Table of Contents. Diffusers DIFFUSER PLENUM (OPTIONAL) CONTROL UNIT

Size: px
Start display at page:

Download "Table of Contents. Diffusers DIFFUSER PLENUM (OPTIONAL) CONTROL UNIT"

Transcription

1 Diffusers Table of Contents Introduction In today s diverse building environment, we are seeing an expanding role of VV applications across many different market segments. While this is happening, it is necessary to make sure the VV systems and diffusers in particular are applied, installed, and operated correctly. The purpose of this section of the catalog is to show these issues that need to be considered when selecting and placing diffusers. Introduction D 3 Linear Slot Diffusers (LINR) D 4 djustable Flow Diffusers (FPF, VPF, BD, VPS) D Light Fixture Diffusers (LITE) D 6 Induction Diffusers (INDT, INDB, INCB, INSR) D 7 9 Perforated Diffusers (PERF) D 30 3 Mechanical Specifications D DIFFUSER PLENUM (OPTIONL) CONTROL UNIT VV-PRC008-EN D

2 Diffusers Introduction Diffusers The VariTrane line of variable-airvolume (VV) products has been an industry leader in performance and quality for many years. While most would associate the VariTrane name with VV terminal units, the diffuser product line has grown significantly over the years. Room ir Distribution When variable-flow cooling and constant-flow heating are combined in a zone, the zone air diffusers are usually selected at partial cooling load to ensure proper operation. Ceilingmounted linear slot diffusers are recommended since they perform well over a wide range of velocities. Cool air delivery takes advantage of the Coanda effect, whereby cool air discharged through a linear slot diffuser hugs the ceiling before descending, insuring proper operation over a wide range of flows without dumping. When delivering warm air with constant flow velocities, or warm/ cool air with variable flow velocities, the flow velocity must be high enough to ensure that the air reaches the floor. To prevent stratification, the warm air temperature should not be more than 0 F (6.7 C) above the zone air temperature. in the VariTrane line, an explanation of each type, and a short discussion of the proper application for each type. Linear Slot Diffuser (LINR) Linear slot diffusers are most commonly used in VV systems. This type of diffuser has a fixed vane inside, which means that the pattern is not adjustable. The fixed vane allows a wide range of flows through the diffuser without causing drafts. Lower flanges provide ceiling tile support as an integral part of the diffuser housing. Recommended Guidelines Linear Slot Diffusers Diffuser Placement The maximum recommended distance between diffusers is three diffuser lengths. For example, if the diffuser length is 4 feet (.9 m), the maximum separation distance would be 4 ft x 3 = ft (.9 m x 3 = m). The maximum recommended distance for diffusers from an exterior wall, with parallel flow to the wall is two diffuser lengths. For example, if the diffuser length is 4 feet (.9 m), the maximum distance from the exterior wall would be 4 ft x = 8 ft (.9 m x =.438 m). simple rule for better air circulation is to avoid placing supply air linear slot diffusers that allow airflows to collide at right angles. General Guidelines When beginning the placement and layout of diffusers, assume that each diffuser delivers only 75% to 80% of its SUPPLY IR DIFFUSERS NEVER DO THIS!! (PERPENDICULR IR FLOWS) RETURN IR DIFFUSER nominal airflow. If you start by using 00% of the nominal airflow, you will end up with high losses in performance, acoustical problems, and very little or no design flexibility. diffuser airflow rate is 50 cfm per linear foot (77.4 L/s per linear meter) of diffuser. Therefore, the recommended flow to use when designing is 50 cfm/ linear ft x 0.8 = 40 cfm/linear ft (77.4 L/s/ linear m x 0.8 = 6.9 L/s/linear m). The nominal airflow of a diffuser is determined by multiplying the diffuser length, the number of slots, and the airflow per linear foot. Using the airflow per linear foot calculated above, a 4 foot, -slot, -way diffuser should be designed to handle 4 linear ft x slots x 40 cfm/linear ft = 30 cfm (.9 m x slots x 6.9 L/s/linear m = 50.9 L/s). To maximize the effectiveness of ventilation with ceiling diffusers, throws should be kept as long as possible. For proper air circulation, try to maintain at least a 0 F (6.7 C) difference between the supply air and room temperature. This provides for optimum performance. Collision Velocities The collision velocity is the speed at which moving air meets a wall or another airflow In addition to choosing the correct diffuser type, the designer must properly size and place each diffuser in the zone to minimize noise and pressure drop while maximizing the throw and diffusion performance. VariTrane Diffuser Types The VariTrane line of diffusers contains a variety of different models. The following is a list of the diffuser types D VV-PRC008-EN

3 Diffusers Introduction stream. For exterior walls, the collision velocity should be between 00 and 50 feet per minute (FPM) (0.508 and 0.76 m/s). Do not exceed 50 FPM (0.76 m/s) on an exterior wall. For interior walls, the collision velocity should be between 50 and 75 FPM (0.54 and 0.38 m/s). Try not to exceed 75 FPM (0.38 m/s) for interior walls. The maximum recommended collision velocity between airflow streams should not exceed 50 FPM (0.76 m/s). The collision velocity between airflow streams is determined by the addition of both velocities at the point of collision. void collision of air velocities at right angles to each other by trying to maintain parallel flow. Following this guideline will allow one to maximize the "Coanda" effect and proper air diffusion in a zone. Experience indicates that mixed air after collision near the ceiling and below 50 FPM will produce comfort in the zone at the occupant's level. INTERIOR WLL 50 FPM MX. EXTERIOR WLL 75 FPM MX. 50 FPM MX. Return ir Slots Return air slots are placed perpendicular to supply air slots. This prevents supply air from bypassing the space, and allows for proper air circulation. With a suspended ceiling, low operating static pressure across the ceiling panels must be maintained. Failure to do so will cause the return air to be forced around the edges of the ceiling panels. When this happens, soiling of the panels will occur and the mechanical system can become choked for return air. space-to-plenum pressure drop of 0.0 to 0.03 inches of water is acceptable under most conditions. RETURN DIFFUSER SLOT PERPENDICULR SUPPLY DIFFUSER Fully djustable Pattern Flow (FPF) The FPF diffuser, a type of ceiling diffuser outlet, should be used with layin ceilings. The primary benefit of this kind of diffuser is that it provides the most flexibility of adjustment of the airflow pattern. The FPF diffuser provides adjustable vanes for horizontal or vertical throw. The dualvane option allows each slot to be adjusted for left, right, or vertical throw. Besides pattern adjustments, the vanes also provide airflow dampering. In addition, the vanes are adjustable from the face of the diffuser so changes to the pattern can be made after the diffuser is installed. Vane djustable Pattern Flow (VPF) The VPF diffuser is very similar to the FPF ceiling outlet diffusers. The primary difference is the design of the pattern adjustment vane. The VPF diffuser should be used with lay-in ceilings. The pattern is adjustable for horizontal left, horizontal right, or vertical throw. The pattern adjustment vane contains a felt seal on the end to reduce air leakage around the vane. The vanes are adjustable from the face of the diffuser, allowing the pattern to be easily changed after installation. Vane djustable Pattern Flow Special (VPS) The VPS diffuser is a special version of the VPF diffuser. The design of the vane is slightly different from the VPF model, but the VPS has the same functionality. The VPS has been popular in certain regions of the country. djustable ir Bar Diffuser (BD) The BD diffuser is another lay-in ceiling type of diffuser. The difference between the BD and the FPF or the VPF is that the BD has no adjustment vane. sliding air bar in the outlet of the diffuser makes the pattern adjustments. The pattern is adjustable for horizontal left, horizontal right, or vertical throw. Light Fixture Diffuser (LITE) The LITE diffuser should be installed on a suspended ceiling light fixture. This type of diffuser is quite popular with architects, because the number of ceiling penetrations can be reduced. The diffuser is available with an integral sliding volume damper and with or without pattern control vanes (some light fixtures already contain pattern control vanes). Both the volume damper and the pattern control vanes (if necessary) are adjustable with a screwdriver from the face of the diffuser without removing the light fixture doorframe. The pattern control vane allows for either horizontal or vertical throw. Induction Diffusers (INDT, INDB, INSR, INCB) Induction diffuser discharges air in a tight pattern along a ceiling. The discharged air then induces the room air into the air stream to effectively mix the streams. Induction diffusers are typically used in exterior zones that have unusually high heat loads or drafts. They are designed to be installed in suspended ceilings and have high induction horizontal airflow. The center down blow option provides a vertical air pattern for exterior walls or glass. Induction diffusers have adjustable blades for volume and direction control. INDT This type of induction diffuser contains a supply air outlet only. It will project air along a ceiling and provide mixing of the primary and room air streams. INDT This type of induction diffuser contains a standard supply air outlet along with down blow outlet. The down blow outlet will project a jet of primary air in a vertical direction while the standard outlet projects the induction jet. The down blow jet is often washed along an exterior glass window or aimed to combat something that is producing a draft in the space. INSR This type of induction diffuser contains a supply air outlet along with a separate return air inlet integrated into one device. This reduces the number of ceiling penetrations necessary. INCB This type of induction diffuser contains a standard supply air outlet, a down blow outlet, and a separate return air inlet integrated into one device. Perforated Diffuser (PERF) The PERF diffusers are designed for use with lay-in ceilings and provide the most economical option for air diffusion. The pre-assembled diffuser is made to lay in a 4" x 4" (0.60 m x 0.60 m) ceiling opening and is available with multiple round inlet connection sizes. Outlets are available with disc or adjustable deflector. The air is projected in a circular pattern from the diffuser. VV-PRC008-EN D 3

4 Linear Slot Model Number Description Linear Slot Diffusers The features of the Linear Slot Diffuser are described by the product categories shown in bold. Within each category the options available are listed. MODL Model VLSD Supply Diffuser VLRD Return Slot DSEQ Design Sequence Design Sequence TYPE Diffuser Type LINR Linear Diffuser LGTH Diffuser Length Diffuser Length '.5 Diffuser Length /' 4 Diffuser Length 4' 5 Diffuser Length 5' HGTH Diffuser Height LOW Low Height MED Medium Height HIGH High Height NONE For Return Slots WDTH Ceiling Tee Width 96 9/6" Ceiling Grid 56 5/6" Ceiling Grid SLOT Slot Configuration SW -Slot, -Way SW -Slot, -Way 3SW 3-Slot, -Way SW -Slot, -Way 4SW 4-Slot, -Way SDR -Slot, Direct Discharge 3SI 3-Slot, Way, Inlet on -Slot Side 3SI 3-Slot, Way, Inlet on -Slot Side SDR -Slot, Direct Discharge CEIL Ceiling Type TBR 5/6" T-Bar XT 5/6" T-Bar with Center Notch PLSR Plaster Ceiling T96 9/6" Narrow Faced Grid D96 9/6" Narrow Regressed Grid XN 9/6" Center Notch, Narrow Faced Grid XD 9/6" Center Notch, Narrow Regressed Grid SPLN Concealed Spline DMPR Damper Type FIRE Fire Damper BL Balancing Damper HNGR Hanger Holes WITH Hanger Holes D 4 VV-PRC008-EN

