2668CE CHI CHI CE CE CHI CHI VE VGHI44

Size: px
Start display at page:

Download "2668CE CHI CHI CE CE CHI CHI VE VGHI44"

Transcription

1 WOB-L 2668/2688 SERIES MODELS models 2668CE CE CHI CHI CE CE CHI CHI VE VGHI44 Other models based on availability and minimum purchase. 2668CE CE CHI CHI CS CE CE CHI CHI CS TE44/ TGHI44/ VEF VHI VS44 FEATURES 2668 Head design allows easily replaced piston seal Oil-less, non-lube piston and cylinder Permanently lubricated bearings Stainless steel valves Lightweight die cast aluminum components Long-life, high performance piston seal Thin wall, hard-coated aluminum cylinder for maximum heat transfer Twin fans provide cooling air through and around motor and cylinders Dual intake/exhaust manifold system for easy piping Balanced for smooth, low vibration operation 2688 Field service capability Inlet filter Capacitor All wetted aluminum parts treated for corrosion protection from moisture Patented one piece head for fewer parts and reduced leak paths UL Recognized motor and thermal protector, 115v/60Hz models CE/TUV approved, /50Hz models (Consult factory for non-standard models) Kit options: Guards/Capacitor cover/cords Consult factory for custom applications ISO 9001 CERTIFIED

2 2668 & 2688 Series Performance Data MODEL NUMBERS bar PSI bar MAX. CONTINUOUS PRESSURE MAX. INTERMITTENT PRESSURE IN. mbar (gauge) IN. hg mbar (gauge) MAX. VACUUM MAX. RESTART VACUUM 2668CE CE " hg -887 mbar lbs. 6.5 kg 2668CE CE Inches " hg -914 mbar lbs. 6.9 kg 2668CE CE Inches " hg -928 mbar CE CE " hg -935 mbar & 2688 SERIES Pressure & 02

3 2668 & 2688 Series Performance Data MODEL NUMBERS bar PSI bar MAX. CONTINUOUS PRESSURE MAX. INTERMITTENT PRESSURE IN. mbar (gauge) IN. hg mbar (gauge) MAX. VACUUM MAX. RESTART VACUUM 2668CHI CHI " hg -891 mbar lbs. 6.5 kg 2668CHI CHI Inches " hg -911 mbar lbs. 6.9 kg 2668CHI CHI Inches "hg -928 mbar CHI CHI "hg -935 mbar CS CS44 100v-50/60 Hz 2.70 / / / / / / / / v-50/60 Hz 2.70 / / / / / / / / / / 31.1 / / "hg -935 mbar /60/1 3.6 / / / mfd 1385 / & 2688 SERIES Pressure & 03

4 Dimensions ± WIRING DIAGRAM ORIENT SUCH THAT IT CAN BE READ WHEN VIEWED FROM LEAD END A LINE 4X FEMALE INSULATED QUICK DISCONNECTS X 1/4(.250) X FEMALE QUICK CONNECT (.250 X.032 TAB) NOT SHOWN 4X 1/ ± & 2688 SERIES Pressure & 04

5 2688 Series Performance Data MODEL NUMBER bar PSI bar MAX. CONTINUOUS PRESSURE MAX. INTERMITTENT PRESSURE 2688TE44/38 Pressure Only.440 Primary /.380 Secondary Permanent Split Capacitor lbs. 7.3 kg 2688TGHI44/38 Pressure Only.440 Primary /.380 Secondary 220v / 240v Permanent Split Capacitor lbs. 6.8 kg X FEMALE QUICK CONNECT (.250 X.032 TAB) NOT SHOWN 4X 1/ ± & 2688 SERIES Pressure 05

6 2688 Series Performance Data MODEL NUMBER IN. mbar (gauge) IN. hg mbar (gauge) MAX. VACUUM MAX. RESTART VACUUM 2688VEF " hg -982 mbar 29.0" hg -982 mbar - 110/50/ lbs. 6.6 kg 2688VE lbs. 7.4 kg 2688VHI22 220v " hg -982 mbar 220/50/ lbs. 6.6 kg 2688VGHI44 220/240/230v 1.36/1.39/ /39.4/ /1.18/ /35.8/ /.91/ /32.0/ /.66/ /23.2/ /.42/ /15.0/ /.20/ /7.4/ " hg -982 mbar 0"hg 0mbar 220/240-50/ /1 0.7 / 0.8 / / 155 / / 4.1 / / 1480 / lbs. 6.6 kg 2688VS44 100v-50/60Hz 1.32 / / / / / / / / / / / / " hg -982 mbar /60/1 3.1 / / / mfd 1465 / lbs. 7.4 kg X FEMALE QUICK CONNECT (.250 X.032 TAB) NOT SHOWN 4X 1/ ± The information presented in this material is based on technical data and test results of nominal units. It is believed to be accurate and reliable and is offered as an aid to help in the selection of Thomas products. It is the responsibility of the user to determine the suitability of the product for his intended use and the user assumes all risk and liability whatsoever in connection therewith. Thomas Industries does not warrant, guarantee or assume any obligation or liability in connection with this information. NOTE: Models pictured are representative of the series and do not represent a specific model number. Consult factory for detailed physical description. Form No / Gardner Denver Thomas, Inc. All rights reserved & 2688 SERIES 06 Thomas Products Division 1419 Illinois Ave Sheboygan, WI USA Phone: (920) Fax: (920)

2750 SERIES MODELS FEATURES WOB-L. Standard models 2750CE CGHI50. Other models based on availability and minimum purchase.

