Document No. HIMURJA (F-7) / SPV Plant / RTS /

Size: px
Start display at page:

Download "Document No. HIMURJA (F-7) / SPV Plant / RTS /"

Transcription

1 Document No. HIMURJA (F-7) / SPV Plant / RTS / RATE CONTRACT (Under Empanelment Scheme) Design, manufacture, supply, erection, testing and Commissioning including warranty, operation & maintenance for 5 years of 1 kwp to 500 kwp Grid connected Rooftop Solar Power Plants under the Grid Interactive Rooftop Solar Power Plants scheme of MNRE and the Solar Power Policy in the State of Himachal Pradesh to be installed on the roofs of Govt. buildings of different capacities (having an aggregate capacity of 2.5 MWp in Shimla city & 2 MW all over state) & for Domestic, Institution (registered under society/trust act) and Social Sector buildings in the State. HIMURJA H.P. Govt. Energy Development Agency 8-A,SDA Complex, Kasumpti, Shimla Himachal Pradesh, INDIA Telephone No: Fax No: Website:- Himurja.nic.in

2 Rate contract for Grid interactive rooftop Solar PV Power Plant A. NECESITY FOR THE RATE CONTRACT Ministry of New and Renewable Energy, Govt of India is promoting Grid connected Rooftop Solar Power plants in the country and sanction has been accorded by the Ministry for installing GCRTS in the State. To achieve the Targets fixed for H.P. State, HIMURJA will empanel firms for the Design, manufacture, supply, erection, testing and commissioning including warranty, operation & maintenance for 5 years of Rooftop Solar Power plant of capacities varying from 1 kwp to 500 kwp in the State of Himachal Pradesh. MNRE, GoI has revised the benchmark cost for the year accordingly tender is floated for rate contract to the Registered Firms for the supply, installation and commissioning of Grid connected Rooftop Solar Power Plants to be installed on the roofs of Govt. buildings of different capacities (capacity of 2.5 MWp in Shimla city & 2 MW all over the State) and Domestic, Institution (registered under society/trust act) and Social Sector buildings in the State. B. SUBSIDY PATERN: i) Capital subsidy upto maximum 70% of the benchmark cost of the system as per the latest notification of MNRE is available for all rooftops of Domestic, Institution (registered under society/trust act) and Social Sector buildings in the State. Apart from this a State subsidy of Rs 4000=00 per kwp is available for these buildings. ii) For Government buildings / Institutions the subsidy is progress linked and will be almost 60% in case the scheme is completed within the stipulated period, failing which liable to be reduced in percentage as per MNRE, GoI, norms. C. SCOPE OF WORK: HIMURJA invites bids for rate contract for design, manufacture, supply, erection, testing and commissioning including warranty, operation & maintenance for 5 years of Grid Interactive Rooftop Solar Power Plants of capacities varying from 1 kwp to 500 kwp in the State of Himachal Pradesh, to be installed on the roofs of Govt. buildings of different capacities (capacity of 2.5 MWp in Shimla city & 2 MW all over the State) & also for rate contract for installation of

3 Rooftop Solar Plants at domestic/institution (registered under society/trust act)/social sector buildings under empanelment scheme in the State; from the experienced Solar Power plant EPC contractor, Manufacturer of Solar modules or Inverter. The tender document can be purchased from the office of Himurja at Shimla by paying Rs. 10,000/- only in the shape of demand draft drawn in favour of Director, HIMURJA, Shimla from to The tender document shall be received/ submitted up to Hours on dated and will be opened on the same day at 3 PM in the presence of the bidders or their authorized representatives who may like to be present. The bid documents can also be downloaded from the website of HIMURJA i.e. himurja.nic.in. The cost of the documents in that case can be deposited along with the bid in the shape of demand draft in favour of Director, HIMURJA, Shimla separately. The rates will be applicable to all the Firms empanelled with HIMURJA who wish to provide their services on the lowest quoted prices which are received under this offer. The selected firms will have the opportunity to execute the projects for which the sites can be identified by the firms or on the sites allocated by HIMURJA under the Grid Interactive Roof top Solar Power Plants in accordance with technical specifications and various other requirements as per latest directions / guidelines of MNRE, GoI under NSM. The various group of size / capacity of the grid interactive rooftop solar power plant shall be as under: S.No. Group of Size/capacity Location 1. Upto 10 kwp 2 >10 kwp to 50 kwp 3 >50 kwp to 100 kwp Anywhere in the state of Himachal Pradesh 4 >100 kwp to 300 kwp 5 >300 kwp to 500 kwp HIMURJA will provide the applicable CFA to the registered firms based on the lowest rates received under this tender and subject to the release of funds by Ministry, GOI. The empanelled firms will design, manufacture, supply, erect, test and commission and make all necessary arrangement for evacuation and injection of surplus power to the HPSEBL grid at the interconnection point.

4 D. SITE / PROJECT LOCATION It is important to note that under the Grid Interactive Roof Top Solar Power Plants Scheme the projects of various capacities from 1 kwp to 500 kwp can be allotted depending upon the sites identified. The firms can also be given specific targets so as to implement the programme in a time bound manner. The firms will also be at liberty to identify buildings or find potential beneficiaries to achieve the allotted targets. HIMURJA will also from time to time identify buildings / beneficiaries which will be made known to the empanelled firms. D. INFORMATION TO THE FIRM / BIDDER 1. Earnest Money / Security Amount:- 1.1 Bid accompanied by earnest money/ bid security of Rs. 1,00,000=00( Rupees One Lac only) through demand draft only shall be accepted. 1.2 The earnest money / bid security is required to protect the HIMURJA against risk of Bidder's conduct which would warrant the security's forfeiture. No interest will be paid on Earnest Money. 1.3 Unsuccessful Bidder's earnest money / bid security will be discharged / returned as promptly possible as but not later than thirty (30) days after the expiration of the period of bid validity prescribed by the HIMURJA subject to receipt of request letter from the bidder. 1.5 The bid security may be forfeited: a) If a Bidder withdraws its bid during the period of bid validity specified by the Bidder on the Bid Form. b) In case successful Bidder fails to sign the Contract or to furnish required performance security. 1.6 The Earnest Money/Security Amount of the empanelled firms will be refunded after the completion of duration of empanelment. 2. Duration of Empanelment 2.1 The selected firms / bidders will be empanelled initially for a period of one year. After completion of this period, the validity of rates may further be extended on the basis of performance of the consultant firm and mutual consent between HIMURJA and interested empanelled firms. 2.2 The firms will be registered within one month from the date of finalization of lowest rates.

5 3. Payments Empanelled firms will have to supply and install the Solar Power Plants on the rates approved by HIMURJA in each group and will get payment as under: % of the CFA as applicable, due from MNRE, shall be paid after successful installation, commissioning of the Solar PV Power Plant and injection of surplus power (if any) into the HPSEBL grid confirming to technical specifications as specified in this tender. The CFA will be given as per the prescribed MNRE benchmark cost from time to time. 3.2 The amount due from the beneficiary (30% of the total cost) will be taken by the firm directly in case the beneficiary has been identified by them and in case the beneficiary has been selected by HIMURJA the amount will be paid by HIMURJA immediately after installation and commissioning of Solar PV Power Plant. In case of GCRT plant installed on Govt buildings no beneficiary share has to be taken and the full payment will be made by HIMURJA. 3.3 Balance 10% of the CFA shall be treated as performance security and shall be paid against satisfactory performance of the Solar PV Power Plant during warrantee, operation and maintenance period. This amount shall be paid to firm after completion of five year from the date of Commissioning at site. The bidder shall have to submit performance & functionality report to HIMURJA for the release of this payments duly verified by the concerned Project Officer HIMURJA. 3.4 The firms will have to supply & install the Rooftop Solar Plant at the site of beneficiaries within 60 days of receipt of funds from the beneficiary, failing which the liquidated damages shall be 1 % per week, 5% of the contract price 1% for delay of 1 2% for delay of two 3% for delay of three 4% for delay of four week 5% for delay of five week and will be recovered from any sums due to the firm. 4. Eligibility criteria 4.1 The Bidder should have sufficient funds and technical expertise for the installation of Grid connected Rooftop Plants in the State. 4.2 The Bidder should have a Service centre in the State for carrying out repair and maintenance of the Plant. The details of the service centre is to be mentioned in the bid. 5. Clarification of Bids 5.1 During evaluation of the bids, the HIMURJA may, at its discretion, ask the Bidder for a clarification of its bid. The request for clarification and the response shall be in writing, and no change in the prices or substance of the bid shall be sought, offered, or permitted.

6 If the firm does not respond to the clarification, the firm will be considered as nonresponsive and the bid shall be rejected out rightly. 5.2 At any time prior to the submission of the bid or prior to the opening of the financial bid HIMURJA may for any reason whether at its own initiative or in response to a clarification requested by the bidders may modify the bid document by amendments. The amendment will be notified in writing or by fax to all prospective bidders who have received the bid documents and will be binding on them. HIMURJA will bear no responsibility or liability arising out of non receipt of the same in time or otherwise. 6. Evaluation and Comparison of Bids 6.1 HIMURJA will evaluate and compare bids which have been determined to be substantially responsive. 6.2 The detailed techno-commercial analysis of the bid shall be carried out by the HIMURJA. 7. HIMURJA's Right to Accept Any Bid and to Reject Any or All Bids 7.1 The HIMURJA reserves the right to accept or reject any bid, and to cancel the bidding process and reject all bids at any time prior to award of Contract, without thereby incurring any liability to the affected Bidder or Bidders or any obligation to inform the affected Bidder or Bidders. 8. Opening of Technical Bids by HIMURJA 8.1 The HIMURJA will open the technical bids, in the presence of Bidders' representatives who want to be present, at the time, on the date, and at the place specified in the Bid Data Sheet. The bidder s representatives present during the opening of the bid, shall sign a register evidencing their attendance. 8.2 The Bidders' names, the presence or absence of the requisite bid security and such other details as the HIMURJA, at its discretion, may consider appropriate will be announced at the opening, except for late bids, which shall be returned unopened to the Bidder. 8.3 The technical bids shall be evaluated by the HIMURJA for assessing responsiveness, bidders qualification and technical confirmation. 8.4 The bidders whose technical bids are declared as technically responsive and qualified shall be informed accordingly and their Price Bids shall be opened. 8.5 The bidders whose technical bids do not qualify, their Price Bids shall not be opened and the same shall be returned to the Bidders. Moreover, such bidders shall not be empanelled at lowest cost in future.

