2750 SERIES MODELS FEATURES WOB-L. Standard models 2750CE CGHI50. Other models based on availability and minimum purchase.
|
|
- Natalie Newman
- 6 years ago
- Views:
Transcription
1 WOB-L 2750 SERIES MODELS models 2750CE CGHI50 Other models based on availability and minimum purchase. 2750CE CGHI CS CS TGHI BE BGHI75 275OBS75 275OVEF VHI75 275OVS75 FEATURES Two cylinder, in-line Oil-less, non-lube piston and cylinder Permanently lubricated bearings Stainless steel valves with Patented recessed inlet valve Head design allows easily replaced piston seal Lightweight die cast aluminum components Thin wall, hard-coated aluminum cylinder for maximum heat transfer Twin fans provide cooling air through and around motor and cylinders 115 Volt, UL recognized motor and thermal protector Balanced for smooth, low vibration operation Field service capability Intake filter Capacitor All wetted aluminum parts treated for corrosion protection from moisture CE approved /50 hz standard models. (Consult factory for non-standard & TUV approved models.) Consult factory for custom applications ISO 9001 CERTIFIED
2 bar PSI bar MAX. CONTINUOUS PRESSURE MAX. MAX. MAX. RESTART 2750CE Inches " hg -881 mbar 115/60/ CE Inches PSI 1.0 bar 15 PSI 1.0 bar /60/ CGHI Inches 4.3 / / / / / / / / / / / / / / / PSI 2.8 bar 4.3 / / / / / / / / / / / / /50/1-230/60/ / / / SERIES Pressure & 02
3 bar PSI bar MAX. CONTINUOUS PRESSURE MAX. MAX. MAX. RESTART 2750CGHI Inches 5.3 / / / / / / / / / PSI 1.4 bar 20 PSI 1.4 bar 5.3 / / / / / / / / / / / / /50/1-230/60/ / / / CS Inches 4.4 / / / / / / / / / / / / / / / PSI 2.8 bar 4.4 / / / / / / / / / / / / / / / / CS Inches 5.3 / / / / / / / / / / / PSI 1.4 bar 25 PSI 1.7 bar 5.3 / / / / / / / / / / / / / / / SERIES Pressure & 03
4 bar PSI bar MAX. CONTINUOUS PRESSURE MAX. MAX. MAX. RESTART 2750TGHI48 Pressure Only.480 Inches 200v/240v 1.86 / / / / / / / / / / / / / / / / / / PSI 11 bar 160 PSI 11 bar 40 C 104 F 10 C 50 F /50/1 2.5 / / / CE NO OPEN PORT (AS CAST) 8.50± COOLING AIR FLOW DIRECTIONS 2750CS NO OPEN PORT (AS CAST) 8.50± COOLING AIR FLOW DIRECTIONS EXHAUST PORT (PULL PLUG) ROTATION M N CAPACITOR LEADS LINE LEADS 4.50± X FEMALE PRE-INSULATED QUICK DISCONNECTS (.250 X.032 TAB) EXHAUST PORT (PULL PLUG) ROTATION M N CAPACITOR LEADS LINE LEADS 4.50± X FEMALE PRE-INSULATED QUICK DISCONNECTS (.250 X.032 TAB) INTAKE PORT (PULL PLUG) FOOT TAP: 4X 1/4-20 INTAKE PORT (PULL PLUG) 9.29 FOOT TAP: M SERIES Pressure & 04
5 MAX. MAX. RESTART 2750BE " hg -915 mbar 115/60/ BGHI75 220v/50Hz-230v/60Hz 6.4 / / / / / / / / / / / / " hg -915 mbar 220/240-50/ /1 1.7 / / / BS / / / / / / / / / / / / " hg -915 mbar 4.0 / / / / SERIES 05
6 MAX. MAX. RESTART 2750VEF75 110/115v 3.14 / / / / / / / / / / / / " hg -986 mbar 115/60/1-110/50/1 4.1 / / / VHI75 220v/50Hz-240v/50Hz 3.29 / / / / / / / / / / / / " hg -975 mbar /50/1 1.3 / / / VS / / / / / / / / / / / / " hg -986 mbar 3.3 / / / / NO OPEN PORT (AS CAST) EXHAUST PORT (PULL PLUG) ROTATION M INTAKE PORT (PULL PLUG) N CAPACITOR LEADS ± COOLING AIR FLOW DIRECTIONS LINE LEADS 4.50± X FEMALE PRE-INSULATED QUICK DISCONNECTS (.250 X.032 TAB) FOOT TAP: 4X 1/4-20 The information presented in this material is based on technical data and test results of nominal units. It is believed to be accurate and reliable and is offered as an aid to help in the selection of Thomas products. It is the responsibility of the user to determine the suitability of the product for his intended use and the user assumes all risk and liability whatsoever in connection therewith. Thomas Industries does not warrant, guarantee or assume any obligation or liability in connection with this information. NOTE: Models pictured are representative of the series and do not represent a specific model number. Consult factory for detailed physical description. Form No / Gardner Denver Thomas, Inc. All rights reserved SERIES 06 Thomas Products Division 1419 Illinois Ave Sheboygan, WI USA Phone: (920) Fax: (920)
