CASE STUDY: BERGEY EXCEL WIND TURBINE INSTALLATION NOVEMBER 2002

Size: px
Start display at page:

Download "CASE STUDY: BERGEY EXCEL WIND TURBINE INSTALLATION NOVEMBER 2002"

Transcription

1 CASE STUDY: BERGEY EXCEL WIND TURBINE INSTALLATION NOVEMBER 2002 Case Study compiled by: Rhonda Gatzke, Member GEO 11/2002

2 Some Some of of the the project project participants: participants: Metro Metro Parks Parks Green Green Energy Energy Ohio Ohio Geoff Geoff Greenfield, Greenfield, Third Third Sun Sun Installer Installer and and Distributor Distributor Phil Phil Irwin, Irwin, Vanner Vanner Inc. Inc. AC AC Power Power Inverter Inverter Provider Provider CONTENT Preparing the tower s foundation Assembling the tower Installing the wind turbine Erecting the wind mill Balance of System components Permits (Zoning, Building, FAA) 1

3 2 A hole hole is is drilled drilled for for a pier pier at at each each leg leg of of the the tower. tower. Construction Construction of of the the three three diameter diameter piers piers entails entails a total total of of yards yards concrete. concrete. Each Each pier pier is is feet feet deep deep and and contains contains an an engineered engineered pound pound cage cage of of rebar rebar to to provide provide the the foundation foundation with with appropriate appropriate tensile tensile strength. strength. Concrete Concrete is is innately innately strong strong in in compression. compression.

4 3 Four Four anchor anchor bolts bolts are are mounted mounted into into each each pier. pier. Each Each set set of of anchor anchor bolts bolts must must be be perfectly perfectly aligned aligned with with the the bolt bolt holes holes in in the the flange flange on on the the base base of of each each tower tower leg. leg. Only Only 1 1 / 16 / 16 tolerance tolerance exists exists between between each each anchor anchor bolt bolt and and its its mating mating bolt bolt hole hole diameter. diameter. A wooden wooden triangular triangular jig jig is is used used to to achieve achieve this this critical critical positioning. positioning.

5 4 A fourteen fourteen day day (minimum) (minimum) cure cure period period is is required required for for the the concrete. concrete.

6 5 The The tall tall Rohn Rohn SSV SSV free free standing standing truss truss tower tower is is delivered delivered to to the the construction construction site site in in sections. sections. Total Total weight weight ~1500 ~1500 pounds. pounds. The The tower tower is is made made of of (galvanized) (galvanized) steel steel tube tube construction construction with with flanges flanges on on each each section section and and angle angle diagonal diagonal cross cross bracings. bracings. The The diameter diameter of of steel steel tubes tubes increases increases toward toward the the base base of of the the tower. tower.

7 6 Assembly Assembly of of tower tower begins begins at at the the TOP TOP of of the the tower. tower. To To attach attach the the cross cross bracing, bracing, a drift drift pin pin aligns aligns the the holes holes and and will will lever lever (with (with force) force) the the parts parts into into alignment. alignment. Then Then a set set of of vice vice grips grips clamps clamps the the parts parts together. together. Then Then the the ½ ½ bolt bolt with with lock lock nut nut secures secures that that point. point.

8 7 The The tower tower is is assembled assembled on on its its side side and and later later erected erected by by use use of of a crane. crane. The The first first two two legs legs are are assembled assembled on on the the ground. ground. Then Then the the third third leg leg is is attached, attached, with with its its free free end end supported supported by by a scaffold. scaffold. During During assembly, assembly, wooden wooden shim shim blocks blocks are are used used to to help help level level the the first first two two legs legs along along the the uneven uneven ground. ground.

9 8 At At the the base base of of the the tower, tower, this this becomes becomes a largescalscale effort. large- effort. Meanwhile, Meanwhile, a pre-fabbed pre-fabbed power power room room appears appears on on site site which which will will house house the the Balance Balance of of Systems Systems (BOS; (BOS; electrical electrical controls). controls). Ladder Ladder pegs pegs are are bolted bolted onto onto the the third third leg. leg.

10 9 The The power power cable cable is is fed fed down down the the middle middle of of the the tower tower and and attached attached w/uv w/uv resistant resistant heavy heavy duty duty cable cable ties. ties. Bergey Bergey Excel Excel wind wind turbine turbine arrives arrives weighing weighing >1400 >1400 lbs. lbs. The The tail tail fin fin is is attached attached to to the the tail tail boom boom and and nuts nuts are are torqued torqued to to specification. specification.

11 10 The The powerhead powerhead is is then then attached. attached. This This is is accomplished accomplished by by lifting lifting up up the the top top of of the the tower tower (using (using crane) crane) and and resting resting it it atop atop a wooden wooden platform platform to to provide provide the the necessary necessary clearance. clearance. Then Then the the powerhead powerhead is is lifted lifted off off of of the the pallet pallet by by use use of of the the crane crane and and moved moved into into position. position. Locating Locating the the bolt bolt holes holes between between the the tower tower and and the the powerhead powerhead requires requires use use of of the the drift drift pin pin and and great great effort, effort, including including use use of of a jack jack to to position position the the third third leg leg into into alignment. alignment. Note:cross Note:cross braces braces are are only only finger finger tight tight at at this this point. point. The The tail tail boom, boom, weighing weighing >100 >100 lbs, lbs, is is attached. attached.

12 11 Tail Tail damper damper and and furling furling cable cable are are attached attached by by 2 2 cotter cotter pins. pins. Making Making electrical electrical connections connections to to the the powerhead: powerhead: Slip Slip rings rings from from Yaw Yaw shaft shaft carry carry AC AC voltage voltage to to terminal terminal block block in in wiring wiring box. box. Opening Opening the the nacelle nacelle allows allows manipulation manipulation of of damper damper angle angle (shown (shown as as long long steel steel pipe) pipe) The The crane crane (w/100 boom) (w/100 boom) is is readied readied for for lift. lift. At At up up the the high high tower, tower, two two legs legs are are attached attached with with slings slings for for pick pick up. up.

13 12 With With the the powerhead powerhead at at eye eye level, level, and and a 2x4 2x4 supporting supporting the the tail tail boom, boom, the the blades blades can can be be installed. installed. Pulltruded Pulltruded fiberglass fiberglass blades blades are are attached attached with with deformed deformed nuts nuts driven driven with with an an impact impact wrench. wrench. Hand Hand tightening tightening is is possible, possible, but but not not advised. advised. Final Final torque torque is is applied applied with with calibrated calibrated torque torque wrench. wrench. The The nosecone nosecone (spinner), (spinner), seen seen in in background, background, is is attached attached w/three w/three bolts bolts and and the the tower tower is is ready ready for for raising. raising.