7 8.6 Price Bids opening date shall be conveyed subsequently. 9. Signing of Contract The successful Bidder will sign the contract within thirty (30) days from the date of issue empanelment letter. 10 Selection of bidder(s) for empanelment i. The lowest quoted rates by any bidder for every group of size / capacity will be taken as a base rate. ii. HIMURJA will empanel the technically qualified bidders who agree to work on the lowest quoted rates (base rate) in each group of size / capacity of the project. iii. The list of the successful empanelled bidder / firm will be placed on the website of HIMURJA for the information of the beneficiaries.

8 TECHNICAL SPECIFICATION Technical specifications of the Grid Interactive Rooftop Solar Power plant shall be in accordance to the latest MNRE, GoI technical specifications as issued vide notification no.30/11/ /nsm dated 26/06/14 or as directed by MNRE, GoI for the grid interactive rooftop and small SPV power plant from time to time. 1 Brief Description of the System The main components of the SPV plant are PV Modules Civil Work. Module Mounting Structure Array Junction Boxes String Monitoring Boxes Grid Tie Inverters Solar Meter Step- up Transformer LT Step- up Transformer HT SCADA / Monitoring System as per predefined parameters for higher capacity plants Earth System Lightning & Surge Protection DC Cables. AC Cables. Illumination System AC Metering and Grid Interconnection System. This list is of general nature and some of the components may not be required or may be combined as per the system finally designed. 2. Typical Power Generation Scheme The system consists mainly of the following: Solar PV array which produces DC electricity when solar rays incident on it Power Conditioning Units (PCU) or Inverters which convert DC (Direct Current) electricity into AC (Alternating Current) electricity and facilitate synchronization with the grid power and has all the required protections as mentioned in the Net Metering Regulations. The copy of the Net Metering Regulations is available on the website of Himurja i.e.

9 Transformers which transform the AC output of the Power Conditioning Units to the level required at the grid The SPV array (constituting solar PV modules of selected rating connected in series and parallel combinations to build up the Voltage and Current parameters as per desired design modalities ) produces DC electricity when Solar insolation is incident on it. The DC power thus produced is taken through various junction boxes and isolators and connected to the Inverter. The Inverter houses the inverter circuitry which converts DC power supply into AC power supply, the synchronization circuitry which actualizes the tie-up of solar PV source to the grid source and the remote monitoring and control circuitry. A number of Inverters are connected in parallel as per the desired AC Power required. Depending on the grid voltage level to which the solar PV power is being synchronized, different levels of step-up transformers may have to be deployed. The protection and metering circuits play a very significant role in the Inverter operation. Appropriate current transformers and potential transformers are used to tap required feed back signals to initiate action on metering and protection. 3 Typical System Components a. PV MODULES: i. The PV modules must conform to the latest edition of any of the following IEC /equivalent BIS Standards for PV module design qualification and type approval: Crystalline Silicon Terrestrial PV Modules IEC / IS14286, Thin Film Terrestrial PV Modules IEC61646 / Equivalent IS (Under Dev.), Concentrator PV Modules & Assemblies IEC ii. In addition, the modules must conform to IEC61730 Part 1-requirements for construction & Part 2 requirements for testing, for safety qualification or Equivalent IS (Under Dev.) iii. PV modules to be used in a highly corrosive atmosphere (coastal areas, etc.) must qualify Salt Mist Corrosion Testing as per IEC 61701/ IS Authorized Test Centers: The PV modules must be tested and approved by one of the IEC authorized test centers. In addition a PV module qualification test certificate as per IEC standard, issued by ETDC (Electronics Test & Development Centre), Bangalore or Solar Energy Centre will also be valid. Identification and traceability: Each PV module used in any solar power project must use a RF identification tag. The following information must be mentioned in the RFID used on each module. (This can be inside or outside the laminate, but must be able to withstand harsh environmental conditions.)

10 Name of the manufacturer of PV Module Name of the Manufacturer of Solar cells Month and year of the manufacture ( separately for solar cells and module) Country of origin ( separately for solar cells and module) I-V curve for the module Wattage, Im, Vm and FF for the module Unique Serial No and Model No of the module Date and year of obtaining IEC PV module qualification certificate Name of the test lab issuing IEC certificate Other relevant information on traceability of solar cells and module as per ISO 9000 WARRANTY: PV modules used in solar power plants /systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 12 years and 80% at the end of 25 years. b. BALANCE OF SYSTEM (BOS) ITEMS/ COMPONENTS: i. Module Mounting System The mounting structure shall be designed for holding suitable number of modules in a series. The frames and leg assemblies of the array structures shall be made of mild steel hot dip galvanized of suitable sections of angle, channel or any other section confirming to IS Stainless Steel /Hot dip galvanized steel nuts and bolts will be used. The structure shall be designed to withstand all loads incl. wind etc. The mounting structure shall be designed in such a way that it will occupy minimum space without sacrificing the output from SPV modules. Specially designed Aluminum Structures may also be offered for better protection against the Corrosion over the life of the Plant. While making Civil & Mechanical design, due consideration will be given to all the dead loads, live loads, effects of wind loads, Seismic factors for the site and suitable Design margins as per prevalent Indian standard and Industry practices. The Mechanical components for the module mounting shall comply to standards to withstand wind loads of 150 Kmph and suitable design and test reports should be made available on demand. ii. Power Conditioning Unit The type of technology selected shall be suitable for the specific project location considering the PV Solar Modules selected so as to maximize the yield over the plant life. The inverter selected shall be either Distributed type or the Central type. The capacity and the number of the inverters selected shall be optimized so as to have less number of inverters however without compromising the redundancy in case of failure of the inverter. The inverters shall have

11 a Built in transformer. In case the inverter model selected is transformer-less, then the external transformers shall be provided to achieve the desired level of voltage for the evacuation system. The Offered Inverter should have internationally recognized IEC, TUV and/or UL certifications (or equivalent as approved). Manufacturer shall carry out all the tests as per the requirements of IEC, TUV and UL as applicable. Supplier shall submit all the Manufacturing Test Certificates, performance test certificates Inspection test Reports etc. in addition all the technical specification sheets, product catalogues, Installation manuals, Operation and maintenance manuals etc. in adequate numbers as finalized. General description of Inverters The DC power produced by Solar Modules is fed to inverter for conversion into AC. In a grid interactive system AC power has to be fed at 415V 3Ph 50 Hz. The output of the inverter must synchronize automatically its AC output to the exact AC voltage and frequency of the grid. The design of the inverter should be made to meet the Indian voltage and frequency conditions (the frequency band should be ±5%). The inverter continuously monitors the condition of the grid and in event of grid failure; the inverter automatically isolates the Solar Power System. The solar system is resynchronized with the grid after the restoration of grid. The inverter shall be designed so as to operate the PV system near its Maximum Power Point available, the operating point where the combined values of the current and voltage of the solar modules result in a maximum power output. The inverter should be a true sine wave inverter for a grid interactive PV system. The degree of protection of the indoor inverter panel shall be at least IP-31 and that of outdoor at least IP-55. In Addition the PCU must qualify the following IEC/equivalent BIS standards/mnre specifications/as specified below: BOS Item/ system Power Conditioning Unit/ Inverter** including MPPT and Protections (more than 100 Wp and upto 20 kwp capacity only) Applicable BIS / Equipment IEC Standard or MNRE Specifications Standard Description Standard Number Efficiency Measurements IEC 61683/ IS Environmental Testing IEC (1,2,14,30) / Equivalent BIS Standard

12 Charge Controller / MPPT Units Environmental Testing IEC (1,2,14,30) / Equivalent BIS Standard ** In case if the Charge controller is in-built in the inverter, no separate IEC test is required and must additionally conform to the relevant national/international Electrical Safety Standards wherever applicable c. POWER QUALITY REQUIREMENTS The Total Harmonic distortion and ripple content on AC and DC side must not exceed 3 % the provision to measure harmonics should be inbuilt feature of the inverter. Voltage unbalance at the inverter output will be limited to one percent (1 %) The power factor maintained by the inverter should be close to unity The nominal steady state electrical characteristics of the system are as follows: a. Three phase alternating current at 50 Hz plus or minus 0.5 Hz b. Nominal voltage of 110 kv with +10 % to -12 % variations The project shall be designed and capable of being synchronized and operated within a frequency range of 48.5 to 51.5 Hz at Grid Voltages. The Operation of the project outside the nominal voltage and frequency specified above will result in reduction of power output consistent with generator capability curves. While designing the system EPC contractor shall comply with the provisions of the applicable law including, in particular, state grid code as amended from time to time regarding the erection; testing; commissioning; operation and maintenance parameters of the Solar Power Project. Notwithstanding anything in the above, the Inverters should be equipped to synchronize with the Grid under the existing and possible future requirements as per the Grid Codes that may be in effect. d. CABLES, SWITCHES, CIRCUIT BREAKERS, CONNECTORS AND JUNCTION BOXES i. Cables: The cables deployed will be robust and resist high mechanical load and tension. Cable should have High temperature resistance and weather proofing characteristics to ensure long life. The connectors should have high current carrying capacity. All the cables and connectors shall have IEC, UL, TUV or equivalent approval and shall be designed to have excellent UV Resistance. The cables should have Halogen free and flame retardant characteristic. All the cables shall be suitably designed and sized to carry DC and AC currents with the low voltage drops. The cables supplied shall have a proven track record for the use in PV Solar Plants. All cables shall be supplied conforming to IEC 60227/ IS 694 & IEC60502/ IS 1554 Voltage rating: 1,100V AC, 1,500V DC.