2668CE CHI CHI CE CE CHI CHI VE VGHI44
WOB-L 2668/2688 SERIES MODELS models 2668CE22 2668CE44 2668CHI22 2668CHI44 2688CE22 2688CE44 2688CHI22 2688CHI44 2688VE44 2688VGHI44 Other models based on availability and minimum purchase. 2668CE32 2668CE40
More informationWOB-L. PISTON Pumps and Compressors. 607/668/669/688/689 Series MODELS:
WOB-L PISTON Pumps and Compressors 607/668/669/688/689 Series MODELS: Standard models available. 607CA22, 607CA32, 607CD22, 607CD32 668CE44, 668CGHI44 688CE44, 688CGHI44 669CE44, 669CHGI44 689CE44, 689CGHI44
More information1/12, 1/6, 1/4, 1/3, 1/2, 3/4 & 1.0 HP
Articulating Piston TAskair (TA) Series /, /6, /4, /3, /, 3/4 &.0 HP MODELS TA-0-DC (70046) TA-30-DC (7004) TA-40-DC (7005) TA-40-DC (70047) TA-50-DC (70058) TA-50E (70063) TA-50E (70064) TA-60E (70066)
More information2755 Series BASE MODELS FEATURES 2755BE75 (115/60/1) 2755BGHI75 (230/601/1 & /50/1) 2755CE60 (115/60/1) 2755CGHI60 (230/601/1 & /50/1)
FEATURES > > Monolithic head > > Epoxy coated wetted parts > > 17mm shaft & bearing compliment > > Oil-less operation > > Permanently lubricated bearings > > Stainless steel valves > > Die-cast aluminum
More informationStandard Product Catalog
Standard Product Catalog WOB-L Piston MODEL SERIES Air Compressors & Vacuum Pumps LPM @ PSI (PSI) LPM @ IN.HG. (IN.HG.) VOLTAGE TYPE* 0 5 10 20 40 60 80 100 CONTINUOUS INTERMITTENT RESTART 0 5 10 15 20
More information7010 Series FEATURES BASE MODEL TYPICAL APPLICATIONS. Diaphragm. > > Oil-less > > Low vibration > > Low sound level
71 Series FEATURES > > Oil-less > > Low vibration > > Low sound level BASE MODEL 71 DC 71 AC 71Z DC 71Z AC TYPICAL APPLICATIONS > > Medical devices > > Clinical analyzers > > Air collector > > Inhalators
More information8011 Series FEATURES BASE MODEL TYPICAL APPLICATIONS. Diaphragm
811 Series FEATURES > > > > Maintenance free > > Low sound level > > Low vibration > > High performance BASE MODEL 811 AC 811Z AC TYPICAL APPLICATIONS > > Autoclaves > > Analysers > > Vacuum ovens > >
More informationImproving Lives through Innovation TM. Global Catalog. Compressors, Vacuum Pumps & Liquid Pumps
Improving Lives through Innovation TM Global Catalog Compressors, Vacuum Pumps & Liquid Pumps Pumps and Compressor Solutions for OEMs Worldwide As a leader in providing fluidic solutions to Original Equipment
More information7006 Series FEATURES BASE MODEL TYPICAL APPLICATIONS. Diaphragm. > > Oil-less > > Low vibration > > Low sound level
76 Series FEATURES > > Oil-less > > Low vibration > > Low sound level TYPICAL APPLICATIONS BASE MODEL 76 DC 76 AC 76 BLDC 76Z DC 76Z AC 76Z BLDC > > Medical devices > > Clinical analyzers > > Air collector
More informationCOMPRESSORS, VACUUM & LIQUID PUMPS Global Solutions
COMPRESSORS, VACUUM & LIQUID PUMPS Global Solutions INTRODUCTION / TABLE OF CONTENTS Pump and Compressor Solutions for OEMs Worldwide As the leader in providing fluidic solutions to Original Equipment
More informationAP LP LW YP YP-DU Series
AP LP LW YP YP-DU Series FEATURES > > Oil-less > > Long life > > Low power consumption > > Worldwide service network > > Low sound level/vibration > > Protection class IP54 (AP/LP/LW-Series) > > CE approved
More information3003 Series FEATURES BASE MODEL TYPICAL APPLICATIONS. Diaphragm. >>Oil-less. >>Low vibration. >>Low sound level. >>Compact design >>Lightweight
33 Series FEATURES BASE MOEL >>Oil-less 33 C >>Low vibration 33 LC >>Low sound level 33 BLC >>Compact design >>Lightweight TYPICAL APPLICATIONS >>Patient monitoring >>Anaesthetic control >>Gas detection
More information5002F Series FEATURES BASE MODEL TYPICAL APPLICATIONS. Diaphragm
52F Series FEATURES > > Self priming > > Dry running > > Oil-less, non lubricated > > Suitable for continuous operation > > Chemical resistant pump materials for aggressive media BASE MODEL 52F 52F Twin
More informationSee Note. 100% of rated load. Mechanical efficiency ISO3046/1 2,4,7 35.2% 34.8% 34.1% Electrical efficiency ISO3046/1 2,4,6,7 33.7% 33.4% 32.