5 Linear Slot Ceiling Cross Reference CEILING SYSTEM CROSS REFERENCE (TYP. LL) ½ GRID TYPE 5/6"GRID STNDRD T-BR GRID (T-BR, xt) COMPNY/NME OR MODEL RMSTRONG PRELUDE SERIES CHICGO METLLIC 00/800 SERIES USG/DONN DX SERIES 5/6 ½ 9/6" GRID NRROW FCED GRID (T96, xn) RMSTRONG SUPRFINE CHICGO METLLIC TEMPR 4000 USG/DONN CENTRICITEE 9/6 ½ REVEL GRID NRROW FCED GRID (T96, xn) CHICGO METLLIC STYLINE 3700 (9/6") USG/DONN DX MERIDIN (9/6") 9/6 ½ REVEL GRID NRROW FCED GRID (T96, xn) CHICGO METLLIC STYLINE 3800 (3/4") 3/4 5/6 BOLT SLOT GRID (FINELINE TYPE) NRROW REGRESSED GRID (D96, xd) RMSTRONG SILHOUETTE (¾" HEIGHT) CHICGO METLLIC ULTRLINE 3500/3600 USG/DONN FINELINE ( 5/3" HEIGHT) GORDON INC. SIMPLICITY -SERIES 9/6 5/6 SCREW SLOT GRID (EXTRUDED LUMINUM) NRROW REGRESSED GRID (D96, xd) RMSTRONG TRIMLOK USG/DONN HIGHLINE GORDON INC. SIMPLICITY B-SERIES 9/6 NOTES:. T-BR HEIGHTS RNGE FROM ½" ¼". CHECK WITH FCTORY TO SSURE COMPTIBILITY BEFORE SPECIFYING DIFFUSERS FOR THESE TYPES OF GRIDS.. LL DIMENSIONS RE IN INCHES. VV-PRC008-EN D 5

6 Linear Slot Dimensional LINR LINR INLET BLNCING DMPER (OPTIONL) INTERNL INSULTION H NOMINL LENGTH W END BRCKET DETIL DIFFUSER HEIGHT H LOW MED HIGH INLET DIMETER 6" 8" 0" INLET DIMETERS RE BSED ON COMBINTION OF CEILING TYPE ND DIFFUSER LENGTH. SEE CHRT ON INLET VILBILITY. MODEL NUMBER SW SW SW 3SW 3SI 3SI 4SW DIFFUSER WIDTH W TILE FLNGE DETIL SW -SLOT -WY SW -SLOT -WY SW -SLOT -WY 3SW 3-SLOT -WY 3SI 3-SLOT -WY 3SI 3-SLOT -WY 4SW 4-SLOT -WY NOTES:. FIXED VNE PROVIDES DRFTLESS IR PTTERN OVER THE FULL RNGE OF FLOW. EXCELLENT FOR VRIBLE VOLUME.. LOWER FLNGES PROVIDE TILE SUPPORT S N INTEGRL PRT OF THE DIFFUSER HOUSING. 3. VILBLE IN NOMINL LENGTHS OF ',.5', 4', ND 5'. 4. MTERIL: 4-GGE GLVNNELED STEEL. 5. LL EXPOSED SURFCES HVE WHITE ENMEL FINISH. 6. LL DIMENSIONS RE IN INCHES. SDR -SLOT Direct Discharge SDR -SLOT Direct Discharge D 6 VV-PRC008-EN

7 Linear Slot Dimensional LINR LINR OPEN RETURNS NOMINL LENGTH END BRCKET DETIL 5 5 SW NOTES:. LOWER FLNGES PROVIDE TILE SUPPORT S N INTEGRL PRT OF THE DIFFUSER HOUSING.. VILBLE IN NOMINL LENGTHS OF ',.5', 4', ND 5'. 3. LL EXPOSED SURFCES HVE WHITE ENMEL FINISH. 4. RETURNS RE MDE OF 4-GGE GLVNNELED STEEL. 5. LL DIMENSIONS RE IN INCHES. VV-PRC008-EN D 7

8 Linear Slot Dimensional LINR ONE WY LINER SLOT DIFFUSER OR RETURN SLOT U.L. Listed Fusible Link Fire Damper 0-gage Steel SW SW 3SW -SLOT -SLOT 3-SLOT -WY -WY -WY TWO WY LINER SLOT DIFFUSER OR RETURN SLOT U.L. Listed Fusible Link Fire Damper 0-gage Steel SW -SLOT -WY 3SI 3-SLOT -WY 3SI 3-SLOT -WY 3SI 3-SLOT -WY 4SW 4-SLOT -WY Notes:. Spring loaded dampers blades are hinged and held open by 58 F (70 C) fusible links.. This drawing is for pictorial view only and not to be used for dimensional purposes. 3. The UL Reference R6700 VOLUME (-SLOT and -SLOT models only). D 8 VV-PRC008-EN

9 Linear Slot Dimensional LINR SLOT DIFFUSER SURFCE MOUNT FRMES FOR PLSTER CEILING CTUL 3 DIFFUSER + LENGTH W DIFFUSER WIDTH ¾ ¾ DIFFUSER CLIP MODEL DIFFUSER NUMBER SW SW 3SW 3SI FRME CEILING 3SI 4SW SECTION DETIL (INSTLLED) VV-PRC008-EN D 9

10 Linear Slot Inlet vailability Linear Slot Diffusers Inlet vailability 4" Length 30" Length 48" Length 60" Length Ceiling Type Slot rrangement Low Med High Low Med High Low Med High Low Med High 5/6" T-Bar -slot, -way 5" 5" 5" 5" 6" 6" 6" 6" Plaster -slot, -way 6" 6" 8" 8" 3-slot, -way 8" 8" 0" 0" -slot, -way 6" 6" 6" 6" 6" 6" 8"o* 8" 8" 8"o* 8" 8" 3-slot, -way 8" 8" 0" - 0" 4-slot, -way 8" 8" 0" 0" 5/6" T-Bar -slot, -way 6" 6" with Center -slot, -way 8" Notch 3-slot, -way 0" ( x T) -slot, -way 8"o* 8" 8" 3-slot, -way 0" 4-slot, -way 0" 9/6" Narrow -slot, -way 5" 5" 6" 6" 6" 6" Faced Grid or -slot, -way 6" 8" 8" 9/6" Narrow 3-slot, -way 8" 0" 0" Regressed Grid -slot, -way 6" 8" 0" 6" 8" 0" 6" 8" 0" 6" 8" 0" Or Concealed 3-slot, -way 0" 0" 0" 0" Spline 4-slot, -way 0" 0" 0" 0" 9/6" Center -slot, -way 6" 6" Notch Narrow -slot, -way 8" Faced Grid or 3-slot, -way 0" 9/6" Center -slot, -way 6" 8" 0" Notch Narrow 3-slot, -way 0" Regressed Grid 4-slot, way 0" Note: *O- Oval D 0 VV-PRC008-EN

11 Linear Slot Performance LINR Table - Style LINR Diffuser Performance Supply Slot Performance ' SW Cfm TSP Throw NC (0) (0) (0) 7 SW Cfm TSP Throw NC (0) (0) (0) 6 3 SW Cfm TSP Throw NC (0) (0) (0) 7 3SW Cfm TSP Throw NC (0) (0) (0) 6 3 3SW Cfm TSP Throw Throw NC (0) (0) (0) 6 3 4SW Cfm TSP Throw NC (0) (0) 9 36 Supply Slot Performance 4' SW Cfm TSP Throw NC (0) (0) (0) 6 3 SW Cfm TSP Throw NC (0) (0) SW Cfm TSP Throw NC (0) (0) (0) 6 3 3SW Cfm TSP Throw NC (0) (0) SW Cfm TSP Throw Throw NC (0) (0) SW Cfm TSP Throw NC (0) (0) Return Slot Performance ' SW Cfm SP SW Cfm SP Return Slot Performance.5' SW Cfm SP SW Cfm SP Return Slot Performance 4' SW Cfm SP SW Cfm SP Return Slot Performance 5' SW Cfm SP SW Cfm SP Supply Slot Performance.5' SW Cfm TSP Throw NC (0) (0) (0) 3 8 SW Cfm TSP Throw NC (0) (0) (0) 7 3 SW Cfm TSP Throw NC (0) (0) (0) 3 8 3SW Cfm SP Throw NC (0) (0) (0) SI Cfm SI TSP Throw Throw NC (0) (0) (0) SW Cfm TSP Throw Supply Slot Performance 5' SW Cfm TSP Throw NC (0) (0) SW Cfm TSP Throw NC (0) (0) SW Cfm TSP Throw NC (0) (0) SW Cfm TSP Throw NC (0) (0) SW Cfm TSP Throw Throw NC (0) (0) SW Cfm TSP Throw NC (0) (0) NC (0) (0) TSP - Static pressure readings in in. wg. Throw - Horizontal distance in feet to reach terminal velocity, VT, of 50 FPM. Throw and Throw indicates number of slots throwing each direction on 3-slot, -way diffuser. NC - one number evaluation of sound generation derived from sound power levels (re: 0- watts) less 0 db room absorption. (0) indicates less than 0 NC rating. Data shown is for one diffuser. dditional diffusers will tend to increase the NC value by perhaps db each, depending on size, air quantity and distance from other diffusers. Return applications will add + db to all values shown. Performance data is based on tests performed in accordance with DC 06 GRD-84 Test Code. VV-PRC008-EN D

12 djustable Flow Model Number Description djustable Flow Diffusers The features of the djustable Flow Diffuser are described by the product categories shown in bold. Within each category the options available are listed. FPF VPF MODL Model VLSD Supply Diffuser VLRD Return DSEQ Design Sequence Design Sequence TYPE Diffuser Type FPF Fully djustable Pattern Flow Diffuser VPF Vane djustable Pattern Flow Diffuser BD djustable ir Bar Diffuser VPS Vane djustable Pattern Flow Diffuser LGTH Diffuser Length Diffuser Length ' 3 Diffuser Length 3' 4 Diffuser Length 4' 5 Diffuser Length 5' Diffuser Length " 34 Diffuser Length 34" 46 Diffuser Length 46" 58 Diffuser Length 58" 4 Diffuser Length 3 3/4" 36 Diffuser Length 35 3/4" 48 Diffuser Length 47 3/4" 60 Diffuser Length 59 3/4" HGTH Diffuser Height LOW Low Height MED Medium Height HIGH High Height WDTH Ceiling Tee Width 9/6 Ceiling Grid 9/6" 56 Ceiling Grid 5/6" SLOT Slot Configuration SLT Slot SLT Slot 3SLT Slot 3 4SLT Slot 4 CEIL Ceiling Type TBR T-bar 5/6" T96 Narrow Faced T-bar 9/6" XT Center Notched Grid 5/6" XN Narrow Faced Center Notch 9/6" XD Narrow Regressed Cntr Notch 9/6" PLSR Plaster Ceiling D96 Narrow Regressed T-bar - 9/6" SPLN Concealed Spline DMPR Damper Type BL Balancing Damper DISW.5 /".75 3/4".0 ".5 /4".5 /".0 ".5 /4".5 /" STYL Diffuser Style NONE For VPF, BD, and VPS -slot one way -slot -way left or right 3 -slot -way with factory-installed T-bar 4 -slot -way left or right with factory-installed T-bar 5 -slot -way with factory-installed T-bars 6 -slot -way left or right with factory-installed T-bars -slot -way opposite -slot -way opposite left or right 3 -slot -way opposite with factory-installed T-bar 4 -slot -way opposite left or right with factory-installed T-bar 5 -slot -way opposite with factory-installed T-bars 6 -slot -way opposite left or right with factory-installed T-bars 7 -slot -way opposite with 3 factory-installed T-bars 8 -slot -way opposite left or right with 3 factory-installed T-bars 9 -slot -way opposite with factory-installed T-bars 33 3-slot -way 34 3-slot -way left or right 43 -slot -way opposite 44 4-slot -way opposite left or right D VV-PRC008-EN

