaction) for Helix see detail B and C. For sealing of the program load PRG LOAD switch for Helix see detail A. Example of sealing of igem 2 electronic module with electromagnetic totalizers (if used as a basis for legal transaction). Even though no electromagnetic totalizer is connected the sealing have to include the CPU-module and the sealing screw in detail 1 The certificate, including appendices consists of 40 pages where this is page 38.

39 Example of sealing of igem 2 Generation 2 electronic module with electromagnetic totalizers (if used as a basis for legal transaction). Even though no electromagnetic totalizer is connected the sealing have to include the CPU-module and the sealing screw in detail A & B 6.2 Data logger A data storage device (included in Wayne Fusion forecourt system, Nucleus 9, for other self-service devices see their certificate and their additional documentation such as documentation folders. is only mandatory, when the measuring system includes attended post-payment including sale stacking or unattended delayed-payment. The certificate, including appendices consists of 40 pages where this is page 39.

40 7. Labelling and inscriptions This chapter describes the fuel dispenser, for other self-service devices see their certificate and their additional documentation such as documentation folders, see chapter Information to be borne by and to accompany the instrument The name plate mounted on the instrument shall contain the following information: - the name or trademark of the manufacturer - the serial number and year of manufacture - the designation or type name (according to Product names and designation, page 3-4) - the nature of the liquid to be measured and viscosity class (not for LPG and DEF) - the EC-type examination certificate number, 0402-MID , where only is mandatory - the accuracy class - the ambient temperature range - the temperature range of the dispensed liquid - minimum measured quantity - max. flow rate Qmax - min. flow rate Qmin - max. pressure Pmax - mechanical class - electromagnetic class Volume sensor(s), pulser(s), board temperature module, gas elimination device(s) and electronic calculator are identified on the data sheet. This data sheet does not have to be sealed. 7.2 Conformity marking in accordance to MID article 17 The instrument shall be marked in accordance to MID article 17 which e.g. describes the CE-marking together with M, year of marking and the notified body number. 7.3 Further inscriptions, if necessary Minimum measured quantity shall be inscribed on the indicator face. If ATC is 15 C shall be marked adjacent to the volume display. Display for ATC 15 C The certificate, including appendices consists of 40 pages where this is page 40.

EU-type examination Certificate

EU-type examination Certificate 0402-MID-107026 Wayne Helix Fuel dispenser TM and self-service devices Issued to Wayne Fueling Systems Sweden AB, P O Box 50559, SE-202 15 Malmö, Sweden. In respect of (type of instrument) A family of

More information

EU-type examination Certificate

EU-type examination Certificate 0402-MID-107026 Wayne Helix Fuel dispenser TM and self-service devices Issued to Wayne Fueling Systems Sweden AB, P O Box 50559, SE-202 15 Malmö, Sweden. In respect of (type of instrument) A family of

More information

EC type Examination Certificate

EC type Examination Certificate EC type Examination Certificate 0402-MID-107021 Wayne Global Star, Global Century and self-service devices Issued to Wayne Fueling Systems Sweden AB, P O Box 50559, SE-202 15 Malmö, Sweden In respect of

More information

EU-TYPE EXAMINATION CERTIFICATE

EU-TYPE EXAMINATION CERTIFICATE Wayne Global Star, Global Century and self-service devices Issued to: Wayne Fueling Systems Sweden AB, P O Box 50559, SE-202 15 Malmö, Sweden In respect of (type of instrument) A family of fuel dispensers,

More information

Parts Certificate Certificate for a part of a measuring system for LOTW

Parts Certificate Certificate for a part of a measuring system for LOTW No. 107030 Wayne ixpay TX secure payment platform, a payment terminal (OPT) for cards Issued to Wayne Fueling Systems Sweden AB Hanögatan 10, SE-211 24 Malmö, Sweden In respect of (part of instrument)

More information

Evaluation Certificate

Evaluation Certificate SC0414-14 Certificate for a part of a measuring system for LOTW Forecourt controller, FuelNet Manager Issued to CODAB AB Höjdrodergatan 24, SE-212 39 Malmö, Sweden In respect of (part of instrument) Forecourt

More information

Evaluation Certificate

Evaluation Certificate Payment terminal (OPT) for cards and bank notes, Wayne ixpay TM secure payment platform Issued to Wayne Fueling Systems Sweden AB P O Box 50559, SE-20215 Malmö, Sweden In respect of (part of instrument)

More information

EC type Examination Certificate

EC type Examination Certificate EC type Examination Certificate 0402-MID-51 65 02 Issued to Structab AB, Slottsmöllan 14B, 302 31 HALMSTAD, Sweden In respect of (type of instrument) Taximeter MegTax 350 and MegTax 310 In accordance with

