1 Blower Business Group TURBO BLOWERS 4-44 OSI ,000 CFM Bulletin 2300 June 1998 FEATURES Widest range of sizes available in the turbo blower market to meet the needs of the combustion, drying, and process industries. Energy efficient 60 hertz motors on all blowers 5 hp and above that meet or exceed the 1992 Energy Act which became effective in High volume blowers are available in 1800 rpm or 3600 rpm with single or multiple stage designs to meet the needs of the most demanding situations. Horsepower and impeller selection designed to achieve flat performance curves to minimize variations over the operating range of the blower. Blower shown with optional 2923 Filter Full array of accessories include filters, silencers, filter silencers, inlet and outlet adapters, flexible sleeves, inlet vane dampers, AC frequency drives, combination motor starters and fusible disconnects. These options offer the protection needed to keep operational costs down while increasing blower life expectancy. SELECTION Pressures and capabilities are shown on the succeeding pages of this bulletin. While motors with 1.15 service factors are more and more available, it is wise to allow some capacity safety margin when picking a blower for a calculated cfm requirements--unanticipated piping leaks, variations in burner capacity, and other unforeseen factors could cause motor overload unless there is some cushion. Without prior knowledge of leakage and other conditions, a 10% safety margin is considered minimum. It is also important to allow for pressure losses in piping, fittings, and valves, which reduce pressure available at the burner (or other end use). Typical 2300 Blower Installation Altitude and preheated air effect blower ratings--pressure, capacity, and horsepower. For blower selection/performance at altitudes significantly above sea level, the blower section of the North American Combustion Handbook is recommended. Generally, standard motors can be used up to 3300 feet elevation; special construction is recommended above 3300 feet. See Bulletin 2600 if Blower will handle air hotter than 250 F. CONSTRUCTION All metal construction including mild steel, cast aluminum, or corrosion resistant stainless steel create a nearly indestructible blower allowing for years of trouble free service. Specially fabricated aluminum or steel impeller designs reduce vibration, lengthen motor life, and lower energy consumption due to lightweight construction technology. Individual impeller dynamics assured by either single or two plane balancing to minimize vibration and assure longer bearing life. Strategically positioned bolt hole locations allow for in-field repositioning of air flow discharge. Standard shaft motors on most single stage blowers reduce replacement downtime in the field. Standard inlet includes a guard. Threaded or SW unthreaded adapters can be specified in place of the guard for mounting optional filters or silencers, or if a 2947 blower sleeve will be used to accommodate inlet piping. Blowers with 8" or larger discharge are supplied with SW unthreaded adapter suitable for a flexible sleeve or welding. Blowers with 6" or smaller discharge normally have a threaded (fpt) flange, but the SW unthreaded discharge can be specified at no extra cost.

2 BLOWER DESIGNATION EXPLANATION example: /1-T2D Standard discharge positions (viewed from motor side). See Supplement for other positions series drive: Direct (D) nominal pressure drive: Coupled (C) case designation drive: V-belt (V) number of stages horsepower motor TEFC (T) less motor (L) Approx. weight, lb & cfm at Inlet Outlet Hertz Hertz Hertz Nominal 100% of 3600 rpm nominal nominal Intake Intake Filter Direct V-Belt Coupled pressure Blower motor TEFC pipe pipe Intake Filter Silencer Silencer drive drive drive osi/"wc designation rating 1.15 SF motor size size designation designation (D) ( V ) (C) 4 osi 6.92"wc 8 osi.84"wc /1-T T.33-C36T1SC A None A /3-T.5 55 T.50-C36T1L4.0C A None A /1-T.5 60 T.50-C36T1SC A " A /1-T T.75-C36T1SC A " A /1-T1 220 T1.0-C36T1SC A " A /1-T1 250 T1.0-C36T1SC A " A /1-T T1.5-C36T1SC A None A /1-T2 460 T2.0-C36T1SC A A /1-T3 770 T3.0-C36T1SC A A /1-T T5.0-C36T1SC A A /1-T T7.5-C36T1SC A A /1-T T10-C36T1SC A A /4-T.5 80 T.50-C36T1L A None A /1-T T.75-C36T1SC A " A /1-T1 150 T1.0-C36T1SC A " A /1-T T1.5-C36T1SC B " B /1-T2 400 T2.0-C36T1SC A None A /1-T3 580 T3.0-C36T1SC A A /1-T T5.0-C36T1SC A A osi /1-T T7.5-C36T1SC A A "wc /1-T T10-C36T1SC A A /1-T T50-C36T1SD / / /1-T T60-C36T1SD / / /1-T T75-C36T1SD / / /1-T T100-C36T1SD Consult Cleveland /1-T T125-C36T1SD /4-T.5 50 T.50-C36T1L5.2C A None A /1-T1 100 T1.0-C36T1SC A " A /1-T T1.5-C36T1SC B " B /1-T2 340 T2.0-C36T1SC B " B /1-T3 450 T3.0-C36T1SC A A /1-T5D 850 T5.0-C36T1SC A A /1-T T7.5-C36T1SC A A osi /1-T T10-C36T1SC A A "wc /1-T T15-C36T1SC B B /1-T T20-C36T1SD A A /1-T T25-C36T1SD A A /1-T T30-36CT1SD B B /1-T T40-C36T1SD / / /1-T T50-C36T1SD / / /1-T T60-C36T1SD / / osi 27.68"wc /2-T1 90 T1.0-C36T1L5.5C A None A /2-T T1.5-C36T1L6.7C A " A /2-T T1.5-C36T1L6.7C B " B /1-T2 150 T2.0-C36T1SC B " B /2-T2 220 T2.0-C36T1L6.7C B None B /1-T3 290 T3.0-C36T1SC A A /2-T3 340 T3.0-C36T1L6.7C A None A /1-T3 340 T3.0-C36T1SC A " A Bulletin 2300 Page 2

3 Approx. weight, lb & cfm at Inlet Outlet Hertz Hertz Hertz Nominal 100% of 3600 rpm nominal nominal Intake Intake Filter Direct V-Belt Coupled pressure Blower motor TEFC pipe pipe Intake Filter Silencer Silencer drive drive drive osi/"wc designation rating 1.15 SF motor size size designation designation (D) (V) (C) /2-T3 350 T3.0-C36T1L7.0C A A /2-T5 600 T5.0-C36T1L7.0C A A /1-T5 600 T5.0-C36T1SC A A /1-T5 620 T5.0-C36T1SC A A /2-T T7.5-C36T1L8.3C A A /1-T T7.5-C36T1SC A A /1-T T7.5-C36T1SC A A /2-T T10-C36T1L8.3C A A osi 27.68"wc /1-T10 00 T10-C36T1SC B 9-35A B /1-T T15-C36T1SC A A /1-T T15-C36T1SC B 9-35A B /1-T T20-C36T1SC A A /1-T T25-C36T1SC A A /1-T T30-C36T1SC A A /1-T T40-C36T1SD A A /1-T T50-C36T1SC / / /1-T T60-C36T1SD / / /1-T T75-C36T1SD / / /1-T T100-C36T1SD / / /2-T T1.5-C36T1L6.7C A None A /2-T2 170 T2.0-C36T1L6.7C B " B /2-T3 290 T3.0-C36T1L7.0C B " B /2-T5 500 T5.0-C36T1L7.0C A A /2-T T7.5-C36T1L7.0C A A /1-T T10-C36T1SC B 9-35A B /1-T T15-C36T1SC A A /1-T T15-C36T1SC B 9-35A B /1-T T20-C36T1SC A A osi /1-T T25-C36T1SC A A "wc /1-T T30-C36T1SC A A /1-T T40-C36T1SC A A /1-T T50-C36T1SC / / /1-T T60-C36T1SD / / /1-T T75-C36T1SD / / /1-T T100-C36T1SD / / /1-T T125-C36T1SD / / /1-T T150-C36T1SD / / /3-T T1.5-C36T1L9.0C A None A /3-T2 120 T2.0-C36T1L9.0C A " A /2-T3 210 T3.0-C36T1L7.0C B " B /2-T5 370 T5.0-C36T1L7.0C A A osi 41.52"wc /2-T T7.5-C36T1L7.0C A A /2-T T10-C36T1L8.3C A A /2-T T15-C36T1L8.3C A A /1-T T20-C36T1SC A A /1-T T25-C36T1SC A A /1-T T30-C36T1SC A A /1-T T40-C36T1SC A A /1-T T50-C36T1SC / / /1-T T60-C36T1SC / / /1-T T75-C36T1SD / / /1-T T100-C36T1SD / / /1-T T125-C36T1SD / / /1-T T150-C36T1SD / / /3-T3 90 T3.0-C36T1L10.6C B None B osi /3-T5 260 T5.0-C36T1L10.6C B " B "wc /2-T T7.5-C36T1L8.3C A A /2-T T10-C36T1L8.3C A A Bulletin 2300 Page 3

