Horizontal Air Curtains

Size: px
Start display at page:

Download "Horizontal Air Curtains"

Transcription

1 Horizontal Air Curtains HAC Series Horizontal Air Curtains produce a high velocity curtain of ambient air to prevent the accumulation of ice and snow from entering switches. These cold air snow clearing devices consist of a compact blower unit and ducting system that delivers airflow to the switch mechanism. The blower unit is an electrically powered centrifugal fan equipped with a low velocity air intake. The blower output is ducted below the rails to nozzles mounted within the railway switch. From the two nozzles, mph high velocity air streams are directed towards the point of the switch. QHAC Series Quiet Horizontal Air Curtains are designed for use in residential areas, with reduced sound pressure levels below 60 dba at 0 feet. Figure 26 QHAC Quiet Horizontal Air Curtain Figure 27 Standard HAC Horizontal Air Curtain Model Coding HAC H 2 - DT Voltage 1-240V* 2-208V 3-460V 4-7V Frequency 1-1 Ph 3-3 Ph Power HP - up to #14 switch HP - up to #20 switch Track Options 1 - One track 2 - Multiple tracks Accessories D - Delay Start Timer T - Temperature Switch Model Series HAC Fastrax Horizontal Air Curtain QHAC Fastrax Quiet Horizontal Air Curtain *240V - only available option for 1 Phase. Profi l e H - High Profi le L - Extra Low Profi le Horizontal Air Curtains 31

2 Features Standard HAC series horizontal air curtains Quiet (low noise) QHAC series horizontal air curtains Recommended Use HP HACs on switches up to #14 Accessories Temperature Switch Automatic startup in low temperatures to maximize snow clearing Conserves energy and run time by only running when temperature is below set point HP HACs on switches up to #20 Power HP Volts Phase HAC FL Amps Note: Actual current draw varies with temperature, altitude and voltage. Controls Weather-tight all stainless steel control box with clasp for padlock Delay Start Timer Staggers starting time for minimizing inrush current for multi-unit installations Remote/Auto/Manual selector switch Motor starting contactor with overload protection Air Output HP 200 cfm, HP 3000 cfm Sound Pressure Level Standard HAC series - 6 dba at 0 feet Quiet (low noise) QHAC series - 60 dba at 0 feet Construction Galvanized steel for maximum corrosion protection Control Option Part No. Delay Start Timer Temperature Switch 1842 Match balanced impeller and motor for long vibration free life Centrifugal fan, direct drive Fan balanced to less than 0.1 ips pk to pk Air Intake Profile High profile air intake for areas with excessive snowfall Extra low profile air intake to provide minimum obstruction for areas with minimal snowfall Rotating nozzles and adjustable vane to direct air where needed Peak air speeds of over 140 MPH, highest rated switch protection available Horizontal Air Curtains Electrically isolated from crossducts Extension ducts available 32

3 Air Curtain Selection HAC Series Horizontal Air Curtains (Standard) Table 18 HAC Series Horizontal Air Curtains - High Profile Intake HAC HAC HAC HAC HAC6729 HAC HAC6629 HAC HAC6829 HAC HAC6929 HAC6930 Table 19 HAC Series Horizontal Air Curtains - Low Profile Intake HAC HAC HAC HAC HAC6726 HAC HAC6626 HAC HAC6826 HAC HAC6926 HAC6927 QHAC Series Horizontal Air Curtains (Quiet - for Residential Areas) Table 20 QHAC Series Horizontal Air Curtains - High Profile Intake HAC HAC HAC HAC HAC6736 HAC HAC6636 HAC HAC6836 HAC HAC6936 HAC6937 Horizontal Air Curtains 33

4 Table 21 QHAC Series Horizontal Air Curtains - Low Profile Intake HAC HAC HAC HAC HAC6723 HAC HAC6623 HAC HAC6823 HAC HAC6923 HAC6924 Air Curtain Ductwork Air Intake Electrical Box Integrated Acoustic Enclosure, Intake, and Motor Rain Cover Blower Blower Motor Rain Cover Transition Duct Motor Transition Duct Motor Cross Duct Cross Duct End Duct HAC Series - Crib Duct Assembly End Duct QHAC Series - Crib Duct Assembly Transition Duct Horizontal Air Curtains Ductwork End Duct Deflectors Tie Duct Ballast Retainer Flexible Duct HAC/QHAC Series - Tie Duct Assembly 34

5 Crib Duct Systems Table 22 Crib Duct Systems Nominal Clearance/Rise Crib Duct Systems Dimensions (in.) Nozzle Length A B C D E 2 in.* 40 in.** 120 in / 12 in in / 6 in in / 0 in *Systems with 2 in. nozzles are intended for installation in the second crib, or 40 in. nozzles in the third crib ahead of the switch points. **40 in. nozzles are recommended for use with quiet systems for maximum noise reduction. Horizontal Air Curtains Ductwork 3

6 Tie Duct Systems Table 23 Tie Duct Systems Nominal Clearance/Rise Tie Duct Systems Dimensions (in.) Rail Base Width A B C D E 6 in.. in. 126 / / / Horizontal Air Curtains Ductwork 36

HAC/QHAC Series. Installation, Operation, & Maintenance Instructions. Horizontal Air Curtain and Quiet Horizontal Air Curtain

