Environmental Lab Tour Lab Overview
|
|
- Basil Lynch
- 5 years ago
- Views:
Transcription
1 Environmental Lab Tour Lab Overview Keystone Compliance s environmental test laboratory offers a well-lit, clean, temperature-controlled environment. The lab is powered by 2,000 amps, 480 volts of electrical service (bottom right) and offers a sound-insulated control room with windows on all sides of the lab (bottom left). The data acquisition system is a centralized system with data port connection boxes located throughout the lab. These data port connection channels are available to customers and they are recorded every minute of every day. Also, all vibration and shock capabilities are augmented through Spectral Dynamics Jaguar Controllers.
2 Environmental Lab Tour Panoramic Lab Photo Tour Picture 1
3 Environmental Lab Tour Panoramic Lab Photo Tour Picture 2
4 Environmental Lab Tour Panoramic Lab Photo Tour Picture 3
5 Environmental Lab Tour Panoramic Lab Photo Tour Picture 4
6 Environmental Lab Tour Climatics Temperature Chambers Keystone Compliance has two walk-in and seven reach-in temperature chambers. The chamber pictured on the right is cooled with twin 30 hp compressors for fast temperature transitions. The two photos below are of a temperature/humidity chamber with inside dimensions of 10 wide by 12 deep by 10 tall with a door measuring 8 wide by 9 tall. The seven reach-in chambers offer various ramp times and temperature ranges. Six of the reach-in chambers also have humidity capabilities.
7 Environmental Lab Tour Climatics Various Climatics Test Equipment Various other pieces of climatics equipment include: - IP Code Dust Chamber (bottom left). - Wind & Rain Test Blower that is capable of wind speeds up to 160 mph (bottom center). - Thermal Shock Chamber that includes two temperature chambers and an elevator between chambers. (bottom right) - Two Salt-Fog Chambers, one of which is 5 x3 x4 and the other is 8 x4 x4 (not shown) -Drip Pan for drip testing (not shown)
8 Environmental Lab Tour Dynamics Electrodynamic Shakers Keystone Compliance has three electrodynamic shakers. The shaker in the photo on the right is a medium-sized LDS 4,000 lbf shaker with 2 max displacement. The two photos below are of a large-sized 11,000 lbf shaker with 3 max displacement. Notice the pivot of the shaker head to allow for multiple axis testing. Both shakers pictured include a unibase with a hydrostatic slip table with journal bearings. This allows the shakers to test tall racks in the horizontal position.
9 Environmental Lab Tour Other Equipment Various Other Environmental Test Equipment Various other pieces of environmental test equipment include: - Dynamic Shock machine capable of thousands of G s on payloads up to 250 pounds (bottom left) - AGREE Temperature Over Vibration Chamber (bottom right) - Mechanical Shaker with a table size of 8 by 4. (not shown)
10 EMC/EMI Lab Tour Lab Overview Keystone Compliance s EMC/EMI test laboratory offers a well-lit, clean, temperature-controlled environment. The lab includes two fully-compliant three-meter chambers and two semi-anechoic test chambers. Pictured below is the existing EMC/EMI lab. The new lab is under construction but will offer the same aesthetic appeal.
11 EMC/EMI Lab Tour Testing Capabilities A summary of Keystone Compliance s EMC/EMI/RF testing capabilities includes the following: - Radiated immunity testing up to 200 V/m from 10 khz to 18 GHz - Radiated emissions testing up to 40 GHz - Surge testing to 10kV/10kA and higher - ESD testing up to 30 kv -Shielding Effectiveness from small panels and boxes all the way up to large enclosures and cabling, with wide Dynamic Range all the way to 18 GHz Pictured below are a military drone test program (left) and a field uniformity test (right).
12 EMC/EMI Lab Tour 3-Meter Chambers Keystone Compliance has two ANSI C63.4 (NSA) compliant 3-meter, semi- anechoic absorber / ferrite lined chambers. These 3-meter chambers allow Keystone Compliance to perform full qualification, 3-meter measurements in the frequency range of 30 MHz to 1 GHz required by the CISPR 22, CISPR 11 and FCC Part 15 standards, as well as to meet the field uniformity requirements of the EN standard. Further, to ensure these chambers continue to meet these evolving standards, they have been designed to perform testing up to and beyond 18 GHz.
13 EMC/EMI Lab Tour Semi-Anechoic Chambers Keystone Compliance has two semi-anechoic EMC test chambers for use in military, aerospace and automotive testing. There is one standard-sized chambers and one over-sized chamber. The oversized EMC test chamber measures 32 long by 20 wide by 10 high, is absorber / ferrite lined and accommodates large products such as automobiles, unmanned aerial vehicles and large industrial equipment. The chamber features large entry doors measuring 7 wide by 10 high, a flush mount 8 diameter turntable capable of rotating loads up to 8,000 pounds and an engine exhaust system which allows Keystone to perform testing on engine operated devices. Specific capabilities of the large test chamber include radiated emissions measurements in the frequency range of 10 khz to 40 GHz and radiated immunity/susceptibility capabilities of 10 khz to 18 GHz up to 200 volts/meter.
