The committee proposes the attached Public Input for further review at Second Draft.

Size: px
Start display at page:

Download "The committee proposes the attached Public Input for further review at Second Draft."

Transcription

1 National Fire Protection Association Report of /5/2017 1:55 PM Committee Input No. 60-NFPA [ Global Input ] The committee proposes the attached Public Input for further review at Second Draft. Submitter Information Verification Submitter Full Name: Barry Chase Organization: [ Not Specified ] Street Address: City: State: Zip: Submittal Date: Wed Oct 05 14:02:56 EDT 2016 Committee Statement Committee Statement: The proposed concept requires further investigation and review. Response Message: The committee has established a task group to review it for Second Draft. Public Input No. 135-NFPA [New Section after ] Public Input No. 134-NFPA [New Section after ] Public Input No. 137-NFPA [Section No [Excluding any Sub-Sections]] Public Input No. 138-NFPA [New Section after ] Public Input No. 140-NFPA [Section No ] Public Input No. 139-NFPA [New Section after ] Public Input No. 142-NFPA [Section No ] Public Input No. 141-NFPA [New Section after ] Public Input No. 143-NFPA [Section No ]

2 National Fire Protection Association Report of /5/2017 1:55 PM Committee Input No. 95-NFPA [ New Section after ] Data Registers. Data registers shall be provided in the controller in accordance with Chapter 14. Submitter Information Verification Submitter Full Name: Barry Chase Organization: [ Not Specified ] Street Address: City: State: Zip: Submittal Date: Fri Oct 07 14:47:02 EDT 2016 Committee Statement Committee Statement: This proposed revision is being presented for public review and comment. It will be considered for inclusion again at the comment stage. Among all of the issues encompassed by this proposal, the committee is particularly seeking public sentiment on the concept of requiring a data connection at all fire pumps. The intent is to take advantage of the developments in connectivity, data collection, and data analysis for multiple purposes, including development of code requirements and fire pump reliability. See also: CI 96 - NEW 12.9 CI 97 - NEW Chapter 14 (Inserted at the end of Chapter 13) Response Message: CI 98 - Annex C

3 National Fire Protection Association Report of /5/2017 1:55 PM Committee Input No. 96-NFPA [ New Section after 12.8 ] 12.9 Data Registers. Data registers shall be provided in the controller in accordance with Chapter 14. Submitter Information Verification Submitter Full Name: Barry Chase Organization: [ Not Specified ] Street Address: City: State: Zip: Submittal Date: Fri Oct 07 14:55:18 EDT 2016 Committee Statement Committee Statement: This proposed revision is being presented for public review and comment. It will be considered for inclusion again at the comment stage. Among all of the issues encompassed by this proposal, the committee is particularly seeking public sentiment on the concept of requiring a data connection at all fire pumps. The intent is to take advantage of the developments in connectivity, data collection, and data analysis for multiple purposes, including development of code requirements and fire pump reliability. See also: CI 95 - NEW CI 97 - NEW Chapter 14 (Inserted at the end of Chapter 13) CI 98 - Annex C Response Message:

4 National Fire Protection Association Report of /5/2017 1:55 PM Committee Input No. 97-NFPA [ New Section after 13.3 ] Chapter 14 Network and Data Registers. [see attached file] Supplemental Information File Name Description 20_CI-97.docx Proposed NEW Chapter 14 Submitter Information Verification Submitter Full Name: Barry Chase Organization: [ Not Specified ] Street Address: City: State: Zip: Submittal Date: Fri Oct 07 14:57:15 EDT 2016 Committee Statement Committee Statement: This proposed revision is being presented for public review and comment. It will be considered for inclusion again at the comment stage. Among all of the issues encompassed by this proposal, the committee is particularly seeking public sentiment on the concept of requiring a data connection at all fire pumps. The intent is to take advantage of the developments in connectivity, data collection, and data analysis for multiple purposes, including development of code requirements and fire pump reliability. See also: CI 95 - NEW CI 96 - NEW 12.9 CI 98 - Annex C Response Message:

5 Chapter 14 Network and Data Registers 14.1 Scope Connectivity is for remote monitoring and data gathering. It does not replace any of the alarm and signaling requirements of this standard General Communication between the controller and external devices shall be limited to one way (read only) No remote operation nor remote changing of any controller settings shall not be permitted Fire pump controllers shall be provided with standardized data registers in accordance with this chapter Network Connection The pump room shall have a wired Ethernet port providing a secure TCP/IP connection into a virtual private network or a public network for monitoring pump room data A wireless connection that meets the security and performance required by the property owners and subscribers shall be permitted in lieu of a wired Ethernet port Data Registers Data registers shall be provided in the electric fire pump controllers in accordance with Table Data registers shall be provided in the diesel fire pump controllers in accordance with Table Data registers shall be provided in both electric and diesel fire pump controllers for jockey pump operation and status in accordance with Table Data registers shall be provided in both electric and diesel fire pump controllers for performance data in accordance with Table (a) and Table (b) The controller shall be arranged to record and store the performance data with a time stamp for a given flow point when so initiated by the operator The data in Table , Table , and Table shall be continuously monitored by the controller and time stamped and recorded in an event log using Modbus protocol in Table (a), (b), and (c). An event record shall be triggered on 1) events listed in Tables (d), (e), and (f) 2) voltage and currents exceeding Δ% change during pump run with Δ adjustable up to 5% 3) pressure every hour 4) pressure value exceeding Δ% change with Δ adjustable up to 5% An Ethernet serial communications network using a standard web-based, text file format (HTML) may be used in lieu of the Modbus protocol in Tables (a), (b), and (c). The data in the text files shall be delimited The configuration shown in figure shall be a permissible connectivity arrangement for a electric fire pump installation The configuration shown in figure shall be a permissible connectivity arrangement for a diesel fire pump installation NFPA 20 Connectivity Proposal -1- Revised 10/02/2016

6 2019 NFPA 20 Connectivity Proposal -2- Revised 10/02/2016

7 Normal Power Emergency Power Power Distribution Panel Room Temperature Modbus Wired Ethernet Port Subscribers -Property Owner *Ethernet -Building Mgt Jockey Controller Electric Controller Modbus Gateway -Controller Service -Pump Service -Sprinkler Companies Wireless -NFPA -FM Speed -Government System and Suction Pressures Flow Performance Data Storage Annex C Format: Text Pump Case Temperature Sensors may be routed directly to the Gateway as an alternative to the Electric Controller *May be used for Event Log transmission in lieu of Modbus Controller Data Storage Tables: , , , Format: Modbus NFPA Electric Pump Room Connectivity Figure Acceptable Electric Fire Pump Connectivity Arrangement 2019 NFPA 20 Connectivity Proposal -3- Revised 10/02/2016

8 Power Distribution Panel Single Phase Branch Circuit Room Temperature Modbus Jockey Controller Fuel Level * Engine Instrument Panel Diesel Engine Diesel Controller Modbus (Optional) System & Suction Pressures **Ethernet Modbus Flow Gateway Wired Ethernet Port Wireless Performance Data Storage Annex C Format: Text Subscribers -Property Owner -Building Mgt -Controller Service -Engine Service -Pump Service -Sprinkler Companies -NFPA -FM -Government *Must include engine speed **May be used for Event Log transmission in lieu of Modbus Sensors may be routed directly to the Gateway as an alternative to the Diesel Controller Pump Case Temperature NFPA Diesel Pump Room Connectivity Controller Data Storage Tables: , , , Format: Modbus Figure Acceptable Diesel Fire Pump Connectivity Arrangement 2019 NFPA 20 Connectivity Proposal -4- Revised 10/02/2016

9 Electric Fire Pump Controller Table Modbus Registers Note: All Boolean values are positive true logic (logic high) Register Bit Description Units Write Range Scaling and Notes Controller Identification Manufacturer Name RO ASCII Text 20 characters Basic Model RO ASCII Text 20 characters Controller Type RO ASCII Text 20 characters Serial Number RO ASCII Text 20 characters Time and Date Stamp Last Data Update Hr RO Last Data Update Min RO Last Data Update Sec RO Last Data Update Mo RO Last Data Update Day RO Last Data Update Year RO Dynamic Real-time Data AC Volts Lines 1-2 V RO *Raw AC Volts Lines 2-3 V RO *Raw 2019 NFPA 20 Connectivity Proposal -5- Revised 10/02/2016

10 42053 AC Volts Lines 3-1 V RO *Raw AC Amps Line 1 A RO *Raw AC Amps Line 2 A RO *Raw AC Amps Line 3 A RO *Raw Line Frequency Hz RO *Raw System Pressure PSI/Bars/kPA RO *Raw Suction Pressure PSI/Bars/kPA RO *Raw Register Bit Description Units Write Range Scaling and Notes Net Pressure = System-Suction PSI/Bars/kPA RO *Raw Flow GPM/LPM RO Motor Speed RPM RO VFD Motor Speed Hz RO *Raw System Pressure at Pump Shutdown PSI/Bars/kPA RO *Raw Water Temperature, Pump Casing F RO *Raw Pump Room Temperature F RO *Raw Storage Tank Level Gallons RO 0-10,000,0000 Controller Settings Pressure Start PSI/Bars/kPA RO Pressure Stop PSI/Bars/kPA RO NFPA 20 Connectivity Proposal -6- Revised 10/02/2016

11 42083 Manual Stop Only RO 0 = Automatic, 1 = Manual Stop Only Run Period Timer Sec RO Sequential Timer Sec RO Weekly Test Timer Day of Week RO 0-6 Day, Sunday = Pressure RO 0 = PSI, 1 = Bar, 2 = kpa Flow RO 0 = GPM, 1 = LPM Temperature Units RO 0 = F, 1 = C Alarms D0 Minimum Run Delay Timing RO Boolean D1 Accelerate Delay Timing RO Bool D2 High Zone Delay Timing RO Bool D3 Sequence Delay Timing RO Bool D4 Load Shed Active RO Bool D5 Low Discharge Pressure Alarm RO Bool D6 Low Suction Alarm RO Bool D7 Low Suction Shutdown Active RO Bool D8 System Over Pressure Alarm RO Bool D9 Restart Delay Timing RO Bool Register Bit Description Units Write Range Scaling and Notes D10 Weekly Test Demand Active RO Bool 2019 NFPA 20 Connectivity Proposal -7- Revised 10/02/2016

12 D11 Failure to Start Alarm RO Bool D12 Lockout Active RO Bool D13 VFD Ready RO Bool D14 VFD Forward Command Active RO Bool D15 VFD Reverse Command Active RO Bool D0 Pressure Start Demand RO Bool D1 Remote Start Demand RO Bool D2 Deluge Start Demand RO Bool D3 Weekly Test Start Demand RO Bool D4 Local Start PB Demand RO Bool D5 Manual Operator Start Demand RO Bool D6 Audible Alarm RO Bool D7 Weekly/Monthly Test Setup Error RO Bool D8 Minimum Run Timed Out RO Bool D9 Load Shed Delay Timing RO Bool D10 Reserved RO Bool D11 Reserved RO Bool D12 Pressure Transducer Fault RO Bool D13 Pressure Transducer Test OK RO Bool D14 VFD Failure RO Bool 2019 NFPA 20 Connectivity Proposal -8- Revised 10/02/2016