4 Bulletin 2300 Page 4 Approx. weight, lb & cfm at Inlet Outlet Hertz Hertz Hertz Nominal 100% of 3600 rpm nominal nominal Intake Intake Filter Direct V-Belt Coupled pressure Blower motor TEFC pipe pipe Intake Filter Silencer Silencer drive drive drive osi/"wc designation rating 1.15 SF motor size size designation designation (D) (V) (C) /2-T T15-C36T1L8.3C A A /2-T T20-C36T1L10.0C A A /2-T T25-C36T1L10.7C A A /2-T T30-C36T1L10.7C A A /2-T T40-C36S1L10.7C A A osi 55.36"wc /2-T T50-C36T1L12.0C A A /2-T T60-C36T1L12.0D A A /1-T T75-C36T1SD /37 16/ / /1-T T100-C36T1SD /37 16/ / /1-T T125-C36T1SD /37 16/ / /1-T T150-C36T1SD /37 18/ / osi 76.12"wc /3-T T15-C36T1L.5C A A /3-T T20-C36T1L.5C A A /2-T T30-C36T1L10.7C A A /2-T T40-C36S1L10.7C A A /2-T T50-C36S1L10.7C A A rpm /1-T T10-C18T1SC A A /1-T T15-C18T1SC A A /1-T T20-C18T1SC / / osi.84"wc /1-T T25-C18T1SC / / /1-T T30-C18T1SC / / /1-T T40-C18T1SC /47 24/ / /1-T T50-C18T1SC /47 24/ / osi /1-T T40-C18T1SC / / "wc /1-T T50-C18T1SC / / /1-T T20-C18T1SC A A /1-T T25-C18T1SC A A osi /1-T T30-C18T1SC / / "wc /1-T T40-C18T1SC / / /1-T T40-C18T1SC / / /1-T T50-C18T1SC / / /1-T T20-C18T1SC A 16/ A /1-T T25-C18T1SC A 16/ A osi /1-T T30-C18T1SC A 16/ A "wc /1-T T40-C18T1SC /41 16/ / /1-T T50-C18T1SC /41 16/ / /1-T75V T75-C18T1SD /47 24/ / osi 34.6"wc 24 osi 41.52"wc 32 osi 55.36"wc /1-T T25-C18T1SC A A /1-T T30-C18T1SC A A /1-T T40-C18T1SC A A /1-T T50-C18T1SC / / /1-T T60-C18T1SD / / /1-T30V 2300 T30-C18T1SC A A /1-T40V 3500 T40-C18T1SC A A /1-T50V 4700 T40-C18T1SC A A /1-T60V 6200 T60-C18T1SD / / /1-T75V 7900 T75-C18T1SD / / /2-T75C 4500 T75-C18T1SD A A /2-T100C 6200 T100-C18T1SD / / /2-T125C 7100 T125-C18T1SD / / osi /2-T75C 3800 T75-C18T1SD A A "wc /2-T100C 5600 T100-C18T1SD / / Printed in USA WARNING: Situations dangerous to personnel and property can develop from incorrect operation of combustion equipment. North American urges compliance with National Safety Standards and Insurance Underwriters recommendations, and care in operation. North American Mfg. Co., 4455 East 71st Street, Cleveland, OH USA, Phone , Facsimile sales@namfg.com l NA700-B2300

5 Series 2300 DIRECT DRIVE TURBO BLOWERS Dimensions 2300-D November 2000 C L A Discharge Nominal Pipe Size-- female pipe thread for 6" and smaller, unthreaded pipe (SW) for 8" and larger. DIMENSIONS SHOWN ARE SUBJECT TO CHANGE. PLEASE OBTAIN CERTIFIED PRINTS FROM NORTH AMERICAN MFG. CO. IF SPACE LIMITATIONS OR OTHER CONSIDERATIONS MAKE EXACT DIMENSION(S) CRITICAL. All dimensions are in inches. Dimensions shown apply only to blowers with T-frame motors. Consult North American Mfg. Co. for dimensions of blowers with other motors. Blower Designation«A B C D E F G H J K L P Q R S T U V Z* F+K G+K /1-.3D / /8 7 / / / /4 5 9 / / /8 n 3 / /16 3 / / / /1-10D /8 5 1 / / / / / / /4 9 3 / / /432 1 / / / / /3-T.5D / / / / / /4 5 9 / / /8 n 3 / /16 3 / / / /1-.5D /8 6 3 / /8 1 / /4 8 3 / / / /2 3 5 /8 3 / /16 / /8 22 / /1-.75D /8 6 3 / /8 1 / /4 8 3 / / / /2 3 5 /8 3 / /16 / /8 22 / /1-1D /8 6 3 / /8 1 / /4 8 3 / / / /2 3 5 /8 3 / /16 / /8 22 / /1-1D / / / /4 8 1 / / / /2 4 3 / /2 / /8 22 / /1-1.5D / / / /4 8 1 / / / /2 4 3 / /2 / /16 22 / /1-2D /8 4 7 / / /16 3 /4 9 1 / / /4 3 / / / / / /1-3D /8 4 7 / / /16 3 /4 9 1 / / /4 3 / / / / /1-5D / / / / / / / /8 6 3 /8 6 7 /8 3 / /4 1 1 /2 7 / / / /1-7.5 d D / / / / / / / /8 6 3 /8 6 7 /8 3 / /4 1 1 / / / /1-7.5 t D / / / / / / / / /8 3 / /4 1 1 /2 7 / / / /1-10D / / / / / /2 7 / /4 7 1 /4 8 9 /16 3 / / /4 2 1 / / / /1-10D /2 5 1 / / / / / / /4 9 3 / / / / / / /1-15D /2 5 1 / / / / / / /4 9 3 / / / / / / /1-20D /2 5 1 / / / / / / /4 9 3 / / / / / / / /1-25D /2 7 1 / / / / / / /4 9 3 / / / / / / /1-30D /2 7 1 / / / / / / /4 9 3 / / / / / / / /1-40D / / / / / / / / /8 4 5 /16 1 / / / /1-50D / / / / / / / / /8 4 5 / / /16 «Explanation of designation: /1-.3D means Series 2300, 4 osi pressure, inner housing no. 11, 1 stage, 1 /3 hp motor, direct drive. d With drip-proof motor, if dimensions are different from TEFC. t With TEFC motor, if dimensions are different from drip-proof. * Z = Motor overhang for TEFC motors. There is no overhang for drip-proof motors, except /1-40D and /1-40D which overhang 1 /2". Listed T & U dimensions are for SW inlet. For threaded inlet, T is 5 /16" for inner housing no. 11, 1 /2" for others. If S is greater than 6", threaded inlet is not available. SW discharge (unthreaded pipe) is standard and is included in F. ndischarge C L is 10 9 /16" from farthest base hole, for inner housing no. 11. Female pipe thread is standard. If SW discharge (unthreaded pipe) is specified, add 3 1 /4" to F. I 5 holes when No. 4 discharge is furnished. Number 4 discharge position, straight down, can be furnished on special order, a notch having to be cut out of the base at time of assembly, except for blowers with #11 or #35 cases, no modification is required.

