OTHER PRODUCTS FROM THE TURNBULL & SCOTT RANGE

Size: px
Start display at page:

Download "OTHER PRODUCTS FROM THE TURNBULL & SCOTT RANGE"

Transcription

1 OTHER PRODUCTS FROM THE TURNBULL & SCOTT RANGE THERMOLIER UNIT HEATERS TRENCH HEATING DADO HEATING RAIL HEAT EXCHANGERS GILLED TUBING RADIANT STRIP BLAST COOLERS RADIANT PANELS SKIRTING HEATING BOILER HOUSES Certificate No. 698/95 T: +44 (0) F: +44 (0) E: HEAD OFFICE Commercial Road, Hawick, Roxburghshire, Scotland TD9 7AQ Due to continuous improvement, we reserve the right to change the specifications within this brochure without notice.

2 WHEN ALL YOUR HEAT RISES INTO A BIG EMPTY SPACE DON T LET IT STAY THERE. INTRODUCING THERMOLIER FAN HEATERS FROM TURNBULL & SCOTT CONTENTS FEATURES & BENEFITS P4-5 PERFORMANCE & DIMENSIONS P6-7 HEAT OUTPUT CHARTS P8-10 TECHNICAL SUPPORT P11 3

3 MAKING HOT AIR EFFICIENT THERMOLIER UNIT HEATERS are part of a fan driven hot air heating system which utilises heat exchange technology to keep cost at bay. Units are available in horizontal and downflow (vertical) models for use with steam or hot water. Front louvers and careful situation of the units gives exceptionally fast warm up and practical heat control in large spaces. Requiring little or no maintenance, this system is tough and efficient. High ceiling locations almost inevitably need Thermolier as part of an effective heating solution. Easy to install and control, features include improved air circulation, moisture resistance and no need for wall space. Ducting can also be connected to the rear of the unit to draw fresh air from outside the building or to the front for distribution through a ceiling void or partition to the working area. WHY QUALITY COSTS LESS FAN GUARD & ACCESS Fan guard need not be removed to wire up motor as with more common units. Quick and inexpensive wiring of motor CASING Maximum corrosion resistance & minimum maintenance by use of zintec steel - stove enamelled. Last longer. Maintains neat appearance BENEFITS Three year guarantee Installation and design service ensures correct selection Thick wall copper tubes which provide longer life Superior tube to fin bond ensures high performance Ferruled tube to header joint uses thermal expansion to ensure a tight joint Boiler plate header channels eliminate warping or damage when piping up Variety of gill spacing allows greater selection of leaving air temperatures Deep blade propeller type fan dynamically balanced quiet and efficient operation Totally enclosed B.S motors used with sealed for life ball bearings require no maintenance Two coat stove enamelled zintec casing resists corrosion The fan guard is fingerproof and does not need to be removed to make electrical connections to the motor MOTOR Enclosed fractional horsepower motor with sealed for life ball-bearings. No lubrication required. Generously rated. Maintenance free long-life TUBE JOINT Unique joint that strengthens with temperature and pressure. Greater strength joint creates more robust radiator FEATURES Provides high output and quick pre-heating Low installation costs Simple zone control Neat unobtrusive appearance Compact design Over 500 variants available Motors are available in a range of speeds Flameproof motors are available ex-stock Diffusers are available or downflow models with one, two or four way louvres TUBE Special wall thickness 15mm high grade copper. Increased heat transfer obtained by mechanically bonding tubes to fins with expansion bullet thus eliminating air gap between tube and fin. Longer life. More efficient heat transfer LOUVRES Individually adjustable louvres in any combination of one, two, three or four way discharge. Any air distribution pattern can be obtained 4 DESIGNED TO USE FOR ANY COMMERCIAL OR INDUSTRIAL ENVIRONMENT INCLUDING: FACTORIES WAREHOUSES DRYING ROOMS SWIMMING POOLS LOADING DOORS 5

4 GENERAL PERFORMANCE AND DIMENSIONS GENERAL PERFORMANCE AND DIMENSIONS 6 DIMENSIONS DIM. A B C D Connection Weight Size mm in mm in mm in mm in mm in kg lb / / / / / / / / / / / / / / / / / / HYDRAULIC RESISTANCE - Kpa FLOW LITRES/SEC MEAN WATER SIZE TEMP C Row Row Row Row Row Row Row Row Row Row SPECIFICATION Casing is constructed from 1mm thick zinc coated steel to BS The body and louvers are stove enamel finished in post office red with the louvre box and fan guard black. Overall Thermolier dimensions/weight and inlet connections vary, dependent upon customer requirements. However, please feel free to contact us for product selection assistance on +44 (0) Heater battery is constructed using 15mm outside diameter specifically made thick walled copper tubes to BS.2870 grade C106. The gills are 0.35mm thick aluminium to B.S The boiler plate header channels are 8mm thick steel to BS B. Eyebolts are secured to lugs welded directly to the headers. The battery is hydraulically tested to 25 bar for not less than five minutes. Motor and fan assembly is a continuously rated, totally enclosed air over motor type with 1P44 protection against the penetration of dust and moisture into the windings. The motor fully complies with BS.2048 pt. 1, BS 5000 pt. 2 and BS DESIGN & INSTALLATION The Thermolier Design Team will design a Thermolier Installation to suit customers individual requirements. Turnbull & Scott also offer a full installation package including boiler house design if required. THREE YEAR GUARANTEE A Thermolier Unit Heater found to be defective due to workmanship or materials within three years of it s despatch from our works will be repaired or replaced, at our discretion, if returned to our works. QUALITY ASSURANCE Over 50 years experience ensures that all components are manufactured to appropriate British Standards and quality procedures BS.EN.ISO 9001/:2000. HORIZONTAL UNIT *Overall length of unit when fitted with front angle flange. DOWNFLOW UNIT Certificate No. 698/95 The information contained in this data sheet has been formulated to assist the customer in the selection of the heating units most suited to their requirements. SUMMARY OF MODEL REFERENCE Model reference is shown with an explanation of each digit. Example: 326N-S-H-3 RPM Is the motor revolutions per minute. MOUNTING HEIGHT The mounting height should be selected with due regard to leaving air temperature. 3 2 COVERAGE In the case of horizontal units this indicates the effective throw. In the case of a downflow unit it represents the diameter of area covered. 6 N S H 1-5 Physical Size (Five standard sizes) 2-3 Number of tube rows (2 or 3 depending on heating type) 3-6 Number of mm between gills (3 or 6mm to suit Leaving Air Temperature) L Low speed motor N Normal speed motor S Steam type W Water type TH.F Thermal fluid type D Downflow H Horizontal D2 Two way downflow MOUNTING HEIGHTS HORIZONTAL MODEL REFERENCE RPM DOWNFLOW COVERAGE VOLUME VELOCITY M M M M3/SEC M/S 126L N L N L N L N L N L N L N L N L N L N L N L N L N L N L N VOLUME The volume of air entering the unit. VELOCITY The speed of air leaving the unit at 50 O C when entering air temperature is 16 O C. 7