Generator set data sheet 1000 kw (1250 kva) Standby Model: C1000 N6 Frequency: 60 Hz Fuel type: Natural gas MI 50 + Emissions NOx: 1.0 g/hp-hr LT water inlet temp: 50 C (122 F) HT water outlet temp: 90
More informationSee Note. 100% of rated load
Generator set data sheet 1250 kw (1563 kva) Standby Model: C1250 N6 Frequency: 60 Hz Fuel type: Natural gas MI 69 + Emissions NOx: 1.0 g/hp-hr LT water inlet temp: 50 C (122 F) HT water outlet temp: 90
More informationE. Clark & Associates 10 Brent Drive Hudson, MA Tel. 978 / Fax 978 / Two Switch Output Hex Screw Adjustment
CLARK SOLUTIONS 400 Series, Pressure, Vacuum, Diff. Pressure & Temp. Switches 1,2 & 3 Switch output, Adjustable Ranges 30 Vac to 6000 PSI, -180 to 650 o F DESCRIPTION The 400 Series is a versatile family
More informationFCX TECHNICAL BOOKLET
FAN COIL FCX US FCX USPO This document is based on AERMEC s FCX US, USP, USPO Technical and Installa on Booklet but reflects only those sizes and configura ons currently offered by Phoenix Energy Supply.
More informationAUTO-PUMP 120 VAC AIR COMPRESSOR SYSTEM INSTRUCTION MANUAL. 170 Cherry Avenue West Sayville, NY
INSTRUCTION MANUAL AUTO-PUMP 120 VAC AIR COMPRESSOR SYSTEM MODEL #: #:091-9B-1 091-9B-1 INPUT :120 volt, 50/60 Hz, 1.8 AMPS OUTPUT: 100 PSI MAXIMUM File: 091-9B-1_revA1_GEN3 Rev: A1 Revised By:PSS/JRN
More informationSee Note. 100% of rated load
Generator set data sheet 1400 kw Continuous Model: C1400 N6C Frequency: 60 Hz Fuel type: Natural gas MI 75 + Emissions NOx: 1.0 g/hp-hr LT water inlet temp: 50 C (122 F) HT water outlet temp: 90 C (194
More informationSee Note. 100% of rated load
Generator set data sheet 1160 kw Continuous Model: Frequency: C1160 N5C 50 Hz Fuel type: Natural gas MI 78 + Emissions NOx: 500 mg/nm 3 LT water inlet temp: HT water outlet temp: 50 C (122 F) 95 C (203
More informationSee Note. 100% of rated load
Generator set data sheet 2000 kw Continuous Model: C2000 N6C Frequency: 60 Hz Fuel type: Natural gas MI 76 + Emissions NOx: 0.5 g/hp-h LT water inlet temp: 50 C (122 F) HT water outlet temp: 92 C (198
More informationSee Note. 100% of rated load
Generator set data sheet 2000 kw Continuous Model: Frequency: Fuel type: Emissions NOx: LT water inlet temp: HT water outlet temp: C2000 N6C 60 Hz Low BTU 0.5 g/hp-h 50 C (122 F) 92 C (198 F) Measured
More informationMB Series AC Centrifugal Blowers
MB Series AC Centrifugal Blowers Impeller Diameter 6.3 in. dia. ( 16 mm) SAFETY STD. AC INPUT Specifications c Materials Motor Case: Casing: Impeller: Aluminum Voltage Frequency Current Input Power Max.
More informationSpa Pumps / Viper - 56-Frame
Spa Pumps / Viper - 56-Frame Viper wet end designed specifically for 56-frame motors Two double shielded ball bearings with moisture resistant grease for quieter operation and longer life Two speed motors
More informationAC axial fans, AC diagonal fans
fans, C diagonal fans Technology ccessories EC-SYSTEMS ESM General information K series Q-motor EC axial EC axial fans series fans fans Ø 130 - Ø 250 14 C diagonal fans Ø 208 20 13 Contacts fans Ø 130
More informationSTANDARD PRODUCT CATALOGUE EUROPE
STANDARD PRODUCT CATALOGUE EUROPE Vacuum/Pressure & Liquid to 365 l/min Market driven engineering For pumps and compressors, Thomas is the right contact. We understand our customers requirements: quiet
More informationSTANDARD PRODUCT CATALOG
STANDARD PRODUCT CATALOG Pumps and Compressor Solutions for OEMs Worldwide As the longtime leader in pressure and vacuum products for the OEM market, Thomas draws on nearly 50 years of technological strength.