14 SAFETY SAFETY FIRST. FIRST. The The tower tower is is lifted lifted slowly. slowly. Special Special attention attention and and planning planning are are required required to to ensure ensure that that the the wind wind turbine s turbine s blades blades and and tail tail have have sufficient sufficient clearance clearance from from the the crane. crane. The The crane s crane s boom boom is is initially initially positioned positioned to to ensure ensure that that boom boom movement movement is is TOWARD TOWARD crane s crane s center center of of gravity gravity during during tower tower raising raising so so that that crane crane does does not not extend extend beyond beyond its its balance. balance. 13

15 SAFETY SAFETY FIRST. FIRST. Radio Radio communication communication and and hand hand signals signals are are used used between between the the contractor contractor and and crane crane operator. operator. One One leg leg of of tower tower skids skids along along the the dirt dirt ground ground during during raising raising until until tower tower is is fully fully vertical vertical and and suspended suspended above above piers. piers. 14

16 15 Using Using a lever lever to to help help position position the the tower tower leg leg onto onto the the anchor anchor bolts. bolts. IT IT FITS! FITS! The The tower tower legs legs are are attached attached one one at at a time time to to their their anchor anchor bolts. bolts. Here Here the the flange flange is is secured secured between between double double nuts nuts on on the the anchor anchor bolts. bolts. Prior Prior to to the the tower tower raising, raising, the the level level of of all all three three legs legs was was predetermined predetermined and and set set within within 1 1 / 16 / 16 This This was was accomplished accomplished by by using using a water water level level to to fix fix the the location location of of the the bottom bottom nut nut on on the the anchor anchor bolt. bolt.

17 16 Furling Furling cable cable and and winch winch are are installed. installed. The The wind wind turbine turbine must must be be furled furled before before climbing climbing the the tower. tower. Tower Tower must must be be climbed climbed to to disconnect disconnect the the crane. crane. Safety Safety precautions precautions when when climbing climbing the the tower tower are are imperative. imperative.

18 17 Beginning Beginning at at the the top, top, all all cross cross bracing bracing bolts bolts (500 (500 +) +) need need to to be be torqued torqued to to specification specification and and supplied supplied a final final lock lock nut. nut. This This approach approach locks locks tower tower into into plum plum and and straight straight alignment. alignment. This This process process required required ~20 ~20 man man hours. hours. Plan Plan ahead ahead to to avoid avoid any any unnecessary unnecessary trips trips up up and and down down the the tower. tower. Tower Tower climbing climbing warrants warrants rest rest every every feet. feet. Sturdy Sturdy boots, boots, leather leather gloves, gloves, hard hardhat, hat, full full body body harness, harness, safety safety lanyard, lanyard, positioning positioning hooks hooks and and tethered tethered tools tools are are required. required.

19 18 Each Each leg leg is is grounded. grounded. Lightning Lightning arrester arrester is is installed installed on on wiring wiring box. box.

20 Inside Inside Power Power Room: Room: Balance Balance of of Systems Systems A-Transformer A-Transformer (STEPS WILD AC VOLTAGE (STEPS WILD AC VOLTAGE OUTPUT FROM BERGEY WIND OUTPUT FROM BERGEY WIND ALTERNATER FROM ~150V TO ALTERNATER FROM ~150V TO ~48V ) ~48V ) B-Bergey B-Bergey 48V 48V Regulator Regulator (RECTIFIES WILD AC TO (RECTIFIES WILD AC TO CONTROLLED DC and CONTROLLED DC and PREVENTS BATTERY PREVENTS BATTERY OVERCHARGE) OVERCHARGE) B C 19 C-Vanner C-Vanner Power Power Center Center DC DC Control Control Module Module (PROVIDES DC OVERCURRENT (PROVIDES DC OVERCURRENT PROTECTION) PROTECTION) AC AC Power Power Inverter Inverter (CONVERTS CONTROLLED DC (CONVERTS CONTROLLED DC TO CONTROLLED AC) TO CONTROLLED AC) AC AC Control Control Module Module (DISTRIBUTES CONTROLLED AC (DISTRIBUTES CONTROLLED AC TO LOADS (and GRID, if TO LOADS (and GRID, if available)) available)) D-48V D-48V NiCAD NiCAD Battery Battery Bank Bank A Photos Photos taken taken inside inside power power room room prior prior to to electrical electrical hookups. hookups. D

21 Tower 5 Power room Schematic Schematic of of electrical electrical power power system. system. 1.Bergey Excel R-48 wind generator wild AC output 2.Bergey tower wiring, 3 x #6 AWG MC Armored Cable 3.60A 600V 3-pole fusible, 3R rainproof disconnect with 3 x 60 Amp fuses and LA603 Arrestor 4.3 x # 6 AWG THHN in 2 PVC conduit, trenched 5.Step down transformer 6.Bergey VCS-10 controller (AC to DC) 7.Vanner RE VDC inverter with DC module and AC module includes DC over current protection and AC output breakers VDC battery Bank 9.AC circuits: outlets, light, fan, baseboard heater Third Sun Renewable Energy Title:Glacier Ridge one line schematic (740) Geoff@Third-Sun.Com Page: 1

22 Application Application for for Zoning Zoning Certificate Certificate is is through through Township.The Township.The most most common common zoning zoning issue issue is is height height restrictions; restrictions; permission permission to to exceed exceed normal normal limit limit may may require require a variance. variance. 21

23 Application Application & Approval Approval of of Building Building Permit Permit is is through through County. County. Permitting Permitting may may require require fee fee (usually (usually <$300), <$300), plot plot plan, plan, construction construction plans, plans, structural structural analysis analysis w/pe w/pe stamp, stamp, and and UL UL Listing Listing for for electrical electrical equipment. equipment. 22 NOT AVAIL

24 23 Federal Federal Aviation Aviation Administration Administration (FAA) (FAA) Requirements: Requirements: Usually, Usually, FAA FAA review review in in not not required required for for towers towers less less than than unless unless the the turbine turbine is is near near an an active active airport. airport.

25 Anatomy Anatomy of of the the Bergey Bergey Excel Excel Nacelle Powerhead Alternator 24 Tail Boom Tail Fin Spinner (nosecone) Start-up Start-up Wind Wind Speed: Speed: mph mph Type: Type: 3 3 Blade Blade Upwind Upwind Cut-in Cut-in Wind Wind Speed: Speed: 7 7 mph mph Rotor Rotor Diameter: Diameter: ft ft Rated Rated Wind Wind Speed: Speed: mph mph Overspeed Overspeed Protection: Protection: AUTOFURL AUTOFURL Rated Rated Power: Power: kw kw for for battery battery charging charging / / KW KW for for grid grid connection connection Furling Furling Wind Wind Speed: Speed: mph mph Gearbox: Gearbox: None, None, Direct Direct Drive Drive Max Max Wind Wind Speed: Speed: mph mph Generator: Generator: Permanent Permanent Magnet Magnet Alternator Alternator Output Output Form: Form: 3 3 phase phase AC, AC, Variable Variable Frequency Frequency Source: Bergey website

ASSEMBLY INSTRUCTIONS

ASSEMBLY INSTRUCTIONS WIND GENERATOR KIT Complete Set Including All Accessories 500 Watts rated at 12,5 m/s (= 28 mph) 6 Meter (= 20 ft.) Free-Standing Tower ASSEMBLY INSTRUCTIONS Contents WIND GENERATOR KIT Complete Set Including

More information

1KW WIND TURBINE. Welcome to the future, and our latest renewable energy products...