EMC and Durability Lab, HCL Technologies Ltd., #73-74, South Phase, Ambattur Industrial Estate, Chennai
Last Amended on - Page 1 of 10 I. EMI / EMC TESTS 1. IT Products / Household / Industrial / Medical / Network Telecommunications Equipment Radiated Emission Test (RE) CISPR11:2010 BSEN 55011:2010 CISPR22:2008
More informationHuntsville- Aerospace Testing & Engineering Services Highway 20 West Huntsville, AL 35806
Huntsville- Aerospace Testing & Engineering Services 7800 Highway 20 West Huntsville, AL 35806 Facility Overview Huntsville Facility Overview Site: Total Square Footage: 92 Acres 160,000 sq. ft. of Laboratory
More informationFRANKONIA. EDTC E-Drive Testing Chamber
EDTC E-Drive Testing Chamber E-Drive Testing Chamber Frankonia s EMC testing solution for powertrain components and systems relating to hybrid, electric, fuel cell and battery drive systems FRANKONIA FRANKONIA
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK
21-47 High Street, Feltham, Middlesex, TW13 4UN, UK Stratford Road Solihull West Midlands B90 4GW Contact: Mr C Gregory Tel: +44 (0)121 627 3225 Fax: +44 (0)121 627 4353 E-Mail: colin.gregory@trw.com Website:
More informationENVIRONMENTAL TESTING
ENVIRONMENTAL TESTING Environmental Testing Foreword & Introduction Tests Heat - Cold - Climate Page 3 Thermal Shock Page 4 Low - High Pressure Page 4 Vibration Page 5 Mechanical Shock Page 6 Corrosive
More informationSafety Standards. Model Number:
Highlights & Features RoHS Compliant Relay alarm indirection Built-in 2 channel DC OK signal Caused by rugged handing Conformal coating on PCBA to protect against chemical and dust pollutants Class I,
More informationThe SPIRA Advantage in Honeycomb Filters
The SPIRA Advantage in Honeycomb Filters s family of exceptional honeycomb filters includes our NEW Shielded Fan Filter, as well as our popular -Cell and Brass-Cell Shielded Air Vent Filters. All honeycomb
More informationTest report. Type VRLTC load tap changer VRLTC 1500A Type test summary report
Test report Type VRLTC load tap changer VRLTC 1500A Type test summary report Date: 10 October 2012 Type Test Summary Report Type VRLTC Vacuum/Reactance Load Tap Changer ABB has tested the Type VRLTC, vacuum
More informationAutomotive Sensor Products
DEF Level Sensing PWG Features Contactless linear position sensor Robust, simple, cost effective design Works with Ferrite magnet 4mT (40Gauss) Sensor stroke lengths up to 340mm Longer designs feasible
More informationSystems. Dynamic Test. Electrodynamic Vibration Test Systems
Systems 100 - water 120 kn cooled Electrodynamic Vibration Test Systems SW3-10480APP (100KN) SW3-10LS3-550APP (100KN) SW3-10650APP (100KN) SW3-12480APP (120KN) SW3-12LS3-550APP (120KN) Dynamic Test Technical
More informationAnechoic Chambers. Frankonia Turnkey Solutions Anechoic chambers for EMI/EMS tests according to IEC/EN/ISO/MIL and CISPR standards FRANKONIA
Anechoic Chambers Frankonia Turnkey Solutions Anechoic chambers for EMI/EMS tests according to IEC/EN/ISO/MIL and CISPR standards FRANKONIA The pole position. FRANKONIA Frankonia Group The FRANKONIA GROUP
More informationDSX-Series Vibration
THE DRIVING FORCE IN ELECTRODYNAMIC VIBRATION TESTING Vibration Experience That Counts A global vibration manufacturer for more than 35 years, Thermotron specializes in highperformance vibration test system
More informationamp ramp Operators Manual Page 1 Saftronics 2S Ltd Turnbridge Mills Quay Street Huddersfield West Yorkshire HD1 6QT
amp ramp Operators Manual Saftronics S Ltd Turnbridge Mills Quay Street Huddersfield West Yorkshire HD 6QT Tel: 0484 530893 Fax: 0484 550500 Website:www.saftronics.co.uk E-Mail: sales@saftronics.co.uk
More informationPARKING LOT SHERIDAN COLLEGE PARKING LOT LED RETROFIT PROJECT
SHERIDAN COLLEGE LED RETROFIT PROJECT VIVIX - GENERAL FEATURES General Features Applications: Parking Lot Residential Roadway Area Lighting Outdoor Lighting Housing Characteristics: Light-weight, high