More informationJ 6 Se r i e s. Pressure and Vacuum switches. features
J 6 S er i es J 6 Se r i e s Pressure and Vacuum switches features Gasketed, Die Cast Aluminum Enclosure with Epoxy Coating SPDT Switch Output Adjustable Deadband Option Sealed, Isolated Metal Bellows
More informationPalmer Circular Chart Recorders
Palmer Circular Chart Recorders Pressure & Temperature Recorders Designed for indoor or outdoor use, our recorders provide long service life, even in harsh conditions. Internal Assemblies, Clocks and Parts
More informationAC centrifugal fan. forward-curved, single-intake with housing (flange)
GE8-AA- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen Amtsgericht (court of
More informationDissolved Oxygen Measurement System with Air Blast Cleaner
Product Data Sheet PDS 71-DO-03/04/rev.D August 2004 MODEL DO -03/-04 Dissolved Oxygen Measurement System with Air Blast Cleaner COMPLETE SYSTEM INCLUDES sensor, analyzer, sensor washer head, mounting
More informationSee Note. 100% of rated load 2,4,6, (17.73)
Generator set data sheet 2000 kw Continuous Model: Frequency: C2000 N5CB 50 Hz Fuel type: Natural gas MI 70 + Emissions NOx: 350 mg/nm 3 LT water inlet temp: HT water outlet temp: 40 C (104 F) 92 C (198
More informationPrecision TIG 375. The Power To Perform! Advantage Lincoln TIG WELDERS. Output. Input 1 PHASE. Publication E /05
TIG WELDERS Precision TIG 375 The Power To Perform! The Precision TIG TM 375 delivers the Power to Perform setting a new standard in Square Wave Technology. Combining outstanding value-added features and
More informationProduct Data. FS3QX Slim Line Ducted Fan Coil With Plenum Sizes 018 thru 060 SLIM LINE DUCTED FAN COIL WITH PLENUM ON/OFF DISPLAY TEMP
FS3QX Slim Line Ducted Fan Coil With Plenum Sizes 018 thru 060 Product Data A114 SLIM LINE DUCTED FAN COIL WITH PLENUM Installation Ease S Factory installed 24 volt transformer and relay S High and low
More informationHIGH PRESSURE AIR COMPRESSOR SYSTEM MODEL #: 091-9HP-220 INPUT:
INSTRUCTION MANUAL AUTO-PUMP HP 240 VAC HIGH PRESSURE AIR COMPRESSOR SYSTEM MODEL #: 091-9HP-220 INPUT: 220-240 Vac, 50 Hz, 1.3 Amps 230 Vac, 60 Hz, 1.2 Amps File: IM_091-9HP-220-RevB2.indd Rev: B2 Revised
More informationTechnical Sales Guide # 040 YDFC 0 1 Page 2
17-18 Technical Sales Guide # 040 YDFC 0 1 Page 2 Technical Sales Guide # 040 YDFC 0 1 Page 3 York China Fan Coil Unit Model Type ST - Standard DC - District Cooling Number of rows 3: 3 Rows 4: 4 Rows
More information12-VOLT PUMPS CHOOSING A GPI ELECTRIC GEAR PUMP
12-VOLT S CHOOSING A GPI ELECTRIC GEAR When it comes to choosing an Electric Pump, GPI makes it easy! At Great Plains Industries, we recognize the differences in the needs of our customers. EZ-8 137100-01
More informationHBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR
PRODUCT SPECIFICATIONS *HBC(X) *PHBC(X) *RHBC(X) *CHBC(X) Chilled Water/Hot Water 2-pipe/4-Pipe HBC SERIES- HBCX SERIES-ECM MOTOR Ceiling Concealed Horizontal -1 CFM Ceiling Concealed Ceiling Recessed
More informationINSTRUCTION MANUAL FOR LINEAR COMPRESSORS
CONTENTS INSTRUCTION MANUAL FOR LINEAR COMPRESSORS MODEL EL-60 EL-10W EL-80-15 EL-150 EL-80-17 EL-00 EL-100 1. Parts name. Instructions -1 Prior to operation 3 - Storage and transfer 3-3 Installation 4
More informationINSTRUCTION MANUAL AUTO-PUMP 220/240 VAC MODEL #091-9B-220. INPUT :220/240 volt, 50/60 Hz, 1.9/2.2 AMPS OUTPUT: 100 PSI MAXIMUM 1 YEAR WARRANTY
BOOK# 091-9B-220 4-18-2002 INSTRUCTION MANUAL AUTO-PUMP 220/240 VAC AIR COMPRESSOR SYSTEM MODEL #091-9B-220 INPUT :220/240 volt, 50/60 Hz, 1.9/2.2 AMPS OUTPUT: 100 PSI MAXIMUM 1 YEAR WARRANTY KUSSMAUL
More informationSECTION MOTOR REQUIREMENTS for HVAC
PART 1 GENERAL 1.1 SECTION INCLUDES A. Single-phase electric motors B. Three-phase electric motors 1.2 REFERENCES SECTION 23 05 13 MOTOR REQUIREMENTS for HVAC A. ABMA 9 - Load Ratings and Fatigue Life
More informationLEGENDARY PRODUCTS & CUSTOMER SERVICE PUMPS & METERS FULL LINE OF QUALITY PRODUCTS MADE IN THE USA. Look for the red label! DOING BUSINESS SINCE 1972
LEGENDARY PRODUCTS & CUSTOMER SERVICE PUMPS & METERS MADE IN THE USA FULL LINE OF QUALITY PRODUCTS Look for the red label! DOING BUSINESS SINCE 1972 Great Plains Industries is a leading manufacturer of
More informationMax. oil content of compressed air
1 Version Control Certificates Ambient temperature min./max. Medium temperature min./max. Medium Poppet valve Analog CE declaration of conformity +32 F / +15 F +32 F / +15 F Compressed air 0012533 Max.