13 D15 Controller in bypass, soft start/vfd only RO Bool D0 Timed Trip Timing RO Bool D1 Motor Running RO Bool D2 Motor Overload Alarm RO Bool D3 Motor Single Phasing Alarm RO Bool D4 Phase Reversal Alarm RO Bool D5 AC Voltage Low Alarm RO Bool D6 Reserved RO Bool D7 Transfer Switch in Normal Position RO Bool Register Bit Description Units Write Range Scaling and Notes D8 Transfer Switch in Emergency Position RO Bool D9 AC Power Available RO Bool D10 Transfer Switch Normal Power Available RO Bool D11 Transfer Switch Emergency Power Available RO Bool D12 Emergency CB Open RO Bool D13 CB Tripped RO Bool D14 Generator Engine Start Signal RO Bool D15 Low Pump Room Temperature RO Bool D0 AC Line Under Voltage Alarm RO Bool 2019 NFPA 20 Connectivity Proposal -9- Revised 10/02/2016

14 D1 AC Line Over Voltage Alarm RO Bool D2 AC Line Over Frequency Alarm RO Bool D3 AC Line Under Frequency Alarm RO Bool D4 Unused RO Bool D5 Unused RO Bool D6 Unused RO Bool D7 Unused RO Bool D8 Unused RO Bool D9 Unused RO Bool D10 Unused RO Bool D11 Unused RO Bool D12 Unused RO Bool D13 Unused RO Bool D14 Unused RO Bool D15 Unused RO Bool Historical Data Reserved Reserved Reserved Reserved 2019 NFPA 20 Connectivity Proposal -10- Revised 10/02/2016

15 Register Bit Description Units Write Range Scaling and Notes Reserved Reserved Minimum AC Volts Idle Lines 1-2 A RO Minimum AC Volts Idle Lines 2-3 A RO Minimum AC Volts Idle Lines 3-1 A RO Maximum AC Volts Idle Lines 1-2 A RO Maximum AC Volts Idle Lines 2-3 A RO Maximum AC Volts Idle Lines 3-1 A RO Minimum AC Volts Starting Lines 1-2 V RO *Raw Minimum AC Volts Starting Lines 2-3 V RO *Raw Minimum AC Volts Starting Lines 3-1 V RO *Raw Minimum AC Volts Running Lines 1-2 V RO *Raw Minimum AC Volts Running Lines 2-3 V RO *Raw Minimum AC Volts Running Lines 3-1 V RO *Raw Maximum AC Volts Running Lines 1-2 V RO *Raw Maximum AC Volts Running Lines 2-3 V RO *Raw Maximum AC Volts Running Lines 3-1 V RO *Raw 2019 NFPA 20 Connectivity Proposal -11- Revised 10/02/2016

16 42151 Minimum Frequency HZ RO *Raw Maximum Frequency HZ RO *Raw Last Locked Rotor AC Amps Line 1 A RO Last Locked Rotor AC Amps Line 2 A RO Last Locked Rotor AC Amps Line 3 A RO Minimum System Discharge Pressure PSI/Bars/kPA RO *Raw Maximum System Discharge Pressure PSI/Bars/kPA RO *Raw Start Count RO Register Bit Description Units Write Range Scaling and Notes Calls to Start Count RO Total Run Time Hours Hr RO Total Run Time Minutes Min RO Total Run Time Seconds Sec RO Pump Last Run Time Minutes Min RO Pump Last Run Time Seconds Sec RO Total Controller Power On Time Hours Hr RO Total Controller Power On Time Minutes Min RO Total Controller Power On Time Seconds Sec RO NFPA 20 Connectivity Proposal -12- Revised 10/02/2016

17 42199 Hours since last run Hr RO Hours since last DVS test Hr RO Last Pump Start Hr Hr RO Last Pump Start Minute Min RO Last Pump Start Second Sec RO Last Pump Start Month Mo RO Last Pump Start Day Day RO Last Pump Start Year Year RO Last Phase Failure Hr Hr RO Last Phase Failure Minute Min RO Last Phase Failure Second Sec RO Last Phase Failure Month Mo RO Last Phase Failure Day Day RO Last Phase Failure Year Year RO Last Phase Reversal Hr Hr RO Last Phase Reversal Minute Min RO Last Phase Reversal Second Sec RO Last Phase Reversal Month Mo RO Last Phase Reversal Day Day RO NFPA 20 Connectivity Proposal -13- Revised 10/02/2016

18 Register Bit Description Units Write Range Scaling and Notes Last Phase Reversal Year Year RO Last Locked Rotor Trip Hr Hr RO Last Locked Rotor Trip Minute Min RO Last Locked Rotor Trip Second Sec RO Last Locked Rotor Trip Month Mo RO Last Locked Rotor Trip Day Day RO Last Locked Rotor Trip Year Year RO Optional User Configurable 50 registers Event Log Access, Electric 32 registers Jockey Pump 50 registers Event Log Access, Jockey Pump 32 registers Reserved 37 registers 2019 NFPA 20 Connectivity Proposal -14- Revised 10/02/2016

19 Diesel Fire Pump Controller Table Modbus Registers Note: All Boolean values are positive true logic (logic high) Register Bit Description Units Write Range Scaling and Notes Controller Identification Manufacturer Name RO ASCII Text 20 characters Basic Model RO ASCII Text 20 characters Controller Type RO ASCII Text 20 characters Serial Number RO ASCII Text 20 characters Time and Date Stamp Last Data Update Hr RO Last Data Update Min RO Last Data Update Sec RO Last Data Update Mo RO Last Data Update Day RO NFPA 20 Connectivity Proposal -15- Revised 10/02/2016

20 42046 Last Data Update Year RO Dynamic Real-time Data Battery #1 Volts V RO *Raw Battery #2 Volts V RO *Raw ger 1 AC Power Input V RO Battery #1 Amps A RO *Raw Battery #2 Amps A RO *Raw ger 2 AC Power Input A RO System Pressure PSI/Bars/kPA RO *Raw Suction Pressure PSI/Bars/kPA RO *Raw Net Pressure = System-Suction PSI/Bars/kPA RO *Raw Register Bit Description Units Write Range Scaling and Notes Flow GPM/LPM Engine Speed RPM System Pressure at Pump Shutdown PSI/Bars/kPA RO *Raw Water Temperature, Pump Casing F RO *Raw Pump Room Temperature F RO *Raw Storage Tank Level Gallons RO 0-10,000,0000 Controller Settings 2019 NFPA 20 Connectivity Proposal -16- Revised 10/02/2016

21 42081 Pressure Start PSI/Bars/kPA RO Pressure Stop PSI/Bars/kPA RO Manual Stop Only RO 0 = Automatic, 1 = Manual Stop Only Run Period Timer Sec RO Sequential Timer Sec RO Weekly Test Timer Day of Week RO 0-6 Day, Sunday = Pressure RO 0 = PSI, 1 = Bar, 2 = kpa Flow RO 0 = GPM, 1 = LPM Temperature Units RO 0 = F, 1 = C Alarms D0 Minimum Run Delay Timing RO Boolean D1 Power Fail Start Delay Timing RO Bool D2 High Zone Delay Timing RO Bool D3 Sequence Delay Timing RO Bool D4 Engine Running RO Bool D5 High Water Temp Alarm RO Bool D6 Low Suction Alarm RO Bool D7 Low Suction Shutdown Active RO Bool D8 System Over Pressure Alarm RO Bool D9 Overspeed Alarm RO Bool 2019 NFPA 20 Connectivity Proposal -17- Revised 10/02/2016

22 D10 Weekly Test Demand Active RO Bool D11 Failure to Start Alarm RO Bool Register Bit Description Units Write Range Scaling and Notes D12 Lockout Active RO Bool D13 Crank on Battery #1 RO Bool D14 Crank on Battery #2 RO Bool D15 Crank Resting RO Bool D0 Pressure Start Demand RO Bool D1 Remote Start Demand RO Bool D2 Deluge Start Demand RO Bool D3 Weekly Test Start Demand RO Bool D4 Start Contactor #1 Fail RO Bool D5 Start Contactor #2 Fail RO Bool D6 Audible Alarm RO Bool D7 Weekly/Monthly Test Setup Error RO Bool D8 Minimum Run Timed Out RO Bool D9 Pump Demand RO Bool D10 Control Switch in Auto RO Bool D11 Control Switch in Manual RO Bool D12 Pressure Transducer Fault RO Bool 2019 NFPA 20 Connectivity Proposal -18- Revised 10/02/2016

23 D13 Pressure Transducer Test OK RO Bool D14 AC Power Fail Start RO Bool D15 Low Discharge Pressure Alarm RO Bool D0 Battery #1 Failure Alarm RO Bool D1 Battery #2 Failure Alarm RO Bool D2 Pump Trouble Group Alarm RO Bool D3 System Trouble #1 Alarm RO Bool D4 AC Power Fail Alarm RO Bool D5 Battery #2 Over Voltage Alarm RO Bool D6 Battery #1 Over Voltage Alarm RO Bool D7 Term 301, ECMS RO Bool D8 Term 302, FIM RO Bool D9 Term 303, ECMW RO Bool Register Bit Description Units Write Range Scaling and Notes D10 Term 304, ECMF RO Bool D11 Term 310, RWHIT RO Bool D12 Term 311, CRWCLS RO Bool D13 Term 312, LET RO Bool D14 Low Oil Pressure Alarm RO Bool D15 Low Pump Room Temperature RO Bool 2019 NFPA 20 Connectivity Proposal -19- Revised 10/02/2016

24 42104 D0 Battery #1 in Equalize RO Bool D1 Battery #2 in Equalize RO Bool D2 Battery #1 OK RO Bool D3 Battery #2 OK RO Bool D4 ger #1 Fail Alarm RO Bool D5 ger #2 Fail Alarm RO Bool D6 System Trouble #2 Alarm RO Bool D7 Engine Coolant Temperature High RO Bool D8 High Reservoir Level RO Bool D9 Low Reservoir Level RO Bool D10 Fuel Tank Level Low RO Bool D11 Fuel Tank Spill RO Bool D12 High Fuel Tank RO Bool D13 Relief Valve Open RO Bool D14 Unused RO Bool D15 Low Pump Room Temperature RO Bool Historical Data Minimum Battery #1 Voltage RO *Raw Minimum Battery #2 Voltage RO *Raw Maximum Battery #1 Voltage RO *Raw 2019 NFPA 20 Connectivity Proposal -20- Revised 10/02/2016

25 42113 Maximum Battery #2 Voltage RO *Raw Minimum Battery #1 Amps RO *Raw Register Bit Description Units Write Range Scaling and Notes Minimum Battery #2 Amps RO *Raw Maximum Battery #1 Amps RO *Raw Maximum Battery #2 Amps RO *Raw Minimum System Discharge Pressure PSI/Bars/kPA RO *Raw Maximum System Discharge Pressure PSI/Bars/kPA RO *Raw Start Count RO Calls to Start Count RO Total Run Time Hours Hr RO Total Run Time Minutes Min RO Total Run Time Seconds Sec RO Pump Last Run Time Minutes Min RO Pump Last Run Time Seconds Sec RO Total Controller Power On Time Hours Hr RO Total Controller Power On Time Minutes Min RO Total Controller Power On Time Seconds Sec RO NFPA 20 Connectivity Proposal -21- Revised 10/02/2016