1KW WIND TURBINE.   Welcome to the future, and our latest renewable energy products... 1KW WIND TURBINE www.futurenergy.co.uk Welcome to the future, and our latest renewable energy products... Our rugged Horizontal Axis Wind Turbine range first came to market in Spring 2005. Since then we

More information

MAJOR SYSTEM FUNCTIONS

MAJOR SYSTEM FUNCTIONS MAJOR SYSTEM FUNCTIONS The ROTOR converts the aerodynamic energy in the wind to mechanical shaft torque. It also provides a lightning path from the blade tips to the main shaft. The GENERATOR converts

More information

Model: H kW. Features: 1. SCF Supercritical generator. 2. NSK bearings. 3. PLC integrated with Siemens module. 4. Low noise

Model: H kW. Features: 1. SCF Supercritical generator. 2. NSK bearings. 3. PLC integrated with Siemens module. 4. Low noise Model: H16.5-50kW Hummer 50kW wind turbine can be applied in both on-grid and off-grid systems. The output is three-phase AC and it can drive loads below 50kW. Features: 1. SCF Supercritical generator

More information

CONTENTS. Model & Parameter List 3. Installation Specification of Guyed Tower 5. Installation Specification of Tapered Tower 13

CONTENTS. Model & Parameter List 3. Installation Specification of Guyed Tower 5. Installation Specification of Tapered Tower 13 USER S MANUAL 1 CONTENTS Model & Parameter List 3 Installation Specification of Guyed Tower 5 Installation Specification of Tapered Tower 13 Configuration Specification of Batteries 15 Electric Wiring

More information

Operating & Installation Manual

Operating & Installation Manual Operating & Installation Manual (ZH1.5kw wind turbine system) Company Name:YUEQING ZONHAN WINDPOWER CO.,LTD. Address:NO.195,Chengxi Road,Yuecheng,Yueqing,Zhejiang,P.R.China Zip Code:325600 Tel:86-577-62529820

More information

BWC XL VDC Battery Charging System. XL.1 Wind Turbine PowerCenter Controller

BWC XL VDC Battery Charging System. XL.1 Wind Turbine PowerCenter Controller Version 2.2 August 2003 BWC XL.1 24 VDC Battery Charging System Owners Manual XL.1 Wind Turbine PowerCenter Controller Bergey Windpower Co. 2001 Priestley Ave., Norman, OK 73069 USA Telephone: (405) 364-4212

More information

About Wind Generators...

About Wind Generators... Quick Jumps: About Small Micro Hydro About... Wind energy as a resource... Good sites for wind power will have average wind speeds of 16 to 24 kph or more. There are locations on the coasts, prairies and

More information

ZheJiang SenWei Wind Turbine CO., Ltd

ZheJiang SenWei Wind Turbine CO., Ltd ZheJiang SenWei Wind Turbine CO., Ltd Add: 10th ZhanBei Road,Ping Ta Industrial Estate WenZhou City,ZheJiang Province Of China Tel:+86-577-68704548 Fax:+86-577-68706841 MOB: +86-15888784922 EMAIL:sales@windpowercn.com

More information

Installation Manual. For. Alumavator and Platinum. Vertical Installation. Elevator Boat Lifts

Installation Manual. For. Alumavator and Platinum. Vertical Installation. Elevator Boat Lifts Installation Manual For Alumavator and Platinum Vertical Installation Elevator Boat Lifts Page 2 Safety Precautions 1. Your boat lift is a heavy duty piece of equipment. It is important that all persons

More information

LOLER REGULATIONS INTRODUCTION

LOLER REGULATIONS INTRODUCTION LOLER REGULATIONS INTRODUCTION The key piece of legislation concerning the inspection of lifting equipment is Regulation 9 of LOLER - The Lifting Operations and Lifting Equipment Regulations 1998. LOLER

More information

HERCULES SIGN POST DIGGER DERRICK

HERCULES SIGN POST DIGGER DERRICK Introduction UTV International has manufactured a line of tracked carriers since 1992. In 1996, we integrated our first digger derrick onto a tracked carrier. Since then we have been engaged in a continual

More information

Wind Turbine Guidebook. For HYenergy HY-400, HY-600, HY-1000, HY-2000, HY-3000 Off-grid Models

Wind Turbine Guidebook. For HYenergy HY-400, HY-600, HY-1000, HY-2000, HY-3000 Off-grid Models WINDMAX Green Energy Wind Turbine Guidebook For HYenergy HY-400, HY-600, HY-1000, HY-2000, HY-3000 Off-grid Models Please write the serial number of your wind turbine on the front of this document before

More information

Installation Manual. For. High Speed Alumavator and Platinum. 10 and 23 Degree. Elevator Boat Lifts

Installation Manual. For. High Speed Alumavator and Platinum. 10 and 23 Degree. Elevator Boat Lifts Installation Manual For High Speed Alumavator and Platinum 10 and 23 Degree Elevator Boat Lifts Page 2 Safety Precautions 1. Your boat lift is a heavy duty piece of equipment. It is important that all

More information

Installation Manual. For. PWC 3000 Boat Lifts

Installation Manual. For. PWC 3000 Boat Lifts Installation Manual For PWC 3000 Boat Lifts Page 2 Safety Precautions 1. Your boat lift is a heavy duty piece of equipment. It is important that all persons that may operate this unit have read and understood

More information

FD21-50 GHREPOWER. Version: 3.0

FD21-50 GHREPOWER.   Version: 3.0 FD21-50 GHREPOWER ShanghaiGhrepower Green Energy Co Ltd Shanghai Ghrepower Green Energy Co., Ltd. Version: 3.0 1.0 Design Features Ghrepower s 50kW wind system is a gearless, direct drive permanent magnet

More information

wind turbine system For New Design

wind turbine system For New Design INSTRUCTION MANUAL WIND TURBINE 600W 1KW, 2KW, 3KW -10KW wind turbine system For New Design CONTENTS 1. SUMMARIZE... 2 2. TECHNICAL PARAMETER... 2 3. STRUCTURE COMPONENTS... 3 4. PACKING LIST... 4 5.