5 8 STEAM THERMAL OUTPUTS ENTERING AIR TEMPERATURE 20 O C (NORMAL ROOM TEMPERATURE) STEAM PRESSURE 1 BAR 2 BAR 3 BAR 4 BAR 6 BAR 8 BAR MODEL KW L A T C KW L A T C KW L A T C KW L A T C KW L A T C KW L A T C 126L-S N-S L-S N-S L-S N-S L-S N-S L-S N-S L-S N-S N-S N-S N-S N-S ENTERING AIR TEMPERATURE 10 O C (FROST PROTECTION) 126L-S N-S L-S N-S L-S N-S L-S N-S L-S N-S L-S N-S N-S N-S N-S N-S ENTERING AIR TEMPERATURE -1 O C (FRESH AIR INTAKE START-UP) 126L-S N-S L-S N-S L-S N-S L-S N-S L-S N-S L-S N-S N-S N-S N-S N-S FORMULA TO OBTAIN STEAM CONSUMPTION WATTS 580 =Kg/Hr L.P.H.W THERMAL OUTPUTS ENTERING AIR TEMPERATURE 20 O C (NORMAL ROOM TEMPERATURE) WATER TEMP. 65 C 70 C 75 C 80 C 85 C 90 C TEMPERATURE DROP 10 C 10 C 10 C 10 C 10 C 10 C MODEL KW L A T C KW L A T C KW L A T C KW L A T C KW L A T C KW L A T C 123L-W N-W L-W N-W L-W N-W L-W N-W L-W N-W L-W N-W N-W N-W N-W N-W ENTERING AIR TEMPERATURE 10 O C (FROST PROTECTION) 123L-W N-W L-W N-W L-W N-W L-W N-W L-W N-W L-W N-W N-W N-W N-W N-W ENTERING AIR TEMPERATURE -1 O C (FRESH AIR INTAKE START-UP) 123L-W N-W L-W N-W L-W N-W L-W N-W L-W N-W L-W N-W N-W N-W N-W N-W KW FORMULA TO OBTAIN WATER FLOW RATE TEMPERATURE DROP X 4.18 = Litres/Sec 9

6 H.P.H.W THERMAL OUTPUTS ENTERING AIR TEMPERATURE 20 O C (NORMAL ROOM TEMPERATURE) TECHNICAL SUPPORT THAT NEVER FALTERS. 10 MEAN WATER TEMP. TEMPERATURE 130 C 140 C 150 C DROP 20 C 30 C 30 C 40 C 30 C 40 C MODEL KW L A T C KW L A T C KW L A T C KW L A T C KW L A T C KW L A T C 126L-W N-W L-W N-W L-W N-W L-W N-W L-W N-W L-W N-W N-W N-W N-W N-W ENTERING AIR TEMPERATURE 10 O C (FROST PROTECTION) 126L-W N-W L-W N-W L-W N-W L-W N-W L-W N-W L-W N-W N-W N-W N-W N-W ENTERING AIR TEMPERATURE -1 O C (FRESH AIR INTAKE START-UP) 126L-W N-W L-W N-W L-W N-W L-W N-W L-W N-W L-W N-W N-W N-W N-W N-W FORMULA TO OBTAIN WATER FLOW RATE KW TEMPERATURE DROP X 4.18 = Litres/Sec Our technical support service has been specifically developed to meet the demands and expectations of specifier partners, architects, engineers, consultants and contractors. We understand that time is always at a premium and sound technical information is as essential as quality manufacture and attentive aftersales service. One of our core strengths is the knowledge base held within our technical design office. So important is this aspect of our business that General Manager, Jim Davidson, has direct responsibility for this facility. He heads up the contact team for your technical information, design, estimating, project management and production enquiries. Jim is supported in the field by Rodger Atkins, our technical support representative. Should you require any information or wish to view samples during the early stages of your project, please do not hesitate to call our technical team. SUPPORT SERVICES COMPLETE THE SOLUTION In addition to the manufacture and distribution of commercial space heating systems, we offer a range of installation and maintenance services to assure you of continued reliable performance for years to come. INSTALLATION Since the 50s, Turnbull & Scott expert installation teams have undertaken projects throughout the UK and Europe. As you might expect, intimate knowledge of our product range inevitably leads to efficient, cost effective, quality installation of your heating solution. This service is available for all Turnbull & Scott systems. MAINTENANCE, REPAIR AND REPLACEMENT While our products are renowned for their reliability, from time to time repair or replacement is necessary. In some instances, we repair and replace units that have given reliable service for over 40 years. Rather than a full replacement programme, a lower cost refurbishment exercise may be undertaken for further decades of efficient heating. Our installation teams also provide service cover throughout the UK. For any questions regarding our technical support services call us on +44 (0)

TECHNICAL DOCUMENTATION WOLF AIR HEATERS LH-EC / LH. 30m 3 /h

TECHNICAL DOCUMENTATION WOLF AIR HEATERS LH-EC / LH. 30m 3 /h TECHNICAL DOCUMENTATION WOLF AIR HEATERS LH-EC / LH 30m 3 /h THE EXTENSIVE EQUIPMENT RANGE from system supplier WOLF offers the ideal solution for commercial and industrial buildings, new build and modernisation

More information

AH / AV. Advanced Series Unit Heaters AH / AV. Ruffneck

AH / AV. Advanced Series Unit Heaters AH / AV. Ruffneck The Ruffneck Advanced Series heaters are designed for rugged industrial applications and are available in 37 models from 6,000 to 1,,000 Btu/hr With a maximum operating pressure and temperature rating

More information

Rosemex Products 2009 HEATING UNIT HEATERS FOR STEAM OR HOT WATER

Rosemex Products 2009 HEATING UNIT HEATERS FOR STEAM OR HOT WATER 01 Rosemex Products 09 HEATING UNIT HEATERS FOR STEAM OR HOT WATER 2 UNIT HEATERS FEATURES BROAD RANGE OF APPLICATION Hot water or steam ROSEMEX unit heaters provide economical space comfort for industrial,

More information

Unit Heaters. Catalog MANUFACTURERS HEATING PRODUCTS. Tel: (905) Fax: (905) OF HYDRONIC.