26 42199 Hours since last run Hr RO Hours since last DVS test Hr RO Last Engine Start Hr Hr RO Last Engine Start Minute Min RO Last Engine Start Second Sec RO Last Engine Start Month Mo RO Last Engine Start Day Day RO Last Engine Start Year Year RO Last Engine Overspeed Hr Hr RO Last Engine Overspeed Minute Min RO Last Engine Overspeed Second Sec RO Last Engine Overspeed Month Mo RO 1-12 Register Bit Description Units Write Range Scaling and Notes Last Engine Overspeed Day Day RO Last Engine Overspeed Year Year RO Last ger Failure Hr Hr RO Last ger Failure Minute Min RO Last ger Failure Second Sec RO Last ger Failure Month Mo RO NFPA 20 Connectivity Proposal -22- Revised 10/02/2016

27 42227 Last ger Failure Day Day RO Last ger Failure Year Year RO Last Battery Trouble Hr Hr RO Last Battery Trouble Minute Min RO Last Battery Trouble Second Sec RO Last Battery Trouble Month Mo RO Last Battery Trouble Day Day RO Last Battery Trouble Year Year RO Last Low Fuel Level Hr Hr RO Last Low Fuel Level Minute Min RO Last Low Fuel Level Second Sec RO Last Low Fuel Level Month Mo RO Last Low Fuel Level Day Day RO Last Low Fuel Level Year Year RO Last Engine High Temperature Hr Hr RO Last Engine High Temperature Minute Min RO Last Engine High Temperature Second Sec RO Last Engine High Temperature Month Mo RO Last Engine High Temperature Day Day RO NFPA 20 Connectivity Proposal -23- Revised 10/02/2016

28 42246 Last Engine High Temperature Year Year RO Last Engine Low Pressure Hr Hr RO 0-23 Register Bit Description Units Write Range Scaling and Notes Last Engine Low Pressure Minute Min RO Last Engine Low Pressure Second Sec RO Last Engine Low Pressure Month Mo RO Last Engine Low Pressure Day Day RO Last Engine Low Pressure Year Year RO Optional User Configurable 50 registers Event Log Access, Diesel 32 registers Jockey Pump 50 registers Event Log Access, Jockey Pump 32 registers Reserved 37 registers 2019 NFPA 20 Connectivity Proposal -24- Revised 10/02/2016

29 Jockey Pump Controller Table Modbus Registers Note: All Boolean values are positive true logic (logic high) Register Bit Description Units Write Range Scaling and Notes Jockey Pump System Discharge Pressure PSI/Bars/kPA RO *Raw Jockey Pump Running 1 = Pump Running Jockey Power Available 1 = Power Available Controller Settings Jockey Stop Pressure Setting PSI/Bars/kPA RO Jockey Start Pressure Setting PSI/Bars/kPA RO Jockey Pump Switch is in AUTO RO 1 = Switch in AUTO Jockey Pump Switch is in MANUAL RO 1 = Switch in MANUAL Jockey Pump Switch is in OFF RO 1 = Switch in OFF Pressure Units RO 0 = PSI, 1 = bar, 2 = kpa 2019 NFPA 20 Connectivity Proposal -25- Revised 10/02/2016

30 Alarms Jockey Pump Failed to Start RO 1 = Fail to Start Jockey Pump Common Trouble RO 1 = Common Trouble Historical Data Start Count RO Total Jockey Run Time - Hours Hr RO Total Jockey Run Time - Minutes Min RO Optional User Configurable 15 registers Event Log Access, Jockey Pump 32 registers Reserved 37 registers Performance Data Tables Modbus Registers NFPA 20 Connectivity Proposal -26- Revised 10/02/2016

31 Present Data Table Previous Data Table Acceptance Data Table Address Offset Data Description Flow Measured System Suction Sys-Suc Amps Amps Amps Volts Volts Volts Table Year Mo Day Hr Min Sec Point % Flow Pressure Pressure Pressure RPM L1 L2 L3 L1-L2 L2-L3 L3-L1 Units Unused Starting Address ` Note: The controller shall be arranged to record and store the data for a given flow point when so initiated by the operator. Performance Data Tables (a) Data Register Detail 2019 NFPA 20 Connectivity Proposal -27- Revised 10/02/2016

32 Offset Data Description Range Units Write Scale +0 Year YR RO +1 Mo 1-12 Mo RO +2 Day 1-31 Day RO +3 Hr 0-23 Hr RO +4 Min 0-59 Min RO +5 Sec 0-59 Sec RO +6 % Flow Point % RO +7 Measured Flow 0-50,000 GPM/LPM RO +8 Suction Pressure PSI/bar/kPA RO 0.1 Raw +9 Sys-Suc Pressure* PSI/bar/kPA RO 0.1 Raw +10 System Pressure PSI/bar/kPA RO 0.1 Raw +11 RPM RPM RO +12 Amps L A RO 0.1*Raw +13 Amps L A RO 0.1*Raw +14 Amps L A RO 0.1*Raw +15 Volts L1-L V RO 0.1*Raw +16 Volts L2-L V RO 0.1*Raw +17 Volts L3-L V RO 0.1*Raw 0 = PSI, 1 = bar, +18 Table Units 2 = kpa RO +19 Table Units 0 = GPM, 1 = LPM RO *Net Pressure calculation Event Log Data Access Table (a) Modbus Registers Electric Controller Note: All Boolean values are positive true logic (logic high) 2019 NFPA 20 Connectivity Proposal -28- Revised 10/02/2016

33 Register Description Units Write Range Scaling and Notes Configure event record order setting RO 0 = Newest record first, 1 = Oldest record first Rewind Event Log RO 1 = Rewind Date and Time Stamp (Unix Based) RO 8-byte binary number Event ID RO System Pressure PSI/Bars/kPA RO *Raw Suction Pressure AC Volts Lines 1-2 V RO *Raw AC Volts Lines 2-3 V RO *Raw AC Volts Lines 3-1 V RO *Raw AC Amps Line 1 A RO *Raw AC Amps Line 2 A RO *Raw AC Amps Line 3 A RO *Raw Line Frequency Hz RO *Raw Optional User Configurable 22 registers Example Log: :00:00.00 Pressure Log 104 psi, 479V, 482V, 480V, 124A, 120A, 129A, 60Hz, NFPA 20 Connectivity Proposal -29- Revised 10/02/2016

34 Event Log Data Access Table (b) Diesel Controller Modbus Registers Note: All Boolean values are positive true logic (logic high) Register Description Units Write Range Scaling and Notes Configure event record order setting RO 0 = Newest record first, 1 = Oldest record first Rewind Event Log RO 1 = Rewind Date and Time Stamp (Unix Based) RO 8-byte binary number Event ID RO System Pressure PSI/Bars/kP A RO *Raw Suction Pressure Optional User Configurable 22 registers Battery #1 Volts V RO *Raw Battery #2 Volts V RO *Raw ger 1 AC Power Input V RO Battery #1 Amps A RO *Raw Battery #2 Amps A RO *Raw ger 2 AC Power Input A RO NFPA 20 Connectivity Proposal -30- Revised 10/02/2016

35 Example Log: :00:00.00 Pressure Log 104 psi, 13.1V, 13.7V, 120V, 119V, 6.5A, 10.1A, Event Log Data Access Table (c) Modbus Registers Jockey Controller Note: All Boolean values are positive true logic (logic high) Register Description Units Write Range Scaling and Notes Configure event record order setting RO 0 = Newest record first, 1 = Oldest record first Rewind Event Log RO 1 = Rewind Date and Time Stamp (Unix Based) RO 8-byte binary number Event ID RO System Pressure PSI/Bars/kPA RO *Raw Optional User Configurable 22 registers Example Log: :00:00.00 Pressure Log 104 psi, 2019 NFPA 20 Connectivity Proposal -31- Revised 10/02/2016

36 Electric Event Messages Table (d) ID Event message ID Event message 1 Pump Running 39 No Control Voltage 2 Pump Stopped 40 Load Disconnect 3 Low Clock Battery 41 Load Reconnect 4 Fail to Start 42 Local Start Input 5 Fail to Start Noted 43 Local Start Clear 6 Call to Start 44 Remote Start Input 7 Locked Rotor Trip 45 Remote Start Clear 8 Rotor Trip Clear 46 Emergency Run On 9 Over Voltage 47 Emergency Run Off 10 Over Frequency 48 Emergency Switch On 11 Under Voltage 49 Emergency Switch Off 12 Under Frequency 50 Over temp Bypass 13 Voltage Imbalance 51 Over temp Normal 14 Phase Failure 52 Motor Start Checked 15 Phase Reversal 53 Pressure Fail 16 Current > 320% FLA 54 Pressure in range 17 Motor Overload 55 USB drive near full 18 Battery Normal 56 USB drive has space 19 Nominal Voltage 57 USB drive error 20 Nominal Voltage 58 USB drive OK 21 Voltage Balanced 59 Pressure Log 22 Nominal Frequency 60 Pressure Log Run 23 Nominal Frequency 61 Database Clear 24 Phase Nominal 62 System Reset 25 Phase Sequence 63 Disk Dump 26 Nominal Current 64 Disk Dump Clear 27 Motor Normal 65 Data Log Cleared 2019 NFPA 20 Connectivity Proposal -32- Revised 10/02/2016

37 28 Interlock On 66 Clock Set Entered 29 Interlock Off 67 Clock Set Complete 30 Deluge Open 68 Low Suction Pressure 31 Deluge Closed 69 Suction Pressure OK 32 Low Pressure 70 Reservoir Low 33 Normal Pressure 71 Reservoir OK 34 Manual Stop Button 72 Low Pump Room Temp 35 Manual Stop Released 73 Pump Room Temp. OK 36 Power Transferred 74 Pump Room Trouble 37 Power Re-transferred 75 Pump Room Normal 38 Control Voltage OK 76 Min Start Volts ID Event message ID Event message 77 Max Start Current 115 VFD Drive Diagnostics On 78 Zone Enabled 116 VFD Drive Diagnostics Off 79 Zone Disabled 117 Weekly Test Due 80 Zone Call To Start 118 Weekly Test Due Clear 81 Zone Start Done 119 Softstarter fault 82 Load Shed 120 Softstarter Ok 83 Load Restored 121 Log softstarter fault 84 Weekly Test Running 122 Log VFD failure 85 Weekly Test Done 123 VFD Ready 86 Parameters Reset 124 VFD Not Ready 87 Passwords Reset 125 Shunt trip normal 88 Service due line 1 message 126 Shunt trip emergency 89 Service Due Reset 127 Flow meter On 90 Target Alarm 128 Flow meter Off 91 Target Alarm Clear 129 Low Pressure Sensor 92 City Water Press LOW 130 Auto start Input 93 City Water Press OK 131 Auto start Input Off 2019 NFPA 20 Connectivity Proposal -33- Revised 10/02/2016