More information

Wind Turbine Generator System Safety and Function Test Report. Bergey Excel-S with Gridtek-10 inverter

Wind Turbine Generator System Safety and Function Test Report. Bergey Excel-S with Gridtek-10 inverter May 2003 NREL/EL-500-33963 Wind Turbine Generator System Safety and Function Test Report for the Bergey Excel-S with Gridtek-10 inverter by National Wind Technology Center National Renewable Energy Laboratory

More information

Owners Manual. BWC XL.1 24 VDC Battery Charging System. XL.1 Wind Turbine PowerCenter Controller

Owners Manual. BWC XL.1 24 VDC Battery Charging System. XL.1 Wind Turbine PowerCenter Controller Version 1.1 January 2001 BWC XL.1 24 VDC Battery Charging System Owners Manual XL.1 Wind Turbine PowerCenter Controller Bergey Windpower Co., Inc. 2001 Priestley Ave., Norman, OK 73069 USA Telephone: (405)

More information

Windtura 750 Owner s Manual. (No slip ring version)

Windtura 750 Owner s Manual. (No slip ring version) Windtura 750 Owner s Manual (No slip ring version) Rev 1.0 Copyright 2011 1 Table of Contents A. Introduction B. Warranty C. Parts list D. Installation Warnings E. Technical Specifications F. Windtura

More information

Contents INTRODUCTION... 2 CHECK YOU HAVE RECEIVED... 4 WHAT YOU WILL NEED...4 TECHNICAL CHARACTERISTICS...5 WIRING DIAGRAMES...6 CABLES...

Contents INTRODUCTION... 2 CHECK YOU HAVE RECEIVED... 4 WHAT YOU WILL NEED...4 TECHNICAL CHARACTERISTICS...5 WIRING DIAGRAMES...6 CABLES... Contents Page INTRODUCTION... 2 CHECK YOU HAVE RECEIVED... 4 WHAT YOU WILL NEED...4 TECHNICAL CHARACTERISTICS...5 WIRING DIAGRAMES...6 CABLES...6 BATTERY...7 CHARGE CONTROLLER...8 FUSE...8 TOWERS...8 INSTALLATIONS...9

More information

Installation Manual. For. Trident Boat Lifts

Installation Manual. For. Trident Boat Lifts Installation Manual For Trident Boat Lifts Page 2 Safety Precautions 1. Your boat lift is a heavy duty piece of equipment. It is important that all persons that may operate this unit have read and understood

More information

ADMINISTRATIVE PRACTICES MANUAL

ADMINISTRATIVE PRACTICES MANUAL SAFETY MANUAL : 1.0 Scope and Application This policy is intended to prescribe rules and establish minimum requirements for the care, and use of the common types of ladders, in order to insure safety under

More information

FREE STANDING WORK STATION JIB CRANE

FREE STANDING WORK STATION JIB CRANE SECTION 14661 FREE STANDING WORK STATION JIB CRANE ***** Gorbel, Inc. manufacturers a broad range of material handling cranes including monorail, bridge, gantry, and jib cranes. Numerous work station and

More information

FOLD-A-WAY BUMPER CRANES

FOLD-A-WAY BUMPER CRANES FOLD-A-WAY BUMPER CRANES ATERIAL HANDLING SOLUTIONS SINCE 1982 Much More Than Just A Crane! CRANE HITCH WINCH BUMPER MAN-LIFT WESTERN MULE CRANES HELPING YOU GET THE JOB DONE NOW YOU SEE IT... SINCE 1982

More information

K2 Wind Community Liaison Committee Meeting #2 Wednesday, May 28, 2014

K2 Wind Community Liaison Committee Meeting #2 Wednesday, May 28, 2014 K2 Wind Community Liaison Committee Meeting #2 Wednesday, May 28, 2014 K2 Wind Background The K2 Wind Power Project is a 270 megawatt (MW) wind project being developed in the Township of Ashfield-Colborne-Wawanosh

More information

K L E I N W I N D K R A F T kleinwind.at

K L E I N W I N D K R A F T kleinwind.at K L E I N W I N D K R A F T kleinwind.at EDITORIAL Dear Ladies and Gentleman! Wind power is known as a clean and environment friendly energy that leaves no hazardous waste or CO ². Wind energy is an ideal

More information

Support and management of this policy. Ensure policy is adhered to by all employees. Follow requirements contained in this policy.

Support and management of this policy. Ensure policy is adhered to by all employees. Follow requirements contained in this policy. 1.0 Scope and Application This policy is intended to prescribe rules and establish minimum requirements for the care, and use of the common types of ladders, in order to insure safety under normal conditions

More information

400 Watt WIND TURBINE

400 Watt WIND TURBINE 400 Watt WIND TURBINE User s Manual Congratulations on your Coleman solar product purchase. This product is designed to the highest technical specifications and standards. It will supply years of maintenance

More information

SolarMill SM1-1P, SM1-2P, SM2-3P, SM2-5P, SM2-6P. User manual. Draft. SM1 - Product shown may vary slightly from specific model shipped

SolarMill SM1-1P, SM1-2P, SM2-3P, SM2-5P, SM2-6P. User manual. Draft. SM1 - Product shown may vary slightly from specific model shipped SolarMill SM1-1P, SM1-2P, SM2-3P, SM2-5P, SM2-6P User manual SM1 - Product shown may vary slightly from specific model shipped Version 2.01 REV 11.3.13 All rights reserved. WindStream Technologies Table

More information

INSTALLATION MANUAL 20kW Low-Speed

INSTALLATION MANUAL 20kW Low-Speed INSTALLATION MANUAL 20kW Low-Speed Contents 1 Statement from A&C Green Energy 4 2 Summary 5 2.1 Information 5 2.2 Mark Illustrations 5 2.3 Applications for Use 5 2.4 Structure and Main Property 6 2.5 Technical

More information

PRELIMINARY METHOD OF STATEMENT

PRELIMINARY METHOD OF STATEMENT PRELIMINARY METHOD OF STATEMENT LID Energy 30 MW Wind Turbine Erection Project Belen / TURKEY Table of Contents 1. Cranes...... page 3 2. Tackle Check List....... page 3 3. Turbine Details.... page 3 4.