13 djustable Flow Dimensional VPF VPF INLET DI +3 INLET DIMETER 6" 8" 0" HEIGHT LOW - 9" MED - " HIGH - 3" NOMINL LENGTH - ¼ NOMINL LENGTH INLET DMPER (OPTIONL) ½ INTERNL INSULTION 9 6 B B B CENTER T - BR STNDRD ON, 3, 4 SLOT T - BR CLIPS (OPTIONL) B SIDE T - BRS (OPTIONL) NOTES:. MTERIL: 4-GGE GLVNNELED STEEL. LL EXPOSED SURFCES PINTED FLT BLCK. T - BRS RE WHITE.. VILBLE IN NOMINL LENGTHS OF ', 3', 4', & 5'. 3. LUMINUM VNE WITH FELT SEL IS FULLY DJUSTBLE FROM THE FCE FOR LEFT, RIGHT, OR VERTICL THROW. 4. DESIGNED FOR VRIBLE OR CONSTNT VOLUME SYSTEMS. 5. MXIMUM PERFORMNCE ND FLEXIBILITY FOR INTERIOR OR PERIMETER PPLICTIONS IN VRIETY OF CEILING SYSTEMS. 6. LL DIMENSIONS RE IN INCHES SLOT WIDTH 3" 4 " " DIFFUSER WIDTH B -SLOT -SLOT 3-SLOT 4-SLOT 7" 5" 3 5" " " " " " 5" " 9" " VV-PRC008-EN D 3

14 djustable Flow Performance VPF Style VPF Diffuser Performance -Slot '.75 Cfm (k.05) TSP (Low) Throw NC (0) (0) (0) (0) Cfm (k.06) TSP (Low) Throw NC (0) (0) (0) Cfm (k.) TSP (Med) Throw NC (0) (0) (0) Slot 4'.75 Cfm (k.0) TSP (Low) Throw NC (0) (0) (0) Cfm (k.) TSP (Med) Throw NC (0) (0) (0) Cfm (k.) TSP (Med) Throw NC (0) (0) (0) Slot 5'.75 Cfm (k.) TSP (Med) Throw NC (0) (0) (0) Cfm (k.4) TSP (High) Throw NC (0) (0) Cfm (k.8) TSP (High) Throw NC (0) (0) (0) Slot '.75 Cfm (k.0) TSP (Low) Throw NC (0) (0) (0) Cfm (k.) TSP (Low) Throw NC (0) (0) (0) Cfm (k.) TSP (Med) Throw NC (0) (0) (0) Slot 4'.75 Cfm (k.9) TSP (Med) Throw NC (0) (0) (0) Cfm (k.) TSP (Med) Throw NC (0) (0) (0) D 4 -Slot 5'.75 Cfm (k.4) TSP (High) Throw NC (0) (0) (0) Cfm (k.8) TSP (High) Throw NC (0) (0) Slot '.75 Cfm (k.4) TSP (Med) Throw NC (0) (0) (0) Cfm (k.7) TSP (Med) Throw NC (0) (0) (0) Cfm (k.33) TSP (High) Throw NC (0) (0) (0) Slot 4'.75 Cfm (k.9) TSP (High) Throw NC (0) (0) (0) Cfm (k.34) TSP (High) Throw NC (0) (0) Slot '.75 Cfm (k.9) TSP (Med) Throw NC (0) (0) (0) Cfm (k.) TSP (Med) Throw NC (0) (0) (0) Cfm (k.44) TSP (High) Throw NC (0) (0) (0) (0) Slot 4'.75 Cfm (k.39) TSP (High) Throw NC (0) (0) (0) TSP - Total pressure readings in in. wg with horizontal throw. k - rea factor along with cfm is used to determine the average face velocity - Vk = cfm / k Throw - Horizontal distance in feet to reach terminal velocity, VT, of 50 FPM. NC - one number evaluation of sound generation derived from sound power levels ( re: 0- watts) less 0 db room absorption. (0) indicates less than 0 NC rating. Data shown is for one diffuser. dditional diffusers will tend to increase the NC value by perhaps db each, depending on size, air quantity and distance from other diffusers. Return applications will add + db to all values shown. Peformance data is based on tests performed in accordance with DC 06 GRD-84 Test Code. VV-PRC008-EN

15 djustable Flow Dimensional VPS VPS Inlet Damper (Optional) " Insulation Length Inlet Diameter LENGTH " 34" 46" 58" 4" (3-3/4") 36" (35-3/4") 48" (47-3/4") 60" (59-3/4") INLET 6" 7" 8" 0" OVL 6" 7" 8" 0" OVL 3 " 6 3" 7" 8 7" 8 " 3" 6 3" 6 3" 6 3" 6 3" 6 3" 6 Open Return Supply Diffuser Notes:. Material: 4-gage galvannealed steel with exposed surfaces and pattern controller painted flat black.. Neck opening is located so that the bottom of inlet is above air pattern controller throughout the range of settings including vertical. 3. VPS diffusers are only available for 5/6" T-Bar and 5/6" center notched grid ceilings. 4. ll dimensions are in inches. VV-PRC008-EN D 5

16 djustable Flow Dimensional FPF FPF and SLOT B + INSULTION INLET DI +3 NOMINL LENGTH - ¼ NOMINL LENGTH DMPERS (OPTIONL) INLET DIMETER 6" 8" 0" HEIGHT LOW - 9.5" MED -.5" HIGH - 3.5" SLOT WIDTH OVERLL WIDTH B B ONE SLOT SUPPLY B ONE SLOT TWO SLOT " 3" " " " " " " " 3" " " 3" " " " " 3 3" 3" 3" T-CLIPS (OPTIONL) B TWO SLOT SUPPLY NOTES:. DJUSTBLE VNES FOR HORIZONTL OR VERTICL THROW. DUL VNE OPTION LLOWS ECH SLOT TO BE DJUSTED FOR LEFT, RIGHT OR VERTICL THROW ND DMPERING.. DIFFUSERS OVER 36" LONG HVE VNES MDE IN TWO SEPRTE PIECES TO LLOW SPLITTING IR FLOW SETTINGS WITHIN ECH SLOT. D B D + 3 ONE SLOT RETURN B TWO SLOT RETURN 3. VILBLE IN NOMINL LENGTHS FROM ', 3', 4', ND 5'. 4. MTERIL: 4-GGE GLVNNELED STEEL. 5. LL EXPOSED SURFCES PINTED FLT BLCK. FCTORY- INSTLLED T-BRS RE WHITE. 6. LL DIMENSIONS RE IN INCHES. SLOT WIDTH OVERLL WIDTH B OUTLET HEIGHT D ONE SLOT TWO SLOT " 3" " " " 3" " " " " " 3" " " " 3" " 3" 3" " " 3" " " " " " " " 3" 4 4 STYLES: ONE SLOT TWO SLOT D 6 VV-PRC008-EN

17 djustable Flow Dimensional FPF FPF 3 and 4 SLOT INLET DMPER (OPTIONL) INSULTION INLET DI + 3½ NOMINL LENGTH - ¼ INLET DIMETER HEIGHT ½ ½ 6" LOW - 9.5" 8" 0" MED -.5" HIGH - 3.5" B SIDE T-BRS (OPTIONL) CENTER T-BRS (STNDRD) NOTES:. VILBLE IN NOMINL LENGTHS FROM TO 5 FEET.. MTERIL: 4-GGE GLVNNELED STEEL. 3. LL EXPOSED SURFCES PINTED FLT BLCK. FCTORY-INSTLLED T-BRS RE WHITE. 4. LL DIMENSIONS RE IN INCHES. SLOT WIDTH OVERLL WIDTH B THREE SLOT FOUR SLOT 3" 3" 3" 4 " " " 4 4 5" " 3" 5" 5" 5" PTTERN CONFIGURTIONS SINGLE VNES LLOW ECH SLOT TO THROW IN ONE HORIZONTL DIRECTION OR VERTICL. SPECIFY THE NUMBER OF SLOTS TO THROW IN ECH DIRECTION. EX: (STYL 33) (STYL 43) DUL VNES LLOW ECH SLOT TO BE DJUSTED FOR RIGHT, LEFT OR VERTICL THROW. (STYL 34) (STYL 44) VV-PRC008-EN D 7

18 djustable Flow Performance FPF Style FPF Diffuser Performance -Slot '.5 Cfm TSP Throw NC (0) (0) Cfm TSP Throw NC (0) (0) Cfm TSP Throw NC (0) (0) (0) Cfm TSP Throw NC (0) (0) (0) Cfm TSP Throw NC (0) (0) (0) (0) Slot 4'.5 Cfm TSP Throw NC (0) (0) (0) Cfm TSP Throw NC (0) (0) Cfm TSP Throw NC (0) (0) Cfm TSP Throw NC (0) (0) Cfm TSP Throw NC (0) (0) (0) (0) (0) Slot 5'.50 Cfm TSP Throw NC (0) (0) (0) D 8 VV-PRC008-EN

19 djustable Flow Performance FPF Style FPF Diffuser Performance (con't.) -Slot '.5 Cfm TSP Throw NC (0) (0) (0) (0) Cfm TSP Throw NC (0) Cfm TSP Throw NC (0) Cfm TSP Throw NC (0) Cfm TSP Throw NC (0) (0) (0) (0) (0) Slot 4'.5 Cfm TSP Throw NC (0) (0) (0) Cfm TSP Throw NC (0) (0) Cfm TSP Throw NC (0) (0) Cfm TSP Throw NC (0) (0) (0) Cfm TSP Throw NC (0) (0) (0) (0) (0) (0) Slot 5'.50 Cfm TSP Throw NC (0) (0) (0) (0) (0) (0) (0) TSP - Total pressure readings in in. wg with horizontal throw. Throw - Horizontal distance in feet to reach terminal velocity, VT, of 50 FPM. NC - one number evaluation of sound generation derived from sound power levels ( re: 0- watts) less 8 db room absorption. (0) indicates less than 0 NC rating. Data shown is for one diffuser. dditional diffusers will tend to increase the NC value by perhaps db each, depending on size, air quantity and distance from other diffusers. Return applications will add + db to all values shown. Performance data is based on tests performed in accordance with DC 06 GRD-84 Test Code. VV-PRC008-EN D 9

20 djustable Flow Dimensional BD BD INLET DI + 3½ NOMINL LENGTH INTERNL INSULTION INLET DMPER (OPTIONL) ½ INLET DIMETER HEIGHT 6" LOW 9.5" 8" MED.5" 0" HIGH 3.5" ½ ½ T-CLIPS (OPTIONL) NOTES:. SLIDING IR BR PROVIDES LEFT, RIGHT, OR VERTICL THROW.. DIFFUSERS OVER 36" IN LENGTH HVE TWO IR BRS PER SLOT TO LLOW SPLIT IR PTTERNS. B B T-BRS BY OTHERS 3. VILBLE IN NOMINL LENGTHS FROM ' TO 5'. NORML T-BR PPLICTION IS NORML LENGTH LESS ¼". 4. MTERIL: 4-GGE GLVNNELED STEEL. LL EXPOSED SURFCES PINTED BLCK. 5. ONLY VILBLE FOR 5/6" T-BR ND CENTER NOTCHED GRID (XT) CEILING ONLY. 6. LL DIMENSIONS RE IN INCHES. ONE SLOT TWO SLOT SLOT WIDTH OVERLL WIDTH B D 0 VV-PRC008-EN