2750 SERIES MODELS FEATURES WOB-L. Standard models 2750CE CGHI50. Other models based on availability and minimum purchase. WOB-L 2750 SERIES MODELS models 2750CE50 2750CGHI50 Other models based on availability and minimum purchase. 2750CE60 2750CGHI60 2750CS50 2750CS60 2750TGHI48 2750BE75 2750BGHI75 275OBS75 275OVEF75 2750VHI75

More information

WOB-L. PISTON Pumps and Compressors. 607/668/669/688/689 Series MODELS:

WOB-L. PISTON Pumps and Compressors. 607/668/669/688/689 Series MODELS: WOB-L PISTON Pumps and Compressors 607/668/669/688/689 Series MODELS: Standard models available. 607CA22, 607CA32, 607CD22, 607CD32 668CE44, 668CGHI44 688CE44, 688CGHI44 669CE44, 669CHGI44 689CE44, 689CGHI44

More information

1/12, 1/6, 1/4, 1/3, 1/2, 3/4 & 1.0 HP

1/12, 1/6, 1/4, 1/3, 1/2, 3/4 & 1.0 HP Articulating Piston TAskair (TA) Series /, /6, /4, /3, /, 3/4 &.0 HP MODELS TA-0-DC (70046) TA-30-DC (7004) TA-40-DC (7005) TA-40-DC (70047) TA-50-DC (70058) TA-50E (70063) TA-50E (70064) TA-60E (70066)

More information

2755 Series BASE MODELS FEATURES 2755BE75 (115/60/1) 2755BGHI75 (230/601/1 & /50/1) 2755CE60 (115/60/1) 2755CGHI60 (230/601/1 & /50/1)

2755 Series BASE MODELS FEATURES 2755BE75 (115/60/1) 2755BGHI75 (230/601/1 & /50/1) 2755CE60 (115/60/1) 2755CGHI60 (230/601/1 & /50/1) FEATURES > > Monolithic head > > Epoxy coated wetted parts > > 17mm shaft & bearing compliment > > Oil-less operation > > Permanently lubricated bearings > > Stainless steel valves > > Die-cast aluminum

More information

Standard Product Catalog

Standard Product Catalog Standard Product Catalog WOB-L Piston MODEL SERIES Air Compressors & Vacuum Pumps LPM @ PSI (PSI) LPM @ IN.HG. (IN.HG.) VOLTAGE TYPE* 0 5 10 20 40 60 80 100 CONTINUOUS INTERMITTENT RESTART 0 5 10 15 20

More information

7010 Series FEATURES BASE MODEL TYPICAL APPLICATIONS. Diaphragm. > > Oil-less > > Low vibration > > Low sound level

7010 Series FEATURES BASE MODEL TYPICAL APPLICATIONS. Diaphragm. > > Oil-less > > Low vibration > > Low sound level 71 Series FEATURES > > Oil-less > > Low vibration > > Low sound level BASE MODEL 71 DC 71 AC 71Z DC 71Z AC TYPICAL APPLICATIONS > > Medical devices > > Clinical analyzers > > Air collector > > Inhalators

More information

8011 Series FEATURES BASE MODEL TYPICAL APPLICATIONS. Diaphragm

8011 Series FEATURES BASE MODEL TYPICAL APPLICATIONS. Diaphragm 811 Series FEATURES > > > > Maintenance free > > Low sound level > > Low vibration > > High performance BASE MODEL 811 AC 811Z AC TYPICAL APPLICATIONS > > Autoclaves > > Analysers > > Vacuum ovens > >

More information

COMPRESSORS, VACUUM & LIQUID PUMPS Global Solutions

COMPRESSORS, VACUUM & LIQUID PUMPS Global Solutions COMPRESSORS, VACUUM & LIQUID PUMPS Global Solutions INTRODUCTION / TABLE OF CONTENTS Pump and Compressor Solutions for OEMs Worldwide As the leader in providing fluidic solutions to Original Equipment

More information

Improving Lives through Innovation TM. Global Catalog. Compressors, Vacuum Pumps & Liquid Pumps

Improving Lives through Innovation TM. Global Catalog. Compressors, Vacuum Pumps & Liquid Pumps Improving Lives through Innovation TM Global Catalog Compressors, Vacuum Pumps & Liquid Pumps Pumps and Compressor Solutions for OEMs Worldwide As a leader in providing fluidic solutions to Original Equipment

More information

7006 Series FEATURES BASE MODEL TYPICAL APPLICATIONS. Diaphragm. > > Oil-less > > Low vibration > > Low sound level

7006 Series FEATURES BASE MODEL TYPICAL APPLICATIONS. Diaphragm. > > Oil-less > > Low vibration > > Low sound level 76 Series FEATURES > > Oil-less > > Low vibration > > Low sound level TYPICAL APPLICATIONS BASE MODEL 76 DC 76 AC 76 BLDC 76Z DC 76Z AC 76Z BLDC > > Medical devices > > Clinical analyzers > > Air collector

More information

3003 Series FEATURES BASE MODEL TYPICAL APPLICATIONS. Diaphragm. >>Oil-less. >>Low vibration. >>Low sound level. >>Compact design >>Lightweight

3003 Series FEATURES BASE MODEL TYPICAL APPLICATIONS. Diaphragm. >>Oil-less. >>Low vibration. >>Low sound level. >>Compact design >>Lightweight 33 Series FEATURES BASE MOEL >>Oil-less 33 C >>Low vibration 33 LC >>Low sound level 33 BLC >>Compact design >>Lightweight TYPICAL APPLICATIONS >>Patient monitoring >>Anaesthetic control >>Gas detection

More information

AP LP LW YP YP-DU Series

AP LP LW YP YP-DU Series AP LP LW YP YP-DU Series FEATURES > > Oil-less > > Long life > > Low power consumption > > Worldwide service network > > Low sound level/vibration > > Protection class IP54 (AP/LP/LW-Series) > > CE approved

More information

5002F Series FEATURES BASE MODEL TYPICAL APPLICATIONS. Diaphragm

5002F Series FEATURES BASE MODEL TYPICAL APPLICATIONS. Diaphragm 52F Series FEATURES > > Self priming > > Dry running > > Oil-less, non lubricated > > Suitable for continuous operation > > Chemical resistant pump materials for aggressive media BASE MODEL 52F 52F Twin

More information

STANDARD PRODUCT CATALOG

STANDARD PRODUCT CATALOG STANDARD PRODUCT CATALOG Pumps and Compressor Solutions for OEMs Worldwide As the longtime leader in pressure and vacuum products for the OEM market, Thomas draws on nearly 50 years of technological strength.