More information

Evaluation Certificate Certificate for a part of a measuring system for LOTW

Evaluation Certificate Certificate for a part of a measuring system for LOTW No. SC311-12 Outdoor payment terminal for cards and banknotes, PaySys Issued to NPS A/S (Nordic Petrol Systems) Landbrugsvej 6, DK-5260 Odense S, Denmark In respect of (part of instrument) Outdoor payment

More information

Parts Certificate. Outdoor Payment Terminal KT-OPT - including KT-Retail and KT-Account SC

Parts Certificate. Outdoor Payment Terminal KT-OPT - including KT-Retail and KT-Account SC SC0099-18 Outdoor Payment Terminal KT-OPT - including KT-Retail and KT-Account Issued to Knowtronic ApS Stationsvej 83, DK-4684 HOLMEGARD, Denmark In respect of (part of instrument) OPT Outdoor Payment

More information

WELMEC European cooperation in legal metrology

WELMEC European cooperation in legal metrology WELMEC 10.6 Issue 1 WELMEC European cooperation in legal metrology Guide for Sealing of Fuel Dispensers (Measuring Systems for Liquids other than Water) May 2008 1 WELMEC European cooperation in legal

More information

EC type-examination certificate UK/0126/0072 Revision 2

EC type-examination certificate UK/0126/0072 Revision 2 UK/0126/0072 MI-005 EC type-examination certificate UK/0126/0072 Revision 2 issued by: The National Measurement Office Notified Body Number 0126 In accordance with the requirements of the Measuring Instruments

More information

ULTRASONIC FLOW SENSOR QALCOSONIC FLOW 2

ULTRASONIC FLOW SENSOR QALCOSONIC FLOW 2 AB AXIS INDUSTRIES ULTRASONIC FLOW SENSOR QALCOSONIC FLOW 2 TECHNICAL DESCRIPTION, INSTALLATION AND USER INSTRUCTIONS PESF2V01 KAUNAS Contents Page SAFETY INFORMATION... 1. APPLICATION FIELD... 2. TECHNICAL

More information

Parts Certificate Certificate for a part of a measuring system for LOTW No. SC

Parts Certificate Certificate for a part of a measuring system for LOTW No. SC No. SC0257-15 Forecourt controller, PSS 5000 Issued to Doms ApS, Formervangen 28, DK-2800 Glostrup, Denmark. In respect of (part of instrument) Forecourt controller and memory device, a purely digital

More information

Model description & Accessories

Model description & Accessories FUEL DISPENSERS SERIES OCEAN BMP4000.O - EURO Model description & Accessories Document: Fuel Dispensers Series OCEAN BMP4000.O - EURO, Model description & Accessories File: TB036-EN OCEAN4000O_EURO_ModelDescription,

More information

Committee Chair, National Type Evaluation Program Committee Issued: December 27, M Street, Suite 110 / Lincoln, Nebraska 68508

Committee Chair, National Type Evaluation Program Committee Issued: December 27, M Street, Suite 110 / Lincoln, Nebraska 68508 Page 1 of 6 For: Retail Motor Fuel Dispenser Digital Electronic Computing Model: A(BC/DE)FG-HJK Generic Name: Helix Max. Capacity: $9999.00 Total Sale 999.000 Total Volume $9.999 Total Unit Price Submitted

More information

Gilbarco. Pumps & Dispensers Series SK700-2 with LPG. Spare Parts List. Document not subject to updating service

Gilbarco. Pumps & Dispensers Series SK700-2 with LPG. Spare Parts List. Document not subject to updating service Gilbarco Pumps & Dispensers Series SK700- with LPG Spare Parts List Document not subject to updating service Part No. 0 9 Issue, August 0 Contents Contents A - Hydraulics B Display housing C - Hose column

More information

EC Type-Approval Certificate UK2853 Revision 4

EC Type-Approval Certificate UK2853 Revision 4 UK 2853 V(0)a EC Type-Approval Certificate UK2853 Revision 4 issued by: The National Measurement Office Notified Body Number 0126 In accordance with the requirements of the Non-automatic Weighing Instruments

More information

CERTIFICATE OF APPROVAL

CERTIFICATE OF APPROVAL Certificate 1584 Overseas Certificate No: 5/6A/91A Wellington, New Zealand CERTIFICATE OF APPROVAL Weights and Measures Regulations 1999 Part 1 Regulations 5 and 6 This certifies that the Compac MR40P,

More information

WELMEC External Auxiliary Power Supply of Electrical Energy Meters

WELMEC External Auxiliary Power Supply of Electrical Energy Meters WELMEC 11.8 2018 External Auxiliary of Electrical Energy Meters WELMEC is a cooperation between the legal metrology authorities of the Member States of the European Union and EFTA. This document is one

More information

EC Type-Approval Certificate UK 2655 Revision 2

EC Type-Approval Certificate UK 2655 Revision 2 UK 2655 V(0)a EC Type-Approval Certificate UK 2655 Revision 2 Issued by: National Measurement Office Notified Body Number 0126 In accordance with the requirements of the Non-automatic Weighing Instruments