21 djustable Flow Performance BD Style BD Diffuser Performance -Slot 4'.75 Cfm (Low) TSP Throw NC (0) Cfm (Med) TSP Throw NC Cfm (Med) TSP Throw NC (0) Cfm (Med) TSP Throw NC (0) (0) Cfm (Med) TSP Throw NC (0) Cfm (Med) TSP Throw NC (0) Cfm (Med) TSP Throw NC Slot 4'.75 Cfm (Med) TSP Throw NC Cfm (Med) TSP Throw NC Cfm (High) TSP Throw NC (0) Cfm (High) TSP Throw NC (0) UNIT LENGTH FCTORS Multiply 48" data by the following factors: Nominal Length TSP Throw NC 4" x 3.0 x.0 x.4 36" x.4 x.5 x. 60" x 0.8 x 0.9 x.0 TSP - Static pressure readings in in. wg. Throw - Horizontal distance in feet to reach terminal velocity, VT, of 50 FPM. NC - one number evaluation of sound generation derived from sound power levels ( re: 0- watts) less 0 db room absorption. (0) indicates less than 0 NC rating. Data shown is for one diffuser. dditional diffusers will tend to increase the NC value by perhaps db each, depending on size, air quantity and distance from other diffusers. Return applications will add + db to all values shown. Peformance data is based on tests performed in accordance with DC 06 GRD-84 Test Code. VV-PRC008-EN D

22 Light Fixture Model Number Description Light Fixture Diffusers MODL Model The features of the Light Fixture Diffuser are described by the product categories shown in bold. Within each category the options available are listed. VLSD - SNGL with Side Inlet VLSD Supply Diffuser VLRD Return Diffuser DSEQ Design Sequence Design Sequence TYPE Diffuser Type SNGL Single Side Diffuser DUL Dual Side Diffuser LGTH Diffuser Length Diffuser Length ' 3 Diffuser Length 3' 4 Diffuser Length 4' x Light Fixture Diffuser Size ' x ' 3x3 Light Fixture Diffuser Size 3' x 3' x4 Light Fixture Diffuser Size ' x 4' x4 Light Fixture Diffuser Size ' x 4' 4x4 Light Fixture Diffuser Size 4' x 4' INLT Inlet Size nd Location S5 5 Side Inlet S6 6 Side Inlet T5 5 Top Inlet T6 6 Top Inlet T7 7 Top Inlet T8 8 Top Inlet INSL Insulation NONE No Insulation On Diffuser INT Matte-Faced Internally Insulated EXT Foil-Faced Externally Insulated VLSD-Dual with Side Inlet VLSD-DUL with Top Inlet D VV-PRC008-EN

23 Light Fixture Dimensional VLSD SNGL VLSD SNGL MOUNTING BRCKET INTERNL INSULTION (OPTIONL) VOLUME DMPER CCESSIBLE THROUGH IR SLOT - 4' MODELS HVE TWO INDIVIDUL DMPERS IR PTTERN BR OMITTED WHEN LIGHT FIXTURE RIL IS FURNISHED WITH DEFLECTOR HOLD-DOWN TBS TO LIGN ND LOCK DIFFUSER TO LIGHT FIXTURE IR SLOT (SHIPPED FLT) INSULTION L NONE - STEEL UNINSULTED INT - STEEL WITH /" FOIL FCED EXTERNL INSULTION EXT - STEEL WITH /" FOIL FCED EXTERNL INSULTION INSL - NONE INSL - INT INSL - EXT NOTES:. DIFFUSERS RE VILBLE S SUPPLY UNITS FOR REGRESSED OR FLUSH IR HNDLING LIGHT DIFFUSERS.. MTERIL: GLVNNELED STEEL. EXPOSED SLOT RE PINTED FLT BLCK. 3. HEIGHT: 6¾" STNDRD. CEILING CLERNCE REQUIRED IS 7" PLUS MOUNT LIGHT IS REGRESSED BOVE CEILING LINE. (FOR SINGLE SIDE ONLY) 4. INLETS: 5" OR 6" OVL STNDRD ON SIDE ENTRY. DIFFUSER LENGTH 3 4 IR DIFFUSER LENGTH 0" 7" 40" 5. LL SUPPLY DIFFUSERS INCLUDE PLENUM, INSULTION (WHEN SPECIFIED) ND DUCT CONNECTION. 6. INSULTION IS U.L. LISTED ND MEETS NFP 90 ND U.L STNDRD DIFFUSER LENGTHS RE STTED. CTUL LENGTH WILL VRY WITH LIGHT MNUFCTURER. TO INSURE COMPTIBILITY, LIST LIGHT MNUFCTURER ND MODEL NUMBER. INLET S5-5" SIDE INLET S6-6" SIDE INLET 8. LL DIMENSIONS RE IN INCHES. VV-PRC008-EN D 3

24 Light Fixture Dimensional VLSD DUL VLSD DUL D 4 VV-PRC008-EN

25 Light Fixture Dimensional VRLD SNGL VRLD SNGL OPEN RETURNS MOUNTING BRCKET (SHIPPED FLT) 3 LENGTH INTERNL INSULTION (OPTIONL) VOLUME DMPER CCESSIBLE THROUGH IR SLOT - 4' MODELS HVE TWO INDIVIDUL DMPERS HOLD-DOWN TBS TO LIGN ND LOCK DIFFUSER TO LIGHT FIXTURE IR SLOT (SHIPPED FLT) INSULTION NONE - STEEL UNINSULTED INT - STEEL WITH ½" INTERNL MTTE FCED INSULTION INSL - NONE NOTES:. DIFFUSERS RE VILBLE S RETURN UNITS. FOR REGRESSED OR FLUSH IR HNDLING LIGHT DIFFUSERS.. MTERIL: GLVNNELED STEEL EXPOSED RE PINTED FLT BLCK. 3. INSULTION IS U.L. LISTED ND MEETS NFP 90 ND U.L HEIGHT: 3½" STNDRD. CEILING CLERNCE REQUIRED IS 3¾" PLUS MOUNT LIGHT IS REGRESSED BOVE CEILING LINE. 5. STNDRD DIFFUSER LENGTHS RE STTED. CTUL LENGTH WILL VRY WITH LIGHT MNUFCTURER. TO INSURE CMPTIBILITY, LIST LIGHT MNUFCTURER ND MODEL NUMBER. 6. LL DIMENSIONS RE IN INCHES. LENGTH 3 4 IR DIFFUSER LENGTH 0" 7" 40" VV-PRC008-EN D 5

26 Light Fixture Performance VLSD Style LITE Diffuser Performance VLSD-SNGL Side inlet ' Cfm Throw-V Throw-H TSP-5" TSP-6" NC (0) (0) VLSD-SNGL Side inlet 3' Cfm Throw-V Throw-H TSP-5" TSP-6" NC (0) (0) (0) VLSD-SNGL Side inlet 4' Cfm Throw-V Throw-H TSP-5" TSP-6" NC (0) (0) (0) VLSD-DUL Top inlet CFM Throw-V Throw-H TSP-5" TSP-6" NC (0) (0) (0) VLSD-DUL Top inlet 3 CFM Throw-V Throw-H TSP-5" TSP-6" NC VLSD-DUL Top inlet 4 CFM Throw-V Throw-H TSP-5" TSP-6" NC (0) (0) VLSD-DUL Side Inlet ' Cfm Throw-V Throw-H TSP-5" TSP-6" NC (0) (0) (0) VLSD-DUL Side Inlet 3' Cfm Throw-V Throw-H TSP-5" TSP-6" NC (0) VLSD-DUL Side Inlet 4' Cfm Throw-V Throw-H TSP-5" TSP-6" NC (0) (0) (0) Projection - V and H are vertical and horizontal distance in feet to reach terminal velocities of 00 FPM and 50 FPM respectively. TSP - Static pressure drop in in. wg across the diffuser with dampers full open and horizontal air projection. NC - one number evaluation of sound generation derived from sound power levels ( re: 0- watts) less 8 db room absorption. (0) indicates less than 0 NC rating. Data shown is for one diffuser. dditional diffusers will tend to increase the NC value by perhaps db each, depending on size, air quantity and distance from other diffusers. Return applications will add + db to all values shown. Performance data is based on tests performed in accordance with DC 06 GRD-84 Test Code. D 6 VV-PRC008-EN

27 Induction Induction Diffusers The features of the Induction Diffuser are described by the product categories shown in bold. Within each category the options available are listed. Model Number Description MODL VLSD DSEQ TYPE INDT INDB INCB Model Supply Diffuser Design Sequence Design Sequence Diffuser Type Induction, Supply Only Induction, Down Blow, Supply Only Induction, Down Blow, Supply/Return Induction, Supply/Return Diffuser Length INSR LGTH Diffuser Length - ' 3 Diffuser Length - 3' 4 Diffuser Length - 4' 5 Diffuser Length - 5' CEIL Ceiling Type TBR Tbar - 5/6 XT Center Notch Grid - 5/6 PLSR Plaster Ceiling DMPR Damper Type BL Balancing Damper VV-PRC008-EN D 7

28 Induction INDT, INDB, INSR, INCB Dimensional INDT, INDB, INSR, INCB SUPPLY DIFFUSER SUPPLY DIFFUSER WITH DOWNBLOW B (INDT) (INDB) B B B SUPPLY/RETURN DIFFUSER SUPPLY/RETURN WITH DOWNBLOW B (INSR) (INCB) B B B SUPPLY DIFFUSER SUPPLY/RETURN DIFFUSER Internal insulation Internal insulation INLET SIZE DIFFUSER HEIGHT H = 6 = 6 Vane Detail (T-BR by other) Notes:. High induction horizontal air flow.. Center down blow option provides a veritcal air pattern for exterior walls or glass. djustable Blades for volume and direction control. 3. Supply/Return combination diffusers allow room air to be returned to ceiling plenum. 4. Nominal lengths of ', 3', 4', and 5'. ctual length is nominal minus /4 inch. 5. Material: 4-gage galvannealed steel. ll exposed surfaces painted flat black. 6. ll dimensions are in inches. D 8 VV-PRC008-EN

29 Induction Performance INDUCT Style INDUCT Diffuser Performance Supply Slot Performance INDT, INSR ' Cfm TSP Throw NC (0) (0) (0) (0) (0) 6 9 3' Cfm TSP Throw NC (0) (0) (0) ' Cfm TSP Throw NC (0) (0) ' Cfm TSP Throw NC (0) Supply Slot Performance with Down Blow INDB, INCB 3' Cfm TSP Throw H Throw V NC ' Cfm TSP Throw H Throw V NC (0) ' Cfm TSP Throw H Throw V NC (0) Return Slot Performance INSR, INCB Cfm/Ft Neg. SP TSP - Static pressure readings in in. wg. Throw - Horizontal distance in feet to reach terminal velocity, VT, of 50 FPM. Vertical throw values are based on standard " long down blow slot and 3/8" width setting. NC - one number evaluation of sound generation derived from sound power levels (re: 0- watts) less 8 db room absorption. (0) indicates less than 0 NC rating. Data shown is for one diffuser. dditional diffusers will tend to increase the NC value by perhaps db each, depending on size, air quantity and distance from other diffusers. Return applications will add + db to all valves shown. Performance data is based on tests performed in accordance with DC 06 GRD-84 Test Code. VV-PRC008-EN D 9