More information

J 6 Se r i e s. Pressure and Vacuum switches. features

J 6 Se r i e s. Pressure and Vacuum switches. features J 6 S er i es J 6 Se r i e s Pressure and Vacuum switches features Gasketed, Die Cast Aluminum Enclosure with Epoxy Coating SPDT Switch Output Adjustable Deadband Option Sealed, Isolated Metal Bellows

More information

E. Clark & Associates 10 Brent Drive Hudson, MA Tel. 978 / Fax 978 / Two Switch Output Hex Screw Adjustment

E. Clark & Associates 10 Brent Drive Hudson, MA Tel. 978 / Fax 978 / Two Switch Output Hex Screw Adjustment CLARK SOLUTIONS 400 Series, Pressure, Vacuum, Diff. Pressure & Temp. Switches 1,2 & 3 Switch output, Adjustable Ranges 30 Vac to 6000 PSI, -180 to 650 o F DESCRIPTION The 400 Series is a versatile family

More information

MODIFICATIONS AVAILABLE - MADE TO ORDER - CONSULT OUR FACTORY. (MINIMUM ORDER MAY BE REQUIRED.)

MODIFICATIONS AVAILABLE - MADE TO ORDER - CONSULT OUR FACTORY. (MINIMUM ORDER MAY BE REQUIRED.) NEEDLE VALVES - ANGLE & CROSS PATTERN Flow can be accurately controlled from full orifice opening to shut off. Fluid flow is readily visible through large sight window. Cross pattern can be used singularly

More information

FCX TECHNICAL BOOKLET

FCX TECHNICAL BOOKLET FAN COIL FCX US FCX USPO This document is based on AERMEC s FCX US, USP, USPO Technical and Installa on Booklet but reflects only those sizes and configura ons currently offered by Phoenix Energy Supply.

More information

STANDARD PRODUCT CATALOGUE EUROPE

STANDARD PRODUCT CATALOGUE EUROPE STANDARD PRODUCT CATALOGUE EUROPE Vacuum/Pressure & Liquid to 365 l/min Market driven engineering For pumps and compressors, Thomas is the right contact. We understand our customers requirements: quiet

More information

Dissolved Oxygen Measurement System with Air Blast Cleaner

Dissolved Oxygen Measurement System with Air Blast Cleaner Product Data Sheet PDS 71-DO-03/04/rev.D August 2004 MODEL DO -03/-04 Dissolved Oxygen Measurement System with Air Blast Cleaner COMPLETE SYSTEM INCLUDES sensor, analyzer, sensor washer head, mounting

More information

Max. oil content of compressed air

Max. oil content of compressed air 1 Version Control Certificates Ambient temperature min./max. Medium temperature min./max. Medium Poppet valve Analog CE declaration of conformity +32 F / +15 F +32 F / +15 F Compressed air 0012533 Max.

More information

MB Series AC Centrifugal Blowers

MB Series AC Centrifugal Blowers MB Series AC Centrifugal Blowers Impeller Diameter 6.3 in. dia. ( 16 mm) SAFETY STD. AC INPUT Specifications c Materials Motor Case: Casing: Impeller: Aluminum Voltage Frequency Current Input Power Max.

More information

VAL-AIR AIR COMPRESSORS

VAL-AIR AIR COMPRESSORS VAL-AIR AIR COMPRESSORS All Val-Air Compressors are virtually soundless and are totally automatic. Each unit includes a tank pressure gauge, line pressure gauge, line pressure regulator, moisture trap/filter,

More information

HIGH PRESSURE AIR COMPRESSOR SYSTEM MODEL #: 091-9HP-220 INPUT:

HIGH PRESSURE AIR COMPRESSOR SYSTEM MODEL #: 091-9HP-220 INPUT: INSTRUCTION MANUAL AUTO-PUMP HP 240 VAC HIGH PRESSURE AIR COMPRESSOR SYSTEM MODEL #: 091-9HP-220 INPUT: 220-240 Vac, 50 Hz, 1.3 Amps 230 Vac, 60 Hz, 1.2 Amps File: IM_091-9HP-220-RevB2.indd Rev: B2 Revised

More information

Product Data. FS3QX Slim Line Ducted Fan Coil With Plenum Sizes 018 thru 060 SLIM LINE DUCTED FAN COIL WITH PLENUM ON/OFF DISPLAY TEMP

Product Data. FS3QX Slim Line Ducted Fan Coil With Plenum Sizes 018 thru 060 SLIM LINE DUCTED FAN COIL WITH PLENUM ON/OFF DISPLAY TEMP FS3QX Slim Line Ducted Fan Coil With Plenum Sizes 018 thru 060 Product Data A114 SLIM LINE DUCTED FAN COIL WITH PLENUM Installation Ease S Factory installed 24 volt transformer and relay S High and low

More information

Crack Sealing Industry Piercing Tool Manufacturers Paint Striping Manufacturers Vacuum Excavation F

Crack Sealing Industry Piercing Tool Manufacturers Paint Striping Manufacturers Vacuum Excavation F Crack Sealing Industry Piercing Tool Manufacturers Paint Striping Manufacturers Vacuum Excavation F ire Truck Manufacturers Our reliability. Your profits. Embracing over 25 years in the air compressor

More information

Pump Specifications 405 Series Commercial Drain Pump (High-Temp)

