W-VI Series - Internal Make-up Air Wall Canopy
|
|
- Charla Cannon
- 5 years ago
- Views:
Transcription
1 W-VI Internal Make-up ir Wall Canopy With Diffuser W-VI single shell combination internal make-up air/air curtain canopy constructed of stainless steel where visible and aluminized steel where concealed. ll external seams shall be fluid welded and all internal seams shall be sealed with a high temp. silicone caulk. The Make-up air grill shall be an extruded aluminum diffuser with 15 nonadjustable vanes spaced 1/2" apart. n integral air curtain shall be provided on front of canopy with diffusers same as make up air grill. The hood supply plenum shall be lined with 1" thick foil backed fiberglass insulation. The supply air shall pass through two perforated metal baffle plates to even out air flow. UL Listed fire damper shall be supplied in both supply collars. Canopy shall be listed to meet NSF and UL 710 Standards and constructed to meet NFP-96 requirements. Grease trough to be easily removable and slope to removable grease cup. STNDRD FETURES Full Length ir Curtain UL Listed luminum Grease Filters UL Listed Globe Lights 3" Rear ir Space Removable Grease Trough & Cup Exhaust & Supply Collars Installed Hanging rackets 1" Thick ir Plenum Insulation Stainless Steel Construction Where Visible Extruded luminum Interior Linear Diffuser Extruded luminum ir curtain Linear Diffuser UL Listed Fire and ir Volume Dampers in Supply Collar Surface Mounted Control Panel OPTIONS ll Stainless Steel Construction UL Listed Stainless Steel Grease Filters UL Listed Insulated Top, ack and/or Ends for Zero Clearance to Combustible 14" Utility Cabinet for Fire Suppression System Electrical Control Panel Pre-Plumbed Fire Suppression Stainless Steel Top Enclosures (See reverse side for larger drawing) 50", 56", 62", 68" W-VI Series - Internal Make-up ir Wall Canopy UILT IN CCORDNCE WITH NFP 96 Revised July 2001 Duo-ire
2 W-VI Series Specifications Project: ORDER ENTRY INFORMTION Item: 50", 56", 62", 68" Representative: Model: Length: Qty: FIRE & Width: Height: Duct - Concentric Parallel Exhaust CFM: Supply CFM: ir Curtain CFM: Entered by: Section Date: Drawings Req d: Y N EXHUST ND SUPPLY RTE REQUIREMENTS ( Recommended Min. TEMPERTURE OF EQUIPMENT Exhaust Flow Rate) CFM Exhaust / Ft CFM Supply / Ft CFM Supply.C./ Ft List Miscellaneous Options Separately Duo-ire reserves the right to make changes in design and specifications without prior notice.
3 I-VI Internal Make-up ir Island Canopy With Diffuser Model I-VI double shell internal make-up air canopy constructed of stainless steel where visible and aluminized steel where concealed. ll external seams shall be fluid welded and all internal seams shall be sealed with a high temp. silicone caulk. The Make-up air grill shall be an extruded aluminum diffuser with 15 nonadjustable vanes spaced 1/2" apart. n integral air curtain shall be provided on front of canopy with diffusers as make up air grill. The hood supply plenum shall be lined with 1" thick foil backed fiberglass insulation. The supply air shall pass through two perforated metal baffle plates to even out air flow. UL Listed fire damper shall be supplied in both supply collars. Canopy shall be listed to meet NSF and UL 710 Standards and constructed to meet NFP-96 requirements. Grease trough to be easily removable and slope to removable grease cup. STNDRD FETURES Full Length ir Curtain UL Listed luminum Grease Filters UL Listed Globe Lights Removable Grease Trough & Cup Exhaust & Supply Collars Installed Hanging rackets 1" Thick ir Plenum Insulation Stainless Steel Construction Where Visible Extruded luminum Interior Linear Diffuser Extruded luminum ir curtain Linear Diffuser UL Listed Fire and ir Volume Dampers in Supply Collar Flush Mounted Control Panel OPTIONS ll Stainless Steel Construction UL Listed Stainless Steel Grease Filters 14" Utility Cabinet for Fire Suppression System Electrical Control Panel Pre-Plumbed Fire Suppression Stainless Steel Top Enclosures UL Listed Insulated Top and/or Ends for Zero Clearance to Combustible (See reverse side for larger drawing) I-VI - Internal Make-up ir Island Canopy UILT IN CCORDNCE WITH NFP 96 Revised July 2001 Duo-ire
4 I-VI Series Specifications Project: ORDER ENTRY INFORMTION Item: Representative: 1/2 Model: 1/2 Length: Qty: Width: Height: FIRE & Duct - Concentric Parallel Exhaust CFM: Supply CFM: ir Curtain CFM: Entered by: Date: Section EXHUST ND SUPPLY RTE REQUIREMENTS ( Recommended Min. TEMPERTURE OF EQUIPMENT Exhaust Flow Rate) CFM Exhaust / Ft CFM Supply / Ft CFM Supply.C./ Ft Drawings Req d: Y N List Miscellaneous Options Separately Duo-ire reserves the right to make changes in design and specifications without prior notice.