30 Perforated Model Number Description Perforated Diffusers The features of the Perforated Diffuser are described by the product categories shown in bold. Within each category the options available are listed. MODL VLSD VLRD DSEQ DEFL DJ DISC NONE TYPE PERF Model Supply Diffuser Return Diffuser Design Sequence Design Sequence Deflector djustable Deflector Disc Deflector No Deflector Diffuser Type Perforated Diffuser CEIL Ceiling Type TBR T-bar 5/6" T96 Narrow Faced Grid 9/6" D96 Narrow Regressed Grid 9/6" INLT Inlet Size nd Location 6 6" Round Inlet, Top 8 8" Round Inlet, Top 0 0" Round Inlet, Top " Round Inlet, Top 4 4" Round Inlet, Top DMPR Damper Type BFLY Butterfly Damper D 30 VV-PRC008-EN

31 Perforated Dimensional PERF PERF BUTTERFLY DMPER (OPTIONL FOR VLSD ONLY) ½ 6 T-BRS DISC OR DJUSTBLE DEFLECTOR (FOR VLSD ONLY) 4" CENTERS DEFL DJ DISC DEFLECTOR (VLSD ONLY) DJUSTBLE DEFLECTOR (VLSD ONLY) NO DEFLECTOR (VLRD ONLY) INLT " TOP INLET 8" TOP INLET " TOP INLET 4" TOP INLET NOTES:. COMPLETELY SSEMBLED FOR ESY LY-IN INSTLLTION.. -GGE PERFORTED STEEL FCE WITH WHITE FINISH ND 5% OPEN RE GGE STEEL PLENUM WITH BLCK INTERIOR. THE FCE FOR LEFT, RIGHT, OR VERTICL THROW. 4. ROUND INLET SIZES 6" THROUGH 4". 5. VILBLE WITH DISC OR DJUSTBLE DEFLECTOR. 6. LL DIMENSIONS RE IN INCHES. VV-PRC008-EN D 3

32 Perforated Performance PERF Table - Style PERF Diffuser Performance 4 x 4 Nominal size Inlet Size 6 Cfm TSP Throw NC Cfm TSP Throw NC Cfm TSP Throw NC Cfm TSP Throw NC Cfm TSP Throw NC TSP - Total pressure readings in in. wg across diffuser. Throw - Horizontal distances in feet to reach terminal velocity, VT, of 50 FPM. NC - one number evaluation of sound generation derived from sound power levels (re: 0- watts) less 0 db room absorption. (0) indicates less than 0 NC rating. Data shown is for one diffuser. dditional diffusers will tend to increase the NC value by perhaps db each, depending on size, air quantity and distance from other diffusers. Return applications will add + db to all valves shown. Performance data is based on tests performed at Donco ir Products and ETL Laboratories in accordance with DC 06 GRD-84 Test Code. D 3 VV-PRC008-EN

33 Diffusers Mechanical Specifications MODEL VLSD and VLRD Supply and Return Diffusers. LINR. General Casing This diffuser is constructed of 4-gage galvannealed steel. Hanger holes on each end of the diffuser for installation are optional. Slot edges formed over; provide double thickness tile support as an integral part of the diffuser housing. ll exposed surfaces are finished with white enamel.. Insulation The interior surface of the diffuser casing is acousticallyand thermally-lined with ½-inch (3 mm).9 lb cu ft (30.4 kgs/cu m), R-Value of. density glass fiber with high-density facing. The insulation is UL listed and meets NFP-90 and UL 8 standards. 3. T-Bar Ceiling This diffuser is designed to install over the T of most standard exposed suspended ceilings. The end angle is provided to allow the slot to fit flush with the bottom of the T and ceiling tile. 4. x T-Bar Ceiling This diffuser is designed to install over the T of most standard exposed suspended ceilings. The notch is provided in the middle of the unit to allow the diffuser to set over the T located at the middle point. 5. Concealed Spline Ceiling The diffuser is designed to sit in the center of the module, parallel to the main ceiling support member. The ceiling tile rests on the edge of the discharge slot and the flange. t-bar insert is provided in the center of a two-way throw diffuser, when applicable. 6. Plaster Ceiling The diffuser is designed to sit into the opening in the plaster. The diffuser must be used in conjunction with a trim frame for a finished appearance. 7. Trim Frame The trim frame is extruded aluminum and designed to attach to the diffuser slot(s) with clips. The trim frame is finished with white enamel and is designed to set into the opening of a plaster ceiling for a finished appearance. 8. Fire Damper n integral fusible link, -gage factory installed fire damper. The fusible link has a melting point of 58 F (70 C). 9. Inlet Balancing Damper factory-provided and -installed single-blade damper, with a position-locating handle for balancing air. 0. Inlet The inlet connection is sized to fit standard, round, flexible ductwork.. gency Listing UL listed as environmental air terminal unit. Control #49X (- and -slot only). FPF, VPF, VPS, BD. General Casing This diffuser is constructed of 4-gage galvannealed steel. ll exposed surfaces of the diffuser are finished with flat black enamel. Factoryinstalled t-bars are finished with white enamel.. Insulation The interior surface of the supply diffuser casing is acoustically- and thermally-lined with ½-inch (3 mm).9 lb/cu ft (30.4 kg/cu m), R-Value of. density glass fiber with highdensity facing. The insulation is UL listed and meets NFP-90 and UL 8 standards. 3. T-Bar Ceiling This diffuser is designed to install over the T of most standard exposed suspended ceilings. The end angle is provided to allow the slot to fit flush with the bottom of the T and ceiling tile. 4. x T-Bar Ceiling This diffuser is designed to install over the T of most standard exposed suspended ceilings. The notch is provided in the middle of the unit to allow the diffuser to set over the T located at the middle point. 5. Plaster Ceiling The diffuser is designed to set into the opening in the plaster. The diffuser must be used in conjunction with a trim frame for a finished appearance. The trim frame is extruded aluminum with white finish. 6. Inlet Balancing Damper factory-provided and -installed single-blade damper, with a position-locating handle for balancing air. 7. Inlet The inlet connection is sized to fit standard, round, flexible ductwork. INDT. General Casing This diffuser is constructed of 4-gage galvannealed steel. Exposed surfaces are finished with flat black enamel.. Insulation The interior surface of the diffuser casing is acousticallyand thermally-lined with ½-inch (3 mm).9 lb cu ft (30.4 kgs/cu m), R-Value of. density glass fiber with high-density facing. The insulation is UL listed and meets NFP-90 and UL 8 standards. 3. T-Bar Ceiling This diffuser is designed to install over the T of most standard exposed suspended ceilings. 4. x T-Bar Ceiling This diffuser is designed to install over the T of most standard exposed suspended ceilings. The notch is provided in the middle of the unit to allow the diffuser to set over the T located at the middle point. 5. Plaster Ceiling The diffuser is designed to set into the opening in the plaster. The diffuser must be used in conjunction with a trim frame, for a finished appearance. The trim frame is extruded aluminum and designed to attach to the diffuser slot with clips. The trim frame is finished with white enamel. 6. Inlet Balancing Damper factory-provided and -installed single-blade damper, with a position-locating handle for balancing air. 7. Inlet The inlet connection is sized to fit standard, round, flexible ductwork. LITE. General Casing This diffuser is constructed of 4-gage galvannealed steel. Hold-down tabs on the diffuser ends are provided to align and lock the diffuser to the light air slot. Exposed slot area is painted flat black.. Insulation Optional. If used, the interior surface of the diffuser casing is acoustically and thermally lined with ½ inch (3 mm).9 lb cu ft (30.4 kgs/cu m), R-Value of. density glass fiber with highdensity facing. The insulation is UL listed and meets NFP-90 and UL 8 standards. The external insulation is foil-faced. 3. Dual Side Diffuser This diffuser is designed for dual-side installation on the light fixture. 4. Single Side Diffuser This diffuser is designed for single-side installation on the light fixture. side bracket is provided for extra support. 5. Inlet The inlet connection is sized to fit standard, round, flexible ductwork. VV-PRC008-EN D 33

Square/Rect. and Square Louvered Face and Plaque Face Diffuser

Square/Rect. and Square Louvered Face and Plaque Face Diffuser /Rect. and Louvered Face and Plaque Face Diffuser Series J: Easily Adjustable from Horizontal to Vertical Vertical Discharge Application: Carnes steel (SK) and aluminum (SE) louvered face diffusers are

More information

MODULAR CORE CEILING DIFFUSERS

MODULAR CORE CEILING DIFFUSERS MOEL SQUARE 12345-10 MOULAR CORE SQUARE IFFUSERS ROUN NECK SQUARE 1, 2, 3 OR ROUN 4-WAY AJUSTABLE NECK SQUARE ISCHARGE ROUN PATTERN NECK Steel Model: 7500 Suffix '-O' adds a steel opposed blade damper

More information

FIRE RATED PRODUCTS FIRE RATED PRODUCTS

FIRE RATED PRODUCTS FIRE RATED PRODUCTS IRE RTED PRODUCTS IRE RTED DUCTLESS RETURN ILTER GRILLES Model Series 4100 Ductless Return ir ilter Grilles have been designed to compliment the Nailor range of fire rated supply diffusers. These grilles

More information

Optima EXHAUST GRILL AND AIR LOUVER. Perforated Ceiling Diffusers. Features: Standard square sizes:

Optima EXHAUST GRILL AND AIR LOUVER. Perforated Ceiling Diffusers. Features: Standard square sizes: Perforated Ceiling Diffusers OPTIMA ceiling diffuser with perforated face, are recoended for heating, ventilating and cooling in centralized air conditioning systems. Perforated face diffusers, with 4-3-

More information

SINGLE DUCT TERMINAL UNITS 30X/HQX SERIES

SINGLE DUCT TERMINAL UNITS 30X/HQX SERIES 30X/HQX SERIES 30X SERIES EXHUST 30HQX SERIES EXHUST HOSPITL GRDE QUIET TYPE WITH DISSIPTIVE SILENCER PRODUCT OVERVIEW Nailor Single Duct Exhaust Terminal Units are used to modulate exhaust flow from an

More information

B1-2. Table of Contents LOUVERED FACE DIFFUSERS

B1-2. Table of Contents LOUVERED FACE DIFFUSERS Table of Contents 2, FR,, M & M feature a round neck and four cones. & feature a round neck, four cones, and adjustable pattern controllers.,, M, & M feature a round neck and three cones. & feature a round

More information

DRUM LOUVERS DRUM LOUVERS 45DL SERIES. Models: 45DL1 Single Vanes 45DL2 Split Vanes G151 HIGH CAPACITY LONG THROW ALUMINUM CONSTRUCTION

DRUM LOUVERS DRUM LOUVERS 45DL SERIES. Models: 45DL1 Single Vanes 45DL2 Split Vanes G151 HIGH CAPACITY LONG THROW ALUMINUM CONSTRUCTION DRUM LOUVERS 45DL SERIES HIH CAPACITY LON THROW ALUMINUM CONSTRUCTION Models: Single Vanes 45DL2 Split Vanes Suffix '-O' adds a steel opposed blade damper Models -O and 45DL2 Model Series 45DL Drum Louvers

More information

SPD SQUARE PLAQUE DIFFUSER

SPD SQUARE PLAQUE DIFFUSER SQUARE PLAQUE DIFFUSER The (SPD) has a flush appearance, making it ideal for architecturally-conscience commercial spaces, and provides industry-leading low pressure drop and sound generation with a 360

More information

CUSTOM FLOW ARCHITECTURAL SLOT DIFFUSER

CUSTOM FLOW ARCHITECTURAL SLOT DIFFUSER ARCHITECTURAL SLOT DIFFUSER Custom Flow (CF) slot diffusers are uniquely designed for curving and long continuous installations. The CF offers a large range of airflow flexibility with one or two slot

More information

STEEL LOUVERED DIFFUSERS [CFM Range is only a guide. See Manufacturer Catalog for complete data. All NC Levels in Acceptable Range<32.