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 405_P1 R8/22/2017 Copyright 2017 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice. 405-Series Dimensional

More information

5 15 HP QUIET ENCLOSED RECIPROCATING AIR COMPRESSORS. Paradigm

5 15 HP QUIET ENCLOSED RECIPROCATING AIR COMPRESSORS. Paradigm 5 15 HP QUIET ENCLOSED RECIPROCATING AIR COMPRESSORS Paradigm GARDNER DENVER PARADIGM Engineered Excellence Ultimate Performance A Winning Combination Gardner Denver compressors are proven units, known

More information

IST INTELLIGENT SUBMERSIBLE TURBINE

IST INTELLIGENT SUBMERSIBLE TURBINE INTELLIGENT SUBMERSIBLE TURBINE IST The FIRST Submersible Pump Ever Designed For High Volume Retailers. The NEW 4HP 4" Diameter Variable Speed Turbine. When FAST Fueling Means MORE Sales. THE IST... NOW

More information

Material required for drilled well application (indoor use only)

Material required for drilled well application (indoor use only) SAFETY INSTRUCTIONS: This fine pump that you have just purchased is designed from the latest in material and workmanship. Before installation and operation, we recommend the following procedures: A B C

More information

SECTION MOTOR REQUIREMENTS for HVAC

SECTION MOTOR REQUIREMENTS for HVAC PART 1 GENERAL 1.1 SECTION INCLUDES A. Single-phase electric motors B. Three-phase electric motors 1.2 REFERENCES SECTION 23 05 13 MOTOR REQUIREMENTS for HVAC A. ABMA 9 - Load Ratings and Fatigue Life

More information

POSITIVE DISPLACEMENT BLOWER PACKAGES. IQ Family

POSITIVE DISPLACEMENT BLOWER PACKAGES. IQ Family POSITIVE DISPLACEMENT BLOWER PACKAGES IQ Family It s all about the Experience A trusted & reliable brand, ensuring that you have the right blower package for the job A REPUTATION EARNED BY A PROVEN HISTORY

More information

BGD278 Series BASOTROL CE Approved Gas Valve

BGD278 Series BASOTROL CE Approved Gas Valve Product Bulletin Issue Date November 16, 2012 BGD278 Series BASOTROL CE Approved Gas Valve The BGD278 Series gas valve is a combination main and pilot valve intended for use in conjunction with solid-state

More information

SECTION COMMON MOTOR REQUIREMENTS FOR HVAC EQUIPMENT

SECTION COMMON MOTOR REQUIREMENTS FOR HVAC EQUIPMENT SECTION 230513 - COMMON MOTOR REQUIREMENTS FOR HVAC EQUIPMENT PART 1 GENERAL 1.1 SECTION INCLUDES A. Single phase electric motors. B. Three phase electric motors. 1.2 REFERENCE STANDARDS A. ABMA STD 9

More information

Protection against mechanical impacts IK 08 according to IEC 68, EN Insulation class Class F (155 C), class H (180 C) on request.

Protection against mechanical impacts IK 08 according to IEC 68, EN Insulation class Class F (155 C), class H (180 C) on request. MVSI The MVSI series represents the line of reference products for manufacturer s of vibrating machines and plants operating in many industrial sectors and is made up of the largest range on the market,

More information

APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R-410A and R-22 SYSTEMS

APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R-410A and R-22 SYSTEMS FSA Product Specifications APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R-410A and R-22 SYSTEMS 1½ THRU 3 TONS FEATURES TXV metering device factory installed

More information

Palmer Circular Chart Recorders

Palmer Circular Chart Recorders Palmer Circular Chart Recorders Pressure & Temperature Recorders Designed for indoor or outdoor use, our recorders provide long service life, even in harsh conditions. Internal Assemblies, Clocks and Parts

More information

BGD258 Series BASOTROL CE Approved Class A Gas Valve

BGD258 Series BASOTROL CE Approved Class A Gas Valve Product Bulletin Issue Date May 21, 2010 BGD258 Series BASOTROL CE Approved Class A Gas Valve The BGD258 Series multi-function gas control valve works in conjunction with an electronic sequence control

More information

M-100 Adjustable flow switch with right-angle flow

M-100 Adjustable flow switch with right-angle flow M-100 Adjustable flow switch with right-angle flow Operating Instructions and Quick Start Guide Table of Contents Introduction 03 Operation 03 Storage and Handling 03 Installation Instruction 03 Specification

More information

APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R -22 SYSTEMS

APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R -22 SYSTEMS COMMERCIAL FSA Product Specifications APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R -22 SYSTEMS 1½ THRU 3 TONS FEATURES S TXV metering device factory installed

More information

10 S e r i e s PRESSURE SWITCH. features

10 S e r i e s PRESSURE SWITCH. features 10 S er i es 10 S e r i e s PRESSURE SWITCH features Tamper-Resistant Field Adjustment Adjustable Ranges from 4 to 7500 PSI (0,3 to 517,1 Bar) Choice of 7 Electrical Terminations 1-1/4" Diameter Height

More information

A-C Capacitors for Motor Run Applications

A-C Capacitors for Motor Run Applications CPD 510 03 / 08 A-C Capacitors for Motor Run Applications Capacitor Application Data Sheet To ensure correct selection of a capacitor for your application, please provide the information indicated below.

More information

See Note. 100% of rated load. Mechanical efficiency ISO3046/1 2,4,7 35.2% 34.8% 34.1% Electrical efficiency ISO3046/1 2,4,6,7 33.7% 33.4% 32.