5 ENGINEERING WORKSHEET W-VI SERIES 400 F. EQUIPMENT Length Exhaust Exhaust Duct Filter Filter Exhaust Supply Supply Supply Supply ir in Ft. CFM Collar Velocity rea Velocity Static CFM CFM Static Collar Curtain 300/Ft. X FPM Sq. Ft. FPM Pressure 10" Diff. 4" Diff. Pressure X Collar x x12 6x x x12 6x x x12 6x x x12 6x x x12 (2)6x x x12 (2)6x x x12 (2)6x x x12 (2)6x x x12 (3)6x (2)14 x (2)18x12 (3)6x (2)15 x (2)18x12 (3)6x (2)16 x (2)18x12 (3)6x (2)18 x (2)18x12 (3)6x12 W-VI SERIES 600 F. EQUIPMENT Length Exhaust Exhaust Duct Filter Filter Exhaust Supply Supply Supply Supply ir in Ft. CFM Collar Velocity rea Velocity Static CFM CFM Static Collar Curtain 350/Ft. X FPM Sq. Ft. FPM Pressure 10" Diff. 4" Diff. Pressure X Collar x x12 6x x x12 6x x x18 6x x x18 6x x x18 (2)6x x x24 (2)6x x x24 (2)6x x x24 (2)6x x x24 (3)6x (2)16 x (2)12x18 (3)6x (2)18 x (2)12x18 (3)6x (2)19 x (2)12x18 (3)6x (2)20 x (2)12x18 (3)6x12
6 ENGINEERING WORKSHEET I-VI SERIES 400 F. EQUIPMENT Length Exhaust Exhaust Duct Filter Filter Exhaust Supply Supply Supply Supply ir in Ft. CFM Collar Velocity rea Velocity Static CFM CFM Static Collar Curtain 600/Ft. X FPM Sq. Ft. FPM Pressure 10" Diff. 4" Diff. Pressure X Collar x (2)12x12 (2)6x x (2)12x12 (2)6x x (2)12x12 (2)6x x (2)18x12 (2)6x x (2)18x12 (4)6x x (2)18x12 (4)6x x (2)24x12 (4)6x x (2)24x12 (4)6x x (2)24x12 (6)6x (2)18 x (4)18x12 (6)6x (2)20 x (4)18x12 (6)6x (2)20x (4)18x12 (6)6x (2)20x (4)24x12 (6)6x12 I-VI SERIES 600 F. EQUIPMENT Length Exhaust Exhaust Duct Filter Filter Exhaust Supply Supply Supply Supply ir in Ft. CFM Collar Velocity rea Velocity Static CFM CFM Static Collar Curtain 700/Ft. X FPM Sq. Ft. FPM Pressure 10" Diff. 4" Diff. Pressure X Collar x (2)12x12 (2)6x x (2)12x12 (2)6x x (2)12x12 (2)6x x (2)18x12 (2)6x x (2)18x12 (4)6x x (2)18x12 (4)6x x (2)24x12 (4)6x x (2)24x12 (4)6x x (2)24x12 (6)6x (2)20 x (4)18x12 (6)6x (2)21 x (4)18x12 (6)6x (2)22 x (4)18x12 (6)6x (2)24 x (4)24x12 (6)6x12
DW Series - Exhaust Only Wall Canopy
DW Exhaust Only Wall Canopy Model DW A single shell non-compensating exhaust only wall hung canopy constructed of stainless steel where visible and aluminized steel in concealed locations. All external
More informationModel ND-2 Specification
Model ND-2 Specification The model ND-2 is an exhaust only canopy hood rated for all types of cooking equipment. The hood shall have the size, shape and performance specified on drawings. Construction
More informationHOOD ACCESSORIES HOOD ACCESSORIES HOOD ACCESSORIES
HOOD ACCESSORIES 58 59 VAPORPROOF RECESSED INCANDESCENT LIGHT FIXTURE VAPORPROOF LIGHT FIXTURES RECESSED INCANDESCENT LIGHT FIXTURE Specifications Cut-Out Mounting Diagram Socket: Side mounted porcelain
More informationInstallation, Operation and Maintenance Manual
Commercial Kitchen Hood Installation, Operation and Maintenance Manual www.fastkitchenhood.com General Information Prior to installing the stainless steel ventilation hood, the installing contractor should
More informationKVR Capture Jet. KVR- Capture Jet Round Island Hood with Perimeter Jets. Round Island Hood with Perimeter Jets
KVR Capture Jet Round Island Hood with Perimeter Jets The KVR Round Island Capture Jet hood with perimeter jets is a highly efficient kitchen ventilation hood that removes contaminated air and excess heat
More informationLINEAR DIFFUSERS AND BAR GRILLES