6 C L A Discharge Nominal Pipe Size-- female pipe thread for 6" and smaller, unthreaded pipe (SW) for 8" and larger. All dimensions are in inches. Dimensions shown apply only to blowers with T-frame motors. Consult North American Mfg. Co. for dimensions of blowers with other motors. Blower Designation«A B C D E F G H J K L P Q R S T U V Z* F+K G+K /4-T.5D / / /4 7 3 / / /4 5 9 / / /8 n 3 / / / / /1-.75D 3 2 / / / / / / /4 4 5 /16 3 / / /1-1D 4 2 / / / / / / /4 4 5 /16 3 / / /1-1.5D 6 2 / / / / / / /4 4 5 /16 3 / /16 / / / /1-2D 6 2 / / / / / / /4 4 5 /16 3 / /16 / / / /1-3D /8 5 1 / / /8 17 / / / / /16 3 / /8 1 3 / / /1-5D /8 5 1 / /16 15 / / / / / /16 3 / /8 1 3 / / /1-7.5D /4 7 3 / / / / /8 3 / / / /16 3 / /4 1 1 /2 / / / /1-10D / / / / / /2 7 / /4 7 1 /4 8 9 /16 3 / / /4 2 3 / / / /1-40D / / / / / / / / /16 / / / /1-50D / / / / / / / / / / / /4-T.5D / / /4 7 3 / / /4 5 9 / / /8 n 3 / / / / /1-1D 3 2 / / / / / / /4 4 5 /16 3 / / /1-1.5D 4 2 / / / / / / /4 4 5 /16 3 / / /1-2D 6 2 / / / / / / /4 4 5 /16 3 / /16 / / / /1-3D /8 5 1 / / /8 17 / / / / /16 3 / /8 1 3 / / /1-5D /8 5 1 / /16 15 / / / / / /16 3 / /8 1 3 / / /1-7.5D /4 7 3 / / / / /8 3 / / / /16 3 / /4 1 1 /2 / / / /1-10D /4 7 3 / / / / /8 3 / / / /16 3 / /4 1 1 /2 2 1 / / / /1-15 d D /8 5 3 /422 1 / / / /2 7 / /4 7 1 /4 8 9 /16 3 / / /4 3 1 / / / /1-15 t D /8 9 3 / / / / /2 7 / /4 8 1 /2 9 1 /16 3 / / /4 3 1 /4 1 / / / /1-20D / / / / / / / / / / / / / / / /1-25D / / / / / / / / / / / / / / / /1-30D / / / / / / / / / / / / /16 5 / / / /1-40D / / / / / / / / /16 1 / / / /1-40D / / /4 45 / / / / / / / / / / / / / /1-50D / / / / / / / / / / / /2-1D / / /8 1 / /4 8 3 / / / /2 3 5 /8 3 / / /2-1.5D / / /8 1 / /4 8 3 / / / /2 3 5 /8 3 / / /2-1.5D / / / /4 8 1 / / / /2 4 3 / / /2-2D / / / /4 8 1 / / / /2 4 3 / / /1-2D /4 6 1 / /16 1 / / / / /4 4 5 /16 3 / / /1-3D /4 6 1 / / / / / / /4 4 5 /16 3 / /8 / /8 22 /16 / /8 22 /16 / /8 22 /16 / /8 22 /16 / / s / /1-3D /8 5 1 / / /8 17 / / / / /16 3 / /8 1 3 / / /2-3D / / / /4 8 1 / / / /2 4 3 / /4 / /16 22 / /2-3D /8 4 7 / /2 1 / /16 3 /4 9 1 / / /4 3 / / /16 / / / /1-5D / / / / / / /4 6 3 /16 3 / / / / / /2-5D /8 4 7 / /2 1 / /16 3 /4 9 1 / / /4 3 / / / / / /1-5D /8 5 1 / / /8 17 / / / / /16 3 / /8 1 3 /16 7 / / /2-7.5 d D 8 7 / / / / / / / /8 6 3 /8 6 7 /8 3 / /4 1 1 / / / /2-7.5 t D 8 7 / / / / / / / / /8 3 / /4 1 1 /2 7 / / / /1-7.5D / / / / / / /4 6 3 /16 3 / / /8 / / / /1-7.5 d D /8 5 1 / /16 15 /16 22 / / / / /16 3 / /8 1 3 / / /1-7.5 t D /8 5 1 / /16 15 / / / / / /16 3 / /8 1 3 /16 2 / / /2-10D 8 7 / / / / / / / / /8 3 / /4 1 1 /2 2 3 / / / /1-10D / / / / / /8 3 / / / /16 3 / / /2 2 1 / / /16 Dimensions 2300-D Page 2

7 Blower Designation«A B C D E F G H J K L P Q R S T U V Z* F+K G+K /1-15d D /8 5 3 / / / / /2 7 / /4 7 1 /4 8 9 /16 3 / / / /4 15t D /8 9 3 / / / / /2 7 / /4 8 1 /2 9 1 /16 3 / / /4 / / /4 15d D / / / / / /8 3 / / / /16 3 / / / / /16 15t D / / / / /8 3 / / /2 8 3 /16 3 / / /2 2 5 / / /16 20D /8 9 3 / / / / /2 7 / /4 8 1 /2 9 1 /16 3 / /2 2 1 /4 2 3 / / /4 20D / / / / / / / / / / / / / / / /1-25D /8 9 1 / / / / / / / /8 7 / / /8 3 1 /4 2 1 / / D / / / / / / / / / / / / / / /16 30D / / / / / / / / /8 7 / / /8 3 1 /4 3 3 / / D / / / / / / / / / / / / / 5 16 / / /16 40D / / / / / / / / / / / / / / / /16 50D / / / / / / / / / / / / / / / /2-1.5D 3 67 /8 6 1 / /16 1 / / / / /4 4 5 /16 3 / /4 2D 4 67 /8 6 1 / /16 1 / / / / /4 4 5 /16 3 / /4 3D 4 67 /8 6 1 / /16 1 / / / / /4 4 5 /16 3 / /4 5D / / /8 17 / / / / /16 3 / /2 1 3 / / d D / / /8 17 / / / / /16 3 / /2 1 3 / / t D / / /8 17 / / / / /16 3 / /2 1 3 /16 2 / / /1-10D 8 41 / / / / / /8 3 / / / /16 3 / / /2 2 1 / / /16 10D 8 73 /8 7 3 / / / / /8 3 / / / /16 3 / /8 1 1 /2 2 1 / / /16 15d D /8 7 3 / / / / /8 3 / / / /16 3 / /8 1 1 / / /16 15t D / / / / /8 3 / / /2 8 3 /16 3 / /8 1 1 /2 2 5 / / /16 15d D /8 5 3 / / / / /2 7 / /4 7 1 /4 8 9 /16 3 / / / /4 15t D /8 9 3 / / / / /2 7 / /4 8 1 /2 9 1 /16 3 / / /4 / / / /1-15d D / / / / / /8 3 / / / /16 3 / / / / / /1-15t D / / / / /8 3 / / /2 8 3 /16 3 / / /2 2 / / / /1-20D /8 9 3 / / / / /2 7 / /4 8 1 /2 9 1 /16 3 / /2 2 1 /4 2 3 / / / /1-25D / / / / / / / / / / / / / / / /1-25D / / / / / / / / /8 7 / / /8 3 3 /4 2 1 / / /1-30D / / / / / / / / /8 7 / / /8 3 1 /4 3 3 / / /1-30D / / / / / / / / / / / / /16 / / / /1-40d D / / / / / / / / /8 7 / / / /4 / / /1-40t D / / / / / / / / /8 7 / / /8 3 1 /4 2 3 / / /1-40D / / / / / / / / / / / / / / / / /1-50D / / / / / / / / /8 7 / / /8 3 1 /4 4 1 / / /1-50D / / / / / / / / / / / / / / / /1-60D / / / / / / / / / / / / / / / / /3-1.5D 3 81 / / /8 1 / /4 8 3 / / / /2 3 5 /8 3 / /16 / /8 22 / /3-2D 3 81 / / /8 1 / /4 8 3 / / / /2 3 5 /8 3 / /16 / /8 22 / /2-3D 4 67 /8 6 1 / /16 1 / / / / /4 4 5 /16 3 / / /2-5D / / /8 17 / / / / /16 3 / /2 1 3 / / /2-7.5d D / / /8 17 / / / / /16 3 / /2 1 3 / / /2-7.5t D / / /8 17 / / / / /16 3 / /2 1 3 /16 2 / / /2-10D 8 73 /8 7 3 / / / / /8 3 / / / /16 3 / /8 1 1 /2 2 1 / / / /2-15d D /8 7 3 / / / / /8 3 / / / /16 3 / /8 1 1 / / / /2-15t D / / / / /8 3 / / /2 8 3 /16 3 / /8 1 1 /2 2 5 / / / /1-20D /8 9 3 / / / / /2 7 / /4 8 1 /2 9 1 /16 3 / /4 2 1 /4 2 3 / / / /1-25D / / / / / / / / /8 7 / / /8 3 1 /4 2 1 / / /1-30D / / / / / / / / /8 7 / / /8 3 1 /4 3 3 / / /1-40d D / / / / / / / / /8 7 / / / /4 / / /1-40t D / / / / / / / / /8 7 / / /8 3 1 /4 2 3 / / /1-50D / / / / / / / /8 7 / / / /4 4 1 / / /1-60D / / / / / / / /8 7 / / / /4 5 5 / / /3-3D / / /8 1 / / / / /4 4 5 /16 3 / / /3-5D / / /8 1 / / / / /4 4 5 /16 3 / / /2-7.5D 6 87 / / / / / / /4 6 3 /16 3 / /8 1 3 /8 / / / /2-10D 6 87 / / / / / / /4 6 3 /16 3 / /8 1 3 /8 2 1 / / / /2-15d D / / / / / / /4 6 3 /16 3 / /8 1 3 / / / /2-15t D / / / / / / /2 6 3 /16 3 / /8 1 3 / / / /2-20D 8 91 /8 9 3 / / / /2 7 / /4 8 1 /2 9 1 /16 3 / /4 2 1 /4 2 3 / / / /2-25d D /8 9 3 / / / /2 7 / /4 8 1 /2 9 1 /16 3 / /4 2 1 / / / /2-25t D / / / / / /2 7 / / /2 9 /16 3 / / /4 / / / /2-30D 8 91 / / / / / /2 7 / / /2 9 /16 3 / /4 2 1 / / / /2-40D 8 91 / / / / / /2 7 / / /2 9 /16 3 / /4 2 1 /4 2 1 / / / /2-50D / / / / / / / / /8 7 / / / /4 4 1 / / /2-60D / / / / / / / / /8 7 / / / /4 5 5 / /16 60 «Explanation of designation: /1-.3D means Series 2300, 4 osi pressure, inner housing no. 11, 1 stage, 1 /3 hp motor, direct drive. d With drip-proof motor, if dimensions are different from TEFC. t With TEFC motor, if dimensions are different from drip-proof. * Z = Motor overhang for TEFC motors. There is no overhang for drip-proof motors, except /1-40D and /1-40D which overhang 1 /2". Listed T & U dimensions are for SW inlet. For threaded inlet, T is 5 /16" for inner housing no. 11, 1 /2" for others. If S is greater than 6", threaded inlet is not available. SW discharge (unthreaded pipe) is standard and is included in F. ndischarge C L is 10 9 /16" from farthest base hole, for inner housing no. 11. Female pipe thread is standard. If SW discharge (unthreaded pipe) is specified, add 3 1 /4" to F. I 5 holes when No. 4 discharge is furnished. Number 4 discharge position, straight down, can be furnished on special order, a notch having to be cut out of the base at time of assembly, except for blowers with #11 or #35 cases, no modification is required. Dimensions 2300-D Page 3