HAC/QHAC Series. Installation, Operation, & Maintenance Instructions. Horizontal Air Curtain and Quiet Horizontal Air Curtain IMPORTANT INSTRUCTIONS - SAVE THESE INSTRUCTIONS Read all instructions before installing or using the horizontal air curtain. Please adhere to instructions published in this manual. Failure to do so may

More information

HAC/HBD Series. Installation, Operation, & Maintenance Instructions. Horizontal Air Curtain for Hot Box Detectors

HAC/HBD Series. Installation, Operation, & Maintenance Instructions. Horizontal Air Curtain for Hot Box Detectors IMPORTANT INSTRUCTIONS - SAVE THESE INSTRUCTIONS Read all instructions before installing or using the horizontal air curtain for hot box detectors. Please adhere to instructions published in this manual.

More information

WAC Air Curtains Technical Guide

WAC Air Curtains Technical Guide TGWAC-2 WAC Air Curtains Technical Guide FOR WIND STOPPING, INSECT CONTROL, AND ENVIRONMENTAL SEPARATION IN COMMERCIAL AND INDUSTRIAL APPLICATIONS TABLE OF CONTENTS Introduction......................................................................2

More information

MODEL FF50 CEILING FAN

MODEL FF50 CEILING FAN MODEL FF50 CEILING FAN SPECIFICATION SHEET Simple installation dependability make this odor moisture removing fan a real value. Matte white polymeric blends well with any decor Torsion spring grill mounting

More information

Direct Gas-Fired Heating

Direct Gas-Fired Heating Direct Gas-Fired Heating Model DG 800 to 15,000 cfm Up to 1,600,000 BTU/hr Optional Evaporative Cooling January 2005 PRODUCT FEATURES Model DG Direct Gas-Fired Make-Up Air Unit The Greenheck model DG is

More information

Laboratory Exhaust Systems

Laboratory Exhaust Systems Laboratory Exhaust Systems Vektor -HS, Vektor -MS and Vektor -CS with Variable Geometry Nozzle September 017 Vektor -HS, Vektor -MS and Vektor -CS Greenheck s Variable Geometry Nozzle exhaust systems allow

More information

Need a. Bathroom Fan?

Need a. Bathroom Fan? Need a Bathroom Fan? ASX CEILING FANS Features ASX VCDD and VCDK Ceiling Ventilators have been designed to give quality conscious architects, design engineers, builders and specifiers the ultimate in heavy

More information

ceiling & inline/cabinet ventilators

ceiling & inline/cabinet ventilators Air Moving Solutions. ceiling & inline/cabinet ventilators T-Series ( T TL ) CATALOG 4600 March 2012 Ceiling&InlineVentilators T-Series T TL Twin City Fan & Blower s T Series Ceiling and TL Series Inline/Cabinet

More information

CEILING & INLINE/CABINET VENTILATORS

CEILING & INLINE/CABINET VENTILATORS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS CEILING & INLINE/CABINET VENTILATORS T-Series TL-Series CATALOG 4600 MARCH 2018 CEILING & INLINE VENTILATORS OVERVIEW T I TL T-Series

More information

OPERATING MANUAL MODEL NO. 953 STANDARD & MODEL NO. 952 LOW PROFILE 5 HP 230V 1 PHASE 230V 1 PHASE AC DRIVE 460V/575V 3 PHASE GAS FIRED HOT AIR BLOWER

OPERATING MANUAL MODEL NO. 953 STANDARD & MODEL NO. 952 LOW PROFILE 5 HP 230V 1 PHASE 230V 1 PHASE AC DRIVE 460V/575V 3 PHASE GAS FIRED HOT AIR BLOWER OPERATING MANUAL MODEL NO. 953 STANDARD & MODEL NO. 952 LOW PROFILE 5 HP 230V 1 PHASE 230V 1 PHASE AC DRIVE 460V/575V 3 PHASE GAS FIRED HOT AIR BLOWER TRACK SWITCH SNOW MELTER WITH STEEL TIE DUCT MANUFACTURED

More information

INSTRUCTIONS INSTALLATION OF NEMA-3R KIT FOR 43, 44 & 52 FRAME AF-6 DRIVES INTO WELDED ENCLOSURES

INSTRUCTIONS INSTALLATION OF NEMA-3R KIT FOR 43, 44 & 52 FRAME AF-6 DRIVES INTO WELDED ENCLOSURES INSTRUCTIONS INSTALLATION OF NEMA-3R KIT FOR 43, 44 & 52 FRAME AF-6 DRIVES INTO WELDED ENCLOSURES This instruction sheet is for the installation of NEMA -3R kits available for the AF-6 series drives frames

More information

IN-LINE CENTRIFUGAL DUCT FANS VT Series

IN-LINE CENTRIFUGAL DUCT FANS VT Series IN-LINE CENTRIFUGAL DUCT FANS VT Series DESCRIPTION The VT series of circular in-line duct centrifugal fans consists of model variations within nominal model sizes of,,,,, and mm respectively. The VT range

