SELECTOR GUIDE POTTING & ENCAPSULATING COMPOUNDS

Size: px
Start display at page:

Download "SELECTOR GUIDE POTTING & ENCAPSULATING COMPOUNDS"

Transcription

1 SELECTOR GUIDE POTTING & ENCAPSULATING COMPOUNDS Epoxyset s potting and encapsulating compounds are fmulated f the demanding high perfmance requirements of the electrical and electronic industries f such applications as the potting of electronic ballasts, capacits, power supplies, relays and other devices with high heat dissipation requirements. Our Flame retardant and High products provide higher flame retardancy, increased high-voltage insulating characteristics and improved thermal management over currently available materials, significantly reducing the operating temperature of potted internal components - thus extending the life cycle of electrical devices. Applications: Circuit Board Protection - Sensitive electronic components Potting telecommunications equipment cut-out switches Potting ballasts, pumps, surge suppresss, connects, switches, relays, coils, transfmers, power supplies, resists, solenoids, proximity switches, transists, senss, power line filters, timers, etc

2 LOW EXPANSION - EPOXY COMPOUNDS Pot 25 C Mix Viscosity EC-1002 Black 100/14 1 hr EC-1004 Black 100/12 1 hr hrs 2 70 C 24 hrs 2 70 C Glass Transition Temp (Tg) CTE below Tg (in/in/10-6 ) 1.55 D C C C 1.55 D C C EC-1021 Black 100/25 >8 hrs C 1.72 D C C EC-1024 Black 100/5 1-2 hrs hrs 1.7 D C C EC Black 100/5 4 hrs C 1.9 D C EC-1026 Black 100/25 >8 hrs D EC-1027 Black 100/10 >4 hrs 39, C 1.76 D C C EC-1031 Black 100/6 ½ hr 6000 EC-1051 Black 100/6 ½ hr 30,000 EC-1052 Black 100/25 >8 hrs 4000 EC- 1052LV 24 hrs 24 hrs D C D C C 1.7 D Black 100/10 >3 hrs C 1.7 D C C EC-1082 Black 100/8 >4 hrs 70 C C 1.82 D C

3 THERMALLY CONDUCTIVE - EPOXY COMPOUNDS Mix Ratio by weight Pot life Mix Viscosity Glass Transition Temp (Tg) CTE below Tg (in/in/10-6 ) EC-1006 Black 100/ hr hrs 1.58 D C EC-1006M-4 Black 100/12 2 hr hrs 1.62 A C > EC-1006M-5 Black 100/14 2 hr hrs 2.1 A C > EC-1009 Black 100/ hr hrs 1.9 D C C 24 hrs Black 100/ hr C+ 1.7 D C EH-20M C + 1 Black 100/10 >3 hr D C EH C EC-1012M-3 Blue 100/ hrs D C minutes C 105 C EC-1015 Black 100/25 >8 hr C 1.95 D C EC-1015LV Black 100/9 >4 hr C 2.1 D C EC-1015LV- 24 hrs Black 100/ hr D C RT 2 70 C 130 C EC-1015M-3 ONE C Black 1 Month 80, D C PART EC-1017 Black 100/6 >4 hr 45, C 2.36 D C EC-1017RT Black 100/6 1-2 hrs 30, hrs 2.36 D C EC-1207 Gray 100/100 2 hr hrs 1.55 D C > , C 105 C

4 EH-20M EH-26 HIGH TEMPERATURE - EPOXY COMPOUNDS Pot 25 C Mix Viscosity Black 100/ hr Black 100/10 >3 hr hrs C C + 1 Glass Transition Temp (Tg) CTE below Tg (in/in/10-6 ) 1.7 D C D C EC-1015 Black 100/25 >8 hr C 1.95 D C EC-1015LV Black 100/9 >4 hr C 2.1 D C EC-1015M-3 Black ONE PART 1 Month 80, C 2.25 D C EC-1017 Black 100/6 >4 hr 45, C 2.36 D C EC-1021 Black 100/25 >8 hrs C 1.72 D C EC Black 100/5 4 hrs C 1.9 D C EC-1026 Black 100/25 >8 hrs D EC-1027 Black 100/10 >4 hrs 39, C 1.76 D C EC-1052 Black 100/25 >8 hrs D EC-1052LV Black 100/10 >3 hrs C 1.7 D C EC-1082 Black 100/8 >4 hrs 70C C 1.82 D C Service Temp 190 C 155 C 220 C 190 C

5 SILICONE POTTING COMPOUNDS Pot life Mix Viscosity SC-440 Clear 100/100 2 hrs SC-450 Clear 100/10 1 hr hrs 1.05 A C to 200 C A C to 200 C SC-454M-6 Red 100/4 1 hr hrs 2.0 A C to 250 C SC-501 Gray 100/ hr SC-550 Gray 100/100 >48 hrs SC-550LV (UL Listed) SC-550LV-RT (UL Listed) Gray 100/100 >48 hrs Gray 100/ hrs C 2.0 A C to 200 C A C to 200 C A C to 200 C A C to 200 C 10 14

6 URETHANE POTTING COMPOUNDS Pot life Mix Viscosity UC-2521 Beige 25/ min UC-2524 Black 16/ min UC-2209 Blue 8/ min UC-2356 Black 45/ min UC-2658 Beige 44/ min UC Black 15/ min hrs hrs hrs hrs hrs hrs 1.4 D A A D A A

Features. Samples. Units Continous: Steady State Applied Voltage: DC Voltage Range (VM(DC)) 150 to 970 V AC Voltage Range (V M(AC)RMS