Unit Heaters. Catalog MANUFACTURERS HEATING PRODUCTS.   Tel: (905) Fax: (905) OF HYDRONIC. Catalog MANUFACTURERS OF HYDRONIC HEATING PRODUCTS Tel: (905) 670-3200 Fax: (905) 670-3822 General Product Overview Sigma horizontal and vertical propeller unit heaters feature a wide performance range

More information

fåçìëíêá~ä=~áê=åççäéêë=qvo pí~åç~êç=åççäéêë=ïáíü=ëí~áåäéëë=ëíééä=íìäáåö

fåçìëíêá~ä=~áê=åççäéêë=qvo pí~åç~êç=åççäéêë=ïáíü=ëí~áåäéëë=ëíééä=íìäáåö fåçìëíêá~ä=~áê=åççäéêë= pí~åç~êç=åççäéêë=ïáíü=ëí~áåäéëë=ëíééä=íìäáåö O `çåíéåíë= page Model indication..................................2 Eurovent.......................................2 Capacities......................................2

More information

SRH2. Steam Rig Heater. Industrial Grade Heat-Exchanger Unit Heaters. CRN: 0H C 150 psig (1034 KPa)

SRH2.   Steam Rig Heater. Industrial Grade Heat-Exchanger Unit Heaters. CRN: 0H C 150 psig (1034 KPa) SRH2 EAC Ex models available. Contact factory! Steam Rig Heater CRN: 0H14931.2C 150 psig (1034 KPa) Industrial Grade Heat-Exchanger Unit Heaters www.hazlocheaters.com is a manufacturer of industrial-grade

More information

NH 3. Evaporator. Ammonia Applications Tons MANP

NH 3. Evaporator. Ammonia Applications Tons MANP NH 3 Evaporator Ammonia Applications 12-108 Tons > > Used for medium TO large Industrial Ammonia applications Manufactured with Stainless steel tubes. The Global Leader In Heat Exchange Technology With

More information

Dual discharge air coolers THOR-D. Standard coolers in a revolutionary design

Dual discharge air coolers THOR-D. Standard coolers in a revolutionary design Dual discharge air coolers THOR-D Standard coolers in a revolutionary design O jççéä=áåçáå~íáçå `çåíéåíë= page Model indication................................ 2 Eurovent......................................

More information

INDEX. The technical and dimensional data reported in this manual may be modified in view of any product improvement.

INDEX. The technical and dimensional data reported in this manual may be modified in view of any product improvement. Ceiling-mounted fan heaters TECHNICAL MANUAL GB INDEX 1 MAIN FEATURES... 2 2 RATED TECHNICAL DATA... 3 3 HEATING CAPACITIES... 4 3.1 Heating capacity with water operation... - 11 4 STEAM OPERATION... 12

More information

Complete HVAC Capability

Complete HVAC Capability Air Handling Units Brochure 1110 January 2006 Complete HVAC Capability MEA Horizontal Draw-Thru to Size 65 Vertical Draw-Thru to Size 50 1000 to 60,000 CFM Forward Curved or Airfoil Wheels Inlet Vane Option

More information

Multi directional heating. Air heaters Model NOZ

Multi directional heating. Air heaters Model NOZ Multi directional heating Air heaters Model NOZ Air heaters The ideal heat source for large buildings Air heaters are used for the heating and ventilation of large industrial buildings. New industrial

More information

^áêëçåâ=ìåáí=åççäéêë=qvoj^ pí~åç~êç=åççäéêë=ïáíü=pí~áåäéëë=píééä=íìäáåö

^áêëçåâ=ìåáí=åççäéêë=qvoj^ pí~åç~êç=åççäéêë=ïáíü=pí~áåäéëë=píééä=íìäáåö ^áêëçåâ=ìåáí=åççäéêë= pí~åç~êç=åççäéêë=ïáíü=pí~áåäéëë=píééä=íìäáåö O `çåíéåíë= page Model indication................................ 2 Eurovent...................................... 2 Capacities.....................................

More information

PUNKAH LOUVRES - PKL DESCRIPTION & FEATURES

PUNKAH LOUVRES - PKL DESCRIPTION & FEATURES PUNKAH LOUVRES - DESCRIPTION & FEATURES Punkah Louvres are suitable for high velocity spot cooling applications. The unit is fully adjustable and can be used as either a jet or diffused air outlet. Fully

More information

Sabre Plate Mounted Sickle Fans (VSP)

Sabre Plate Mounted Sickle Fans (VSP) Sabre Plate Mounted Sickle Fans (VSP) Swept impeller with Aerofoil blades, winglets and serrated trailing edge for optimum performance One shot die cast impeller, dynamically balanced for smoother operation

More information

HP Heat Exchanger Unit Heater

HP Heat Exchanger Unit Heater Unit Heater Ruffneck are extra heavy duty (including heavy gauge steel construction) to meet the most demanding service and long life requirements for rugged industrial applications, such as space heating

More information

Airsock unit coolers THOR-A. Standard coolers in a revolutionary design

Airsock unit coolers THOR-A. Standard coolers in a revolutionary design Airsock unit coolers THOR-A Standard coolers in a revolutionary design O jççéä=áåçáå~íáçå `çåíéåíë= page Model indication................................ 2 Eurovent......................................