49-240 48LL1 49-280 49-480 48LL2 Linear ar Grilles The Nailor 4900 Series provides an extruded aluminum bar grille that offers beautiful styling and efficient performance. Linear bar grilles offer a choice
More informationMODELS GED/GSD, DFE/DFS, DDE/DDS DIRECT DRIVE SIDEWALL PROPELLER FANS WALL HOUSING MOUNTING OPTIONS WALL HOUSING
DIRECT DRIVE SIDEWLL PROPELLER FNS WLL HOUSING MOUNTING OPTIONS WLL HOUSING: This heavy-gauge, all galvanized G-90 steel (aluminum optional) housing provides a simple solution to installing a fan and all
More informationSINGLE DUCT TERMINAL UNITS 30X/HQX SERIES
30X/HQX SERIES 30X SERIES EXHUST 30HQX SERIES EXHUST HOSPITL GRDE QUIET TYPE WITH DISSIPTIVE SILENCER PRODUCT OVERVIEW Nailor Single Duct Exhaust Terminal Units are used to modulate exhaust flow from an
More informationMOUNTING ARRANGEMENT OPTIONS OVERVIEW
ELT DRIVE SIDEWLL PROPELLER FNS MOUNTING RRNGEMENT OPTIONS OVERVIEW Page Mounting rrangement Description 2-3 Housing Heavy-gauge, all galvanized G-90 steel housing provides a simple solution to installing
More informationCONCENTRIC Product Information & Applications
CONCENTRIC Product Information & pplications Concentrics s the leading manufacturer of Concentric Diffusers for the past 30 years, Ruskin Rooftop Systems offers a cost effective way of distributing air
More informationOPERATOR MANUAL IMPORTANT INFORMATION, KEEP FOR OPERATOR
OPERATOR MANUAL IMPORTANT INFORMATION, KEEP FOR OPERATOR This manual provides information for: THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE. READ, UNDERSTAND AND FOLLOW THE INSTRUCTIONS AND WARNINGS
More informationHORD HOSPITAL OPERATING ROOM AIR CURTAIN
HORD HOSPITAL OPERATING ROOM AIR CURTAIN The Hospital Operating Room Diffuser (HORD) air curtain system is engineered specifically for the demanding needs of operating room environments. The HORD air curtain
More informationInstallation, Operation and Maintenance Manual
Document 452413 Kitchen Hoods Type I and Type II Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble,
More informationFilter Hood Model CA-S
Model CA-S Application This hood, suspended from the ceiling, is designed to capture, clean and evacuate hot air, smoke and grease vapours produced by cooking surfaces. Its effectiveness ensures the safety,
More informationMODELS GED/GSD, eged/egsd, DFE/DFS, DDE/DDS
LINE OVERVIEW Jenco s Direct Drive Sidewall Propeller line is designed to exhaust or supply large volumes of air at relatively low static pressures. With 3 types of construction, the direct drive models
More informationDonn. Air Diffuser. Technical Data. plenum. diffuser frame. Features
Technical Data Donn Features The DONN brand air diffuser provides air delivery and return for the ceiling system. Air is supplied through the lay-in diffuser, which is placed on the 2 x 2, narrow-suspension
More informationB. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.
PART 1 - GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More informationWhen Time Matters! listed Fire Damper
listed Fire Damper The FAST fire damper is offered as an option for containing fire and smoke under the hood in the event of a fire from a cooking appliance. Construction : The fire damper is assembled
More informationKVL-P with Plate Shelf
The model of Capture Jet TM hood is a highly efficient kitchen ventilation hood that removes contaminated air and excess heat emitted by cooking equipment, helping to provide a comfortable and clean environment.