More information

Centurytm Series Fuel Dispenser

Centurytm Series Fuel Dispenser Centurytm Series Fuel Dispenser Dresser Wayne Century Series Fuel Dispenser The Dresser Wayne Century Series fuel dispenser combines the benefits of fast fueling with the value of a compact design. It

More information

Certificate of EC type-approval of a measuring instrument Number: UK 2489 Revision 4

Certificate of EC type-approval of a measuring instrument Number: UK 2489 Revision 4 (UK 2489) V(0)a United Kingdom of Great Britain and Northern Ireland Certificate of EC type-approval of a measuring instrument Number: UK 2489 Revision 4 issued by the Secretary of State for Business,

More information

SK700-II ADBLUE ADBLUE DISPENSERS ADAPTED TO FIT YOUR NEEDS

SK700-II ADBLUE ADBLUE DISPENSERS ADAPTED TO FIT YOUR NEEDS SK700-II ADBLUE ADBLUE DISPENSERS ADAPTED TO FIT YOUR NEEDS > Standalone, Combi or Integrated > Ensures maximum uptime and damage free filling > A reliable solution to meet any customer needs > Also available

More information

Thermocouple with spring-loaded tip Model TC55

Thermocouple with spring-loaded tip Model TC55 Electrical temperature measurement Thermocouple with spring-loaded tip Model TC55 WIKA data sheet TE 65.55 for further approvals see page 5 Applications Bearing temperature measurement on: Pumps Gears

More information

Fusion4 MicroBlender (ATEX/IECEx) The intelligent blend controller for all single stream blending applications.

Fusion4 MicroBlender (ATEX/IECEx) The intelligent blend controller for all single stream blending applications. Fusion4 MicroBlender (ATEX/IECEx) The intelligent blend controller for all single stream blending applications. The Fusion4 MicroBlender delivers a complete solution for those requiring secure, precision

More information

The Council Directive 2009/23/EC on non-automatic weighing instruments.

The Council Directive 2009/23/EC on non-automatic weighing instruments. EC type-approval certificate Page 1 of 5 Issued by In accordance with Manufacturer In respect of Characteristics NMi Certin B.V. Hugo de Grootplein 1 3314 EG Dordrecht The Netherlands The Council Directive

More information

SK700-II THE COMPLETE DISPENSING SOLUTION. Building Better Business

SK700-II THE COMPLETE DISPENSING SOLUTION. Building Better Business SK700-II THE COMPLETE DISPENSING SOLUTION Building Better Business Why Gilbarco Veeder-Root? Our experience and expertise in the fuelling industry means we understand a forecourt s business and consumer

More information

6" Steel Model G6. Smith Meter Rotary Vane PD Meters. Features. Operating Specifications Maximum Flow Rate. Options

6 Steel Model G6. Smith Meter Rotary Vane PD Meters. Features. Operating Specifications Maximum Flow Rate. Options SPECIFICATIONS 6" Steel Model G6 Bulletin SS01014 Issue/Rev. 1.0 (4/18) Smith Meter Rotary Vane PD Meters The Smith Meter Model G6 Meter is a 6", double-case, straight-through rotary vane type positive

More information

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control. Benefits.

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control. Benefits. GE Measurement & Control Sentinel LCT Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement Benefits Extremely reliable and highly accurate flowmeter, designed specifically for custody

More information

Nozzles Lane-oriented and High-hose Attachment Downloadable Software. Endress & Hauser LPG Mass DN15 Diesel Exhaust Fluid (DEF)

Nozzles Lane-oriented and High-hose Attachment Downloadable Software. Endress & Hauser LPG Mass DN15 Diesel Exhaust Fluid (DEF) Page 1 of 11 For: Retail Motor Fuel Dispenser (RMFD) Dispenser, Electronic Computing Models: NA, NPA, NPB, NPC and Field Upgrade Modules Gilbarco Part Number ENC-DEF-RF Generic Names: Encore 500, Encore

More information

National comparison on verification of fuel dispensers

National comparison on verification of fuel dispensers 16 th International Congress of Metrology, 06011 (2013) DOI: 10.1051/ metrology/201306011 C Owned by the authors, published by EDP Sciences, 2013 National comparison on verification of fuel dispensers

More information

The Global Star Fuel Dispenser: Style meets substance.