More information

Dual Discharge Evaporator (DX) Freon Applications 1-19 Tons MDN

Dual Discharge Evaporator (DX) Freon Applications 1-19 Tons MDN Dual Discharge Evaporator (DX) Freon Applications 1-19 Tons MDN > > Used for small to medium Freon applications The Global Leader In Heat Exchange Technology With seven decades of experience and commitment

More information

Modular Air Handling. Up to 3,500 Litres / sec. Low profile & Plant room application. Draft. Version. Second Edition A-. AirDesign 2015 AirDesign 2016

Modular Air Handling. Up to 3,500 Litres / sec. Low profile & Plant room application. Draft. Version. Second Edition A-. AirDesign 2015 AirDesign 2016 Modular Air Handling U n i t R a n g e Up to 3,500 Litres / sec Low profile & Plant room application AirDesign 2015 AirDesign 2016 Second Edition Draft Version A-. Air Design is a proud Australian based

More information

DATA & FACTS Unit Heaters MultiMAXX HB. Quick Selection and Fast Delivery

DATA & FACTS Unit Heaters MultiMAXX HB. Quick Selection and Fast Delivery DATA & FACTS Unit Heaters MultiMAXX HB Quick Selection and Fast Delivery Table of Contents MultiMAXX HB Unit Type Code... 3 About this Catalogue... 4 Overview of Capacity... 5 Unit Description... 6 Unit

More information

Features: Available in horizontal and vertical units

Features: Available in horizontal and vertical units Features: Available in horizontal and vertical units Ideal for Shopping Malls, Retail Outlets and Office Receptions Can be supplied in a large range of colours and finishes Numerous mounting bracket arrangements

More information

VAV TERMINAL BOXES TYPE: BA BT

VAV TERMINAL BOXES TYPE: BA BT Installation dimensions View inlet side View outlet side C G F E ø D A 65 ø8 B 25 Side view Top view 40 150 150 L1 Application ø D 150 Size operating range q (m 3 /h) Min. Max. Nom. 125 90 150-440 500

More information

Alfa Laval Optigo CS. Commercial air coolers - Slim line

Alfa Laval Optigo CS. Commercial air coolers - Slim line Alfa Laval Optigo CS Commercial air coolers - Slim line Optigo CS Alfa Laval Optigo Simply fresh, today and tomorrow Optigo is the Alfa Laval platform for commercial air cooler ranges. Common distinctive

More information

fåçìëíêá~ä=~áê=åççäéêë=qelo pí~åç~êç=åççäéêë=ïáíü=`ì=íìäáåö

fåçìëíêá~ä=~áê=åççäéêë=qelo pí~åç~êç=åççäéêë=ïáíü=`ì=íìäáåö = pí~åç~êç=åççäéêë=ïáíü=`ì=íìäáåö O `çåíéåíë= page Model indication..................................2 Eurovent.......................................2 Capacities......................................2

More information

Swimming Pool CSR2 Heat Recovery Equipment

Swimming Pool CSR2 Heat Recovery Equipment Swimming Pool CSR2 Heat Recovery Equipment LIFETIME WARRANTY OVER 90% HEAT RECOVERY LOW CARBON British manufacturing at its best EcoAir Box is a trademark of IPT +44 (01527) 492770 www.ecoairbox.co.uk

More information

Industrial air coolers for cooling & freezing applications Cu/Al

Industrial air coolers for cooling & freezing applications Cu/Al Goedhart VCI Industrial air coolers for cooling & freezing applications Cu/Al R404A - CO 2 engineering for a better world GEA Heat Exchangers Goedhart VCI The extensive range Goedhart VCI single discharge

More information

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE. TECHNICAL SELECTION DATA PACKAGE UNIT + o C -10 o C 3 THREE PHASE SCROLL TWO STAGE CENTRIFUGAL LOUVRE LIANT SCROLL RESSOR AXIAL UNIT FEATURES SPECIFICATION SUMMARY Scroll Compressor Multiple Speed Outdoor

More information

SERIES JN GILBERTS. Jet Diffusers. Features PUBLICATION DIFFUSERS 8 JUNE 2007

SERIES JN GILBERTS. Jet Diffusers. Features PUBLICATION DIFFUSERS 8 JUNE 2007 PUBLICATION DIFFUSERS 8 JUNE 2007 Features Jet Air Stream Distribution. Wide Directional Adjustment. Long Throw Capability Reversible Diffuser Nozzle Provides full or reduced Jet Pattern. High Volume Capacity.

More information

DRUM JET DIFFUSERS TYPE: DJA DJB DJAP DJBP

DRUM JET DIFFUSERS TYPE: DJA DJB DJAP DJBP TYPE: DJA DJB DJAP DJBP APPLICATION Type DJ As with type AJ diffusers, this product is also designed to project large volumes of air over long distances, but particularly lends itself to sidewall or ductmounting,

More information

COMFORT AIR CURTAIN. SensAir

COMFORT AIR CURTAIN. SensAir COMFORT AIR CURTAIN SensAir SensAir comfort air curtain Revolutionary climate separation The SensAir comfort air curtain sets a new standard in the field of climate separation. The highest level of comfort

More information

UTA STANDARD. Ductable units. Range. Air handling unit with high available static pressure. NEW Eco-Design Filter. V3000 control Fresh air management

UTA STANDARD. Ductable units. Range. Air handling unit with high available static pressure. NEW Eco-Design Filter. V3000 control Fresh air management Ductable units NEW Eco-Design Filter Air handling unit with high available static pressure V3000 control Fresh air management The range of air handling units is designed for suspended ceiling heating and

More information

PVHRU Max Quiet. Engineering Solutions. Packaged Void Heat Reclaim Unit. Acoustic Testing Laboratory College of Science & Technology

PVHRU Max Quiet. Engineering Solutions. Packaged Void Heat Reclaim Unit. Acoustic Testing Laboratory College of Science & Technology AIR HANDLERS LTD PVHRU Max Quiet Packaged Void Heat Reclaim Unit 1262 Acoustic Testing Laboratory College of Science & Technology Engineering Solutions The Company Air Handlers has been trading since May

More information

Highline 260i EC Waterside Fan Coil Unit

Highline 260i EC Waterside Fan Coil Unit Features: Electronically Commutated (EC) fan motor Specific Fan Power of 0.16 to 0.34 at NR Insignificant fan heat gain Designed to operate below NR at External Static Pressures of up to 50Pa Variable

More information

Industrial air coolers THOR. Standard coolers in a revolutionary design

Industrial air coolers THOR. Standard coolers in a revolutionary design Industrial air coolers Standard coolers in a revolutionary design O `çåíéåíë= page Model indication..................................2 Eurovent.......................................2 Capacities......................................2

More information

Making refrigeration greener KELVION KME COMMERCIAL AIR COOLER

Making refrigeration greener KELVION KME COMMERCIAL AIR COOLER Making refrigeration greener KELVION KME COMMERCIAL COOLER Kelvion a tribute to Lord Kelvin Lord Kelvin (1824 1907) formulated the laws of thermodynamics 70 branches and sales partners worldwide More