More information

TURNING AIR INTO SOLUTIONS. CEILING & INLINE/CABINET VENTILATORS. T-Series TL-Series

TURNING AIR INTO SOLUTIONS. CEILING & INLINE/CABINET VENTILATORS. T-Series TL-Series TURNING AIR INTO SOLUTIONS. CEILING & INLINE/CABINET VENTILATORS T-Series TL-Series CATALOG 4600 March 2018 CEILING & INLINE VENTILATORS Overview T I TL Twin City Fan & Blower s T-Series Ceiling and TL-Series

More information

MODELS FF & FFC CEILING AND INLINE/CABINET VENTILATORS

MODELS FF & FFC CEILING AND INLINE/CABINET VENTILATORS Model FF Model FFC Model ff Features Exhaust air up to 1500 CFM Forward curve centrifugal wheel for high static pressure capabilities to 1 w.g. Resilient mount, low RPM motor for quiet operation (except

More information

TURNING AIR INTO SOLUTIONS. COMMERCIAL DUTY PLENUM FANS EPLFN EPLQN

TURNING AIR INTO SOLUTIONS. COMMERCIAL DUTY PLENUM FANS EPLFN EPLQN TURNING AIR INTO SOLUTIONS. COMMERCIAL DUTY PLENUM FANS EPLFN EPLQN CATALOG 455 June 2014 PLENUM FANS Overview EPLFN I EPLQN Plenum fans are unhoused fans designed to operate inside of field-fabricated

More information

forward curved inline duct blowers

forward curved inline duct blowers Defining Innovation. forward curved inline duct blowers TYPE DBS (Single) DBT (Twin) BULLETIN 4220 January 2011 Duct Blowers General Information Twin City Fan s belt driven DBS (single) and DBT (twin)

More information

COMMERCIAL DUTY PLENUM FANS

COMMERCIAL DUTY PLENUM FANS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS COMMERCIAL DUTY PLENUM FANS EPLFN EPLQN CATALOG 455 JUNE 2014 PLENUM FANS Overview EPLFN I EPLQN Plenum fans are unhoused fans designed

More information

Filtered Kitchen Supply Packaged Ventilator

Filtered Kitchen Supply Packaged Ventilator Filtered Kitchen Supply Packaged Ventilator Page Introduction........................................... 2 Information............................................ 3 Specifications and Dimension Data KD................................................

More information

P3RC-12 SEER 2 Ton thru 4 Ton Units Cooling: 23,800 to 48,000 Btuh

P3RC-12 SEER 2 Ton thru 4 Ton Units Cooling: 23,800 to 48,000 Btuh TECHNICAL SPECIFICATIONS P3R(A,C) Series Single Packaged Air Conditioner, Single Phase P3RA-10 SEER 2 thru 5 Ton Units Cooling: 24,000 to 59,000 Btuh P3RC-12 SEER 2 Ton thru 4 Ton Units Cooling: 23,800

More information

AIR CURTAINS AIR CHAMBER DESIGN

AIR CURTAINS AIR CHAMBER DESIGN AIR CURTAINS AIR CHAMBER DESIGN Pittsburgh, PA Akron, OH Atlanta, GA Los Angeles, CA INDEX How an Air Curtain Works...3 Making an Air Curtain...3 Choosing The Right Air Curtain...4-5 Energy Saving & Return

More information

LIST PRICES WAC AIR CURTAINS

LIST PRICES WAC AIR CURTAINS PRICE SHEET PSWAC-2 EFFECTIVE: March 1, 2011 SUPERSEDES: PSWAC-1 LIST PRICES WAC AIR CURTAINS 4830 TRANSPORT DRIVE, DALLAS, TX 75247 PHONE: 214-638-6010 FAX: 214-905-0806 WAC AIR CURTAINS Basic Unit ITEM

More information

Electric Furnace KF/KFS Series

Electric Furnace KF/KFS Series Electric Furnace KF/KFS Series KF/KFS 20 20 1 A B C D A: Series B: 20-208V 24-240V 48-480V C: Kilowatts D: 1 or 3-phase Heavy duty open-coil element Direct drive motor Up to 3-speed motor Standard 24 Volt

More information

Centrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile

Centrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile Centrifugal Cabinet s BCF Belt Drive Low-Profile November 204 BCF Centrifugal Cabinet Contents Standard Construction Features... 3 Options and Accessories... 4 Filter and Mixing Box Data... 5 Typical Installations...

More information

Multi-Port Centrifugal Fans for Round Duct

Multi-Port Centrifugal Fans for Round Duct Multi-Port entrifugal Fans for Round when you need to exhaust many points to one VS Series Fantech VS Series ompact, quiet and dependable Multi-unit housing makes incredible demands on ventilation. Fantech

More information

Circular Duct Fan prioair

Circular Duct Fan prioair Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans Circular Duct Fan prioair More performance. Less energy consumption. The new EC circular duct

More information

GUIDE SPECIFICATIONS CE Series Two Stage R-410A

GUIDE SPECIFICATIONS CE Series Two Stage R-410A GUIDE SPECIFICATIONS CE Series Two Stage R-410A GENERAL Units shall be performance certified to ISO standard 13256-1 for Water Loop Pump, Ground Water Pump and Ground Loop Pump applications. Units shall

More information

MODELS STXD & STXDe DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTERS

MODELS STXD & STXDe DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTERS MODELS & e DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTERS MODEL DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTER MODEL FEATURES Exhaust air up to 4,780 CFM in high static pressure applications up to 1-1/2 w.g. Attractive