38 94 Low Suction Level 132 Pressure Delta 95 Suction Level OK 133 1CR 96 Automatic Start 134 2CR 97 Automatic Start Clear 135 USB Drive Found 98 Calibration Error 136 USB Drive Access 99 Cal. Error Cleared 137 USB Open 100 Test In Progress 138 USB Open Failed 101 Test Completed 139 USB Writing 102 Jockey Pump Running 140 USB closed 103 Jockey Pump Off 141 Test Button 104 Jockey Pump Trouble 142 Test Failed 105 Jockey Pump OK 143 Test Override 106 Emergency Stop 144 Auto Shutdown Disabled 107 Emergency Stop Released 145 Auto Shutdown Enabled 108 Factory Mode 146 Manual Start 109 VFD Bypass 147 Daylight Savings 110 VFD Active 148 Service due line 2 message 111 VFD Failure 149 Duty pump 112 VFD Failure Clear 150 Standby pump 113 System Overpressure 151 Unit available 114 System Pressure OK 152 Unit not available ID Event message ID Event message 153 Dump valve On 191 Reserved for NFPA Standard 154 Dump valve Off 192 Reserved for NFPA Standard 155 Shutdown activated 193 Reserved for NFPA Standard 156 Shutdown released 194 Reserved for NFPA Standard 157 User input On 195 Reserved for NFPA Standard 2019 NFPA 20 Connectivity Proposal -34- Revised 10/02/2016

39 158 User input Off 196 Reserved for NFPA Standard 159 New firmware load 197 Reserved for NFPA Standard 160 New firmware detected 198 Reserved for NFPA Standard 161 DSS COMM fault 199 Reserved for NFPA Standard 162 DSS COMM Ok 200 Reserved for NFPA Standard 163 VFD COMM fault 201 Reserved for NFPA Standard 164 VFD COMM OK 202 Reserved for NFPA Standard 165 Relief valve open electric 203 Reserved for NFPA Standard 166 Relief valve open OFF electric 204 Reserved for NFPA Standard 167 DSS UTS too slow 205 Reserved for NFPA Standard 168 DSS PARAM fault 206 Reserved for NFPA Standard 169 DSS PARAM Clear 207 Reserved for NFPA Standard 170 VFD PARAM fault 208 Reserved for NFPA Standard 171 VFD PARAM Clear 209 Reserved for NFPA Standard 172 Manual Test Input 210 Reserved for NFPA Standard 173 Manual Test Clear 211 Reserved for NFPA Standard 174 Service Due line Reserved for NFPA Standard 175 Service Due line Reserved for NFPA Standard 176 VFD Sleep (power off) 214 Reserved for NFPA Standard 177 VFD Wakeup (power on) 215 Reserved for NFPA Standard 178 Reserved for NFPA Standard 216 Reserved for NFPA Standard 179 Reserved for NFPA Standard 217 Reserved for NFPA Standard 180 Reserved for NFPA Standard 218 Reserved for NFPA Standard 181 Reserved for NFPA Standard 219 Reserved for NFPA Standard 182 Reserved for NFPA Standard 220 Reserved for Controller Mfg 183 Reserved for NFPA Standard 221 Reserved for Controller Mfg 184 Reserved for NFPA Standard 222 Reserved for Controller Mfg 185 Reserved for NFPA Standard 223 Reserved for Controller Mfg 186 Reserved for NFPA Standard 224 Reserved for Controller Mfg 2019 NFPA 20 Connectivity Proposal -35- Revised 10/02/2016

40 187 Reserved for NFPA Standard 225 Reserved for Controller Mfg 188 Reserved for NFPA Standard 226 Reserved for Controller Mfg 189 Reserved for NFPA Standard 227 Reserved for Controller Mfg 190 Reserved for NFPA Standard 228 Reserved for Controller Mfg ID Event message 229 Reserved for Controller Mfg 230 Reserved for Controller Mfg 231 Reserved for Controller Mfg 232 Reserved for Controller Mfg 233 Reserved for Controller Mfg 234 Reserved for Controller Mfg 235 Reserved for Controller Mfg 236 Reserved for Controller Mfg 237 Reserved for Controller Mfg 238 Reserved for Controller Mfg 239 Reserved for Controller Mfg 240 Reserved for Controller Mfg 241 Reserved for Controller Mfg 242 Reserved for Controller Mfg 243 Reserved for Controller Mfg 244 Reserved for Controller Mfg 245 Reserved for Controller Mfg 246 Reserved for Controller Mfg 247 Reserved for Controller Mfg 248 Reserved for Controller Mfg 249 Reserved for Controller Mfg 250 Reserved for Controller Mfg 2019 NFPA 20 Connectivity Proposal -36- Revised 10/02/2016

41 Diesel Event Messages Table (e) ID Event message ID Event message 1 Engine Running 39 Database Clear 2 Engine Stopped 40 System Reset 3 Low Clock Battery 41 Disk Dump 4 Fail to Start 42 Disk Dump Clear 5 Fail to Start Noted 43 Data Log Cleared 6 Call to Start 44 Clock Set Entered 7 Over Voltage 45 Clock Set Complete 8 Under Voltage 46 Low Suction Pressure 9 Battery Normal 47 Suction Pressure Clear 10 Nominal Voltage 48 Pump Room Trouble 11 Nominal Voltage 49 Pump Room Normal 12 Interlock On 50 Zone Enabled 13 Interlock Off 51 Zone Disabled 14 Deluge Open 52 Zone Call To Star 15 Deluge Closed 53 Zone Start Done 16 Low Pressure 54 Weekly Test Running 2019 NFPA 20 Connectivity Proposal -37- Revised 10/02/2016

42 17 Normal Pressure 55 Weekly Test Done 18 Manual Stop Button 56 Parameters Reset 19 Manual Stop Released 57 Passwords Reset 20 Local Start On 58 Service due line 1 message 21 Local Start Clear 59 Service Due Reset 22 Remote Start Run 60 Flow Meter On 23 Remote Start Term 61 Flow Meter Clear 24 Emergency Run On 62 Fuel Spill Input 25 Emergency Run Clear 63 Fuel Spill Clear 26 Secondary ECM On 64 Engine Over speed 27 Secondary ECM Clear 65 Engine Over speed Clear 28 Emergency Switch On 66 Engine Temp High 29 Emergency Switch Off 67 Engine Temp High OK 30 Motor Start Checked 68 Oil Pressure Low 31 Pressure Fail 69 Oil Pressure Low OK 32 Pressure in range 70 Fuel Level Low 33 USB drive near full 71 Fuel Level Low OK 34 USB drive has space 72 Fuel Level High 35 USB drive error 73 Fuel Level High OK 36 USB drive OK 74 Low Pump Room Temp 37 Pressure Log 75 Pump Room Temp. OK 38 Pressure Log Run 76 Reservoir High ID Event message ID Event message 77 Reservoir High Clear 115 Jockey Pump Running 78 Reservoir Low 116 Jockey Pump Off 79 Reservoir Low Clear 117 Jockey Pump Trouble 80 Relief Valve Open 118 Jockey Pump OK 81 Relief Valve Closed 119 Battery 1 Out 82 ger 1 Fail 120 Battery 1 Out Off 2019 NFPA 20 Connectivity Proposal -38- Revised 10/02/2016

43 83 ger 1 Recovered 121 Battery 2 Out 84 ger 2 Fail 122 Battery 2 Out Off 85 ger 2 Recovered 123 ger 1 Out 86 Battery 1 Trouble 124 ger 1 Out Off 87 Battery 1 Clear 125 ger 2 Out 88 Battery 2 Trouble 126 ger 2 Out Off 89 Battery 2 Clear 127 Weekly Test Due 90 Crank 1 Button 128 Weekly Test Due Clear 91 Crank 1 Button Clear 129 System Overpressure 92 Crank 2 Button 130 System Pressure OK 93 Crank 2 Button Clear 131 Fuel Injector Fail 94 Calibration Error 132 Fuel Injector OK 95 Cal. Error Cleared 133 Primary Fail Start 96 No Control Voltage 134 Primary Fail Clear 97 Control Voltage OK 135 Primary Interrupt 98 Missing Battery 136 Primary Int. Cleared 99 Missing Battery OK 137 Coil continuity 1 Fail 100 AC Power Lost 138 Coil continuity 2 Fail 101 AC Power Restored 139 AC Power Loss Start 102 Test In Progress 140 AC voltage high 103 Test Completed 141 AC voltage normal 104 Automatic Start 142 AC voltage low 105 Automatic Start Clr 143 Secondary Crank 106 City Water Press LOW 144 Secondary Crank Off 107 City Water Press OK 145 AC Power Loss Delay 108 Low Suction Level 146 Fuel Valve Relay Status 109 Suction Level OK 147 Low Pressure Sensor 110 Target Alarm 148 Auto start Input 111 Target Alarm Clear 149 Auto start Input Off 2019 NFPA 20 Connectivity Proposal -39- Revised 10/02/2016

44 112 Main Switch Off 150 Pressure Delta 113 Main Switch Auto 151 Cranking Main Switch Manual 152 Cranking 2 ID Event message ID Event message 153 USB Drive Found 191 Term 303, ECMW 154 USB Access 192 Term 304, ECMF 155 USB Open 193 Term 310, RWHIT 156 USB Open Failed 194 Term 311, CRWCLS 157 USB Writing 195 Term 312, LET 158 USB closed 196 Reserved for NFPA Standard 159 Mode Off OFF 197 Reserved for NFPA Standard 160 Mode Auto OFF 198 Reserved for NFPA Standard 161 Mode Manual OFF 199 Reserved for NFPA Standard 162 Test Button 200 Reserved for NFPA Standard 163 Test Failed 201 Reserved for NFPA Standard 164 Test Override 202 Reserved for NFPA Standard 165 Auto Shutdown Disabled 203 Reserved for NFPA Standard 166 Auto Shutdown Enabled 204 Reserved for NFPA Standard 167 Manual Start 205 Reserved for NFPA Standard 168 Daylight Savings 206 Reserved for NFPA Standard 169 Service due line 2 message 207 Reserved for NFPA Standard 170 Duty pump 208 Reserved for NFPA Standard 171 Standby pump 209 Reserved for NFPA Standard 172 Unit available 210 Reserved for NFPA Standard 173 Unit not available 211 Reserved for NFPA Standard 174 Dump valve On 212 Reserved for NFPA Standard 175 Dump valve Off 213 Reserved for NFPA Standard 176 Shutdown activated 214 Reserved for NFPA Standard 2019 NFPA 20 Connectivity Proposal -40- Revised 10/02/2016

45 177 Shutdown released 215 Reserved for NFPA Standard 178 User input On 216 Reserved for NFPA Standard 179 User input Off 217 Reserved for NFPA Standard 180 New firmware load 218 Reserved for NFPA Standard 181 New firmware detected 219 Reserved for NFPA Standard 182 Manual Test Input 220 Reserved for Controller Mfg 183 Manual Test Clear 221 Reserved for Controller Mfg 184 Tank 1 Fail Input 222 Reserved for Controller Mfg 185 Tank 1 Fail Clear 223 Reserved for Controller Mfg 186 Tank 2 Fail Input 224 Reserved for Controller Mfg 187 Tank 3 Fail Clear 225 Reserved for Controller Mfg 188 Service Due line Reserved for Controller Mfg 189 Service Due line Reserved for Controller Mfg 190 Term 302, FIM 228 Reserved for Controller Mfg ID Event message 229 Reserved for Controller Mfg 230 Reserved for Controller Mfg 231 Reserved for Controller Mfg 232 Reserved for Controller Mfg 233 Reserved for Controller Mfg 234 Reserved for Controller Mfg 235 Reserved for Controller Mfg 236 Reserved for Controller Mfg 237 Reserved for Controller Mfg 238 Reserved for Controller Mfg 239 Reserved for Controller Mfg 240 Reserved for Controller Mfg 241 Reserved for Controller Mfg 2019 NFPA 20 Connectivity Proposal -41- Revised 10/02/2016