8 Dimensions 2300-D Page 2 C L A Discharge Nominal Pipe Size-- female pipe thread for 6" and smaller, unthreaded pipe (SW) for 8" and larger. WARNING: Situations dangerous to personnel and property can develop from incorrect operation of combustion equipment. North American urges compliance with National Safety Standards and Insurance Underwriters recommendations, and care in operation. All dimensions are in inches. Dimensions shown apply only to blowers with T-frame motors. Consult North American Mfg. Co. for dimensions of blowers with other motors. Blower Designation«A B C D E F G H J K L P Q R S T U V Z* F+K G+K /3-15d D / / / / / / /4 6 3 /16 3 / /8 1 1 / / /16 15t D / / / / / / / /2 6 3 /16 3 / /8 1 1 /2 1 5 / / /16 20D / / / / / / / /2 6 3 /16 3 / /8 1 1 / / / /2-30D / / / / / /2 7 / / /2 9 /16 3 / / / / / /2-40d D / / / / / /2 7 / / /2 9 /16 3 / / / / / /2-40t D / / / / / /2 7 / / /2 9 /16 3 / / /4 2 7 / / / /2-50D / / / / / /2 7 / / /2 9 /16 3 / / /4 4 3 / / /4 «Explanation of designation: /1-.3D means Series 2300, 4 osi pressure, inner housing no. 11, 1 stage, 1 /3 hp motor, direct drive. d With drip-proof motor, if dimensions are different from TEFC. t With TEFC motor, if dimensions are different from drip-proof. * Z = Motor overhang for TEFC motors. There is no overhang for drip-proof motors, except /1-40D and /1-40D which overhang 1 /2". Listed T & U dimensions are for SW inlet. For threaded inlet, T is 5 /16" for inner housing no. 11, 1 /2" for others. If S is greater than 6", threaded inlet is not available. SW discharge (unthreaded pipe) is standard and is included in F. ndischarge C L is 10 9 /16" from farthest base hole, for inner housing no. 11. Female pipe thread is standard. If SW discharge (unthreaded pipe) is specified, add 3 1 /4" to F. I 5 holes when No. 4 discharge is furnished. Number 4 discharge position, straight down, can be furnished on special order, a notch having to be cut out of the base at time of assembly, except for blowers with #11 or #35 cases, no modification is required. Printed in USA NA1100-Dims2300-D "SW" means sleeve or weld. A flexible rubberized sleeve (Bulletin 2947) can be slipped over an SW connection and clamped to prevent leaks. A flexible connection does not transmit vibrations or stresses as do welded or threaded connections. Fig. 1. Fig. 2. Fig. 3. Discharge Connections: A threaded (female) flange (Fig. 1) is furnished as standard with blowers of 6" and smaller discharge pipe size. An SW connection (Fig. 2) is standard for 8" and larger, or may be specified (at no extra cost) for smaller sizes (Fig. 3). Inlet Connections: A heavy wire guard (Fig. 1) is standard. An SW inlet (unthreaded, Fig. 2) for sleeve or welding connection may be specified at extra cost. A threaded female inlet may be specified for 3" through 6" inlet at no extra cost (Fig. 3). North American Mfg. Co., 4455 East 71st Street, Cleveland, OH USA, Phone , Facsimile sales@namfg.com l

North American Series 2300 Turbo Blowers 4-44 OSI & 55-11,500 CFM for standardized product 4-60 OSI, up to 100,000 CFM for custom product

North American Series 2300 Turbo Blowers 4-44 OSI & 55-11,500 CFM for standardized product 4-60 OSI, up to 100,000 CFM for custom product Combustion North American Series 2300 Turbo Blowers 4-44 OSI & 55-11,500 CFM for standardized product 4-60 OSI, up to 100,000 CFM for custom product FEATURES Direct drive blowers specifically for combustion

More information

50 HERTZ METRIC BLOWER

50 HERTZ METRIC BLOWER CAPACITIES 50 HERTZ METRIC BLOWER Pressure Range 500mm 20 wc 12 osi 700mm 27 wc 16 osi 900mm 35 wc 20 osi 1100mm 43 wc 24 osi Model Number TBA 500-1.5 TBA 500-2.2 TBA 500-3 TBA 500-4 TBA 500-5.5 TBA 500-

More information

North American 4575 HiRAM

North American 4575 HiRAM Combustion North American 4575 HiRAM The quality and performance of our Tempest, but bigger. Low NOx burner High Velocity - High Turndown Inputs to 4-25 million Btu/hr Direct Spark or Pilot Lighting Furnace

More information

50H Z VERSION. WindJet Air Knife Packages. Deliver superior blowing and drying performance in a complete, customizable package.

50H Z VERSION. WindJet Air Knife Packages. Deliver superior blowing and drying performance in a complete, customizable package. 5H Z VERSION Experts in Spray Technology Spray Nozzles Spray Control Spray Analysis Spray Fabrication WindJet Air Knife Packages Deliver superior blowing and drying performance in a complete, customizable

More information

TURBO PRESSURE BLOWERS

TURBO PRESSURE BLOWERS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS TURBO PRESSURE BLOWERS TBA TBR CATALOG 10 APRIL 13 TURBO PRESSURE BLOWERS Models TBA TBR TBR Arrangement 8 Model TBA and TBR fans from

More information

ECLIPSE TURBO BLOWERS SERIES SMJ

ECLIPSE TURBO BLOWERS SERIES SMJ Bulletin /9 ECLIPSE TURBO BLOWERS SERIES SMJ High efficiency Heavy gauge steel base and housing Aluminum impellers balanced statically and dynamically Matching air filters available Changeable outlet positions

More information

ECLIPSE TURBO BLOWERS SERIES SMJ

ECLIPSE TURBO BLOWERS SERIES SMJ Bulletin /0 ECLIPSE TURBO BLOWERS SERIES SMJ High efficiency Heavy gauge steel base and housing Aluminum impellers balanced statically and dynamically Matching air fi lters available Changeable outlet

More information

Defining Innovation. turbo pressure blowers. Twin City Catalog 1200

Defining Innovation. turbo pressure blowers. Twin City Catalog 1200 Defining Innovation. turbo pressure blowers MODEL TBA TBR 1 Twin City Catalog CATALOG -A May 11 Model TBA/TBR Turbo Pressure Blowers Model TBA and TBR fans from Twin City Fan & Blower are constant pressure,

More information

Contents. Identification

Contents. Identification Contents Identification Type key Product data Introduction Applications Features and benefits Performance range pole pole Construction Sectional drawing Construction features Test pressure Operating conditions

More information

Bulletin BCF 103 DESIGN 10A BACKWARD INCLINED WHEELS

Bulletin BCF 103 DESIGN 10A BACKWARD INCLINED WHEELS Bulletin BCF 10 DESIGN 10A BACKWARD INCLINED WHEELS Proven Reliability in Industrial Environments and Corrosive Atmospheres Design 10A s with Backward Inclined Wheels Chicago s Design 10A is a rugged multi-purpose

More information

Model 133 Models 134 & 135 AURORA 130 SERIES SINGLE STAGE TURBINE TYPE PUMPS

Model 133 Models 134 & 135 AURORA 130 SERIES SINGLE STAGE TURBINE TYPE PUMPS Model Models 4 & AURORA 0 SERIES SINGLE STAGE TURBINE TYPE PUMPS WWW.AURORAPUMP.COM AURORA 0 SERIES Single Stage Turbine Type Pumps Capacities to 0 G.P.M. Heads to 700 Ft. Temperatures to F A Pioneer in