More informationBGD258 Series BASOTROL CE Approved Class A Gas Valve
Product Bulletin Issue Date May 21, 2010 BGD258 Series BASOTROL CE Approved Class A Gas Valve The BGD258 Series multi-function gas control valve works in conjunction with an electronic sequence control
More informationDEADMAN AND WATER CONTROL SYSTEMS
DEADMAN AND WATER CONTROLS _ BULLETIN 67 (07/05) DEADMAN AND WATER CONTROL SYSTEMS DEADMAN HANDLE AND CORD DEADMAN CONTROL SYSTEM WATER CONTROL SYSTEM COMBINATION DEADMAN AND WATER CONTROL SYSTEM * * *
More informationM-100 Adjustable flow switch with right-angle flow
M-100 Adjustable flow switch with right-angle flow Operating Instructions and Quick Start Guide Table of Contents Introduction 03 Operation 03 Storage and Handling 03 Installation Instruction 03 Specification
More information3-Phase Military AC-DC Power Supply 3-Phase, VrmsL-L
-4-1U 3-Phase Military AC-DC Power Supply 3-Phase, 8-265 VrmsL-L 47-8 Hz Semi-Regulated 28 V-48 V 4 W 525 W Transient Input Power Input Frequency Output Voltages Output Power Sealed Construction, Ultra
More informationB&M Super Cooler Mounting Guidelines
B&M Super Cooler Mounting Guidelines When considering installing a supplemental transmission fluid cooler B&M recommends the following guidelines for a successful and efficient installation: Mounting Recommendations
More information5 15 HP QUIET ENCLOSED RECIPROCATING AIR COMPRESSORS. Paradigm
5 15 HP QUIET ENCLOSED RECIPROCATING AIR COMPRESSORS Paradigm GARDNER DENVER PARADIGM Engineered Excellence Ultimate Performance A Winning Combination Gardner Denver compressors are proven units, known
More informationCC3060 TYPE 12 COMPACT CABINET COOLER AIR-TO-WATER FLUSH-MOUNT MODEL
CC3060 TYPE 12 CC3060 13 lbs 9,300 0.3 1 x 6 30 x 8-3/4 x 4 Efficiency: 68.8 Watts / C T based on average internal cabinet temperature. 2. CC3060 Rated cooling: 2,725 Watts mounted to an uninsulated 72
More informationMACHINES / RECLAIMS WITH DUST BAG
WARNING SET-UP INSTRUCTIONS MACHINES / RECLAIMS WITH DUST BAG *** READ BEFORE OPERATING EQUIPMENT *** 1. Remove plastic from machine. 2. Remove lag bolts from each of the four legs, then remove machine
More information12CS Series. Coreless Spin-on Filter Max. 75 l/min - 35 bar. Environmentally friendly alternative for spin-on filtration.