46 242 Reserved for Controller Mfg 243 Reserved for Controller Mfg 244 Reserved for Controller Mfg 245 Reserved for Controller Mfg 246 Reserved for Controller Mfg 247 Reserved for Controller Mfg 248 Reserved for Controller Mfg 249 Reserved for Controller Mfg 250 Reserved for Controller Mfg Jockey Event Messages Table (f) ID Event message ID Event message 1 Pump Running 39 Service due line 2 message 2 Pump Stopped 40 Mode Off Off 3 Low Clock Battery 41 Mode Auto OFF 4 Fail to Start 42 Mode Manual OFF 5 Fail to Start Noted 43 New firmware load 6 Call to Start 44 New firmware detected 2019 NFPA 20 Connectivity Proposal -42- Revised 10/02/2016

47 7 Phase Failure 45 Service Due line 3 8 Phase Reversal 46 Service Due line 4 9 Motor Overload 47 Reserved for NFPA Standard 10 Motor Normal 48 Reserved for NFPA Standard 11 Interlock On 49 Reserved for NFPA Standard 12 Interlock Off 50 Reserved for NFPA Standard 13 Low Pressure 51 Reserved for NFPA Standard 14 Normal Pressure 52 Reserved for NFPA Standard 15 Pressure Fail 53 Reserved for NFPA Standard 16 Pressure in range 54 Reserved for NFPA Standard 17 Pressure Log 55 Reserved for NFPA Standard 18 Pressure Log Run 56 Reserved for NFPA Standard 19 Database Clear 57 Reserved for NFPA Standard 20 System Reset 58 Reserved for NFPA Standard 21 Data Log Cleared 59 Reserved for NFPA Standard 22 Clock Set Entered 60 Reserved for NFPA Standard 23 Clock Set Complete 61 Reserved for NFPA Standard 24 Parameters Reset 62 Reserved for NFPA Standard 25 Passwords Reset 63 Reserved for NFPA Standard 26 Service due line 1 message 64 Reserved for NFPA Standard 27 Service Due Reset 65 Reserved for NFPA Standard 28 Automatic Start 66 Reserved for NFPA Standard 29 Automatic Start Clear 67 Reserved for NFPA Standard 30 Main Switch Off 68 Reserved for NFPA Standard 31 Main Switch Auto 69 Reserved for NFPA Standard 32 Main Switch Manual 70 Reserved for Controller Mfg 33 System Overpressure 71 Reserved for Controller Mfg 34 System Pressure OK 72 Reserved for Controller Mfg 35 Auto start Input Off 73 Reserved for Controller Mfg 2019 NFPA 20 Connectivity Proposal -43- Revised 10/02/2016

48 36 Pressure Delta 74 Reserved for Controller Mfg 37 1CR 75 Reserved for Controller Mfg 38 Daylight Savings 76 Reserved for Controller Mfg ID Event message 77 Reserved for Controller Mfg 78 Reserved for Controller Mfg 79 Reserved for Controller Mfg 80 Reserved for Controller Mfg 81 Reserved for Controller Mfg 82 Reserved for Controller Mfg 83 Reserved for Controller Mfg 84 Reserved for Controller Mfg 85 Reserved for Controller Mfg 86 Reserved for Controller Mfg 87 Reserved for Controller Mfg 88 Reserved for Controller Mfg 89 Reserved for Controller Mfg 90 Reserved for Controller Mfg 91 Reserved for Controller Mfg 92 Reserved for Controller Mfg 93 Reserved for Controller Mfg 94 Reserved for Controller Mfg 95 Reserved for Controller Mfg 96 Reserved for Controller Mfg 97 Reserved for Controller Mfg 98 Reserved for Controller Mfg 99 Reserved for Controller Mfg 100 Reserved for Controller Mfg 2019 NFPA 20 Connectivity Proposal -44- Revised 10/02/2016

49 2019 NFPA 20 Connectivity Proposal -45- Revised 10/02/2016

50 National Fire Protection Association Report of /5/2017 1:55 PM Committee Input No. 98-NFPA [ Chapter C ] [SEE ATTACHMENT FOR PROPOSED REVISIONS] Annex C Fire Pump Controller Connectivity This annex is not a part of the requirements of this NFPA document but is included for informational purposes only. C.1 Scope. C.1.1 This annex covers considerations relating to the access of fire pump controllers, including access methods, security considerations, accessible information, potential use of accessible information, long-term improvement in reliability, and standardization that allows the full potential of connectivity to be met. C.1.2 Potential use of accessible information includes remote supervision, remote monitoring that could include specific components for failure forecasting/component replacement, reliability analysis for owner, manufacturer, and NFPA or similar group for obtaining information only. No remote operation nor remote changing of any controller settings are to be permitted. C.1.3 Connectivity is for remote monitoring and data gathering. It does not replace any of the alarm and signaling requirements of this standard. C.1.4 The access can be local, such as a port (USB, RS-232, RS-485), or by remote access over any communication channel, such as phone line, Ethernet, Internet, Local Network (LAN), or other. C.1.5 This annex includes the following: (1) Possible controller access configurations (C.3) (2) Security considerations (C.4) (3) Some protection methods (C.5) (4) Standardization issues (C.6) Standardization means standardization per se that is, defining common data formats, and so forth, to allow access to a defined common set of data in any compliant controller. Controllers might also have proprietary data beyond the defined common set. C.1.6 Remote or local access to fire pump controller stored data has been in existence for over 20 years; however, each manufacturer has used proprietary means for accessing (reading or downloading or transferring) this data. There is a perceived need to extend these means to fire pump controllers in general, using some amount of commonality. C.1.7 Although none of the clauses in Annex C are enforceable, the intention for future editions of this standard is to incorporate requirements into the main body of this standard. It is likely that the more technical aspects will remain in the annex or be deleted in the future. C.2 General Definitions. C.2.1 Access. The ability to interrogate a controller in order to be able to read or download data. This can also include means of sending data or commands to a controller. Annex C addresses both local access and remote access.

51 National Fire Protection Association Report of /5/2017 1:55 PM C.2.2 Circuitry. Electrical/electronic circuitry which include microcontrollers and associated firmware. C.2.3 Cloud. The system of internet-connected devices and services. C.2.4 Connectivity. The issues involved with communicating with (connecting to) fire pump controllers. C.2.5 Encode. Encrypt. This can be used to hide data, passwords, access information, and so forth. C.2.6 Ethernet. High-speed serial connection. Each Ethernet device has (should have) a unique Ethernet MAC (media access control) address. These are 48 bit (12 hexadecimal digit) addresses such as: 00:A0:C9:14:C8:29. C.2.7 Firmware. A permanently stored processor program code (software); also called embedded program code. C.2.8 Global System for Mobile Communication (GMS). Cell phone technology. C.2.9 Internet. The global system of devices with routable IP addresses. C.2.10 IP. Internet protocol. C.2.11 IP-4 (IPV4). Internet version 4. Most of the extant internet is IP-4. LAN addresses are specific to IP-4. IP-4 uses 32-bit addresses (4 8) and has around 4.3 billion addresses. C.2.12 IP-6 (IPV6). The latest (next) internet version. Most of the current internet is IP-V. All IP-6 addresses are routable. IP-6 uses 128-bit addresses and provides many times more addresses than IP-4. C.2.13 IT Department. The company s information technology (computer) department. C.2.14 Local Area Network (LAN). A computer network that consists of either routable or non-routable IP addresses. C.2.15 Nonroutable. An IP address reserved for LAN use. These are not visible outside the local network. Typical LAN addresses are: 10.x.y.z, 19D x.y, and 17D.2.16/3D.2.x.y. C.2.16 Private Area Network (PAN). Short-range wireless networks such as: Bluetooth, ZigBee, infrared, and RFID. C.2.17 Routable. An IP address that is part of a routing table in a network (internet) router (or switch). These are visible to the outside world. C.2.18 Routing. The process of translating a device s IP address (usually a LAN address) into another IP address (usually a WAN or a routable address). C.2.19 RS-232 (EIA-32). A serial transmission electrical specification for two pieces of equipment.

DIESEL Engine Fire Pump Controllers Features

DIESEL Engine Fire Pump Controllers Features 1-1 Printer / Recorder The industrial grade thermal printer is housed in a rugged steel enclosure within the controller. The on/off switch, feed and reset buttons are front accessible. A bi-color status

More information

Technical Bulletin. Modbus TCP/IP Communication Protocol For Diesel Fire Pump Controllers

Technical Bulletin. Modbus TCP/IP Communication Protocol For Diesel Fire Pump Controllers Technical Bulletin Modbus TCP/IP Communication Protocol For Diesel Fire Pump Controllers General Characteristics Connection Type Shielded Female connector RJ45 Frame Format TCP/IP Default IP xxx.xxx.xxx.xxx

More information

Automatic Genset Controller, AGC-4 Display readings Push-button functions Alarm handling Log list

Automatic Genset Controller, AGC-4 Display readings Push-button functions Alarm handling Log list OPERATOR'S MANUAL Automatic Genset Controller, AGC-4 Display readings Push-button functions handling Log list DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614 Fax: +45 9614 9615 info@deif.com

More information

Caterpillar Electronic Technician 2012A v1.0 Product Status Report 9/23/2013 2:35 PM

Caterpillar Electronic Technician 2012A v1.0 Product Status Report 9/23/2013 2:35 PM Page 1 of 7 Caterpillar Electronic Technician 2012A v1.0 Product Status Report 2:35 PM Product Status Report Parameter Value Equipment ID 740 Comments C15 740 (LHX10244) Parameter Value Equipment ID 740

More information

MANUAL FOR MODEL FD4 FIRE PUMP CONTROLLERS

MANUAL FOR MODEL FD4 FIRE PUMP CONTROLLERS MANUAL FOR MODEL FD4 FIRE PUMP CONTROLLERS This manual provides General Information, Installation, Operation, Maintenance and System Set-Up Information for METRON Model FD-4 Engine Driven Fire Pump Controllers.

More information

OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets

OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets Art. nr. 40200261 OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets WHISPERPOWER BV Kelvinlaan 82 9207 JB Drachten Netherlands Tel.: +31-512-571550 Fax.: +31-512-571599

More information

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM DSE 520 ISSUE 4 4/4/02 MR 1 TABLE OF CONTENTS Section Page INTRODUCTION... 4 CLARIFICATION OF NOTATION USED WITHIN THIS PUBLICATION.... 4 1. OPERATION...

More information

SNMP dedicated to ORVALDI Solar Infini

SNMP dedicated to ORVALDI Solar Infini SNMP dedicated to ORVALDI Solar Infini User s Manual Management Software for Solar Inverter Table of Contents 1. 2. 3. Overview...1 1.1 Introduction...1 1.2 Features...1 1.3 Overlook...1 1.4 Installation

More information

PQube 3 Modbus Interface

PQube 3 Modbus Interface PQube 3 Modbus Interface Reference manual Revision 1.9 Modbus Interface Reference Manual 1.9- Page 1 Table of Contents 1. Background... 3 2. Basics... 3 2.1 Registers and Coils... 3 2.2 Address Space...