More information

STEP LADDER ALUMINIUM

STEP LADDER ALUMINIUM STEP LADDER ALUMINIUM STEP LADDER ALUMINIUM with or without HANDLE Steel Step Ladder Light Grey 6-8 steps W D H h 3-6 steps Features: Light weight Easy to use 3-5 steps 3-6 steps 2-3 steps Certificate

More information

Structure of Wind Supply Chain Onshore to Offshore. Ed Weston Director, GLWN Copyright 2012 GLWN A WIRE-Net Initiative

Structure of Wind Supply Chain Onshore to Offshore. Ed Weston Director, GLWN Copyright 2012 GLWN A WIRE-Net Initiative Structure of Wind Supply Chain Onshore to Offshore Ed Weston Director, GLWN eweston@glwn.org FIND Connections Company name WIND Classification Component Families Radius Search Active Suppliers Almost 1600

More information

GET GROUNDED. Renewable Energy System Grounding Basics

GET GROUNDED. Renewable Energy System Grounding Basics GET GROUNDED Renewable Energy System ing Basics by Christopher Freitas ASK TEN RENEWABLE ENERGY INSTALLERS ABOUT SYSTEM GROUNDING and you ll likely get ten different opinions as to what the National Electrical

More information

HM WIND TURBINE. Operation Manual. **Please read the manual carefully before using **

HM WIND TURBINE. Operation Manual. **Please read the manual carefully before using ** HM4.0-3000 WIND TURBINE Operation Manual **Please read the manual carefully before using ** - 1 - HM4.0-3KW operation manual.doc 1. The aim of Application Use wind energy to generate electricity and charge

More information

Contractors Guide Central Inverter System Installation

Contractors Guide Central Inverter System Installation Contractors Guide Central Inverter System Installation Step By Step Procedures 3,000 Watt/VA Vertical (Stacked) and Horizontal (Side by Side) 5 Step Installation 1. Mounting the Cabinet 2. Install / Connect

More information

LIFT TRUCKS FOR EVERY APPLICATION

LIFT TRUCKS FOR EVERY APPLICATION LIFT TRUCKS FOR EVERY APPLICATION Container ports and terminals Intermodal and barge handling Steel and aluminum Mining General manufacturing Pulp & paper, wood Automotive Wind power Oil & gas Nuclear

More information

2,600W Wind/Solar Hybrid System HY-W2S6

2,600W Wind/Solar Hybrid System HY-W2S6 2,600W Wind/Solar Hybrid System HY-W2S6 Performance: 160-400 AC Kilowatt-hours (kwh's) per month (depending on wind and solar resources) Recommended for: Typical off-grid homes, schools, clinics, etc.

More information

ABB Wind Power Solution

ABB Wind Power Solution Feng Li, Wind ISI, CNABB, November, 2016 ABB Wind Power Solution November 13, 2016 Slide 1 ABB deliveries from A to Z into the wind industry Wind power generation, transmission and integration, control

More information

Installation and Owner s Manual

Installation and Owner s Manual Installation and Owner s Manual LAKOTA Turbine - Land, Marine, and M1 Models Distributed Worldwide by: Alternative Energy Store AEROMAG CORPORATION Version 2.42 WARNING The LAKOTA Wind Turbine can be easily

More information

Now There is a New Source of Energy Independence Your Backyard.

Now There is a New Source of Energy Independence Your Backyard. Now There is a New Source of Energy Independence Your Backyard. Renewable Energy Company dedicated to providing you with affordable products and services to save money on energy over the long term. Services

More information

Wind Energy Technologies

Wind Energy Technologies Wind Energy Technologies Wind Energy Technician This Green Collar Zone workstation will teach you the basic principles of wind power, as you acquire skills by performing hands-on activities. No prior knowledge

More information

1. Cranes. 3. Hazardous Chemicals. 4. Signs. 2. Trenching and Excavations

1. Cranes. 3. Hazardous Chemicals. 4. Signs. 2. Trenching and Excavations A Safe Operation Safety Tips for Heavy Construction 1. Cranes Cranes are a common piece of equipment on heavy construction jobsites. Always perform a walk around inspection before and after each shift

More information

Bergey Wind Power XL.1

Bergey Wind Power XL.1 Bergey Wind Power XL.1 Hub height 100-1 (30.5m) Lower anem 60 (18.3m) *changed from 20m on 5/31/05 BJS to reduce vibration Upper anem & vane 91.8 (28m) The Bergey XL.1 was installed by the SWI crew on

More information

7 Hazard assessment 8 Worker participation 9 Hazard elimination and control

7 Hazard assessment 8 Worker participation 9 Hazard elimination and control This document is a guideline only. Employers have a responsibility of assessing all applicable occupational health and safety legislation, for the tasks they are performing. Employers in this industry

More information

GOLDWIND S48/750 (50Hz) Technical Specifications

GOLDWIND S48/750 (50Hz) Technical Specifications GOLDWIND S48/750 (50Hz) Technical Specifications Content 1. GOLDWIND S48/750 General Overview page 3-5 2. Nacelle - Major Components Overview page 6 8 3. Gearbox & Main Shaft page 9-10 4. Brake System

More information

2017 CATALOG East Main Street Mesa, AZ

2017 CATALOG East Main Street Mesa, AZ 01 2017 CATALOG 9502 East Main Street Mesa, AZ 85207 888 964.1488 480 986.1488 sales@ruralelectric.com www.ruralelectric.com 02 ABOUT US Since 1964 Rural Electric has been providing electrical contracting

More information

Energy.ca. www. Energy.ca. www. .GreenerEnergy.

Energy.ca.   www. Energy.ca. www. .GreenerEnergy. www Energy.ca www.greener.greenerenergy www Energy.ca www.greener.greenerenergy sales@livenergysolutions.com Info@LivEnergySolutions.com Air-X 400 watt wind generator, 12V Air-X 400 watt wind generator,

More information

Engineered Lifting Technologies Designer and Manufacturer of Custom Lifting Solutions

Engineered Lifting Technologies Designer and Manufacturer of Custom Lifting Solutions ISO 9001:2008 Registered with Design ENGINEERED LIFTING TECHNOLOGIES REGISTERED with DESIGN Engineered Lifting Technologies Designer and Manufacturer of Custom Lifting Solutions AHB-20-120-48 BEAMS ASB

More information

Installation Manual. BWC EXCEL 10 Wind Turbine and Tilt-up Lattice Towers. Part # MANTU Revision 2.2 Preliminary March 2016

Installation Manual. BWC EXCEL 10 Wind Turbine and Tilt-up Lattice Towers. Part # MANTU Revision 2.2 Preliminary March 2016 Installation Manual BWC EXCEL 10 Wind Turbine and Tilt-up Lattice Towers Part # MANTU Revision 2.2 Preliminary March 2016 Bergey Windpower Co. 2200 Industrial Blvd. Norman, OK 73069 USA TEL: 405-364-4212

More information

SunWize SW and OEM Series Solar Modules GENERAL INSTALLATION & USER GUIDE

SunWize SW and OEM Series Solar Modules GENERAL INSTALLATION & USER GUIDE SunWize SW and OEM Series Solar Modules GENERAL INSTALLATION & USER GUIDE Introduction This guide contains application and user safety information you should become familiar with before using your SW/OEM

More information

Airflo MANUFACTURING CO., INC.