The Global Star Fuel Dispenser: Style meets substance. The Global Star Fuel Dispenser: Style meets substance. Style meets substance A fuel dispenser is more than just a petrol pump. It s an investment, a revenue source, even a marketing tool. The dispenser

More information

Tubeskin thermocouple assembly Model TC59-V

Tubeskin thermocouple assembly Model TC59-V Electrical temperature measurement Tubeskin thermocouple assembly Model TC59-V WIKA data sheet TE 65.59 further approvals see page 7 V-PAD Applications Chemical industry Superheated steam applications

More information

Process resistance thermometer Model TR12-B, for additional thermowell Model TR12-M, basis module

Process resistance thermometer Model TR12-B, for additional thermowell Model TR12-M, basis module Electrical temperature measurement Process resistance thermometer Model TR12-B, for additional thermowell Model TR12-M, basis module WIKA data sheet TE 60.17 for further approvals see page 6 Applications

More information

WELMEC. European Cooperation in Legal Metrology

WELMEC. European Cooperation in Legal Metrology WELMEC 8.16-1 Issue 3 May 2013 WELMEC European Cooperation in Legal Metrology Measuring Instruments Automatic Catchweighers Corresponding Tables MID-006 II WELMEC European Cooperation in Legal Metrology

More information

WAYNE HELIX TM FUEL DISPENSER ALTERNATIVE ENERGY SOLUTIONS. Designed for you. world

WAYNE HELIX TM FUEL DISPENSER ALTERNATIVE ENERGY SOLUTIONS. Designed for you. world WAYNE HELIX TM FUEL DISPENSER ALTERNATIVE ENERGY SOLUTIONS Designed for you. Engineered world for the Prepare your forecourt for the eco invasion Hybrid vehicles using LPG (Liquefied Petroleum Gas), ethanol,

More information

IFX-M4-03 IFX-M4-03_D_E_2017_05_REV.0

IFX-M4-03 IFX-M4-03_D_E_2017_05_REV.0 IFX-M4-03 IFX-M4-03_D_E_2017_05_REV.0 Table of contents PRINCIPLE... 4 HOW TO ORDER... 4 TECHNICAL DATA... 5 Table 1.1... 6 Table 1.2... 7 Table 1.3... 7 Straight pipelines lengths... 7 Conveying liquid...

More information

CONTOIL VZFA/VZOA , versions for higher requirements / applications

CONTOIL VZFA/VZOA , versions for higher requirements / applications CONTOIL VZF/VZO 4...50, versions for higher requirements / applications For applications requiring an increased accuracy of ±0.5 % or better, such as: Measurement of L heating fuel or diesel in testing

More information

English version of. Executive Order on vehicles' technical compatibility with the rail network (Bekendtgørelse nr af 30. november 2012) Preface

English version of. Executive Order on vehicles' technical compatibility with the rail network (Bekendtgørelse nr af 30. november 2012) Preface English version of Executive Order on vehicles' technical compatibility with the rail network (Bekendtgørelse nr. 1127 af 30. november 2012) Preface Please note that the English version is for informational

More information

Designed for you. Engineered for the world.

Designed for you. Engineered for the world. WAYNE HELIX ALTERNATIVE ENERGY SOLUTIONS Designed for you. Engineered for the world. Wayne.com Prepare your forecourt for the eco invasion Hybrid vehicles using LPG (Liquefied Petroleum Gas), ethanol,

More information

Thermocouple Model TC10-H without thermowell

Thermocouple Model TC10-H without thermowell Electrical temperature measurement Thermocouple Model TC10-H without thermowell WIKA data sheet TE 65.08 for further approvals see page 7 Applications For direct installation in the process Machine building

More information

Horizon. Dependable. Protecting. dispensing. your investment. Behind Every Successful Forecourt

Horizon. Dependable. Protecting. dispensing. your investment. Behind Every Successful Forecourt Horizon Dependable dispensing Protecting your investment Key Features Timeless and reliable, the Horizon is a flexible solution for your forecourt needs, maximising uptime and built to last in the most

More information

Standards Are Fit For Use Standard must be free of leaks, dents and seals must be intact

Standards Are Fit For Use Standard must be free of leaks, dents and seals must be intact Test Procedures for Inspecting Fuel Dispensers (90 liters/min or less) 1. Standards 2. Device Use 3. Visual Exam 4. Performance 5. Sealing Physical Standards Physical Standards Certified Within Prescribed

More information

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Sensing & Inspection Technologies. Benefits.