See Note. 100% of rated load. Mechanical efficiency ISO3046/1 2,4,7 35.2% 34.8% 34.1% Electrical efficiency ISO3046/1 2,4,6,7 33.7% 33.4% 32. Generator set data sheet 1000 kw (1250 kva) Standby Model: C1000 N6 Frequency: 60 Hz Fuel type: Natural gas MI 50 + Emissions NOx: 1.0 g/hp-hr LT water inlet temp: 50 C (122 F) HT water outlet temp: 90

More information

See Note. 100% of rated load

See Note. 100% of rated load Generator set data sheet 1250 kw (1563 kva) Standby Model: C1250 N6 Frequency: 60 Hz Fuel type: Natural gas MI 69 + Emissions NOx: 1.0 g/hp-hr LT water inlet temp: 50 C (122 F) HT water outlet temp: 90

More information

VIKING HG SERIES HELICAL GEAR EXTERNAL GEAR PUMPS

VIKING HG SERIES HELICAL GEAR EXTERNAL GEAR PUMPS Page 350.1 Series Description Viking s HG series positive displacement pumps are designed to provide low noise transfer and processing of clean, lubricating liquids for applications such as lube oils,

More information

Max. particle size 50 µm Max. oil content of compressed air

Max. particle size 50 µm Max. oil content of compressed air 1 Version Poppet valve Control Analog Certificates CE declaration of conformity Ambient temperature min./max. +0 C / +70 C Medium temperature min./max. +0 C / +70 C Medium Compressed air Max. particle

More information

SUBMERSIBLE PUMPING SYSTEMS SUBMERSIBLE TURBINE PUMPS

SUBMERSIBLE PUMPING SYSTEMS SUBMERSIBLE TURBINE PUMPS Variable Speed Submersible Turbine Pumps Introduced in 1995, FE Petro brand variable speed submersible turbine pumps (STPs) were the first of their kind for the petroleum equipment industry. With faster

More information

FADE SERIES. Typical Specifications for Model FADE Sidewall Propeller Fans Sidewall propeller fans shall be of the direct driven type.

FADE SERIES. Typical Specifications for Model FADE Sidewall Propeller Fans Sidewall propeller fans shall be of the direct driven type. January 2008 FADE0108 Fantech, Inc. certifies that the FADE Series shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA

More information

AUTO-PUMP 120 VAC AIR COMPRESSOR SYSTEM INSTRUCTION MANUAL. 170 Cherry Avenue West Sayville, NY

AUTO-PUMP 120 VAC AIR COMPRESSOR SYSTEM INSTRUCTION MANUAL. 170 Cherry Avenue West Sayville, NY INSTRUCTION MANUAL AUTO-PUMP 120 VAC AIR COMPRESSOR SYSTEM MODEL #: #:091-9B-1 091-9B-1 INPUT :120 volt, 50/60 Hz, 1.8 AMPS OUTPUT: 100 PSI MAXIMUM File: 091-9B-1_revA1_GEN3 Rev: A1 Revised By:PSS/JRN

More information

AC centrifugal fan. forward-curved, single-intake with housing (flange)

AC centrifugal fan. forward-curved, single-intake with housing (flange) GE8-AA- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen Amtsgericht (court of

More information

AC axial fans, AC diagonal fans

AC axial fans, AC diagonal fans fans, C diagonal fans Technology ccessories EC-SYSTEMS ESM General information K series Q-motor EC axial EC axial fans series fans fans Ø 130 - Ø 250 14 C diagonal fans Ø 208 20 13 Contacts fans Ø 130

More information

PMC-MC-X2-Chassis PMC-MC-X4-Chassis

PMC-MC-X2-Chassis PMC-MC-X4-Chassis DYNAMIC ENGINEERING 150 DuBois St Suite 3, Santa Cruz Ca 95060 831-457-8891 Fax 831-457-4793 http://www.dyneng.com sales@dyneng.com Est. 1988 User Manual Four Slot Carrier Two Slot Carrier PMC-MC-X2-Chassis

More information

VACUUM PUMP. Please read the operating manual carefully before using.

VACUUM PUMP. Please read the operating manual carefully before using. Operating Manual 231672 Please read the operating manual carefully before using. I. Pump components Oil Fill Cap Handle Inlet Fitting Exhaust Fitting Power Switch Sight Glass Fan Cover Die-Cast Aluminum

More information

Cooling Fans MU Series 119 mm 38 mm Thick ( 4.69 in. 1. in. Thick) Ambient Temperature: 1 + C (+14 +14 F) Operating Voltage Range: ±1% Materials Frame: Die Cast Aluminum Blades: Polycarbonate (Flammability

More information

Sc h rader Bellows. CS Series Air Control Valves. 2 & 3-Way, Inline, Manifold & Stacking Direct Acting Solenoid Valves

Sc h rader Bellows. CS Series Air Control Valves. 2 & 3-Way, Inline, Manifold & Stacking Direct Acting Solenoid Valves Sc h rader Bellows 2 & 3-Way, Inline, Manifold & Stacking Direct cting Solenoid Valves INDEX PGE Features Inline Valves... 3 Stacking Valves... 4 Manifold Valves... 5 Valve Model Number System... 6 Solenoid

More information

INSTRUCTION MANUAL FOR LINEAR COMPRESSORS

INSTRUCTION MANUAL FOR LINEAR COMPRESSORS CONTENTS INSTRUCTION MANUAL FOR LINEAR COMPRESSORS MODEL EL-60 EL-10W EL-80-15 EL-150 EL-80-17 EL-00 EL-100 1. Parts name. Instructions -1 Prior to operation 3 - Storage and transfer 3-3 Installation 4

More information

Sl. No. Description Pages

Sl. No. Description Pages Sl. No. Description Pages A. B. UL & ISO Certificate List of General 1) General Description 2-3 2) Major components of Deluge Valve 4-5 3) Trim Description 5 6-8 4) Technical Data 9 5) DV Assembly Outside

More information

VGD Series VGDxx.xxxU Gas Valves for use with SKPxx.xxxU electro hydraulic actuators

VGD Series VGDxx.xxxU Gas Valves for use with SKPxx.xxxU electro hydraulic actuators VGD Series VGDxx.xxxU Gas Valves for use with SKPxx.xxxU electro hydraulic actuators Technical Instructions Document No. 7631 VGDxx.xxxU VGD20.xxxU VGD40.xxxU ISO 9001 and 14000 REGISTERED FIRM Only with

More information

MODEL SS INSTALLATION INSTRUCTIONS

MODEL SS INSTALLATION INSTRUCTIONS WWW.BURCAM.COM 2190 Boul. Dagenais West TEL: 514.337.4415 LAVAL (QUEBEC) FAX: 514.337.4029 CANADA H7L 5X9 info@burcam.com Your pump has been carefully packaged at the factory to prevent damage during shipping.