13 ii. Switches, Circuit Breakers, Connectors All Switches, Circuit Breakers, Connectors shall be supplied conforming to IEC part I,II, III / IS Part I,II,III/ EN iii. Junction Boxes All Junction Boxes shall be supplied conforming to IP 54(for outdoor)/ IP 21(for indoor) as per IEC 529. e. TRANSFORMER Step-up Transformers will be used to step-up the PCU output voltage to exportable power voltage. In case the transformer is an integral part of the Inverter (PCU), then a separate transformer shall not be required. f. SWITCHYARD EQUIPMENT STRUCTURES The structures will be made up of hot-dip galvanized steel and designed to withstand forces during normal conditions (viz. wind loads & dead load of switchyard components) and abnormal conditions (viz. short circuit, earthquake, etc.). g. EARTHING i. The PV module structure components shall be electrically interconnected and shall be grounded. ii. Earthing shall be done in accordance with IS , provided that earthing conductors shall have a minimum size of 6.0 mm² copper, 10 mm² aluminium or 70 mm² hot dip galvanised steel. Unprotected aluminium or copper-clad aluminium conductors shall not be used for final underground connections to earth electrodes. iii. A minimum of two separate dedicated and interconnected earth electrodes must be used for the earthing of the solar PV system support structure with a total earth resistance not exceeding 5 ohm. iv. The earth electrodes shall have a precast concrete enclosure with a removable lid for inspection and maintenance. The entire earthing system shall comprise non-corrosive components. h. SURGE PROTECTION i. Surge protection shall be provided on the DC side and the AC side of the solar system. ii. The DC surge protection devices (SPDs) shall be installed in the DC distribution box adjacent to the solar grid inverter. iii. The AC SPDs shall be installed in the AC distribution box adjacent to the solar grid inverter. iv. The SPDs earthing terminal shall be connected to earth through the above mentioned dedicated earthing system. The SPDs shall be of type 2 as per IEC

14 i. POWER EVACUATION SYSTEM The power from the PCUs/Transformers is collected in a collecting station (Pooling Substation inside the SPV Plant Boundary) and the high voltage power is routed through the circuit breakers to the Transmission line and be eventually connected to the grid. It is important that the SPV power plant is designed to operate satisfactorily in parallel with the grid within permissible limits of voltage and frequency fluctuation conditions, so as to export the maximum possible units to the grid. The proposed PCU shall have the capability for monitoring the grid parameters (like voltage, frequency and harmonics) and getting the SPV Power Plant output synchronized with the grid on a real time basis. All the associated equipments for the transmission line and the extension of bay in the receiving Grid substation are covered under the evacuation system. j. CAUTION SIGNS The standard caution and danger boards or labels as per Indian Electricity Rules, the AC distribution box near the solar grid inverter and the building distribution board to which the AC output of the solar PV system is connected shall be provided with a noncorrosive caution label. k. METERING i. For the purpose of net metering, the meter alongwith its accessories should be installed as per the CEA guidelines/hperc guidelines/ HPSEBL guidelines along with necessary protection devices. The meter and its accessories will have to be provided by the firm after getting them tested from the HPSEBL approved test centers. Cost of the meter/accessories and its testing will have to borne by the beneficiary only. ii. It is mandatory that the Solar Rooftop PV system shall be connected to the Grid as per the guidelines of HPSEBL along with necessary protection devices. m. DOCUMENTATION The Installer shall supply the following documentation: System description with working principles. System single line diagram. Solar PV array lay-out. Routing diagram of cables and wires. Data sheets and user manuals of the solar PV panels and the solar grid inverter. A system operation and maintenance manual. Name, address, mobile number and address of the service centre to be contacted in case of failure or complaint. Warranty cards.

15 Maintenance registers. n. QUALITY AND WORKMANSHIP Solar PV modules are designed to last 25 years or more. It is therefore essential that all system components and parts, including the mounting structures, cables, junction boxes, distribution boxes and other parts also have a life cycle of at least 25 years. Therefore all works shall be undertaken with the highest levels of quality and workmanship. During inspection HIMURJA and its representatives will pay special attention to neatness of work execution and conformity with quality and safety norms. Non-compliant works will have to be redone at the cost of the Installer. o. WARRANTY The mechanical structures, electrical works including power conditioners/inverters/charge controllers/maximum power point tracker units/distribution boards/digital meters/switch gear/storage batteries, etc. and over all workmanship of the SPV power plants/ systems must be warranted against any manufacturing/ design/ installation defects for a minimum period of 5 years. p. Connection of Bidirectional meter The bidirectional meters will be connected to HPSEBL Grid on following voltages: i) Upto 5 kwp SPV Power Plant = Single Phase line ii) Above 5kWp to15 kwp SPV Power Plant = Three Phase line iii) Above 15kWp to 1 MWp SPV Power Plant = HT/EHT Line Firms will select the PCU and Bidirectional meters accordingly.

16 Annexure I BIDDER FORM 1. Bid No: 2. Name of the work: 3. Last date and time of submission of the documents: 4. Amount of Earnest Money Deposit: DD and Date 5. Date and time of opening of the Bid: 6. Place of opening of the bid: 7. Name and status of firm/company individual to whom the bid document is issued : 8 Validity of Bid 9. Name of the authorized representative to Sign the Bid (Signature of Bidder) with designation All the columns must be filled by the Bidder.

17 Annexure II GENERAL PARTICULARS OF THE BIDDER 1. Name of Bidder: 2 Address for correspondence: 3. Telephone No. and Fax No. 4. address: 5 Name and Designation of the Authorized Representative of the bidder to whom all the references shall be made: 6 Amount and reference of E.M.D. Deposited (Drawn on Bank & D.D. No.& date) 7 Financial capability of the contractor/ Firm for carrying out the work: 8 Has the firm ever been debarred by any Govt. Deptt/Agency/organization for undertaking any work: 9 Details of offer (Mention No of pages): 10. Reference of any other information attached by the Bidder: 11. Authorized representative for any correspondence 12. Whether service center for after sales service set up in the state, give address (Signature of Bidder) with designation

18 Annexure III DECLARATION BY THE BIDDER I/We (herein after referred to as the bidder) being desirous of bidding for the design, manufacture, supply, erection, testing, installation and commissioning of SPV power plants 1 kwp to 500 kwp in different parts in H.P including warranty period of 5 years as shown in scope of bid specification. We have fully understood the nature of the work and carefully noted all the terms and conditions, specifications etc. as mentioned in the bid documents, hereby declare that:- 1. The bidder is fully aware of all the requirements of the bid documents and agrees with all the provisions of the bid documents. 2. The bidder is capable of executing and completing the work as required in the bid. 3. The bidder accepts all risks and responsibilities directly or indirectly connected with the performance of the bid. 4. The bidder is financially solvent and sound to execute the bid. 5. The bidder is sufficiently experienced and competent to perform the contract to the satisfaction of HIMURJA. 6. The information and statements submitted with the bid are true. 7. The bidder has not been debarred from similar type of work by any Govt Dept./Agency/Organization. 8. This offer will remain valid for acceptance for 12 (Twelve) months from the date of finalization of the bid and can be extenteded further. 9. The bidder gives the assurance to execute the bided work as per the specifications, terms and conditions and in exact configuration of the sample submitted on award of the work. (Signature of Bidder) with designation

19 Annexure IV SCHEDULE OF PAST SUPPLIES OF LAST THREE YEARS S No Description Supply order No. and date Name of Agency Date of Supply/ completion as per order Actual date of supply/ commissioning on (Signature of Bidder) with designation Note:- Performance certificate from the concerned utilities along with their communication address, e- mail and FAX No. is required for authentication of certificates.