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Sensing & Inspection Technologies. Benefits. GE Sensing & Inspection Technologies Sentinel LCT Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement Benefits Extremely reliable and highly accurate flowmeter, designed specifically

More information

Insertion magnetic inductive flowmeter

Insertion magnetic inductive flowmeter Insertion magnetic inductive flowmeter Sensor without moving parts Flowmeter with On/Off control Application related calibration by Teach-In function Clean in place (CIP) FDA-compliant materials Type 8041

More information

Legal Metrology Control of a Liquefied Petroleum Gas Transfer Standard and Field Practice

Legal Metrology Control of a Liquefied Petroleum Gas Transfer Standard and Field Practice Legal Metrology Control of a Liquefied Petroleum Gas Transfer Standard and Field Practice Kun-Chih Tsai, Win-Ti Lin, Jiunn-Haur Shaw, Cheng-Tsair Yang, Chun-Min Su Center for Measurement Standards, CMS/ITRI

More information

CM3-E Operation Manual DOK-347E / Rev.:1.01 KH / October 1999 Portable 3 turbine check meter

CM3-E Operation Manual DOK-347E / Rev.:1.01 KH / October 1999 Portable 3 turbine check meter -E DOK-347E / Rev.:1.01 KH / October 1999 Portable 3 turbine check meter Contents 1 General Remarks... 1-1 1.1 About This Manual... 1-1 1.2 How to Use This Manual... 1-1 2 Approval... 2-1 2.1 Explosion

More information

Title: Terms and Conditions for the Approval of Coriolis Liquid Meters. Effective Date: Page: 1 of 9 Revision: 1

Title: Terms and Conditions for the Approval of Coriolis Liquid Meters. Effective Date: Page: 1 of 9 Revision: 1 Effective Date: 2012-12-01 Page: 1 of 9 Revision: 1 1.0 Application These terms and conditions apply to Coriolis metering assemblies and to metering installations used in trade 1. 2.0 Definitions In this

More information

TYPE-CERTIFICATE DATA SHEET

TYPE-CERTIFICATE DATA SHEET TYPE-CERTIFICATE DATA SHEET No. E.073 for Arriel 1 series engines Type Certificate Holder 64510 Bordes France For Models: Arriel 1A Arriel 1A1 Arriel 1A2 Arriel 1B Arriel 1C Arriel 1C1 Arriel 1C2 Arriel

More information

Designed for you- Engineered for the. World. Wayne Helix Fuel Dispensers

Designed for you- Engineered for the. World. Wayne Helix Fuel Dispensers Designed for you- Engineered for the World Wayne Helix s Designed for you. The Wayne Helix fuel dispenser line was designed for you. With user feedback from across the globe influencing the design, these

More information

Diploma in Consumer Affairs and Trading Standards LEGAL METROLOGY LAW NOVEMBER 2014

Diploma in Consumer Affairs and Trading Standards LEGAL METROLOGY LAW NOVEMBER 2014 Diploma in Consumer Affairs and Trading Standards LEGAL METROLOGY LAW NOVEMBER 2014 Candidates answering the questions from the Scottish or Welsh law viewpoint: Please ensure you write Scottish or Welsh

More information

ULTRASONIC FLOW SENSOR IFX-M4-01

ULTRASONIC FLOW SENSOR IFX-M4-01 ULTRASONIC FLOW SENSOR IFX-M4-01 TECHNICAL DESCRIPTION, OPERATING INSTRUCTION IFX-M4-01 2012-09-10 TABLE OF CONTENTS 1. APPLICATION... 3 2. TECHNICAL DATA... 4 3. PACKAGE CONTENT... 6 4. OPERATING PRINCIPLE...

More information

TECHNICAL CERTIFICATE

TECHNICAL CERTIFICATE MOTOR VEHICLE RESEARCH INSTITUTE Ltd. UNECE Homologation Laboratory E8/C 12 Lihovarská, Praha 9, CZ 180 68 Fax: +420 284 811 038 E-mail: uvmv@uvmv.cz Telephone: +420 284 814 050 Certificate: 20429-01 Regulation:

More information

SELECT TM SERIES ELECTRONIC FLEET FUEL DISPENSERS

SELECT TM SERIES ELECTRONIC FLEET FUEL DISPENSERS SELECT TM SERIES ELECTRONIC FLEET FUEL DISPENSERS WFS140022-B_select_series_8pg_newdesign_07212014.indd 1 5/21/16 6:09 PM Wayne Select Series Electronic Fleet Fuel Dispensers Advanced technology delivers

More information

PETROL. Double Case PD Flowmeters. Trust in us Our Quality Counts. Technical Bulletin. PETROL Instruments S.r.l.

PETROL. Double Case PD Flowmeters. Trust in us Our Quality Counts. Technical Bulletin. PETROL Instruments S.r.l. Double Case PD Flowmeters Technical Bulletin The trusted specialist manufacturer of high precision instruments that relies upon the accurate measurement of fluid volumes Trust in us Our Quality Counts

More information

UK Weighing Federation Technical Articles

UK Weighing Federation Technical Articles GLOSSARY The source of each definition is identified by the superscript number and listed out in full at the end of this glossary. Accuracy classification (1) classification as a Class I, Class II, Class

More information

SIRIUS 3RU2 Thermal Overload Relays

SIRIUS 3RU2 Thermal Overload Relays Overview 1 2 3 4 6 1 2 NSB0_0207a Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors. The overload relay can be connected directly to

More information

HYDRONIC LIFT SOLUTION FOR A3 AMENDMENT

HYDRONIC LIFT SOLUTION FOR A3 AMENDMENT Page 1/38 Safety Valve HSV Installation, maintenance and startup guide HYDRONIC LIFT SOLUTION FOR A3 AMENDMENT Page 2/38 2011 by Hydronic Lift Spa All right reserved. This documentation, in whole and/or

More information

GREASE CONTROL GUNS GREASE CONTROL GUNS Grease control gun Grease control gun with rigid stem and 3 jaw connector ( ).