More information

CURTIS TOLEDO. AF Series Compressors VS models with VFD WARNING

CURTIS TOLEDO. AF Series Compressors VS models with VFD WARNING AUGUST, 2004 REV.A CURTIS TOLEDO OPERATOR S MANUAL SUPPLEMENT AF Series Compressors VS models with VFD WARNING Personal injury and/or equipment damage will result by failing to pay attention to the vital

More information

ICON 2 1. FEATURES AND CHARACTEIRICS

ICON 2 1. FEATURES AND CHARACTEIRICS ICON 2 1. FEATURES AND CHARACTEIRICS High end Micro-controller(DSP) technology Wide range of auxiliary supply: 7V to 45Vdc. Low power Consumption : 200 ma @ 12 V DC. Alphanumeric 16X4 or 16X2 LCD display

More information

HGM6410/6420 AUTOMATIC GENERATOR MODULE WITH J1939 INTERFACE SOFTWARE MANUAL

HGM6410/6420 AUTOMATIC GENERATOR MODULE WITH J1939 INTERFACE SOFTWARE MANUAL HGM6410/6420 AUTOMATIC GENERATOR MODULE WITH J1939 INTERFACE SOFTWARE MANUAL SMARTGEN ELECTRONICS Smartgen Electronic Equipment Co., Ltd No.12 Dongqing Street Zhengzhou Henan Province P.R.China Tel : (0086)-371-67992951

More information

Caterpillar Electronic Technician 2012C v1.0 Product Status Report 11/23/2013 2:25 PM

Caterpillar Electronic Technician 2012C v1.0 Product Status Report 11/23/2013 2:25 PM Page 1 of 13 Caterpillar Electronic Technician 2012C v1.0 Product Status Report 2:25 PM Product Status Report Product ID Comments Implement Control #2 Product ID ECM Part Number 3045687-01 19086375MS ECM

More information

Caterpillar Electronic Technician 2012A v1.0 Product Status Report 9/23/ :33 AM

Caterpillar Electronic Technician 2012A v1.0 Product Status Report 9/23/ :33 AM Page 1 of 7 Caterpillar Electronic Technician 2012A v1.0 Product Status Report 10:33 AM Product Status Report Product ID Comments Unavailable Soft-Switch Panel ECM Part Number 2437068-00 Software Group

More information

Flight Systems. Replacement for KASSEC DESCRIPTION

Flight Systems.   Replacement for KASSEC DESCRIPTION DESCRIPTION The is a universal generator controller that will start, stop, and provide engine protection for most generators. Universal replacement for both the 90353 and 90354 KASSEC Compatible with most

More information

CORESENSE DIAGNOSTICS FOR STREAM REFRIGERATION COMPRESSORS

CORESENSE DIAGNOSTICS FOR STREAM REFRIGERATION COMPRESSORS Date of last update: Apr-15 Ref: D7.8.4/0112-0415/E Application Engineering Europe CORESENSE DIAGNOSTICS FOR STREAM REFRIGERATION COMPRESSORS CoreSense Diagnostics for Stream Refrigeration Compressors...

More information

RVS-DN Digital Reduced Voltage Motor Starter

RVS-DN Digital Reduced Voltage Motor Starter RVS-DN Digital Reduced Voltage Motor Starter Specification Guide Specification Guide Contents 1.0 Introduction 2.0 Specifications 2.1 Standard Performance Features 2.2 Standard Protection Features 2.3

More information

Application Engineering Europe

Application Engineering Europe Date of last update: Feb-12 Ref: D7.8.4/0112-0212/E Application Engineering Europe CORESENSE DIAGNOSTICS FOR STREAM REFRIGERATION COMPRESSORS 1/17 1 Introduction CoreSense is an ingredient brand name for

More information

DIN-Rail DC UPS. Powers Loads and Charges Back-Up Battery, Ideal for Automation and Wireless System Transmitter Applications

DIN-Rail DC UPS. Powers Loads and Charges Back-Up Battery, Ideal for Automation and Wireless System Transmitter Applications DIN-Rail DC UPS Powers Loads and Charges Back-Up Battery, Ideal for Automation and Wireless System Transmitter Applications Combines all system power functions: power supply, battery charger, UPS circuitry

More information

Rev 29. Caution

Rev 29. Caution 9469200995 Rev 29 communication ports include a mini-b USB port, CAN terminals, and provisions for an optional Remote Display Panel. The following paragraphs describe the communication ports in detail.

More information

Advanced Genset Controller, AGC 200 Display readings Push-button functions Alarm handling Log list

Advanced Genset Controller, AGC 200 Display readings Push-button functions Alarm handling Log list OPERATOR'S MANUAL Advanced Genset Controller, AGC 200 Display readings Push-button functions Alarm handling Log list DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614 Fax: +45 9614 9615 info@deif.com

More information

Operations Manual. Automated Fuel Maintenance System FUEL TECHNOLOGIES INTERNATIONAL

Operations Manual. Automated Fuel Maintenance System FUEL TECHNOLOGIES INTERNATIONAL Operations Manual Automated Fuel Maintenance System FTI-10A & 20A FUEL TECHNOLOGIES INTERNATIONAL Replacement Manuals Available on Website: www.fueltechnologiesinternational.com 07/15/2015 Rev E Fuel Technologies

More information

Issue 2.0 December EPAS Midi User Manual EPAS35

Issue 2.0 December EPAS Midi User Manual EPAS35 Issue 2.0 December 2017 EPAS Midi EPAS35 CONTENTS 1 Introduction 4 1.1 What is EPAS Desktop Pro? 4 1.2 About This Manual 4 1.3 Typographical Conventions 5 1.4 Getting Technical Support 5 2 Getting Started

More information

Cat Electronic Technician 2017A v1.0 Product Status Report 7/10/2017 9:49 AM

Cat Electronic Technician 2017A v1.0 Product Status Report 7/10/2017 9:49 AM Cat Electronic Technician 2017A v1.0 Product Status Report 7/10/2017 9:49 AM Product Status Report Product ID Comments ELIAS MARIN C18 772 (TXH00900) Engine Serial Number TXH00900 ECM Part Number 2622879-01

More information

A problem with the motor windings. A phase loss on mains terminals L1, L2, or L3 during run mode. Parameter 2-3 Current Imbalance Delay.

A problem with the motor windings. A phase loss on mains terminals L1, L2, or L3 during run mode. Parameter 2-3 Current Imbalance Delay. 10 Troubleshooting When a protection condition is detected, the VLT Soft Starter MCD 500 writes this condition to the event log and may also trip or issue a warning. The soft starter response depends on

More information

KEMKRAFT ENGINEERING, INC. MODEL KEI-234 STEERING WHEEL TORQUE/INCLINOMETER TESTER

KEMKRAFT ENGINEERING, INC. MODEL KEI-234 STEERING WHEEL TORQUE/INCLINOMETER TESTER INSTRUCTION MANUAL STEERING WHEEL TORQUE/ INCLINOMETER SYSTEM MODEL KEI-234 W / INTERNAL BARCODE SCANNER REVISION DATE: 17-AUG-1999 1 GENERAL DESCRIPTION... 3 INSTALLATION... 3 SYSTEM SETUP... 4 To change

More information

REVISION HISTORY REVISION HISTORY

REVISION HISTORY REVISION HISTORY FILTER CONTROLLER REVISION HISTORY Filter Flush Controller forms part of the Netafim range of filtration controllers all designed to make filteration more reliable and economical.. Contact any of the Netafim

More information

DKG-109 AUTOMATIC MAINS FAILURE UNIT

DKG-109 AUTOMATIC MAINS FAILURE UNIT Tel: +90-216-466 84 60 Fax: +90-216 364 65 65 datakom@datakom.com.tr http://www.datakom.com.tr DKG-109 AUTOMATIC MAINS FAILURE UNIT FEATURES Automatic mains failure Engine control Generator protection

More information

INSTALLATION AND MAINTENANCE MANUAL FOR DIESEL ENGINE FIRE PUMP CONTROLLERS AUTOMATIC CONTROLLER

INSTALLATION AND MAINTENANCE MANUAL FOR DIESEL ENGINE FIRE PUMP CONTROLLERS AUTOMATIC CONTROLLER INSTALLATION AND MAINTENANCE MANUAL FOR DIESEL ENGINE FIRE PUMP CONTROLLERS AUTOMATIC CONTROLLER MODEL GPD 1 Table of Contents 1. Introduction 2. Installation 3. Main Features 4. Home 5. Alarms 6. Configuration

More information

RVS-DX Digital Reduced Voltage Motor Starter

RVS-DX Digital Reduced Voltage Motor Starter RVS-DX Digital Reduced Voltage Motor Starter Specification Guide Specification Guide Contents 1.0 Introduction 2.0 Specifications 2.1 Standard Performance Features 2.2 Standard Protection Features 2.3

More information

INSTALLATION AND MAINTENANCE MANUAL FOR DIESEL ENGINE FIRE PUMP CONTROLLERS MODEL GPD

INSTALLATION AND MAINTENANCE MANUAL FOR DIESEL ENGINE FIRE PUMP CONTROLLERS MODEL GPD INSTALLATION AND MAINTENANCE MANUAL FOR DIESEL ENGINE FIRE PUMP CONTROLLERS MODEL GPD 1 Table of Contents 1. Introduction 2. Installation 3. Main Features 4. Home 5. Alarms 6. Configuration 7. History

More information

Section 55 Chapter 6

Section 55 Chapter 6 Section 55 Chapter 6 REMOTE HYDRAULICS CONTROLLER Calibration and Fault Codes 6-12880NH TABLE OF CONTENTS REMOTE HYDRAULICS CONTROLLER CALIBRATION... 55-5 Requirements For Calibration... 55-5 Aux Set Main

More information

Deep Sea Electronics Plc

Deep Sea Electronics Plc Deep Sea Electronics Plc 5120 AUTOMATIC MAINS FAILURE MODULE OPERATING MANUAL Author: Anthony Manton Deep Sea Electronics Plc Highfield House Hunmanby North Yorkshire YO14 0PH England Tel: +44 (0) 1723

More information

5220 AUTOMATIC MAINS FAILURE MODULE OPERATING MANUAL

5220 AUTOMATIC MAINS FAILURE MODULE OPERATING MANUAL 5220 AUTOMATIC MAINS FAILURE MODULE OPERATING MANUAL > Section DSE Model 5220 Automatic Mains Failure & Instrumentation System Operators Manual TABLE OF CONTENTS

More information

Cascade CD101 Auto-Start Controller. Installation and Operations Manual Sections 40 & 75

Cascade CD101 Auto-Start Controller. Installation and Operations Manual Sections 40 & 75 Cascade CD101 Auto-Start Controller Installation and Operations Manual 00-02-0594 2018-02-15 Sections 40 & 75 In order to consistently bring you the highest quality, full featured products, we reserve

More information

Caterpillar Electronic Technician 2012C v1.0 Product Status Report 9/28/2017 8:32 AM

Caterpillar Electronic Technician 2012C v1.0 Product Status Report 9/28/2017 8:32 AM Page 1 of 8 Caterpillar Electronic Technician 2012C v1.0 Product Status Report 8:32 AM Product Status Report Comments C18 D9 (RHX01781) Engine Serial Number RHX01781 24556258JL Personality Module Part

More information

TG350 User Manual. Manual Revision: Min. FW Revision: Date Released: 09/01/ DYNAGEN Technologies Inc

TG350 User Manual. Manual Revision: Min. FW Revision: Date Released: 09/01/ DYNAGEN Technologies Inc TG350 User Manual Manual Revision: 1.4.0 Min. FW Revision: 1.42.01 Date Released: 09/01/2014 Table of Contents 1 Introduction 1.1 Specifications... 3 2 Installation 2.1 Terminal s... 6 2.2 Typical Wiring...