Features. Samples. Units Continous: Steady State Applied Voltage: DC Voltage Range (VM(DC)) 150 to 970 V AC Voltage Range (V M(AC)RMS S 34S Varistor Series RoHS Description The Littelfuse S 34S thermally protected varistor is a self-protected device. It consists of a 34mm square varistor with an integral thermal designed to open in the

More information

Capacitance range: mf to 25 mf Rated voltages: 250 VDC 400 VDC 630 VDC 1000 VDC 1600 VDC 2000 VDC 3000 VDC

Capacitance range: mf to 25 mf Rated voltages: 250 VDC 400 VDC 630 VDC 1000 VDC 1600 VDC 2000 VDC 3000 VDC WIMA Snubber MKP Snubber MKP Capacitors for Pulse Applications with ouble-sided Metallized Electrodes, Schoopage Contacts and Internal Series Connection Special Features Pulse duty construction Self-healing

More information

Solid-State Relays. Solid-State Relays. Features. Description. Overview

Solid-State Relays. Solid-State Relays. Features. Description. Overview Features Rugged, epoxy encapsulation construction 4,000 volts of optical isolation Subjected to full load test and six times the rated current surge before and after encapsulation Unique heat-spreader

More information

Solid-State Relays. Solid-State Relays. Features. Description. Overview

Solid-State Relays. Solid-State Relays. Features. Description. Overview Features Rugged, epoxy encapsulation construction 4,000 volts of optical isolation Subjected to full load test and six times the rated current surge before and after encapsulation Unique heat-spreader

More information

Wolf Kunststoff ZEDEX ZX-530 A5D Polymer Alloy

Wolf Kunststoff ZEDEX ZX-530 A5D Polymer Alloy Wolf Kunststoff ZEDEX ZX-530 A5D Polymer Alloy Category : Polymer, Thermoplastic Material Notes: Main Characteristics: Low Creep; Low moisture absorption; Flame retardant; Low impurity ions; Good machinability;

More information

VE09 M K. AC Operating Voltage (EIA coding) VE. Nominal Voltage at 1 ma dc (EIA coding) VF

VE09 M K. AC Operating Voltage (EIA coding) VE. Nominal Voltage at 1 ma dc (EIA coding) VF Ordering Code HOW TO ORDER VE09 M 0 0251 K Type VE 07 VE 09 VE 13 VE 17 VE 24 VF 05 VF 07 VF 10 VF 14 VF 20 VN 32 VB 32 Series M: Varistors for general applications P: Varistors for heavy duty applications

More information

3MPSERIES. Metallized Polypropylene. Dry Film Low Loss AC Filter Capacitor

3MPSERIES. Metallized Polypropylene. Dry Film Low Loss AC Filter Capacitor Film Capacitor Innovation Without Limits 3MPSERIES Metallized Polypropylene Dry Film Low Loss AC Filter Capacitor UL recognized component. Designed to handle high RMS currents for today s high energy AC

More information

Snubber, High Current DC, and Switching Capacitors

Snubber, High Current DC, and Switching Capacitors GTC 005 2011 Snubber, High Current DC, and Switching Capacitors Genteq Capacitors 1946 West Cook Road, Fort Wayne, Indiana 46818 USA Phone: (260) 416-5400 Fax: (260) 416-5460 Email: capacitors@regalbeloit.com

More information

CREATING TOMORROW S SOLUTIONS MOBILITY. e-novation FOR POWER CONVERSION POWERED BY SILICONES

CREATING TOMORROW S SOLUTIONS MOBILITY. e-novation FOR POWER CONVERSION POWERED BY SILICONES CREATING TOMORROW S SOLUTIONS MOBILITY e-novation FOR POWER CONVERSION POWERED BY SILICONES THE BRAIN OF e-mobility Highly-efficient power conversion is a vital process for e-mobility. The direct current

More information

GLASS TRANSITION TEMPERATURE (Tg) 65 C >2, , C >2, , C >2, , C 1, ,918 1.

GLASS TRANSITION TEMPERATURE (Tg) 65 C >2, , C >2, , C >2, , C 1, ,918 1. epotek.com Optical Epoxy Technology s extensive line of optical adhesives is used for bonding and coating in many applications; most commonly in fiberoptics. Our epoxy adhesives are frequently used to

More information

Advanced Materials. Raising insulation performance in car electronics

Advanced Materials. Raising insulation performance in car electronics Raising insulation performance in car electronics Quarter 2, 2013 Table of contents Raising performance Ignition coils Reliability and protection for electronic devices Improved endurance for ignition

More information

3 Pole, 27 Amp, Non-Reversing Across The Line Contactor With V Ac Coil and 1 No Auxiliary Contact

3 Pole, 27 Amp, Non-Reversing Across The Line Contactor With V Ac Coil and 1 No Auxiliary Contact 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 A12301084 Contact-600V 120VAC Coi Thomas & Betts Catalog Number Manufacturer Description Weight per unit Product Categy

More information

ATEX/IECEx Coil Manual Type 200 and 300 Series Coils for EH70 Series Solenoid Valves Issue , Released December 13, 2017

ATEX/IECEx Coil Manual Type 200 and 300 Series Coils for EH70 Series Solenoid Valves Issue , Released December 13, 2017 ATEX/IECEx Coil Manual Type 200 and 300 Series Coils for EH70 Series Solenoid Valves Issue 2017.1, Released December 13, 2017 Clark Cooper A Division of Magnatrol Valve Corp. 941 Hamilton avenue Roebling,

More information

GLASS TRANSITION TEMPERATURE (Tg) LAP SHEAR STRENGTH (PSI ) 65 C >2, , C >2, , C >2, ,946 1.