GREASE CONTROL GUNS GREASE CONTROL GUNS Grease control gun Grease control gun with rigid stem and 3 jaw connector ( ). MEASURE AND CONTROL GREASE CONTROL GUNS AND ACCESSORIES GREASE METERS OIL CONTROL GUNS AND ACCESSORIES OIL METERS OIL METER ACCESSORIES FLUID CONTROL GUNS FLUID METERS HIGH FLOW IN LINE METERS ADVANCED

More information

DISPENSING SYSTEMS

DISPENSING SYSTEMS DISPENSING SYSTEMS 800-621-4137 www.whyips.com Retail Dispensers Encore 700S Dispensers Dispenser Features: Secure your competitive advantage and increase profits with Gilbarco Veeder Root s Encore 700S

More information

PHOENIX CONTACT

PHOENIX CONTACT Current transformers INTERFACE Data sheet 03359_en_03 PHOENIX CONTACT 20-04-04 Description The PACT Analog current transformers form a complete range of bus-bar, plug-in and winding current transformers

More information

DC Energy Measurement for EV Charging Stations

DC Energy Measurement for EV Charging Stations DC Energy Measurement for EV Charging Stations Existing application: railway on-board energy meter Energy Measurement Function (EMF) Voltage measurement (DV) Current measurement (ITC) Application requirements

More information

GASBOY FLEET & COMMERCIAL

GASBOY FLEET & COMMERCIAL GASBOY FLEET & COMMERCIAL F U E L I N G ATLAS SERIES FUELING EQUIPMENT CONTENTS Gasboy Overview 1 9853 Electronic High Flow 2 9850 Electronic Ultra-Hi 4 9216 Satellite 6 9862 Electronic DEF 8 9872 Electronic

More information

VAPORIX-PCM. Technical Documentation. Corrective control module for connection to VAPORIX-Control. Version: 3 Edition: Art.

VAPORIX-PCM. Technical Documentation. Corrective control module for connection to VAPORIX-Control. Version: 3 Edition: Art. Technical Documentation VAPORIX-PCM Corrective control module for connection to VAPORIX-Control Version: 3 Edition: 2016-08 Art. No: 350102 FAFNIR GmbH Schnackenburgallee 149 c 22525 Hamburg, Germany Tel.:

More information

Certificate of Approval NMI 12/1/8

Certificate of Approval NMI 12/1/8 Bradfield Road, West Lindfield NSW 2070 Certificate of Approval Issued by the Chief Metrologist under Regulation 60 of the National Measurement Regulations 1999 This is to certify that an approval for

More information

VZFA/VZOA MISURATORI DI PORTATA FUEL OIL METERS. CONTOIL VZFA/VZOA , versions for special requirements / applications

VZFA/VZOA MISURATORI DI PORTATA FUEL OIL METERS. CONTOIL VZFA/VZOA , versions for special requirements / applications VZFA/VZOA FUEL OIL METERS MISURATORI DI PORTATA CONTOIL VZFA/VZOA 5...50, versions for special requirements / applications For applications requiring an increased accuracy of ± % or better, such as: Versions

More information

Tubeskin thermocouple assembly Model TC59-V

Tubeskin thermocouple assembly Model TC59-V Electrical temperature measurement Tubeskin thermocouple assembly Model TC59-V WIKA data sheet TE 65.59 further approvals see page 7 V-PAD Applications Chemical industry Superheated steam applications

More information

SK700-II LPG. Easy LPG solutions adapted to fit your needs

SK700-II LPG. Easy LPG solutions adapted to fit your needs SK700-II LPG Easy LPG solutions adapted to fit your needs > Seamless LPG integrations with SK700-II > Standalone and combi versions available > ATEX and MID approved > Field proven LPG hydraulics design

More information

US-S/FFL. Ultrasonic energy meters. Function. Flexible design. Connection. Mounting. High reliability

US-S/FFL. Ultrasonic energy meters. Function. Flexible design. Connection. Mounting. High reliability Revision 2017-08-15 Ultrasonic energy meters Flanged ultrasonic energy meters, intended for heating or cooling. Size DN25 DN100 Nominal flow 3.5 60 m³/h For horizontal or vertical mounting No data loss