More information

Bulletin ACF 103 AIRFOIL CENTRIFUGAL FANS DESIGN 10A

Bulletin ACF 103 AIRFOIL CENTRIFUGAL FANS DESIGN 10A Bulletin ACF 103 AIRFOIL CENTRIFUGAL FANS DESIGN 10A Quieter, More Efficient Airfoil Fans for Commercial and Light Industrial Applications Design 10A Fans with Airfoil Wheels Fourteen Sizes to 80" Volumes

More information

Vaneaxial Fans. Series 25 Series 53 Series 53C Series 54 Series 55 HARTZELL. Hartzell Fan, Inc., Piqua, Ohio

Vaneaxial Fans. Series 25 Series 53 Series 53C Series 54 Series 55 HARTZELL. Hartzell Fan, Inc., Piqua, Ohio Vaneaxial Fans Series 25 Series 53 Series 53C Series 54 Series 55 BUILT WITH HONOR HARTZELL FAN, INC PIQUA, OHIO USA HARTZELL Hartzell Fan, Inc., Piqua, Ohio 45356 February 2008 Index Model Code Explanation...Page

More information

North American Y-Type Strainers for Gas, Oil, Oxygen, Steam

North American Y-Type Strainers for Gas, Oil, Oxygen, Steam Combustion North American Y-Type s for Gas, Oil, Oxygen, Steam The new 8555Y line provides many unique features: High pressure and temperature designs for rugged industrial applications Body and screen

More information

SQAF AIRFOIL BLOWERS CLASS IP CLASS II CLASS IIP CLASS III. OEM and Industrial Air Handling Specialist

SQAF AIRFOIL BLOWERS CLASS IP CLASS II CLASS IIP CLASS III. OEM and Industrial Air Handling Specialist OEM and Industrial Air Handling Specialist SQAF AIRFOIL BLOWERS CLASS IP CLASS II CLASS IIP CLASS III 69 Snider Road, Mason, OH 4040-913 Telephone: 13-3-0600 Visit us at www.cincinnatifan.com for more

More information

.3 Section Vibration Isolation and Seismic Control..2 ANSI/AMCA 210/ASHRAE 51 Laboratory Methods of Testing Fans for Rating.

.3 Section Vibration Isolation and Seismic Control..2 ANSI/AMCA 210/ASHRAE 51 Laboratory Methods of Testing Fans for Rating. Issued 2005/06/01 Section 15831 Commercial Fans Page 1 of 6 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01355 Waste Management and Disposal..2 Section 15053 Motors, Drives and Guards..3 Section 15072

More information

Waterfall Pumps Manufacturing

Waterfall Pumps Manufacturing Waterfall Pumps Manufacturing Our Vision for the future to become the world s premier provider of fire protection pumps. Our ongoing mission is to be the customers first choice, a trusted provider and

More information

CENTAXIAL TUBULAR CENTRIFUGAL FANS. BIA Airfoil Blade Design Direct Drive & Belt Driven Model CBD / CDD (Class I, II & III) Model CBD Belt Driven

CENTAXIAL TUBULAR CENTRIFUGAL FANS. BIA Airfoil Blade Design Direct Drive & Belt Driven Model CBD / CDD (Class I, II & III) Model CBD Belt Driven Model CBD Belt Driven Model CDD Direct Drive CENTAXIAL TUBULAR CENTRIFUGAL FANS BIA Airfoil Blade Design Direct Drive & Belt Driven Model CBD / CDD (Class I, II & III) CATALOG 337 February 2004 Centaxial

More information

Regenerative Turbine Pumps

Regenerative Turbine Pumps Bulletin E4 November 009 E4 T4 Series Regenerative Turbine Pumps Capacities to GPM Heads to 600 Feet Temperatures to 00 F MTH PUMPS MTH E4 T4 Series Close-coupled and pedestal mounted regenerative turbine

More information

DESIGN GUIDELINES FANS PAGE 1 of 7

DESIGN GUIDELINES FANS PAGE 1 of 7 DESIGN GUIDELINES FANS PAGE 1 of 7 1.1. REFERENCE STANDARDS 1.1.1. Publications listed below (including amendments, addenda, revisions, supplements and errata) form a part of this specification to the

More information

OEM and Industrial Air Handling Specialist Snider Road, Mason, OH Telephone:

OEM and Industrial Air Handling Specialist Snider Road, Mason, OH Telephone: HDBI BLOWERS OEM and Industrial Air Handling Specialist BACKWARD INCLINED CLASS II CLASS III CLASS IV 797 Snider Road, Mason, OH 45040-915 Telephone: 51-57-000 Visit us at www.cincinnatifan.com for more

More information

VANEAXIAL & TUBEAXIAL FANS

VANEAXIAL & TUBEAXIAL FANS BULLETIN 482 July 2008 VANEAXIAL & TUBEAXIAL FANS Type "S" Belt Driven Featuring Welded Steel Propellers Models VSBD & TSBD Model TSBD Belt Driven Tubeaxial Type "S" Vaneaxial & Tubeaxial Fans For applications

More information

FIXED PITCH PROPELLER FANS

FIXED PITCH PROPELLER FANS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS FIXED PITCH PROPELLER FANS MODEL TCWP CATALOG AX500 DECEMBER 2012 PROPELLER FANS Model TCWP Fixed Pitch Heavy-Duty Construction Twin

More information

Adjustable Port Valves for HOT or COLD AIR, GAS, OIL, WATER, STEAM

Adjustable Port Valves for HOT or COLD AIR, GAS, OIL, WATER, STEAM ADJUSTABLE PORT VALVES Bulletin 1008A December 2009 Adjustable Port Valves for HOT or COLD AIR, GAS, OIL, WATER, STEAM 3" Adjustable Port Gas Valve Beck Electric Operator 6" Adjustable Port Air Valve Honeywell

More information

3312 Model. pumping Model Model AURORA Series HORIZONTAL AND VERTICAL CLOSE-COUPLED PUMPS

3312 Model. pumping Model Model AURORA Series HORIZONTAL AND VERTICAL CLOSE-COUPLED PUMPS 3312 Model pumping 3314 Model 3311 Model AURORA 3310 Series HORIZONTAL AND VERTICAL CLOSE-COUPLED PUMPS WWW.AURORAPUMP.COM AURORA 3310 Series Horizontal and Vertical Close-Coupled Pumps Capacities to 3800

More information

Twin City Fan & Blower

Twin City Fan & Blower Twin City Fan & Blower BULLETIN AX510-A October 2009 ADJUSTABLE PITCH PROPELLER FANS TYPE TCWPX TCWPX Adjustable Pitch Propeller Fans Sizes 24" 48" Direct Drive Belt Driven Heavy-Duty Construction Twin

More information

North American Automatic Manual Reset and Motorized Valves

North American Automatic Manual Reset and Motorized Valves Combustion North American Automatic Manual Reset and Motorized Valves 1516 Manual Reset 1517 Motorized 1516/1517 Automatic Oil Shutoff Valves Agency approvals: UL, FM, CSA Proof-of-Closure Switch High

More information

Turbo Pressure Blowers

Turbo Pressure Blowers www.americanfan.com Bulletin VP4 Turbo Pressure Blowers Howden Industrial Fan Group American Fan / Joy Fan / Garden City Fan Features Heavy gauge continuously welded housings, reversible and rotatable

More information

3340 Series Single Stage End Suction Pumps

3340 Series Single Stage End Suction Pumps 3340 Series Single Stage End Suction Pumps Bulletin 3340/Rev. A Model 3344 Aurora 3340 Pump Setting New Standards of Efficiency Liquid handling requirements are much more involved than they were five years

More information

BULLETIN 456. July 1997 VANEAXIAL FANS. Type W Direct Drive/Belt Driven. Model VW Direct Drive. Model VWBD Belt Driven

BULLETIN 456. July 1997 VANEAXIAL FANS. Type W Direct Drive/Belt Driven. Model VW Direct Drive. Model VWBD Belt Driven BULLETIN 456 July 1997 VANEAXIAL FANS Type W Direct Drive/Belt Driven Model VW Direct Drive Model VWBD Belt Driven Aerovent certifies that the Type W Vaneaxial Fans shown herein are licensed to bear the

More information

Complete HVAC Capability

Complete HVAC Capability Air Handling Units Brochure 1110 January 2006 Complete HVAC Capability MEA Horizontal Draw-Thru to Size 65 Vertical Draw-Thru to Size 50 1000 to 60,000 CFM Forward Curved or Airfoil Wheels Inlet Vane Option