STEEL LOUVERED DIFFUSERS [CFM Range is only a guide. See Manufacturer Catalog for complete data. All NC Levels in Acceptable Range<32. STEEL LOUVERED DIFFUSERS TUTTLE & BAILEY Model 1300 - Round Neck Steel, Lay-In Tee Bar Mounting Neck Size Panel Size CFM Range Price Each Volume Damper Model RBN *6 12 x 12 75-180 $19 $12 6 24 x 24 75-180

More information

CEILING DIFFUSERS Previous View Home Contents Dimensions Specification Performance

CEILING DIFFUSERS Previous View Home Contents Dimensions Specification Performance 1 Contents Page No. General Product Overview 5 Exclusive Steel Grille, Register and iffuser Warranty 12 Square and Rectangular Pattern Ceiling iffusers 6500 - Steel - Fixed Pattern 13 6550 - Steel - djustable

More information

LINEAR DIFFUSERS AND BAR GRILLES

LINEAR DIFFUSERS AND BAR GRILLES 49-240 48LL1 49-280 49-480 48LL2 Linear ar Grilles The Nailor 4900 Series provides an extruded aluminum bar grille that offers beautiful styling and efficient performance. Linear bar grilles offer a choice

More information

EGG CRATE RETURN GRILLE

EGG CRATE RETURN GRILLE 80 EGG CRATE RETURN GRILLE 80 The 80 Series is available in various mounting styles and features sturdy construction, consisting of a heavy gauge aluminum grid core, optional extruded aluminum borders

More information

Total comfort control

Total comfort control Total comfort control YORK ACTIVE CHILLED BEAM WITH PERFORATED RETURN DIFFUSER Table of contents Concept & Technology Air Distribution & Facade Orientation Product Features Dimensions Performance Data

More information

LINEAR SLOT DIFFUSERS PLENUMS

LINEAR SLOT DIFFUSERS PLENUMS LINEAR SLOT DIFFUSER PLENUMS ADAPTORS FOR MODEL SERIES 5000 LINEAR SLOT CEILING DIFFUSERS Standard Models: 5350(I) 1/2" (13) Slot 5375(I) 3/4" (19) Slot 5310(I) 1" (25) Slot Modified Performance Models:

More information

LINEAR DIFFUSERS AND BAR GRILLES

LINEAR DIFFUSERS AND BAR GRILLES LINEAR DIFFUSERS AND AR GRILLES LINEAR DIFFUSERS AND AR GRILLES LINEAR SLOT DIFFUSER PLENUMS FOR TECHZONE TYPE CEILINGS Model Series 5300TZ Plenums are designed to fit the 5000TZ Series Slot Diffusers.

More information

SERIES GB. Adjustable Slot Swirl Diffusers

SERIES GB. Adjustable Slot Swirl Diffusers SERIES G djustable Slot Swirl Diffusers PULICTION DIFFUSERS 14 OCTOER 2014 Features - Distinctive slotted architectural design - Individually adjustable slots - 4 Swirl Pattern options - Versatile Directional

More information

PERFORATED CEILING DIFFUSERS

PERFORATED CEILING DIFFUSERS PERFORAE PERFORAE CURVE MOEL BLAE 12345-10 IFFUSERS SQUARE ROUN NECK SQUARE SUPPLYROUN NECK 4-WAY AJUSABLE ISCHARGE SQUARE ROUN NECK PAERN (SANAR) 1, 2 OR 3-WAY ISCHARGE PAERN (OPIONAL) Steel Models: 4320CB

More information

PERFORATED CEILING DIFFUSERS

PERFORATED CEILING DIFFUSERS PERFORAE MOEL PERFORAE 12345-10 CEILING SQUARE IFFUSERS ROUN NECK SQUARE ROUN NECK SUPPLY SQUARE 1, 2, 3 OR ROUN 4-WAY AJUSABLE NECK ISCHARGE PAERN Steel Models: 4320 Flush Face 4325 rop Face Aluminum

More information

KLIMA Active Chilled Beams

KLIMA Active Chilled Beams KLIMA 2 600 Active Chilled Beams 0 Index Subject Page Index 1 Introduction 2 General description 3-4 Product features 5-6 Dimensions 7 Performance data 8-11 Selection example 12 Guide specifications 13

More information

K1-2. Table of Contents LINEAR BAR GRILLES 1500, 1500MC, 1800, 1800MC

K1-2. Table of Contents LINEAR BAR GRILLES 1500, 1500MC, 1800, 1800MC K Table of Contents, This series of extruded aluminum supply and return linear bar grilles are for ceiling, sidewall, sill (), and floor () applications. Blade thickness is 7/32., This series of extruded

More information

LAMINAR FLOW DIFFUSER Model DLAB

LAMINAR FLOW DIFFUSER Model DLAB Laminar & Radial Flow Diffuser LAMINAR FLOW DIFFUSER Model DLAB Application Laminar Flow diffusers are used to deliver air to surface directly underneath in a non-aspirating air pattern, with the minimum

More information

CEILING DIFFUSERS CEILING DIFFUSERS

CEILING DIFFUSERS CEILING DIFFUSERS Model 4340M Model 4330CB Premium, Curved Blade Pattern Controllers The perforated diffusers in this series have an extruded aluminum frame with a narrow border that is visible within the T-Bar module.

More information

RPD ROUND PLAQUE DIFFUSER

RPD ROUND PLAQUE DIFFUSER ROUND PLAQUE DIFFUSER s (RPD) provide a balance between engineering and architectural needs, with a flush appearance and superior VAV performance in both ceiling and exposed duct mounting applications.

More information

D1-2. Table of Contents MODULAR CORE DIFFUSERS. 1240, Introduction & Product Description... D1-3. Dimensional Information...

D1-2. Table of Contents MODULAR CORE DIFFUSERS. 1240, Introduction & Product Description... D1-3. Dimensional Information... D Table of Contents, These supply, ceiling diffusers feature four handremovable modular cores. Available in steel or aluminum construction. P, P These supply, ceiling diffusers feature four handremovable

More information

HORD HOSPITAL OPERATING ROOM AIR CURTAIN

HORD HOSPITAL OPERATING ROOM AIR CURTAIN HORD HOSPITAL OPERATING ROOM AIR CURTAIN The Hospital Operating Room Diffuser (HORD) air curtain system is engineered specifically for the demanding needs of operating room environments. The HORD air curtain

More information

6490, These perforated. ceiling returns feature a. square neck. Aluminum or steel perforated face. is available. 6600, 56600, 6600FR

6490, These perforated. ceiling returns feature a. square neck. Aluminum or steel perforated face. is available. 6600, 56600, 6600FR C Table of Contents 6, 6 6, 6 supply ceiling diffusers feature a neck mounted rotatable core with either a round or square neck. Aluminum or steel perforated face is available. 62, 62 62FR, 629F supply,

More information

Product Data. Features/Benefits. 35K Bypass Terminal. 110 to 4400 cfm

Product Data. Features/Benefits. 35K Bypass Terminal. 110 to 4400 cfm Product Data 35K Bypass Terminal 110 to 4400 cfm Carrier s 35K Series bypass terminals offer: 20-gage, galvanized steel casing construction 1/2-in. thick, dual density fiberglass insulation meeting NFPA

More information

FlowBar High Capacity Slot Diffuser

FlowBar High Capacity Slot Diffuser October 2016 FlowBar High Capacity Diffuser Model HT (High Throw) Model JT (Jet Throw) Features HT & JT 25mm, 38mm, 51mm, 63mm & 76mm s Ceiling or Sidewall Applications Modular or Continuous s Curved Sections

More information

PE-5000 DUCT STATIC PRESSURE SENSING ELEMENT

PE-5000 DUCT STATIC PRESSURE SENSING ELEMENT Technical Data Sheet PE-5000 DUCT STTIC PRESSURE SENSING ELEMENT DESCRIPTION Model PE-5000 units are insertion-type primary duct pressure sensing elements designed to achieve pressure signal accuracy and

More information

CEILING DIFFUSERS D12 CEILING DIFFUSERS

CEILING DIFFUSERS D12 CEILING DIFFUSERS PREMIUM This perforated return has an extruded aluminum frame with a narrow border that is visible within the T-Bar module. See Model Series 4330 and 4330CB for the matching supply air diffusers. Flush

More information

LOUVERED FACE GRILLES AND REGISTERS

LOUVERED FACE GRILLES AND REGISTERS Performance Notes for Supply rilles and Registers, 6 and 67 Series Throw, Spread and Drop The isovel diagrams shown below, illustrate in plan view, the relationship of horizontal spread to throw for three

More information

Application Guidelines

Application Guidelines Grilles and Registers Application Guidelines Introduction Overview It is the intent of this section to give some basic application guidelines for the use of supply and return grilles and registers in a

More information

FE-1000 INSERTION TYPE AIRFLOW SENSING ELEMENT

FE-1000 INSERTION TYPE AIRFLOW SENSING ELEMENT Technical Data Sheet FE-1000 INSERTION TYPE IR SENSING ELEMENT DESCRIPTION The FE-1000 is an insertion type airflow sensing element designed for quick, easy installation through a small cutout in the existing

More information

Donn. Air Diffuser. Technical Data. plenum. diffuser frame. Features

Donn. Air Diffuser. Technical Data. plenum. diffuser frame. Features Technical Data Donn Features The DONN brand air diffuser provides air delivery and return for the ceiling system. Air is supplied through the lay-in diffuser, which is placed on the 2 x 2, narrow-suspension

More information

GRILLES AND REGISTERS

GRILLES AND REGISTERS Airfoil Blade Return Air Models 71FH, 7145H 45 Deflection, 3/4" (19) Blade Spacing The airfoil blades are fixed at a 45 angle. This grille is vision proof when installed in a low or high sidewall location

More information

B1-2. Table of Contents LOUVERED FACE DIFFUSERS

B1-2. Table of Contents LOUVERED FACE DIFFUSERS B1 LOUEED FACE DIFFUE Table of Contents LOUEED FACE DIFFUE B12 1400, 1400F, 1400, M1400 & M1400 feature a round neck and four cones. 1400A & 1400A feature a round neck, four cones, and adjustable pattern

More information

500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT FORM EG3 (404)

500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT FORM EG3 (404) 500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT Table of Contents Introduction...3 500-YVI Features...4-5 Dimensional Data...6-7 ARI Rating Points...8 Statement of Standard Test Conformity...8 Motor Amperage

More information

Diffusers. Comfort for Any Business Situation

Diffusers. Comfort for Any Business Situation Diffusers Comfort for Any Business Situation The Right Diffuser Is the One You Never Notice knows that you have more than one goal in mind when you select air diffusers for your office building. Blending

More information

ATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT Metal Industries, Inc.

ATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT Metal Industries, Inc. ATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT 15 Metal Industries, Inc. BENEFITS: Fan powered terminals are typically used for heating and cooling of perimeter zones.

More information

CONCENTRIC Product Information & Applications

CONCENTRIC Product Information & Applications CONCENTRIC Product Information & pplications Concentrics s the leading manufacturer of Concentric Diffusers for the past 30 years, Ruskin Rooftop Systems offers a cost effective way of distributing air

More information

GRILLES AND REGISTERS

GRILLES AND REGISTERS RILLES AND REISTERS Models 45DL1, 45DL2 Models 813SH-O, 813DV Drum Louvers These extruded aluminum drum louvers are appropriate when high volumes of air are used and in spot heating and cooling applications.

More information

PATTERN CEILING DIFFUSERS

PATTERN CEILING DIFFUSERS PATTERN CEILING IFFUSERS Model 4260 Model 7500 Eggcrate Return This aluminum face return diffuser features 1/2" x 1/2" x 1/2" (13 x 13 x 13) eggcrate that provides a high free area. It is offered with

More information

Catalogue. FlowBar. High Capacity Slot Diffuser.

Catalogue. FlowBar. High Capacity Slot Diffuser. Catalogue FlowBar High Capacity Slot Diffuser www.air-diffusion.co.uk sales@air-diffusion.co.uk Content Introduction... 4 Diffuser Specification... 5 Air Patterns... 6 Flange Styles... 7 Curved Sections...

More information

SINGLE DUCT TERMINAL UNITS 3000 SERIES

SINGLE DUCT TERMINAL UNITS 3000 SERIES 000 SERIES 000 SERIES VRIBLE OR CONSTNT VOLUME PRODUCT OVERVIE Nailor 000 Series Single Duct Terminal units are simply put, versatile. hether the requirement calls for a constant or variable air volume

More information

CEILING DIFFUSERS GENERAL PRODUCT OVERVIEW

CEILING DIFFUSERS GENERAL PRODUCT OVERVIEW CEILING IFFUSERS CEILING IFFUSERS GENERAL PROUCT OVERVIEW Ceiling iffusers Quality Assured Products, unobtrusive clean lines for appearance, careful engineering and professional workmanship with the backing

More information

CEILING DIFFUSERS GENERAL PRODUCT OVERVIEW

CEILING DIFFUSERS GENERAL PRODUCT OVERVIEW GENERAL PROUCT OVERVIEW Ceiling iffusers Quality Assured Products, unobtrusive clean lines for appearance, careful engineering and professional workmanship with the backing of an industry leader - these

More information

CEILING DIFFUSERS GENERAL PRODUCT OVERVIEW

CEILING DIFFUSERS GENERAL PRODUCT OVERVIEW GENERAL PROUCT OVERVIEW Ceiling iffusers Quality Assured Products, unobtrusive clean lines for appearance, careful engineering and professional workmanship with the backing of an industry leader - these

More information

HORD HOSPITAL OPERATING ROOM AIR CURTAIN

HORD HOSPITAL OPERATING ROOM AIR CURTAIN HORD HOSPITAL OPERATING ROOM AIR CURTAIN The Hospital Operating Room Diffuser (HORD) air curtain system is engineered specifically for the demanding needs of operating room environments. The HORD air curtain

More information

SERIES DG. Louvred Face Ceiling Diffusers

SERIES DG. Louvred Face Ceiling Diffusers SERIES DG Louvred Face Ceiling Diffusers PUBLICTION DIFFUSERS 1 JULY Features - ttractive Louvred Face Design. - 4 Frame/Border Styles. - 9 Different ir Pattern Core Options. - Spring Loaded Removable

More information

INDOOR ENVIRONMENTAL SOLUTIONS

INDOOR ENVIRONMENTAL SOLUTIONS Specifications & Engineering Guide INDOOR ENVIRONMENTAL SOLUTIONS Introduction New High Performance Diffuser Technology Warren Technology has developed a new, technological breakthrough in air distribution

More information

DONN Brand Air Diffuser

DONN Brand Air Diffuser Technical Data DONN Brand Air Diffuser Features The DONN Brand air diffuser provides air delivery and return for the ceiling system. Air is supplied through the lay-in diffuser which is placed on the 2

More information

CEILING DIFFUSERS CEILING DIFFUSERS

CEILING DIFFUSERS CEILING DIFFUSERS CEILING IFFUSERS "TWISTER" HIGH INUCTION STAMPE FACE The "Twister" diffuser is engineered to optimize air distribution effectiveness. This next generation diffuser has a high induction, 360 swirl pattern

More information

6490, These perforated. ceiling returns feature a. square neck. Aluminum or steel perforated face. is available. 6600, 56600, 6600FR

6490, These perforated. ceiling returns feature a. square neck. Aluminum or steel perforated face. is available. 6600, 56600, 6600FR C1 Table of Contents 1, 15 51, 515 supply ceiling diffusers feature a neck mounted rotatable core with either a round or square neck. Aluminum or steel perforated face is available. 2, 52 2FR, 2F supply,

More information

CEILING DIFFUSERS CEILING DIFFUSERS

CEILING DIFFUSERS CEILING DIFFUSERS CEILING IFFUSERS "TWISTER" HIGH INUCTION STAMPE FACE The "Twister" diffuser is engineered to optimize air distribution effectiveness. This next generation diffuser has a high induction, 360 swirl pattern

More information

Application Guidelines

Application Guidelines Grilles and Registers Application Guidelines Introduction Overview It is the intent of this section to give some basic application guidelines for the use of supply and return grilles and registers in a

More information

Slot diffusers for ceiling installation

Slot diffusers for ceiling installation X X testregistrierung Slot diffusers for ceiling installation Type lenum box with damper blade (optional) Alternating horizontal air discharge Concealed screw fixing With wide diffuser face for larger

More information

Concentric Supply/Return Diffusers. Models CSR & CSR-P. Redefine your comfort zone.

Concentric Supply/Return Diffusers. Models CSR & CSR-P. Redefine your comfort zone. Concentric Supply/Return Diffusers Models CSR & CSR-P Redefine your comfort zone. www.titus-hvac.com Concentric Supply/Return Diffusers Models CSR & CSR-P Plenum CSR Rectangular Ceiling Diffuser Combination

More information

OVERVIEW Combination Supply/Return Diffuser (SARM)

OVERVIEW Combination Supply/Return Diffuser (SARM) OVERVIEW Combination Supply/Return Diffuser (SARM) APPLICATION INFORMATION The extruded aluminum square and rectangular supply and return diffusers are designed principally for packaged roof top type heating

More information

CEILING DIFFUSERS CEILING DIFFUSERS

CEILING DIFFUSERS CEILING DIFFUSERS "TWISTER" HIGH INUCTION STAMPE FACE The "Twister" diffuser is engineered to optimize air distribution effectiveness. This next generation diffuser has a high induction, 360 swirl pattern for a superior

More information

W-VI Series - Internal Make-up Air Wall Canopy

W-VI Series - Internal Make-up Air Wall Canopy W-VI Internal Make-up ir Wall Canopy With Diffuser W-VI single shell combination internal make-up air/air curtain canopy constructed of stainless steel where visible and aluminized steel where concealed.

More information

Fan-Powered Parallel

Fan-Powered Parallel Table of Contents Model Number Description 76 Selection Procedure 77-79 General Data Setting Guidelines 80 Performance Data Pressure Requirements 81 Performance Data Fan Curves 82-85 Performance Data Hot

More information

B1-2. Table of Contents LOUVERED FACE DIFFUSERS

B1-2. Table of Contents LOUVERED FACE DIFFUSERS 1 LOUVERED FACE DIFFUER Table of Contents LOUVERED FACE DIFFUER 12 1400, 1400FR, 1400, M1400 & M1400 These supply diffusers feature a round neck and four cones. 1400A & 1400A These supply diffusers feature

More information

500-YCI SERIES FAN-POWERED AIR TERMINAL UNIT FORM EG2 (404)

500-YCI SERIES FAN-POWERED AIR TERMINAL UNIT FORM EG2 (404) 500-YCI SERIES FAN-POWERED AIR TERMINAL UNIT Table of Contents General Information...3 500-YCI Features...4-5 Dimensional Data...6-7 ARI Rating Points...8 Statement of Standard Test Conformity...8 Motor

More information

FAN POWERED TERMINAL UNITS

FAN POWERED TERMINAL UNITS Benefits: Fan powered terminals are typically used for heating and cooling of perimeter zones. Operating cost savings can be achieved through the use of waste heat recovery from the ceiling plenum and

More information

SERIES GD. Square and Circular Fixed Swirl Diffusers

SERIES GD. Square and Circular Fixed Swirl Diffusers SERIES G Square and ircular Fixed Swirl iffusers PULITION IFFUSERS 18 MY 2018 Features - istinctive architecturally appealing designs - Two swirl pattern options - order styles compatible with modern ceiling

More information

GRILLES AND REGISTERS

GRILLES AND REGISTERS Heavy Duty Steel rilles and Registers, ymnasium Strength Nailor s Heavy Duty Steel rilles and Registers are manufactured with 16 gauge steel frames and 14 gauge steel blades which gives them strength to

More information

Model ND-2 Specification

Model ND-2 Specification Model ND-2 Specification The model ND-2 is an exhaust only canopy hood rated for all types of cooking equipment. The hood shall have the size, shape and performance specified on drawings. Construction

More information

2/6.1/EN/1. High Induction. Variable / Constant Volume Swirl Diffuser Types HIVV HICV

2/6.1/EN/1. High Induction. Variable / Constant Volume Swirl Diffuser Types HIVV HICV 2/6.1/EN/1 High Induction Variable / Constant Volume Swirl Diffuser Types HIVV HICV Contents Description Description... Specification Dimensions... HIVV-E Operation... Quick Selection Table... Technical

More information

Product Data. Features/Benefits. WEATHERMASTER 36S Water Control Induction Air Terminals to cfm (1770 to 8900 Btuh)

Product Data. Features/Benefits. WEATHERMASTER 36S Water Control Induction Air Terminals to cfm (1770 to 8900 Btuh) Product Data WEATHERMASTER 36S Water Control Induction Air Terminals 19.4 to 131.9 cfm (1770 to 8900 Btuh) Induction air terminals offer: Heating and cooling operation 2-pipe or 4-pipe system options Automatic

More information

4880 This heavy duty, double deflection, supply grille features 1/2 front and 3/4 back blade. spacing. Available in steel construction only.