More information

Tubeskin thermocouple assembly Model TC59-W

Tubeskin thermocouple assembly Model TC59-W Electrical temperature measurement Tubeskin thermocouple assembly Model TC59-W WIKA data sheet TE 65.58 further approvals see page 7 WELD-PAD Applications Chemical industry Power generation Refineries

More information

Tillers Motor hoes (combustion engine powered)

Tillers Motor hoes (combustion engine powered) Compliance Guide Rev.2.1, Edition 04/2018 This guide is intended to help market surveillance authorities with the checking of conformity of combustion engine powered brush-cutters and grass trimmers in

More information

AVL PLU 131U FLOW METER

AVL PLU 131U FLOW METER CONSUMPTION MEASUREMENT TECHNOLOGIES AVL PLU 131U FLOW METER AVL PLU131 UREA FLOW MEASUREMENT SENSORS Function Summary The AVL PLU 131U-020 Flow Sensor has been designed for transient flow rate measurement

More information

Screw-type and measuring capsule heat meter with IrDA interface and an interface for retrofitting external modules or with integrated communication.

Screw-type and measuring capsule heat meter with IrDA interface and an interface for retrofitting external modules or with integrated communication. Data sheet DST2-QHEA-GB0 HMx / 11.05.2016 - V 1.0 Heat meter Q heat 5 Screw-type and measuring capsule heat meter with IrDA interface and an interface for retrofitting external modules or with integrated

More information

Threaded resistance thermometer Model TR10-C, with fabricated thermowell model TW35

Threaded resistance thermometer Model TR10-C, with fabricated thermowell model TW35 Electrical temperature measurement Threaded resistance thermometer Model TR10-C, with fabricated thermowell model TW35 WIKA data sheet TE 60.03 for further approvals see page 7 Applications Machinery,

More information

Resistance thermometer For sanitary applications Model TR22-B, for orbital welding

Resistance thermometer For sanitary applications Model TR22-B, for orbital welding Electrical temperature measurement Resistance thermometer For sanitary applications Model TR22-B, for orbital welding WIKA data sheet TE 60.23 for further approvals see page 11 Applications Sanitary applications

More information

Chain-saws (combustion engine powered)

Chain-saws (combustion engine powered) Compliance Guide Rev.4.2, Edition 04/2018 Chain-saws (combustion engine powered) European Garden Machinery Federation EGMF Bd Reyers 80, 1030 Brussels, Belgium secretariat@egmf.org +32 2 206 68 66 This

More information

Technical Information Liquiline System CAT810

Technical Information Liquiline System CAT810 TI01138C/07/EN/02.16 71341422 Products Solutions Services Technical Information Control of sample preparation by the Liquiline System CA80 or a time control system Automatic sample preparation system for

More information

Certificate: _01 / 29 April 2014

Certificate: _01 / 29 April 2014 Test report: 936/21219344/B of 01 October 2013 Initial certification: 05 March 2013 Expiry date: 04 March 2018 Publication: BAnz AT 01 April 2014 B12, chapter II, No. 2.1 Approved application The tested

More information

SonoMeter 30 Energy Meters

SonoMeter 30 Energy Meters SonoMeter 30 Energy Meters Description MID examination certificate no.: LT-1621-MI004-020 The Danfoss SonoMeter 30 is a range of ultrasonic, compact energy meters intended for measuring energy consumption

More information

Integrated temperature test and calibration bench Model CBS-SC4000

Integrated temperature test and calibration bench Model CBS-SC4000 Calibration technology Integrated temperature test and calibration bench Model CBS-SC4000 WIKA data sheet CT 92.33 Applications Testing and calibration of temperature measuring instruments such as: - Mercury

More information

f-pod Intelligent Fuel Bowser

f-pod Intelligent Fuel Bowser f-pod Intelligent Fuel Bowser The f-pod is a new generation of race fuel bowser which raises the bar in technology, safety, accuracy and ease of use. The f-pod has been developed with input of leading

More information

AVL SHOT TO SHOT PLU 131 UREA FLOW MEASURING SYSTEM

AVL SHOT TO SHOT PLU 131 UREA FLOW MEASURING SYSTEM UREA INJECTION TESTING AVL SHOT TO SHOT PLU 131 UREA FLOW MEASURING SYSTEM Function Summary The AVL Shot To Shot (STS) PLU 131 UREA flow measuring system is based on the well-proven PLU 131 flow metering

More information

TATSUNO-BENČ EUROPE A.S.

TATSUNO-BENČ EUROPE A.S. TATSUNO-BENČ EUROPE A.S. SHARK BMP500.S - JUNIOR Description Models & Options Document: SHARK BMP500.S - JUNIOR - Description Models & Options Reference: TB030-EN SHARK500S_JUNIOR_Description.doc Revision

More information

Heat Meter Integrator

Heat Meter Integrator Heat Meter Integrator Features Simply operation Integral wall and DIN-rail mounting bracket Pulsed or M-Bus output options Measures heating or cooling and heat/cooling Specification Product Codes Temperature

More information

LK Manifold Shunt VS2

LK Manifold Shunt VS2 LK Manifold Shunt VS2 Design LK Manifold Shunt VS2 is a shunt unit with a two way control valve used in systems with a primary pump. The shunt unit is mountable from both the left and right of LK Manifolds.