More information

MODELS FF & FFC CEILING AND INLINE/CABINET VENTILATORS

MODELS FF & FFC CEILING AND INLINE/CABINET VENTILATORS Model FF Model FFC MODEL FF FEATURES Exhaust air up to 1500 CFM Forward curve centrifugal wheel for high static pressure capabilities to 1 w.g. Resilient mount, low RPM motor for quiet operation Speed

More information

SQUARE INLINE CENTRIFUGAL FANS

SQUARE INLINE CENTRIFUGAL FANS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS SQUARE INLINE CENTRIFUGAL FANS DSI BSI CATALOG 40 FEBRUARY 07 SQUARE INLINE CENTRIFUGAL FANS Overview DSI BSI Twin City Fan & Blower

More information

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS R FORM NO: MS0305F Products That Perform...By People Who Care AIR - COOLED SPLIT SYSTEM AIR CONDITIONERS WITH SCROLL COMPRESSORS 50 Hz COOLING CAPACITY- 60 MBH TO 1360 MBH ACCS SERIES HEB-D, EB-D SERIES

More information

CONTROL DAMPERS. Models 1810 & Model Model Model 1370

CONTROL DAMPERS. Models 1810 & Model Model Model 1370 CONTROL DAMPERS CONTROL DAMPERS MODELS 1810 & 1820 MANUAL ALANCING DAMPERS STEEL Models 1810 and 1820 have been engineering and designed for manual balancing applications in low to medium pressure and

More information

Centrifugal Cabinet Fans Model BCF Belt Drive Low-Profile

Centrifugal Cabinet Fans Model BCF Belt Drive Low-Profile Centrifugal Cabinet s BCF Belt Drive Low-Profile May 2007 BCF Belt Drive Cabinet s Greenheck belt drive low-profile cabinet fans, BCF, are designed for efficiency and reliability in supply, exhaust or

More information

DVAX-ARS. Roof-mounted unit for mechanical smoke extract

DVAX-ARS. Roof-mounted unit for mechanical smoke extract Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans DVAX- Roof-mounted unit for mechanical smoke extract 2 DVAX DVAX- Roof-mounted axial fan unit

More information

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C PH120 R410a Refrigerant Rooftop Packaged INDOOR COIL ENTERING AIR TEMP 0 c DB WB 21 23 25 27 29 31 PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C 30 35 40 45 Cap Cap Cap Cap 17 115.3 70.7 11.5

More information

High Capacity Ventilation

High Capacity Ventilation High Capacity Ventilation DECEMBER 2012 Broan high capacity fans are an exceptionally quiet solution to continuous ventilation. With their heavy-duty motors, high capacity fans are an ideal solution for

More information

400ºC/2h centrifugal roof fans with horizontal or vertical air outlet CHT 200 4T BS. Installed capacity

400ºC/2h centrifugal roof fans with horizontal or vertical air outlet CHT 200 4T BS. Installed capacity 400ºC/2h centrifugal roof fans with horizontal or vertical air outlet : 400ºC/2h centrifugal roof fans with horizontal air outlet, hood in aluminium : 400ºC/2h centrifugal roof fans with vertical air outlet,

More information

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS 550.13-TG1Y(98) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS HCA300, 360, 80 & 600 5 THRU 50 NOMINAL TONS HCA80 DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece

More information

VANEAXIAL & TUBEAXIAL FANS

VANEAXIAL & TUBEAXIAL FANS BULLETIN 482 July 2008 VANEAXIAL & TUBEAXIAL FANS Type "S" Belt Driven Featuring Welded Steel Propellers Models VSBD & TSBD Model TSBD Belt Driven Tubeaxial Type "S" Vaneaxial & Tubeaxial Fans For applications

More information

IN-LINE RECTANGULAR FANS IRB / IRBS IRB

IN-LINE RECTANGULAR FANS IRB / IRBS IRB IN-LINE RECTANGULAR FANS IRB / IRBS IRB IN-LINE RECTANGULAR FANS IRB / IRBS IRB and IRBS are a compact series of centrifugal type exhaust and supply in-line duct fans for air conditioning systems. They

More information

Centrifugal Spun Aluminum Products

Centrifugal Spun Aluminum Products Centrifugal Spun Aluminum Products SDB SDBD STXB STXD Downblast & Upblast Centrifugal Roof Wall Exhausters Designed with Efficiency in Mind CSAP_0415 April 2015 Centrifugal Spun Aluminum Line Overview

More information

GR4GD Series. Single Packaged Gas/Electric Units TECHNICAL SPECIFICATIONS. GR4GD 13 SEER 2 Ton thru 5 Ton Units FEATURES AND BENEFITS

GR4GD Series. Single Packaged Gas/Electric Units TECHNICAL SPECIFICATIONS. GR4GD 13 SEER 2 Ton thru 5 Ton Units FEATURES AND BENEFITS TECHNICAL SPECIFICATIONS GR4GD Series Single Packaged Gas/Electric Units GR4GD 13 SEER 2 Ton thru 5 Ton Units The GR4GD Series single packaged gas/electrics are high efficiency self contained cooling units

More information

The Industrial Choice. Model SCDD Direct Drive. Model SCBD Belt Driven SQUARE INLINE FANS. Direct Drive & Belt Driven Model SCDD / SCBD