GLASS TRANSITION TEMPERATURE (Tg) LAP SHEAR STRENGTH (PSI ) 65 C >2, , C >2, , C >2, ,946 1. epotek.com Optical Epoxy Technology s extensive line of optical adhesives is used for bonding and coating in many applications; most commonly in fiberoptics. Our epoxy adhesives are frequently used to

More information

Andover Controls Duct and Immersion Temperature Sensors provide accurate measurement of air

Andover Controls Duct and Immersion Temperature Sensors provide accurate measurement of air Infinity Duct & Immersion Temperature Sensors Andover Controls Duct and Immersion Temperature Sensors provide accurate measurement of air temperature and fluid as part of an Andover Controls building automation

More information

How to Handle a Reed Switch

How to Handle a Reed Switch How to Handle a Reed Switch Reed Switch Application Notes APPLICATION NOTES: How to Handle a Reed Switch Reed switches consist of two or three metal reed contacts (blades) that are hermetically sealed

More information

Electro - Hydraulics. & Pneumatics. Electro Hydraulic Press. Comparison. Electro Hydraulics. By: Alireza Safikhani

Electro - Hydraulics. & Pneumatics. Electro Hydraulic Press. Comparison. Electro Hydraulics. By: Alireza Safikhani Electro - 9 Hydraulics & Pneumatics 2 Electro Hydraulic Press The hydraulic press is controlled via the electrical control panel. Electrical signals are used to activate the valves in the hydraulic installation.

More information

Cooling from Down Under Thermally Conductive Underfill

Cooling from Down Under Thermally Conductive Underfill Cooling from Down Under Thermally Conductive Underfill 7 th European Advanced Technology Workshop on Micropackaging and Thermal Management Paul W. Hough, Larry Wang 1, 2 February 2012 Presentation Outline

More information

BF Series Flasher Thermal flasher circuitry

BF Series Flasher Thermal flasher circuitry BF Series Flasher Thermal flasher circuitry Long life 2A load rating @ 115V AC Low cost Small size All units work on AC and DC input voltage 3 terminal configuration 6V to 115V input voltages available

More information

1.0 Rated Values and Operational Data

1.0 Rated Values and Operational Data Applications Protection and Commutation Power Electronics Impulsional devices with intensive / High Current Switching Power Supplies Main Characteristics Dry film-foil technology Nominal Voltage: 630 VDC

More information

Solid State Relays Datasheet WG 480 D...Z

Solid State Relays Datasheet WG 480 D...Z Datasheet WG 4 D...Z Features Switching Zero cross Output Input Back to back SCR with internal snubber DC with constant current control Applications Resistive and inductive loads with cos > 0.85 Technical

More information

Solid State Relays Datasheet WG 480 D...Z

Solid State Relays Datasheet WG 480 D...Z Datasheet WG 4 D...Z Features Switching Zero cross Output Input Back to back SCR with internal snubber DC with constant current control Applications Resistive and inductive loads with cos > 0.85 Technical

More information

Self Qualification Plan

Self Qualification Plan IMO Backend Innovation Divisional Philips Internal Report No.: QTS Report Database No.: 050266 Self Qualification Plan TSSOP56 packages using: - NiPdAu preplated frames - Hysol QMI-519 die-attach - Nitto

More information

Industrial Contactors CTX 3 3P 185A - 800A

Industrial Contactors CTX 3 3P 185A - 800A 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Industrial Contactors CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Installation - Connection...

More information

SPECIFICATIONS OXYMAX SUB-SURFACE AERATION SYSTEM

SPECIFICATIONS OXYMAX SUB-SURFACE AERATION SYSTEM SPECIFICATIONS OXYMAX SUB-SURFACE AERATION SYSTEM 1.0 GENERAL 1.1 DESCRIPTION A. Manufacturer shall furnish an aeration system capable of providing more equal distribution of oxygenated water throughout

More information

2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm

2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm 2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm Lockable manual override as standard For liquid, gaseous and aggressive media Long service life, even in non-lube conditions

More information

2/2- and 3/2-way solenoid valve for aggressive fluids

2/2- and 3/2-way solenoid valve for aggressive fluids 2/2- and 3/2-way solenoid valve for aggressive fluids Type 0121 can be combined with Direct-acting, media-separated valve with diameter of up to DN 8 Maintenance-free pivoted armature technology Vibration-proof,

More information

ICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices

ICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices ICT TRANSFORMERS Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices TA SERIES INDUSTRIAL CONTROL TRANSFORMER Industrial control transformers

More information

AC..CS SAFETY WIREWOUND RESISTOR

AC..CS SAFETY WIREWOUND RESISTOR AC..CS SAFETY WIREWOUND RESISTOR INTRODUCTION Purpose Overview of the AC03..CS and AC05..CS fusible wirewound safety resistors Objectives Present an overview of this product s special electrical parameters

More information

SPECIFICATIONS ULTIMAX SUB-SURFACE DIRECTIONAL AERATION SYSTEM

SPECIFICATIONS ULTIMAX SUB-SURFACE DIRECTIONAL AERATION SYSTEM SPECIFICATIONS ULTIMAX SUB-SURFACE DIRECTIONAL AERATION SYSTEM 1.0 GENERAL 1.1 DESCRIPTION A. Manufacturer shall furnish an aspirating directional aerator (aspirator) or a high-flow directional aerator