More informationCAN and Serial Instrumentation
Instrumentation Models 3140 and 3141 www.curtisinstruments.com 1 Curtis Models 3140 and 3141 are designed to display critical vehicle and motor controller data in an easy-to-read and attractive LCD. The
More informationCiclo de vida de la medida en el desarrollo de componentes electrónicos para la automoción
Ciclo de vida de la medida en el desarrollo de componentes electrónicos para la automoción Tres Cantos Madrid 20 de Mayo 2016 Xavier Secall Laboratory Manager Electrical Engineering Europe & Africa xsecall@lear.com
More informationSystems. Dynamic Test. Electrodynamic Vibration Test Systems SW2-4445APP (40KN) SW2-5445APP (50KN) SW2-5,5LS3-445APP (55KN) SW2-7LS3-550APP (70KN)
Systems 40-70 kn air cooled Electrodynamic Vibration Test Systems SW2-4445APP (40KN) SW2-5445APP (50KN) SW2-5,5LS3-445APP (55KN) SW2-7LS3-550APP (70KN) Dynamic Test Technical subject to changes without
More informationTEST SYSTEM AND PRODUCT SOLUTIONS FOR FULL VEHICLES AND ESAs
TEST SYSTEM AND PRODUCT SOLUTIONS FOR FULL VEHICLES AND ESAs BEYOND MEASURE. ETS-LINDGREN IS AN EXPERIENCED PARTNER YOU CAN TRUST THE LEADER IN AUTOMOTIVE TEST AND MEASUREMENT INTRODUCES ITS NEW SERIES
More informationTest Report No.: SHHG BC Date: JAN.31,2013 Page: 1 of 12
Test Report No.: SHHG1211042519BC Date: JAN.31,2013 Page: 1 of 12 GOLDEN MOTOR TECHNOLOGY CO., LTD BLOCK 8, MODERN INDUSTRIAL CENTER, 801 CHANGWU MIDDLE ROAD, CHANGZHOU, JIANGSU, CHINA 213164 The following
More informationIMMOBILISER SYSTEM INTRODUCTION
IMMOBILISER SYSTEM INTRODUCTION 2017 Customer Base PRODUCT PICTURES KAT Part Nr. CUSTOMER DATE OF BEGINN SERIAL DELIVERY Immobiliser Type 1 (with TYCO Connectors) 33223 33241 Kramer Werke since 2006 Immobiliser
More informationCPS2000 Cabinet Power System
Input (Nominal): 90 Vac to 264 Vac (Autoranging) Output (Nominal): -48 Vdc (up to 28.8 A) and Optional 50 VA Ringing Generator The low-maintenance, outside-plant CPS2000 (Cabinet Power System) integrates
More informationRVS-DN Digital Reduced Voltage Motor Starter
RVS-DN Digital Reduced Voltage Motor Starter Specification Guide Specification Guide Contents 1.0 Introduction 2.0 Specifications 2.1 Standard Performance Features 2.2 Standard Protection Features 2.3
More informationEMC TEST REPORT. For The. 3-Phase Power Supply. Model: TPS300024
EMC TEST REPORT For The 3-Phase Power Supply Model: TPS300024 Prepared for: TDK-Lambda Americas, Inc. 401 Mile of Cars Way, Suite 325 San Diego, CA 91950, United States Testing performed per the following:
More information24V TO 13.5V FIXED OUTPUT VOLTAGE CONVERTER
3092 PRODUCTION RELESE B 3257 DDED TOLERNCES 52152 24V TO 13.5V FIXED OUTPUT VOLTGE CONVERTER PROPRIETRY THIS DRWING IS THE PROPERTY OF SURE POWER INC. and shall not be copied, reproduced, lent, or disposed
More informationFrankonia E-Drive Testing Chamber - Fixed Load Machine -
Frankonia E-Drive Testing Chamber - Fixed Load Machine - Requirements Standards CISPR & ISO CISPR and ISO conform test setup Respect of different test scenarios Interference suppressed instruments Secure
More informationDC (on) LED Signal. Multiple output connector for easy wiring
DIN Rail Mount, 5 x 7.5 mm or 5 x 5 mm Wide Power Range (0W-9W) Wide Adjustment Range Rugged for Industrial Use High Efficiency Lightweight and Compact Design year warranty Short Circuit Protection Overvoltage
More informationSYSTEM DATA. Slip Tables and Combos for Vibration Test Systems
SYSTEM DATA Slip Tables and Combos for Vibration Test Systems The LDS range of oil film slip tables are designed for ease of installation while providing the maximum flexibility to the test engineer. For
More informationEvolution of the standard CISPR25 to the Ed4. Impact on the design of vehicle component chambers and Frankonia solution EDTC