20 Annexure V Guaranteed Technical Parameters S.No. ITEM PARTICULARS 1 SOLAR PHOTOVOLTAIC MODULES 1.1 Name of Manufacturer 1.2 SIZE (dimension) 1.3 Type 1.4 P max 1.5 IEC certificate Date of issue Agency Validity Enclose a IEC certificate 1.12 Warranty of modules 2 PCU 2.1 TYPE Name of Manufacturer 2.9 Protection features as per Net Metering guidelines of H.P. 3. Solar Meter 3.1 Name of manufacturer 4 Bidirectional Meter 4.1 Name of manufacturer Signature of the Bidder

21 Annexure-VI UNDERTAKING TO BE FURNISHED BY BIDDERS We, M/S with Registered office at undertake to ensure generation of electrical energy from the Solar Power Plant of 1 kwp to 500 kwp to be installed by us as per the details / technical specifications given in Bid document. Authorized Signatory Name of the Company with stamp

22 Financial Bids Name of Work: Rate contract for Design, manufacture, supply, erection, testing and commissioning including warranty, operation & maintenance for 5 years of Grid Interactive Rooftop Solar Power Plants of capacities from 1 kwp to 500 kwp in the State of Himachal Pradesh. We give our unconditional financial rates including all taxes and duties in response of this tender Document issued by HIMURJA. The rates are FOR destination at the sites of the beneficiaries including transportation and insurance etc. 1. For RTS Plants S.No Particulars of Work 1 Up to 10 kwp For 2.5 MW plants at Govt. Building in Shimla city Rate per KW in INR For 10.0 MW plants at Domestic / Institution (registered under society/trust act) / Social Sector / Govt. Building in the State 2 Above 10 kwp up to 50 kwp 3 Above 50 kwp up to 100 kwp 4 Above 100 kwp up to 300 kwp 5 Above 300 kwp up to 500 kwp (Note: The above rates are inclusive of all the taxes, duties etc.) Signature Name Designation with Seal

23 Financial Bids 2. For Net Metering Purpose S. Description No. 1. Solar Meter Rate a) For L.T. (Size wise Rates) b) For H.T (Size wise Rates) 2 Bi-directional meter a) For L.T. (Size wise Rates) b) For H.T. (Size wise Rates) 3. C.T. (Current Transformer) a) For L.T. (Size wise Rates) a) For H.T (Size wise Rates) 4. P.T. (Potential Transformer) a) For L.T. (Size wise Rates) a) For H.T. (Size wise Rates) These rates are for evaluation purpose only and will not be as part of the evaluation for the financial bids. These rates are required for the GCRTS plants to be installed in the Govt buildings. (Note: The above rates are inclusive of all the taxes, duties etc.) Signature Name Designation with Seal

HIMURJA. H.P. Govt. Energy Development Agency. 8-A,SDA Complex, Kasumpti, Shimla Himachal Pradesh, INDIA. Telephone No:

HIMURJA. H.P. Govt. Energy Development Agency. 8-A,SDA Complex, Kasumpti, Shimla Himachal Pradesh, INDIA. Telephone No: Document No. HIMURJA (F-7) / SPV Plant / RTS / 2017-18 Rate Contract for the installation of Grid Connected Rooftop Solar Power Plants under empanelment scheme for the Design, manufacture, supply, erection,

More information

INVITATION FOR QUOTATION. TEQIP-III/2018/uceo/Shopping/48

INVITATION FOR QUOTATION. TEQIP-III/2018/uceo/Shopping/48 INVITATION FOR QUOTATION TEQIP-III/2018/uceo/Shopping/48 29-Dec-2018 To, Sub: Invitation for Quotations for supply of Goods Dear Sir, 1. You are invited to submit your most competitive quotation for the

More information

Generalised Technical Specifications for Grid Tie Solar Power plants

Generalised Technical Specifications for Grid Tie Solar Power plants Generalised Technical Specifications for Grid Tie Solar Power plants The Grid tie Solar Power Plants without battery may be installed for any office buildings. As the office buildings have day time energy

More information

BANGALORE ELECTRICITY SUPPLY COMPANY LIMITED

BANGALORE ELECTRICITY SUPPLY COMPANY LIMITED GUIDELINES FOR EMPANELMENT OF GRID TIED INVERTER MANUFACTURERS FOR IMPLEMENTATION OF SRTPV PROGRAM IN BESCOM. I. NEW EMPANELMENT 1. The grid tied inverter manufacturer shall register their application

More information

Solar Energy Corporation of India Limited New Delhi Expression of Interest for Setting up of Solar PV Manufacturing Capacities in India

Solar Energy Corporation of India Limited New Delhi Expression of Interest for Setting up of Solar PV Manufacturing Capacities in India SECI/SD/EoI/20000 MW Mfg./I/2017 18.12.2017 Expression of Interest for Setting up of Solar PV Manufacturing Capacities in India 1. Objective of EOI: SECI intends to invite Expression of Interest from the

More information

NOTICE INVITING TENDER

NOTICE INVITING TENDER TENDER FOR SUPPLY, INSTALLATION AND COMMISSIONING OF 30kWp On Grid SOLAR POWER PLANT AT FACC/CHRD/LAKE HALL, BIDHAN CHANDRA KRISHI VISWAVIDYALAYA (BCKV), KALYAN, DIST NADIA, WEST BENGAL, INDIA, PIN 741235

More information

SUBSIDY SCHEME FOR GRID CONNCTED AND OFF GRID SOLAR SYSTEMS AT IOCL PETROL PUMPS

SUBSIDY SCHEME FOR GRID CONNCTED AND OFF GRID SOLAR SYSTEMS AT IOCL PETROL PUMPS SUBSIDY SCHEME FOR GRID CONNCTED AND OFF GRID SOLAR SYSTEMS AT IOCL PETROL PUMPS FIRSTGREEN CONSULTING PVT LTD MA, 74, DLF Phase III Gurgaon 122002 info@firstgreen.co +91-124-6450224 1. ABOUT THE PROGRAM

More information

Application for release of capital subsidy on installation of Grid Connected Solar Power Plant

Application for release of capital subsidy on installation of Grid Connected Solar Power Plant Chandigarh Renewal Energy, Science & Technology Promotion Society (CREST) Under the Aegis of Department of Science & Technology, Chandigarh Administration), Paryavaran Bhawan, First Floor, Sec-19B, Madhya

More information

SUBSIDY SCHEME FOR GRID CONNCTED SOLAR ROOFTOP POJECT IN ASSAM UNDER THE 14 MW RESCO AND CAPEX MODEL

SUBSIDY SCHEME FOR GRID CONNCTED SOLAR ROOFTOP POJECT IN ASSAM UNDER THE 14 MW RESCO AND CAPEX MODEL SUBSIDY SCHEME FOR GRID CONNCTED SOLAR ROOFTOP POJECT IN ASSAM UNDER THE 14 MW RESCO AND CAPEX MODEL Submitted By: FIRSTGREEN CONSULTING PVT LTD MA, 74, DLF Phase III Gurgaon 122002 info@firstgreen.co

More information

PINANK ENERGY An ISO 9001: 2015 (QMS) Certified Company Channel Partner: Ministry of New and Renewable Energy, Govt of India

PINANK ENERGY An ISO 9001: 2015 (QMS) Certified Company Channel Partner: Ministry of New and Renewable Energy, Govt of India 1 P a g e PINANK ENERGY An ISO 9001: 2015 (QMS) Certified Company Channel Partner: Ministry of New and Renewable Energy, Govt of India PROPOSAL FOR: ROOF-TOP SOLAR PV PLANT Pinank Engineering and services

More information

Policy for Net-Metering based Renewable Energy Applications, Madhya Pradesh, DRAFT

Policy for Net-Metering based Renewable Energy Applications, Madhya Pradesh, DRAFT Policy for Net-Metering based Renewable Energy Applications, Madhya Pradesh, 2015- DRAFT 1. PREAMBLE 1.1 To harness the potential of renewable energy resources in the state, Government of Madhya Pradesh

More information

Supply of Batteries

Supply of Batteries Supply of Batteries 207-8 SUPPLY OF BATTERIES OF VARIOUS RATINGS E-PROCUREMENT (REVERSE AUCTION) NIT No: 07/ 207-8 Name of the work Supply of Batteries to our Branches / Offices /ATM Completion Time EMD

More information

Supply, Installation and Commissioning of 1 No 50 Watt LED. based SPV SLS at Nadia District Library, Krishna Nagar, Nadia.

Supply, Installation and Commissioning of 1 No 50 Watt LED. based SPV SLS at Nadia District Library, Krishna Nagar, Nadia. Supply, Installation and Commissioning of 1 No 50 Watt LED based SPV SLS at Nadia District Library, Krishna Nagar, Nadia. TENDER DOCUMENT. (A Govt. of West Bengal Company) Bikalpa Shakti Bhavan, Plot J1/10,

More information

Ministry of New and Renewable Energy (Jawaharlal Nehru National Solar Mission) Form B for Project Proposals for

Ministry of New and Renewable Energy (Jawaharlal Nehru National Solar Mission) Form B for Project Proposals for Form B Ministry of New and Renewable Energy (Jawaharlal Nehru National Solar Mission) Form B for Project Proposals for Grid Connected Rooftop and Small SPV Power Plants (For the project above 5 kwp & upto

More information

TECHNICAL SPECIFICATION FOR 11 KV AUTOMATIC CAPACITOR SWITCH

TECHNICAL SPECIFICATION FOR 11 KV AUTOMATIC CAPACITOR SWITCH TECHNICAL SPECIFICATION FOR 11 KV AUTOMATIC CAPACITOR SWITCH MAHARASHTRA STATE ELECTRICITY DISTRIBUTION COMPANY LTD. PAGE 1 OF 7 TECHNICAL SPECIFICATION FOR 11 KV AUTOMATIC CAPACITOR SWITCH 1.0 SCOPE:

More information

Roof Top Solar Power Net Metering Solution. Guidelines for implementation of Net Metering for Roof Top Solar Power System

Roof Top Solar Power Net Metering Solution. Guidelines for implementation of Net Metering for Roof Top Solar Power System Roof Top Solar Power Net Metering Solution Guidelines for implementation of Net Metering for Roof Top Solar Power System 1. Net Metering arrangement is permitted for 3 Phase connections only. The interconnection

More information

Sun-Grid Electric Private Limited. Presented by:

Sun-Grid Electric Private Limited. Presented by: SUN-GRID ELECTRIC PVT LTD (All Types of Solar and Electric Projects) For Residential & Commercial Buildings Offices Industries Hospitals Educational Institutions Hotels & Resorts Presented by: Sun-Grid