More information

Model Number Structure. Power Controllers G3PX. Single-phase Models. Model Number Legend

Model Number Structure. Power Controllers G3PX. Single-phase Models. Model Number Legend Power Controllers GPX Refer to Safety Precautions (page 0). Single-phase Models EUN Series AC Power Controllers with Phase-control System Allow Precise Temperature Control Models with Base-up and Soft-start

More information

SECTION B1: MACHINE COMPONENTS

SECTION B1: MACHINE COMPONENTS SECTION B1: MACHINE COMPONENTS The machine portion of the Injected Metal Assembly system provides the means for: holding, heating and injecting the alloy; distributing and controlling electrical, pneumatic,

More information

Solid State Relays Industrial, 1-Phase ZS (IO) w. LED and Built-in Varistor Types RM 23, RM 40, RM 48, RM 60

Solid State Relays Industrial, 1-Phase ZS (IO) w. LED and Built-in Varistor Types RM 23, RM 40, RM 48, RM 60 Solid State Relays Industrial, 1-Phase ZS (IO) w. LED and Built-in Varistor Types RM 23, RM 40, RM 48, RM 60 Zero switching (RM1A) or instant-on switching (RM1B) AC Solid State Relay Direct copper bonding

More information

Type FEC Epoxy Encapsulated, Copper-Wound Industrial Control Transformers

Type FEC Epoxy Encapsulated, Copper-Wound Industrial Control Transformers Type FEC Epoxy Encapsulated, Copper-Wound Transformers ISO 900:2008 REGISTERED 0 Transformer Selector Guide Type FEC Transformers...Page 02 Primary Fusing Option...Page 07 Primary Overcurrent Selection...Page

More information

SECTION B: SYSTEM OPERATING COMPONENTS

SECTION B: SYSTEM OPERATING COMPONENTS SECTION B: SYSTEM OPERATING COMPONENTS A brief description of the machine, Cable Processor Module and tooling will provide a better understanding of the various functions of the IMA system. SECTION B1:

More information

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER. Models

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER. Models SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED type Models Indoor unit ASH9LSACW ASH12LSACW Outdoor unit AOH9LSAC AOH12LSAC CONTENTS SPECIFICATIONS...................... 1 DIMENSIONS..........................

More information

Graco PD44. Patented Meter, Mix and Dispense Valve for Two-Component Micro Dispensing

Graco PD44. Patented Meter, Mix and Dispense Valve for Two-Component Micro Dispensing Graco PD44 Patented Meter, Mix and Dispense Valve for Two-Component Micro Dispensing Graco PD44 Valve for Precise Micro-Dispensing 1.0cc 0.50cc 0.25cc 0.1cc 0.005cc 1/16" Dia. 1/8" Dia. 3/16" Dia. 1/4"

More information

Audi A4 Current Flow Diagram No. 50 / 1 Edition

Audi A4 Current Flow Diagram No. 50 / 1 Edition Page 1 of 8 Audi A4 Current Flow Diagram No. 50 / 1 Edition 12.2003 5-speed automatic gearbox with Tiptronic From model year 2002 Main fuse On battery Fuse box Dash panel, driver's side Fuse colours 30

More information

Unit Cooler. Small to Medium Walk - Ins. Coolers & Freezer Applications

Unit Cooler. Small to Medium Walk - Ins. Coolers & Freezer Applications Now available with EC Motors High Efficiency / High Reliability Low rofile Unit Cooler ublication No. 100.15 November, 2008 Air Defrost - 3,900 to 39,000 BTUH Electric Defrost - 3,600 to 28,000 BTUH Hot

More information

SAFR LED SERIES S A F R L E D. Hazardous Location LED Luminaire

SAFR LED SERIES S A F R L E D. Hazardous Location LED Luminaire SAFR LED SERIES Hazardous Location LED Luminaire Class I, Division 2, Groups A, B, C & D Class II, Division & 2, Groups E, F & G Class III Class I, Zone 2, Groups IIA, IIB & IIC UL 8750 LED Safety UL 844

More information

Design Build Deliver. Metal Enclosed Switchgear, 5-35kV 1200 A Maximum Loadbreak, 4000 A Maximum Non-Loadbreak

Design Build Deliver. Metal Enclosed Switchgear, 5-35kV 1200 A Maximum Loadbreak, 4000 A Maximum Non-Loadbreak Metal Enclosed Switchgear, 5-35kV 1200 A Maximum Loadbreak, 4000 A Maximum Non-Loadbreak Powergrid Solution s Metal Enclosed Switchgear has many different customizable options and configurations. Customers

More information

Date:08/01/2001. Aluminum Electrolytic Capacitors Engineering Bulletin for SK Type Page: 1/7

Date:08/01/2001. Aluminum Electrolytic Capacitors Engineering Bulletin for SK Type Page: 1/7 YAGEO Corporation Date:08/01/2001 Aluminum Electrolytic Capacitors File:2052 Engineering Bulletin for SK Type Page: 1/7 SK Type +85ºC Single-ended lead aluminum electrolytic capacitors for the rated voltage

More information

PPT 802, Proximity Probe Transducer System

PPT 802, Proximity Probe Transducer System PPT 802, Proximity Probe Transducer System PPH 080 : Proximity Probe Head PEC 036 : Probe Extension Cable PRD 020 : Proximity Probe Driver Feature Non-contacting measurement system based on eddy current