More information

DKG-109J AUTOMATIC MAINS FAILURE UNIT

DKG-109J AUTOMATIC MAINS FAILURE UNIT DKG-109J AUTOMATIC MAINS FAILURE UNIT CANBUS VERSION FEATURES True RMS measurements Automatic mains failure ECU control and monitoring through J1939 CAN J1939 ECU warnings displayed as text Various engine

More information

Modbus Register Map:Galaxy VM (3: kVA 400/480V)

Modbus Register Map:Galaxy VM (3: kVA 400/480V) Modbus Register Map:Galaxy VM (3:3 50-225kVA 400/480V) Part number: 990-9692 Notes:. 6-bit registers are transmitted MSB first (i.e. big-endian). 2. INT32 and UINT32 are most-significant word in n+0, least

More information

Modbus Integration Integration for Modbus Functionality for VT8600 Series

Modbus Integration Integration for Modbus Functionality for VT8600 Series Modbus Integration Integration for Modbus Functionality for VT8600 Series Building Management System *For data visualization and analysis Modbus Controller VT8000 Series room controllers 2 TABLE OF CONTENTS

More information

MANUAL ELECTRIC FIRE PUMP CONTROLLERS METRON SERIES M450

MANUAL ELECTRIC FIRE PUMP CONTROLLERS METRON SERIES M450 MANUAL ELECTRIC FIRE PUMP CONTROLLERS METRON SERIES M450 TABLE OF CONTENTS PART I GENERAL DESCRIPTION... PAGE 2 PART II FUNCTIONS... PAGE 2 PART III INSTALLATION... PAGE 3 PART IV INITIAL INSTALLATION

More information

DGC-2020 DIGITAL GENSET CONTROLLER

DGC-2020 DIGITAL GENSET CONTROLLER DIGITAL GENSET CONTROLLER Basler Electric s Digital Genset Controller (DGC-2020) is a highly advanced integrated genset control system. The DGC-2020 is perfectly focused, combining rugged construction

More information

AC drive has detected too high a Check loading

AC drive has detected too high a Check loading Fault code Fault Name Fault type Default Possible Cause Remedy 1 Over Current Fault AC drive has detected too high a Check loading current (>4*IH) in the motor cable: Check motor Sudden heavy load increase

More information

An ISO 9001:2008 Registered Company

An ISO 9001:2008 Registered Company An ISO 9001:2008 Registered Company Introduction Engine Monitor System 2009-2018 Ford E Series (EMS501-D) 2008-2010 Ford F250-550 6.2L, 6.8L (EMS506-D) 2011-2016 Ford F250-550 6.2L, 6.8L (EMS507-D) 2017

More information

DRAFT 1400HP 1000HP 100HP. Reduced Voltage Solid State Starters. Softstarters SOFT. PF Controller PCS Controller PDS Controller V 1...

DRAFT 1400HP 1000HP 100HP. Reduced Voltage Solid State Starters. Softstarters SOFT. PF Controller PCS Controller PDS Controller V 1... 100HP 400HP 700HP 1000HP 1400HP PCS Softstarter Controller IN-rail mountable microprocessor controller for 3-phase motors up to 480A (3...85A din-rail mountable) Provides three different starting modes

More information

MaxxForce DT, 9, 10 ( )

MaxxForce DT, 9, 10 ( ) MaxxForce DT, 9, 10 (2007-2009) Overview: Idle Shutdown Timer (Non-CARB Certified Engines) NAV_IST_030711 Idle Shut Down Timer TABLE OF CONTENTS General Overview: Idle Shutdown Timer... 1 Description and

More information

WITH AUTOMATIC TRANSFER SWITCH

WITH AUTOMATIC TRANSFER SWITCH INSTALLATION AND MAINTENANCE MANUAL FOR ELECTRIC PUMP CONTROLLERS WITH AUTOMATIC TRANSFER SWITCH MODEL GPL + GLU 1 Table of Contents 1. Introduction 2. Installation 3. Main Features 4. Home 5. Alarms 6.

More information

DKG-509 AUTOMATIC MAINS FAILURE UNIT

DKG-509 AUTOMATIC MAINS FAILURE UNIT DKG-509 AUTOMATIC MAINS FAILURE UNIT CANBUS AND MPU VERSIONS DESCRIPTION The controller is a comprehensive AMF unit for single genset standby or dual genset mutual standby operations. The unit is available

More information

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION Fire Pump Acceptance Inspection Date of Review / / BLD20 - Project Address: Project Name: Numbers following worksheet comments represent an NFPA

More information

IPC-PC Intelligent Pump Control Operation Manual

IPC-PC Intelligent Pump Control Operation Manual IPC-PC Intelligent Pump Control Operation Manual OEM Original Equipment Manufacturer Stewart & Stevenson Control System Group 10750 Telge Road Houston, Texas 77095 Stewart & Stevenson Services, Inc. Introduction

More information

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting POWER+ PREMIUM CBS CENTRALIZED Battery System BS-EN-50171 Emergency electrical installations Electric power systems Emergency lighting Escape lighting POWER+ PREMIUM CBS 10KVA-40KVA The systems running

More information

Submittal Data Information

Submittal Data Information Effective: NOVEMBER 3, 2014 JOB CONTRCTOR ITEM NO. Submittal Data Information TS - Taco dvanced Starter ENGINEER REP. 301-2690 Supersedes: NEW TS - Taco dvanced Starter 1Ø, 120-230V, 1/10-30HP 3Ø, 200-600V,

More information

Spartan Controls Millennium Compressor Control Panel Operating Philosophy

Spartan Controls Millennium Compressor Control Panel Operating Philosophy Project: Stock Revision 1 Page 1 Spartan Controls Millennium Compressor Control Panel Operating Philosophy Location: Stock Customer references: Vendor: Vendor document: Spartan Controls Ltd. Operating

More information

GENSET PRODUCTS 013 2

GENSET PRODUCTS 013 2 GENSET PRODUCTS 2013 TECHNOLOGY IS NOW FOR EVERYONE D 700 COMMUNICATION CAPABILITIES AUTOMATIC MAINS FAILURE UNITS DKG 107 DKG 107 The lowest cost AMF module Factory set timers Adjustable AC low voltage

More information

TECHNICAL PAPER 1002 FT. WORTH, TEXAS REPORT X ORDER

TECHNICAL PAPER 1002 FT. WORTH, TEXAS REPORT X ORDER I. REFERENCE: 1 30 [1] Snow Engineering Co. Drawing 80504 Sheet 21, Hydraulic Schematic [2] Snow Engineering Co. Drawing 60445, Sheet 21 Control Logic Flow Chart [3] Snow Engineering Co. Drawing 80577,

More information

TIME REQUIREMENT GUIDE (TRG)

TIME REQUIREMENT GUIDE (TRG) CAT SWITCHGEAR TIME REQUIREMENT GUIDE (TRG) This warranty repair time requirement guide is designed to: Provide detailed guidance on troubleshooting Determine possible solutions Guide the technician to

More information

X11CA-IM MASTER MODULE

X11CA-IM MASTER MODULE X11CA-IM MASTER MODULE (Firmware: X11-MF3 Rev. 3) REVISION : 2.0 DOCUMENT NUMBER : X11CA-3000-IOM DATE : April 21, 2003 EDITOR : Nana Lee Ronan Engineering Company APPROVED : Kevin Safayieh 4/23/03 Project

More information

Indian Speedometer and Body Control Module Service Tool Users Guide

Indian Speedometer and Body Control Module Service Tool Users Guide Indian Speedometer and Body Control Module Service Tool Users Guide Installing speedometer software to your computer 1. Go to the Indian Motorcycle Website: WWW. Indianmotorcycle.com 2. Log in to Service

More information

CTi Automation - Phone: Fax: Web:

CTi Automation - Phone: Fax: Web: CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net The control & protection you expect in an innovative soft starter design... Flexibility

More information

Installation and Operations Manual

Installation and Operations Manual Excalibur Water Systems 3.0 High Capacity Superflow Series QUADPLEX Water Softener Installation and Operations Manual 142 Commerce Park Drive, Units M-O, Barrie ON L4N 8W8 www.excaliburwater.com Water

More information

Continuing Education Course #206 Introduction to Designing Machine Control Systems Part 2

Continuing Education Course #206 Introduction to Designing Machine Control Systems Part 2 1 of 5 Continuing Education Course #206 Introduction to Designing Machine Control Systems Part 2 1. Continuing to answer the following questions indicates that you understands that the presented material

More information

FRICK QUANTUM HD COMPRESSOR CONTROL PANEL

FRICK QUANTUM HD COMPRESSOR CONTROL PANEL Operation Form 090.040-O (AUG 2014) File: SERVICE MANUAL - Section 90 Replaces: 090.040-O (JUNE 2013) Dist: 3, 3a, 3b, 3c FRICK QUANTUM HD COMPRESSOR CONTROL PANEL Version 10.16 CURRENT DESIGN AUGUST 2014

More information

ELM327 OBD to RS232 Interpreter

ELM327 OBD to RS232 Interpreter OBD to RS232 Interpreter Description Almost all new automobiles produced today are required, by law, to provide an interface from which test equipment can obtain diagnostic information. The data transfer

More information

HGM6320T AUTOMATIC GENERATOR CONTROLLER USER MANUAL

HGM6320T AUTOMATIC GENERATOR CONTROLLER USER MANUAL HGM6320T AUTOMATIC GENERATOR CONTROLLER USER MANUAL Smartgen Technology Smartgen Technology Co., Ltd No. 28 Jinsuo Road Zhengzhou Henan Province P. R. China Tel: 0086-371-67988888/67981888 0086-371-67991553/67992951/67992952

More information

Fuel Cell Lab Manual. Non Conventional Energy Systems Facility. Non Conventional Energy Systems Facility. Boiler House

Fuel Cell Lab Manual. Non Conventional Energy Systems Facility. Non Conventional Energy Systems Facility. Boiler House Fuel Cell Lab Manual Non Conventional Energy Systems Facility Boiler House Department of Mechanical Engineering IIT Kanpur System Description The Nexa system provides up to 1200 watts of unregulated DC

More information

8 Troubleshooting and Maintenance

8 Troubleshooting and Maintenance 8 Troubleshooting and Maintenance 8.1 Troubleshooting 8.1.1 Troubleshooting of LED Indicators See Tab. 7-4 State Descriptions of LED Indicators for the definition. Fault Type LED indicators and LCD screen

More information

HGM6320T AUTOMATIC GENERATOR CONTROLLER USER MANUAL

HGM6320T AUTOMATIC GENERATOR CONTROLLER USER MANUAL HGM6320T AUTOMATIC GENERATOR CONTROLLER USER MANUAL Smartgen Technology CONTENT 1 SUMMARY... 4 2 PERFORMANCE AND CHARACTERISTICS... 4 3 SPECIFICATION... 5 4 OPERATION... 6 4.1 LCD DISPLAY... 6 4.2 KEY

More information

702 AUTOMATIC START MODULE OPERATING INSTRUCTIONS

702 AUTOMATIC START MODULE OPERATING INSTRUCTIONS 702 AUTOMATIC START MODULE OPERATING INSTRUCTIONS > TABLE OF CONTENTS 1 DESCRIPTION OF OPERATION... 4 1.1 MANUAL MODE OPERATION... 4 1.2 AUTOMATIC MODE OF OPERATION...