EMC Conference -- Turkey September 2015 Speaker: Richard Weininger Evolution of the standard CISPR25 to the Ed4. Impact on the design of vehicle component chambers and Frankonia solution EDTC Contents
More informationSurface mounting, flush mounting, and DIN track mounting
Solid-state Timer H3JA Economical, Compact, Plug-in Timer Time limit, ON-delay, operation with automatic resetting. DIN size (36 x 36 mm), fits standard 8-pin sockets. Wide choice of supply voltages: 24,
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 YANFENG GLOBAL AUTOMOTIVE INTERIOR SYSTEMS CO., LTD. AUTOMOTIVE TRIM & ELECTRONICS TESTING LABORATORY. China Technical Center No. 1001 North Qinzhou Rd. Shanghai,
More informationBatteries. Batteries. Accessories Guide Technical specifications are subject to change 2-27
Batteries M/A-COM portable radio battery packs are designed for safety and durability. Portable radio products that provide options for both trunked and conventional operation are for rugged use conditions
More informationDUAL 60V 20A POWER FLEX POWER SUPPLY INSTRUCTION MANUAL
72-7570 DUAL 60V 20A POWER FLEX POWER SUPPLY INSTRUCTION MANUAL Table of Contents Specification 1 Safety 3 EMC 4 Installation 5 Connections 5 Operation 6 Maintenance 8 Specification General specifications
More informationUSB3.0 for Active Optical Cable
USB3.0 for Active Optical Cable 1. Description 1. Basics: USB3.0 Active Optical Cable (AOC) speed up to 5 Gbps 2. Dimension of USB3.0 Type A male plug conforming requirements (Size: 56.1 x 8 x 16 mm).
More informationcomponenti elettronici electronic components FILTERS - CHOKES
www.comsel.it componenti elettronici electronic components FILTERS - CHOKES join us! IEC INLET FILTERS / POWER ENTRY MODULES 0012727 FN 281-2-06 SINGLE-PHASE P.E.M FILTER WITH FUSE AND SWITCH 2A* 40 0011891
More informationGB60S 60W Single Output General Purpose Series
Features 2 x 3 x 1.0 Package Operates to 80 C Ambient For 1U Applications 60W convection cooled Universal Input 90-264Vac Optional Power ON LED Approved to CSA/EN/IEC/UL60950-1, 2 nd Edition Efficiency
More informationServices Transport and PackagingTests Optimizationof Packagings Environmental Simulation Tests, Design Testing IP-Testing Packaging Validation and Pac
Accredited Test Lab for Environmental and Transport Simulation Tests HAMBURG BERLIN OCHSENHAUSEN CH-NEUHAUSEN Services Transport and PackagingTests Optimizationof Packagings Environmental Simulation Tests,
More informationAnechoic Chambers / RF-Shielded Rooms Turn-key solutions from Frankonia
Anechoic Chambers / RF-Shielded Rooms Turn-key solutions from Frankonia We supply turn-key shielded rooms and anechoic-chambers acc. to IEC/EN/ISO/MIL and CISPR-standards, including immunity and emission
More information产品技术规范. Product Name: Product Technical Specification SMARTSTONE. No.: CPFL0002 Version: A Issued date: Page 1 of 16
Product Name: TMAP Part Number: CPF00002 Drawing Number: CPFJ0002 Page 1 of 16 CONTENTS 1. General Data 1.1. Description 1.2. Installation Guide 1.3. Maximum ratings of pressure sensor 1.4. Operating characteristics
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ELEMENT MATERIALS TECHNOLOGY MINNEAPOLIS LLC (A subsidiary of Element Materials Technology Minneapolis Inc.) 9725 Girard Avenue South Minneapolis, MN 55431
More informationBE SURE POWER IS DISCONNECTED PRIOR TO INSALLATION! FOLLOW NATIONAL, STATE, AND LOCAL CODES! READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION!
INSTALLATION INSTRUCTIONS FOR SYMCOM S MOTORSAVER MODEL 460 BE SURE POWER IS DISCONNECTED PRIOR TO INSALLATION! FOLLOW NATIONAL, STATE, AND LOCAL CODES! READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION!
More informationEvolve LED Area Lighting EALS
Evolve LED Area Lighting EALS Product Features The EAL Area Light luminaires are the newest members of the GE Evolve LED Area Light family. They offer a wide range of optical patterns, color temperatures,
More information* Not illustrated in exploded view.