More information

LOW HEIGHT UNIT COOLER

LOW HEIGHT UNIT COOLER Publication No. RU-CTA-0818A Replaces RU-CTA-0712A Ceiling-Temp LOW HEIGHT UNIT COOLER Small to Medium Walk-Ins Cooler and Freezer Applications Air Defrost,00 to 27,00 BTUH Electric Defrost 5,00 to 27,00

More information

Auxiliary contact blocks - with spring terminals Accessories

Auxiliary contact blocks - with spring terminals Accessories Auxiliary contact blocks - with spring terminals Accessories CA3-10S 1SBC101037F0014 Description The auxiliary contact blocks are used for the operation of auxiliary circuits and control circuits. CA3

More information

DV Tecnologia Company Group

DV Tecnologia Company Group TECHNICAL NOTES OF PPTC POLIMERIC THERMISTOR RESETABLE FUSE How does the Polymer-Resettable-Fuse effect work? A Polymer-Resettable-Fuse device comprises a polymer matrix that is loaded with carbon black

More information

Passat Current Flow Diagram No. 46 / 1 Edition

Passat Current Flow Diagram No. 46 / 1 Edition Page 1 of 5 Passat Current Flow Diagram No. 46 / 1 Edition 07.2008 Dual clutch gearbox 02E From May 2005 Notes: For information concerning Relay and fuse assignment Multi-pin connectors Control units and

More information

How Proper Application of Thermally Conductive Materials Will Improve Motor Power Density

How Proper Application of Thermally Conductive Materials Will Improve Motor Power Density WHITE PAPER How Proper Application of Thermally Conductive Materials Will Improve Motor Power Density Daniel Barber, Staff Scientist, Open Technology Innovation LORD Corporation How Proper Application

More information

Material Selection Guide

Material Selection Guide Material Selection Guide Markets Communications Computers Transportation Electronics Appliances Medical Devices Industrial Applications LCD Gaskets Battery Pressure Pads Speaker Gaskets Environmental Seals

More information

ULTEM* 1010 Resin. SABIC Innovative Plastics - Polyether Imide. Actions. General Information. Product Description

ULTEM* 1010 Resin. SABIC Innovative Plastics - Polyether Imide. Actions. General Information. Product Description ULTEM* 1010 Resin SABIC Innovative Plastics - Polyether Imide Actions General Information Product Description Transparent, enhanced flow Polyetherimide (Tg 217C). ECO Conforming, UL94 V0 and 5VA listing.

More information

Spare Parts List - DUO 500 & DUO 2

Spare Parts List - DUO 500 & DUO 2 Spare Parts List - DUO 00 & DUO 2 Issue Date 03//200 Part No. 930.000 Issue B MD - 200 Water Inlet -2 Water Drainage 3-4 Wash Pump -6 Bottom Washing / Rinsing System 7-8 Top Washing / Rinsing System DUO

More information

CALL FOR A QUOTE (877)

CALL FOR A QUOTE (877) LiFePO4 Energy Storage Systems Overview POWERSYNC Lithium Iron Phosphate (LiFePO4) Energy Storage Systems (ESS) are designed for residential, commercial, or industrial scale projects where long lasting,

More information

SECTION I: INDEX. Accumulator, injection B1-15 maintenance G1-26

SECTION I: INDEX. Accumulator, injection B1-15 maintenance G1-26 SECTION I: INDEX A Accumulator, injection B1-15 maintenance G1-26 Alignment, nozzle seat/nozzle tip E- 4 checking G1-33 correcting poor alignment G1-33 procedure, nozzle alignment G1-31 Alloy D-3 contamination

More information

DC-DC CONVERTERS 2:1 INPUT RANGE, UP TO 2 WATTS MEDICAL APPLICATIONS MTWA2 SERIES

DC-DC CONVERTERS 2:1 INPUT RANGE, UP TO 2 WATTS MEDICAL APPLICATIONS MTWA2 SERIES DC-DC CONVERTERS 2:1 INPUT RANGE, UP TO 2 WATTS MEDICAL APPLICATIONS FEATURES 2:1 Wide Input Voltage Range: 4.5-12 Input, 9-18 and 18-36 and 36-75 5000Vac Input to Output 2MOPP Isolation Remote On/Off

More information

Texin 245 Covestro PUR Thermoplastic Polyurethane Elastomer (Polyester) Action Saturday, October 22, 2016 Units English Legend (Open) General Information Product Description Texin 245 resin is an aromatic

More information

SECTION I: INDEX. Accumulator, injection B1-15 maintenance G1-12. Cable termination equipment A-3

SECTION I: INDEX. Accumulator, injection B1-15 maintenance G1-12. Cable termination equipment A-3 SECTION I: INDEX A Accumulator, injection B1-15 maintenance G1-12 Alignment, nozzle seat/nozzle tip E- 4 checking G1-18 correcting poor alignment G1-18 procedure, nozzle alignment G1-16 Alloy D-3 contamination

More information

100V 160V 200V 250V 400V

100V 160V 200V 250V 400V CL12 Polyester Film Capacitors Structures: Polypropylene film, non- inductive, phenolic resin coating Features: Excellent frequency and temperature characteristics, Very small loss even at high frequency.