More information

an ISO 9001 Company Bulletin BCPF 100 NEW Design 70 PLUG FANS CHICAGO BLOWER CORPORATION GLENDALE HEIGHTS, ILLINOIS USA

an ISO 9001 Company Bulletin BCPF 100 NEW Design 70 PLUG FANS CHICAGO BLOWER CORPORATION GLENDALE HEIGHTS, ILLINOIS USA an ISO 9001 Company Bulletin BCPF 100 NEW Design 70 PLUG FANS New Energy Saving Wheel Mounted Motors to 125 HP Pre-Engineered Sizes to 60" Capacities to 156,000 CFM CHICAGO BLOWER CORPORATION GLENDALE

More information

FIRE PUMPS F AI LISTED R LISTED N K S MOR S E P U IT Y S Y S T E M CE R T IF IE D

FIRE PUMPS F AI LISTED R LISTED N K S MOR S E P U IT Y S Y S T E M CE R T IF IE D IS O 9 0 0 1 IT Y S Y S T E M R LISTED RBA N K S MOR S E P U MP C F AI LISTED UAL T IF IE D R CE R Q FIRE PUMPS HORIZONTAL SPLIT CASE FIRE PUMP SYSTEM DIESEL ENGINE DRIVEN 1 4 5 2 3 6 7 8 1. Fuel Tank,

More information

Centrifugal Utility Fans - SFD/SFB

Centrifugal Utility Fans - SFD/SFB C H F D B G E A Centrifugal Utility Fans - SFD/SFB SFB STANDARD CONSTRUCTION FEATURES HOUSING: Heavy gauge steel housing with Lock-seam construction Unit support angles with prepunched mounting holes Adjustable

More information

The Industrial Choice. Vane Section For Model VTBD. Model TTABD TUBEAXIAL & VANEAXIAL FANS. Type "T" Belt Driven Model TTABD / VTBD

The Industrial Choice. Vane Section For Model VTBD. Model TTABD TUBEAXIAL & VANEAXIAL FANS. Type T Belt Driven Model TTABD / VTBD The Industrial Choice. Vane Section For Model VTBD Model TTABD TUBEAXIAL & VANEAXIAL S Type "T" Belt Driven Model TTABD / VTBD BULLETIN 424-A November 1998 Model TTABD/VTBD Tubeaxial/Vaneaxial Fans Aerovent

More information

FRP Fans: CLUB Series Performance and Technical Information

FRP Fans: CLUB Series Performance and Technical Information FRP Fans: CLUB Series 1500-7300 Performance and Technical Information Verantis Environmental Solutions Group provides solutions for most common and complex situations including repair, rebuilding, field

More information

High Temperature Chemical Process Inline Pumps

High Temperature Chemical Process Inline Pumps Bulletin C-1.2.21. Dean Pump Division High Temperature Chemical Process Inline Pumps Series DL Series DL High Temperature Chemical Process Inline Pumps Capacities to 6 GPM (182 m 3 /hr) Heads to feet (167

More information

Regenerative Turbine Pumps

Regenerative Turbine Pumps Bulletin E4 July E4/T4 Series Regenerative Turbine Pumps Capacities to GPM Heads to 6 Feet Temperatures to F MTH E4/T4 Series Close-coupled and pedestal mounted regenerative turbine pumps represent the

More information

Defining Innovation. backward curved FANs

Defining Innovation. backward curved FANs Defining Innovation. high efficiency industrial backward curved FANs TYPE HIB BULLETIN 00-B May 20 HIB High-Efficiency Industrial Backward-Curved Fans Model HIB fans from Twin City Fan & Blower employ

More information

EXHAUST FANS CUD & CUB UPBLAST FANS

EXHAUST FANS CUD & CUB UPBLAST FANS EXHAUST FANS CUD & CUB UPBLAST FANS Suitable for roof or wall mount Backward inclined, non overloading wheels Spun aluminum housing Blades & inlets fabricated from aluminum Easy access to motor compartment

More information

Tubular Centrifugal Inline Fans Page Introduction... 2 Construction Features... 3 Specification and Dimension Data TCN-D (Inline Fan- Direct

Tubular Centrifugal Inline Fans Page Introduction... 2 Construction Features... 3 Specification and Dimension Data TCN-D (Inline Fan- Direct Tubular Centrifugal Inline Fans Page Introduction........................................... 2 Construction Features.................................. 3 Specification and Dimension Data TCN-D (Inline Fan-

More information

SQBI BLOWERS BACKWARD INCLINED CLASS II CLASS IIP CLASS III. OEM and Industrial Air Handling Specialist

SQBI BLOWERS BACKWARD INCLINED CLASS II CLASS IIP CLASS III. OEM and Industrial Air Handling Specialist OEM and Industrial Air Handling Specialist SQBI BLOWERS BACKWARD INCLINED CLASS II CLASS IIP CLASS III 7697 Snider Road, Mason, OH 4040-913 Telephone: 13-73-0600 Visit us at www.cincinnatifan.com for more

More information

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm Product Data 42BH System Fan Coil 800 to 4000 Cfm Satisfy All Your Design Requirements with Carrier s Versatile 42BH Fan Coil Unit A selection of 6 sizes covers capacities from 800 to 4000 cfm Choice of

More information

DPS. The SSV Dual Pump System

DPS. The SSV Dual Pump System DPS The SSV Dual Pump System A Full Range of Product Features The DPS series of 36L stainless steel vertical multi-stage pumps from G&L has been designed to provide reliable high pressure boosting to serve

More information

Filtered Kitchen Supply Packaged Ventilator

Filtered Kitchen Supply Packaged Ventilator Filtered Kitchen Supply Packaged Ventilator Page Introduction........................................... 2 Information............................................ 3 Specifications and Dimension Data KD................................................

More information

SECTION AXIAL HVAC FANS

SECTION AXIAL HVAC FANS SECTION 233413 - AXIAL HVAC FANS 1. PART 1 GENERAL 1.1. RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

The Industrial Choice. Model VB Direct Drive. Model VBBD Belt Driven VANEAXIAL FANS. Direct Drive & Belt Driven Model VB / VBBD

The Industrial Choice. Model VB Direct Drive. Model VBBD Belt Driven VANEAXIAL FANS. Direct Drive & Belt Driven Model VB / VBBD The Industrial Choice. Model VB Direct Drive Model VBBD Belt Driven VANEAXIAL FANS Direct Drive & Belt Driven Model VB / VBBD BULLETIN 466 November 2000 Contents Construction Features Belt Driven... 3

More information

Inline and Roof Mounted Fans

Inline and Roof Mounted Fans CV Inline and Roof Mounted Fans Page Introduction........................................... 2 Construction Features................................. 3-4 Specifications and Dimension Data CVD (Direct Drive

More information

M50 L50 Series Multistage Regenerative Turbine Pumps

M50 L50 Series Multistage Regenerative Turbine Pumps Page M- MTH PUMPS M L Series Multistage Regenerative Turbine Pumps Capacities to 4 GPM Heads to Feet Single or Multi-stage Units (up to stages) Vertical Close Coupled Horizontal Close Coupled Horizontal

More information

Square Inline Fans with Multi-Directional Discharge

Square Inline Fans with Multi-Directional Discharge SQN Square Inline Fans with Multi-Directional Discharge Page Introduction............................................2 Standard Construction Features............................ 3 Specifications and Dimension

More information

VERANTIS. FRP Fans: CMHB Series Performance and Technical Information. Environmental Solutions Group

VERANTIS. FRP Fans: CMHB Series Performance and Technical Information. Environmental Solutions Group VERANTIS Environmental Solutions Group FRP Fans: CMHB Series 6-8-10 Performance and Technical Information Bulletin 11-6 Rev May 2013 VERANTIS Environmental Solutions Group Verantis Environmental Solutions

More information

Sealless Magnetic Coupled Hot Oil Circulation Pumps acc. to DIN EN / ISO 2858 Type NMWR / NMWB / NMW. our. contribution for

Sealless Magnetic Coupled Hot Oil Circulation Pumps acc. to DIN EN / ISO 2858 Type NMWR / NMWB / NMW. our. contribution for Sealless Magnetic Coupled Hot Oil Circulation Pumps acc. to DIN EN 22858 / ISO 2858 Type NMWR / NMWB / NMW our contribution for environmental protection General DICKOW pumps of series NMWR / NMWB / NMW

More information

Design and Application Details

Design and Application Details Model 400 OVENPAK Gas Page 2105 Design and Application Details OVENPAK s are nozzle-mixing gas burners for many industrial direct-fired applications where clean combustion and high turndown are required.