CKMTA12 & CKMTA24 Air Compressor Specs: ITEM # QTY DESCRIPTION PART # NOTES 01(a) 2 COMPRESSOR ASSEMBLY (12V) CKM01 1 Voltage 12 Volts (CKMTA12), 24 Volts (CKMTA24) 01(b) 2 COMPRESSOR ASSEMBLY (24V) CKM02
More informationMYPMA01218RCF-CAB Non-isolated type
FEATURES 120W DC-DC converter(216w peak) Output Voltage:12V Low ripple and Low surge output. Input Voltage:36V-75V Working Temperature -20 - +85 High Efficiency up to 95% Compact Size 86.5x122.4x35.4mm
More informationTechnical specifications
Technical specifications Type 3RW30 03 3RW3-1B0 3RW3-1B1 Control electronics Rated control supply voltage V 24 230 CDC 24 CDC (+10 %-15 %) 110 230 CDC (+10 %-15 %) Rated control supply Without fanwith
More informationTESTS, MEASUREMENTS, ANALYSIS VIBRATION AND PRESSURE TESTS ENVIRONMENTAL AND CORROSION TESTS
, MEASUREMENTS, ANALYSIS VIBRATION AND PRESSURE ENVIRONMENTAL AND CORROSION VIBRATION AND ENVIRONMENTAL MECHANICAL RESISTANCE VZLU TEST, a.s. provides a wide range of development, qualification and serial
More informationFrankonia BlueBox - Mobile Load Machine -
Frankonia BlueBox - Mobile Load Machine - Requirements Standards CISPR & ISO CISPR and ISO conform test setup Respect of different test scenarios Interference suppressed instruments Secure test environment
More informationOur test laboratory - Apparatebau Kirchheim-Teck GmbH
1 / 16 Test laboratory equipment 1 Microsection lab for crimp contacts Tensile, pressure and bending test machine: Static + dynamic Vibration test: Vibration + shock Climate tests: Temperature + humidity
More informationEMERGENCY VEHICLE BATTERY MANAGER PS2024
EMERGENCY VEHICLE BATTERY MANAGER PS2024 2 The PS2024 (Fig. 1) is designed as a on-vehicle battery charger / battery charge state monitor. While the vehicle is at its base or station, the charger is connected
More information3-Phase Military AC-DC Power Supply 3-Phase, VrmsL-L
-4-1U 3-Phase Military AC-DC Power Supply 3-Phase, 8-265 VrmsL-L 47-8 Hz Semi-Regulated 28 V-48 V 4 W 525 W Transient Input Power Input Frequency Output Voltages Output Power Sealed Construction, Ultra
More informationDr. Chris Borroni-Bird, VP, Strategic Development, Qualcomm Technologies Incorporated. Enabling Connected and Electric Vehicles
Dr. Chris Borroni-Bird, VP, Strategic Development, Qualcomm Technologies Incorporated Enabling Connected and Electric Vehicles 1 2 3 4 Introduction DSRC WEVC Summary Agenda 2 Multiple technologies intersect
More informationEvolve LED Area Lighting EALP
Evolve LED Area Lighting EALP Product Features The GE Evolve LED Area Light, EALP, is optimized for customers needing an energy saving LED solution while adding flexibility, style and scalability at at
More informationIncrease your communication capabilities for emergencies and scheduled events with a Secure Mobile Radio Site from Pepro.
+ Increase your communication capabilities for emergencies and scheduled events with a Secure Mobile Radio Site from Pepro. We are the leading manufacturer of patented shielded enclosure systems for mission
More informationNote1: tested at nominal Vin, full load and at +25 C ambient. Package (3) CTRL Logic (2)
Features Regulated Converters : Wide input voltage range.6kvdc Isolation UL, IEC/EN69 and EN certified Efficiency up to 88% OVP, OCP & OTP + C max. case temperature Description The RPA-AW series are high
More information3 Uninterruptible Power Systems
S4K2U and S4K2U-5 Industrial On-Line UPS The true on-line (double conversion) protection offered by the S4K2U Industrial UPS series eliminates a wider range of potential power problems (spikes, surges
More informationSeries 80 Mighty Mouse Technical Reference Complete Product Specification
Summary Performance Specifications Current Rating (Maximum): Size #23 Contact: 5 A., Size #20 contact: 7.5 A., Size #16 contact: 13 A., Size #12 contact: 23 A. Test Voltage (Dielectric Withstanding Voltage)
More informationOutput Current Input Current Over Load VDC VDC ma ma(typ.) ma(typ.) VDC μf %
Doc. EC-0093 FEATURES Industrial Standard 2"x1" Package Ultra-wide Input Range 9-36VDC, 18-75VDC, 40-160VDC I/O Isolation 3000VAC with Reinforced Insulation Operating Ambient Temp. Range -40 C to +88 C
More informationMitraset 19 Housings. Housing for electronic instruments
Housing for electronic instruments Mitraset 19 housings are in accordance with MIL-T 28800, MIL-STD 810 F, EIA and IEEE Standards and are designed to accommodate electronic devices in a 19 rack. They also
More informationFisher D4 Control Valve Assembly