Airflo MANUFACTURING CO., INC. Airflo MANUFACTURING CO., INC. 365 UPPER OAKWOOD AVE, ELMIRA NY 14903 PHONE: 607-733-8284 / FAX: 607-733-0587 OPERATOR & PARTS MANUAL PSV-8L ELECTRIC SPREADER Visit our website at www.air-flo.com Contents

More information

ATLAS 2000 SINGLE LINE HYDRAULIC HOIST

ATLAS 2000 SINGLE LINE HYDRAULIC HOIST ATLAS 2000 SINGLE LINE HYDRAULIC HOIST OPERATORS INSTRUCTION MANUAL Keep this Manual with the Atlas 2000 Hoist at all times. This will allow new users to read it before operating the Hoist. It is the Atlas

More information

Product Specification Guide. Title: Southern States 72 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

Product Specification Guide. Title: Southern States 72 kv RLSwitcher Vertical Interrupter Style Reactor Switcher TABLE OF CONTENTS PAGE 1.0 SCOPE... 2 2.0 STANDARDS... 2 3.0 DESIGN REQUIREMENTS... 2 3.01 Service Conditions... 2 3.02 Ratings... 3 3.03 Interrupter... 3 3.04 SF6 Gas System... 4 3.05 Terminal Pads...

More information

WIELAND-DAVCO CORPORATION CRITICAL LIFT PERMIT. Subcontractor: Subcontractor Lift Supervisor: (This individual must be present during the lift)

WIELAND-DAVCO CORPORATION CRITICAL LIFT PERMIT. Subcontractor: Subcontractor Lift Supervisor: (This individual must be present during the lift) WIELAND-DAVCO CORPORATION CRITICAL LIFT PERMIT Section 1: Approvals and Documentation A. Identification Subcontract Number: Location: Lift Identification Name: Date of Lift: Time: Lift Description: B.

More information

Installation Instructions

Installation Instructions 9049 Tyler Blvd. Mentor, Ohio 44060 Phone (440) 974-8888 Fax (440) 974-0165 Toll-Free Fax 800-841-8003 saltdogg.com Installation Instructions Salt Dogg Spreader Hopper Poly Electrical 2.0 cubic yards Serial

More information

Operator s Manual. 2010, 2015, 2020, 2025 Material Lifts

Operator s Manual. 2010, 2015, 2020, 2025 Material Lifts Operator s Manual 2010, 2015, 2020, 2025 Material Lifts April 2005! Before operating this lift, read and understand this Operator s Manual. Become familiar with the potential hazards of this unit. Call

More information

Wind Generator. FSH400 Instruction Manual. Serial number:

Wind Generator. FSH400 Instruction Manual. Serial number: Wind Generator FSH400 Instruction Manual Serial number: 1. Introduction: This manual contains installation and safety information for the 400 Watt Wind Turbine. The information in this manual is believed

More information

Installation Manual. For. Alumavator / Platinum Boathouse Lifts

Installation Manual. For. Alumavator / Platinum Boathouse Lifts Installation Manual For Alumavator / Platinum Boathouse Lifts Page 2 Safety Precautions 1. Your boat lift is a heavy duty piece of equipment. It is important that all persons that may operate this unit

More information

Table of Contents. Chapter 2 Safety Fundamentals for Bridge Inspectors. Methods of Access Introduction

Table of Contents. Chapter 2 Safety Fundamentals for Bridge Inspectors. Methods of Access Introduction Table of Contents Chapter 2 Safety Fundamentals for Bridge Inspectors 2.5 Methods of Access... 2.5.1 2.5.1 Introduction... 2.5.1 2.5.2 Types of Access Equipment... 2.5.1 Ladders... 2.5.1 Rigging... 2.5.2

More information

Switchgear Skid, C1192

Switchgear Skid, C1192 CUSTOM SOLUTIONS 15kV Modular Stairs stored on floor in front of battery bay Ground grid stored on front tongue of trailer Stairs deployed for unit access Storage box for fencing materials and other parts

More information

Product Specification Guide. Title: Southern States 362 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

Product Specification Guide. Title: Southern States 362 kv RLSwitcher Vertical Interrupter Style Reactor Switcher TABLE OF CONTENTS PAGE 1.0 SCOPE... 2 2.0 STANDARDS... 2 3.0 DESIGN REQUIREMENTS... 2 3.01 Service Conditions... 2 3.02 Ratings... 2 3.03 Interrupter... 3 3.04 SF6 Gas System... 4 3.05 Terminal Pads...

More information

Installation Instructions Table of Contents

Installation Instructions Table of Contents Installation Instructions Table of Contents Pre- Installation of Garage Storage Lift 2 Layout the Garage Storage Lift 3 Installing the strut Channels 3 Install the Drive Assembly 5 Install the Drive Shaft

More information

Model: H4.6-3kW / H6.4-5kW / H8.0-10kW / H9.0-20kW

Model: H4.6-3kW / H6.4-5kW / H8.0-10kW / H9.0-20kW Model: H4.6-3kW / H6.4-5kW / H8.0-10kW / H9.0-20kW Hummer 3kW / 5kW / 10kW / 20kW wind turbines can be applied in both on-grid and off-grid systems. I. Features: 1. SCF Supercritical generator Hummer s

More information

3. WIRING AND INSTALLATION PROCEDURES 3.1 System wiring diagrams 4.LOCATION SELECTION 5. TOWER 6.1 SINGLE WIND GENERATOR 6.2CONTROLLER WIRING 6.

3. WIRING AND INSTALLATION PROCEDURES 3.1 System wiring diagrams 4.LOCATION SELECTION 5. TOWER 6.1 SINGLE WIND GENERATOR 6.2CONTROLLER WIRING 6. 4 4 4 4 5 3. WIRING AND INSTALLATION PROCEDURES 3.1 System wiring diagrams 4.LOCATION SELECTION 5. TOWER 6.1 SINGLE WIND GENERATOR 6.2CONTROLLER WIRING 6.3 INSTALLATION OPERATION 6.4 ATTACHING TO POLE

More information

Instruction Manual. SaltDogg Spreader Hopper Poly Electrical 0.65 cubic yards. Table of Contents. General Information. Vehicle Requirements: WARNING

Instruction Manual. SaltDogg Spreader Hopper Poly Electrical 0.65 cubic yards. Table of Contents. General Information. Vehicle Requirements: WARNING SaltDogg Spreader Hopper Poly Electrical 0.5 cubic yards Instruction Manual Table of Contents General Information... Warranty Information... Safety Precautions... Installation Instructions... -3 Spreader

More information

LeTourneau Technologies JC-52KP Jib Crane Specifications, 3/11. Note: Optional equipment may be shown in photo.