4880 This heavy duty, double deflection, supply grille features 1/2 front and 3/4 back blade. spacing. Available in steel construction only. I1I Table of Contents 1/51 1M/51M These supply grilles feature individually adjustable curved blades. Available in steel or aluminum construction. /5 These single deflection supply grilles feature 3/ blade

More information

fsfdfsdfsdfssfsf OMNI DIFFUSER

fsfdfsdfsdfssfsf OMNI DIFFUSER fsfdfsdfsdfssfsf OMNI DIFFUSER Architectural Ceiling Diffusers diffusers OMNI The Titus OMNI diffuser satisfies architectural as well as engineering criteria. Its strong, clean, unobtrusive lines harmonize

More information

CEILING DIFFUSERS CEILING DIFFUSERS. Aluminum Construction Model 6300R See Page D135. Fully Adjustable Horizontal/Vertical Pattern

CEILING DIFFUSERS CEILING DIFFUSERS. Aluminum Construction Model 6300R See Page D135. Fully Adjustable Horizontal/Vertical Pattern 6 Model TWR "Twister" High Induction Stamped Face The "Twister" diffuser is engineered to optimize air distribution effectiveness. This next generation diffuser has a high induction, 360 swirl pattern

More information

C O L M A N. Air Distribution PERFORATED FACE DIFFUSERS P SERIES SERIES

C O L M A N. Air Distribution PERFORATED FACE DIFFUSERS P SERIES SERIES C O L M A N Air Distribution E N G I N E E R E D A I R P R O D U C T S PERFORATED FACE DIFFUSERS P SERIES P SERIES PERFORATED FACE DIFFUSERS P SERIES QUALITY AND EFFICIENCY WITHOUT COMPROMISE Application:

More information

HORD INSTALLATION & SERVICE MANUAL. Hospital Operating Room Diffusers INSTALLATION & SERVICE MANUAL. Date: 06 / 12 Reference # : E-10 1

HORD INSTALLATION & SERVICE MANUAL. Hospital Operating Room Diffusers INSTALLATION & SERVICE MANUAL. Date: 06 / 12 Reference # : E-10 1 HORD Hospital Operating Room Diffusers Date: 06 / 12 Reference # : E-10 1 2 Table of Contents Prior to Installation... 4 Ductwork Layout... 4 Installation of HORD Air Curtain System...5-9 T-Bar Ceiling...5-6

More information

CEILING DIFFUSERS. Supply Air

CEILING DIFFUSERS. Supply Air Perforated Ceiling iffusers Nailor manufactures a full range of supply air and matching return air Perforated Ceiling iffusers. he perforated face is available in both corrosion-resistant steel and aluminum,

More information

MODELS GED/GSD, DFE/DFS, DDE/DDS DIRECT DRIVE SIDEWALL PROPELLER FANS WALL HOUSING MOUNTING OPTIONS WALL HOUSING

MODELS GED/GSD, DFE/DFS, DDE/DDS DIRECT DRIVE SIDEWALL PROPELLER FANS WALL HOUSING MOUNTING OPTIONS WALL HOUSING DIRECT DRIVE SIDEWLL PROPELLER FNS WLL HOUSING MOUNTING OPTIONS WLL HOUSING: This heavy-gauge, all galvanized G-90 steel (aluminum optional) housing provides a simple solution to installing a fan and all

More information

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CD SERIES SERIES

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CD SERIES SERIES C O L M A N Air Distribution E N G I N E E R E D A I R P R O D U C T S LINEAR SLOT DIFFUSERS CD SERIES CD SERIES LINEAR SLOT DIFFUSERS QUALITY AND EFFICIENCY WITHOUT COMPROMISE Application Colman Moducel

More information

series KFD-KLD Linear slot diffusers

series KFD-KLD Linear slot diffusers series KFD-KLD Linear slot diffusers www.koolair.com KFD-KLD Contents Linear slot diffusers KFD Selection tables KFD Dimensions 6 Connection system Linear slot diffusers KLD 8 Selection tables KLD 0 Dimensions

More information

LINEAR DIFFUSERS AND BAR GRILLES

LINEAR DIFFUSERS AND BAR GRILLES LINEAR DIFFUSERS AND AR GRILLES GENERAL PRODUCT OVERVIEW Linear Diffusers and ar Grilles Linear type diffusers and grilles have been developed to satisfy architectural and engineering applications that

More information

ISSUE B, OCT Architectural Square Ceiling Diffusers. UNI & AUNI Diffusers. Advanced Air

ISSUE B, OCT Architectural Square Ceiling Diffusers. UNI & AUNI Diffusers. Advanced Air ISSUE B, OCT 2009 Architectural Square Ceiling Diffusers UNI & AUNI Diffusers Product Overview - Uni Series Architectural Ceiling Diffusers Uni Series High Performance Square Face Round Neck The Model

More information

Extruded Aluminum Construction 1/4 Bars on 1/2 Centers Floor, Sidewall or Ceiling Mount Pencil Proof

Extruded Aluminum Construction 1/4 Bars on 1/2 Centers Floor, Sidewall or Ceiling Mount Pencil Proof OVERVIEW Linear Bar, Grilles and Registers OVERVIEW LINEAR BAR, GRILLES and REGISTERS Curtainaire Trimaire Varicore Extruded Aluminum Construction 1/4 Bars on 1/2 Centers Floor, Sidewall or Ceiling Mount

More information

Linear Slot Diffusers Model Slot 20 & Model Slot 25

Linear Slot Diffusers Model Slot 20 & Model Slot 25 Model Slot & Model Slot 25 Contents Introduction!!!!!! Page 3 Di"user Specification!!!! Page 4 Air Patterns!!!!!! Page 5 Flange Styles!!!!!! Page 6 Corner Sections!!!!! Page 7 Selection Procedure!!!! Page

More information

HIGH CAPACITY LINEAR SLOT DUFFUSERS

HIGH CAPACITY LINEAR SLOT DUFFUSERS HIGH CAPACITY LINEAR SLOT DUFFUSERS CB SERIES Quality and efficiency without compromise Weltech Business Centre - Ridgeway - Welwyn Garden City - Hertfordshire AL7 2AA Tel: 01707 871526 - Fax: 01707 871

More information

PSTI High Induction Diffuser

PSTI High Induction Diffuser PSTI High Induction Diffuser Barcol-ir is continuously aiming to optimize construction and quality for all equipment. Barcol-ir has the right to adjust the product specifications without any obligation

More information

Redefine your comfort zone. chilled beams. energy solutions

Redefine your comfort zone.   chilled beams. energy solutions integrated lighting u open ceiling k-12 education wood grains dual-function energy solutions Table of Contents CHILLED BEAM PRODCTS Chilled Beam Products...3 Overview...6 ACTIVE CHILLED BEAMS CBAL-24 /

More information

Ceiling swirl diffusers with perforated face plate

Ceiling swirl diffusers with perforated face plate X X testregistrierung Ceiling swirl diffusers with perforated face plate Type Horizontal swirling air discharge Diffuser face plate with perforated circular face style and exposed discharge nozzle Diffuser

More information

Performance Information Series PVP 100/140 Pressure Compensated, Variable Volume, Piston Pumps

Performance Information Series PVP 100/140 Pressure Compensated, Variable Volume, Piston Pumps Catalog HY13-155-2/US Technical Information Series PVP 1/14 Performance Information Series PVP 1/14 Compensated, Variable Volume, Piston Pumps Features High Strength Cast-Iron Housing for Reliability and

More information

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades X X testregistrierung Type Vertical air discharge Horizontal air discharge For large temperature differences in heating mode, high penetration of air, with adjustable air control blades Circular ceiling

More information

LINEAR SLOT DIFFUSERS

LINEAR SLOT DIFFUSERS LINEAR SLOT DIFFUSERS MODEL CD Weltech Business Centre - Ridgeway - Welwyn Garden City - Hertfordshire AL7 2AA Tel: 01707 871526 - Fax: 01707 871 527 - email sales@jprservices.co.uk - www.jprservices.co.uk

More information

MODELS GED/GSD, eged/egsd, DFE/DFS, DDE/DDS

MODELS GED/GSD, eged/egsd, DFE/DFS, DDE/DDS LINE OVERVIEW Jenco s Direct Drive Sidewall Propeller line is designed to exhaust or supply large volumes of air at relatively low static pressures. With 3 types of construction, the direct drive models

More information

C O L M A N. Air Distribution SWIRL DIFFUSERS DWT SERIES DWT SERIES

C O L M A N. Air Distribution SWIRL DIFFUSERS DWT SERIES DWT SERIES C O L M A N Air Distribution E N G I N E E R E D A I R P R O D U C T S SWIRL DIFFUSERS DWT SERIES DWT SERIES DISTRIBUTION PATTERNS & FIXING OPTIONS Application The DWT Series of swirl diffusers have been

More information

SERIES GZL. High Induction Linear Diffuser (Patented)

SERIES GZL. High Induction Linear Diffuser (Patented) SERIES GZL High Induction Linear Diffuser (Patented) PUBLICATION DIFFUSERS 9 APRIL 2012 Features - One or Two Slot Design. - High Induction Effect. - Unique Crossflow Jet Air Distribution. - Dynamic Modern

More information

F1-2. Table of Contents PLENUM SLOT DIFFUSERS PTBS. Introduction & Dimensional Information... F1-3. Accessories... F1-54. Reference Charts...

F1-2. Table of Contents PLENUM SLOT DIFFUSERS PTBS. Introduction & Dimensional Information... F1-3. Accessories... F1-54. Reference Charts... F1 LENUM LO DIFFUE able of ontents his plenum slot supply diffuser features an adjustable blade. lots: 1 to 4 lot Widths: ¾, 1, 1½ Introduction & Dimensional Information... F13 Accessories... F15 eference

More information

FAN POWERED TERMINAL UNITS

FAN POWERED TERMINAL UNITS Benefits: Fan powered terminals are typically used for heating and cooling of perimeter zones. Operating cost savings can be achieved through the use of waste heat recovery from the ceiling plenum and

More information

GRILLES AND REGISTERS

GRILLES AND REGISTERS Curved Spiral Duct rilles Nailor s unique curved spiral duct grille design offers an architecturally superior appearance and saves installation time and money by directly mounting to the duct. This eliminates

More information

ADJUSTABLE SLOT DIFFUSER TYPE: SE800

ADJUSTABLE SLOT DIFFUSER TYPE: SE800 TYPE: SE800 Installation dimensions Construction with hanger brackets Construction without hanger brackets D C Application 7 E A 0 7 E A 0 The slot diffuser, type SE800 is used for the supply of cooled

More information

Ceiling swirl diffusers

Ceiling swirl diffusers X X testregistrierung Ceiling swirl diffusers Type Horizontal swirling air discharge Adjustable blades Protective cage For high rooms, with adjustable air control blades Circular ceiling swirl diffusers,

More information

(click on page links below) General & Performance Data 1. Suggested Spec 3. Accessories 4

(click on page links below) General & Performance Data 1. Suggested Spec 3. Accessories 4 HAR Variable Air Volume Diffusers Contents: (click on page links below) General & Performance Data 1 Suggested Spec 3 Accessories 4 AUCKLAND ph 09 279 5250 fax 09 275 5637 sales@temperzone.co.nz WELLINGTON

More information

D3-2. Table of Contents DISPLACEMENT VENTILATION

D3-2. Table of Contents DISPLACEMENT VENTILATION D3 Table of Contents This rectangular unit is ideal for wall or ceiling installations. B The U-shaped 180 discharge pattern and high capacity is ideal for retail spaces, commercial, or lobbies. ENGINEERING

More information