The Industrial Choice. Model SCDD Direct Drive. Model SCBD Belt Driven SQUARE INLINE FANS. Direct Drive & Belt Driven Model SCDD / SCBD The Industrial Choice. Model SCDD Direct Drive Model SCBD Belt Driven SQUARE INLINE FANS Direct Drive & Belt Driven Model SCDD / SCBD BULLETIN 40 January 007 Square Inline Centrifugal Fans General Information

More information

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS G115QX G115X ELECTRICAL FREQUENCY VOLTAGE PRIME STAND BY 50Hz 3ph 400/230v 107.7kVA / 86.2kW 118.5kVA / 94.8kW 60Hz 3Ph 380/220v 102.0kVA / 81.6kW 111.9kVA

More information

HIGH TEMPERATURE TWIN SQUIF FANS

HIGH TEMPERATURE TWIN SQUIF FANS HIGH TEMPERATURE FANS HIGH TEMPERATURE FOR SMOKE EXTRACT CERTIFIED TO EN12101-3-2002. 374 029 2085 8200 BENEFITS QUIET AND POWERFUL SOLUTIONS High performance centrifugal motor/impeller combination providing

More information

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW R410a Refrigerant SHS25 Split Ducted Model INDOOR COIL ENTERING AIR TEMP DB WB 21 2 25 27 29 1 Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE 0 5 40 45 17 2.4 1.8 11. 22.2 1.4 11.9 21.1 12.9 12.2

More information

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW R410a Refrigerant SHS35 Split Ducted Model INDOOR COIL ENTERING AIR TEMP DB WB 21 23 25 27 29 31 Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE 30 35 40 45 17 34.1 21.1 11.4 32.5 20.4 11.7 30.8

More information

TECHNICAL GUIDE. Echelon MODELS: FC8S GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES

TECHNICAL GUIDE. Echelon MODELS: FC8S GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES TECHNICAL GUIDE Echelon MODELS: FC8S GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE NATURAL GAS 40-130 MBH INPUT EFFICIENCY RATING CERTIFIED DESCRIPTION These high efficiency, dedicated

More information

FRP Fans: CLUB Series Performance and Technical Information

FRP Fans: CLUB Series Performance and Technical Information FRP Fans: CLUB Series 1500-7300 Performance and Technical Information Verantis Environmental Solutions Group provides solutions for most common and complex situations including repair, rebuilding, field

More information

DS4BD-KB Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Air Conditioner 13 SEER Residential System 1.

DS4BD-KB Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Air Conditioner 13 SEER Residential System 1. TECHNICAL SPECIFICATIONS DS4BD-KB Series R-410A High Efficiency Air Conditioner 13 SEER Residential System 1.5 5 Ton Capacity The DS4BD-KB Series now offers the choice of an air conditioner that uses a

More information

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved Centrifugal Roof Supply Fans Models and Forward Curved April 2008 Centrifugal Filtered Roof Supply Fan When you buy a Greenheck model or, you receive a fan with the industry s best performance and durability

More information

Explosion Proof Electric Fan/Blower - C1D1-1/3 HP Engine - Fan Only- 50' SOOW w/ EPP Cord Cap

Explosion Proof Electric Fan/Blower - C1D1-1/3 HP Engine - Fan Only- 50' SOOW w/ EPP Cord Cap Explosion Proof Electric Fan/Blower - C1D1-1/3 HP Engine - Fan Only- 50' SOOW w/ EPP Cord Cap Part #: EPF-10P.3-NFK-50C Page: 1 Made in Texas The EPF-10P.3-NFK-50C from Larson Electronics is an Explosion

More information

Defining Innovation. mixed flow fans. TYPE QSL (Standard) QSLR (Restaurant) QSLSH (Smoke and Heat) QFE (Fume Hood Exhaust)

Defining Innovation. mixed flow fans. TYPE QSL (Standard) QSLR (Restaurant) QSLSH (Smoke and Heat) QFE (Fume Hood Exhaust) Defining Innovation. mixed flow fans TYPE QSL (Standard) QSLR (Restaurant) QSLSH (Smoke and Heat) QFE (Fume Hood Exhaust) BULLETIN 1060 February 2011 QSL Mixed Flow Fans Benefits of Mixed Flow Fans Twin

More information

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW MODELS: D4HH 024 THRU 180 York horizontal ductable air conditioning packages offer a complete line of

More information

TECHNICAL GUIDE AFFINITY MODELS: PS8 GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES

TECHNICAL GUIDE AFFINITY MODELS: PS8 GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES TECHNICAL GUIDE AFFINITY MODELS: PS8 GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE NATURAL GAS 40-130 MBH INPUT EFFICIENCY RATING CERTIFIED DESCRIPTION These high efficiency, dedicated

More information

Eco Mixed Flow (emf) Energy Saver. Terminal Box. Performance. Quality Assurance. Impellers. Accessories. Motors

Eco Mixed Flow (emf) Energy Saver. Terminal Box. Performance. Quality Assurance. Impellers. Accessories. Motors Eco Mixed Flow (emf) High efficiency Mixed Flow Fan with guide vanes Available in sizes 355 to 710mm dia. IP54 Fan rating (duct mounted) Operating temperatures up to 80 C (see technical specification)