Coreless Spin-on Filter Max. 75 l/min - 35 bar Environmentally friendly alternative for spin-on filtration Lightweight, non-metallic element that can be incinerated The features a Parker, replaceable coreless
More informationGenerator set data sheet 1000 kw continuous. Fuel type: Natural gas MI 62 +
Generator set data sheet 1000 kw continuous Model: C1000 N6C Frequency: 60 Hz Fuel type: Natural gas MI 62 + Emissions NOx: 1.0 g/hp-h LT water inlet temp: 40 C (104 F) HT water outlet temp: 90 C (194
More informationUS U. Speed Control Motors. Features. Safety Standards and CE Marking M o t o r. Product Number Code
Speed Control Motors US Series The US series combines a speed control motor and a control unit. The capacitor and the potentiometer have been integrated into one compact control unit. The series is designed
More informationTM20UCM MODEL. Standard Features. Generator Ratings. Conditions of sale. Prime Hz 18 kw / 18 kva. General features :
TM20UCM MODEL Standard Features DIESEL GENSET TM20UCM Stand-by Power @ 60Hz 20kW / 20 kva Prime Power @ Hz 18 kw / 18 kva General features : Engine (MITSUBISHI, S4Q2.Y262SD ) Engine EPA Carb Charge alternator
More informationDIESEL GENSET. Prime 60Hz 91 kw / 114 kva
J100U MODEL DIESEL GENSET J100U Stand-by Power @ 60Hz 100kW / 125 kva Prime Power @ 60Hz 91 kw / 114 kva Standard Features General features : Engine (JOHN DEERE, 4045HF120 ) Charge alternator 12 V, Governor:Meca
More informationFR Heat Exchanger Unit Heater
Unit Heater Ruffneck are extra heavy duty (including heavy gauge steel construction) to meet the most demanding service and long life requirements for rugged industrial applications. The Series heaters
More informationPump Specifications 405 Series Commercial Drain Pump (High-Temp)
Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 405_P1 R8/22/2017 Copyright 2017 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice. 405-Series Dimensional
More informationBGD278 Series BASOTROL CE Approved Gas Valve
Product Bulletin Issue Date November 16, 2012 BGD278 Series BASOTROL CE Approved Gas Valve The BGD278 Series gas valve is a combination main and pilot valve intended for use in conjunction with solid-state
More informationVGD Series VGDxx.xxxU Gas Valves for use with SKPxx.xxxU electro hydraulic actuators
VGD Series VGDxx.xxxU Gas Valves for use with SKPxx.xxxU electro hydraulic actuators Technical Instructions Document No. 7631 VGDxx.xxxU VGD20.xxxU VGD40.xxxU ISO 9001 and 14000 REGISTERED FIRM Only with
More informationAC centrifugal module - RadiCal
KE5-RA- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen Amtsgericht (court of
More informationDIESEL GENSET. Prime 60Hz 36 kw / 45 kva
J40UC MODEL DIESEL GENSET J40UC Stand-by Power @ 60Hz 40kW / 50 kva Prime Power @ 60Hz 36 kw / 45 kva Standard Features General features : Engine (JOHN DEERE, 3029TF270 ) Engine EPA Carb Charge alternator
More informationPrime Hz 400 kw / 500 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva
GS500K MODEL DIESEL GENSET GS500K Stand-by Power @ 50Hz 440kW / 550 kva Prime Power @ Hz 400 kw / 500 kva Standard Features General features : Engine (VOLVO, TAD1631GE ) Charge alternator 24 V, Governor:Electronic
More informationPrime 60Hz 455 kw / 568 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva
V500UC MODEL DIESEL GENSET V500UC Stand-by Power @ 60Hz 500kW / 625 kva Prime Power @ 60Hz 455 kw / 568 kva Standard Features General features : Engine (VOLVO, TAD1641GE ) Engine EPA Carb Charge alternator
More informationPrime 60Hz 18 kw / 18 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings Prime Ratings kw/kva 240MONO / / 18
T20UCM MODEL DIESEL GENSET T20UCM Stand-by Power @ 60Hz 20kW / 20 kva Prime Power @ 60Hz 18 kw / 18 kva Standard Features General features : Engine (MITSUBISHI, S4Q2.Y262SD ) Engine EPA Carb Charge alternator
More informationDIESEL GENSET. Prime 60Hz 55 kw / 68 kva
J60UC MODEL DIESEL GENSET J60UC Stand-by Power @ 60Hz 60kW / 75 kva Prime Power @ 60Hz 55 kw / 68 kva Standard Features General features : Engine (JOHN DEERE, 4045TF270 ) Engine EPA Carb Charge alternator
More informationINDUSTRIAL TAPE PRODUCT GUIDE
INDUSTRIAL TAPE PRODUCT GUIDE POLYESTER FILM TAPES Ideal Tape s complete line of pressure-sensitive polyester film tapes are backed by more than 100 years of coating experience. These products are widely
More informationSECTION METERS AND GAUGES FOR HVAC PIPING
SECTION 23 05 19 METERS AND GAUGES FOR HVAC PIPING PART 1 - GENERAL 1.1 SUMMARY A. Work included: Provision of materials, installation and testing of: 1. Thermometers 2. Thermometer Wells 3. Differential
More informationDIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings 1 kw/kva
R33 MODEL Stand-by Power @ 50Hz Prime Power @ 50Hz DIESEL GENSET R33 26kW / 33 kva 24 kw / 30 kva Standard Features General features : Engine (JOHN DEERE, 3029DF120) Radiator 50 C [122 F] C max. T air