More information

INTERCONNECTION STANDARDS FOR CUSTOMER-OWNED GENERATING FACILITIES 25 kw OR LESS PUBLIC UTILITY DISTRICT NO. 1 OF CHELAN COUNTY

INTERCONNECTION STANDARDS FOR CUSTOMER-OWNED GENERATING FACILITIES 25 kw OR LESS PUBLIC UTILITY DISTRICT NO. 1 OF CHELAN COUNTY INTERCONNECTION STANDARDS FOR CUSTOMER-OWNED GENERATING FACILITIES 25 kw OR LESS PUBLIC UTILITY DISTRICT NO. 1 OF CHELAN COUNTY Table of Contents Chapter 1. Purpose and scope. Pg 3 Chapter 2. Application

More information

Joint Inspection Report

Joint Inspection Report Joint Inspection Report CERTIFICATE (To be furnished by SNA/PSU/Channel Partner) This is to certify that Shri... (Name & designation) of.... (Organization) visited the. Nos. of plant sites on (date). and

More information

Net +Plus Connection Code

Net +Plus Connection Code Net +Plus Connection Code LANKA ELECTRICITY COMPANY (PRIVATE) LIMITED 1.0 BACKGROUND The existing Net Metering Concept launched in the year 2010 noticed an exponential growth in the recent year and at

More information

INDIAN INSTITUTE OF TECHNOLOGY, KANPUR DEPARTMENT OF ELECTRICAL ENGINEERING

INDIAN INSTITUTE OF TECHNOLOGY, KANPUR DEPARTMENT OF ELECTRICAL ENGINEERING To, Ref No: IIT/ EE/SMART CITY/INVERTER AND BATTERY SET/2015/02 INVITATION FOR QUOTATIONS FOR SUPPLY OF THE FOLLOWING ITEMS REQUIRED FOR SMART CITY PILOT PROJECT AT IIT KANPUR S.No. Brief Description of

More information

SPECIFICATIONS OF WHITELED (W-LED) BASED SOLAR LANTERN

SPECIFICATIONS OF WHITELED (W-LED) BASED SOLAR LANTERN SPECIFICATIONS OF WHITELED (W-LED) BASED SOLAR LANTERN White Light Emitting Diode (W-LED) is a solid state device which emits light when an electric current passes through it. A Solar lantern is a lighting

More information

Policy for Net-Metering based Renewable Energy Applications, Madhya Pradesh, DRAFT

Policy for Net-Metering based Renewable Energy Applications, Madhya Pradesh, DRAFT Policy for Net-Metering based Renewable Energy Applications, Madhya Pradesh, 2015- DRAFT 1. PREAMBLE 1.1 To harness the potential of renewable energy resources in the state, Government of Madhya Pradesh

More information

DETAILED NOTICE INVITING TENDER WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED. (A Govt of West Bengal Enterprise)

DETAILED NOTICE INVITING TENDER WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED. (A Govt of West Bengal Enterprise) DETAILED NOTICE INVITING TENDER WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED (A Govt of West Bengal Enterprise) CHIEF ENGINEER (PROCUREMENT), VIDYUT BHAVAN NOTICE INVITING TENDERS For CONSTRUCTION

More information

EXTRA ORDINARY 16 AASHAADHA, 1937(S) BIHAR ELECTRICITY REGULATORY COMMISSION

EXTRA ORDINARY 16 AASHAADHA, 1937(S) BIHAR ELECTRICITY REGULATORY COMMISSION REGISTERED NO. PT.-40 The B Bihar Gazett te EXTRA ORDINARY PUBLISHED BY AUTHORITY 16 AASHAADHA, 1937(S) (NO.PATNA 737) PATNA, TUESDAY, 7 TH JULY 2015 BIHAR ELECTRICITY REGULATORY COMMISSION NOTIFICATION

More information

Bihar Electricity Regulatory Commission Vidyut Bhawan, J.L.Nehru Marg, Patna

Bihar Electricity Regulatory Commission Vidyut Bhawan, J.L.Nehru Marg, Patna Bihar Electricity Regulatory Commission Vidyut Bhawan, J.L.Nehru Marg, Patna 800 021 ------------------------------------------------------------------------------------------------------------- ROOFTOP

More information

KERALA STATE ELECTRICITY REGULATORY COMMISSION. NOTIFICATION Dated, Thiruvananthapuram 6 th August,2007

KERALA STATE ELECTRICITY REGULATORY COMMISSION. NOTIFICATION Dated, Thiruvananthapuram 6 th August,2007 KERALA STATE ELECTRICITY REGULATORY COMMISSION NOTIFICATION No.1/1/KSERC-2006/ Dated, Thiruvananthapuram 6 th August,2007 KSERC (Supply of Power from Captive Generating Plants to Distribution Licensees)

More information

UP Electricity Regulatory Commission Vidyut Niyamak Bhawan, Vibhuti Khand, Gomti Nagar, Lucknow. Public Notice

UP Electricity Regulatory Commission Vidyut Niyamak Bhawan, Vibhuti Khand, Gomti Nagar, Lucknow. Public Notice UP Electricity Regulatory Commission Vidyut Niyamak Bhawan, Vibhuti Khand, Gomti Nagar, Lucknow No.UPERC/ Secy/JD(G)/2018/ dated : 20 th August, 2018 Public Notice The Commission is in process of reviewing

More information

THE ORIENTAL INSURANCE CO.LTD. REGIONAL OFFICE: IDA Building 4 th Floor, 7,Race Course Road, Indore (M.P.) REQUIREMENT

THE ORIENTAL INSURANCE CO.LTD. REGIONAL OFFICE: IDA Building 4 th Floor, 7,Race Course Road, Indore (M.P.) REQUIREMENT THE ORIENTAL INSURANCE CO.LTD. REGIONAL OFFICE: IDA Building 4 th Floor, 7,Race Course Road, Indore -452003 (M.P.) ANNEXURE -III REQUIREMENT OICL intends to procure reputed brand Exide or Amara Raja or

More information

Tender Document for. NAME OF THE SUPPLIER / MANUFACTURER: NREDCAP Registration No: /

Tender Document for. NAME OF THE SUPPLIER / MANUFACTURER: NREDCAP Registration No: / Tender Document for Supply of around 50,000 Nos of Solar Lanterns to the P.O, ITDA's of West Godavari, East Godavari, Visakhapatnam, Vizianagaram and Srikakulam Districts for distribution to all S.T students

More information

IDCOL Technical Standard for Solar Irrigation Pump (SIP) Under TR/KABITA Program

IDCOL Technical Standard for Solar Irrigation Pump (SIP) Under TR/KABITA Program IDCOL Technical Standard for Solar Irrigation Pump (SIP) Under TR/KABITA Program Details of approved packages Program Daily water output (Lt/day) Maximum TDH (m) 100,000 15 50,000 30 TR/KABITA 200,000

More information

IDCOL Technical Standard for Solar Irrigation Pump (SIP) Under Ownership Model

IDCOL Technical Standard for Solar Irrigation Pump (SIP) Under Ownership Model IDCOL Technical Standard for Solar Irrigation Pump (SIP) Under Ownership Model Configuration of approved packages: Program Daily water output (Lt/day) 100,000 Maximum TDH (m) Minimum PV capacity (kwp)

More information

Louisville Gas and Electric Company

Louisville Gas and Electric Company P.S.C. Electric No. 11, Original Sheet No. 57 APPLICABLE In all territory served. AVAILABILITY OF SERVICE Available to any customer-generator who owns and operates a generating facility located on Customer

More information

TENDER. Enq. No. IIITMK/ 0648/18 Date: 07/09/18 Due on:17/09/20183pm

TENDER. Enq. No. IIITMK/ 0648/18 Date: 07/09/18 Due on:17/09/20183pm TENDER Enq. No. IIITMK/ 0648/18 Date: 07/09/18 Due on:17/09/20183pm On behalf of INDIAN INSTITUTE OF INFORMATION TECHNOLOGY & MANAGEMENT KERALA (IIITMK), the Registrar invites offers for supply and laying

More information

100kW GROUND MOUNTED SOLAR PHOTOVOLTIC POWER PLANT DETAILED PROJECT REPORT AERO SPACE MATERIALS PVT LTD

100kW GROUND MOUNTED SOLAR PHOTOVOLTIC POWER PLANT DETAILED PROJECT REPORT AERO SPACE MATERIALS PVT LTD EXECUTIVE SUMMARY 100kW GROUND MOUNTED SOLAR PHOTOVOLTIC POWER PLANT 1. Location i) State : TAMIL NADU, ii) Locality : KOVILPALAYAM, POLLACHI iii) Latitude : 10 45 16.22 N iv) Longitude : 77 01 15.27 E

More information

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB) 020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB) CEYLON ELECTRICITY BOARD SRI LANKA Telephone: +94 11 232 0953 Fax: +94 11 232 3935 CONTENTS Page 1.0 Scope 3 2.0 System Parameters 3 3.0 Service

More information

ANNEXURE-I CHECK LIST FOR APPLICATION FORM

ANNEXURE-I CHECK LIST FOR APPLICATION FORM ANNEXURE-I CHECK LIST FOR APPLICATION FORM S.No. DOCUMENTS REQUIRED SUBMITTED 1 Application Form must be signed by Registered Consumer on each page with stamp 2 Occupancy Proof along with roof rights (Registered

More information

ODISHA ELECTRICITY REGULATORY COMMISSION UNIT VIII, BHUBANESWAR

ODISHA ELECTRICITY REGULATORY COMMISSION UNIT VIII, BHUBANESWAR ODISHA ELECTRICITY REGULATORY COMMISSION UNIT VIII, BHUBANESWAR 751012 ORDER No. OERC-Engg. 02/2010/(Vol-III)/1597(A) Dated : 26.11.2014 ON NET METERING/BI-DIRECTIONAL METERING & THEIR CONNECTIVITY WITH

More information

GRID CONNECTED 400kWp SOLAR ROOF TOP POWER PLANT NET METERING AT KARNATAKA STATE CRICKET ASSOCIATION M. CHINNASWAMY STADIUM, BENGALURU

GRID CONNECTED 400kWp SOLAR ROOF TOP POWER PLANT NET METERING AT KARNATAKA STATE CRICKET ASSOCIATION M. CHINNASWAMY STADIUM, BENGALURU MGIRED Journal Volume 2(1) : 125-128 ISSN 2393-9605 GRID CONNECTED 400kWp SOLAR ROOF TOP POWER PLANT NET METERING AT KARNATAKA STATE CRICKET ASSOCIATION M. CHINNASWAMY STADIUM, BENGALURU Punati Sridhar,

More information

Tender documents for supply, erection & commissioning of Plante Type Battery to 2x210 MW IB Thermal Power Station.