More information

AC Commercial Fans Edition. ErP ready

AC Commercial Fans Edition. ErP ready AC Commercial Fans 213 Edition ErP ready AC Commercial Fans Axair Fans UK Ltd / 1782 34943 About Axair Fans UK Axair is an independent industrial fan manufacturer and distributor. What we offer : Application

More information

SECTION AXIAL HVAC FANS

SECTION AXIAL HVAC FANS SECTION 233413 - AXIAL HVAC FANS 1. PART 1 GENERAL 1.1. RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Alfa Laval Optigo CD. Commercial air coolers - Dual discharge

Alfa Laval Optigo CD. Commercial air coolers - Dual discharge Alfa Laval Optigo CD Commercial air coolers - Dual discharge Optigo CD Alfa Laval Optigo Simply fresh, today and tomorrow Optigo is the Alfa Laval platform for commercial air cooler ranges. Common distinctive

More information

Composite PEX-AL-PEX Tubing

Composite PEX-AL-PEX Tubing 04/01/11 page 1.1 Composite PEX-AL-PEX Tubing List Per Foot 40190F ½ Composite Tubing x 200.62 40190 ½ Composite Tubing x 250.62 40190A ½ Composite Tubing x 300.62 40190B ½ Composite Tubing x 1000.62 40192

More information

FR Heat Exchanger Unit Heater

FR Heat Exchanger Unit Heater Unit Heater Ruffneck are extra heavy duty (including heavy gauge steel construction) to meet the most demanding service and long life requirements for rugged industrial applications. The Series heaters

More information

Guide Specifications. General. Casing. Coil/Drain pan. Fan/Motor

Guide Specifications. General. Casing. Coil/Drain pan. Fan/Motor Guide Specifications General CR-A series ducted concealed chilled water fan coil units have an air flow range from 45 to 3060 cubic meters per hour with a capacity range from kw up to 9 kw. The CR-A series

More information

Sand Trap Louvers OSTL 300 SERIES. Sand Trap Louvers

Sand Trap Louvers OSTL 300 SERIES. Sand Trap Louvers Model : OSTL GI 341 Description: OPTIMA make Sand Trap Louver is used as pre-filter for the protection of air conditioning plants in area exposed to extreme levels of industrial pollution. It has a high

More information

Louvre systems. Series WL Standard weather louvres. Incorporating. Standard range of single bank louvres as used in countless installations worldwide

Louvre systems. Series WL Standard weather louvres. Incorporating. Standard range of single bank louvres as used in countless installations worldwide Louvre systems Incorporating Series WL Standard range of single bank louvres as used in countless installations worldwide Good resistance to water ingress, with low resistance to airflow Approximately

More information

Concealed Ducted Split Series R22

Concealed Ducted Split Series R22 Concealed Ducted Split Series R22 24-60 MBH Ducted Split with Hermetic Compressor Tropical 50 Hz For more technical information please visit Table of Contents INTRODUCTION 2 NOMENCLATURE 2 UNIT RATING

More information

MAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional

MAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional Y + U I COADIS COMBI High pressure and high ductable units Motor optional is a non independent air conditioning terminal unit for heating and cooling offices and hotels. With reduced dimensions and designed

More information

Centrifugal Cabinet Fans Model BDF. Belt Drive Duct Fan

Centrifugal Cabinet Fans Model BDF. Belt Drive Duct Fan Centrifugal Cabinet s BDF Belt Drive Duct July 007 BDF Belt Drive Duct s Greenheck s Belt Drive Duct s, BDF, provide the industry s best performance and durability. BDF is carefully engineered for efficiency

More information

SUBMITTAL COVER SHEET

SUBMITTAL COVER SHEET SUBMITTAL COVER SHEET PROJECT NAME LOCATION ARCHITECT ENGINEER CONTRACTOR SUBMITTED BY DATE UNIT SUMMARY Quantity Unit Designation Model No. Total Cooling Sensible Cooling Air Ent. Evaporator Air Lvg.

More information

SUBMITTAL COVER SHEET

SUBMITTAL COVER SHEET SUBMITTAL COVER SHEET PROJECT NAME LOCATION ARCHITECT ENGINEER CONTRACTOR SUBMITTED BY DATE UNIT SUMMARY Quantity Unit Designation Model No. Total Cooling Sensible Cooling Air Ent. Evaporator Air Lvg.

More information

HOWORTH EXFLOW 28 PREVENTS AIRBORNE INFECTION TECHNICAL SPECIFICATION. Exflow 28 Technical Specification. Page 1 of 7

HOWORTH EXFLOW 28 PREVENTS AIRBORNE INFECTION TECHNICAL SPECIFICATION. Exflow 28 Technical Specification. Page 1 of 7 HOWORTH EXFLOW 28 PREVENTS AIRBORNE INFECTION TECHNICAL SPECIFICATION Exflow 28 Technical Specification Page 1 of 7 TECHNICAL SUMMARY Terminal Unit size 12-3 ¼ x 12-3 ¼ x 23 ¾ Terminal Unit weight 3527

More information

VC Series. Volume Control Dampers M A N U F A C T U R E R S O F A I R, F I R E A N D S M O K E C O N T R O L P R O D U C T S

VC Series. Volume Control Dampers M A N U F A C T U R E R S O F A I R, F I R E A N D S M O K E C O N T R O L P R O D U C T S V41706 VC Series Volume Control Dampers Roll formed steel blades with three material options DW144 compliant Flanged models with 65mm deep mechanically fixed casings Rectangular spigotted models with 85mm

More information

Ductable Modular Fan Coil Unit VPX. Technical Brochure TM VPX-W.2GB Date : May 2004 Supersedes : TM VPX-W.1GB/08.03

Ductable Modular Fan Coil Unit VPX. Technical Brochure TM VPX-W.2GB Date : May 2004 Supersedes : TM VPX-W.1GB/08.03 Ductable Modular Fan Coil Unit VPX Technical Brochure TM VPX-W.2GB Date : May 2004 Supersedes : TM VPX-W.1GB/08.03 Design Features Presentation The VPX fan coil unit has been specially designed to meet

More information

Küba SG industrial

Küba SG industrial 66 Küba Blue Line : Specific advantages The is a master of customisation. No matter how great the demand for power, the is the answer. Its versatility allows the Küba SG industrial to master the most complex