More informationMODELS LCE/LCS, L2E/L2S, L3E/L3S
ELT DRIVE SIDEWLL PROPELLER FNS LINE OVERVIEW Jenco s elt Drive Sidewall Propeller line is designed to exhaust or supply large volumes of air at relatively low static pressures. With 3 levels of construction,
More informationHORD HOSPITAL OPERATING ROOM AIR CURTAIN
HORD HOSPITAL OPERATING ROOM AIR CURTAIN The Hospital Operating Room Diffuser (HORD) air curtain system is engineered specifically for the demanding needs of operating room environments. The HORD air curtain
More informationDONN Brand Air Diffuser
Technical Data DONN Brand Air Diffuser Features The DONN Brand air diffuser provides air delivery and return for the ceiling system. Air is supplied through the lay-in diffuser which is placed on the 2
More informationMODEL COMPARISON MOUNTING ARRANGEMENT OPTIONS
LINE OVERVIEW S&P s Direct Drive Sidewall Propeller Fan line is designed to exhaust or supply large volumes of air at relatively low static pressures. With 3 types of construction, the direct drive models
More informationSINGLE DUCT TERMINAL UNITS 3000 SERIES
000 SERIES 000 SERIES VRIBLE OR CONSTNT VOLUME PRODUCT OVERVIE Nailor 000 Series Single Duct Terminal units are simply put, versatile. hether the requirement calls for a constant or variable air volume
More informationINLINE CENTRIFUGAL DUCT FANS Direct and Belt Driven Models ZIDK and ZIBK
INLINE CENTRIFUGAL DUCT FANS Direct and Belt Driven Models ZIDK and ZIBK DESIGNED AND ENGINEERED TO MEET INDUSTRY NEEDS Air Zoë Centrifugal Inline Duct fans have been developed to efficiently handle the
More informationLINEAR DIFFUSERS AND BAR GRILLES
LINEAR DIFFUSERS AND AR GRILLES LINEAR DIFFUSERS AND AR GRILLES LINEAR SLOT DIFFUSER PLENUMS FOR TECHZONE TYPE CEILINGS Model Series 5300TZ Plenums are designed to fit the 5000TZ Series Slot Diffusers.
More informationPerforated Face Ceiling Diffusers
February 2011 Perforated Face Ceiling Diffusers Perforated Face Ceiling Diffuser Models PD, DFP and DPP Features NEW DROP PLQUE DESIGN 3 Model Types 1, 2, 3 or 4 way ir Patterns Extruded luminium Sections
More informationMODELS GED/GSD, eged/egsd, DFE/DFS, DDE/DDS
LINE OVERVIEW S&P s Direct Drive Sidewall Propeller Fan line is designed to exhaust or supply large volumes of air at relatively low static pressures. With 3 types of construction, the direct drive models
More informationforward curved inline duct blowers
Defining Innovation. forward curved inline duct blowers TYPE DBS (Single) DBT (Twin) BULLETIN 4220 January 2011 Duct Blowers General Information Twin City Fan s belt driven DBS (single) and DBT (twin)
More informationGeneral Purpose Walk-In Fume Hood
General Purpose Walk-In Fume Hood with Vertical Rising Sash Available Models: Open By-Pass Restricted By-Pass Auxiliary Air Available Option: Adjustable Baffles Air Flow and Static Pressure Alarms Service
More informationARROW INDUSTRIAL PRODUCTS
IP-2R ARROW INDUSTRIAL PRODUCTS For Applications in Industrial, Power Plant & Commercial Projects ARROW UNITED INDUSTRIES ARROW UNITED INDUSTRIES has specialized in the manufacturing of air control products
More informationCANOPY HOOD ACCESSORIES
CANOPY HOOD ACCESSORIES CONTENTS ITEM PAGE ITEM PAGE GREASE FILTERS TRAPPER...K2-3 affle....k4-5 FILTER RACKET... K5 LIGHTING... K6, K8-10 CAP STRIPS... K6 DIVIDER ARS... K6 GREASE CUPS.... K6 SILICONE
More informationIAQ. Model AVC. SINGLE DUCT VAV Model AVC
NON FAN POWERED UNITS SINGLE DUCT VAV Model AVC Model AVC The Carnes Model AVC is available as a basic control unit with open end discharge, with an optional multi-discharge adapter module, or sound attenuator
More informationGeneral Purpose Walk-In Fume Hood
General Purpose Walk-In Fume Hood with Vertical Rising Sash Available Models: Open By-Pass Restricted By-Pass Auxiliary Air Available Option: Adjustable Baffles Air Flow and Static Pressure Alarms Service
More information3900 Dr. Greaves Rd. Kansas City, MO (816) FAX (816) ABD-SEA-E
3900 Dr. Greaves Rd. Kansas City, MO 64030 (816) 761-7476 FAX (816) 765-8955 -SEA-E AUTOMATIC BALANCING DAMPER WITH REGISTER BOX AND SUPPLY/EXHAUST GRILLE APPLICATION Ruskin Model -SEA-E provides precise
More informationSTEEL LOUVERED DIFFUSERS [CFM Range is only a guide. See Manufacturer Catalog for complete data. All NC Levels in Acceptable Range<32.
STEEL LOUVERED DIFFUSERS TUTTLE & BAILEY Model 1300 - Round Neck Steel, Lay-In Tee Bar Mounting Neck Size Panel Size CFM Range Price Each Volume Damper Model RBN *6 12 x 12 75-180 $19 $12 6 24 x 24 75-180
More informationRegisters for spiral ducts
Registers for spiral ducts RGS-3 5 The RGS-3 is a supply/return register with adjustable double deflection blades and a volume damper designed specifically for direct mounting on a spiral duct. The use
More informationCommercial Kitchen Hoods Installation, Operation, and Maintenance Manual
Commercial Kitchen Hoods Installation, Operation, and Maintenance Manual RECEIVING AND INSPECTION Upon receiving unit, check for any interior and exterior damage, and if found, report it immediately to
More informationKVM KVM. Capture Jet Hybrid Backshelf Hood. Capture Jet TM Hybrid Backshelf Hood
Capture Jet Hybrid Backshelf Hood The hybrid backshelf model of Capture Jet hood is a highly efficient kitchen ventilation hood that removes contaminated air and excess heat emitted by cooking equipment,
More informationConcentric Supply/Return Diffusers. Models CSR & CSR-P. Redefine your comfort zone.