D4 Valve Product Bulletin Fisher D4 Control Valve Assembly The Fisher D4 control valve is a compact, rugged globe valve designed primarily for high-pressure throttling applications using either pneumatic
More informationXSP Series XSPR LED Street/Area Luminaire Version A
XSP Series Product Description In addition to a low initial cost, the XSPR LED Street luminaire maintains the familiar look of the traditional cobrahead design and delivers substantial energy savings while
More informationEvolve LED Wall Pack. N Series (EWNB)
Evolve LED Wall Pack N Series (EWNB) Product Features The next generation of the GE Evolve LED Wall Pack is designed to efficiently illuminate walkways, area, and general lighting applications. The EWNB
More information1291BL Series Technical Specification Single-Axis Rate and Positioning Table System
Datasheet 1291BL Series Technical Specification Single-Axis Rate and Positioning Table System DESCRIPTION The Model 1291BL Single Axis Positioning and Rate Table System is designed to provide precise position,
More informationRVS-DX Digital Reduced Voltage Motor Starter
RVS-DX Digital Reduced Voltage Motor Starter Specification Guide Specification Guide Contents 1.0 Introduction 2.0 Specifications 2.1 Standard Performance Features 2.2 Standard Protection Features 2.3
More informationXSP Series XSP2 LED Street/Area Luminaire Double Module Version C
XSP Series XSP LED Street/Area Luminaire Double Module Version C Product Description Designed from the ground up as a totally optimized LED street and area lighting system, the XSP Series delivers incredible
More informationTools and Techniques for Ensuring Automotive EMC Performance and Reliability
Tools and Techniques for Ensuring Automotive EMC Performance and Reliability Todd Hubing Michelin Professor of Vehicular Electronics Clemson University Automobiles are Complex Electronic Systems Navigation
More informationBrüel & Kjær and LDS The Perfect Match SHORT FORM CATALOGUE
Brüel & Kjær and LDS The Perfect Match SHORT FORM CATALOGUE 4 Aerospace For any aircraft, helicopter, space vehicle or ballistic device, reliability is the number one priority. By using our vibration test
More informationUSB3.0 For Active Optical Cable SPECIFICATIONS
USB3.0 For Active Optical Cable SPECIFICATIONS MODEL Comoss PART NUMBER Custom PART NUMBER PRELIMINARY Ver.. 1.0 OFFICIAL Release Date: 2015-01-26 CUSTOMER BY PREPARED BY APPROVAL CHECK BY DESIGN BY Victor
More informationClimatic Wind Tunnel in Decatur Illinois Replicates Extreme Conditions
AutomationMedia.com January, 2015 Climatic Wind Tunnel in Decatur Illinois Replicates Extreme Conditions by Thomas R. Cutler Predicting the weather and its consequences is not easy. Each year Weather.com
More informationCRegulatory. Compliance: UL and CE APPENDIX C IN THIS CHAPTER. Installation Instructions Installation Guidelines System Installation Techniques
APPENDIX C CRegulatory Compliance: UL and CE IN THIS CHAPTER Installation Instructions Installation Guidelines System Installation Techniques Appendix C Regulatory Compliance: UL and CE 81 Regulatory Agencies
More informationFeatures. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter
Features TRIAC Dimmable LED Driver Triac dimmable with leading or trailing edge dimmers Class II with SELV output (no earth required) Extra-large screw terminals and integrated cable clamps for easy installation
More informationABI Cooler System Protoflight Performance
ABI Cooler System Protoflight Performance R. Colbert, G. Pruitt, T. Nguyen, J. Raab Northrop Grumman Space Technology Redondo Beach, CA, USA 90278 S. Clark, P. Ramsey ITT Industries Space Systems Division
More information2:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 90% Six-Sided Continuous Shield Available as Power Module (RPM30-E)
Features Regulated Converters 2:1 Wide Input Voltage Range 1.6kV Isolation UL Certified Efficiency up to % Six-Sided Continuous Shield Available as Power Module (RPM30-E) Description The series / converters
More informationXSP High Output Series XSP2 High Output LED Street/Area Luminaire Double Module
XSP High Output Series XSP High Output LED Street/Area Luminaire Double Module Product Description Designed from the ground up as a totally optimized LED street and area lighting system, the XSP High Output
More informationFeatures. 2-wire type available. Max. operation distance: 1.5 mm 0.06 in (Stable sensing range 0 to 1.2 mm 0.05 in)
817 Cylindrical Inductive Proximity Sensor SERIES Related Information General terms and conditions... F-3 Glossary of terms...p.1576~ guide... P.781~ General precautions... P.1579~ PHOTO PHOTO panasonic.net/id/pidsx/global