More information

Innovative Solutions for Electric Motors

Innovative Solutions for Electric Motors Innovative Solutions for Electric Motors Innovative Solutions for Electric Motors Gasketing Retaining 1. 2. 3. Threadlocking 10. Coatings & Cleaners 4. Threadsealing 9. 5. Magnet 8. 6. Potting 7. General

More information

Product Specifications Sheets

Product Specifications Sheets Product Specifications Sheets 35 Series Service Case Double Duty - Deli Pass-Thru Model Power Est. Ship Model No. Description Length Depth Height Voltage Amps HP/BTUs Cord Weight SC-CDS35-4 Self-contained

More information

Thermoplastic Hose Quick Reference Guide

Thermoplastic Hose Quick Reference Guide Thermoplastic Hose Quick Reference Guide 4703 4700 SAE 100R3 SAE 100R7 Low Pressure Hydraulics High Pressure Pneumatics Hand Tools Lubrication System Pilot Lines and Joystick Controls General Hydraulics

More information

TABLE of contents. Metal Oxide Varistor (MOV) Varistors-5D Series Varistors-7D Series Varistors-10D Series... 5

TABLE of contents. Metal Oxide Varistor (MOV) Varistors-5D Series Varistors-7D Series Varistors-10D Series... 5 TABLE of contents Subject Page Metal Oxide Varistor (MOV)..................................................... 1 Varistors-5D Series............................................................ 3 Varistors-7D

More information

THIS PAGE WAS INTENTIONALLY LEFT BLANK.

THIS PAGE WAS INTENTIONALLY LEFT BLANK. THIS PAGE WAS INTENTIONALLY LEFT BLANK. Table of Contents Features... 2 Applications... 2 Approvals... 2 Part Marking... 3 System... 4 Absolute Ratings... 4 Fuse Configuration and Dimensions... 5 Specifications...

More information

SPECIFICATION. Provide a bridge or parking garage joint seal that consists of either: DISTRIBUTED BY: CANADIAN CONSTRUCTION PRODUCTS

SPECIFICATION. Provide a bridge or parking garage joint seal that consists of either: DISTRIBUTED BY: CANADIAN CONSTRUCTION PRODUCTS A. General The wk shall consist of furnishing and installing a high perfmance, closed cell, prefmed seal in accdance with the details shown on the plans and the requirements of the specifications. Manufacturer

More information

MIXVENT-TH Series Mixed Flow Fans

MIXVENT-TH Series Mixed Flow Fans ROOF MOUNTED FNS MIXVENT-TH Series Mixed Flow Fans 0 021682 603075 P P L I T I O N S Range of roof mounted mixed flow fans supplied as standard for extract operation. The models 500 and 800 are manufactured

More information

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1 Automation Datacom IPC Industry Measurement Telecom Automobile Boat Charger Medical PV Railway PART NUMBER STRUCTURE FDC10-48 S 05 W - M2 P HC Series Name Input Output Output Input Operating Temp. Remote

More information

6" SUBMERSIBLE MOTORS - DIMENSIONS AND WEIGHTS

6 SUBMERSIBLE MOTORS - DIMENSIONS AND WEIGHTS 6" SUBMERSIBLE MOTORS - DIMENSIONS AND WEIGHTS STANDARD HP / kw Construction L (in) Motor Carton Size (in) Shipping Wt. W H L lbs kg 5 / 3.7 304 SS 3-Lead 22.9 7.50 10.75 34.50 101 46 3-Lead 22.5 7.50

More information

3-Way Solenoid Valve - Direct Acting

3-Way Solenoid Valve - Direct Acting 3-Way Solenoid Valve - Direct Acting General application valves for dry or lubricated air, neutral gases and liquids Description: Applications: 3-Way Solenoid Valve - Direct Acting - Normally Closed. Coil

More information

44 SERIES. PCB/Plug-in relays from 6 to 10 A

44 SERIES. PCB/Plug-in relays from 6 to 10 A 44 PCB/Plug-in relays from 6 to 10 44 2 CO power relays with high separation between adjacent contacts Direct PCB or socket mount Type 44.52 -- 2 CO 6 (5 mm pin pitch) Type -- 2 CO 10 (5 mm pin pitch)

More information

HEAVY DUTY POWER RELAYS FEATURES

HEAVY DUTY POWER RELAYS FEATURES VDE VC HEAVY DUTY POWER RELAYS VC RELAYS Faston terminal Screw terminal mm 9 FEATURES VC power relays are designed for controlling heavy duty loads safely: Contact gap of 3 mm or more -point contacts for

More information

TAE pole Contactors

TAE pole Contactors TAE9...26 3-pole Contactors d.c. operated with double-winding coil SB8033C3 Utilisation TAE9 to TAE26 contactors are a compliment to the DC control contactor range. The coils have large voltage ranges

More information

1 Form A 5A small size power relay for interface

1 Form A 5A small size power relay for interface 1 Form A 5A small size power relay for interface PQ RELAYS RoHS compliant Protective construction: Sealed type FEATURES 1. Compact and slim 20 mm (L) mm (W) 16 mm (H).787 inch (L).394 inch (W).630 inch

More information

EMI Suppression Capacitors

EMI Suppression Capacitors Construction Plastic case (UL 94 V-0) Epoxy resin sealing, flame-retardant Axial leads, insulating sleeve (type B8119 Self-healing Smallest possible dimensions Terminals Parallel wire leads, tinned Two

More information

spare parts fast moving items genuine 4x300W LED

spare parts fast moving items genuine 4x300W LED s t s r m a e n e g e n fa i u e g n r i a v o p m s st p t i Mast & Floodlights spare parts LED Floodlight 300W AC000_E026_019 Floodlight top support LED04_C000_014ZN Floodlight lower support LED04_C000_011ZN

More information

NAVSEA REVIEWED ASTM F-718. If this product is to be applied as part of a coating system, all components of the system must be as listed on the QPL.