Tender documents for supply, erection & commissioning of Plante Type Battery to 2x210 MW IB Thermal Power Station. ORISSA POWER GENERATION CORPORATION LIMITED IB THERMAL POWER STATION AT/P.O: BANHARPALI, DIST: JHARSUGUDA, PIN: 768234 (ORISSA), INDIA GRAM: IB THERMAL, TEL: 06645-222209/222210, FAX: 06645-222209/54/30

More information

Noble County Rural Electric Membership Corporation

Noble County Rural Electric Membership Corporation Albion, Indiana Page 1 of 5 SCHEDULE NB-1 RESIDENTIAL NET BILLING I. AVAILABILITY This Net Billing Rate is available to any residential member in good standing of Noble REMC (Noble) who owns and operates

More information

City of Banning Electric Utility - Residential Self Generating Facility Program (Photovoltaic Systems <48kW)

City of Banning Electric Utility - Residential Self Generating Facility Program (Photovoltaic Systems <48kW) City of Banning Electric Utility - Residential Self Generating Facility Program (Photovoltaic Systems

More information

REVISED 8/1/2018 SOLAR PHOTOVOLTAIC DISTRIBUTED GENERATION CUSTOMER GUIDELINES, APPLICATION & WGC INTERCONNECTION AGREEMENT

REVISED 8/1/2018 SOLAR PHOTOVOLTAIC DISTRIBUTED GENERATION CUSTOMER GUIDELINES, APPLICATION & WGC INTERCONNECTION AGREEMENT REVISED 8/1/2018 SOLAR PHOTOVOLTAIC DISTRIBUTED GENERATION CUSTOMER GUIDELINES, APPLICATION & WGC INTERCONNECTION AGREEMENT INTRODUCTION Lathrop Irrigation District has created a policy to allow safe connection

More information

DRAFT. Guidelines on Power quality & safety issues in usage of roof-top solar pv system CENTRAL ELECTRICITY AUTHORITY

DRAFT. Guidelines on Power quality & safety issues in usage of roof-top solar pv system CENTRAL ELECTRICITY AUTHORITY DRAFT Guidelines on Power quality & safety issues in usage of roof-top solar pv system CENTRAL ELECTRICITY AUTHORITY 2018 1. INTRODUCTION Solar energy has become the most popular renewable energy source

More information

INVITATION FOR QUOTATION. TEQIP-II/2015/GJ1G02/Shopping/M-EE-09

INVITATION FOR QUOTATION. TEQIP-II/2015/GJ1G02/Shopping/M-EE-09 INVITATION FOR QUOTATION TEQIP-II/2015/GJ1G02/Shopping/M-EE-09 02-Dec-2015 Sub: Invitation for Quotations for supply of Goods Dear Sir, 1. You are invited to submit your most competitive quotation for

More information

IDCOL Technical Standard for Solar Irrigation Pump (SIP) Projects

IDCOL Technical Standard for Solar Irrigation Pump (SIP) Projects P a g e 1 IDCOL Technical Standard for Solar Irrigation Pump (SIP) Projects Scope of standardization: Equipment standardization : 1. Pump & Motor 2. PV panels 3. Controller Civil construction standardization:

More information

INVITATION FOR QUOTATION. TEQIP-III/2018/gcej/Shopping/50

INVITATION FOR QUOTATION. TEQIP-III/2018/gcej/Shopping/50 INVITATION FOR QUOTATION TEQIP-III/2018/gcej/Shopping/50 15-Sep-2018 To, Sub: Invitation for Quotations for supply of Goods Dear Sir, 1. You are invited to submit your most competitive quotation for the

More information

Northeastern Rural Electric Membership Corporation Schedule DG-2 Columbia City, Indiana Page 1 of 5

Northeastern Rural Electric Membership Corporation Schedule DG-2 Columbia City, Indiana Page 1 of 5 Columbia City, Indiana Page 1 of 5 SCHEDULE DG-2 LARGE POWER DISTRIBUTED GENERATION I. AVAILABILITY This Distributed Generation Rate is available to any member in good standing of Northeastern REMC (Northeastern)

More information

RATE 765 RENEWABLE FEED-IN TARIFF

RATE 765 RENEWABLE FEED-IN TARIFF NORTHERN INDIANA PUBLIC SERVICE COMPANY Original Sheet No. 104 TO WHOM AVAILABLE Sheet No. 1 of 12 This Rate Schedule is a voluntary offer available to any Customer that operates within the Company s service

More information

A member-consumer with a QF facility shall not participate in the Cooperative s electric heat rate program.

A member-consumer with a QF facility shall not participate in the Cooperative s electric heat rate program. Electric Tariff _2nd Revised Sheet No. 72 Filed with Iowa Utilities Board Cancels _1st Sheet No. _72 Cooperative is a member of Central Iowa Power Cooperative (CIPCO), a generation and transmission cooperative

More information

SSC-JE STAFF SELECTION COMMISSION ELECTRICAL ENGINEERING STUDY MATERIAL. Estimation and Costing & Utilization of Electrical Energy

SSC-JE STAFF SELECTION COMMISSION ELECTRICAL ENGINEERING STUDY MATERIAL. Estimation and Costing & Utilization of Electrical Energy 1 SSC-JE STAFF SELECTION COMMISSION ELECTRICAL ENGINEERING STUDY MATERIAL Estimation and Costing & Utilization of Electrical Energy Estimation and Costing & Utilization of electrical Energy Estimation

More information

TECHNICAL SPECIFICATIONS OF 2 KVA POWER CONDITIONING UNIT

TECHNICAL SPECIFICATIONS OF 2 KVA POWER CONDITIONING UNIT TECHNICAL SPECIFICATIONS OF 2 KVA POWER CONDITIONING UNIT 1.0 PURPOSE: 1. To charge the battery bank through Solar PV source and AC supply. 2. To invert and produce utility quality sine wave. 3. Inverters

More information

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS 013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS FOR OVERHEAD NETWOKS CEYLON ELECTRICITY BOARD SRI LANKA Specification for MOULDED CASE CIRCUIT BREAKERS FOR OVERHEAD NETWOKS CEB Specification

More information

Consumer Guidelines for Electric Power Generator Installation and Interconnection

Consumer Guidelines for Electric Power Generator Installation and Interconnection Consumer Guidelines for Electric Power Generator Installation and Interconnection Habersham EMC seeks to provide its members and patrons with the best electric service possible, and at the lowest cost

More information

TECHNICAL BID T 3627

TECHNICAL BID T 3627 TECHNICAL BID T 3627 Supply of Mechanical Measuring Instruments for TMD-II OF UKAI TPS. Due on At 3.30 P.M. (if Possible) EMD paid YES / NO EMD D. D. No. Date : OR SSI / NSIC Certification Number : Duly

More information

JEA Distributed Generation Policy Effective April 1, 2018

JEA Distributed Generation Policy Effective April 1, 2018 Summary This JEA Distributed Generation Policy is intended to facilitate generation from customer-owned renewable and non-renewable energy generation systems interconnecting to the JEA electric grid. The

More information

Supply & Installation of Latest Version NX CAD Academic Software (NX9)

Supply & Installation of Latest Version NX CAD Academic Software (NX9) ISO 9001:2008 TENDER FOR Supply & Installation of Latest Version NX CAD Academic Software (NX9) Tender Inquiry No. NSIC/NTSC/CAD/CAM/CNC/UG- NX Software/051/15-16 NSIC- Technical Services Centre (A Government

More information

GUIDE FOR MICROGENERATION INTERCONNECTION TO CITY OF MEDICINE HAT ELECTRIC DISTRIBUTION SYSTEM

GUIDE FOR MICROGENERATION INTERCONNECTION TO CITY OF MEDICINE HAT ELECTRIC DISTRIBUTION SYSTEM GUIDE FOR MICROGENERATION INTERCONNECTION TO CITY OF MEDICINE HAT ELECTRIC DISTRIBUTION SYSTEM Page 1 of 19 Table of Contents 1.0 SCOPE...4 2.0 PURPOSE...4 3.0 LIMITATIONS...5 4.0 GENERAL INTERCONNECTION