LeTourneau Technologies JC-52KP Jib Crane Specifications, 3/11. Note: Optional equipment may be shown in photo. JC-52KP Jib Crane Standard Boom Length: 120' (36.58 m) Lift Capacity: 52,000 lbs. (23,587 kgs) Optional Boom Length: 100' (30.48 m) Lift Capacity: 56,000 lbs. (25,402 kgs) Optional Boom Length: 150' (45.72

More information

T 775. truck crane 75 ton capacity. range diagram & lifting capacities. Range Diagram (40' - 126' boom)

T 775. truck crane 75 ton capacity. range diagram & lifting capacities. Range Diagram (40' - 126' boom) T 7 truck crane ton capacity range diagram & lifting capacities DEFLECTIONS NOT SHOWN 6' - 9" 4' - 8" DIMENSIONS ARE FOR LARGEST FACTORY FURNISHED HOOK BLOCK AND HOOK & BALL, WITH ANTI-TWO BLOCK ACTIVATED

More information

LADDERS. Fiberglass Stepladder CSA Grade 1 - RED. Fiberglass Stepladder CSA Grade 1 - YELLOW. Wood Stepladder - 89 Series w/black End Caps

LADDERS. Fiberglass Stepladder CSA Grade 1 - RED. Fiberglass Stepladder CSA Grade 1 - YELLOW. Wood Stepladder - 89 Series w/black End Caps Fiberglass Stepladder CSA Grade 1 - RED Fiberglass Stepladder CSA Grade 1 - YELLOW Non-conducive Fiberglass Rails Double Riveting on each step Heavy duty molded plastic top Back-up Plates Reinforce all

More information

Section 13. Tail Rotor Drive. RotorWay International A600 TALON Construction Manual. Section 13. Page A

Section 13. Tail Rotor Drive. RotorWay International A600 TALON Construction Manual. Section 13. Page A RotorWay International Page A Tail Rotor Drive Procedures covered in this section: Install driveshafts and gearboxes; install drive belt and tensioner; fabricate and install tail rotor pitch actuator arms;

More information

Liftmoore Electric & Hydraulic Cranes. One Year from in service date. Date & I.D. of Price List

Liftmoore Electric & Hydraulic Cranes. One Year from in service date. Date & I.D. of Price List #250-109 STATE OF MINNESOTA PRICING PAGE ADDENDUM 3 5-11-2011 Vendor Name:, Inc Contact Person: Jim McLaughlin Street Address: 3804 Highway 75 North P.O. Box: 336 City, State, Zip Moorhead, MN 56561-0336

More information

Valley. Center Pivots. reliable. durable. precise. advanced. responsive

Valley. Center Pivots. reliable. durable. precise. advanced. responsive Valley Center Pivots reliable durable precise advanced responsive Durable Valley Structures Designed for Long Life When making decisions that affect your yields and bottom line, look to Valmont Irrigation

More information

SPECIAL SPECIFICATION 1788 Surveillance Cabinet

SPECIAL SPECIFICATION 1788 Surveillance Cabinet 1993 Specifications CSJ 2266-02-095 SPECIAL SPECIFICATION 1788 Surveillance Cabinet 1. General. This Item shall govern the furnishing and installation of Surveillance Cabinet to include the installation

More information

ORDERLY NEGOTIATED SALE MICON M1500 WIND TURBINES EQUIPMENT CATALOG AUCTION DIVISION Rochester, Minnesota

ORDERLY NEGOTIATED SALE MICON M1500 WIND TURBINES EQUIPMENT CATALOG AUCTION DIVISION Rochester, Minnesota ORDERLY NEGOTIATED SALE www.maascompanies.com 4- MICON M1500 WIND TURBINES EQUIPMENT CATALOG AUCTION DIVISION 507.285.1444 Rochester, Minnesota 10 MICON A/S - WIND TURBINE, TOWER MOUNTED: Consisting of

More information

Model Description Vac. Max rating Pedestal Only: 36 Utility Pedestal W/O Disconnect General Duty Series:

Model Description Vac. Max rating Pedestal Only: 36 Utility Pedestal W/O Disconnect General Duty Series: MAPA Products MPD-XX / Pedestal Disconnect 30, 60, 100 amp February 2014 Pedestal Disconnect Installation Instructions Parts List MAPA Products Fusible Rainproof Pedestal Mounted Safety Switch provides

More information

GENERAL SPECIFICATIONS

GENERAL SPECIFICATIONS GENERAL SPECIFICATIONS The GP Yonval 40-16 is designed to generate high levels of energy, in accordance with the IEC 61400-2 standards and manufactured with reliable European components. The variable speed

More information

APPENDIX B. POTENTIAL CONSTRUCTION EQUIPMENT

APPENDIX B. POTENTIAL CONSTRUCTION EQUIPMENT . POTENTIAL CONSTRUCTION EQUIPMENT Table B-1. Alternative 1 (Options A and B) and Alternative 3 Alternative 1 (Options A and B) and Alternative 3 Overhead Transmission Line and Poles Removal of conductors

More information

Missouri Wind and Solar Wind Turbine Installation Instructions

Missouri Wind and Solar Wind Turbine Installation Instructions Introduction Missouri Wind and Solar Wind Turbine Installation Instructions 1. Thank you for purchasing a Missouri Wind and Solar wind turbine system. Through process improvement, customer feedback, and

More information

Latest References for Ladders

Latest References for Ladders Code of Practice Prevention of Falls at Workplaces Fixed Ladders Ladder and tower safety systems should be installed on fixed ladders (for example, rung ladders). The ladder cages in fixed ladders have

More information

Renewable Energy Systems

Renewable Energy Systems Renewable Energy Systems 8 Buchla, Kissell, Floyd Chapter Outline Wind Turbine Control 8 Buchla, Kissell, Floyd 8-1 PITCH AND YAW CONTROL 8-2 TURBINE ORIENTATION 8-3 DRIVE TRAIN GEARING AND DIRECT DRIVE

More information

BLAZER 9000 LUBE LIFT OPERATOR AND PARTS MANUAL

BLAZER 9000 LUBE LIFT OPERATOR AND PARTS MANUAL BLAZER 9000 LUBE LIFT OPERATOR AND PARTS MANUAL Blazer 9000 Lube Lift Operator s Manual Note: Instructions must be read thoroughly before installing, operating, or maintaining the lift. Devon Lube Center

More information

Wind-Electric Systems

Wind-Electric Systems -Electric Systems Ian Woofenden 005 Ian Woofenden -electric systems may be the most captivating of the three main renewable electricity technologies. Most of us just love to watch a wind turbine spin.