More information

Performance. Sound Levels. Impellers. Motors. Accessories

Performance. Sound Levels. Impellers. Motors. Accessories EuroSeries (ESP) Die cast aluminium impellers Fully speed controllable Air Volumes up to 13.89m 3 /s Sizes 250 to 1000 dia protected to IP54 Operating Temperatures from -40 C up to +70 C Insulation Class

More information

1 AIR HANDLING UNIT TYPE AIR ACCESS 75

1 AIR HANDLING UNIT TYPE AIR ACCESS 75 SUPPLY 1 AIR HANDLING UNIT TYPE AIR ACCESS 75 Location : EXTERNAL Position : SIDE BY SIDE SLIDING PANELS for COMPLETE ACCESSIBILITY MULTI SERVICE BULKHEAD for HYDRAULIC AND ELECTRICAL CONNECTIONS Self-supporting

More information

Mancoolers Models MCY, MCB, MCP

Mancoolers Models MCY, MCB, MCP Mancoolers s MCY, MCB, MCP October 2007 Mancoolers Greenheck MC Mancooler fans are direct drive, tube axial fans designed for applications where localized air direction and circulation are required. Mancoolers

More information

KVA POWERHOUSE RANGE 1250 KVA 1700 KVA

KVA POWERHOUSE RANGE 1250 KVA 1700 KVA KVA POWERHOUSE RANGE 1250 KVA 1700 KVA 50 hz Three phase 380-415 v Model Engine Alternator Manufacturing country of engine & alternator PRP Output ESP Output Kva Kw Kva 380v/400- Kw 415v 46TWG2A PI734B

More information

Küba Green Line. Küba comfort DP. Ceiling Air Cooler.

Küba Green Line. Küba comfort DP. Ceiling Air Cooler. Küba Green Line 47 Ceiling Air Cooler GEA Küba Application Benefits for Contractors and Operators Expanded capacity range Up to 28 kw Low draught levels Integrated air baffle plate for low air speed in

More information

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ DESCRIPTION FEATURES

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ DESCRIPTION FEATURES (791) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ H1CE180 & 240 15 AND 20 NOMINAL TONS (60 HZ) 13 AND 17-1/2 NOMINAL TONS (50 HZ) SUNLINE 2000 DESCRIPTION These Sunline 2000 units are completely

More information

FR Series Heat Exchanger Unit Heater

FR Series Heat Exchanger Unit Heater FR Series Heat Exchanger Unit Heater FR Unit Heaters are extra heavy duty (including heavy gauge steel construction) to meet the most demanding service and long life requirements for rugged industrial

More information

Alfa Laval Optigo CC. Commercial air coolers - Single discharge. Extended range featuring draw-through & blow-through models

Alfa Laval Optigo CC. Commercial air coolers - Single discharge. Extended range featuring draw-through & blow-through models Alfa Laval Optigo CC Commercial air coolers - Single discharge Extended range featuring draw-through & blow-through models Optigo CC(B) Alfa Laval Optigo Simply fresh, today and tomorrow Optigo is the

More information

@Perkins. Technical Data Series TAG1A TAG2A TAG3A. Diesel Engine - Electropak. Basic technical data

@Perkins. Technical Data Series TAG1A TAG2A TAG3A. Diesel Engine - Electropak. Basic technical data Technical Data Basic technical data Number of cylinders.................................................... 6 Cylinder arrangement................................... Vertical, In line Cycle....................................4

More information

General purpose cast iron frame motors. The right choice for optimal durability, efficiency and performance. SIMOTICS NEMA Low Voltage Motors

General purpose cast iron frame motors. The right choice for optimal durability, efficiency and performance. SIMOTICS NEMA Low Voltage Motors General purpose cast iron frame motors The right choice for optimal durability, efficiency and performance SIMOTICS NEMA Low Voltage Motors www.usa.siemens.com/motors Siemens SIMOTICS low voltage cast

More information

AIR CURTAINS AIR CHAMBER DESIGN

AIR CURTAINS AIR CHAMBER DESIGN AIR CURTAINS AIR CHAMBER DESIGN Pittsburgh, PA Akron, OH Atlanta, GA Los Angeles, CA INDEX How an Air Curtain Works...3 Making an Air Curtain...3 Choosing The Right Air Curtain...4-5 Energy Saving & Return

More information

500-YH SINGLE DUCT AIR TERMINAL UNIT FORM EG1 (1101)

500-YH SINGLE DUCT AIR TERMINAL UNIT FORM EG1 (1101) 500-YH SINGLE DUCT AIR TERMINAL UNIT FORM 130.12-EG1 (1101) Table of Contents General Description.......................................................................3 500-YH Features........................................................................4-5

More information

Liv-Elir d.o.o. Contact Info: Tel/Fax.: Mob.: Mail: REPAIR AND SERVICE / PRODUCTION

Liv-Elir d.o.o. Contact Info: Tel/Fax.: Mob.: Mail: REPAIR AND SERVICE / PRODUCTION REPAIR AND SERVICE / PRODUCTION REPAIR AND SERVICE Asynchronous, synchronous and collector machines of low and high voltage: Production of coil insulation class B, F, H Production of coil for voltage level

More information

Features: Concealed installation. Compact design. Available in electric, LPHW or ambient.

Features: Concealed installation. Compact design. Available in electric, LPHW or ambient. Features: Concealed installation. Compact design. Available in electric, LPHW or ambient. Grille can be supplied in a large range of colours. Energy saving controls option available. Application The Diffusion

More information

GUIDE SPECIFICATIONS. ES Series R-410A

GUIDE SPECIFICATIONS. ES Series R-410A GUIDE SPECIFICATIONS ES Series R-410A GENERAL Units shall be performance certified to ISO standard 13256-1 for Water Loop Pump, Ground Water Pump and Ground Loop Pump applications. Units shall be Underwriter

More information

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm Product Data 42BH System Fan Coil 800 to 4000 Cfm Satisfy All Your Design Requirements with Carrier s Versatile 42BH Fan Coil Unit A selection of 6 sizes covers capacities from 800 to 4000 cfm Choice of

More information

5 to 100 Ton Capacity Custom Capacities Available

5 to 100 Ton Capacity Custom Capacities Available COIL COMPANY 5 to 100 Ton Capacity Custom Capacities Available LRC s remote Air Cooled Fluid Coolers (AFC) provide optimum heat transfer efficiency and are manufactured for years of dependable service.