More informationVAL-AIR AIR COMPRESSORS
VAL-AIR AIR COMPRESSORS All Val-Air Compressors are virtually soundless and are totally automatic. Each unit includes a tank pressure gauge, line pressure gauge, line pressure regulator, moisture trap/filter,
More information4-in-1 MOTORS ONE SIMPLE CONNECTION
4-in-1 MOTORS 4-IN-1 MULTI-HORSEPOWER MOTORS Class B Insulation 60 C (140 F) Max Ambient FEATURES UL/CSA approved Class B insulation All-angle mount Energy-efficient PSC design Lead length 36 to 48 Reversing
More informationPOWER ACCESSORIES SOCKET ASSEMBLIES CIGARETTE LIGHTER PLUGS BATTERY DISCHARGE PROTECTOR VOLTAGE REDUCERS VOLTAGE CONVERTER VOLTAGE BOOSTER INVERTERS
SOCKET ASSEMBLIES CIGARETTE LIGHTER PLUGS BATTERY DISCHARGE PROTECTOR VOLTAGE REDUCERS VOLTAGE CONVERTER VOLTAGE BOOSTER INVERTERS SOCKET ASSEMBLIES 853010BL Blister Pack Surface Mount Aluminum Accessory
More informationPrime 60Hz 273 kw / 341 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva
V300UC MODEL DIESEL GENSET V300UC Stand-by Power @ 60Hz 300kW / 375 kva Prime Power @ 60Hz 273 kw / 341 kva Standard Features General features : Engine (VOLVO, TAD941GE ) Engine EPA Carb Charge alternator
More informationSECTION COMMON MOTOR REQUIREMENTS FOR HVAC EQUIPMENT
SECTION 230513 - COMMON MOTOR REQUIREMENTS FOR HVAC EQUIPMENT PART 1 GENERAL 1.1 SECTION INCLUDES A. Single phase electric motors. B. Three phase electric motors. 1.2 REFERENCE STANDARDS A. ABMA STD 9
More informationQUINCY QRD SERIES SINGLE-STAGE, 2-20 HP TWO-STAGE, 5-30 HP OIL-LESS RECIPROCATING COMPRESSORS
QUINCY QRD SERIES SINGLE-STAGE, 2-20 HP TWO-STAGE, 5-30 HP OIL-LESS RECIPROCATING COMPRESSORS OIL-LESS COMPRESSORS QUINCY QRDS, SINGLE-STAGE Clean, oil-less air Quincy dependability High-efficiency, clean
More informationMODEL 7ASX-8 SPECIFICATION
MODEL 7ASX-8 SPECIFICATION 1.0 General Specifications There shall be furnished one (1) one only Grind Hog TM Model 7ASX-8 HEAVY DUTY Comminutor as manufactured by G.E.T. Industries Inc. with rotation in
More informationCT-901HP. HYDRAULIC COMPRESSION SYSTEM OPERATION and MAINTENANCE INSTRUCTIONS
Panduit Corp. 2013 HYDRAULIC COMPRESSION SYSTEM OPERATION and MAINTENANCE INSTRUCTIONS PA25404A01 Rev. 01 5-2013 PRECAUTIONS... 1 INTRODUCTION... 1 SYSTEM SPECIFICATIONS... 2 OPTIONAL ACCESSORIES... 2
More information10 S e r i e s PRESSURE SWITCH. features
10 S er i es 10 S e r i e s PRESSURE SWITCH features Tamper-Resistant Field Adjustment Adjustable Ranges from 4 to 7500 PSI (0,3 to 517,1 Bar) Choice of 7 Electrical Terminations 1-1/4" Diameter Height
More informationENGINE DATA. 205L/s [434cfm] 565 C [1049 F] 750mm CE [30in. WG
R90K DIESEL GENSET MODEL R90K Stand-by Power @ Hz Prime Power @ Hz 70 kw / 88 kva 64 kw / 80 kva Standard Features General features : Engine (JOHN DEERE, 4045TF220) Radiator C [122 F] C max. T air inlet
More informationDIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings 1 kw/kva
R110K MODEL Stand-by Power @ 50Hz Prime Power @ 50Hz DIESEL GENSET R110K 88 kw / 110 kva 80 kw / 100 kva Standard Features General features : Engine (JOHN DEERE, 4045HF120) Radiator 50 C [122 F] C max.
More informationNEW! BOOSTER PUMPS. HBP/HBPS series 4" horizontal booster pumps. booster pumps
HBP/HBPS series 4" horizontal The HBP/HBPS Series Booster Pumps are the most durable available. The patented SignaSeal floating impeller design minimizes thrust loads, allowing for continuous operation
More informationEngine Performance 1500 RPM
CUMMINS ENGINE COMPANY, INC Columbus, Indiana 471 ENGINE PERFORMANCE CURVE Basic Engine Model: QST-G3 Engine Critical Parts List: CPL: 284 Curve Number: FR-188 Date: 23Dec3 Q 1 Displacement :.48 liter
More informationG100U MODEL STANDARD FEATURES GENERATOR RATINGS CONDITIONS OF SALE. General features :
G100U MODEL Stand-by Power @ 60Hz Prime Power @ 60Hz G100U 80-100 kw /80-5 kva 71-94 kw / 71-118 kva GAS GENSET STANDARD FEATURES General features : SDMO Industries provides one-source responsibility for
More information2 30 HP RECIPROCATING AIR COMPRESSORS. R-Series
2 30 HP RECIPROCATING AIR COMPRESSORS R-Series CHAMPION R-SERIES Customized Solutions Unparalleled Performance A Winning Combination Champion compressors are proven units, known for their reliability over
More informationMcGUIRE AIR COMPRESSORS HP RECIPROCATING AIR COMPRESSORS. R-Series. McGUIRE AIR COMPRESSORS
2 30 RECIPROCATING AIR COMPRESSORS R-Series CHAMPION R-SERIES Customized Solutions Unparalleled Performance A Winning Combination Champion compressors are proven units, known for their reliability over
More information12CS/50CS Series Coreless Medium Pressure Filters
12CS/5CS Series Coreless Medium Pressure Filters 65 12CS/5CS Series Applications Together we can Preserve the environment. Minimize waste and promote energy efficiency. Achieve worldwide filtration solutions.