More information

VAPORIX The Automatic Monitoring System for Active Vapour Recovery

VAPORIX The Automatic Monitoring System for Active Vapour Recovery VAPORIX The Automatic Monitoring System for Active Vapour Recovery SECON VAPORIX-Control VAPORIX-Flow Sensors & Systems Worldwide: FAFNIR GmbH: Innovation with Tradition. Quality and Satisfaction made

More information

OIML CERTIFICATE OF CONFORMITY

OIML CERTIFICATE OF CONFORMITY Member State of OIML United Kingdom of Great Britain and Northern Ireland OIML CERTIFICATE OF CONFORMITY Issuing authority: Person responsible: Applicant: Manufacturer: Identification of the certified

More information

Ride-on lawnmowers (combustion engine powered)

Ride-on lawnmowers (combustion engine powered) Compliance Guide Rev.2.3 Edition 04/2018 Ride-on lawnmowers (combustion engine powered) This guide is intended to help market surveillance authorities with the checking of conformity of combustion engine

More information

Type Operating Instructions. Bedienungsanleitung Manuel utilisateur

Type Operating Instructions. Bedienungsanleitung Manuel utilisateur Water flow rate transmitter Wasser-Durchfluss-Transmitter Transmetteur de débit d eau Operating Instructions Bedienungsanleitung Manuel utilisateur We reserve the right to make technical changes without

More information

EQUALIS S. Flow computer for depots. Metering Solutions Metering Solutions. Very open communication skills. Field of application.

EQUALIS S. Flow computer for depots. Metering Solutions Metering Solutions. Very open communication skills. Field of application. Countum Group Countum Group computer for depots EQUALIS S Equalis S is a field batch controller designed for oil depots and terminals. It meets all the requirements for tanker trucks, railcar and ships

More information

Certificate of constancy of performance

Certificate of constancy of performance 0402-CPR-SC0221-16 In compliance with Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 (the Construction s Regulation or CPR), this certificate applies to the construction

More information

Pressure balance Differential pressure version Model CPB5600DP

Pressure balance Differential pressure version Model CPB5600DP Calibration technology Pressure balance Differential version Model CPB5600DP WIKA data sheet CT 31.56 for further approvals see page 7 Applications Primary standard for the calibration of differential

More information

A brief guide for identification of non-compliant construction machinery. Is this. Compactor / Roller compliant with European legislation?

A brief guide for identification of non-compliant construction machinery. Is this. Compactor / Roller compliant with European legislation? A brief guide for identification of non-compliant construction machinery Is this Compactor / Roller compliant with European legislation? Introduction Construction equipment placed on the EU market for

More information

Inline Flow meter for compressed air and gases DN15 (1/2 ) - DN80 (3 )

Inline Flow meter for compressed air and gases DN15 (1/2 ) - DN80 (3 ) EE771/EE772 Inline Flow meter for compressed air and gases DN15 (1/2 ) - DN80 (3 ) The inline flow meter EE771/EE772, based on the measurement principle of thermal mass flow, is ideally suited for the

More information

Certificate: / 22 March 2013

Certificate: / 22 March 2013 Test report: 936/21215448/A of 11 October 2012 Initial certification: 05 March 2013 Expiry date: 04 March 2018 Publication: BAnz AT 05 March 2013 B10, chapter II, No. 2.4 Approved application The tested

More information

Description Models & Options

Description Models & Options TATSUNO-BEN Č EUROPE A.S. SH AR K B M P500.S - E CON OMY Description Models & Options Distributed by: TATSUNO-BEN Č EUROPE a.s.. Pražská 2325/68 67801 Blansko Česká republika Tel: +420 516428411 Fax: +420

More information

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw Air-to-Water Reverse Cycle Heat Pumps SLH 1202 to 3804 With Screw Compressors 261 to 775 kw 287 to 853 kw Technical Brochure TM SLH-A.2GB Date : November 2004 Supersedes : TM SLH-A.1GB/05.04 Design Features

More information

Flanged resistance thermometer Model TR10-F, with fabricated thermowell model TW40

Flanged resistance thermometer Model TR10-F, with fabricated thermowell model TW40 Electrical temperature measurement Flanged resistance thermometer Model TR10-F, with fabricated thermowell model TW40 WIKA data sheet TE 60.06 for further approvals see page 6 Applications Machine building,

More information

Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L

Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L Temperature Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L WIKA data sheet TE 60.12 for further approvals see page 2 Applications Chemical industry Petrochemical

More information