More information

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw Air-to-Water Reverse Cycle Heat Pumps VLH 504 to 1204 126 to 294 kw 133 to 307 kw Technical Brochure TM VLH-N.3GB Date : June 2005 Supersedes : TM VLH-N.2GB/07.04 Specifications Advantages Range extension

More information

Stylus 4G. Mini Split Air Conditioners. Stylus 4G Series Convertible Type 12,000-60,000 Btu/h MCX / MWX SERIES 50 Hz R22 / R410a

Stylus 4G. Mini Split Air Conditioners. Stylus 4G Series Convertible Type 12,000-60,000 Btu/h MCX / MWX SERIES 50 Hz R22 / R410a Stylus 4G Mini Split Air Conditioners Stylus 4G Series Convertible Type 12,000-60,000 Btu/h MCX / MWX SERIES 50 Hz R22 / R410a Stylus 4G Comfort Solutions Trane proudly presents the Stylus 4G air conditioners

More information

Sentinel D-Box Single Fan

Sentinel D-Box Single Fan Sentinel D-Box Single Fan Duct size to 5mm Performance - Airflow.1 to 1.6m 3 /s Pressure up to 65Pa Sentinel demand ventilation fan controller with lockable isolator Aluzinc contstruction suitable for

More information

R2H3. Product Specifications 3 PHASE HEAT PUMP COMPONENT. For Use With R 22 Refrigerant. 2 1/2 THRU 5 TONS 208 / 230 Volt, 3 phase, 60 Hz

R2H3. Product Specifications 3 PHASE HEAT PUMP COMPONENT. For Use With R 22 Refrigerant. 2 1/2 THRU 5 TONS 208 / 230 Volt, 3 phase, 60 Hz 3 PHASE HEAT PUMP COMPONENT 2 1/2 THRU 5 TONS 208 / 230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Scroll compressors on all models Compressors contain proper charge of mineral oil Suction line accumulator

More information

Inline and Roof Mounted Fans

Inline and Roof Mounted Fans CV Inline and Roof Mounted Fans Page Introduction........................................... 2 Construction Features................................. 3-4 Specifications and Dimension Data CVD (Direct Drive

More information

PERFORMANCE ENGINEERING

PERFORMANCE ENGINEERING PERFORMANCE ENGINEERING Every part, every component, every system on our engines is guided by Kohler s exclusive Performance Engineering. It s your assurance that every engine we produce will live up to

More information

INLINE CENTRIFUGAL DUCT FANS Direct and Belt Driven Models ZIDK and ZIBK

INLINE CENTRIFUGAL DUCT FANS Direct and Belt Driven Models ZIDK and ZIBK INLINE CENTRIFUGAL DUCT FANS Direct and Belt Driven Models ZIDK and ZIBK DESIGNED AND ENGINEERED TO MEET INDUSTRY NEEDS Air Zoë Centrifugal Inline Duct fans have been developed to efficiently handle the

More information

Industry best 5 year fan housing warranty, 1 year motor warranty

Industry best 5 year fan housing warranty, 1 year motor warranty MODELS & e DIRECT DRIVE CENTRIFUGAL DOWNBLAST ROOF EXHAUSTERS MODEL - DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTER MODEL FEATURES Exhaust air up to 4,980 CFM in high static pressure applications up to 1-1/2

More information

CENTRIFUGAL IN-LINE FANS VENT Series

CENTRIFUGAL IN-LINE FANS VENT Series Range of in-line duct centrifugal fans, manufactured from high grade corrosion resistant pressed galvanised steel and supplied as standard with a prewired wiring junction box and a robust mounting foot.

More information

P7RD-A Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner

P7RD-A Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner TECHNICAL SPECIFICATIONS P7RD-A Series Single Packaged Air Conditioner P7RD-A 13 SEER, R-410A 2 thru 5 Ton Units Cooling: 24,000 to 56,000 Btuh The P7 Series single packaged air conditioners are high efficiency

More information

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410. PART 1 - GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

Rotron NANOS Small Vaneaxial Fans

Rotron NANOS Small Vaneaxial Fans Rotron NANOS Small Vaneaxial Fans Nanos Small Vaneaxial Information Nanos Small Vaneaxial Fans are compact, high-speed fans with axial airflow. The impeller and guide vanes are of airfoil configuration

More information

VENT Series CENTRIFUGAL IN-LINE FANS VENT. In-Line duct fans. Mounting foot

VENT Series CENTRIFUGAL IN-LINE FANS VENT. In-Line duct fans. Mounting foot CENTRIFUGAL IN-LINE FANS Series Range of in-line duct centrifugal fans, manufactured from high grade corrosion resistant pressed galvanised steel and supplied as standard with a pre-wired wiring junction

More information

MODEL FF/FFC CEILING AND INLINE/CABINET VENTILATORS

MODEL FF/FFC CEILING AND INLINE/CABINET VENTILATORS MODEL FF/FFC CEILING AND INLINE/CABINET VENTILATORS APPLICATION The extremely quiet FF and FFC ventilators are used to exhaust air from a variety of commercial and institutional applications, such as restrooms,