More information

POWER PURCHASE AGREEMENT FOR ROOFTOP SOLAR PV PLANTS WITH NET METERING ARRANGEMENT

POWER PURCHASE AGREEMENT FOR ROOFTOP SOLAR PV PLANTS WITH NET METERING ARRANGEMENT POWER PURCHASE AGREEMENT FOR ROOFTOP SOLAR PV PLANTS WITH NET METERING ARRANGEMENT This Power Purchase agreement is entered into at (place).. on this. day of between Manipur State Power Distribution Company

More information

SPICES BOARD (Ministry of Commerce & Industry, Govt. of India) Palarivattom.P.O. N H By Pass Kochi

SPICES BOARD (Ministry of Commerce & Industry, Govt. of India) Palarivattom.P.O. N H By Pass Kochi SPICES BOARD (Ministry of Commerce & Industry, Govt. of India) Palarivattom.P.O. N H By Pass Kochi 682025 Phone: 0484-2333603 Email: sbqelkochi@gmail.com REQUIREMENT OF UPS Systems and Batteries for Quality

More information

Tender No:- MTL/PUR/213/Elect/ (K)/9. 2 NEW Moulded case Circuit Breaker with O/L & S/C No 02

Tender No:- MTL/PUR/213/Elect/ (K)/9. 2 NEW Moulded case Circuit Breaker with O/L & S/C No 02 Tender No:- MTL/PUR/213/Elect/2015-16 (K)/9 Date:-26/10/2016 Type Of Bid Bidding type Bid closing On Bid Opening On EMD : LIMITED TENDER : Single Bid : 18/11/2016 at 14.00 hrs.(ist) : : As per Annexure

More information

3.6 Kwp Solar system Supply, Installation, Commissioning & Maintenance of Solar Systems to YEMAC office in HADDA street, Sana a city

3.6 Kwp Solar system Supply, Installation, Commissioning & Maintenance of Solar Systems to YEMAC office in HADDA street, Sana a city LOT1 3.6 Kwp Solar system Supply, Installation, Commissioning & Maintenance of Solar Systems to YEMAC office in HADDA street, Sana a city 1 LOT 1 3.6 Kwp Solar PV Power Solution with Battery Backup Table

More information

Umatilla Electric Cooperative Net Metering Rules

Umatilla Electric Cooperative Net Metering Rules Umatilla Electric Cooperative Net Metering Rules Version: July 2017 Umatilla Electric Cooperative NET METERING RULES Rule 0005 Scope and Applicability of Net Metering Facility Rules (1) Rule 0010 through

More information

Regional Office: Vijayapura Plot No6, Trimurthy Nagar Managuli Bypass Road, Vijayapura Diesel Generator Required on Rental Basis

Regional Office: Vijayapura Plot No6, Trimurthy Nagar Managuli Bypass Road, Vijayapura Diesel Generator Required on Rental Basis Regional Office: Vijayapura Plot No6, Trimurthy Nagar Managuli Bypass Road, Vijayapura - 586109 Diesel Generator Required on Rental Basis Bank desires to hire diesel generator on rental basis for the following

More information

TERMS AND CONDITIONS

TERMS AND CONDITIONS XXV. NET METERING A. Applicability and Availability 1. The terms Net Metering Service, Demand Charge-based Time-of- Use Tariff, Net Metering Customer, Customer, Time-of-Use Customer, Time-of-Use Tier,

More information

Solar-Wind Specific Request for Proposals

Solar-Wind Specific Request for Proposals Program Description Solar-Wind Specific Request for Proposals Power Production from Green Resources in North Carolina 04/19/2006 NC GreenPower (NCGP) is a statewide program designed to improve the quality

More information

Information Packet Kissimmee Utility Authority Customer-Owned Renewable Generation Interconnection And Net Metering Program

Information Packet Kissimmee Utility Authority Customer-Owned Renewable Generation Interconnection And Net Metering Program Information Packet Kissimmee Utility Authority Customer-Owned Renewable Generation Interconnection And Net Metering Program As part of our commitment to support renewable energy, Kissimmee Utility Authority

More information

Northeastern Rural Electric Membership Corporation Columbia City, Indiana

Northeastern Rural Electric Membership Corporation Columbia City, Indiana Page 1 of 5 SCHEDULE ADG - 1 AGGREGATED DISTRIBUTED GENERATION SERVICE I. AVAILABILITY This Aggregated Distributed Generation Schedule is available to any member in good standing of Northeastern REMC (Northeastern),

More information

شركة كهرباء محافظة القدس المساهمة المحدودة

شركة كهرباء محافظة القدس المساهمة المحدودة Our Ref: Date: Messrs. Dear Sir, Tender 22/2017 (re-bidding) 11& 33Kv Fuse Cutouts and Links You are kindly requested to bid for supply and delivery (DDP) for the medium voltage overhead line accessories

More information

TECHNICAL SPECIFICATION FOR 11 KV CAPACITOR BANK

TECHNICAL SPECIFICATION FOR 11 KV CAPACITOR BANK TECHNICAL SPECIFICATION FOR 11 KV CAPACITOR BANK MAHARASHTRA STATE ELECTRICITY DISTRIBUTION COMPANY LTD. PAGE 1 OF 7 TECHNICAL SPECIFICATION FOR 11 KV.CAPACITOR BANK 1.0 SCOPE: This specification covers

More information

File No. EL/EE/NAD/Tech/1-13/2018/822 Dated: 29/08/2018 OFFICE OF THE EXECUTIVE ENGINEER NORTH ANDAMAN DIVISION ELECTRICITY DEPARTMENT DIGLIPUR

File No. EL/EE/NAD/Tech/1-13/2018/822 Dated: 29/08/2018 OFFICE OF THE EXECUTIVE ENGINEER NORTH ANDAMAN DIVISION ELECTRICITY DEPARTMENT DIGLIPUR OFFICE OF THE EXECUTIVE ENGINEER NORTH ANDAMAN DIVISION ELECTRICITY DEPARTMENT DIGLIPUR Unique No.* Name of Work Name of Department Tender No.* Complete Mechanical works, Electrical works, Body works,

More information

24. SOLAR INCENTIVE PROGRAM II

24. SOLAR INCENTIVE PROGRAM II 24. SOLAR INCENTIVE PROGRAM II A. General California Senate Bill 1 requires publicly owned utilities that sell electricity at the retail level, to adopt, implement, and fund a solar incentive program for

More information

INVITATION FOR TENDER FOR SUPPLY OF SOLAR PV SYSTEMS

INVITATION FOR TENDER FOR SUPPLY OF SOLAR PV SYSTEMS INVITATION FOR TENDER FOR SUPPLY OF SOLAR PV SYSTEMS Sealed tender offers are invited in two separate sealed covers (Technical and Commercial offers) from eligible manufacturers/suppliers or their direct

More information

No.RSA/Nov 2013/ (R) INDIAN INSTITUTE OF TECHNOLOGY. Tender Enquiry

No.RSA/Nov 2013/ (R) INDIAN INSTITUTE OF TECHNOLOGY. Tender Enquiry No.RSA/Nov 2013/2 Phone :+91-512-597102(O) Electrical Engineering Department +91-512-598772 (R) INDIAN INSTITUTE OF TECHNOLOGY Fax: +91-512-590063 KANPUR 208016 INDIA e-mail: rsanand@iitk.ac.in Home page:

More information

Section V DC Nickel Cadmium Alkaline BATTERY

Section V DC Nickel Cadmium Alkaline BATTERY Section - 7 TECHNICAL SPECIFICATION OF 110V DC Nickel Cadmium Alkaline BATTERY TECHNICAL SPECIFICATIONS & REQUIREMENTS OF 110V DC Nickel Cadmium Alkaline Battery 7. 1 GENERAL This section of the document

More information

DISTRICT RURAL DEVELOPMENT AGENCY, SIVAGANGA SIVAGANGA DISTRICT. TENDER NOTICE NO.1287/2009/JDO Dated

DISTRICT RURAL DEVELOPMENT AGENCY, SIVAGANGA SIVAGANGA DISTRICT. TENDER NOTICE NO.1287/2009/JDO Dated DISTRICT RURAL DEVELOPMENT AGENCY, SIVAGANGA SIVAGANGA DISTRICT TENDER NOTICE NO.1287/2009/JDO Dated 12.11.2009 Sealed Tenders are invited from reputed manufacturers/ Firms for the supply of following

More information

Solar PV Projects PPA Model

Solar PV Projects PPA Model Solar PV Projects PPA Model We help you set up 'Grid Connected Solar PV Power Plants' of the size ranging from 50 kw to MW scale power projects under the PPA (Power Purchase Agreement) Model. How does

More information

THE EMPIRE DISTRICT ELECTRIC COMPANY P.S.C. Mo. No. 5 Sec. 4 1st Revised Sheet No. 23

THE EMPIRE DISTRICT ELECTRIC COMPANY P.S.C. Mo. No. 5 Sec. 4 1st Revised Sheet No. 23 P.S.C. Mo. No. 5 Sec. 4 1st Revised Sheet No. 23 Canceling P.S.C. Mo. No. 5 Sec. 4 Original Sheet No. 23 PURPOSE: The purpose of this Rider SR is to implement the solar rebate established through 393.1030

More information

045 : 2000 CEB STANDARD

045 : 2000 CEB STANDARD 045 : 2000 CEB STANDARD LOW VOLTAGE FUSE SWITCH DISCONNECTOR CEYLON ELECTRICITY BOARD SRI LANKA Specification for LOW VOLTAGE FUSE SWITCH DISCONNECTOR CEB Standard 045 : 2000 CEYLON ELECTRICITY BOARD No.