More information

Slot diffusers, Round duct diffusers. IMP Klima

Slot diffusers, Round duct diffusers. IMP Klima , Round duct diffusers 04 Round duct diffusers 176 , Round duct diffusers SLOT DIFFUSERS, ROUND DUCT DIFFUSERS SWIRL DIFFUSERS, VARIABLE SWIRL DIFFUSERS CIRCULAR DIFFUSERS, SQUARE DIFFUSERS VENTILATING

More information

Centrifugal performance characteristics with axial flow pattern: RADAX VAR

Centrifugal performance characteristics with axial flow pattern: RADAX VAR High pressure in-line mixed-flow fans RADAX VAR Centrifugal performance characteristics with axial flow pattern: RADAX VAR COMPACT PRESSURE-RESISTANT UNIVERSAL In their compact casing, the RADAX VAR impellers

More information

TVFC Dry and adiabatic cooling

TVFC Dry and adiabatic cooling Dry and adiabatic cooling Key benefits Largest adiabatic capacity Highest degree of redundancy Unrivalled reliability cooler characteristics Counter flow, adiabatic pre-cooling, axial fan, induced draft

More information

MEDIUM PROFILE UNIT COOLERS Technical Guide

MEDIUM PROFILE UNIT COOLERS Technical Guide BN-MPTB August 2016 Replaces BN-MPTB, June 2015 MEDIUM PROFILE UNIT COOLERS Technical Guide s BMA Air Defrost BME/BML Electric Defrost BMG/BMF Hot Gas Defrost heatcraftrpd.com Table of Contents Nomenclature...2

More information

Low Profile Unit Cooler

Low Profile Unit Cooler Low Profile Unit Cooler Publication No. 100.13 January, 2004 MEA Air Defrost - 3,900 to 39,000 BTUH Electric Defrost - 3,600 to 28,000 BTUH Hot Gas Defrost - 3,600 to 28,000 BTUH Small to Medium Walk -

More information

SUPPLY AND RETURN AIR GRILLES TYPE: AS/GS120 AS/GS130

SUPPLY AND RETURN AIR GRILLES TYPE: AS/GS120 AS/GS130 SUPPLY AND RETURN AIR GRILLES TYPE: AS/GS120 AS/GS130 Installation dimensions AS/GS120 AS/GS130 Application The grille type AS / GS is used for the supply and exhaust of cooled or heated air in facilities

More information

Vent-Axia Sabre Sickle Roof Fans (VSR)

Vent-Axia Sabre Sickle Roof Fans (VSR) Vent-Axia Sabre Sickle Roof Fans (VSR) Features and Benefits High performance roof sickle fan Fully assembled cowl. Optional backdraught shutters and birdguard Moulded from recyclable polymeric material,

More information

CENTRIFUGAL FAN COIL UNIT VCE

CENTRIFUGAL FAN COIL UNIT VCE CENTRIFUGAL FAN COIL UNIT VCE 0,51 kw 11,00 kw 0,85 kw 23,75 kw 129 m 3 /h 2003 m 3 /h VCE DESIGN QUALITY COMFORTRELIABILITY 3VERSION12 SIZE DESIGN VCEx0 vertical with cabinet Air intake: bottom vertical

More information

Alfa Laval Optigo CD. Commercial air coolers - Dual discharge

Alfa Laval Optigo CD. Commercial air coolers - Dual discharge Alfa Laval Optigo CD Commercial air coolers - Dual discharge Optigo CD Alfa Laval Optigo Simply fresh, today and tomorrow Optigo is the Alfa Laval platform for commercial air cooler ranges. Common distinctive

More information

TURNING AIR INTO SOLUTIONS. DIRECT DRIVE EXHAUST & SUPPLY PANEL FANS. Model TCPE

TURNING AIR INTO SOLUTIONS. DIRECT DRIVE EXHAUST & SUPPLY PANEL FANS. Model TCPE TURNING AIR INTO SOLUTIONS. DIRECT DRIVE EXHAUST & SUPPLY PANEL FANS Model TCPE CATALOG 4800 February 2017 PANEL FANS Overview TCPE TCPE panel fans are direct drive panel fans designed for low static pressures.

More information

NISSENS COOLING SOLUTIONS. Cooling for Industrial Applications Solutions and Technologies

NISSENS COOLING SOLUTIONS. Cooling for Industrial Applications Solutions and Technologies NISSENS COOLING SOLUTIONS Cooling for Industrial Applications Solutions and Technologies World-Class Customization for Any Product Application PLATE & BAR COOLERS Throughout 90 years, Nissens has built

More information

Hydropac. Waterside Control Fan Coil Units For Horizontal and Vertical Applications. June Hydropac. Features

Hydropac. Waterside Control Fan Coil Units For Horizontal and Vertical Applications. June Hydropac. Features June 2003 Hydropac Hydropac Waterside Control Fan Coil Units For Horizontal and Vertical Applications Features Flush panel extra rigid construction. Low noise levels. Eleven speed transformer. Full acoustic

More information

AIR COOLED CHILLERS WATER COOLED CHILLERS

AIR COOLED CHILLERS WATER COOLED CHILLERS AIR COOLED CHILLERS WATER COOLED CHILLERS STANDARD UNIT SPECIFICATIONS OF COMMERCIAL AIR COOLED CHILLERS General Description & Assembly Air Cooled Chillers are commercial packaged systems complete with

More information

Warm. DFC Direct Fired Gas Heating System. Applied Air. Keeps You. Technical Guide for: Outdoor Mounted Units To 100,000 CFM And 14M BTUH

Warm. DFC Direct Fired Gas Heating System. Applied Air. Keeps You. Technical Guide for: Outdoor Mounted Units To 100,000 CFM And 14M BTUH TGDFC-6 DFC Direct Fired Gas Heating System Technical Guide for: Outdoor Mounted Units To 0,000 CFM And 14M BTUH Applied Air Keeps You Warm Featuring the Patented AdaptAire controlled Circulation System

More information

High Profile Evaporator

High Profile Evaporator High Profile orator PRODUCT DATA & INSTALLATION Bulletin K30-KHPHG-PDI-3 Part # 1081591 PRODUCT SUPPORT web: k-rp.com/khp email: evaps@k-rp.com call: 1-844-893-3222 x520 scan: Low & Medium Hot Gas Defrost