More information

CRH RANGE - TECHNICAL DATA CENTRIFUGAL ROOF FANS

CRH RANGE - TECHNICAL DATA CENTRIFUGAL ROOF FANS ge 2 CENTRIFUGAL CRH RANGE - TECHNICAL ROOF DATA FANS FOR INDUSTRIAL / COMMERCIAL USE CRH - Horizontal Discharge CRV - Vertical Discharge CRL - Low Profile Uniclass L7534 Tel: +44 ()1494 522333 Fax: Vectaire

More information

Climate Control Products

Climate Control Products Products Filter Fans NEMA 1 Box Fan High airflow with low noise operations makes these versatile packaged fans very popular in a wide range of applications. Reversible mounting brackets allow user to push

More information

Mixed Flow Roof Fans (RMH)

Mixed Flow Roof Fans (RMH) Mixed Flow Roof Fans (RMH) Motors protected to IP44 Motor insulation Class B Maximum operating temperature 4 C Standard Thermal Overload Protection IP65 service isolator Bird guard included as standard

More information

Sentinel D-Box Twin Fan

Sentinel D-Box Twin Fan Sentinel D-Box Twin Fan Duct Sizes mm Performance - Airflow.1 to 1.3m 3 /s, Pressure up to 65Pa Sentinel demand ventilation fan controller with lockable isolator Latest energy saving EC/DC motors Aluzinc

More information

TURNING AIR INTO SOLUTIONS. CENTRIFUGAL ROOFTOP EXHAUST FANS LOW PROFILE HOODED & LOUVERED DCLH BCLH DCLP BCLP

TURNING AIR INTO SOLUTIONS. CENTRIFUGAL ROOFTOP EXHAUST FANS LOW PROFILE HOODED & LOUVERED DCLH BCLH DCLP BCLP TURNING AIR INTO SOLUTIONS. CENTRIFUGAL ROOFTOP EXHAUST FANS LOW PROFILE HOODED & LOUVERED DCLH BCLH DCLP BCLP CATALOG 4135 February 2017 PENTHOUSE ROOF VENTILATORS Overview DCLH I BCLH I DCLP I BCLP Model

More information

Commercial Blower Coil Air Handlers

Commercial Blower Coil Air Handlers Commercial Blower Coil Air Handlers MODEL : BDH(V)B - 048, 065, 080 7400 CMH - 14300 CMH 30 kw - 125 kw BCXB-PRC001-E4 Contents Model Number Description General Specification Standard Features Unit Configuration

More information

Environmental Series Air Curtains

Environmental Series Air Curtains INSTALLATION & OPERATING INSTRUCTIONS & PARTS MANUAL FOR ALL 120 and 230 VOLT 1/4, 1/2 AND 3/4 H.P. MOTOR MODELS Environmental Series Air Curtains READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL,

More information

TUBULAR CENTRIFUGAL INLINE FANS

TUBULAR CENTRIFUGAL INLINE FANS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS TUBULAR CENTRIFUGAL INLINE FANS MODEL TSL CATALOG 1001 APRIL 2014 CENTRIFUGAL INLINE FANS Model TSL The TSL is an inline centrifugal

More information

Q3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

Q3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS TECHNICAL SPECIFICATIONS Q3RD Series Single Packaged Heat Pump, Single Phase Q3RD-13 SEER 2 thru 4 Ton Units Cooling: 24,000 to 48,000 Btuh Heating: 23,200 to 48,000 Btuh The Q3 Series single packaged

More information

GP7RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner, Single Phase WARRANTY

GP7RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner, Single Phase WARRANTY TECHNICAL SPECIFICATIONS GP7RD Series Single Packaged Air Conditioner, Single Phase GP7RD 13 SEER, R-410A 2 thru 4 Ton Units Cooling: 24,000 to 47,000 Btuh The GP7 Series single packaged air conditioners

More information

engineering guide Air-Cooled Self-Contained Units

engineering guide Air-Cooled Self-Contained Units engineering guide Air-Cooled Self-Contained Units FORM 145.00-EG2 (1211) TABLE OF CONTENTS Air-Cooled Self-Contained Units Introduction...............................................................................

More information

Centrifugal Inline Fans Models SQ-M and BSQ-M. Direct and Belt Drive

Centrifugal Inline Fans Models SQ-M and BSQ-M. Direct and Belt Drive Centrifugal Inline s Models SQ-M and BSQ-M Direct and Belt Drive July 2010 Centrifugal Inline Duct s Greenheck's model SQ-M and BSQ-M centrifugal square inline fans feature a unique combination of installation

More information

TURNING AIR INTO SOLUTIONS. DIRECT DRIVE EXHAUST & SUPPLY PANEL FANS. Model TCPE

TURNING AIR INTO SOLUTIONS. DIRECT DRIVE EXHAUST & SUPPLY PANEL FANS. Model TCPE TURNING AIR INTO SOLUTIONS. DIRECT DRIVE EXHAUST & SUPPLY PANEL FANS Model TCPE CATALOG 4800 February 2017 PANEL FANS Overview TCPE TCPE panel fans are direct drive panel fans designed for low static pressures.