More informationEvolve LED Area Lighting
GE Lighting Evolve LED Area Lighting EALS imagination at work Product Features The GE Evolve LED Area Light, EALS, is optimized for customers requesting an energy saving LED solution while adding greater
More informationPRODUCT SPECIFICATION C00 Converter. 48/36V to 12V, 20 Amps w/switched Output
ISIONS DESCRIPTION DTE BY 001 3826 PRODUCTION RELESE 8/21/03 BF 002 4650 DD 6 PIN MTING CONNECTOR PN S 10/12/05 BF 003 4969 GENERL DOCUMENT MODIFICTIONS 6/29/0 GF 5065 ELECTRICL CHRCTERISTICS CHNGES 11/1/0
More information1291BL Series Technical Specification Single Axis Position and Rate Table System
Datasheet 1291BL Series Technical Specification Single Axis Position and Rate Table System DESCRIPTION The Model 1291BL Single Axis Position and Rate Table System is designed to provide precise position,
More informationFeatures. Regulated Converters. RP20-F 20 Watt 2 x 1 Single & Dual Output. RP20- _F/ Package 4) Control Logic (3) DC/DC Converter
Features Regulated Converters Description 2:1 Wide Input Voltage Range 1.6kV Isolation UL Certified Efficiency up to 89% Six-Sided Continuous Shield No Minimum Load The series / converters are certified
More informationSECTION MOTOR REQUIREMENTS for HVAC
PART 1 GENERAL 1.1 SECTION INCLUDES A. Single-phase electric motors B. Three-phase electric motors 1.2 REFERENCES SECTION 23 05 13 MOTOR REQUIREMENTS for HVAC A. ABMA 9 - Load Ratings and Fatigue Life
More informationSoftstarter Intelligent Controllers
Softstarter Intelligent Controllers Series Modes of Operation (Standard) Soft Start 100% Percent Voltage Initial Torque Start Run This method has the most general application. The motor is raised from
More informationMN/DOT Specification Light Emitting Diode (LED) Luminaire 03/20/2012
1. LISTING REQUIREMENTS MN/DOT Specification Light Emitting Diode (LED) Luminaire 03/20/2012 1.1. The Luminaire shall be listed by a National Recognized Testing Laboratory (NRTL) as defined by the U.S.
More informationDC-DC CONVERTERS 4:1 WIDE INPUT RANGE UP TO 9 WATTS SINGLE AND DUAL OUTPUT, SIP PACKAGE SWB9 SERIES
DC-DC CONVERTERS 4:1 WIDE INPUT RANGE UP TO 9 WATTS SINGLE AND DUAL OUTPUT, SIP PACKAGE FEATURES 4:1 Ultra Wide Input Range Output Current up to 2000 ma Miniature SIP (Single-In-Line) Package, 0.86 0.36
More informationUSB3.0 For Active Optical Cable SPECIFICATIONS
USB3.0 For Active Optical Cable SPECIFICATIONS PLUG, STD A USB 3.0 PLUG, STD A USB 3.0 MODEL COMOSS PART NUMBER USB3AOC-A/1-A/1-(X)M-XXX USB3AOC-A/1-AF/1-(X)M-XXX Custom PART NUMBER X PRELIMINARY Ver:
More information2:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 87% Low Profile, 10.2mm Height Over Current Protection
Features Regulated Converters 2:1 Wide Voltage Range 1.6kV Isolation UL Certified Efficiency up to 87% Low Profile, 10.2mm Height Over Current Protection Description The series / converters are certified
More informationW-VACi IEC medium voltage vacuum circuit breakers 12 kv, 17,5 kv and 24 kv
This is a photographic template your photograph should fit precisely within this rectangle. W-VACi IEC medium voltage vacuum circuit breakers 12 kv, 17,5 kv and 24 kv Mostapha Azzahimi Product Manager
More informationID ID. Series 19. Mechanical Products Company
H i g h A m p e r a g e 2 5 t o 2 0 0 A M P New LED tripid ID ID TM Option T y p e I & I I I V e h i c l e P r o t e c t i o n I P 6 7 & I P 6 9 K W a t e r p r o o f I g n i t i o n - P r o t e c t e
More information4:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 88% Six-Sided Continuous Shield Available as Power Module (RPM30-EW)
Features Regulated Converters Description 4:1 Wide Input Voltage Range 1.6kV Isolation UL Certified Efficiency up to 88% Six-Sided Continuous Shield Available as Power Module (RPM30-EW) The series wide
More informationIntrinsically safe presure transmitters for hazardous environments Type MBS 4201, MBS 4251, MBS 4701 and MBS Technical brochure
Intrinsically safe presure transmitters for hazardous environments Type MBS 4201, MBS 4251, MBS 4701 and MBS 4751 Technical brochure Features Ex ll 1G EEx ia llc T4 - T6 in compliance with ATEX 100a Applicable
More informationVIA Platform Environmental Qualification Testing Standards
VIA Platform Environmental Qualification Testing Standards Revision: 1 Report Dated: September 7 th 2016 Report Prepared By: Noel Joyce Reliability Lab Manager Page 1 of 16 Table of Contents 1. Purpose...