More information

Standard features. Optional features

Standard features. Optional features FABRIQUÉ AU CANADA MADEIN CANADA Standard features 3/8 inch inner grooved copper tubing up to 5 fan long units. Reduced refrigerant charge with high heat-transfer. Tube sheets with oversized holes and

More information

CHP

CHP Packaged Unit Heat Pump CHP16-024-030-036-048-060 2-5 Ton Cooling 23,000-57,500 Btuh Heating 12,800-85,300 Btuh (5-25 kw) Optional Electric Heating FEATURES Designed for outdoor rooftop or ground level

More information

DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS SUPPLY AIR PLENUMS

DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS SUPPLY AIR PLENUMS DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS These completely assembled units include a well-insulated cabinet, a DX cooling coil

More information

Section 5 AIR - COOLED CONDENSING UNITS MODEL PC 05Z TO PC NOMINAL COOLING CAPACITY RANGE 56.6 TO 772 MBH

Section 5 AIR - COOLED CONDENSING UNITS MODEL PC 05Z TO PC NOMINAL COOLING CAPACITY RANGE 56.6 TO 772 MBH AIR - COOLED CONDENSING UNITS MODEL PC 05Z TO PC 80-01 NOMINAL COOLING CAPACITY RANGE 56.6 TO 772 MBH 14 FEATURES MODEL PC 05Z TO PC 30-02 CABINET: Cabinets are constructed of heavily zinc coated galvanized

More information

THINK COLD. THINK LARKIN. WAREHOUSE/INDUSTRIAL UNIT COOLER

THINK COLD. THINK LARKIN. WAREHOUSE/INDUSTRIAL UNIT COOLER Bulletin LH-02 August 2002 (Replaces LH-98, March 1998) THINK COLD. THINK LARKIN. WAREHOUSE/INDUSTRIAL UNIT COOLER Warehouse/Industrial Unit Coolers Larkin introduces it s latest line of warehouse/industrial

More information

KLIMA Active Chilled Beams

KLIMA Active Chilled Beams KLIMA 2 600 Active Chilled Beams 0 Index Subject Page Index 1 Introduction 2 General description 3-4 Product features 5-6 Dimensions 7 Performance data 8-11 Selection example 12 Guide specifications 13

More information

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ)

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ) 550.39-TG1YI (994) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS H5CE090 & H3CE120 7.5 AND 10 NOMINAL TONS (World 50HZ) HCE090 SUNLINE 2000 DESCRIPTION These Sunline 2000 units are completely assembled, piped

More information

Heat Exchangers. Evaporator Catalogue

Heat Exchangers. Evaporator Catalogue Heat Exchangers Evaporator Catalogue Version 30: January 2015 Heat Exchangers Thermocoil Catalogue V30 2015 Evaporators Page 2 INDEX EVAPORATORS PAGE Evaporator Design and Info 4 Quick Find List (Sorted

More information

500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT FORM EG3 (404)

500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT FORM EG3 (404) 500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT Table of Contents Introduction...3 500-YVI Features...4-5 Dimensional Data...6-7 ARI Rating Points...8 Statement of Standard Test Conformity...8 Motor Amperage

More information

Industrial air cooler VCI Cooling/Freezing

Industrial air cooler VCI Cooling/Freezing Industrial air cooler VCI Cooling/Freezing Cu/Al - R404A GEA Refrigeration Goedhart Goedhart VCI The extensive range Goedhart VCI single discharge ceiling mounted industrial air coolers are available with

More information

Rittling Architectural Enclosures. Catalog. CleanAir

Rittling Architectural Enclosures. Catalog. CleanAir Rittling Architectural s Catalog Heating Cooling Fresh Air Clean CleanAir Air i Zehnder everything you need to create a comfortable, healthy and energy-efficient indoor climate Heating, cooling, fresh

More information

Centrifugal Cabinet Fans Model BCF Belt Drive Low-Profile

Centrifugal Cabinet Fans Model BCF Belt Drive Low-Profile Centrifugal Cabinet s BCF Belt Drive Low-Profile May 2007 BCF Belt Drive Cabinet s Greenheck belt drive low-profile cabinet fans, BCF, are designed for efficiency and reliability in supply, exhaust or

More information

C O L M A N. Air Distribution LINEAR BAR GRILLES T SERIES SERIES

C O L M A N. Air Distribution LINEAR BAR GRILLES T SERIES SERIES C O L M A N Air Distribution E N G I N E E R E D A I R P R O D U C T S LINEAR BAR GRILLES T SERIES T SERIES C O L M A N Air Distribution E N G I N E E R E D A I R P R O D U C T S LINEAR BAR GRILLES T SERIES

More information

Silent centrifugal air heater hot water supply

Silent centrifugal air heater hot water supply Large range : 5 to 120 Flows : 900 to 14000 m 3 /h Numerous accessories Design integrating perfectly in public buildings USE Operation in zones ES and S Extra silent and silent Forced air heating for premises

More information

Calculation of external available Pressure. [m/s] 0,41 0,62 0,82 1,03 1,23 1,44 1,64 1,85 2,05 2,47 2,88 3,29 3,7

Calculation of external available Pressure. [m/s] 0,41 0,62 0,82 1,03 1,23 1,44 1,64 1,85 2,05 2,47 2,88 3,29 3,7 Calculation of external available Pressure Page 1 Size: 1 Air flow volume [m³/h] 4 6 8 1 12 14 16 18 2 24 28 32 36 1. Criterion flow velocity (Ref. 2 C) Do not design units in conditions acc. to white

More information

Adriatic for individually suspended installation Exposed active climate beam with cooling, heating and ventilation

Adriatic for individually suspended installation Exposed active climate beam with cooling, heating and ventilation Adriatic for individually suspended installation Exposed active climate beam with cooling, heating and ventilation ADRIATIC VF Climate beam Adriatic Adriatic is an enclosed climate beam with integrated

More information

ATZAF DOUBLE INLET CENTRIFUGAL FANS WITH AIRFOIL BACKWARD CURVED BLADES

ATZAF DOUBLE INLET CENTRIFUGAL FANS WITH AIRFOIL BACKWARD CURVED BLADES ATZAF DOUBLE INLET CENTRIFUGAL FANS WITH AIRFOIL BACKWARD CURVED BLADES COMEFRI USA: Manufacturing and Warehouse facilities in Hopkinsville, KY. Total facility: 125,000 sq.ft. Producing centrifugal fans

More information