Concentric Supply/Return Diffusers Models CSR & CSR-P Redefine your comfort zone. www.titus-hvac.com Concentric Supply/Return Diffusers Models CSR & CSR-P Plenum CSR Rectangular Ceiling Diffuser Combination
More informationCentrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile
Centrifugal Cabinet s BCF Belt Drive Low-Profile November 204 BCF Centrifugal Cabinet Contents Standard Construction Features... 3 Options and Accessories... 4 Filter and Mixing Box Data... 5 Typical Installations...
More informationFiltered Kitchen Supply Packaged Ventilator
Filtered Kitchen Supply Packaged Ventilator Page Introduction........................................... 2 Information............................................ 3 Specifications and Dimension Data KD................................................
More informationSECURITY PRODUCTS GENERAL PRODUCT OVERVIEW. Security Products
GENERAL PRODUCT OVERVIEW Security Products Nailor offers a complete line of Security Grilles, Registers and Diffusers. The product line includes grilles and registers for maximum, medium and minimum security
More informationDesigner Wall Range Hood Installation. Installation Tutorial Video
Designer Wall Range Hood Installation Installation Tutorial Video 9 Designer Wall Range Hood Installation Please unpack your range hood when it is delivered and inspect to ensure all parts are included.
More informationModel FDD Dynamic Curtain Fire Damper 1-½ or 3 Hour, UL555 Listed
Tag: Project: Engineer: Contractor: Location: ate: pplication: rchitect: Submitted by: The NC model F fire damper utilizes a curtain style blade to prevent the spread of fire through a penetration in a
More informationLABGARD FEATURES
LABGARD 425 - FEATURES Front Filter Removal and Maintenence Minihelic Guage Sliding Tempered Glass Window Closes Completely Duplex Outlet 10 Access Opening Ergonomic PVC Armrest Optional Base Stand Clean
More informationHORD INSTALLATION & SERVICE MANUAL. Hospital Operating Room Diffusers INSTALLATION & SERVICE MANUAL. Date: 06 / 12 Reference # : E-10 1
HORD Hospital Operating Room Diffusers Date: 06 / 12 Reference # : E-10 1 2 Table of Contents Prior to Installation... 4 Ductwork Layout... 4 Installation of HORD Air Curtain System...5-9 T-Bar Ceiling...5-6
More informationLINEAR SLOT DIFFUSERS PLENUMS
LINEAR SLOT DIFFUSER PLENUMS ADAPTORS FOR MODEL SERIES 5000 LINEAR SLOT CEILING DIFFUSERS Standard Models: 5350(I) 1/2" (13) Slot 5375(I) 3/4" (19) Slot 5310(I) 1" (25) Slot Modified Performance Models:
More information95G2E PRODUCT SPECIFICATIONS 95% TWO-STAGE CONSTANT TORQUE GAS FURNACES CONTROLS VENTING CONFIGURATIONS HEAT EXCHANGER DESIGN INSTALLATION FEATURES
95G2E PRODUCT SPECIFICATIONS 95% TWO-STAGE CONSTANT TORQUE GAS FURNACES FORM NO. 95G2E-100 (04/2016) CONTROLS Two stage gas valve Integrated ignition and fan control Control board retains last ten (10)
More informationXeteX, Inc. All Rights Reserved.