NAVSEA REVIEWED ASTM F-718. If this product is to be applied as part of a coating system, all components of the system must be as listed on the QPL. ASTM F-718 International Paint, LLC Intergard 403, Epoxy Anticorrrosive PRODUCT DESIGNATIONS Part A: KBA400 series Part B: KBA403 MIL-PRF-23236 If this product is to be applied as part of a coating system,

More information

P2 : About Us. P3 : Elsewedy Transformers. P4 : Why Elsewedy Dry Type Transformer? P6 : Cast Resin Dry Transformers. P7 : Technical Data Sheets

P2 : About Us. P3 : Elsewedy Transformers. P4 : Why Elsewedy Dry Type Transformer? P6 : Cast Resin Dry Transformers. P7 : Technical Data Sheets P2 : About Us P3 : Elsewedy Transformers P4 : Why Elsewedy Dry Type Transformer? P6 : Cast Resin Dry Transformers P7 : Technical Data Sheets P8 : Transformer s Outline Drawing P9 : Accessories About Us

More information

Power Controller. (see note 1) 10 sec

Power Controller. (see note 1) 10 sec Power Controller Single-phase Models EUN Series AC Power Controller with Phase-control System Allows Precise Temperature Control Models with Base-up and Soft-start Functions Available EH Series Phase Control

More information

Metallized Polypropylene Film Capacitor DC-Link capacitor

Metallized Polypropylene Film Capacitor DC-Link capacitor Metallized Polypropylene Film Capacitor DC-Link capacitor APPLICATIONS Industrial and high-end power supplies High performance DC filtering Frequency converters Solar inverters Renewable energies inverters

More information

Recommended Applications Interference suppressor for AC Primary Line of electronic equipments. Explanation of Part Numbers.

Recommended Applications Interference suppressor for AC Primary Line of electronic equipments. Explanation of Part Numbers. Type TS IEC60384-14 Sub-class Y2/X1 Type NS-A IEC384-14 Sub-class Y1/X1 Type BE 250 VAC For Japan Domestic Safety Ceramic Disc Capacitors (Safety Regulations) Features Related by IEC60384-14 2nd Ed. and

More information

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors 90 Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors Environment characteristics Conforming to standards IEC 60947, NF C 63-110, VDE 0660, BS 5424 Product certifications LCp

More information

YAGEO Corporation Date: 01/17/2007

YAGEO Corporation Date: 01/17/2007 YAGEO Corporation Date: 01/17/2007 Aluminum Electrolytic Capacitors File:2063 Engineering Bulletin for SC Type Page: 1/7 SC Type -40 to +105 C Very low impedance and ESR, miniature aluminum electrolytic

More information

AT30 SERIES BATTERY CHARGER

AT30 SERIES BATTERY CHARGER STANDARD FEATURES 5 YEAR WARRANTY 5 Year Product Warranty Universal main control board operates in any AT Series charger Alarm assembly with local LEDs and summary relay contact for AC Failure, DC Failure,

More information

SDS05-48 S 05 W H Series Name Input Output Output Input Isolation Voltage Quantity Voltage Range Option PART NUMBER STRUCTURE

SDS05-48 S 05 W H Series Name Input Output Output Input Isolation Voltage Quantity Voltage Range Option PART NUMBER STRUCTURE Automation Datacom IPC Industry Measurement Telecom Automobile Boat Charger Medical PV Railway PART NUMBER STRUCTURE SDS05-48 S 05 W H Series Name Input Output Output Input Isolation Voltage Quantity Voltage

More information

Date 1/31/ E. 45th Avenue Denver, CO

Date 1/31/ E. 45th Avenue Denver, CO SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL-ICE0250A1,A2,A3-T1,T2,T3-W1,W2,W3 MODEL-ICE0400A1,A2-T1,T2-W1,W2 MODEL-ICE0500A1,A2-T1,T2-W1,W2-R1,R2,R3 MODEL-ICE0606A1,A2-T1,T2-W1,W2-R1,R2,R3 Includes 50Hz.

More information

G4 LED HID Retrofit. Standards Manual

G4 LED HID Retrofit. Standards Manual G4 LED HID Retrofit Standards Manual G4 HID Retrofit Series MEGALUMEN 22, 27, 36, 45, 54, 80, 100, 120W Mills Lighting 4th Generation MegaLumen Lamp boasts 150 lumen per watt. Mills Lighting LED-HIDRL

More information

Explosion-proof Solenoids ATEX. II 2 G / II 2 D EEx dm IIC T4, T5, T6. Catalogue 8735/GB. Maximum photo

Explosion-proof Solenoids ATEX. II 2 G / II 2 D EEx dm IIC T4, T5, T6. Catalogue 8735/GB. Maximum photo Explosion-proof Solenoids II 2 G / II 2 D EEx dm IIC T4, T5, T6 Catalogue Maximum photo ATEX Explosionproof solenoids with flameproof enclosure/encapsulation "dm" According to ATEX directive 94/9/EC and

More information

1000 VDC 1250 VDC 125 VAC 250 VAC J K M 125 VAC, 250 VAC

1000 VDC 1250 VDC 125 VAC 250 VAC J K M 125 VAC, 250 VAC Metallized Polyester Film Capacitor Type: ECQE(F) Non-inductive construction using metallized Polyester film with flame retardant epoxy resin coating Features Self-healing property Excellent electrical