More information

6/2 ways/positions flow diverters L (VS120-VS125-VS129)

6/2 ways/positions flow diverters L (VS120-VS125-VS129) 6/2 ways/positions flow diverters L710... VS120-VS125-VS129) RE 18302-04 Edition: 05.2014 Replaces: 07.12 Size 4 Series 00 Maximum operating pressure 310 bar 4500 psi) Maximum flow 25 l/min 6.6 gpm) Ports

More information

Installation, Operation, Repair and Parts Manual

Installation, Operation, Repair and Parts Manual Self-Priming Adaptor Form L-1516 (3-08) Installation, Operation, Repair and Parts Manual Description Self-priming adaptor (SPA) is a low pressure tank that provides air separation from the liquid being

More information

AC Leak Freeze AIR CONDITIONING. AC Leak Freeze permanently seals leaks in air conditioning and refrigeration systems

AC Leak Freeze AIR CONDITIONING. AC Leak Freeze permanently seals leaks in air conditioning and refrigeration systems AC Leak Freeze AC Leak Freeze permanently seals leaks in air conditioning and refrigeration systems Will continue to seal additional Leaks for up to 1 year that meet testing specifications Does not contain

More information

SECTION METERS AND GAUGES FOR HVAC PIPING

SECTION METERS AND GAUGES FOR HVAC PIPING SECTION 23 05 19 METERS AND GAUGES FOR HVAC PIPING PART 1 - GENERAL 1.1 SUMMARY A. Work included: Provision of materials, installation and testing of: 1. Thermometers 2. Thermometer Wells 3. Differential

More information

Aerovox Corp. Capacitors for HID Lighting Applications. Catalog HID-cap 2004-R0

Aerovox Corp. Capacitors for HID Lighting Applications. Catalog HID-cap 2004-R0 Aerovox Corp. Capacitors for HID Lighting Applications Catalog HID-cap 2004-R0 Table of Contents Introduction...3 Quality Assurance...3 Applications...4 Agency Listings...4 of Aerovox Capacitors:...4 Safety

More information

Technical Sales Guide # 040 YDFC 0 1 Page 2

Technical Sales Guide # 040 YDFC 0 1 Page 2 17-18 Technical Sales Guide # 040 YDFC 0 1 Page 2 Technical Sales Guide # 040 YDFC 0 1 Page 3 York China Fan Coil Unit Model Type ST - Standard DC - District Cooling Number of rows 3: 3 Rows 4: 4 Rows

More information

3 Automotive Structural Adhesives

3 Automotive Structural Adhesives Automotive Structural Adhesives TM Scotch-Grip Fastener Adhesives 2, 4844 (Normal Temp Formula) Data Sheet June 2 General Description M Scotch-Grip TM Fastener Adhesives are microencapsulated, room temperature

More information

12-VOLT PUMPS CHOOSING A GPI ELECTRIC GEAR PUMP

12-VOLT PUMPS CHOOSING A GPI ELECTRIC GEAR PUMP 12-VOLT S CHOOSING A GPI ELECTRIC GEAR When it comes to choosing an Electric Pump, GPI makes it easy! At Great Plains Industries, we recognize the differences in the needs of our customers. EZ-8 137100-01

More information

Precision TIG 375. The Power To Perform! Advantage Lincoln TIG WELDERS. Output. Input 1 PHASE. Publication E /05

Precision TIG 375. The Power To Perform! Advantage Lincoln TIG WELDERS. Output. Input 1 PHASE. Publication E /05 TIG WELDERS Precision TIG 375 The Power To Perform! The Precision TIG TM 375 delivers the Power to Perform setting a new standard in Square Wave Technology. Combining outstanding value-added features and

More information

LF-72 and LF-74 Wire Feeders

LF-72 and LF-74 Wire Feeders SEMIAUTOMATIC WIRE FEEDERS LF-72 and LF-74 Wire Feeders 2-Roll or 4-Roll Heavy Duty Industrial Feeders Designed for MIG and cored wire welding in job shop and manufacturing environments, the rugged LF-72

More information

3-Phase Military AC-DC Power Supply 3-Phase, VrmsL-L

3-Phase Military AC-DC Power Supply 3-Phase, VrmsL-L -4-1U 3-Phase Military AC-DC Power Supply 3-Phase, 8-265 VrmsL-L 47-8 Hz Semi-Regulated 28 V-48 V 4 W 525 W Transient Input Power Input Frequency Output Voltages Output Power Sealed Construction, Ultra

More information

FIXED SPEED SUBMERGED TURBINE PUMPS STP

FIXED SPEED SUBMERGED TURBINE PUMPS STP FIXED SPEED SUBMERGED TURBINE PUMPS STP MagShell SETS A NEW STANDARD FOR SUBMERSIBLE PUMP PERFORMANCE SUBMERGED TURBINE PUMPS Since the mid 190 s, FE Petro s parent company, Franklin Electric, has been

More information

A Compact, Liquid-Cooled Variable Speed Drive for High Horsepower Applications

A Compact, Liquid-Cooled Variable Speed Drive for High Horsepower Applications A Compact, Liquid-Cooled Variable Speed Drive for High Horsepower Applications The Reliance Electric LiquiFlo AC drive combines high-performance variable speed drive technology with a patented liquid-cooling