Model XC Indoor or outdoor mounted, simple, in-case aluminum flat plate exchanger with options for frost control. Ideal for inline installations: in duct-work systems, in built-up units, or in modular
More informationADJUSTABLE SLOT DIFFUSER TYPE: SE800
TYPE: SE800 Installation dimensions Construction with hanger brackets Construction without hanger brackets D C Application 7 E A 0 7 E A 0 The slot diffuser, type SE800 is used for the supply of cooled
More informationMODELS LCE/LCS, L2E/L2S, L3E/L3S
LINE OVERVIEW S&P s Belt Drive Sidewall Propeller line is designed to exhaust or supply large volumes of air at relatively low static pressures. With levels of construction, the belt drive models are for
More informationComplete HVAC Capability
Air Handling Units Brochure 1110 January 2006 Complete HVAC Capability MEA Horizontal Draw-Thru to Size 65 Vertical Draw-Thru to Size 50 1000 to 60,000 CFM Forward Curved or Airfoil Wheels Inlet Vane Option
More informationIN STAL LA TION IN STRUC TIONS FOR CON CEN TRIC DIF FUSER
IN STAL LA TION IN STRUC TIONS FOR CON CEN TRIC DIF FUSER UNIT FILTER PLENUM CONTROL MOTOR ECONOMIZER FRESH AIR EXHAUST AIR ROOF CURB FLEXIBLE DUCT CON CEN TRIC DIFFUSER BOX Concentric Diffuser Flush Mount
More informationSupreme AirLV- FUME HOODS. KEWAUNEE encouraging new discovery LOW CONSTANT VOLUME
Supreme AirLV- LOW CONSTANT VOLUME FUME HOODS KEWAUNEE encouraging new discovery Supreme Air LV Fume Hood Low Velocity Low Volume Full Access Hold-Open Catch for set-up sash position Flush Mounted Convergent
More information2520- EC Motor Speed Controller
2520- EC Motor Speed Controller T1 AC Line Voltage From Contactor T2 or Neutral 760-ECM ECM Motor BLACK ORANGE BLACK RED (+) Signal 24VAC (-) GND Features Motor Types: ECM (dc brushless) Motors Motor Speed:
More informationCentrifugal Cabinet Fans Model BCF Belt Drive Low-Profile
Centrifugal Cabinet s BCF Belt Drive Low-Profile May 2007 BCF Belt Drive Cabinet s Greenheck belt drive low-profile cabinet fans, BCF, are designed for efficiency and reliability in supply, exhaust or
More informationHCD-135. Industrial Control Damper. Application and Design. Ratings (see page 2 and 3 for specific limitations) Standard Construction.
Application and Design Model is a heavy duty industrial control damper with a flanged frame. It is designed to control airflow and provide shut off in HVAC or industrial process control systems. A variety
More informationARROW UNITED INDUSTRIES
IP-3R ARROW UNITED INDUSTRIES Building Tomorrow s Ventilation Today Heavy Duty Dampers Industrial, Power Plant & Commercial Applications ARROW UNITED INDUSTRIES has specialized in the design and manufacturing
More informationSmith Memorial Stude t Union itchen Hood Replacement
Advancement of Construction Technology SUBSTITUTION REQUEST The Construction Specifications Institute Northwest Region TO: PROJECT: PSU Facilities Smith Memorial Stude t Union itchen Hood Replacement SPECIFIED
More informationRERV & RERVX RERVLP. Rotary Energy Recovery Ventilators. Low Profile Indoor Rotary Energy Recovery Ventilators
Version: Dec. 01, 2004 RERV & RERVX Rotary Energy Recovery Ventilators Indoor and Outdoor Installations 250 20,000 CFM Capacities RERVLP Low Profile Indoor Rotary Energy Recovery Ventilators Ideal for
More informationAir Flow Factors. Alnor Model 6070, 6000, 2220, or 2220-A Probe Orientation
ir Flow Factors Model: TDC irflow Measurements Procedure 1. Record diffuser velocities with lnor probe in the locations and orientation shown the velocity Measurement Location Chart. Note: Each diagram
More informationSD-1250 and SD-1600 Series Smoke Dampers
SD-1250 and SD-1600 Series Smoke Dampers Product Bulletin Code No. LIT-1201592 Issued January 30, 2014 Supersedes October 14, 2013 Johnson Controls provides a leakage-rated damper for life safety smoke
More informationA. Product Data: For each type of product. TLC ENGINEERING FOR ARCHITECTURE - PROJECT NO AIR DUCT ACCESSORIES
SECTION - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this
More informationMIN/MAX PERFORMANCE IN INCHES WG
Fans Roof Exhaust Direct Drive - G Model G Centrifugal Roof Exhaust fans are direct drive. These fans are specifically designed for roof mounted applications exhausting relatively clean air. Fan wheels
More informationFAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design
FAN TERAL UNITS Constant Volume (Series Flow), Standard Design Models ACF w/o Coil ACW w/hot Water Coil ACE w/electric Coil The Carnes constant volume fan terminal unit provides constant air volume to
More informationJanuary, 2014 Page 1 of 6