More information

AE 9... AE 40 Contactors NE... Contactor Relays

AE 9... AE 40 Contactors NE... Contactor Relays Technical data AE 9... AE 0 Contactors NE... Contactor Relays AE 9... AE 0 Contactors NE.. Contactor Relays Contents AE 9... AE 0 Contactors Description... 2 Ordering Details... 3 Technical Data... Terminal

More information

SOLENOID VALVES 1. GENERAL PURPOSE VALVES ACCESSORIES ORDER CODIFICATION : TEC22 DIRECT ACTING INDIRECT ACTING

SOLENOID VALVES 1. GENERAL PURPOSE VALVES ACCESSORIES ORDER CODIFICATION : TEC22 DIRECT ACTING INDIRECT ACTING S 1. GENERAL PURPOSE VALVES DIRECT ACTING ACCESSORIES CONNECTORS FOR COILS (Protection class IP65) by DIN 43650 ADJUSTABLE TIMER to preset DUTY CYCLE A "TEST" button is provided and 2 leds are used to

More information

VALVE PLUGS. More Variety, Less Effort. ÔÔDecentralized. ÔÔEfficient. ÔÔIP67 Protection

VALVE PLUGS. More Variety, Less Effort. ÔÔDecentralized. ÔÔEfficient. ÔÔIP67 Protection VLVE PLUGS More Variety, Less Effort ÔÔDecentralized ÔÔEfficient ÔÔIP67 Protection What makes a Murrelektronik Valve Plug a Murrelektronik Valve Plug... ONNETION EFFIENY hoice of color (yellow, gray, black)

More information

1 3RT1016-1A**1 1 3RT1017-1A** RT1025-1A** RT1025-3A** RT1034-1A** RT1034-3A**0 175.

1 3RT1016-1A**1 1 3RT1017-1A** RT1025-1A** RT1025-3A** RT1034-1A** RT1034-3A**0 175. SIRIUS 3RT0 3-Pole with AC Coil 3RT0* through 3RT04* 4-point AC coil can be wired on top, bottom, or diagonally. Direct mount 3RU or 3RB0 solid state overload relays to create starters. Snap-on auxiliary

More information

Dinosaur Flexible Wiring Duct

Dinosaur Flexible Wiring Duct Dinosaur Flexible Wiring Duct Dinosaur self-adhesive flexible duct is ideal for transporting wiring to cabinet doors from control panel interiors (for that part of the cable run that leans against the

More information

MOTOR TERMINAL CONNECTIONS

MOTOR TERMINAL CONNECTIONS MOTOR TERMINAL CONNECTIONS Motor Classification Most of the industrial machines in use today are driven by electric motors Motors are classified according to the type of power used (AC or DC) and the motors

More information

Description. Applications

Description. Applications 3.5x2.8mm SURFACE MOUNT LED LAMP Features Industry standard PLCC-2 package. High reliability LED package. Wide viewing angle. Single color. Suitable for all SMT assembly and solder process. Available on

More information

Information 3 Form A 4 Industrial Form Type B 12 Form B 16 Form C 18 Micro Type C 22

Information 3 Form A 4 Industrial Form Type B 12 Form B 16 Form C 18 Micro Type C 22 TABLE OF CONTENTS Connectors Information 3 Form A 4 Industrial Form Type B 12 Form B 16 Form C 18 Micro Type C 22 Function Fittings Information 26 Flow Controls 27 Pilot Operated Check Valves 28 Pressure

More information

B. Coefficient table for calculation of capacitance after rated voltage increase

B. Coefficient table for calculation of capacitance after rated voltage increase Contents I. High voltage power capacitors A. High voltage internally fused capacitor B. Coefficient table for calculation of capacitance after rated voltage increase C. The selection of series reactor

More information

SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL-ICE0250, ICE0400, ICE0500, ICE0606

SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL-ICE0250, ICE0400, ICE0500, ICE0606 MODEL-ICE0250, ICE0400, ICE0500, ICE0606 ICE SERIES CUBERS SERVICE PARTS MANUAL Includes 50Hz. Units Ice-O-Matic 11100 East 45th Ave Denver, Colorado 80239 Part Number 9081299-01 Date 6/13 Table Of Contents

More information

NAVSEA REVIEWED ASTM F-718. Part A: MS-200 / MS209R D. Gray / MS207R Green / MS205R Red / MS201R White / MS203R Yellow / MS218H Part B

NAVSEA REVIEWED ASTM F-718. Part A: MS-200 / MS209R D. Gray / MS207R Green / MS205R Red / MS201R White / MS203R Yellow / MS218H Part B ASTM F-718 ITW Engineered Polymers, American Safety Technologies (AST) MS-200 Acrylic Epoxy Color Topping PRODUCT DESIGNATIONS Part A: MS-200 / MS209R D. Gray / MS207R Green / MS205R Red / MS201R White

More information

MBR2040FCT THRU MBR20200FCT. List... Package outline... Features Mechanical data Maximum ratings Electrical characteristics...

MBR2040FCT THRU MBR20200FCT. List... Package outline... Features Mechanical data Maximum ratings Electrical characteristics... List List... Package outline... 1 2 Features... 2 Mechanical data... 2 Maximum ratings... 2 Electrical characteristics... 2 Rating and characteristic curves... 3 Pinning information... 4 Marking... 4 Tube

More information

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 CTX 3 Control relays Cat. N (s) : 4 168 00..04/06/09..14/16/19..24/26/29 CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3.

More information

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals NSL..S 4-pole / 8-pole Contactor Relays - Spring DC Operated Description - 1-stack contactor relays: 4-pole, - 2-stack contactor relays: 8-pole, - Mechanically linked contact elements available, - Low

More information