More information

REPLACEMENT MOTORS for Refrigeration Applications

REPLACEMENT MOTORS for Refrigeration Applications REPLCEMENT MOTORS for Refrigeration pplications Innovative Brands from Regal Smarter. Stronger. Cooler. PPLICTIONS CONVENIENCE STORE B B C B C Display Case Soda Vending Machine (outside) Ice Freezer (outside)

More information

MINA-GEAR GEARMOTORS P-1. Mina-Gear Features... P-2 Application & Selection... P-3 Right-Angle Worm Gearmotors Series Parallel Shaft Gearmotors

MINA-GEAR GEARMOTORS P-1. Mina-Gear Features... P-2 Application & Selection... P-3 Right-Angle Worm Gearmotors Series Parallel Shaft Gearmotors MINA-GEAR GEARMOTORS Mina-Gear..................................................... -2 Application & Selection................................................... -3 Right-Angle Worm Gearmotors 2100 Series

More information

G100U MODEL STANDARD FEATURES GENERATOR RATINGS CONDITIONS OF SALE. General features :

G100U MODEL STANDARD FEATURES GENERATOR RATINGS CONDITIONS OF SALE. General features : G100U MODEL Stand-by Power @ 60Hz Prime Power @ 60Hz G100U 80-100 kw /80-5 kva 71-94 kw / 71-118 kva GAS GENSET STANDARD FEATURES General features : SDMO Industries provides one-source responsibility for

More information

NEW! BOOSTER PUMPS. HBP/HBPS series 4" horizontal booster pumps. booster pumps

NEW! BOOSTER PUMPS. HBP/HBPS series 4 horizontal booster pumps. booster pumps HBP/HBPS series 4" horizontal The HBP/HBPS Series Booster Pumps are the most durable available. The patented SignaSeal floating impeller design minimizes thrust loads, allowing for continuous operation

More information

Sil-Air Compressors. SIL-AIR 50-6 ½ HP, 1.5 Gal Tank 2.15 CFM Free Air PSI Op-Pressure Shipping Weight: 55lbs Voltage: 110 V-60

Sil-Air Compressors. SIL-AIR 50-6 ½ HP, 1.5 Gal Tank 2.15 CFM Free Air PSI Op-Pressure Shipping Weight: 55lbs Voltage: 110 V-60 Sil-Air Compressors Sil-Air Compressors are virtually soundless and totally automatic. Each unit includes a tank pressure gauge, line pressure gauge, line pressure regulator, moisture trap/filter, safety

More information

INSTRUCTION MANUAL AUTO-PUMP 220/240 VAC MODEL #091-9B-220. INPUT :220/240 volt, 50/60 Hz, 1.9/2.2 AMPS OUTPUT: 100 PSI MAXIMUM 1 YEAR WARRANTY

INSTRUCTION MANUAL AUTO-PUMP 220/240 VAC MODEL #091-9B-220. INPUT :220/240 volt, 50/60 Hz, 1.9/2.2 AMPS OUTPUT: 100 PSI MAXIMUM 1 YEAR WARRANTY BOOK# 091-9B-220 4-18-2002 INSTRUCTION MANUAL AUTO-PUMP 220/240 VAC AIR COMPRESSOR SYSTEM MODEL #091-9B-220 INPUT :220/240 volt, 50/60 Hz, 1.9/2.2 AMPS OUTPUT: 100 PSI MAXIMUM 1 YEAR WARRANTY KUSSMAUL

More information

DD25B. Volvo Double Drum Compactors 2.6 t 18.5 kw

DD25B. Volvo Double Drum Compactors 2.6 t 18.5 kw DD25B Volvo Double Drum Compactors 2.6 t 18.5 kw 360 visibility With an optimally positioned sliding seat, angled drum mounts and a sloping hood design, the DD25B provides industry-leading, all-around

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS www.burcam.com 2190 Dagenais Blvd.West TEL: 514.337.4415 LAVAL (QUEBEC) FAX: 514.337.4029 CANADA H7L 5X9 info@burcam.com INSTALLATION INSTRUCTIONS MODEL 506518SS AND BY-PRODUCTS LIKE Your pump has been

More information

P66 Series Electronic Fan Speed Controls

P66 Series Electronic Fan Speed Controls FANs 125, 121 Pressure Controls Section P Product/Technical Bulletin P66 Issue Date 0498 P66 Series Electronic Fan Speed Controls The P66 is a pressure actuated electronic motor speed controller. This

More information

Electric Chain Hoists Enhanced Features. UL Listed* Green Initiative. Easy Access Suspension. Notched Hook and Latch System. Unique Load Sheave

Electric Chain Hoists Enhanced Features. UL Listed* Green Initiative. Easy Access Suspension. Notched Hook and Latch System. Unique Load Sheave Electric Chain Hoists Enhanced Features UL Listed* Certified and listed to UL 1340 Standard for Hoists. Green Initiative Built smarter without the use of harmful materials. Environmentally friendly. RoHS

More information

4-in-1 MOTORS ONE SIMPLE CONNECTION

4-in-1 MOTORS ONE SIMPLE CONNECTION 4-in-1 MOTORS 4-IN-1 MULTI-HORSEPOWER MOTORS Class B Insulation 60 C (140 F) Max Ambient FEATURES UL/CSA approved Class B insulation All-angle mount Energy-efficient PSC design Lead length 36 to 48 Reversing

More information

Product details are described at websites

Product details are described at websites ~~~ Starting in 1922, Aerovox continues as the leading producer of film capacitors for AC voltage applications. After being acquired by Provident Industries in 2002, Aerovox joined with Parallax Power

More information

VSO - MI thermally compensated proportional valve

VSO - MI thermally compensated proportional valve The VSO - MI is a miniature proportional valve specifically designed for medical device manufacturers and incorporates thermal compensation to provide precise flow control and stability over a wide operating