More information

3800 Series. Single Stage End Suction Pumps. Capacities to 4200 G.P.M. (954 m 3 /hr) Heads to 520 Feet (180 Meters) Temperatures to 300 F (149 C)

3800 Series. Single Stage End Suction Pumps. Capacities to 4200 G.P.M. (954 m 3 /hr) Heads to 520 Feet (180 Meters) Temperatures to 300 F (149 C) 3800 Series Single Stage End Suction Pumps Capacities to 200 G.P.M. (95 m 3 /hr) Heads to 520 Feet (180 Meters) Temperatures to 300 F (19 C) MODEL 380 Aurora 3800 Pump Setting New Standards of Efficiency

More information

VANEAXIAL FANS. DUCT FANS Capacities to 60,000 CFM Static pressures to 2 WG. TUBEAXIAL FANS Capacities to 86,000 CFM Static pressures to 3 WG

VANEAXIAL FANS. DUCT FANS Capacities to 60,000 CFM Static pressures to 2 WG. TUBEAXIAL FANS Capacities to 86,000 CFM Static pressures to 3 WG BULLETIN 671 AUGUST, 2016 VANEAXIAL FANS DUCT FANS Capacities to 60,000 Static pressures to 2 WG TUBEAXIAL FANS Capacities to 86,000 Static pressures to 3 WG Capacities to 0,000 Static pressures to 5 WG

More information

PennBarry Fan Guide Specification. Laboratory Exhaust System: Model vplume

PennBarry Fan Guide Specification. Laboratory Exhaust System: Model vplume PennBarry Fan Guide Specification Laboratory Exhaust System: Model vplume This document 2018 PennBarry vplume is a commercial lab exhaust fan that ensures a greater margin of safety by effectively dispersing

More information

Twin City Fan & Blower

Twin City Fan & Blower Twin City Fan & Blower BULLETIN 4810 August 2005 PROPELLER WALL S DIRECT AND BELT DRIVE TYPE WPMD/WPMB WPMD/WPMB Propeller Wall Fans Twin City Fan & Blower WPMD and WPMB Medium Duty Propeller Wall Fans

More information

North American Miscellaneous Connectors

North American Miscellaneous Connectors Combustion North American Miscellaneous Connectors 8775 Quick Disconnects for Oil, Compressed Air, and Natural Gas Bulletin 8770 FEATURES The 8775 couplings allow you to couple and uncouple your hoses

More information

Tubular Centrifugal Fans

Tubular Centrifugal Fans Tubular Centrifugal Fans Model TCB Inline - Horizontal or Vertical Roof Upblast and Roof Supply March 2007 Tubular Centrifugal Fans The TCB series of inline centrifugal fans is designed for ducted inline,

More information

900 Series Split Case Fire Pump Systems

900 Series Split Case Fire Pump Systems BULLETIN 900/REV. E 900 Series Split Case Fire Pump Systems MODEL 481 MODEL 483 FM Approved U L Listed motralec 4 rue Lavoisier. ZA Lavoisier. 95223 HERBLAY CEDEX Tel. : 01.39.97.65.10 / Fax. : 01.39.97.68.48

More information

WELDING FUME EXHAUSTERS & ARMS

WELDING FUME EXHAUSTERS & ARMS WELDING FUME EXHAUSTERS & ARMS The Ace 75 Series is our flexible and effective line of welding fume exhausters and extraction arms for shops that elect to exhaust their weld fumes outdoors instead of through

More information

SECTION CENTRIFUGAL HVAC FANS

SECTION CENTRIFUGAL HVAC FANS SECTION 233416 - CENTRIFUGAL HVAC FANS 1. PART 1 GENERAL 1.1. RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Twin City Fan & Blower

Twin City Fan & Blower Twin City Fan & Blower BULLETIN AX100-A October 2008 AXIFAN VANEAXIAL FANS TYPE TCVA TCVA Vaneaxial Fans The heart of the TCVA AXIFAN fan lies in its wheel. Cast of high strength aluminum alloy, the one-piece

More information

EZ SERIES BOOSTER PUMPS

EZ SERIES BOOSTER PUMPS EZ SERIES BOOSTER PUMPS Cast Iron And Stainless Steel Booster Pumps Webtrol has been building Booster Pumps for over 4 years for various industrial, commercial and agricultural uses and has long been a

More information

Tube Axial Fan Page Specifications & Dimension Data Performance Data

Tube Axial Fan Page Specifications & Dimension Data Performance Data Tube Axial Fan Page Introduction........................................... 2 Construction Features................................... 3 Information........................................... 4 Specifications

More information

Air Handling Unit Fan Selection Guide

Air Handling Unit Fan Selection Guide KEES Air Handling Unit Fan Selection Guide This document applies to models: DFG Direct Fired Gas Heater IFG Indirect Fired Gas Heater MUA Tempered Air NTS Non-Tempered Supply Table of Contents: Page 2-4

More information

North American 1599 Electro-Hydraulic Gas Shutoff Valve Bulletin 1599

North American 1599 Electro-Hydraulic Gas Shutoff Valve Bulletin 1599 Combustion North American 1599 Electro-Hydraulic Gas Shutoff Valve 1599 valves are normally closed safety shutoff valves which are controlled by an electro-hydraulic actuator. 1599 s can be ordered as

More information

EZ SERIES BOOSTER PUMPS

EZ SERIES BOOSTER PUMPS EZ SERIES BOOSTER PUMPS Cast Iron And Stainless Steel Booster Pumps Webtrol has been building Booster Pumps for over 4 years for various industrial, commercial and agricultural uses and has long been a

More information

The Industrial Choice. Model SCDD Direct Drive. Model SCBD Belt Driven SQUARE INLINE FANS. Direct Drive & Belt Driven Model SCDD / SCBD

The Industrial Choice. Model SCDD Direct Drive. Model SCBD Belt Driven SQUARE INLINE FANS. Direct Drive & Belt Driven Model SCDD / SCBD The Industrial Choice. Model SCDD Direct Drive Model SCBD Belt Driven SQUARE INLINE FANS Direct Drive & Belt Driven Model SCDD / SCBD BULLETIN 40 January 007 Square Inline Centrifugal Fans General Information

More information

EZ SERIES BOOSTER PUMPS

EZ SERIES BOOSTER PUMPS EZ SERIES BOOSTER PUMPS Cast Iron And Stainless Steel Booster Pumps Webtrol has been building Booster Pumps for over 4 years for various industrial, commercial and agricultural uses and has long been a

More information

EZ SERIES BOOSTER PUMPS

EZ SERIES BOOSTER PUMPS EZ SERIES BOOSTER PUMPS Cast Iron And Stainless Steel Booster Pumps Webtrol has been building Booster Pumps for over years for various industrial, commercial and agricultural uses and has long been a leader

More information

EZ SERIES BOOSTER PUMPS

EZ SERIES BOOSTER PUMPS EZ SERIES BOOSTER PUMPS Cast Iron And Stainless Steel Booster Pumps Webtrol has been building Booster Pumps for over 4 years for various industrial, commercial and agricultural uses and has long been a

More information

User s Manual D-Series Blowers and Exhausters

User s Manual D-Series Blowers and Exhausters User s Manual D-Series Blowers and Exhausters D05-1 ½ HP TEFC 115/230 VOLTS, 1 PH D05-3 ½ HP TEFC 208/230/460 VOLTS, 3 PH D10-1 1 HP TEFC 115/230 VOLTS, 1 PH D10-3 1 HP TEFC 208/230/460 VOLTS, 3 PH D15-1

More information

FILTERED AIR SUPPLY FANS

FILTERED AIR SUPPLY FANS BULLETIN 664-B September 2004 FILTERED AIR SUPPLY FANS Wall Mounted Roof Mounted Catalog Numbering System To identify a specific fan for ordering or engineering specification, it is necessary to show

More information

INDUSTRIES AMERICAN COOLAIR CORPORATION. Centrifugal Filtered Supply Roof Ventilators TYPE CFS - TYPE SIS

INDUSTRIES AMERICAN COOLAIR CORPORATION. Centrifugal Filtered Supply Roof Ventilators TYPE CFS - TYPE SIS INDUSTRIES AMERICAN COOLAIR CORPORATION Centrifugal Filtered Supply Roof Ventilators TYPE CFS - TYPE SIS CFS Centrifugal Filtered Supply Fans Applications The CFS Centrifugal Filtered supply fans with

More information

Fixed Pitch Vane Axial Fan

Fixed Pitch Vane Axial Fan Fixed Pitch Vane Axial Fan Page Introduction...........................................2 Construction Features...................................3 Mounting Options.......................................3

More information

H.S. MACHINERY RING COMPRESSORS

H.S. MACHINERY RING COMPRESSORS OPERATION & PARTS MANUAL Thank you for purchasing an H.S Machinery Limited Regenerative Blower. This product is manufactured under strict ISO-9001-2000 quality control guidelines to ensure your satisfaction.