More information

brighter future take charge of your family s energy future harvest power year-round, night and day with a wind+solar hybrid system from Pika.

brighter future take charge of your family s energy future harvest power year-round, night and day with a wind+solar hybrid system from Pika. smarter power for a brighter future harvest power year-round, night and day w h i s p e r- q u i e t take charge of your family s energy future with a wind+solar hybrid system from Pika. (207) 887-9105

More information

SAFE WORK PROCEDURE LOCATION OF WORK WRITTEN BY: APPROVED BY: DATE: LAST REVISION

SAFE WORK PROCEDURE LOCATION OF WORK WRITTEN BY: APPROVED BY: DATE: LAST REVISION Page 1 of 5 LOCATION OF WORK WRITTEN BY: APPROVED BY: DATE: LAST REVISION All Schools Lorie Carriere Jason Graham Donna Hancox Gordon Howe April 27, 2010 March 8, 2017 HAZARDS PRESENT Sun burns Muscle

More information

Star Swivel-Arm Hoist Installation and Operating Instructions

Star Swivel-Arm Hoist Installation and Operating Instructions Star Swivel-Arm Hoist Installation and Operating Instructions Conveying & Hoisting Solutions P/L ABN 78 6 7. Purpose of Equipment Star Swivel-Arm Hoists are intended for the transport of materials. Star

More information

User Guide. BreezePro TPW-400DT 12/24V 400W Wind Turbine A. NOTICE. B. SAFETY PRECAUTIONS (Important) C. About BreezePro

User Guide. BreezePro TPW-400DT 12/24V 400W Wind Turbine A. NOTICE. B. SAFETY PRECAUTIONS (Important) C. About BreezePro A. NOTICE User Guide BreezePro TPW-400DT 12/24V 400W Wind Turbine 1. This information is believed to be reliable; however, We assume no responsibility for inaccuracies or omissions. The user of this information

More information

SEI Overview - Wind Power

SEI Overview - Wind Power SEI Overview - Wind Power Carbondale/Paonia Colorado www.solarenergy.org WHY WIND (renewables)? Gain energy independence from fossil fuels Ease demand on the power grid Reduce vulnerability to volatile

More information

Commercial Hopper Tanks (CHT)

Commercial Hopper Tanks (CHT) Commercial Hopper Tanks (CHT) Total Value. Total Systems. NCHT & FCHT Series The right tank for the right job. Commercial hopper tanks are typically used in applications where routine clean out is required,

More information

SPINKS SCALES ROOSTER SCALES MODELS: 250 # 350 # 600 # INSTRUCTIONS/OPERATOR S MANUAL For. JANUARY, 2000 Manual No (Rev.

SPINKS SCALES ROOSTER SCALES MODELS: 250 # 350 # 600 # INSTRUCTIONS/OPERATOR S MANUAL For. JANUARY, 2000 Manual No (Rev. SPINKS SCALES INSTRUCTIONS/OPERATOR S MANUAL For ROOSTER SCALES MODELS: 250 # 350 # 600 # JANUARY, 2000 Manual No. 003123 (Rev. 1) TABLE OF CONTENTS HANGING SCALES...Pages 3-4 CONTROL BOX INSTALLATION...

More information

ELECTRIC HOIST DC12V. Operating Instructions

ELECTRIC HOIST DC12V. Operating Instructions ELECTRIC HOIST DC12V Operating Instructions 1 Safety Precautions 1. Read the instructions carefully; understand the structure and performance of the machine. 2. Check the vehicle battery to make sure it

More information

HEALTH AND SAFETY MANUAL

HEALTH AND SAFETY MANUAL HEALTH AND SAFETY MANUAL Title: Ladders (Portable & Fixed) Approved by: Greg Savoy Rev. 4/1/08 1 Purpose/Scope: This section is intended to prescribe rules and establish minimum requirements for the construction,

More information

STANDARD 25G GUYED TOWER. includes REV. F & REV. G GENERAL USE FEATURES. Phone (309) Fax (309) The Industry Standard

STANDARD 25G GUYED TOWER. includes REV. F & REV. G GENERAL USE FEATURES. Phone (309) Fax (309) The Industry Standard G GUYED TOWERS 25G STANDARD 25G GUYED TOWER ROHN 25G The first. The original. includes REV. F & REV. G 25G GENERAL USE The 25G is available in the standard 0 section length and a 7 length which is UPS

More information

INTER PLANT STANDARD STEEL INDUSTRY

INTER PLANT STANDARD STEEL INDUSTRY INTER PLANT STANDARD STEEL INDUSTRY IPSS SPECIFICATION FOR ac CRANE (Hoist and Winches) DUTY SQUIRREL CAGE INDUCTION MOTORS (Fourth Revision) BASED ON IS 325:1996 Formerly: IPSS:1-03-004-05 0. FOREWORD

More information

LINK-BELT MODEL HTC TON CAPACITY RANGE DIAGRAM. LIFTING CHARTS - Hydraulic Truck Cranes

LINK-BELT MODEL HTC TON CAPACITY RANGE DIAGRAM. LIFTING CHARTS - Hydraulic Truck Cranes LIFTING CHARTS - Hydraulic Truck Cranes LINK-BELT MODEL HTC-840-40 TON CAPACITY RANGE DIAGRAM NOTE: and fly and jib geometry shown are for unloaded condition and machine standing level on firm supporting

More information

FBD-NT Press Brake Installation Guide

FBD-NT Press Brake Installation Guide FBD-NT Press Brake Installation Guide Summary...2 Environmental conditions...2 Power supply...2 Machine installation...3 Location...4 Carrying...5 Using a crane...5 Using rollers...6 Foundation...7 Cleaning...7

More information

Wind Turbine Generator System Safety and Function Test Report. Atlantic Orient 15/50 Wind Turbine

Wind Turbine Generator System Safety and Function Test Report. Atlantic Orient 15/50 Wind Turbine June 23 NREL/EL-5-34382 Wind Turbine Generator System Safety and Function Test Report for the Atlantic Orient 15/5 Wind Turbine by National Wind Technology Center National Renewable Energy Laboratory 1617

More information

Services. Rental Equipment RENTAL DIVISION PRODUCT LINES. LOAD RESTRAINTS Load Binders (Lever & Ratchet) Truck Tie-down Assemblies Boomer Chains

Services. Rental Equipment RENTAL DIVISION PRODUCT LINES. LOAD RESTRAINTS Load Binders (Lever & Ratchet) Truck Tie-down Assemblies Boomer Chains RENTAL DIVISION PRODUCT LINES In a continuing effort to give the customer the opportunity to get an assortment of equipment, services and products from one supplier, our rental division was established

More information

Some admonitions you must know before using DS600

Some admonitions you must know before using DS600 DS600 USER S MANUAL Some admonitions you must know before using DS600 This user s manual has been carefully checked by our engineers. Users need to observe with the local law, regulation and the permission

More information

FORKS & SPEARS. Endless Attachments FORKS & RELATED ATTACHMENTS

FORKS & SPEARS. Endless Attachments FORKS & RELATED ATTACHMENTS Endless Attachments Change the attachment to change the machine. Manual tasks traditionally done by many people are now carried out by Dieci rough terrain telescopic handlers. One skilled operator with

More information