More information

Renewable Energy Interconnection Manual for Small Size Systems ( 10kW in NM 20kW in TX) Renewables and Emergent Technologies Group

Renewable Energy Interconnection Manual for Small Size Systems ( 10kW in NM 20kW in TX) Renewables and Emergent Technologies Group Renewable Energy Interconnection Manual for Small Size Systems ( 10kW in NM 20kW in TX) Renewables and Emergent Technologies Group Table of Contents 1. Introduction... 1 2. Purpose... 1 3. Customer Eligibility...

More information

TENDER FOR DG SET. Tender for DG SET. POCKET-14, SECTOR-8, PHASE-1, DWARKA, NEW DELHI Website: TENDER DOCUMENTS FOR

TENDER FOR DG SET. Tender for DG SET. POCKET-14, SECTOR-8, PHASE-1, DWARKA, NEW DELHI Website:  TENDER DOCUMENTS FOR Cost of the Tender Form - Rs.500/- (Rupees Five Hundred only) Tender Form No.MCI/TENDER DGSET/2018 Tender for DG SET MEDICAL COUNCIL OF INDIA POCKET-14, SECTOR-8, PHASE-1, DWARKA, NEW DELHI 110 077 Website:

More information

The table shown below gives the status of basic documents submitted by different tenderers.

The table shown below gives the status of basic documents submitted by different tenderers. TENDER FOR SETTING UP OF 20 kwp BUILDING INTEGRATED SOLAR PHOTOVOLTAIC POWER PLANT IN THE PROPOSED SEMINAR HALL OF THE STATE LEVEL ENERGY PARK AT SIDDU-KANU UDYAN, RANCHI, JHARKHAND The above-mentioned

More information

TECHNICAL SPECIFICATIONS FOR 11KV AIR BREAK (A.B.) SWITCHES :

TECHNICAL SPECIFICATIONS FOR 11KV AIR BREAK (A.B.) SWITCHES : TECHNICAL SPECIFICATIONS FOR 11KV AIR BREAK (A.B.) SWITCHES : 1. SCOPE : This specification covers design, manufacturing, testing at manufacturer s works, inspection, packing & delivery of 11 KV Air Break

More information

Renewable Energy Interconnection Manual for Small Size Systems ( 10kW in NM 20kW in TX) Renewables and Emergent Technologies Group

Renewable Energy Interconnection Manual for Small Size Systems ( 10kW in NM 20kW in TX) Renewables and Emergent Technologies Group Renewable Energy Interconnection Manual for Small Size Systems ( 10kW in NM 20kW in TX) Renewables and Emergent Technologies Group Table of Contents 1. Introduction... 1 2. Purpose... 1 3. Customer Eligibility...

More information

NIT No. DEERS/SSDI-JK/05 of 2018 Dated 29/08/2018 E-Tender id No: 2018_FD_ 60565

NIT No. DEERS/SSDI-JK/05 of 2018 Dated 29/08/2018 E-Tender id No: 2018_FD_ 60565 1 Phone/Fax: 0194-2494585 Government of Jammu & Kashmir, Department of Environment and Remote Sensing, SDA Housing Colony, Bemina, Srinagar, Kashmir-190018 Website: www.jkdears.com Email:dirjkers@gmail.com

More information

Municipality Generator Interconnection Application Single Meter Application Part I

Municipality Generator Interconnection Application Single Meter Application Part I Municipality Generator Interconnection Application Single Meter Application Part I New Application Revised Application A single customer interconnecting to a single meter at a single premise makes a new

More information

KAUAI ISLAND UTILITY COOPERATIVE KIUC Tariff No. 1 RULE NO. 17 NET ENERGY METERING

KAUAI ISLAND UTILITY COOPERATIVE KIUC Tariff No. 1 RULE NO. 17 NET ENERGY METERING Third Revised Sheet 55a Cancels Second Revised Sheet 55a A. ELIGIBLE CUSTOMER-GENERATOR RULE NO. 17 NET ENERGY METERING Net energy metering is available to eligible customer-generators, defined as, permanent

More information

REQUEST FOR PROPOSAL

REQUEST FOR PROPOSAL Palabora Copper REQUEST FOR PROPOSAL SUPPLY AND DELIVERY OF PIPES, FITTINGS AND FLANGES TO PALABORA COPPER TENDER NUMBER: RFP.PC.2015/144 PART 1 PROPOSAL INFORMATION AND CONDITIONS Page 1 Supply and Delivery

More information

Comparison of Indian Electricity Rules, 1956 Vs CEA (Measures relating to Safety and Electric Supply) Regulations, 2010

Comparison of Indian Electricity Rules, 1956 Vs CEA (Measures relating to Safety and Electric Supply) Regulations, 2010 1 of 5. Comparison of Indian Electricity Rules, 1956 Vs CEA (Measures relating to Safety and Electric Supply) Regulations, 2010 2 Definitions 2 Not seen the definition for Inspector. But with, - Qualifications,

More information

40kW (and under) Solar/Inverter Installations Generation Interconnection Application to Minnesota Power

40kW (and under) Solar/Inverter Installations Generation Interconnection Application to Minnesota Power 40kW (and under) Solar/Inverter Installations Generation Interconnection Application to Minnesota Power WHO SHOULD FILE THIS APPLICATION: Anyone expressing interest to install generation which will interconnect

More information

HARYANA POWER GENERATION CORPORATION LIMITED Regd. Office C-7, Urja Bhawan, Sector-6, Panchkula Corporate Identity Number: U45207HR1997SGC033517

HARYANA POWER GENERATION CORPORATION LIMITED Regd. Office C-7, Urja Bhawan, Sector-6, Panchkula Corporate Identity Number: U45207HR1997SGC033517 HARYANA POWER GENERATION CORPORATION LIMITED Regd. Office C-7, Urja Bhawan, Sector-6, Panchkula Corporate Identity Number: U45207HR1997SGC033517 Website: www.hpgcl.org.in E-mail- ceplg@hpgcl.org.in EXPRESSION

More information

RULE 21 GENERATING FACILITY INTERCONNECTION APPLICATION SMUD s Distribution System - (SMUD FORM 2655)

RULE 21 GENERATING FACILITY INTERCONNECTION APPLICATION SMUD s Distribution System - (SMUD FORM 2655) - (SMUD FORM 2655) A. Applicability: This Generating Facility Interconnection Application (Application) shall be used to request the interconnection of a Generating Facility to Sacramento Municipal Utility

More information

Microgeneration Installation Standard: MCS

Microgeneration Installation Standard: MCS Microgeneration Installation Standard: MCS 001-01 MCS Contractor Certification Scheme Requirements Part 1: Requirements for MCS Contractors Issue 3.1 This Microgeneration Installation Standard is the property

More information

INVITATION FOR QUOTATION. TEQIP-III/2017/uiet/Shopping/35

INVITATION FOR QUOTATION. TEQIP-III/2017/uiet/Shopping/35 INVITATION FOR QUOTATION TEQIP-III/2017/uiet/Shopping/35 09-Jan-2018 To, Sub: Invitation for Quotations for supply of Goods Dear Sir, 1. You are invited to submit your most competitive quotation for the

More information

Maharashtra Electricity Regulatory Commission (Renewable Purchase Obligation, Its. Regulations, 2016 STATEMENT OF REASONS

Maharashtra Electricity Regulatory Commission (Renewable Purchase Obligation, Its. Regulations, 2016 STATEMENT OF REASONS MAHARASHTRA ELECTRICITY REGULATORY COMMISSION World Trade Centre, Centre No.1, 13th Floor, Cuffe Parade, Mumbai 400 005 Tel. 022 22163964/65/69 Fax 22163976 Email: mercindia@mercindia.org.in Website: www.mercindia.org.in

More information

CHAPTER 25. SUBSTANTIVE RULES APPLICABLE TO ELECTRIC SERVICE PROVIDERS.

CHAPTER 25. SUBSTANTIVE RULES APPLICABLE TO ELECTRIC SERVICE PROVIDERS. 25.211. Interconnection of On-Site Distributed Generation (DG). (a) (b) (c) Application. Unless the context indicates otherwise, this section and 25.212 of this title (relating to Technical Requirements

More information

Technical Specification. for. Supply, installation and commissioning of Diesel Generators for UNDP

Technical Specification. for. Supply, installation and commissioning of Diesel Generators for UNDP United Nations Development Programme Recovery and Crisis Prevention برنامج األمم المتحدة اإلنمائي Iraq Technical Specification for Supply, installation and commissioning of Diesel Generators for UNDP February

More information

SSEFITAPP 2012_08_07 v2.1. FeeD-In TArIFF APPlICATIon ForM

SSEFITAPP 2012_08_07 v2.1. FeeD-In TArIFF APPlICATIon ForM FeeD-In TArI APPlICATIon ForM If you wish to register for the Feed-in Tariff (FIT) Scheme with SSE Energy Supply Ltd as your FIT provider, please complete the following application form. Please read and

More information

Policy Bulletin No. 25 Net Metering. Public Utility District No. 1 of Klickitat County 1313 South Columbus Goldendale, WA 98620

Policy Bulletin No. 25 Net Metering. Public Utility District No. 1 of Klickitat County 1313 South Columbus Goldendale, WA 98620 Policy Bulletin No. 25 Net Metering Public Utility District No. 1 of Klickitat County 1313 South Columbus Goldendale, WA 98620 Interconnection Standards For Residential Net Energy Metering With Electric

More information

London Hydro Connection Checklist

London Hydro Connection Checklist London Hydro Connection Checklist Applicants should be aware not to incur expenses prior to London Hydro approving the connection of the facility to the grid. Payment of Connection Fee: $1000 plus HST

More information