More informationSPECIFICATIONS UPS Triple Output 13.6VDC/213W, 48VDC/153W, 48VDC/39W
Page 1 / 7 Full operation without need of battery Two independent 48Vdc outputs for switching and control Local monitoring with 8 LEDs Remote monitoring with 4 alarm relays Monitoring and configuration
More informationAutomotive EMI measurements with multichannel time-domain systems
Automotive EMI measurements with Ferran Silva, Marc Aragón, Marc Pous, Marco Azpúrua Universitat Politècnica de Catalunya, Barcelona, Spain ferran.silva@upc.edu 1. Introduction 2. Full Time-Domain EMI
More informationDC-DC CONVERTERS 2:1 INPUT RANGE, UP TO 2 WATTS MEDICAL APPLICATIONS MTWA2 SERIES
DC-DC CONVERTERS 2:1 INPUT RANGE, UP TO 2 WATTS MEDICAL APPLICATIONS FEATURES 2:1 Wide Input Voltage Range: 4.5-12 Input, 9-18 and 18-36 and 36-75 5000Vac Input to Output 2MOPP Isolation Remote On/Off
More informationPresentation Soft starters 0 Altistart 48 soft start - soft stop units
Presentation Soft starters 5 6 7 65_Ver.-EN.fm/ Presentation (continued) Soft starters Applications The Altistart 8 soft start - soft stop unit is a controller with 6 thyristors which is used for the torque-controlled
More informationGE 8000-Line Motor Control Centers
GE 8000-Line -1 ENCLOSURE TYPES TYPE 1 General Purpose, Indoor Intended for use indoors, primarily to prevent accidental contact of personnel with the enclosed equipment, in areas where unusual service
More informationSINUS PENTA 2T/4T SINUS PENTA 2T/4T
SINUS PENTA 2T/4T SINUS PENTA 2T/4T Technical Highlights One product, 5 integrated functions - IFD (Inverter Frequency Drive): vector modulation function for general-purpose applications (V/F pattern).
More informationSubrange SmartWire-DT electronic motor starters. Basic function Reversing starters (complete devices)
DATASHEET - EMS-RO-T-9-SWD-ADP Reversing starter 9A with SmartWire-DT Part no. EMS-RO-T-9-SWD-ADP Catalog No. 172763 Eaton Catalog No. EMS-RO-T-9-SWD-ADP EL-Nummer 4110026 (Norway) Delivery program Product
More information(typ.) (Range) Load
FEATURES Highest Power Density 1" x 1" x 0.4" Shielded Metal Package Wide 2:1 Input Range Excellent Efficiency up to % Operating Temp. Range - C to + C Optional Heatsink I/O-isolation Voltage 10VDC Remote
More informationPRODUCT SPECIFICATION OUTPUT CURRENT (A) OUTPUT CURRENT TOLERANCE ±7% ±7% ±10% ±10% ±7% 1.8. Units % % % Typ. Typ.
0-10V Dimmable FEATURES: AC Input 100~277VAC Built-in Active PFC Function Protection: SCP / OVP / OTP 24V Auxiliary Output 0-10V Dimming Control Dimming 1 ~ 100 Flicker Free High Operating Ambient Temp.:
More informationActuator LA35. Data sheet LINAK.COM/TECHLINE
Actuator LA35 Data sheet LINAK.COM/TECHLINE LA35 The LA35 is a very quiet and powerful actuator, and provides a practical and cost-effective solution with low power consumption. The actuator is designed
More informationNational Automotive Testing Research & Development Infrastructure Project (Department of Heavy Industries, Government of India)
National Automotive Testing Research & Development Infrastructure Project (Department of Heavy Industries, Government of India) NATRIP is the most significant initiative in Automotive Sector by Govt. of
More informationAn Overview of Automotive EMC Standards & Emerging Requirements
An Overview of Automotive EMC Standards & Emerging Requirements 2015. 5. 29 Korea Automobile Testing & Research Institute (KATRI) TOPICs 1. Automotive Electronics of the Future 2. Automotive EMC Standards
More information