More informationSEM SERIES FEATURES SEM 7820 MAGNET SEM FEATURES
SEM 7820 MAGNET Die Cast, Floor mounted. SEM 7820 Total Projection = 6-3/4 (171 mm) SEM SERIES The Sentronic SEM 7800 Series are heavy duty, electrically controlled door holding magnets. Magnets are fail
More informationDIESEL GENSET. Prime Hz 16 kw / 20 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva
TM20K MODEL DIESEL GENSET TM20K Stand-by Power @ 50Hz 18kW / 22 kva Prime Power @ Hz 16 kw / 20 kva Standard Features General features : Engine (MITSUBISHI, S4Q2.SD ) Charge alternator 12 V, Governor:Meca/Mechanical
More informationPUMPS SURFACE C ATA L OGU E SURFACE PUMPS
SURFACE C ATA L OGU E PUMPS SURFACE PUMPS www.vansan.co.za IDB Series Peripheral Pumps 8 ISO2548-C 22V/5HZ 6 4 2 5 1 2 25 35 4 45 l/min IDB4 IDB35 IDB6 IDB7.3.6.9 1.2 1.5 1.8 2.1 2.4 2.7 m 3 /h Ampere
More informationFADE SERIES. Typical Specifications for Model FADE Sidewall Propeller Fans Sidewall propeller fans shall be of the direct driven type.
January 2008 FADE0108 Fantech, Inc. certifies that the FADE Series shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA
More informationDIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva
J33 Standard Features MODEL Stand-by Power @ 50Hz Prime Power @ 50Hz DIESEL GENSET J33 26kW / 33 kva 24 kw / 30 kva General features : Engine (JOHN DEERE, 3029DF120 ) Charge alternator 12 V, Governor:Meca
More informationVertical Floor Fan Coil Unit (Model FW)
Technical Bulletin Issue Date March 24, 2005 Vertical Floor Fan Coil Unit (Model FW) Figure 1: Model FWX Vertical Exposed Model FW Vertical Floor fan coil units are designed to maximize flexibility of
More informationFull Load Amps Model Number List 1.52/ / / / / /1.3 4/2 3.6/1.8 4/2 4.4/ / / /2.8 2.
Variable Speed & : VAC, Hz Input Ratings (V/Hz Mode) & Enclosures (V/Hz Mode) Enclosures (Frames 2-445T) (V/Hz Mode) Enclosures (Frames 447-449T) Variable (V/Hz Mode) & Enclosures PowerMatch With All Reliance
More informationMODEL TD-MIXVENT INLINE MIXED FLOW DUCT FAN
MODEL FEATURES Exhaust air up to 2,630 CFM with static pressure capabilities to 1 w.g. Mixed flow impeller for excellent air flow to pressure performance ratio Direct connection, two-speed motor Ideal
More informationDD25B. Volvo Double Drum Compactors 2.6 t 18.5 kw
DD25B Volvo Double Drum Compactors 2.6 t 18.5 kw 360 visibility With an optimally positioned sliding seat, angled drum mounts and a sloping hood design, the DD25B provides industry-leading, all-around
More informationAC centrifugal fan. forward-curved, dual-intake with housing (without flange)
DE-AM7-65 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen Amtsgericht (court of
More informationDIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva
J440K Standard Features MODEL Stand-by Power @ 50Hz Prime Power @ 50Hz DIESEL GENSET J440K 352kW / 440 kva 320 kw / 400 kva General features : Engine (JOHN DEERE, 6125HF070-387 ) Charge alternator 24 V,
More informationP66 Series Electronic Fan Speed Controls
FANs 125, 121 Pressure Controls Section P Product/Technical Bulletin P66 Issue Date 0498 P66 Series Electronic Fan Speed Controls The P66 is a pressure actuated electronic motor speed controller. This
More informationModel 8144NC Fresh Air Ventilator
Model 8144NC Fresh Air Ventilator Installation and Operating Instructions MOUNTING BRACKETS WIRE ENTRY LOCATION INTEGRAL PRESSURE PORTS (PORT ON INLET SIDE NOT SHOWN) OVAL OUTLET COLLAR FOR 6" DIAMETER
More informationVoltage HZ Phase P.F Standby Amps Standby Ratings kw/kva. Prime Ratings kw/kva 240MONO / 10 9 / 9
TM11UCM MODEL Stand-by Power @ 60Hz Prime Power @ 60Hz DIESEL GENSET TM11UCM 10kW / 10 kva 9 kw / 9 kva Standard Features General features : Engine (MITSUBISHI, S3L2.W262SD ) Engine EPA Carb Charge alternator
More information