More information

Table of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10

Table of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10 Table of Contents Page No. 1. Model Designation And Unit Models 1 2. Features 2 3. Guide Specifications 4 4. Standard Unit Components 5 5. Technical Data 6 6. Performance Data 10 7. Electrical Data 19

More information

THE INSIDE STORY OF THE QPV OR MPV:

THE INSIDE STORY OF THE QPV OR MPV: BRQPVMPV0305E THE INSIDE STORY OF THE QPV OR MPV: Access Hole Permits Field Adjustments Electronic Control Circuit Available in a Wide Range of Electrical Control Inputs and Analog Outputs Many Connector

More information

- 20k psi. Powerful Hand-held Rotary Nozzles MODEL MAX. PRES. MAX. FLOW LENGTH DIAMETER INLET JETS

- 20k psi. Powerful Hand-held Rotary Nozzles MODEL MAX. PRES. MAX. FLOW LENGTH DIAMETER INLET JETS Barracuda - 20k psi Powerful Hand-held Rotary Nozzles Barracuda Shotgun Nozzle 20k psi models The Barracuda sinks its teeth into tough cleaning jobs. Our leak-free seal design combined with centrifugal

More information

AH / AV. Advanced Series Unit Heaters AH / AV. Ruffneck

AH / AV. Advanced Series Unit Heaters AH / AV. Ruffneck The Ruffneck Advanced Series heaters are designed for rugged industrial applications and are available in 37 models from 6,000 to 1,,000 Btu/hr With a maximum operating pressure and temperature rating

More information

See Note. 100% of rated load

See Note. 100% of rated load Generator set data sheet 1400 kw Continuous Model: C1400 N6C Frequency: 60 Hz Fuel type: Natural gas MI 75 + Emissions NOx: 1.0 g/hp-hr LT water inlet temp: 50 C (122 F) HT water outlet temp: 90 C (194

More information

See Note. 100% of rated load

See Note. 100% of rated load Generator set data sheet 1160 kw Continuous Model: Frequency: C1160 N5C 50 Hz Fuel type: Natural gas MI 78 + Emissions NOx: 500 mg/nm 3 LT water inlet temp: HT water outlet temp: 50 C (122 F) 95 C (203

More information

Section J Air Control Nozzles

Section J Air Control Nozzles Section J Overview Our extensive line of air control nozzles, used in drying and blowing applications, includes products that use regenerative blowers and products that require compressed air. WindJet

More information

See Note. 100% of rated load

See Note. 100% of rated load Generator set data sheet 2000 kw Continuous Model: C2000 N6C Frequency: 60 Hz Fuel type: Natural gas MI 76 + Emissions NOx: 0.5 g/hp-h LT water inlet temp: 50 C (122 F) HT water outlet temp: 92 C (198

More information

Electric Actuated Ball Valves 150# Flanged Stainless Steel, Full Port 1/2 to 4 inch Pipe

Electric Actuated Ball Valves 150# Flanged Stainless Steel, Full Port 1/2 to 4 inch Pipe 1/2 to 4 inch Pipe Features Direct mount ISO5211 Full Port stainless steel ball valve 2-piece ANSI Class 150 flanged body 275 PSI working pressure at 100 F (38 C) Highly visual dome style valve position

More information

McGUIRE AIR COMPRESSORS HP RECIPROCATING AIR COMPRESSORS. R-Series. McGUIRE AIR COMPRESSORS

McGUIRE AIR COMPRESSORS HP RECIPROCATING AIR COMPRESSORS. R-Series. McGUIRE AIR COMPRESSORS 2 30 RECIPROCATING AIR COMPRESSORS R-Series CHAMPION R-SERIES Customized Solutions Unparalleled Performance A Winning Combination Champion compressors are proven units, known for their reliability over

More information

Compact Electric Actuated Ball Valves PVC Body, Teflon/EPDM Seals 1/2 to 1 inch Pipe

Compact Electric Actuated Ball Valves PVC Body, Teflon/EPDM Seals 1/2 to 1 inch Pipe Compact Electric Actuated Ball Valves PVC Body, Teflon/EPDM Seals 1/2 to 1 inch Pipe SERIES Features Industrial quality miniature actuator Industrial grade True Union ball valve Visual valve position indicator

More information

GENERAL SPECIFICATIONS AND PRODUCT DESCRIPTION

GENERAL SPECIFICATIONS AND PRODUCT DESCRIPTION AIR CONDITIONING GENERAL SPECIFICATIONS AND PRODUCT DESCRIPTION Effective 1 February 2013 PRODUCT DESCRIPTION - ALL MODELS FAN Direct drive, high efficiency, low noise. All polymer with taper lock quick

More information

L04 L29 (5 40 HP) FIXED-SPEED ROTARY SCREW COMPRESSORS. L-Series

L04 L29 (5 40 HP) FIXED-SPEED ROTARY SCREW COMPRESSORS. L-Series L04 L29 (5 40 HP) FIXED-SPEED ROTARY SCREW COMPRESSORS L-Series Advanced Technology Inspired Simplicity A Better Approach Champion has a long history of manufacturing compressed air equipment. With our

More information

See Note. 100% of rated load

See Note. 100% of rated load Generator set data sheet 2000 kw Continuous Model: Frequency: Fuel type: Emissions NOx: LT water inlet temp: HT water outlet temp: C2000 N6C 60 Hz Low BTU 0.5 g/hp-h 50 C (122 F) 92 C (198 F) Measured

More information

Crompton Greaves Limited

Crompton Greaves Limited Commercial Motors By FHP Motors Division Smart solutions. Strong relationships. Crompton Greaves Limited Single Phase Motors Range Product Parameters/Features 1. Voltage a. 90V to 130V b. 190 to 240 V

More information