Part 1 General 1.1 Summary.1 Unless otherwise indicated, follow the standards below when specifying chemical fume hood modifications or installations. These standards are not intended to restrict or replace
More informationMODEL IFG INDIRECT FIRED MAKE-UP AIR HEATER
L (Housing Arr. H) 4" 6" A=Blower B=Filter C=Intake Downturn Plenum W Intake damper (Optional) H Birdscreen " Curb Cap D Electrical connection H Housing V-bank filters intake hood Gas connection E Lifting
More informationInstallation, Operation and Maintenance Manual
Document 481488 Auto-Cleaning Hood Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate
More informationIAQ. Model AVW. SINGLE DUCT w/hot WATER HEAT Model AVW
SINGLE DUCT w/hot WATER HEAT Model AVW Model AVW The Carnes Model AVW is available as a basic control unit with hot water reheat and open end discharge, with an optional sound attenuator module, and optional
More informationSINGLE DUCT TERMINAL UNITS
www.igcaire.com SINGLE DUCT TERMINAL UNITS Direct Digital Control, Pressure Independent FEATURES 22 Gauge Galvanized Steel Casing Construction with a 20 Gauge Casing Option that Provides Strength and Product
More informationFSD36, FSD36LP COMBINATION FIRE AND SMOKE DAMPER
3900 Dr. Greaves Rd. Kansas City, MO 64030 (816) 761-7476 FX (816) 765-8955 FSD36, FSD36LP COMINTION FIRE ND SMOKE DMPER 1 1 /2 HOUR UL555 RTED, UL555S LEKGE CLSS 2 PPLICTION Ruskin FSD36 Series low leakage
More informationACTIVE CHILLED BEAM 6 1/4" HEATING 9 1/2" DISCHARGE DIRECTION. 1 7/8" u 1/4" NOZZLE SIZE:
LINEAR 24" WIDE Submittal Sheet WATER COIL CONNECTIONS 9 1/2" 6 1/4" HEATING 9 3/8" COOLING PRIMARY AIR CONNECTION DISCHARGE DIRECTION 17 1/16" FACE WIDTH 23 3/4" 2-WAY SHOWN DISCHARGE DIRECTION MOUNTING
More informationCentrifugal Inline Fans Models SQ-M and BSQ-M. Direct and Belt Drive
Centrifugal Inline s Models SQ-M and BSQ-M Direct and Belt Drive July 2010 Centrifugal Inline Duct s Greenheck's model SQ-M and BSQ-M centrifugal square inline fans feature a unique combination of installation
More informationEGG CRATE RETURN GRILLE
80 EGG CRATE RETURN GRILLE 80 The 80 Series is available in various mounting styles and features sturdy construction, consisting of a heavy gauge aluminum grid core, optional extruded aluminum borders
More informationCENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VRBK
CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VRBK CENTRIFUGAL UPBLAST ROOF EXHAUSTERS COMMERCIAL KITCHEN APPLICATIONS Belt Driven Model VRBK DESIGNED AND ENGINEERED TO MEET INDUSTRY NEEDS The Carnes Company
More informationSECURITY PRODUCTS GENERAL PRODUCT OVERVIEW. Security Products
GENERAL PRODUCT OVERVIEW Security Products Nailor offers a complete line of Security Grilles, Registers and Diffusers. The product line includes grilles and registers for maximum, medium and minimum security
More informationVolume Flow Limiters Type VFL
X X Volume Flow Limiters Type Aerodynamic damper blade Sticker showing volume flow rates Set the volume flow rate Insert Volume flow limiter for insertion into ducting Circular, mechanical self-powered
More informationRoof & Sidewall Mounted
G, G Roof & Sidewall Mounted 4 E40001 - G and G UL/cUL Power Ventilators for Smoke ontrol Systems MH11711 - G UL/cUL Listed 705 is standard on In Stock models G and G are M Licensed for Sound and ir Performance
More information13 SEER Light Commercial 3 Phase
13 SEER Light Commercial 3 Phase Packaged Gas / Electric RGE13 Features and Benefits Form No. AC-RGE13-100 (04/2013) Refrigerant System Environmentally friendly R410A refrigerant Copper tubing with enhanced
More informationCUSTOM FLOW ARCHITECTURAL SLOT DIFFUSER
ARCHITECTURAL SLOT DIFFUSER Custom Flow (CF) slot diffusers are uniquely designed for curving and long continuous installations. The CF offers a large range of airflow flexibility with one or two slot
More informationRequires Ductwork and Blower
6' Protector XStream Laboratory Hood 9840600 is shown with SpillStopper Work Surface 9849800, Protector Acid Storage Cabinet 9901100 and Protector Standard Storage Cabinet 9900100. Requires Ductwork and
More informationFN Fan-Coil Units High-Performance, Horizontal
FN Fan-Coil Units High-Performance, Horizontal Model FNX Exposed-Cabinet Dimensional Data Notes: 1. All dimensions are in inches [mm] and are +/- 1/8" [3 mm]. Metric values are soft conversions. 2. See
More informationProtector XStream Laboratory Hood is shown with SpillStopper Work Surface , Protector Acid Storage Cabinet and Protector
Protector XStream Laboratory Hood 9840600 is shown with SpillStopper Work Surface 9849800, Protector Acid Storage Cabinet 9901100 and Protector Standard Storage Cabinet 9900100. Protector XStream Laboratory