More information

The Industrial Choice. Model BD40C UPBLAST AXIAL ROOF VENTILATORS. Macheta Airfoil Design. Model BD40C

The Industrial Choice. Model BD40C UPBLAST AXIAL ROOF VENTILATORS. Macheta Airfoil Design. Model BD40C The Industrial Choice. Model BD40C UPBLAST AXIAL ROOF VENTILATORS Macheta Airfoil Design Model BD40C BULLETIN 616 July 1997 Upblast Axial Model BD40C Roof Ventilators The Model BD40C is the most versatile

More information

SUGGESTED SPECIFICATIONS Pump Frames NS3 thru OMC5

SUGGESTED SPECIFICATIONS Pump Frames NS3 thru OMC5 SOLIDS-HANDLING WASTEWATER PUMPS Pump Frames NS3 thru OMC5 GENERAL Furnish and install Vertical Closed-Shaft Wet-Pit Pumping Units complete with all accessories and appurtenances as shown in the plans

More information

Good Enough Never Is. Plug Fan SERIES 12

Good Enough Never Is. Plug Fan SERIES 12 Plug Fan SERIES 12 Good Enough Never Is The Hartzell Difference Combine Hartzell QUALITY with your PRODUCT for a BETTER CHOICE for your customers! GOOD ENOUGH NEVER IS. Hartzell Air Movement is the industrial

More information

EXPANSION JOINT SELECTION GUIDE

EXPANSION JOINT SELECTION GUIDE EXPANSION JOINT SELECTION GUIDE The proper selection and application of an expansion joint is the determining factor in its operation and life. Improper selection and application will lead to problems

More information

EZ SERIES BOOSTER PUMPS

EZ SERIES BOOSTER PUMPS EZ SERIES BOOSTER PUMPS Cast Iron And Stainless Steel Booster Pumps Webtrol has been building Booster Pumps for over years for various industrial, commercial and agricultural uses and has long been a leader

More information

Regenerative Turbine Pumps

Regenerative Turbine Pumps Bulletin 0 0 2 0 2 170 270 Series Regenerative Turbine Pumps Capacities to 0 GPM Heads to Feet MTH PUMPS 0 2 0 2 170 270 Series Regenerative Turbine Pump MTH 0 2 0 2 170 270 Series regenerative turbine

More information

Fiberglass Axial Flow Fans. Series 28 Series 28B. Series 34 Series 35 Series 35V. Series 29 Series 29B HARTZELL

Fiberglass Axial Flow Fans. Series 28 Series 28B. Series 34 Series 35 Series 35V. Series 29 Series 29B HARTZELL Fiberglass Axial Flow Fans Series 28 Series 28B Series 29 Series 29B Series 34 Series Series V BUILT WITH HONOR HARTZELL FAN, INC PIQUA, OHIO USA HARTZELL Hartzell Fan, Inc., Piqua, Ohio 46 Bulletin A-39-N

More information

Regenerative Turbine Pumps

Regenerative Turbine Pumps Bulletin T June 04 T E Series Regenerative Turbine Pumps Capacities to 40 GPM Heads to 700 Feet Temperatures to 00 F MTH PUMPS MTH T E Series Close-coupled and pedestal mounted regenerative turbine pumps

More information

Series 8500 Centrifugal Swingout Fans Design 8510 Centrifugal Airfoil Design 8520 Centrifugal BI

Series 8500 Centrifugal Swingout Fans Design 8510 Centrifugal Airfoil Design 8520 Centrifugal BI Bulletin 8510-4 May 2000 Series 8500 Centrifugal Swingout Fans Design 8510 Centrifugal Airfoil Design 8520 Centrifugal BI Description Index Series 8500 Centrifugal Swingout Fans The Series 8500 Centrifugal

More information

Product Numbering System Typical Specifi cations, Models 4AC, 4AE, 6AC, 6AE, 8AC Pump Assembly, Types AC & AE

Product Numbering System Typical Specifi cations, Models 4AC, 4AE, 6AC, 6AE, 8AC Pump Assembly, Types AC & AE Index Sheet ITEM S Bulletin Product Numbering System... 1 Typical Specifi cations, Models 4AC, 4AE, 6AC, 6AE, 8AC... 2 Pump Assembly, Types AC & AE... 3-4 Dimensions, Types AC & AE... 5-8 Selection Curves,

More information

RM-1200 Slim Round Control Damper

RM-1200 Slim Round Control Damper RM-1200 Slim Round Control Damper Product Bulletin Code No. LIT-12011358 Issued June 16, 2008 Since 1905, Johnson Controls has developed and refined air control products by providing the highest quality

More information

AXIFAN VANEAXIAL FANS

AXIFAN VANEAXIAL FANS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS AXIFAN VANEAXIAL FANS MODEL TCVA CATALOG AX100 JUNE 2013 VANEAXIAL FANS Model TCVA The heart of the TCVA AXIFAN fan lies in its wheel.

More information

General TAHVIEH HAMOON Airfoil Centrifugal Fans Utilize the latest design techniques to product a quiet highly efficient air mover.

General TAHVIEH HAMOON Airfoil Centrifugal Fans Utilize the latest design techniques to product a quiet highly efficient air mover. General TAHVIEH HAMOON Airfoil Centrifugal Fans Utilize the latest design techniques to product a quiet highly efficient air mover. Aerodynamically designed blades and air passages allow more air to be

More information

SD-1250 and SD-1600 Series Smoke Dampers

SD-1250 and SD-1600 Series Smoke Dampers SD-1250 and SD-1600 Series Smoke Dampers Product Bulletin Code No. LIT-1201592 Issued January 30, 2014 Supersedes October 14, 2013 Johnson Controls provides a leakage-rated damper for life safety smoke

More information

SQUARE INLINE CENTRIFUGAL FANS

SQUARE INLINE CENTRIFUGAL FANS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS SQUARE INLINE CENTRIFUGAL FANS DSI BSI CATALOG 40 FEBRUARY 07 SQUARE INLINE CENTRIFUGAL FANS Overview DSI BSI Twin City Fan & Blower

More information

EZ SERIES BOOSTER PUMPS

EZ SERIES BOOSTER PUMPS EZ SERIES BOOSTER PUMPS Cast Iron And Stainless Steel Booster Pumps Webtrol has been building Booster Pumps for over years for various industrial, commercial and agricultural uses and has long been a leader

More information

Centrifugal Filtered Supply Roof Blowers

Centrifugal Filtered Supply Roof Blowers CFS Centrifugal Filtered Supply Roof Blowers Page Introduction...................................... 2 Specifications and Dimension Data................... 3 Typical Installation................................

More information

BULLETIN 912-A. February 1999 HIGH PRESSURE BLOWER. Model HPB Direct Drive/Belt Driven

BULLETIN 912-A. February 1999 HIGH PRESSURE BLOWER. Model HPB Direct Drive/Belt Driven BULLETIN 912-A February 1999 HIGH PRESSURE BLOWER Model HPB Direct Drive/Belt Driven Model HPB High Pressure Blowers Aerovent s High Pressure Blowers feature high static pressure capabilities from 11"

More information

100% OUTSIDE AIR MAKE-UP UNITS WITH DISCHARGE TEMPERATURE CONTROL & c.pco DIRECT DIGITAL CONTROL MODULE

100% OUTSIDE AIR MAKE-UP UNITS WITH DISCHARGE TEMPERATURE CONTROL & c.pco DIRECT DIGITAL CONTROL MODULE 100% OUTSIDE AIR MAKE-UP UNITS WITH DISCHARGE TEMPERATURE CONTROL & c.pco DIRECT DIGITAL CONTROL MODULE Start-up must be performed by a trained, experienced service person. The following general start-up

More information

Twin City Fan & Blower

Twin City Fan & Blower BULLETIN 600 Twin City Fan & Blower September 2009 VENTILATING SETS TYPE BCV (Backward Inclined) TYPE BCVU5 (UL 705 Listed) TYPE BCVU2 (UL 762 Listed) TYPE BCVSH (UL Smoke & Heat) TYPE BAV (Airfoil) TYPE

More information

CAST ALUMINUM PRESSURE BLOWERS

CAST ALUMINUM PRESSURE BLOWERS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS CAST ALUMINUM PRESSURE BLOWERS TPD TPB CATALOG 820 JANUARY 2013 PRESSURE BLOWERS Models TPD TPB Twin City Fan & Blower s Cast Aluminum

More information

Application & Reference Data Typical Specifications. Section 914 Vertical Turbine Fire Pump

Application & Reference Data Typical Specifications. Section 914 Vertical Turbine Fire Pump Section 914 Page 101 Supersedes Section 913 Page 101 Dated November 1, 199p Application & Reference Data Typical Specifications Section 914 Section 914 Page 102 Supersedes Section 913 Page 102 Dated November

More information

MARINE DUTY TUBEAXIAL & VANEAXIAL FANS

MARINE DUTY TUBEAXIAL & VANEAXIAL FANS BULLETIN 420 November 2000 MARINE DUTY TUBEAXIAL & VANEAXIAL FANS Type MD Direct Drive Model MDTM, MDVM & MDVH Marine Duty Tubeaxial and Vaneaxial Fans Aerovent s Marine Duty Fans feature medium and high

More information