More information

MODEL FF/FFC CEILING AND INLINE/CABINET VENTILATORS

MODEL FF/FFC CEILING AND INLINE/CABINET VENTILATORS R MODEL FF/FFC CEILING AND INLINE/CABINET VENTILATORS APPLICATION The extremely quiet FF and FFC ventilators are used to exhaust air from a variety of commercial and institutional applications, such as

More information

P7RE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner

P7RE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner TECHNICAL SPECIFICATIONS P7RE Series Single Packaged Air Conditioner P7RE 14 SEER 2 thru 5 Ton Units Cooling: 23,800 to 56,000 Btuh The P7 Series single packaged air conditioners are high efficiency self

More information

Air Moving Solutions. MODULAR plenum fans

Air Moving Solutions. MODULAR plenum fans Air Moving Solutions. MODULAR plenum fans MPQN MPQS CATALOG 490 March 2012 PlenumFans Models MPQN MPQS The MPQN and MPQS offer many of the same advantages of the venerable EPQN plenum fan. The MPQN and

More information

Mixed-Flow Blowers Page Specifications and Dimension Data Performance Data Sound Data

Mixed-Flow Blowers Page Specifications and Dimension Data Performance Data Sound Data Mixed-Flow Blowers Page Introduction.......................................... 2-4 Standard Construction Features.......................... 5-7 Mixed-Flow Advantages.................................. 8

More information

TOP 10 NOISE CONTROL TECHNIQUES

TOP 10 NOISE CONTROL TECHNIQUES TOP 10 NOISE CONTROL TECHNIQUES The following are 10 simple noise control techniques that have wide application across the whole of industry. In many cases, they will produce substantial noise reductions

More information

ITEC High Efficiency EC Twin Fan for convenient fitting and full control. Casing constructed from 1.6mm Galvanised sheet steel

ITEC High Efficiency EC Twin Fan for convenient fitting and full control. Casing constructed from 1.6mm Galvanised sheet steel ITEC High Efficiency EC Twin Fan for convenient fitting and full control Casing constructed from 1.6mm Galvanised sheet steel Circular spigot connection Inline for ease of fitting into duct system Single

More information

Centrifugal Filtered Supply Roof Blowers

Centrifugal Filtered Supply Roof Blowers CFS Centrifugal Filtered Supply Roof Blowers Page Introduction...................................... 2 Specifications and Dimension Data................... 3 Typical Installation................................

More information

Practical examples of installation in the TD range

Practical examples of installation in the TD range Practical examples of installation in the TD range The TD-MIXVENT system offers the most versatile installation range on the market, as a result of its multiple combinations; it can be used in a large

More information

LBD-Series. Radiator-Cooled Load Bank. Description

LBD-Series. Radiator-Cooled Load Bank. Description Radiator-Cooled Load Bank Description Simplex LBD Load Banks are a special form of stationary, resistive, forced air-cooled load bank which utilizes the air outflow of an engine radiator for cooling of

More information

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO ISLAND RANGE HOOD

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO ISLAND RANGE HOOD Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO ISLAND RANGE HOOD Read All Instructions Thoroughly Before Beginning

More information

DCE 100 Series Dust Filter

DCE 100 Series Dust Filter Installation, Operation and Maintenance Manual DCE 100 Series Dust Filter Publication 2638B (GB) 0702 1419-8000A Donaldson Torit DCE reserve the right to alter design without notice. Freedom from patent

More information

TSAT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJTSA: Ventilation units with a forward-curved impeller.

TSAT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJTSA: Ventilation units with a forward-curved impeller. TSA TSAT CJTSA TSA: Single inlet, belt-driven centrifugal fans with shaft outlet and forward-curved impeller. TSAT: Single inlet, belt-driven centrifugal fans fitted with electric motors, a set of pulleys

More information

DF6SF Series Rev B TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

DF6SF Series Rev B TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS DF6SF Series Rev B Two-Stage Heat/Two-Stage Cool with Variable Speed Blower ihybrid Dual Fuel Package Units DF6SF 15 SEER, 81% AFUE, 8.0 HSPF 2 Ton thru 5 Ton Units These dual

More information

OPERATING MANUAL. centrifugal fan SAFETY PRACTICES

OPERATING MANUAL. centrifugal fan SAFETY PRACTICES 2237 MARSHALLTOWN BLVD. MARSHALLTOWN, IOWA 50158 PHONE: (641) 753-5601 TOLL FREE: 1-800-383-5601 FAX: (641) 752-9748 WWW.SPREAD-ALLMFG.NET OPERATING MANUAL centrifugal fan SAFETY PRACTICES 1. Have a qualified

More information

INSTALLATION INSTRUCTIONS K-SERIES UNDER CABINET HOOD

INSTALLATION INSTRUCTIONS K-SERIES UNDER CABINET HOOD Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS K-SERIES UNDER CABINET HOOD Read All Instructions Thoroughly Before Beginning Installation

More information

Compact Design BB101 & 93

Compact Design BB101 & 93 Acoustic Shield Natural Ventilation Acoustic Roof Vents Compact Design BB101 & 93 Standard / Twin Flow / Mixed Mode natural ventilation roof vents can be finished in any colour to compliment the architectural

More information

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved Centrifugal Roof Supply Fans Models and Forward Curved B U I L D I N G V A L U E I N A I R. April 2008 Centrifugal Filtered Roof Supply Fan When you buy a Greenheck model or, you receive a fan with the

More information

INSTALLATION INSTRUCTIONS CWEH6-K WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS CWEH6-K WALL MOUNT HOOD Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS CWEH6-K WALL MOUNT HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING

More information