More informationAIRODYNE CATALOGUE VOLUME CONTROL TAMPERS CONSTRUCTION / MATERIALS
AIRODYNE CATALOGUE VOLUME CONTROL TAMPERS CONSTRUCTION / MATERIALS Airodyne multi leaf volume control tampers have been specifically designed for use in air conditioning and ventilation system for volume,
More informationGRAVITY INTAKE AND EXHAUST ROOF VENTILATORS
GRAVITY INTAKE and EXHAUST ROOF VENTILATORS SECTION 21 GRAVITY INTAKE AND EXHAUST ROOF VENTILATORS Series GE and GI Low Silhouette This attractive low silhouette design is available in specific versions
More informationHCD-230 Industrial Control Damper
Application and Design Model is a heavy duty industrial control damper with a flanged frame. It is designed to control airflow and provide shut off in HVAC or industrial process control systems. A variety
More informationFSD60, FSD60LP COMBINATION FIRE AND SMOKE DAMPER 1 1 /2 HOUR UL555 RATED, UL555S LEAKAGE CLASS 1
3900 Dr. Greaves Rd. Kansas City, MO 64030 (816) 761-7476 FX (816) 765-8955 FSD60, FSD60LP COMINTION FIRE ND SMOKE DMPER 1 1 /2 HOUR UL555 RTED, UL555S LEKGE CLSS 1 PPLICTION Ruskin FSD60 Series ultra
More informationIAQ. ROUND DUCT RETROFIT Model ARR
Non Fan Powered Units ROUND DUCT RETROFIT Model ARR IAQ External Insulation Standard The Carnes Model ARR offers low pressure drop, low sound levels, and valve characteristics which create stable control
More informationProtector Demonstration Hoods
Protector Demonstration Hoods Protector Demonstration Hoods are low profile, light-duty fume hoods designed to provide close observation of procedures during educational demonstrations. ll models feature:
More informationScope and Application of ASTM 1704, Standard Test Method for Capture and Containment Performance of Commercial Kitchen Exhaust Ventilation Systems
Scope and Application of ASTM 1704, Standard Test Method for Capture and Containment Performance of Commercial Kitchen Exhaust Ventilation Systems The capture and containment exhaust air flow rates for
More informationRECTANGULAR, 2-HOUR FIRE RATED, ZERO-CLEARANCE GREASE DUCT CO.
RECTANGULAR, 2-HOUR FIRE RATED, ZERO-CLEARANCE GREASE DUCT CO. For over 75 years, Van-Packer has supplied venting products to the Commercial and Industrial heating and process markets. For the past 30
More informationA95-2V. 95% Gas Furnaces Two-Stage Variable Speed HEAT EXCHANGER DESIGN CONFIGURATIONS
Two- Variable Speed HEAT EXCHANGER DESIGN 409 Stainless steel primary heat exchanger material AL29-4C Stainless steel secondary heat exchanger Non-welded crimped S-curve primary heat exchanger design for
More informationOVERVIEW Combination Supply/Return Diffuser (SARM)
OVERVIEW Combination Supply/Return Diffuser (SARM) APPLICATION INFORMATION The extruded aluminum square and rectangular supply and return diffusers are designed principally for packaged roof top type heating
More informationLAMINAR FLOW DIFFUSER Model DLAB
Laminar & Radial Flow Diffuser LAMINAR FLOW DIFFUSER Model DLAB Application Laminar Flow diffusers are used to deliver air to surface directly underneath in a non-aspirating air pattern, with the minimum
More informationKEES, INC. BALANCING MANUAL
KEES, INC. Products for Sheet Metal HVAC, Food Service, & Architectural Construction Industries 400 S. INDUSTRIAL DRIVE ELKHART LAKE, WISCONSIN 53020 920 876-3391 FAX 920 876-3065 FORWARD: BALANCING MANUAL
More informationAir Handling Unit Fan Selection Guide
KEES Air Handling Unit Fan Selection Guide This document applies to models: DFG Direct Fired Gas Heater IFG Indirect Fired Gas Heater MUA Tempered Air NTS Non-Tempered Supply Table of Contents: Page 2-4
More informationPrice O.R. Systems AIR CURTAIN SYSTEM
Price O.R. Systems AIR CURTAIN SYSTEM The Price Air Curtain System includes non-aspirating laminar flow diffusers directly above the surgical area with a surrounding four-sided linear slot diffuser system
More informationElectric Coil [Make-Up Air / Displacement Ventilation / Space Heating] System
V-Series (rev. 08/17/10) Electric Coil [Make-Up Air / Displacement Ventilation / Space Heating] System Note: Optional items and/or items requiring a choice, are shown between brackets and/or parentheses
More informationAmericraft is dedicated to assist you, our customer, in all aspects of your air moving requirements.
mericraft Manufacturing Company Inc. has been manufacturing quality industrial fans and ventilation products since 1946. Our 50+ years of proven experience, strong national reputation and excellent customer
More information