More information

Application Note RESIDUAL BUS MAIN-TIE-MAIN AUTOMATIC TRANSFER SCHEME USING THREE GE 850 RELAYS

Application Note RESIDUAL BUS MAIN-TIE-MAIN AUTOMATIC TRANSFER SCHEME USING THREE GE 850 RELAYS Application Note GET-8558 RESIDUAL BUS MAIN-TIE-MAIN AUTOMATIC TRANSFER SCHEME USING THREE GE 850 RELAYS REVISION 01 March 17 th, 2016 1 INDEX 1. INTRODUCTION 4 2. RELAY ORDER CODE 5 3. RELAY IO CONNECTIONS

More information

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning. Introduction OPERATING INSTRUCTIONS: MCD REMOTE OPERATOR Order Codes: 175G94 (for MCD 2) 175G361 + 175G9 (for MCD 5) 175G361 (for MCD 3) 1. Introduction 1.1. Important User Information Observe all necessary

More information

ELM327 OBD to RS232 Interpreter

ELM327 OBD to RS232 Interpreter OBD to RS232 Interpreter Description Almost all new automobiles produced today are required, by law, to provide an interface from which test equipment can obtain diagnostic information. The data transfer

More information

PowerCommand. ModLon II Gateway. Specifications. ModBus LON Converter

PowerCommand. ModLon II Gateway. Specifications. ModBus LON Converter PowerCommand ModLon II Gateway ModBus LON Converter Description The PowerCommand ModLon II Gateway is used to interface PowerCommand networks to devices and systems that communicate in Modbus communication

More information

Caterpillar Electronic Technician 2012C v1.0 Product Status Report. 12-Mar :40 PM

Caterpillar Electronic Technician 2012C v1.0 Product Status Report. 12-Mar :40 PM Page 1 of 11 Caterpillar Electronic Technician 2012C v1.0 Product Status Report 12-Mar-2013 1:40 PM Product Status Report Comments Monitor ECM Part Number 2395025-09 2897B667HL Software Group Part Number

More information

ITCEMS950 Idle Timer Controller - Engine Monitor Shutdown Isuzu NPR 6.0L Gasoline Engine

ITCEMS950 Idle Timer Controller - Engine Monitor Shutdown Isuzu NPR 6.0L Gasoline Engine Introduction An ISO 9001:2008 Registered Company ITCEMS950 Idle Timer Controller - Engine Monitor Shutdown 2014-2016 Isuzu NPR 6.0L Gasoline Engine Contact InterMotive for additional vehicle applications

More information

ECO3-601/602 EcoStar III * Chevy Express/GMC Savana Contact Intermotive for additional vehicle applications

ECO3-601/602 EcoStar III * Chevy Express/GMC Savana Contact Intermotive for additional vehicle applications An ISO 9001:2015 Registered Company ECO3-601/602 EcoStar III 2009-2019* Chevy Express/GMC Savana Contact Intermotive for additional vehicle applications * In 2017-2018, the ignition switches on Chevy Express

More information

Cat Electronic Technician 2016C v1.0 Product Status Report 3/6/ :16 AM

Cat Electronic Technician 2016C v1.0 Product Status Report 3/6/ :16 AM Cat Electronic Technician 2016C v1.0 Product Status Report 3/6/2017 10:16 AM Product Status Report Parameter Product ID Equipment ID Comments Value PAC01146 Monitor Parameter Value ECM Serial Number 067E0525EE

More information

Acu-Trac Ultrasonic Fuel Level Transmitters

Acu-Trac Ultrasonic Fuel Level Transmitters General SSI s Acu-Trac ultrasonic fuel level transmitters broadcast and receive commands over the SAE J1708 serial data link enabling the level transmitters to communicate and share data with other modules

More information

Standby Power Systems

Standby Power Systems Source: Power Quality in Electrical Systems Chapter 13 Standby Power Systems The term standby power systems describes the equipment interposed between the utility power source and the electrical load to

More information

Wallbox Commander. User Guide WBCM-UG-002-EN 1/11

Wallbox Commander. User Guide WBCM-UG-002-EN 1/11 Wallbox Commander User Guide 1/11 Welcome to Wallbox Congratulations on your purchase of the revolutionary electric vehicle charging system designed with cuttingedge technology to satisfy your daily needs.

More information

EPAS Desktop Pro Software User Manual

EPAS Desktop Pro Software User Manual Software User Manual Issue 1.10 Contents 1 Introduction 4 1.1 What is EPAS Desktop Pro? 4 1.2 About This Manual 4 1.3 Typographical Conventions 5 1.4 Getting Technical Support 5 2 Getting Started 6 2.1

More information

Softstarters. Softstarters Type SSM Medium voltage ,800V 1

Softstarters. Softstarters Type SSM Medium voltage ,800V 1 Medium voltage 2300 13,800V 1 Description Fused disconnect switch with blown fuse indicators and door safety interlocks rated for load break/fault make with automatic grounding arm Inline isolation vacuum

More information

DEEP SEA ELECTRONICS PLC

DEEP SEA ELECTRONICS PLC COMPLEX SOLUTIONS MADE SIMPLE. DEEP SEA ELECTRONICS PLC DSE5110 AUTOSTART CONTROL MODULE OPERATING MANUAL Deep Sea Electronics Plc Highfield House Hunmanby North Yorkshire YO14 0PH ENGLAND Sales Tel: +44

More information

Application Engineering

Application Engineering Application Engineering February, 2009 Copeland Digital Compressor Controller Introduction The Digital Compressor Controller is the electronics interface between the Copeland Scroll Digital Compressor

More information

HGM7100N SERIES (HGM7110N/7120N) GENSET CONTROLLER USER MANUAL

HGM7100N SERIES (HGM7110N/7120N) GENSET CONTROLLER USER MANUAL HGM7100N SERIES (HGM7110N/7120N) GENSET CONTROLLER USER MANUAL SMARTGEN (ZHENGZHOU) TECHNOLOGY CO., LTD. Chinese trademark English trademark SmartGen make your generator smart SmartGen Technology Co.,

More information

EVO AT SERIES BATTERY CHARGER

EVO AT SERIES BATTERY CHARGER EVO AT SERIES BATTERY CHARGER AT SERIES BATTERY CHARGER P R O D U C T PATENT PENDING hindlepowerinc.com 610-330-9000 Evo AT Series battery charger designed with YOU in mind. Evo AT Series battery charger

More information

EVO SERIES BATTERY CHARGER SERIES BATTERY CHARGER

EVO SERIES BATTERY CHARGER SERIES BATTERY CHARGER EVO SERIES BATTERY CHARGER SERIES BATTERY CHARGER Evo Series battery charger designed with YOU in mind. Evo Series battery charger is a next generation SCR-based utility battery charger. This evolutionary

More information

Option M4 Engine control and protection Functional description Modes and sequences General product information PID controller Additional functions

Option M4 Engine control and protection Functional description Modes and sequences General product information PID controller Additional functions DESCRIPTION OF OPTIONS Option M4 Engine control and protection Modes and sequences General product information PID controller Additional functions DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614

More information

AT EVO SERIES BATTERY CHARGER

AT EVO SERIES BATTERY CHARGER STANDARD FEATURES 5 YEAR WARRANTY EVO AT Series Battery Charger is HindlePower s next generation SCR-based utility battery charger. This evolutionary product is revolutionary in its design and operation

More information

Cat Electronic Technician 2016B v1.0 Product Status Report 1/30/2017 3:49 PM

Cat Electronic Technician 2016B v1.0 Product Status Report 1/30/2017 3:49 PM Page 1 of 7 Cat Electronic Technician 2016B v1.0 Product Status Report 1/30/2017 3:49 PM Cat Monitor System AP1055 () C7 AP1000 Series (KHX01992) Machine Control AP1055 Product Status Report Equipment

More information

ANALOG CONTROL PANEL

ANALOG CONTROL PANEL ANALOG CONTROL PANEL 1. AC VOLTS: Displays generator output in voltage. 2. AC FREQUENCY: Displays the speed of the generator set in Hertz. 3. Percent of Load: Displays percentage of load on the generator.

More information

TRIPS AND FAULT FINDING

TRIPS AND FAULT FINDING WWW.SDS.LTD.UK 0117 9381800 Trips and Fault Finding Chapter 6 6-1 TRIPS AND FAULT FINDING Trips What Happens when a Trip Occurs When a trip occurs, the drive s power stage is immediately disabled causing

More information

Digital Diesel Control Remote control panel for GENVERTER GV4 and GV7i

Digital Diesel Control Remote control panel for GENVERTER GV4 and GV7i OPERATING MANUAL Digital Diesel Control Remote control panel for GENVERTER GV4 and GV7i Art. nr. 40200801 WHISPER POWER BV ENGLISH: PAGE 1 Kelvinlaan 82 9207 JB Drachten NEDERLANDS: PAGINA 41 Netherlands

More information

Vission 20/20 micro-controller. Operation and service manual Version 2.6

Vission 20/20 micro-controller. Operation and service manual Version 2.6 Vission 20/20 micro-controller Operation and service manual Version 2.6 Important Message READ CAREFULLY BEFORE OPERATING YOUR COMPRESSOR. The following instructions have been prepared to assist in operation

More information

DEEP SEA ELECTRONICS PLC

DEEP SEA ELECTRONICS PLC DEEP SEA ELECTRONICS PLC 703 AUTOMATIC START MODULE OPERATING INSTRUCTIONS Author:- John Ruddock 703 Operating Instructions Issue Beta1 25/08/2003 2:45 PM JR - 1 - >

More information

DEEP SEA ELECTRONICS PLC DSE3210 Configuration Suite Software Manual

DEEP SEA ELECTRONICS PLC DSE3210 Configuration Suite Software Manual DEEP SEA ELECTRONICS PLC DSE3210 Configuration Suite Software Manual Document Number 057-152 Author : Paul Gibbons DSE3210 Configuration Suite Software Manual Issue 1 DSE3210 Configuration Suite Software

More information

Cannondale Diagnostic Tool Manual

Cannondale Diagnostic Tool Manual Cannondale Diagnostic Tool Manual For vehicles (ATV & Motorcycles) equipped with the MC1000 Engine Management System Software CD P/N 971-5001983 Data Cable P/N 971-5001984 POTENTIAL HAZARD Running the

More information

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. The Defender Mini CLI specification describes a single phase, online, solid state Lighting

More information

825-P Modular Protection System for motors Specification Guide

825-P Modular Protection System for motors Specification Guide Specification Guide 1.0 General 1.01 The motor protection relay shall have a current operating range of 0.5 and 5000 amperes. 1.02 The motor protection relay shall provide current measurement-based protection

More information

Wide Bank 28 DS3 QUICK START GUIDE

Wide Bank 28 DS3 QUICK START GUIDE Wide Bank 28 DS3 QUICK START GUIDE Product Number: 002-0139-0500 Product Release: 2.4 July 2004 Copyright 2004 Carrier Access Corporation. All rights reserved. The information presented in this manual

More information